FLOWSIC100.

The ultrasonic gas flow measurement system.


Introduction

FLOWSIC100

TÜV certified acc. to 13., 17., 27. BImSchV


and TA-Luft

: SICK : NEP 2009 FLOWSIC100


Introduction

SICK - German technology leader in ultrasonics

FLOWSIC100
FLOWSIC100
Continuous Process
FLOWSIC600
Emission
Monitoring FLOWSIC100 FLOWSIC150
Flare Natural gas + Carflow FLOWSIC200
Process
industry Exhaust gas
Process control measurement Air velocity
Automotive measurement
industry Traffic tunnels

: SICK : NEP 2009 FLOWSIC100


Content

Training course objectives

: Getting an overview of FLOWSIC100


- different device types and specification
- measuring task
- functional principle

: Advising customers for his application


- introduce the FLOWSIC100, features + benefits
- analyse the application conditions
- give recommendations for installation + use of the device

: Make device configurations and quotations


- choose the suitable device type configuration
- use price list FLOWSIC100

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Measuring task

Measurement of gas velocity in ducts, chimneys and pipes


Measured value in m/s [ft/sec] and calculation of volume flow in
m³/h [ascf/min] in actual conditions

Major applications:
: CEMS (continuous emission monitoring)
: Process control
- Flare Gas
- Hydrocarbon processing
- Blast furnace gas
- and many more

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Application ranges of FLOWSIC100

Inner channel diameter min. - max.: 0,15 ...13 m

Medium temperature: -40 ... + 450 °C

Inner channel pressure max.: -0,5 ... +0,3 barg (+16 barg)

Dust concentration (load) max.: 100 g/m³ s. c.

Ambient Temperature min. ... max.: -40 ... +60 °C

Cable length between control unit


and sender/receiver unit max: 1.000 m

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Measurement principle

Detection of transit time


L
t AB =
c + v p cos( )
Transit times:
L
tBA =
c − v p cos( )

L  1 1 
vp =  - 
2 cos( )  t AB t BA 

vp - average velocity on measuring path


tAB,tBA - transit times
L - length of measuring path
a - installation angle to flow axis
c - speed of sound

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Calculation of volume flow in actual conditions

L 1 1 
c=  + 
Qia =v A(C ) Speed of sound
2  t AB t BA 

Qi.a.= volume flow [m³/h i.a.] or [aft³/min]


Ultrasonic „add” value for:
v = velocity [m/s] or [ft/s]
Calculation of gas temperature
A = duct area [m²] or [ft²]
Calculation of mass flow
C = calibration- (or profile)-factor
Calculation of molecular weight
Diagnostics

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Calibration Probe measuring point Measurement


axis Cross-Stack

stack

35

30

25
flow velocity [ m/s]

20
Profile measurement
axis
15

Practical profile with


unsymmetrical inlet 10

0
-3, 5 -3 -2, 5 -2 -1, 5 -1 -0, 5 0 0,5 1 1,5 2 2,5 3 3,5

distance relative to the stack centre [m]

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Calibration

: Profile measurements,
: net point measurement according
VDI2066

e.g. with Gravimat SHC500

Rectangular ducts Circular ducts

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Calibration
▪ Calculation of calibration
coefficients by using a regression
analysis
v A = Cv 2  v 2 + Cv1  v + Cv 0

Flowsic measurement v [m/sec]

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Check Cycle

Zero point check (send & receive via internal loop)


: A sender signal is internally sent back and picked up as a receiver signal
and is amplified, demodulated and evaluated.
: This check covers the entire system, including the transducers. If everything is
working correctly, the zero point of the system is obtained.
: Deviations over 0.25 m/s (0.8 ft/s) cause a warning message. In this case
transducer and electronics have to be checked separately.

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Check Cycle

Span test (send & receive with internal time delay)


: send & receive via internal loop
: A time difference, corresponding to 70 % of full scale is added to the
measurement.
: If all system components are functional, the result of the measurement equals
the calculated time delay.
: In case of deviations, a malfunction message occurs.

: SICK : NEP 2009 FLOWSIC100


Basics of FLOWSIC100

Check Cycle

: SICK : NEP 2009 FLOWSIC100


Product family FLOWSIC100

FLOWSIC100 standard types

: Titanium transducers as standard

: Medium gas temperature -40 ... +260 °C

: Medium and high power version

: Single probe version

: No purge air

: SICK : NEP 2009 FLOWSIC100


Product family FLOWSIC100

FLOWSIC100 standard types

FLOWSIC100 PR

FLOWSIC100 M

FLOWSIC100 S
FLOWSIC100 H
: SICK : NEP 2009 FLOWSIC100
Product family FLOWSIC100

FLOWSIC100 AC-types (internal air-cooled types)

: Patented internal air-cooling

: Titanium transducers as standard

: Medium gas temperature -40 ... +450 °C

: Medium power and high power version,

single probe version (on request)

: No intake of cool air in the duct

: SICK : NEP 2009 FLOWSIC100


Product family FLOWSIC100

FLOWSIC100 AC-types (internal air-cooled types)

Outlet of
cooling air
Transducer

Inlet of
cooling air

: SICK : NEP 2009 FLOWSIC100


Product family FLOWSIC100

FLOWSIC100 AC-types (internal air-cooled types)

MCU Control unit


with integrated blower unit

: SICK : NEP 2009 FLOWSIC100


Product family FLOWSIC100

FLOWSIC100 AC-types (internal air-cooled types)

FLOWSIC100 M-AC
FLOWSIC100 H-AC

: SICK : NEP 2009 FLOWSIC100


Product family FLOWSIC100

FLOWSIC100 purged types

: Titanium transducers as standard

: Medium gas temperature -40 ... +450 °C

: Medium power and high power version

: For applications with wet and sticky dust only

FLOWSIC100 PM
FLOWSIC100 PH
FLOWSIC100 PH-S

: SICK : NEP 2009 FLOWSIC100


Product family FLOWSIC100

Modular concept - the CEMS decision tree


More than 260 °C (500
°F)?
Y N

D > 10 ft ?
Internal cooled versions
Y N

One-sided inst. only ? One-sided


inst. only ?
Y N

Y N

FS100 PR
FS100 PR FS100 PR FS100 M
FS100 H FS100 S*
FS100 PR
*) D < 1,7 m, no certification needed

: SICK : NEP 2009 FLOWSIC100


System components FLOWSIC100

: SICK : NEP 2009 FLOWSIC100


System components FLOWSIC100

Sender/Receiver unit

: Calculation of measured values (gas velocity, gas volume flow) in electronics of


sender/receiver units
: No transfer of run-time data to evaluation unit (exception: data for signal diagnosis)
: “Master-Slave“ concept (master sensor triggers slave-sensor)

: SICK : NEP 2009 FLOWSIC100


System components

Sender/Receiver units - Standard type

Electronic unit Connection M Duct probe Transducer

NL = 200, 350, 550


Connection for cable

Example FLSE100-M (Medium Power)

: SICK : NEP 2009 FLOWSIC100


System components

Sender/Receiver units - Standard type

Electronic unit Connection PR/PR-AC Duct probe

Transducer

NL = 350, 550, 750


Connection for cable

Example FLSE100-PR (Probe version)

: SICK : NEP 2009 FLOWSIC100


System components

Sender/Receiver units - Ultrasonic transducers

Transducer frequency Low frequency Medium frequency High frequency

Power High Power Medium Power Small size transducer

Material Stainless steel Stainless steel Stainless steel


Titanium Titanium Titanium
Hastelloy Hastelloy
Suitable for Large duct diameter, Medium duct Short measuring
High dust load diameters, medium distance, low dust
applications dust

Stainless steel: Use for dry and non-aggressive gas


Titanium: Use for moisture gas with aggressive components
Hastelloy: Use for moisture gas with high aggressive components (HF, HCL)

: SICK : NEP 2009 FLOWSIC100


System components

Sender/Receiver units - Configuration

Example: FLSE100-MAC 35SSTI

: Medium Power Transducer

: Air-Cooled (internal)

: Nominal probe length 350 mm

: Probe material Stainless Steel

: Transducer material Titanium

: SICK : NEP 2009 FLOWSIC100


System components

Flange with tube / Connecting cables

: Different nominal lengths


: Different materials
- carbon steel
- stainless steel

: Connection cable Master 5m / 10m / 50m


: Connection cable Slave 5m / 10m / 50 m

: SICK : NEP 2009 FLOWSIC100


System components

Connection box

: for connection of “Master” and “Slave” connection cable


: for single-probe version optionally

: SICK : NEP 2009 FLOWSIC100


System components

Multi Control Unit (MCU)

: Main function is I/O - flexible + modular expandable

acc. to customer requirements

: Robust design

: Display (uniform for SICK MAIHAK sensors)

: 19” version available

: SICK : NEP 2009 FLOWSIC100


System components

Multi Control Unit (MCU)- details of function

: I/O (Base configuration)


- 1 x analog output
- 2 x analog input
- 5 x digital output (relay contacts)
- 4 x digital input
- Interface USB 1.1, RS232
(for service and parameterization)
- RS485 for data communication with s/r units

: SICK : NEP 2009 FLOWSIC100


System components

Multi Control Unit (MCU)- I/O options

: Analog and digital modules (each with 2 in- or outputs)


- analog output modules (up to 4)
- analog input modules (up to 4)
- digital output module (2 x changeover contacts)

: Interface options
- Ethernet TCP/IP
- Profibus DP
- Modbus RS485

: SICK : NEP 2009 FLOWSIC100


System components

Multi Control Unit (MCU)

: Display module
- display of measured values
- status information
- configuration settings for commissioning of device

: SICK : NEP 2009 FLOWSIC100


System components

Multi Control Unit (MCU)

: Multifunctional use for flow- and dust measurement technology


- optional 2-path measurement or connection of dust sensor possible

FLSE100 FLSE100 FLSE100 FLSE100


Master Slave Master Slave

MCU

: SICK : NEP 2009 FLOWSIC100


System components

Purge air unit (for external purged types only)

: Not for standard types !

: Selection of type depends on inner


channel pressure

: Two different types


- 2BH13 up to +30 mbar (g)
- 2BH14 >+30 mbar ... +100 mbar (g)

: SICK : NEP 2009 FLOWSIC100


System components

User software SOPAS Engineeringtool (SOPAS ET)

: Same user interface for all sensors of Division 03 / harmonization of

SICK MAIHAK CEMS technology on a shared software platform

: Extended and improved functionality compared with previous

MEPAFLOW

: SICK : NEP 2009 FLOWSIC100


System components

SOPAS ET - Main configurations for commissioning

: SICK : NEP 2009 FLOWSIC100


Certifications

Certifications for CEMS

: TÜV certified acc. to european regulations


- EU directive 2001/80/EC
- EU directive 2000/76/EC for waste incineration plants
- 27. BImSchV, TA-Luft
- 6 months maintenance interval proofed by a 12 months field test

: Compliant to requirements of US regulation US EPA 40 CFR pt.60 and 75

: MCERTS and GOST certification pending

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

Flow profile

Important: Allow for long undisturbed inlet!

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

Large duct diameters / platform construction

Recommendation: Installation at 60 ° saves costs

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

Large duct diameters / platform construction

: Application for probe version


FLOWSIC100 PR

: Where a platform is available


from one side only

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

Single probe version


FLOWSIC100 PR

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

: Why is the single-probe version good as well?


- For it doesn’t matter that much
- if there is just one probe.
Minimum distance to stack wall were
the local velocity is representative for
- As long as you don’t measure the flow profile

too close to the wall.

Close to stack wall the


gas velocity goes to
zero

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

Installation of flange with pipe

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

Installation of flange with pipe

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

Installation of flange with pipe

Flange with pipe mounted on brick or concrete duct

: SICK : NEP 2009 FLOWSIC100


Mounting and installation

Installation of purged S/R units

: SICK : NEP 2009 FLOWSIC100


Applications

Target Industries

: Power Generation
: Iron and steel manufacturing
: Cement industry
: Pulp and paper
: Waste incinerators

: SICK : NEP 2009 FLOWSIC100


Applications

CEMS application requirements

: Large duct diameters = long measuring distances

: Expected measuring accuracy appr. ± 2-5 %

: Gases with low dust load

: Saturated and dry gases

: SICK : NEP 2009 FLOWSIC100


Applications

Power Plant - CEMS stack measurement

Device: FLOWSIC100 H

Measuring task:
: Measurement of flow rate

Application details:
: Stack diameter inside: 8,5m (28 ft.)
: Flue gas temperature: 182°C (360°F)
: Dust concentration: <10mg/m³ (<0,3 mg/ft³)
: Gas velocity: 10m/s (33 ft/s)

: SICK : NEP 2009 FLOWSIC100


Applications

Power Plant - CEMS stack measurement


Applications where access from one
side is possible only

Device: FLOWSIC100 PR

Measuring task:
: Measurement of flow rate

Application details:
: Stack diameter inside: 7,8m (26 ft)
: Flue gas temperature: 165°C (330 °F)
: Dust concentration: <50mg/m³ (<1.4 mg/ft³)
: Gas velocity: 12m/s (39 ft/s)

: SICK : NEP 2009 FLOWSIC100


Applications

Waste incineration plant - CEMS stack measurement


Device: FLOWSIC100 H

Measuring task:
: Measurement of flow rate

Application details:
: Stack diameter inside: 3.2m (10.5 ft)
: Flue gas temperature: 70°C (158 °F) wet gas
: Gas velocity: 10m/s (33 ft/s)

: SICK : NEP 2009 FLOWSIC100


Applications

Process application - controlling of water injection


Device: FLOWSIC100 PH-S
Measuring task:
: Controlling of the volume flow after the last
cyclone filter for the controlling of the water
injection of flow rate

Application details:
: Channel diameter: 3,5 m (11,5 ft)

: Channel material: carbon steel

: Temperature: up to 400°C (750 °F)

: Flow velocity: ~20 m/s (65 ft/s)

: Dust concentration: ~100 g/m³ (43.7 gr/ft³)

: SICK : NEP 2009 FLOWSIC100


Applications

Process application - combustion air


Device: FLOWSIC100 M-AC

Measuring task:
Controlling of primary air to reduce the nitrogen
oxides. This application requires a reliable result
of measurement for the controlling of the primary
air flap

Application details:
: channel diameter: 0,7 m (2,3 ft)

: channel material: carbon steel

: temperature: 313 °C (595 °F) The dust was collected from the
: flow velocity: ~25 m/s (82 ft/s) FLOWSIC housing after 12 month

: over pressure: 34 mbar (0.5 psi) without maintenance (here type PMD).

: SICK : NEP 2009 FLOWSIC100


Applications

Process application - Copper industry


Device: FLOWSIC100 PH-S

Measuring task:
: Measuring of exhaust gas from copper smelting
process for the sulphuric acid production.

Application details:
: Channel diameter: 3,4 m (11,2 ft)

: Dust content: ~ 1.000mg/m³

: Temperature: ~ 400 °C (752 °F)

: Flow velocity: ~ 25 m/s (82 ft/s)

: Overpressure: 100 mbar (1.45 psi)

: Acid dew point : 180°C (356 °F)

: SO2 content: 10 ... 15 g/m³


: SICK : NEP 2009 FLOWSIC100
Applications

Process application - Copper industry

What problems do we had to solve ?


: Acid dew point at 180 °C (356 °F)
: High aggressive gas composition
: High dust load
: The cold air purge drop down the the
flue gas temperature below the
acid dew point at the point of intersection.

Our solution:

: The transducer and probe tube made in Hastelloy.


: Use of purge air heaters

: SICK : NEP 2009 FLOWSIC100


Content

: 1. Introduction / training course objectives


: 2. Basics
: 3. Product family FLOWSIC100
: 4. System components
: 5. Certifications
: 6. Mounting and installation
: 7. Applications
: 8. Special solutions
: 9. Advantages of FLOWSIC100
: 10. Features and highlights
: 11. Competitive comparison
: 12. Conclusion
: 13. Short training

: SICK : NEP 2009 FLOWSIC100


Special Features of FLOWSIC100

1. No purge air required

FLOWSIC100 operates at gas temperatures up to 260 °C without purge air and

above with a innovative internal cooling up to 450 °C.

Advantages
: Lower costs for installation, maintenance, consumables !
: No dew point underruns - no corrosion problems !
: No intake of cooling air in the measured medium

: SICK : NEP 2009 FLOWSIC100


Special Features of FLOWSIC100

2. Probe version available

Probe version FLOWSIC100 PR allows installation from one side only if

access isn‘t possible from two sides.

Advantage
: Probe version can save costs at large stack diameters because a
expensive 2nd platform constructions isn’t needed !

: SICK : NEP 2009 FLOWSIC100


Special Features of FLOWSIC100

3. High performance titanium transducers as a standard

All CEMS devices are equipped with long lasting titanium transducers. For

extrem aggressive conditions Hastelloy solutions are available.

SICK technology allows the exchange of a single transducer in case of

failure.

Advantage
: High durability also in wet gas conditions
: Single transducer exchange means lower cost and shorter repair time !

: SICK : NEP 2009 FLOWSIC100


Special Features of FLOWSIC100

4. High application safety and flexibility

FLOWSIC100 technique is based on SICK‘s experience in ultrasonic

technology for more than 25 years.

Advantage
: Multiple choice for individual application conditions possible
: Ultrasonic technology on highest level of development for long life
measurement and high application safety

: SICK : NEP 2009 FLOWSIC100


Special Features of FLOWSIC100

5. Easy exchange of Teledyne installations in the US market

FLOWSIC100 is delivered acc. to US standards:

: Flange connection with bolting circle acc. to ANSI CL150 for installation in

existing flanges

: Mounting material 5/8“ screws + nuts

: 19“ version of MCU available

Advantage
: Easy exchange of existing installations
: Plug and play

: SICK : NEP 2009 FLOWSIC100


Features and highlights

Technology features
No Moved parts
: Differential measurement

: Results are independent of gas temperature,


pressure, density and contamination of transducers

: High measuring accuracy even at gas velocity


near zero
No loss of pressure

: No loss of pressure
p2

: No mechanical moving parts


p1
: Easy installation : p1> p2

: Low maintenance effort

: SICK : NEP 2009 FLOWSIC100


Features and highlights

Why is ultrasound the best technology ?

Marginal contact to the measured medium


: That means:
- no contamination
- always highest measuring precision !

Reliable and accurate measurement even under extremely difficult conditions


- stack diameters above 3 m,
- wet gas,
- low gas velocity (even close to point zero),
- turbulences

: SICK : NEP 2009 FLOWSIC100


Features and highlights

Special features of FLOWSIC100

: Long lasting titanium transducers as a standard

: No purge air

: Easy installation and commissioning

: Single probe version for one-side installation available

: 2-path solution available

: SICK : NEP 2009 FLOWSIC100


Features and highlights

: Modular concept allows optimal solutions for individual


application conditions

: FLOWSIC100 - well established products with all


advantages of advanced ultrasonic technology

: SICK MAIHAK - the german technology leader with more than 25 years
of experience in ultrasonic technology

: SICK : NEP 2009 FLOWSIC100


Competitive comparison

Conventional technology - Differential pressure

Principle
: Measurement of total pressure on the front side of
the probe + static pressure on the back of the
probe

: Pressure differences represents a measurement


for the gas velocity

: SICK : NEP 2009 FLOWSIC100


Competitive comparison

Conventional technology - Differential pressure

Advantages
: Best known technology
: Broad installed base in the field
: Simple construction and manufacturing

Weaknesses
: Difficult to install at large stacks
: Sensitive to contamination and blockages
: High dust concentration means high service expenditures
: No measurement possible close to zero, inaccurate at low gas velocities

: SICK : NEP 2009 FLOWSIC100


Competitive comparison

Ultrasonic technology - Competitors


DURAG / Model D-FL200

Advantages
: Nothing known in flow

Disadvantages
: Old, heavy technology
: Purged units only
: No titanium transducers
: Not reliable
: No position in the US

: SICK : NEP 2009 FLOWSIC100


Content

: 1. Introduction / training course objectives


: 2. Basics
: 3. Product family FLOWSIC100
: 4. System components
: 5. Certifications
: 6. Mounting and installation
: 7. Applications
: 8. Special solutions
: 9. Advantages of FLOWSIC100
: 10. Features and highlights
: 11. Competitive comparison
: 12. Conclusion
: 13. Short training

: SICK : NEP 2009 FLOWSIC100


Conclusion

Summary - What you should know after the training course

: Measuring task and function of the FLOWSIC100

: Different device types and main specification

: How to advise a customer for a application

: Analyse application conditions and configure the suitable FLOWSIC100

: Prepare quotations of FLOWSIC100

: SICK : NEP 2009 FLOWSIC100


: Thank you for your attention.