Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

M.T.B.

F TEST
Go to cover page
Zhejiang Dahua Vision Technology Co.,Ltd DOC. No Report Version
A
Model Brand Stage Date Test by Approved by
DHI-LM43-S400 / / 2018/1/11~2018/5/10 / /
F/W Quantity Bug description Conclusion
10 PASS
1.Test Purpose
The purpose of the test is to collect information about Monitor failure case at the early period by elevated thermal test and
offer the reliability information about storage, B/I etc. as a reference to the improvement of design
2.Test Equipment:
1. B/I Room
3.Test Condition
1. TEMP.: 40 ℃
2. CONFIDENCE LEVEL : 90%
3. VOLTAGE : 220Vac
4. MTBF Calculation Formular

MTBF= ∗ ∗ ∗ / .
Note:TL: Total Life Test Time N: Numbers Of Test Sets
Tr: Room Temperature.(40°C) Ta: Environment Temperature (25°C)
C.LÒ= Confidence Level(90%) Ft: Hours Before Defect Occurred
BOE K-tronics condition--> FCC = 2 ^((Ta-Tr) / 10 )= 2^((40-25)/10 )= 2^1.5 = 2.8284

4.Test Criteria
Calculate MTBF N*TL
Target 30000 24423

FAILURE NUMER
C.L
0 1 2 3 4 5 6 7

90% 2.3026 3.8897 5.3223 6.6808 7.9936 9.2742 10.5321 11.7709


85% 1.8971 3.3724 4.7231 6.0135 7.2670 8.4947 9.7031 10.8965
80% 1.6094 2.9943 4.2790 5.5151 6.7210 7.9060 9.0754 10.2325
75% 1.3863 2.6926 3.9204 5.0194 6.2744 7.4227 8.5585 9.6844
5.Test Data
ITEM N*TL Ft Ta Tr CL(R)

Target 24423 0 40℃ 25℃ 2.3026

Plan Period Day Qty.(N) Tested(TL) Sum of(N*TL) Defect MTBF Remark

PVT 2018/1/11 2018/5/10 120 10 2880 28800 0 35376

Total test - - - 28800 0 35376

Special notice:

6.Remark

You might also like