Professional Documents
Culture Documents
Flowsic100 Full
Flowsic100 Full
FLOWSIC100
FLOWSIC100
FLOWSIC100
Continuous Process
FLOWSIC600
Emission
Monitoring FLOWSIC100 FLOWSIC150
Flare Natural gas + Carflow FLOWSIC200
Process
industry Exhaust gas
Process control measurement Air velocity
Automotive measurement
industry Traffic tunnels
Measuring task
Major applications:
: CEMS (continuous emission monitoring)
: Process control
- Flare Gas
- Hydrocarbon processing
- Blast furnace gas
- and many more
Inner channel pressure max.: -0,5 ... +0,3 barg (+16 barg)
Measurement principle
L 1 1
vp = -
2 cos( ) t AB t BA
L 1 1
c= +
Qia =v A(C ) Speed of sound
2 t AB t BA
stack
35
30
25
flow velocity [ m/s]
20
Profile measurement
axis
15
0
-3, 5 -3 -2, 5 -2 -1, 5 -1 -0, 5 0 0,5 1 1,5 2 2,5 3 3,5
Calibration
: Profile measurements,
: net point measurement according
VDI2066
Calibration
▪ Calculation of calibration
coefficients by using a regression
analysis
v A = Cv 2 v 2 + Cv1 v + Cv 0
Check Cycle
Check Cycle
Check Cycle
: No purge air
FLOWSIC100 PR
FLOWSIC100 M
FLOWSIC100 S
FLOWSIC100 H
: SICK : NEP 2009 FLOWSIC100
Product family FLOWSIC100
Outlet of
cooling air
Transducer
Inlet of
cooling air
FLOWSIC100 M-AC
FLOWSIC100 H-AC
FLOWSIC100 PM
FLOWSIC100 PH
FLOWSIC100 PH-S
D > 10 ft ?
Internal cooled versions
Y N
Y N
FS100 PR
FS100 PR FS100 PR FS100 M
FS100 H FS100 S*
FS100 PR
*) D < 1,7 m, no certification needed
Sender/Receiver unit
Transducer
: Air-Cooled (internal)
Connection box
: Robust design
: Interface options
- Ethernet TCP/IP
- Profibus DP
- Modbus RS485
: Display module
- display of measured values
- status information
- configuration settings for commissioning of device
MCU
MEPAFLOW
Flow profile
Target Industries
: Power Generation
: Iron and steel manufacturing
: Cement industry
: Pulp and paper
: Waste incinerators
Device: FLOWSIC100 H
Measuring task:
: Measurement of flow rate
Application details:
: Stack diameter inside: 8,5m (28 ft.)
: Flue gas temperature: 182°C (360°F)
: Dust concentration: <10mg/m³ (<0,3 mg/ft³)
: Gas velocity: 10m/s (33 ft/s)
Device: FLOWSIC100 PR
Measuring task:
: Measurement of flow rate
Application details:
: Stack diameter inside: 7,8m (26 ft)
: Flue gas temperature: 165°C (330 °F)
: Dust concentration: <50mg/m³ (<1.4 mg/ft³)
: Gas velocity: 12m/s (39 ft/s)
Measuring task:
: Measurement of flow rate
Application details:
: Stack diameter inside: 3.2m (10.5 ft)
: Flue gas temperature: 70°C (158 °F) wet gas
: Gas velocity: 10m/s (33 ft/s)
Application details:
: Channel diameter: 3,5 m (11,5 ft)
Measuring task:
Controlling of primary air to reduce the nitrogen
oxides. This application requires a reliable result
of measurement for the controlling of the primary
air flap
Application details:
: channel diameter: 0,7 m (2,3 ft)
: temperature: 313 °C (595 °F) The dust was collected from the
: flow velocity: ~25 m/s (82 ft/s) FLOWSIC housing after 12 month
: over pressure: 34 mbar (0.5 psi) without maintenance (here type PMD).
Measuring task:
: Measuring of exhaust gas from copper smelting
process for the sulphuric acid production.
Application details:
: Channel diameter: 3,4 m (11,2 ft)
Our solution:
Advantages
: Lower costs for installation, maintenance, consumables !
: No dew point underruns - no corrosion problems !
: No intake of cooling air in the measured medium
Advantage
: Probe version can save costs at large stack diameters because a
expensive 2nd platform constructions isn’t needed !
All CEMS devices are equipped with long lasting titanium transducers. For
failure.
Advantage
: High durability also in wet gas conditions
: Single transducer exchange means lower cost and shorter repair time !
Advantage
: Multiple choice for individual application conditions possible
: Ultrasonic technology on highest level of development for long life
measurement and high application safety
: Flange connection with bolting circle acc. to ANSI CL150 for installation in
existing flanges
Advantage
: Easy exchange of existing installations
: Plug and play
Technology features
No Moved parts
: Differential measurement
: No loss of pressure
p2
: No purge air
: SICK MAIHAK - the german technology leader with more than 25 years
of experience in ultrasonic technology
Principle
: Measurement of total pressure on the front side of
the probe + static pressure on the back of the
probe
Advantages
: Best known technology
: Broad installed base in the field
: Simple construction and manufacturing
Weaknesses
: Difficult to install at large stacks
: Sensitive to contamination and blockages
: High dust concentration means high service expenditures
: No measurement possible close to zero, inaccurate at low gas velocities
Advantages
: Nothing known in flow
Disadvantages
: Old, heavy technology
: Purged units only
: No titanium transducers
: Not reliable
: No position in the US