1 2 3 4 5 6 7 8 9 10 11 12 13 14

A A

A B C D E' E F
A B C D E' E F

11615
B B
11615 1500 1550 1675 1000 2980 2910
1500 1550 1675 1000 2980 2910

10MM Ø TEMP. BARS SPACED


2B-1
@400MM BOTHWAYS 1
1

1650

1650
2B-1

2B-1
TB-1 TB-1 S-1

1650

1650
TB-1

TB-1
2B-1 2B-1
C1-F3 C1-F2 C1-F2
2
2
TB-1 TB-1 TB-1
C C

2900

2900
C1-F1

2B-1
2B-1

2B-1
C1-F1

TB-1
S-1

TB-1
2900

2900
S-1

TB-1
TB-1
2B-1 2B-1
3
3 TB-1
TB-1
C1-F1 C1-F1

2935

2935
C1-F1

-1

2B-1
2B-1
2B-1
TB
2935

2935
S-1 S-1

TB-1

TB-1
TB-1

D 2B-1 2B-1 D
4 PC
4
TB-1
C1-F1 C1-F1

2965

2965
2B-1

2B-1
2B-1
S-1 S-1
2965

2965
TB-1
TB-1

2B-1

21150

21150
2B-1
21150

21150
5
5 TB-1 TB-1

2200

2200
2B-1
2B-1

2B-1
S-1
2200

2200
C1-F1 C1-F1
TB-1

TB-1
E E
TB-1 2B-1 2B-1 2B-1 2B-1
6
6
TB-1 TB-1 TB-1 TB-1
C1-F1
C1-F2 C1-F1 C1-F1
C1-F2

2B-1

2B-1
S-1 S-1 S-1 S-1

2B-1

2B-1
5850

5850
5850

5850
2B-1 2B-1 2B-1 2B-1

2B-1
TB-1
TB-1

TB-1

TB-1
TB-1

F F

S-1 S-1 S-1 S-1

7 2B-1 2B-1 2B-1 2B-1


7
TB-1 TB-1 TB-1 TB-1

2650

2650
2B-1

2B-1
2B-1

2B-1
TB-1

2B-1
TB-1
TB-1

TB-1

C1-F2 C1-F1 C1-F1 C1-F1 S-1 S-1 S-1 S-1


2650

2650
C1-F2
TB-1

TB-1 TB-1 TB-1 2B-1 2B-1 2B-1 2B-1


G 8 PC PC PC
G
8
C1-F2

H H
1500 1550 1675 1000 2980 2910 1515
1500 1550 1675 1000 2980 2910 1515 13125
13125

1 FOUNDATION PLAN 2 SECOND FLOOR FRAMING PLAN


SCALE 1:100 ST-01 SCALE 1:100
ST-01

I I

CERTIFIED BY: PRC REG. NO.: 0155062 REPUBLIC ACT 9266 SECTION 33 PROJECT TITLE: PROPOSED THREE STOREY SHEET CONTENTS: REVISION NOTES: SHEET DETAIL:
DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DULY
SIGNED, STAMPED OR SEALED AS INSTRUMENTS OF SERVICE, ARE THE RESIDENCE NO. DESCRIPTION DATE CONTENT
TIN NO.: 342-848-717 PROPERTIES AND DOCUMENTS OF THE ARCHITECT/ENGINEER/DESIGNER
1 N/A N/A
AS SHOWN
ST-01
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT LOCATION: SAN ANDRES ST. ANGELES, PAMPANGA
J
JULIUS G. ORDOÑEZ PTR NO.: 9516889
SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS 2
J
OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE
CIVIL ENGINEER DATE ISSUED: 01-03-2023 WRITTEN CONSENT OF ARCHITECT/ENGINEER/DESIGNER OR AUTHOR OF SAID
DRAFT BY: CHECKED BY:
3 SHEET NO. TOTAL SHEET
DOCUMENTS.
PROJECT OWNER: MR. & MRS. AUGUSTO SARMIENTO 4
PLACE ISSUED: PAMPANGA ADDRESS: ANGELES CITY, PAMPANGA DATE: DATE: 5
08 13
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14

A A

A B C D E' E F
A B C D E' E F

B 11615 B
11615 1500 1550 1675 1000 2980 2910
1500 1550 1675 1000 2980 2910

RB-1 RB-1
3B-1 3B-1
1
1

1650

1650
RB-1
RB-1
1650

1650
3B-1
3B-1
3B-1
S-1 S-1 RB-1
RB-1
3B-1 3B-1 2
2

RB-1
C C

2900

2900
RB-1
RB-1
2900

2900
3B-1

3B-1
3B-1
S-1 S-1

PC RB-1 RB-1
3B-1 3B-1 3
3

RB-1
2935

2935
RB-1

RB-1
3B-1
2935

2935
3B-1
3B-1
S-1 S-1

D RB-1 RB-1 D
3B-1
PC
3B-1 4
4

2965

2965
RB-1
RB-1

RB-1
2965

2965
3B-1
3B-1

S-1 S-1

3B-1

21150
RB-1

21150
RB-1
21150

21150
3B-1 3B-1
5
5

2200

2200
RB-1

RB-1
2200

2200
3B-1

3B-1

E S-1 E
RB-1
3B-1 3B-1 3B-1 6
6

S-1 S-1 S-1 S-1

5850

5850
5850

5850
3B-1
3B-1

3B-1
3B-1
3B-1

F 3B-1 3B-1 3B-1 3B-1 F

S-1 S-1 S-1 S-1


7
7 3B-1 3B-1 3B-1 3B-1

PC

2650

2650
2650

2650
3B-1

3B-1
3B-1
3B-1

3B-1

S-1 S-1 S-1 S-1

G G
3B-1 3B-1 3B-1 3B-1 8
8

H H
1500 1550 1675 1000 2980 2910 1515
1500 1550 1675 1000 2980 2910 1515
13125
13125

1 THIRD FLOOR FRAMING PLAN 2 ROOF BEAM FRAMING PLAN


ST-02 SCALE 1:100 ST-02 SCALE 1:100

I I

CERTIFIED BY: PRC REG. NO.: 0155062 REPUBLIC ACT 9266 SECTION 33 PROJECT TITLE: PROPOSED THREE STOREY SHEET CONTENTS: REVISION NOTES: SHEET DETAIL:
DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DULY
SIGNED, STAMPED OR SEALED AS INSTRUMENTS OF SERVICE, ARE THE RESIDENCE NO. DESCRIPTION DATE CONTENT
TIN NO.: 342-848-717 PROPERTIES AND DOCUMENTS OF THE ARCHITECT/ENGINEER/DESIGNER
1 N/A N/A
AS SHOWN
ST-02
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT LOCATION: SAN ANDRES ST. ANGELES, PAMPANGA
J
JULIUS G. ORDOÑEZ PTR NO.: 9516889
SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS 2
J
OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE
CIVIL ENGINEER DATE ISSUED: 01-03-2023 WRITTEN CONSENT OF ARCHITECT/ENGINEER/DESIGNER OR AUTHOR OF SAID
DRAFT BY: CHECKED BY:
3 SHEET NO. TOTAL SHEET
DOCUMENTS.
PROJECT OWNER: MR. & MRS. AUGUSTO SARMIENTO 4
PLACE ISSUED: PAMPANGA ADDRESS: ANGELES CITY, PAMPANGA DATE: DATE: 5
09 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14

A A

50MMx150MMx2.0MM TUBULAR STEEL FOR RAFTERS


50MMx75MMx1.2MM C-PURLINS SPACED @ 600MM
SCHEDULE OF SLAB
REINFORCING STEEL BARS
1345

B
MARK THICKNESS (mm) B
1200

50MMx100MMx1.5MM TUBULAR STEEL FOR RAFTERS


50MMx75MMx1.2MM C-PURLINS SPACED @ 600MM
8900
ALONG SHORT DIRECTION ALONG LONG DIRECTION
1200

600 600 600 600 600 600 600 600 600 600 600 600 600 600
VARIES
S1 125 12mm Ø 200mm 12mm Ø 200mm
1200
1200 1200

C C
13345

8900
400
1200

3-10MM dia. CONT BARS WITH


10MM dia. CLEATS SPACED
AT 400MM O.C
1200
1200

A125MM THK. CHB WITH 10MM dia.


VERTICAL BARS SPACED AT 800MM O.C
D AND 12MM dia. HORIZONTAL BARS ON
EVERY 3RD LAYOUT OF CHB. D
1200
1200

NGL

125MM THK. CHB WITH 10MM


dia. VERTICAL BARS SPACED
AT 800MM O.C

400
VARIES 3-10MM dia. HORIZONTAL BARS WITH 12MM dia. HORIZONTAL BARS
ON EVERY THIRD LAYER OF CHB
10MM TRANSVERSE SPACED
600 600 600 600 600 600 600 600 600 600 600 600 600 600 AT 400MM O.C
EVERY 3RD LAYOUT OF CHB.

8900 MM
3 TYPICAL SLAB DETAILS
E SCALE NTS E

200
ST-03
1 ROOF FRAMING PLAN 2 TYPICAL RAFTER DETAILS 400

ST-03 SCALE NTS ST-03 SCALE NTS


SECTION PLAN

1500 1500 1500


625.05 250 624.95 1250 250 1250 250

F fc = 3,000 psi F
SCHEDULE OF BEAMS

527.17

450
fy = 40,000 psi

525
FOR COLUMN FOOTING USE: FOR COLUMN FOOTING USE: FOR COLUMN FOOTING USE:
1500x1500x300MM 1500x1500x300MM 1500x1500x300MM
WITH 10-16MM dia. WITH 10-16MM dia. WITH 10-16MM dia.
REBARS BOTHWAYS REBARS BOTHWAYS REBARS BOTHWAYS

STEEL REINFORCEMENT

1500

1500

1500
450
450

1050
MARK SIZE BAR SIZE LEFT SUPPORT MID-SUPPORT RIGHT SUPPORT FOR COLUMN-1 USE: FOR COLUMN-1 USE: FOR COLUMN-1 USE:

SPACING OF STIRRUPS 250x450MM 4pcs-20MM dia.& 4pcs 16MM dia., 250x450MM 4pcs-20MM dia.& 4pcs 16MM dia., 250x450MM 4pcs-20MM dia.& 4pcs 16MM dia.,

522.83
WITH 10MM dia. LATERAL TIES WITH 10MM dia. LATERAL TIES WITH 10MM dia. LATERAL TIES

525
SPACED @3-50mm, @3-100mm, SPACED @3-50mm, @3-100mm, SPACED @3-50mm, @3-100mm,
B H TOP BOTTOM TOP BOTTOM TOP BOTTOM @5-150mm, REST @200MM @5-150mm, REST @200MM @5-150mm, REST @200MM

(10mm dia) PLAN


C1F1 PLAN
C1F2 PLAN
C1F2
mm mm mm mm mm mm mm mm mm
200
GROUND FLOOR FOR GRADE TIE BEAM
200x400MM 6pcs-12MM dia.
WITH 10MM dia. STIRRUPS
FOR COLUMN USE:
250x450MM 4pcs-20MM dia.& 4pcs 16MM dia.,
RSB REINFORCEMENTS
SPACED @4-50mm, @4-100mm,

400
with 10MM dia. TIES SPACED @3-50mm, @3-100mm, FOR GRADE TIE BEAM FOR GRADE TIE BEAM
G 4-150mm, REST @ 200MM M.O.C. @5-150mm, REST @200MM 200x400MM 6pcs-16MM dia.
WITH 10MM dia. STIRRUPS
FOR COLUMN USE:
250x450MM 4pcs-20MM dia.& 4pcs 16MM dia.,
WITH 10MM dia. LATERAL TIES
200x400MM 6pcs-16MM dia.
WITH 10MM dia. STIRRUPS
FOR COLUMN USE:
250x450MM 4pcs-20MM dia.& 4pcs 16MM dia.,
WITH 10MM dia. LATERAL TIES
G
TB-1 200 400 Ø16mm 4 3 3 3 3 3 4@ 50, 4@ 100, 4 @ 150, REST @ 200MM M.O.C SPACED @1-50mm, @3-100mm,
3-150mm, REST @ 200MM
SPACED @3-50mm, @3-100mm,
5-150mm, REST @ 200MM
SPACED @1-50mm, @3-100mm,
3-150mm, REST @ 200MM
SPACED @3-50mm, @3-100mm,
5-150mm, REST @ 200MM
FINISHED FLOOR LINE FINISHED FLOOR LINE FINISHED FLOOR LINE

200

600

600

600
SECOND FLOOR

400
NATURAL GROUND LINE NATURAL GROUND LINE NATURAL GROUND LINE

2B-1 200 400 Ø16mm 5 3 3 5 5 3 1@ 50, 3@ 100, 3 @ 150, REST @ 200MM M.O.C
200

1100

1100

1100
3B-1 200 400 Ø16mm 5 3 3 5 5 3 1@ 50, 3@ 100, 3 @ 150, REST @ 200MM M.O.C

1400

1400

1400
FOR COLUMN FOOTING USE: FOR COLUMN FOOTING USE: FOR COLUMN FOOTING USE:
1500x1500x300MM ISOLATED FOOTING 1500x1500x300MM ISOLATED FOOTING 1500x1500x300MM ISOLATED FOOTING

400
WITH 10pcs-16MM dia. RSB WITH 10pcs-16MM dia. RSB WITH 10pcs-16MM dia. RSB
BOTH WAYS WITH HOOK BOTH WAYS WITH HOOK BOTH WAYS WITH HOOK

H H

300

300

300
150 50mm THK. GRAVEL BED 50mm THK. GRAVEL BED 50mm THK. GRAVEL BED

ROOF FRAMING SECTION SECTION SECTION


400

RB-1 150 400 Ø16mm 4 2 2 4 4 2 1@ 50, 3@ 100, 3 @ 150, REST @ 200MM M.O.C

I
4 COLUMN FOOTING DETAILS I

ST-03 SCALE NTS

CERTIFIED BY: PRC REG. NO.: 0155062 REPUBLIC ACT 9266 SECTION 33 PROJECT TITLE: PROPOSED THREE STOREY SHEET CONTENTS: REVISION NOTES: SHEET DETAIL:
DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DULY

TIN NO.: 342-848-717


SIGNED, STAMPED OR SEALED AS INSTRUMENTS OF SERVICE, ARE THE
PROPERTIES AND DOCUMENTS OF THE ARCHITECT/ENGINEER/DESIGNER
RESIDENCE NO. DESCRIPTION DATE CONTENT

1 N/A N/A
AS SHOWN
ST-03
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT LOCATION: SAN ANDRES ST. ANGELES, PAMPANGA
J
JULIUS G. ORDOÑEZ PTR NO.: 9516889
SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS 2
J
OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE
CIVIL ENGINEER DATE ISSUED: 01-03-2023 WRITTEN CONSENT OF ARCHITECT/ENGINEER/DESIGNER OR AUTHOR OF SAID
DRAFT BY: CHECKED BY:
3 SHEET NO. TOTAL SHEET
DOCUMENTS.
PROJECT OWNER:
MR. & MRS. AUGUSTO SARMIENTO 4
PLACE ISSUED: PAMPANGA ADDRESS: ANGELES CITY, PAMPANGA DATE: DATE: 5
10 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14

LC L1 L2

0.75 LC OR 0.25 L1 0.25 L1 OR 0.75 LC 0.25 L2 OR 0.25 L1 SPLICE ZONE FOR 0.25 L2

A (GREATER GOVERNS) 0.25 L1 OR 0.25 L2


(GREATER GOVERNS)
(GREATER GOVERNS) GIRDER TOP BARS
A
SPLICE LENGTH SPLICE LENGTH
SEE TABLE SEE TABLE

EQ. EQ. EQ. EQ.

EQUAL

(SEE SCHEDULE)
EQUAL
2d EQ. EQ. 2d EQ. EQ.

D
NO SPLICE
SHALL BE
ALLOWED 2d
FROM THE

EQUAL
2d
B 0.165 L1 NO SPLICE
SHALL BE
FACE OF THE
SUPPORT B
ALLOWED 2d
FROM THE
50mm MAX. FACE OF THE
AT SUPPORT SUPPORT 0.165 L2

W
(SEE SCHEDULE)
HOOP REINFORCEMENT HOOP REINFORCEMENT HOOP REINFORCEMENT
SEE SCHEDULE SEE SCHEDULE SEE SCHEDULE

C C
SCALE : SCALE :
TYPICAL ONE-WAY REINFORCED
TYPICAL DUCTILE MOMENT FRAME GIRDER DETAIL
NOT TO SCALE CONCRETE SLAB DETAIL NOT TO SCALE

D D

E E

SCALE :
TYPICAL TWO-WAY REINFORCED
NOT TO SCALE CONCRETE SLAB DETAIL
F F

O.25 LC1 TOP BAR O.25 L O.25 L TOP BAR O.25 L O.25 L
SPLICE ZONE (TYP.) SPLICE ZONE
(TYP.)

G G

EQUAL

(SEE SCHEDULE)
EQUAL

D
0.165 0.165 0.165 0.165
LC1 LC1 LC2 LC2

BOTTOM BAR BOTTOM BAR


SPLICE ZONE (TYP.) SPLICE ZONE (TYP.) EQUAL

H H
40MM CLEAR MIN.
75MM CLEAR MAX.
W
LC1 LC2 LC1 OR LC2 (SEE SCHEDULE)
(CLEAR SPAN) (CLEAR SPAN)

I I
SCALE :
TYPICAL GRAVITY REINFORCED
NOT TO SCALE CONCRETE BEAM DETAIL
STRUCTURAL GENERAL NOTES
CERTIFIED BY: PRC REG. NO.: 0155062 REPUBLIC ACT 9266 SECTION 33 PROJECT TITLE: SHEET CONTENTS: REVISION NOTES: SHEET DETAIL:
DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DULY PROPOSED THREE STOREY
SIGNED, STAMPED OR SEALED AS INSTRUMENTS OF SERVICE, ARE THE NO. DESCRIPTION DATE CONTENT
TIN NO.: 342-848-717 PROPERTIES AND DOCUMENTS OF THE ARCHITECT/ENGINEER/DESIGNER RESIDENCE
1 N/A N/A
AS SHOWN
ST-04
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT LOCATION:
SAN ANDRES ST. ANGELES, PAMPANGA
J
JULIUS G. ORDOÑEZ PTR NO.: 9516889
SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF
SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS 2
J
OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE
CIVIL ENGINEER DATE ISSUED: 01-03-2023 WRITTEN CONSENT OF ARCHITECT/ENGINEER/DESIGNER OR AUTHOR OF SAID
DRAFT BY: CHECKED BY:
3 SHEET NO. TOTAL SHEET
DOCUMENTS.
PROJECT OWNER:
MR. & MRS. AUGUSTO SARMIENTO 4
PLACE ISSUED: PAMPANGA ADDRESS: ANGELES CITY, PAMPANGA DATE: DATE: 5
11 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14