Professional Documents
Culture Documents
Oc Wizard DOC v235 en
Oc Wizard DOC v235 en
Legal information
Use of application examples
Application examples illustrate the solution of automation tasks through an interaction of several components in
the form of text, graphics and/or software modules. The application examples are a free service by Siemens AG
and/or a subsidiary of Siemens AG ("Siemens"). They are non-binding and make no claim to completeness or
functionality regarding configuration and equipment. The application examples merely offer help with typical
tasks; they do not constitute customer-specific solutions. You yourself are responsible for the proper and safe
operation of the products in accordance with applicable regulations and must also check the function of the
respective application example and customize it for your system.
Siemens grants you the non-exclusive, non-sublicensable and non-transferable right to have the application
examples used by technically trained personnel. Any change to the application examples is your responsibility.
Sharing the application examples with third parties or copying the application examples or excerpts thereof is
permitted only in combination with your own products. The application examples are not required to undergo the
customary tests and quality inspections of a chargeable product; they may have functional and performance
defects as well as errors. It is your responsibility to use them in such a manner that any malfunctions that may
occur do not result in property damage or injury to persons.
Disclaimer of liability
Siemens shall not assume any liability, for any legal reason whatsoever, including, without limitation, liability for
the usability, availability, completeness and freedom from defects of the application examples as well as for
related information, configuration and performance data and any damage caused thereby. This shall not apply in
cases of mandatory liability, for example under the German Product Liability Act, or in cases of intent, gross
negligence, or culpable loss of life, bodily injury or damage to health, non-compliance with a guarantee,
fraudulent non-disclosure of a defect, or culpable breach of material contractual obligations. Claims for damages
arising from a breach of material contractual obligations shall however be limited to the foreseeable damage
typical of the type of agreement, unless liability arises from intent or gross negligence or is based on loss of life,
bodily injury or damage to health. The foregoing provisions do not imply any change in the burden of proof to
your detriment. You shall indemnify Siemens against existing or future claims of third parties in this connection
© Siemens AG 2023 All rights reserved
Other information
Siemens reserves the right to make changes to the application examples at any time without notice. In case of
discrepancies between the suggestions in the application examples and other Siemens publications such as
catalogs, the content of the other documentation shall have precedence.
The Siemens terms of use (https://support.industry.siemens.com) shall also apply.
Security information
Siemens provides products and solutions with industrial security functions that support the secure operation of
plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement –
and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and
solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
Such systems, machines and components should only be connected to an enterprise network or the internet if
and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls
and/or network segmentation) are in place.
For additional information on industrial security measures that may be implemented, please visit
https://www.siemens.com/industrialsecurity.
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly
recommends that product updates are applied as soon as they are available and that the latest product versions
are used. Use of product versions that are no longer supported, and failure to apply the latest updates may
increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under
https://www.siemens.com/cert.
Table of contents
Legal information ......................................................................................................................... 2
1 Introduction ........................................................................................................................ 4
1.1 Overview ............................................................................................................... 4
2 Engineering ........................................................................................................................ 5
2.1 Overview ............................................................................................................... 5
2.2 Required Hardware and Software Components ..................................................... 6
3 Function Mechanisms of this Application......................................................................... 7
3.1 Overview ............................................................................................................... 7
3.2 Operation principle of the example program ........................................................... 8
4 Design................................................................................................................................. 9
4.1 Hardware setup ..................................................................................................... 9
5 Installation ........................................................................................................................ 10
5.1 Installation of the Tool.......................................................................................... 10
5.2 Installing the example .......................................................................................... 11
6 Operation of the Application............................................................................................ 12
© Siemens AG 2023 All rights reserved
1 Introduction
1.1 Overview
All new SIMATIC S7-CPUs contain an integrated PROFINET interface which
enables the TCP/IP communication.
The configuration of the TCP/IP communication via this integrated interface is only
possible using the open communication and its function blocks.
The communication blocks FB65 "TCON", FB66 "TDISCON", FB63 "TSEND" and
FB64 "TRCV" are used.
The connection description does not occur via a configuration (in NetPro), therefore
the parameters for each connection must be specified in a data block.
Copyright © Siemens AG 2023 All rights reserved
© Siemens AG 2023 All rights reserved
2 Engineering
2.1 Overview
The Automation solution
Using the “Open Communication Wizard” tool enables simple and clear
specification of the connection parameters.
The tool then exports a UDT or a DB with all parameters of the connection
description into your STEP 7 project.
Using the finished data block, we then give a simple example project of how the
communication is realized in the S7-300 and S7-400 CPU from a program
technology point of view using the above blocks.
This example project shows the configuration and programming of a
communication relationship between a CPU S7-319 and a CPU S7-419 via the
integrated Ethernet interface and the ISO-on-TCP protocol.
Hardware components
Table 2-1
Component No. MLFB / order number Note
PS307 5A 1 6ES7307-1EA00-0AA0
CPU319-3 PN/DP 1 6ES7318-3EL00-0AB0 from V2.5
PS407 10A 1 6ES7407-0KA01-0AA0
CPU416-3 PN/DP 1 6ES7416-3ER05-0AB0 from V5.0
Download connections
Copyright © Siemens AG 2023 All rights reserved
Figure 3-2
FB65_REQ = 1
FB63_REQ = 1
FB66_REQ = 1
Copyright © Siemens AG 2023 All rights reserved
MB20 MB20
© Siemens AG 2023 All rights reserved
SENDDATA RECVDATA
FB66 “TDISCON”
Table 3-1
No. Instruction
1. With a positive edge at FB65_REQ, the FB65 “TCON” tries to establish a
connection using the connection data from the DB10 “TCON_PAR“.
2. After the connection has been established, memory byte 20 is sent to the partner
station with each positive edge at FB63_REQ.
3. The partner receives the data and saves it in memory byte 20.
4. A rising edge at FB66_REQ reactivates the connection.
4 Design
4.1 Hardware setup
The figure below shows the hardware setup of the example. S7-300, S7-400 and
the PG/PC are connected via Industrial Ethernet.
Figure 4-1
192.168.1.31
192.168.1.30
Industrial Ethernet
PG/PC with
STEP 7 and
Open Communication Wizard
5 Installation
5.1 Installation of the Tool
Software Preconditions
STEP 7 V5.7 SP1 or STEP 7 Professional 2021 SR1 can be used with the
following operating systems:
• MS Windows 10 Pro and Enterprise (64-bit)
• MS Windows 11 Pro and Enterprise (64-bit)
• MS Windows Server 2016 (64-bit) (Standard Edition as workstation computer)
• MS Windows Server 2019 (64-bit) (Standard Edition as workstation computer)
• MS Windows Server 2022 (64-bit) (Standard Edition as workstation computer)
STEP 7 Professional has not been tested on any other operating systems; use at
your own risk.
Note that STEP 7 Professional is only released with the MUI versions of the
approved Windows operating systems.
Copyright © Siemens AG 2023 All rights reserved
Compatibility tool
© Siemens AG 2023 All rights reserved
With the compatibility tool, you can put together a compatible selection of software
products or
check existing configurations for compatibility. You can find the compatibility tool at:
https://support.industry.siemens.com/cs/ww/en/view/64847781
Before installation of the new version the old version of the OC-Wizard must be
NOTE
removed via the control panel of your PC.
Note The Open Communication Wizard works with STEP 7 projects. This requires
STEP 7 being installed on this computer. If STEP 7 is not installed the
installation of the Open Communication Wizard will be aborted.
Note The example is runnable immediately. Chapter Operating the example describes
how to control the data transfer
Note In the overview the connection data are shaded in gray, if these data cannot be
changed.
This includes the following:
• Connection data in a UDT. All data blocks in the S7 program which use these UDT
are affected by the changes.
• The connection data in an instance data block. Changing these data may cause time
stamp conflicts.
• Connection data in structures with nesting depth > 1 (e.g.
DB1.TCON.CPU319.TCP.Verb1.block_length…..).
• UDP Connection: Address data is not available, because e.g. in the editor of STEP 7
Copyright © Siemens AG 2023 All rights reserved
The STEP 7 project selected in this dialog as well as the block folder can be
Copyright © Siemens AG 2023 All rights reserved
Note: The “STEP 7 project” dialog mask is only provided when directly calling the OC
Wizard from Windows.
When calling the OC Wizard from the SIMATIC Manager the STEP 7 project
and the block folder is automatically transferred from the SIMATIC Manager. The
project and the block folder from which the OC Wizard was called is valid during
the entire processing time and is only transferred new after exiting the OC
Wizard and calling it again. This is the case for the source station as well as for
the target station.
Therefore, this mask is not offered when calling from the SIMATIC Manager.
In this dialog the uploaded connections in the overview are represented. Here you
Copyright © Siemens AG 2023 All rights reserved
The upload starts automatically. This gives you an overview of the connections of
the selected station. Furthermore, the ID is preassigned with the next free value for
a new connection.
The overview can be exported as *.csv file. To do this click “export”.
The functions “Change” and “Copy” assume the selection of an uploaded
connection in the overview.
When calling the OC Wizard from the SIMATIC Manager the OC Wizard starts with
this dialog. Read back is performed automatically.
Figure 6-4
Copyright © Siemens AG 2023 All rights reserved
Figure 6-5
In this dialog the option “Only communication …” enables you to choose whether
Copyright © Siemens AG 2023 All rights reserved
This option can be changed when creating a new “TCP native” or “ISO on TCP”
connection.
In other cases, this option is defined by the OC Wizard and cannot be changed.
You can also configure these connections individually.
Changing the options causes the values to be reset and the dialog masks to be
represented differently.
Here you enter connection parameters. Please ensure, that the correct interface
Copyright © Siemens AG 2023 All rights reserved
has been selected. Please also note, that rack and slot must be adjusted for S7-
© Siemens AG 2023 All rights reserved
400.
If you do not enter a connection name, a name which is automatically generated by
the tool is used (in the format “auto_name_x”). The connection name is filed in the
comment.
Changing the options causes the values to be reset and the dialog masks to be
represented differently.
In this dialog you enter the port number for the connection.
We recommend using a port number from the range 2000 to 5000.
In the dialog, please specify to which project and to which block folder the
Copyright © Siemens AG 2023 All rights reserved
generated UDT or DB should be imported. The selected STEP 7 project and the
© Siemens AG 2023 All rights reserved
block folder can in this dialog be considered as target station. These details are
preassigned here.
You can accept this default or also specify a different target project or target folder
to which the completed block is compiled and inserted. If you specified a different
target project and after using the “Next” Button a new upload of the specified
project starts automatically.
If a connection is changed (function “Change”), details in this dialog cannot be
changed. The connection data are filed in the same data block and at the same
location.
Assign any block name. When using a symbolic name ensure that the symbolic
name is defined in your S7 program.
The OC Wizard checks whether the specified block already exists in your S7
program. If the block does not yet exist in your S7 program, it will be generated. An
existing data block is analyzed by the OC Wizard and, after a successful analysis,
connection data can be assigned to the data block.
The OC Wizard ignores read protection of data blocks. I.e. data blocks will
NOTICE be overwritten from the OC Wizard. Choose only data blocks without read
protection in OC Wizard.
Note When calling the OC Wizard from the SIMATIC Manager the STEP 7 project
and the block folder is automatically transferred from the SIMATIC Manager. The
project and the block folder from which the OC Wizard was called are shaded in
grey in this mask.
The connection configuration created with the OC Wizard is saved in this block
folder.
Note Up to this dialog mask no changes have yet been made in the STEP 7 project.
Continuing the OC Wizard by pressing the “Next” button causes the compilation
and insertion of the bock into your selected target project.
In this dialog the results of the compilation are displayed. If no errors are displayed
in the report, the changes in the STEP 7 project are made successfully. Otherwise,
no changes are made. If an error message is displayed in the report, you check
whether the used block is not opened otherwise.
Note:
For larger projects, the read-back process can
slow down the display of this dialog a little.
The further process and operation of the OC
Wizard is identical with calling the OC Wizard
from Windows.
Further information on this dialog is available
in chapter “Dialog mask: List of connections”.
Note When calling the OC Wizard from the SIMATIC Manager, the data from the
called block folder is read and transferred in this block folder.
Description OC Wizard
1. Click “Next” in this dialog.
Further information on this dialog is available
in chapter “Dialog mask: Welcome”.
Copyright © Siemens AG 2023 All rights reserved
© Siemens AG 2023 All rights reserved
Description OC Wizard
4. Here you select the types of the new
connection.
Further information on this dialog is available
inchapter “Dialog mask: Choose the type of
your connection”.
Description OC Wizard
7. In this dialog you enter any UDT or DB name.
Further information on this dialog is available
in chapter “Dialog mask: Chose destination
project”.
Description OC Wizard
1. Click “Next” in this dialog.
Further information on this dialog is available
in chapter “Dialog mask: Welcome”.
Description OC Wizard
4. Click “Next” in this dialog.
Further information on this dialog is available
in chapter “Dialog mask: Communication
partner I”.
Description OC Wizard
7. In this dialog you check your details and click
“Next”.
Further information on this dialog is available
in chapter “Dialog mask: Overview”.
Description OC Wizard
1. Click “Next” in this dialog.
Further information on this dialog is available
in chapter “Dialog mask: Welcome”.
Copyright © Siemens AG 2023 All rights reserved
a block folder.
Further information on this dialog is available
in chapter “Dialog mask: STEP 7 project”.
Description OC Wizard
4. Click “Next” in this dialog.
Further information on this dialog is available
in chapter “Dialog mask: Communication
partner I”.
Description OC Wizard
7. In this dialog you check your details and click
“Next”.
Further information on this dialog is available
in chapter “Dialog mask: Overview”.
Note This step is only necessary if connection data are filed in a UDT. Connection
© Siemens AG 2023 All rights reserved
Figure 6-12
Copyright © Siemens AG 2023 All rights reserved
© Siemens AG 2023 All rights reserved
Table 6-1
No. Instruction
9. Triggering the connection setup with rising edge at FB65_REQ in both
communication partners.
10. As soon as the connection has been established (FB65_connected) you trigger
the data transfer in the CPU319 with a rising edge at FB63_REQ.
11. Data is continuously received in the S7-400. Evaluate the rising edge of
FB64_NDR to process the received data.
12. After sending was completed, the connection can be cancelled with a rising edge
at FB66_REQ. This step must be performed in both communication partners.
7 Appendix
7.1 Service and support
Industry Online Support
Do you have any questions or need assistance?
Siemens Industry Online Support offers round the clock access to our entire service and support
know-how and portfolio.
The Industry Online Support is the central address for information about our products, solutions
and services.
Product information, manuals, downloads, FAQs, application examples and videos – all
information is accessible with just a few mouse clicks:
support.industry.siemens.com
Technical Support
The Technical Support of Siemens Industry provides you fast and competent support regarding
all technical queries with numerous tailor-made offers
– ranging from basic support to individual support contracts. Please send queries to Technical
Support via Web form:
siemens.com/SupportRequest
© Siemens AG 2023 All rights reserved
Service offer
Our range of services includes the following:
• Plant data services
• Spare parts services
• Repair services
• On-site and maintenance services
• Retrofitting and modernization services
• Service programs and contracts
You can find detailed information on our range of services in the service catalog web page:
support.industry.siemens.com/cs/sc
The Siemens Industry Mall is the platform on which the entire siemens Industry product portfolio
is accessible. From the selection of products to the order and the delivery tracking, the Industry
Mall enables the complete purchasing processing – directly and independently of time and
location:
mall.industry.siemens.com
Frauenauracher Str. 80
91056 Erlangen, Germany
mailto: tech.team.motioncontrol@siemens.com
\3\ “System software for S7-300/400 system- and standard functions” manual
http://support.automation.siemens.com/WW/view/en/1214574