Professional Documents
Culture Documents
เเคตตาล็อค 2024
เเคตตาล็อค 2024
Purge
Air in 1mtr.
Power
Supply Receiver
Danger
Unit (PSU)
Mains Power In
Inputs / Outputs
It is vital that all measurements are made on the same basis. Attempting to
make this calculation using an actual hot wet gas flow in m/s and a normalised
gas concentration in mg/Nm³ will produce significant errors.
Operating Principle
The method used is similar in principle to the technique of flow measurement by the injection of chemical dye or
radioactive tracers, where the velocity is derived from the transport time of the tracer between two measuring points a
known distance apart. Instead of an artificial tracer being added, the naturally occurring turbulence of the gas stream is
used as the tracer.
This flow turbulence causes fluctuations to occur in infrared radiation emitted by the gas. This continuously variable
turbulent pattern is monitored by two infra red detectors mounted typically 1m apart along the direction of gas flow. An
electronic correlation technique is used to continuously compare the two detector signals to determine the time delay
between them imposed by the gas velocity.
Flow L Typical signals from the sensor A and B are shown here.
The signal from sensor B shows a strong similarity to that
from sensor A but is delayed by a time t, the time taken for
Sensor A Sensor B
the gas to flow from point A to point B
A(t) B(t)
Continuous determination of the detector signal time
delay by the signal processor unit produces a continuous
measurement of gas velocity since:
A(t)
Tmax Tmax
Velocity V = L/t, where L is the distance between two
sensors.
B(t)
Technical Specifications
Operating principle Infrared correlation
Measuring range 1m/s to 50m/s
Measuring units m/s, m³/s
Resolution 0.1m/s
Detectors Lithium tantalite pyroelectric
Receiver separation 0.5mtr to 1mtr
Pathlength Suitable for 0.5mtr to 15mtr of duct/stack diameter
Accuracy +/-2% of measurement
Linearity +/-1% of measurement
Response time (T90) Less than 10 seconds
Overall drift Less than 0.1m/s per month
Averaging 4 rolling averages selectable from 10 seconds to 30 days
Calibration Auto low and high span check (US EPA compliant)
Ambient temperature Receiver units: -20°C to +70°C, SPU/PSU/DDU:- -20°C to +55°C
Flue gas temperature 55°C or above flue gas due point, no upper temperature limit
Construction Corrosion resistant epoxy coated aluminium housing sealed to IP66
Outputs 2 x 4-20mA, isolated, 500Ω load max, fully site configurable
RS 485 modbus interface
2 x volt-free SPCO alarm contacts, 50V, 1A max site configurable
1 x volt-free SPCO contact, 50V, 1A max, for data valid signal
Display 2 line x 32 character alpha–numeric LCD display with 4 key keypad
Power Supply Mains 110 / 220 VAC , single phase, 50Hz +/-10% tolerance – 20VA
Air purging Continuous clean and dry plant compressed air 0.5LPS@4bar pressure
Compliances EMC - 89/336/EEC directive compliant
Low Voltage - 73/23/EEC directive compliant
EN14181 QAL1 - TUV Certified
Overall Dimensions – VCEM5100 Receiver Unit and Side Flange
310
1000
Ø76 Ø165
Transceiver
(wt. 8kg)
230 230
Danger
160 110
Opp 106th Milestone B-85, Phase II, Chakan Indl Area A-34/35, MIDC H Block
Bombay Poona Road Sawardari, Chakan, Tal. Khed Pimpri, Pune - 411 018. INDIA.
Kasarwadi, Pune - 411 034. INDIA Dist. Pune - 410 501. INDIA Tel : 91(0)20-27442020, 39851199
Tel : 91(0)20-27145595, 39858555 Tel : 91(0)2135-393400 Fax : 91(0)20-27442040
Forbes Marshall Fax : 91(0)20-27147413
Krohne Marshall CIN No.: U28996PN1985PTC037806
Forbes Marshall Arca Email : environ@forbesmarshall.com, ccmidc@forbesmarshall.com www.forbesmarshall.com
Codel International © All rights reserved. Any reproduction or distribution in part or as a whole without written permission of Forbes Marshall Pvt Ltd, its associate
Forbes Solar companies or its subsidiaries (“FM Group”) is prohibited.
Information, designs or specifications in this document are subject to change without notice. Responsibility for suitability, selection, installation, use,
Forbes Vyncke operation or maintenance of the product(s) rests solely with the purchaser and/or user. The contents of this document are presented for informational
Forbes Marshall Steam Systems purposes only. FM Group disclaims liabilities or losses that may be incurred as a consequence of the use of this information.
DOC#FMCI/1218/1305/V3.R0