20-SP3>#spsy|/home/spsy> cd /home/s/src/param/ui_supply/config/
/home/s/src/param/ui_supply/config
ad1oe<OEDAS-PROD-2.20-SP3>#spsy|config> ls
L2 cnsd ethernetmodem.prop gsm.properties
lssd_config serialmodem.prop stmv vald
L2_nco consolemodem.properties fotm hopf medi
sms uipcoi vaop
acop dsBase_config fotm_text lampcheck* notesd
smsgw ulsd_config
agcsd_config dsBase_gdw/ gong lidi
oplsd_config* spmsd_config vadi
ad1oe<OEDAS-PROD-2.20-SP3>#spsy|config> vi gong
ad1oe<OEDAS-PROD-2.20-SP3>#spsy|config> cat gong
/* SPECTRUM: CONF
* Copyright (C) Siemens AG 1992-2016 All Rights Reserved.Confidential
* GONG configuration
*
* $NewRev$
* 220111 Muhsin KCETAS Gong Settings for MeCl15 and MeCl21
* 171226 Hakan KCETAS Gong Settings for MeCl13 and MeCl14
* 171128 Hakan KCETAS Gong Settings has reconfigured only for MeCl1 and MeCl2
* 161007 Mayh sp7-scada_v02.10_fu_ems00078190_gong_timer_vie
* 150717 Mayh sp7-scada_v01.30_df_ems00063916_gong_sp4_features_vie
* 140127 Mayh bf-ui_4_gongExtensions_47
* - MessageForAllGongs added
* - CentralGongMessage added
* 140115 Mayh bf-ui_GongMessageForAllGongs_47
* MessageForAllGongs added
* 130712 Mayh bf-ui_44901_gong_AutoEnableByTimer_47:
* config parameters added
* 100416 Mayh: ad-gong_AutoEnableByTimer_46: add gong messages
* 100324 Mayh: ad-gong_AutoEnableByTimer_46: redesign 'AutoEnable'
* gong status message (enabled/disabled)
* 100217 spc: SchG: APG_Upgrade: reset 'disable gong' keys by timer
* 131128 Mayh sp7-scada_v01.10_df_ems00046687_gong_odv_vie
* 121010 Mayh bf-ui_42008_gong_config_47: config comments added
* 120112 Mayh: bof-scada_v01.00_fu_ems562_cuman_vie
* cGong_App,cGong_Dis extende (cMaxMeCl 31)
* 080602 Mayh: feat-SpecUI_CR09_xt_gong: XT gong processing
* 071003 Mayh: bf-ui_38885_gongHeavyLoad_corr01_45:
* cHeavyLoadLimit removed
* 070912 Mayh: bf-ui_38885_gongHeavyLoad_45: heavy load processing
* cHeavyLoadLimit, cHeavyLoadCycle defined
* 070712 oppe : spr-38548 : non periodic gongs have to be lower prior
* 070329 oppe : spr-38070 : Disabled gong status signalized incorrectly
* 070306 kien - bf-globdev_spr37989_remo_mip_45 :
* remove obsolete program mip
* set parameter external_gong to false to prevent
* sbtransmit of program gong to program mip
* $NewRevEnd$
*
*/
/*
Gong output selection ds ul
===================== -
/*
* Decentral gong configuration
*
* XT_DefaultGroup: Default XT Group, all not assigned XTs will
* set to XT_DefaultGroup number.
*
* XT_GroupDef1-20: First Parameter = XTGroup (1-cMaxXTGroup)
* + list of XT numbers (XIDs) which will be
* assigned to group
*
* decentral_gong: For each XT group the gong processing will
* enabled (=true) or disabled (=false)
* This parameter reflect to all assigned XIDs,
* this means XIDs where no gong processing should
* be done (e.g. admistrator XTs, ..) should be
* assigned to a disabled XT-Group.
*
* each_XT: The gong output will be done on each XT (=true)
* of group or only on the first XT (=false),
* fist XT = lowest XT number.
*
* NOTE: each_XT == true:
* The gong processing will be done individually
* for each assigned XID. All activities (enable
* /disable/stop) will impact on each XT
* according permissions (TeAr/MeCl).
*
* each_XT == false: The gong processing will be
* done for the group. The gong output will be
* done on the first XT (=lowest XID number) which
* represents the highest gong of all assigned
* XTs. User actions (enable/disable/stop) will
* will impact on all XTs the group.
*/
XT_DefaultGroup 1
/* XT group 1 2 3 4 5 6 7 8 */
/* Parameters ------------------------------------------------ */
decentral_gong true true true true true true true true
each_XT true true false false false false false false
/* !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!*/
/* ATTENTION : program mip - output via horn on mimic board obsolete !*/
/* see Defect 37989 */
/* !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!*/
/* External gong? -> output via horn on mimic board */
/* SIMATIC number 1 2 3 4 5 6 */
external_gong false false false false false false
fleeter_timeout 3 /* mimic board fleeter timout [s] */
/*
* Element number for all kind of gong messages
* - XT specific: gong message, gong status message
* - Central gong message
* - GongMessageElem == 0 -> means no messages at all
*/
GongMessageElem 10 /* LogOnEl element (0 no messages) */
/*
* Send a GongMessage for for active or all gongs
* false: GongMessage only for active gong will be send
* true : GongMessage for all currently available gongs will be sent
* e.g. currently messages for Gong 1,2,3 are unacknowleged
* - Sound for Gong 3 is triggered
* - GongMessages for 1,2,3 will be sent to mepr
* NOTE: it's implemented only for decentral gong
* NOTE: if there is no GongInfo configured or if either Element or
* infos are not availalbe in NIM, this parameter is irrelevant
*/
MessageForAllGongs false
/*
* Central gong message config parameter
* All currently active central (system) gongs may be sent by a gong
* message.
* TA is specified by:
* - CentralGongMsgB1/B2/B3/GongMessageElem/GongInfo
* GongInfo may be combined (e.g. 1+2->Info 86, 3->Info 87)
*
* Properties:
* - TA need to be valid for messages
* (e.g. CentralGongMsgB1 == 0 or GongMessageElem == 0) no message
* - SendCentralGongMsg need to be 'true'
* - technological permission (TeAr/MeCl) is NOT considered
* even if there is no XT logged in, central messages are triggerd
* - 'Disable' or 'Stop Gong' is NOT considerd
*
*/
CentralGongMsgB1 0 /* SYSTEM 1 */
CentralGongMsgB2 0 /* X-Terms 14 */
CentralGongMsgB3 0 /* X001 1 */
/*
* Non Periodic gongs - general rules / remarks
*
* - all non periodic gongs NEED to be lowest priority, this means
* all non periodic gong numbers need to be lower than the first
* periodic gong (checked at runup with error message).
*
* - non periodic gongs will be sent only once (exactly when it
* happens). Afterwards the event counter will deleted in internal
* administration. This means, if an XT will be connected a non
* periodic gong will not be triggerd again even if the event is still
* not acknowledged (Alternative: periodic gong with greater period).
*
* - NonPeriodicRepeat > 0 [sec]:
* I may happen, that non periodic gongs will be triggered several
* times if many events (leading to a non periodic gong) will be
* received (e.g. GI). For this case it is possible to set a
* NonPeriodicRepeat > 0. This means: The same non periodic gong
* will not be triggerd if it has been triggered within the previous
* (NonPeriodicRepeat) seconds.
*
* Recommendation
* --------------
* Try to avoid non-periodic gongs. For lower priority alarms it is
* a better way to configure a periodic gong with greater period.
* Due to the gong repeat of peroidic gongs, it may not be faild to
* hear by dispatchers.
*/
NonPeriodicRepeat 2