Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

TIPPANNA NAYAKA

Electrical Engineer (Substation Automation)


Mob-8310345818 / 9535400578
Email-ntippanna@gmail.com
www.linkedin.com/in/tippanna-nayaka-24348520
#12 Anugraha1st main, Bro Garden Layout Nagasandra Metro- Bangalore-560073

Objective: Being an electrical engineer with 11+ years of experience always to be S.M.A.R.T(Specific, Measur-
able, Achievable, Relevant and Time-bound) to show my skill sets and will look forward to growing accordingly where
the place i would like to work .

Education:
 BE- in Electrical & Electronics Engineering from Basaveshwar Engineering college Bagalkot in the year 2009.
 2nd PUC Science from Government PU college Mundaragi in 2005.
 SSLC from Government Highschool Siddapur in 2003

Experience:
Hitachi energy India limited[2019-20XX]
Designation-Experienced Professional
Work- Looking into the CRP detailed engineering involving reading the CRP drawings/SLD/SAS architecture to
make line with the project specific requirements for making the configuration of IED’s application and SCADA applica-
tion. And involving in FAT activities with the customer for witnessing the panels. Providing the site support regarding
the technical issues found at site.

CADMAX SOLUTIONS 04/2017 - 03/2019


Bangalore , Karnataka
Work-CADMAXX Solutions is the Organization where it provides the employees to the clients to full
fill tier requirements by utilizing the its engineers in power systems and i was working as Design engi-
neer for the period of 2 years using the AutoCAD/E3 Zuken to prepare the schematics required in
substation design..

GLOBAL POWER SOLUTIONS [2015-2017]


Designation-Engineer Protection
Work-Continued to work as commissioning engineer with previous work experience.

AVANA ELECTROSYETMS PVT LIMITED [2010-2014]


Designation-Service Engineer
Work-Started career with this organization and learned a lot about power systems protection and
control by doing testing and commissioning of control and relays panels. I was doing relay/me-
ter/SCADA integration. Carried out Many projects commissioning actvities

Key accountabilities and responsibilities:


 Having the Commissioning Experience of transmission/Substation protection systems for volt-

ages up to 400 kV and above.

 Experience in reading/preparing Single Line Diagram, Substation Layout, Key Line Drawings

(SLD, KLD) and Cable protection.


 Parameterization and testing of numerical relays for protection. Calculation of relay settings

and preparation of logic files.

 Protection Relays Component testing / Final settings Implementation, Line differential End to

End test, Cable differential Stability test, Bus Bar Primary stability test and other protections

too(Generator ,Line, Transformer, Busbar and BCU’s.

 Detailed study of customer specification, SLD & Design documents review for preparation of

check point for testing activities related to protection and control system.

 Testing of Relay Protection Function & Scheme checking as per TRIP MATRIX.

 Preparation of OCC files, test plans for Numerical relay test kits using Omicron-Test Universe.

 Point to Point test of Protection Trip / Alarms / Events / Measurements & report

documentation.

 Technical coordination for FAT.

 Responsible for ensuring that specification is fulfilled in respect of the technical offer.

 Ensuring project execution is carried out fulfilling internal processes and guidelines.

 Ensuring experience and learnings during the project execution are shared with colleagues

within the same unit (Sales, B&P, PMs, Engineering, Testing, Commissioning)

 Coordination and Conducting Integrated FAT & SAT with witnessing team and Utility Client for

Protection Relay Panels and Substation Products

 Experience in the preparation of detailed electrical schematic diagrams for substation Protec-

tion and Control systems.

 Understanding the customer requirements as per project specific.

 Proven ability of communicating complex technical or commercial issues to peers or senior

managers.

 Knowledge On IEC61850 communication protocols (101/104, PRP/HSR/RSTP)

 Design & documentation.

 Maintaining the skill level of the whole engineering team.

 Contribute to the overall quality of the organization in the engineering space.

 Ensuring high performance on a variety of platforms

 Creating standard protocols & documentation for repeat use.

 Participation in Pre-FAT, FAT, SAT etc

 Monitor Compliance to process/Targets.


 Maintaining Cost, quality & schedule as per contractual terms

 Knowledge on Safety and integrity (Completed all internal safety trainings and six sigma yel-

low belt)

 Having hands-on experience on programming, design, application programming.

Secondary Test Kits used.


 Doble-F600/F6test 4.0
 Omicron-CMC256/356

Software Knowledge
Basics of C
XML Scripting, SCIL (Supervisory control implementation Language used in Micro SCADA)
VBA Scripting
MS Office, PowerPoint, and Excel usage.

Protocols/Networking Knowledge
IEC61850, IEC101/104
SNMP/HSR/RSTP/PRP
Gateway/RHMI
RTU
Cyber Security-

Products worked With.


GE/Schnieder/ABB/Hitachi/Alstom/SEL make IED’s.
Micro SCADA, Micro SCADA X

Product tool used.


PCM600
S1 agile
Micom S1 studio/Easergy studio
Quickset Accselerator
Digsi4/5
GE Ener vista

Hobbies
Watching movies & Sports and playing cricket etc,

The information provided above are true and correct to the best of my knowledge.

Thank you. Date:25-03-2024

You might also like