Professional Documents
Culture Documents
El Sarmiento8823
El Sarmiento8823
A A
WH REF
B 5
RH R
B
8 6 DRYING AREA
pb
TV
7 R RH REF
pb R RH
WP
pb
5 10
6 4 1
2 5 9
4 11
1
WP
3 2 6 REF
ACU
ACU R RH REF
pb
C 7 C
3
6 5 4 1
WH
3 2 WH
TV WH
ACU TV
8
ACU TV
WH
TV
3 2
3
6 5 4 1 4
TV
D D
R RH REF pb ACU
ACU
pb UP
WP
WP
WP WP WP
1 C O R R I D O R
2
E ACU
2 3 ACU ACU
E
RH
RH
RH
RH
4
R
WH WH WH WH
3 3 3
R
3
6
6 6 6
5 5 5
5
REF REF
REF
4 4
REF
pb
pb
pb
pb
4 1
1 1
1 1
F WP F
2 2 2 2
TV TV TV TV
G G
H H
I I
CERTIFIED BY: PRC REG. NO.: 0004633 REPUBLIC ACT 9266 SECTION 33 PROJECT TITLE: PROPOSED THREE STOREY SHEET CONTENTS: REVISION NOTES: SHEET DETAIL:
DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DULY
SIGNED, STAMPED OR SEALED AS INSTRUMENTS OF SERVICE, ARE THE RESIDENCE NO. DESCRIPTION DATE CONTENT
TIN NO.: 280-583-368 PROPERTIES AND DOCUMENTS OF THE ARCHITECT/ENGINEER/DESIGNER
1 N/A N/A
AS SHOWN
EL-01
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT LOCATION: SAN ANDRES ST. ANGELES, PAMPANGA
J SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF J
DANVIR V. MICLAT PTR NO.: 9516815C SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS 2
OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE
ELECTRICAL ENGINEER DATE ISSUED: 01-03-2023
WRITTEN CONSENT OF ARCHITECT/ENGINEER/DESIGNER OR AUTHOR OF SAID
DRAFT BY: CHECKED BY:
3 SHEET NO. TOTAL SHEET
DOCUMENTS.
PROJECT OWNER: MR. & MRS. AUGUSTO SARMIENTO 4
PLACE ISSUED: PAMPANGA ADDRESS: ANGELES CITY, PAMPANGA DATE: DATE: 5 12 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A A
S-l
S-g(3)
OTHERWISE INDICATED THE MINIMUN SIZE FOR POWER AND LIGHTING SHALL BE 3.5 mm2 WIRE
S-i(2) s
i2 i2
g1 s
S-n(2) AS MANUFACTURED BY PHELPS DODGE SHALL BE USED.
r2 r2
l l
i2
i1
g3
n1 n1 n1 4. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE
g3 g3
C S-i(3)
FOR CONNECTION TO THE POWER SUPPLY. C
j3
i3 d2
d2
S-r(3) 5. ALL RECEPTACLES SHALL BE OF THE GROUNDING TYPE.
S-k r1
q2 q1
k k i2 i2 e
7 6. ALL SWITCHES SHALL BE PROVIDED WITH NEUTRAL WIRE.
j3
S-e
d2
S-d(3)
11 S-q(2)
S-f(2)
d1
S-p(2)
s
7. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANELBOARDS, LIGHTING FIXTURES AND ALL
f2
f1
l p2 p1
NON-CURRENT CARRYING METAL PARTS BE PROPERLY GROUNDED IN ACCORDANCE WITH THE
m3 m3 m3
k
k
d3
d3
d3
PHILIPPINE ELECTRICAL CODE.
a3
a3 a3
S-o(2)
8. ALL PANELBOARDS SHALL BE PROVIDED WITH GROUNDING BUS. CIRCUIT BREAKERS SHALL BE
BOLT-ON TYPE AND OF THE THERMAL-MAGNETIC TYPE, COMMON TRIP WITH THE RATINGS AND
c2 c1
7
o2 o1
S-c(2)
m2 NUMBER OF POLES AS INDICATED IN THE DRAWINGS.
i1 i1 i1
D S-b
a1
9. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS: D
S-a(3)
b
a2
A) LIGHT SWITCHES . . . . . . . . . 1.4M ABOVE FLOOR FINISH.
i1 i1 i1
a2
a2
l
o2 o1
m1 m1
S-l
S-m(3)
m1
l
B) CONVENIENCE OUTLETS . . . . . . 0.3M ABOVE FLOOR FINISH OR AS REQUIRED.
C) TELEPHONE OUTLETS . . . . . . . 0.3M ABOVE FLOOR FINISH OR AS REQUIRED.
3 sx-g
S-z
3 sx-g
S-k
D) PANELBOARDS & CABINETS . . . . 1.4M ABOVE FLOOR FINISH AT CENTER OR AS
l
S-f g
REQUIRED.
S-h
3 sx-g
g
h
g
z
10. ALL MOUNTING HEIGHTS SHALL BE SUBJECT TO ARCHITECTS APPROVAL PRIOR TO
f
INSTALLATION.
k
k 11. WHENEVER NECESSARY PULL BOXES SHALL BE PROVIDED EVEN IF NOT INDICATED IN THE
o1 r1 u1 x1
l l l
PLANS.
E S-b S-d S-f 12. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION E
b
a2 c2 d f
e2 OF A DULY QUALIFIED LICENSED ELECTRICAL ENGINEER.
S-o(2)
p2 s2
S-r(2) S-u(2) v2 y2
S-x(2)
13. PROVIDE LIGHTNING ELECTRODE AND ARRESTER TO GROUND.
S-a(2) S-c(2) S-e(2) o2 S-o(2) S-s(2)
s1
r2
u2 S-v(2) S-y(2)
x2 14. ALL CABLES (LAN,WAN & CATV) SHALL BE CONNECTED TO CENTRAL HUB (RJ45).
p1 v1 y1
a2 a2 c2 c2 e2 e2
15. HDMI CABLE SHALL BE CONNECTED FROM CENTRAL HUB TO CCTV MONITOR.
16. DOORBELL SHALL BE CONNECTED TO DOORBELL MONITOR.
a2 a2 c2 c2 e2 e2
q1 t1 w1 w1
n1 n1 q1 t1
CATV CABLE TV
WAN WAN OUTLET
USB O
3 GANG OUTLET W/ USB OUTLET
H RJ45 CENTRAL HUB H
ELECTRICAL LIGHTING LAYOUT ELECTRICAL LIGHTING LAYOUT ELECTRICAL LIGHTING LAYOUT CCTV CCTV
I I
CERTIFIED BY: PRC REG. NO.: 0004633 REPUBLIC ACT 9266 SECTION 33 PROJECT TITLE: PROPOSED THREE STOREY SHEET CONTENTS: REVISION NOTES: SHEET DETAIL:
DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DULY
SIGNED, STAMPED OR SEALED AS INSTRUMENTS OF SERVICE, ARE THE RESIDENCE NO. DESCRIPTION DATE CONTENT
TIN NO.: 280-583-368 PROPERTIES AND DOCUMENTS OF THE ARCHITECT/ENGINEER/DESIGNER
1 N/A N/A
AS SHOWN
EL-02
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT LOCATION: SAN ANDRES ST. ANGELES, PAMPANGA
J SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF J
DANVIR V. MICLAT PTR NO.: 9516815C SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS 2
OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE
ELECTRICAL ENGINEER DATE ISSUED: 01-03-2023
WRITTEN CONSENT OF ARCHITECT/ENGINEER/DESIGNER OR AUTHOR OF SAID
DRAFT BY: CHECKED BY:
3 SHEET NO. TOTAL SHEET
DOCUMENTS.
PROJECT OWNER: MR. & MRS. AUGUSTO SARMIENTO 4
PLACE ISSUED: PAMPANGA ADDRESS: ANGELES CITY, PAMPANGA DATE: DATE: 5 13 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14