Series 5800 Pump

Model: 58XX-XX01-B724
Flow Range: Open Flow = .64 - 1.12 GPM
At 130 PSI = .24 - .66

3.06 (584X-XX01-B724)
3.38 (585X-XX01-B724)
Completing the Part Number:
3.38 (587X-XX01-B724)
3.69 (588X-XX01-B724)
58XX-XX01-B724
Steel Mounting Plate (Other Types Available)
Desired Shut-off Pressure and Code
0 = None D = 50 PSI H = 90 PSI L = 130 PSI
A = 30 PSI E = 60 PSI I = 100 PSI
B = 40 PSI F = 70 PSI J = 110 PSI
3.6
6
C = 45 PSI G = 80 PSI K = 120 PSI
2.12 See Performance Data for Recommended By-pass
Pressure and Code
Pressure Control Options
0 = No Control (Waiver Required)
1 = Pressure Switch Control (Select Desired Shut off Pressure)
2 = Pressure Relief Valve (Select Recommended By-Pass Pressure)
Select Pumphead Model from Performance Data Chart
Porting Options
4 = Push-to-Connect Ports for 1/4” Tubing
1.36 (58XX-1X01-B724)
.23 (58XX-2X01-B724) 5 = Push-to-Connect Ports for 3/8” Tubing
7 = Push-to-Connect Ports for 5/16” Tubing
8 = 3/8” Female NPT Ports

.45 Specifications:
MOTOR:
TYPE: 24 VDC, Permanent Magnet,
Totally Enclosed, Non-Ventilated
2.72
LEADS: 14 AWG, 12” Long
TEMP. LIMITS: For User Safety, Optimal Performance, and Maximum Motor
Life, This Motor is Equipped with a Thermal Protector that
Limits the Motor Shell Temperature to 145°F (63°C), as
7.3 Shown on the Heat Rise Graph
DUTY CYCLE: See Heat Rise Graph
2.25

PUMP DESIGN: 3 Chamber Diaphragm Pump, Self-Priming, Capable of


Being Run Dry

TYPICAL APPLICATION: Industrial Grade Water Transfer

MATERIALS:
HOUSING: Nylon
VALVES: EPDM
3.18
DIAPHRAGM: Santoprene
FASTENERS: Stainless Steel, Zinc Plated Carbon Steel
4.00

LIQUID TEMPERATURE: 170°F (77°C) Max.

PRIMING CAPABILITIES:
58X0 58X1 58X2 58X3 58X4
PRIME (FT) 5 6 7 10 11
WEIGHT: 6 lbs.

Aquatec International
17422 Pullman DOCUMENT: DS58XX-XX01-B724
Irvine, CA 92614 REVISION: A
Sales: 949-225-2200 ECO: 6898
www.aquatec.com DATE: 5/26/16
Series 5800 Pump
Model: 58XX-XX01-B724
PERFORMANCE DATA
DISCHARGE PUMPHEAD MODEL RECOMMENDED
PRESSURE 58X0 58X1 58X2 58X3 58X4 BYPASS PRESSURE
FLOW CURRENT FLOW CURRENT FLOW CURRENT FLOW CURRENT FLOW CURRENT
PSI PSI CODE
(GPM) (AMPS) (GPM) (AMPS) (GPM) (AMPS) (GPM) (AMPS) (GPM) (AMPS)
130 0.24 1.62 0.32 2.02 0.47 2.72 0.57 3.13 0.66 3.74 160 P
120 0.25 1.57 0.34 1.94 0.48 2.60 0.58 2.95 0.68 3.53 150 N
110 0.26 1.52 0.35 1.85 0.50 2.43 0.60 2.80 0.71 3.33 140 M
100 0.28 1.45 0.36 1.76 0.52 2.30 0.62 2.65 0.74 3.15 130 L
90 0.29 1.39 0.37 1.67 0.53 2.16 0.64 2.50 0.76 2.93 120 K
80 0.30 1.33 0.38 1.59 0.54 2.02 0.65 3.34 0.78 2.72 110 J
70 0.32 1.25 0.40 1.50 0.56 1.87 0.66 2.06 0.80 2.52 100 I
60 0.34 1.18 0.42 1.42 0.59 1.74 0.67 2.02 0.81 2.32 90 H
50 0.38 1.11 0.51 1.31 0.63 1.61 0.71 1.88 0.83 2.13 80 G
40 0.47 1.00 0.61 1.17 0.69 1.43 0.83 1.68 0.91 1.93 70 F
30 0.52 0.89 0.64 1.03 0.78 1.25 0.89 1.45 1.00 1.70 60 E
20 0.56 0.76 0.66 0.87 0.81 1.03 0.92 1.21 1.05 1.42 50 D
10 0.59 0.62 0.69 0.72 0.83 0.84 0.97 0.98 1.08 1.19 40 B
OPEN 0.64 0.45 0.75 0.48 0.87 0.61 1.00 0.73 1.12 0.89 30 A

Performance measured with flooded inlet (0 PSI), 70°F (21°C) ambient and water temperature, and voltage controlled at 24 VDC. Positive
inlet pressure will increase the discharge pressure by a similar amount for a given flow. Maximum inlet pressure is 60 PSI.

Shaded area denotes continuous operation capability at designated pressure and current.

THERMAL
HEAT RISE
MOTOR SHELL TEMPERATURE (°F)

SHUT-OFF
180 TEMPERATURE
160
140
120
100 3.20 AMPS
80 3.74 AMPS
60
40
20
0
0 10 20 30 40 50 60 70 80 90 100 110 120
TIME (MINUTES)

The Shaded area in the charts above indicate performance points where pumps are capable of running without periodic cool down based
on current draw. Pumps in the unshaded areas require periodic shut down for motor cooling. Some applications require maximum flows
at high pressures for relatively short periods, so an explanation of thermal protection follows:
1. The Heat Rise graph plots the highest current that can run without ever leaving the shaded area, in this case, 3.2 amps. All pumps with lower
operating currents may also run continuously, unless the surrounding temperature exceeds 70°F (21°C).
2. The other curve shown is the highest flow and pressure model offered, the 58X4. At 130 PSI, this pump will flow .66 GPM, drawing 3.75 amps.
3. The motor driving all of these pump models has a built in thermal protector that will open, shutting off the pump, when the s urface temperature of
the motor heats to approximately 145°F. After the initial room temperature heat rise as shown, the model 58X4 reaches the shut off temperature
after about 30 minutes of run time, pumping about 20 gallons at 130 PSI.
4. Motors of this size and construction require 20 to 40 minutes of cooling time before the thermal protector closes and re-energizes the pump. Lower
current levels heat more slowly, allowing longer run times, but the cool down time still averages about 30 minutes at 70°F am bient temperature.
5. Your application may call for short bursts of water, consuming far less than the 30 minutes of sustained operation. Start-up current exceeds normal
running current, however, so cycling should be limited to 6 times per minute.

ALL PERFORMANCE AND HEAT RISE FIGURES ARE APPROXIMATE. ACTUAL VALUES WILL VARY WITH AMBIENT CONDITIONS.