1 2 3 4 5 6 7 8 9 10 11 12 13 14

A A

WH REF

B 5
RH R
B
8 6 DRYING AREA

pb
TV
7 R RH REF
pb R RH
WP

pb
5 10
6 4 1
2 5 9
4 11
1
WP
3 2 6 REF

ACU WH ACU ACU


ACU
TV
TV

ACU
ACU R RH REF
pb
C 7 C
3
6 5 4 1
WH

3 2 WH

TV WH
ACU TV
8

ACU TV
WH
TV

3 2
3
6 5 4 1 4
TV

D D
R RH REF pb ACU
ACU

pb UP

WP
WP
WP WP WP

1 C O R R I D O R
2

E ACU

2 3 ACU ACU
E

RH

RH

RH

RH
4

R
WH WH WH WH

3 3 3

R
3
6
6 6 6
5 5 5
5
REF REF
REF

4 4
REF

pb

pb
pb

pb
4 1
1 1
1 1
F WP F
2 2 2 2
TV TV TV TV

ACU ACU ACU ACU

G G

H H

ELECTRICAL POWER LAYOUT ELECTRICAL POWER LAYOUT ELECTRICAL POWER LAYOUT


1 GROUND FLOOR 2 SECOND FLOOR 3 THIRD FLOOR
EL-01 SCALE 1:100 EL-01 SCALE 1:100 EL-01 SCALE 1:100

I I

CERTIFIED BY: PRC REG. NO.: 0004633 REPUBLIC ACT 9266 SECTION 33 PROJECT TITLE: PROPOSED THREE STOREY SHEET CONTENTS: REVISION NOTES: SHEET DETAIL:
DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DULY
SIGNED, STAMPED OR SEALED AS INSTRUMENTS OF SERVICE, ARE THE RESIDENCE NO. DESCRIPTION DATE CONTENT
TIN NO.: 280-583-368 PROPERTIES AND DOCUMENTS OF THE ARCHITECT/ENGINEER/DESIGNER
1 N/A N/A
AS SHOWN
EL-01
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT LOCATION: SAN ANDRES ST. ANGELES, PAMPANGA
J SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF J
DANVIR V. MICLAT PTR NO.: 9516815C SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS 2
OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE
ELECTRICAL ENGINEER DATE ISSUED: 01-03-2023
WRITTEN CONSENT OF ARCHITECT/ENGINEER/DESIGNER OR AUTHOR OF SAID
DRAFT BY: CHECKED BY:
3 SHEET NO. TOTAL SHEET
DOCUMENTS.
PROJECT OWNER: MR. & MRS. AUGUSTO SARMIENTO 4
PLACE ISSUED: PAMPANGA ADDRESS: ANGELES CITY, PAMPANGA DATE: DATE: 5 12 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14

A A

GENERAL ELECTRICAL NOTES:


1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THESE
PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE
PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATIONS OF THE LOCAL ENFORCING
AUTHORITY, AND THE REQUIREMENTS OF THE LOCAL POWER AND TELEPHONE COMPANIES. THE
ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED
B B
ELECTRICAL ENGINEER.
2. SERVICE FROM THE ELECTRIC POWER COMPANY SHALL BE 230V, 1Ø 60 HZ.
s s s s
ALL INSTALLATIONS SHALL BE CONCEALED FROM VIEW BY INSTALLING CONDUCTORS IN PVC
9 S-m(2)
j j j
m2
m1 j2
S-j
12
CONDUIT. POWER AND LIGHTING DISTRIBUTION EMBEDDED IN CONCRETE SHALL BE IN PVC
S-j(3)
j3 r3 r3 CONDUITS. EXPOSED POWER AND LIGHTING DISTRIBUTION SHALL BE IN PVC CONDUITS, BY
S-s(3)
g2 g2 MEANS OF HANGERS
l l
j1 j1
h n2 3. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THHN" UNLESS
7
g2 n2
S-h

S-l
S-g(3)
OTHERWISE INDICATED THE MINIMUN SIZE FOR POWER AND LIGHTING SHALL BE 3.5 mm2 WIRE
S-i(2) s
i2 i2
g1 s
S-n(2) AS MANUFACTURED BY PHELPS DODGE SHALL BE USED.
r2 r2

l l
i2
i1

g3
n1 n1 n1 4. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE
g3 g3
C S-i(3)
FOR CONNECTION TO THE POWER SUPPLY. C
j3
i3 d2
d2
S-r(3) 5. ALL RECEPTACLES SHALL BE OF THE GROUNDING TYPE.
S-k r1

q2 q1
k k i2 i2 e
7 6. ALL SWITCHES SHALL BE PROVIDED WITH NEUTRAL WIRE.
j3
S-e
d2
S-d(3)
11 S-q(2)

S-f(2)
d1
S-p(2)
s
7. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANELBOARDS, LIGHTING FIXTURES AND ALL
f2
f1
l p2 p1
NON-CURRENT CARRYING METAL PARTS BE PROPERLY GROUNDED IN ACCORDANCE WITH THE
m3 m3 m3
k
k
d3
d3
d3
PHILIPPINE ELECTRICAL CODE.
a3
a3 a3
S-o(2)
8. ALL PANELBOARDS SHALL BE PROVIDED WITH GROUNDING BUS. CIRCUIT BREAKERS SHALL BE
BOLT-ON TYPE AND OF THE THERMAL-MAGNETIC TYPE, COMMON TRIP WITH THE RATINGS AND
c2 c1
7
o2 o1

S-c(2)
m2 NUMBER OF POLES AS INDICATED IN THE DRAWINGS.
i1 i1 i1
D S-b
a1
9. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS: D
S-a(3)
b
a2
A) LIGHT SWITCHES . . . . . . . . . 1.4M ABOVE FLOOR FINISH.
i1 i1 i1
a2
a2
l
o2 o1
m1 m1
S-l
S-m(3)
m1
l
B) CONVENIENCE OUTLETS . . . . . . 0.3M ABOVE FLOOR FINISH OR AS REQUIRED.
C) TELEPHONE OUTLETS . . . . . . . 0.3M ABOVE FLOOR FINISH OR AS REQUIRED.
3 sx-g
S-z
3 sx-g
S-k
D) PANELBOARDS & CABINETS . . . . 1.4M ABOVE FLOOR FINISH AT CENTER OR AS
l

S-f g
REQUIRED.
S-h
3 sx-g
g
h

g
z
10. ALL MOUNTING HEIGHTS SHALL BE SUBJECT TO ARCHITECTS APPROVAL PRIOR TO
f
INSTALLATION.
k
k 11. WHENEVER NECESSARY PULL BOXES SHALL BE PROVIDED EVEN IF NOT INDICATED IN THE
o1 r1 u1 x1
l l l
PLANS.
E S-b S-d S-f 12. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION E
b
a2 c2 d f
e2 OF A DULY QUALIFIED LICENSED ELECTRICAL ENGINEER.
S-o(2)
p2 s2
S-r(2) S-u(2) v2 y2
S-x(2)
13. PROVIDE LIGHTNING ELECTRODE AND ARRESTER TO GROUND.
S-a(2) S-c(2) S-e(2) o2 S-o(2) S-s(2)

s1
r2
u2 S-v(2) S-y(2)
x2 14. ALL CABLES (LAN,WAN & CATV) SHALL BE CONNECTED TO CENTRAL HUB (RJ45).
p1 v1 y1
a2 a2 c2 c2 e2 e2

15. HDMI CABLE SHALL BE CONNECTED FROM CENTRAL HUB TO CCTV MONITOR.
16. DOORBELL SHALL BE CONNECTED TO DOORBELL MONITOR.
a2 a2 c2 c2 e2 e2
q1 t1 w1 w1
n1 n1 q1 t1

S-n(2) S-q(2) S-t(2)


ELECTRICAL LEGEND:
S-w(2)
pb
F PANELBOARD F
a2 n2 n2 q2 q2 t2 w2 w2
a2 c2 c2 e2 e2
t2

S-1 ONE GANG SWITCH COVE LIGHT


7 7
7 7
5 S-2 TWO GANG SWITCH SPOTLIGHT
a1 a1 c1 c1 e1 e1
n2 q2 q2 t2 t2 w2 w2
n2
S-3 THREE GANG SWITCH
CENTER LIGHT
3 Sx THREE WAY, ONE GANG SWITCH
DUPLEX CONVENIENCE OUTLET
1 CIRCUIT HOMERUN
FIRE ALARM BELL
1x36W LED W/ LUMINAIRES FA
G G
9W CIRCULAR LED PANEL LIGHT (15mm dia) ACU OUTLET
ACU

LED EMERGENCY LIGHT FM


FLOOR MOUNTED OUTLET
FIRE ALARM BELL
EXHAUST FAN FAB

LAN C LAN CEILING MOUNTED OUTLET DOOR BELL PUSH


DOOR BELL CHIME
LAN LAN OUTLET DBC

CATV CABLE TV
WAN WAN OUTLET
USB O
3 GANG OUTLET W/ USB OUTLET
H RJ45 CENTRAL HUB H
ELECTRICAL LIGHTING LAYOUT ELECTRICAL LIGHTING LAYOUT ELECTRICAL LIGHTING LAYOUT CCTV CCTV

1 GROUND FLOOR 2 SECOND FLOOR 3 THIRD FLOOR


SCALE 1:100 EL-02 SCALE 1:100 EL-02 SCALE 1:100
EL-02

I I

CERTIFIED BY: PRC REG. NO.: 0004633 REPUBLIC ACT 9266 SECTION 33 PROJECT TITLE: PROPOSED THREE STOREY SHEET CONTENTS: REVISION NOTES: SHEET DETAIL:
DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DULY
SIGNED, STAMPED OR SEALED AS INSTRUMENTS OF SERVICE, ARE THE RESIDENCE NO. DESCRIPTION DATE CONTENT
TIN NO.: 280-583-368 PROPERTIES AND DOCUMENTS OF THE ARCHITECT/ENGINEER/DESIGNER
1 N/A N/A
AS SHOWN
EL-02
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT LOCATION: SAN ANDRES ST. ANGELES, PAMPANGA
J SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF J
DANVIR V. MICLAT PTR NO.: 9516815C SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS 2
OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE
ELECTRICAL ENGINEER DATE ISSUED: 01-03-2023
WRITTEN CONSENT OF ARCHITECT/ENGINEER/DESIGNER OR AUTHOR OF SAID
DRAFT BY: CHECKED BY:
3 SHEET NO. TOTAL SHEET
DOCUMENTS.
PROJECT OWNER: MR. & MRS. AUGUSTO SARMIENTO 4
PLACE ISSUED: PAMPANGA ADDRESS: ANGELES CITY, PAMPANGA DATE: DATE: 5 13 18