Material : Concrete

Supplier : PT. Merak Jaya Beton


Test Type : Compressive Strength Test
Testing Location : Laboratorium Pengujian PT. Merak Jaya Beton Plant Cengkareng
Standard Code : SNI 03-1974-1990

Testing Item
Age of
Compressive Strength
No Sample Code Speciment
(MPa)
(days)
Result Standard Status
1 WACO-BMR / PILE CAP TC / FC40 / MJB 7 30.59 26 OK

Age of Testing Item


No Sample Code Speciment Compressive Strength
(days) Result Standard Status
1 WACO-BMR / PILE CAP TC / FC40 / MJB 14 38.38 35.2 OK