Download as pdf or txt
Download as pdf or txt
You are on page 1of 193

Antriebs- und Steuerungstechnik

Typ3 osa/PNC

Error Messages

102
Edition
Typ3 osa/PNC

Error Messages

1070 073 799-102 (02.05) GB

Software release: V7.2

E 2001 – 2002

by Bosch Rexroth AG, Erbach / Germany


All rights reserved, including applications for protective rights.
Reproduction or distribution by any means subject to our prior written permission.

Discretionary charge 12.– EUR


Contents V

Contents

Page

1 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1


1.1 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1
1.2 Qualified personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2
1.3 Safety markings on products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–3
1.4 Safety instructions in this manual . . . . . . . . . . . . . . . . . . . . . . . . . 1–4
1.5 Safety instructions for the described product . . . . . . . . . . . . . . . . 1–5
1.6 Documentation, software release and trademarks . . . . . . . . . . . 1–7

2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–1
2.1 Error classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–1
2.2 Error displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2
2.2.1 Visualization in NC status bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2
2.2.2 Visualization in the Information-window . . . . . . . . . . . . . . . . . . . . 2–3
2.2.3 Displays in the permanent logbook . . . . . . . . . . . . . . . . . . . . . . . . 2–7
2.2.4 7-segment display H1 (osa master module) . . . . . . . . . . . . . . . . . 2–8

3 Messages, warnings, errors in the Info-window . 3–1


3.1 Structure of the error table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–1
3.2 Error table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–2

A Annex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A–1
A.1 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A–1
A.2 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A–2

1070 073 799-102 (02.05) GB


VI Contents

1070 073 799-102 (02.05) GB


Safety Instructions 1–1

1 Safety Instructions
This manual will help you understand the errors, warnings and messages
that may be displayed on Typ3 osa and PNC controls. Keep this manual in a
place where it is always accessible to all users.

1.1 Intended use


This manual contains information required for the proper use of this product.
However, for reasons of structural clarity, the manual cannot provide ex-
haustive details regarding all available combinations of functional options.
Similarly, it is feasible to consider every conceivable integration or operating
scenario within the confines of this manual.

The Typ3 osa and PNC controls are used to


D activate feed drives, spindles and auxiliary axes of a machine tool via
SERCOS interface for the purpose of guiding a processing tool along a
programmed path to process a workpiece (CNC). Furthermore, a PLC is
required with appropriate I/O components which – in communication with
the actual CNC – controls the machine processing cycles holistically and
acts as a technical safety monitor.
D program contours and the processing technology (path feedrate, spindle
speed, tool change) of a workpiece.

Any other application is deemed improper use!

The products described hereunder


D have been developed, manufactured, tested and documented in com-
pliance with the safety standards. These products pose no danger to per-
sons or property if they are used in accordance with the handling
stipulations and safety notes prescribed for their configuration, mount-
ing, and proper operation.
D comply with the requirements of
D the EMC Directives (89/336/EEC, 93/68/EEC and 93/44/EEC)
D the Low-Voltage Directive (73/23/EEC)
D the harmonized standards EN 50081-2 and EN 50082-2
D are designed for operation in industrial environments, i.e.
D no direct connection to public low-voltage power supply,
D connection to the medium- or high-voltage system via a transformer.
In residential environments, in trade and commerce as well as small en-
terprises class A equipment may only be used if the following warning is
attached:

. This is a Class A device. In a residential area, this device may cause


radio interference. In such case, the user may be required to introduce
suitable countermeasures, and to bear the cost of the same.

The faultless, safe functioning of the product requires proper transport, stor-
age, erection and installation as well as careful operation.

1070 073 799-102 (02.05) GB


1–2 Safety Instructions

1.2 Qualified personnel

The requirements as to qualified personnel depend on the qualification pro-


files described by ZVEI (central association of the electrical industry) and
VDMA (association of German machine and plant builders) in:
Weiterbildung in der Automatisierungstechnik
edited by: ZVEI and VDMA
MaschinenbauVerlag
Postfach 71 08 64
D-60498 Frankfurt.

This instruction manual is specifically designed for skilled NC workers. They


require special skills in handling the Typ3 osa or PNC.

Programming, start and operation as well as the modification of program pa-


rameters is reserved to properly trained personnel! This personnel must be
able to judge potential hazards arising from programming, program changes
and in general from the mechanical, electrical, or electronic equipment.

Interventions in the hardware and software of our products, unless de-


scribed otherwise in this manual, are reserved to our specialized personnel.

Tampering with the hardware or software, ignoring warning signs attached to


the components, or non-compliance with the warning notes given in this
manual may result in serious bodily injury or material damage.

Only electrotechnicians as recognized under IEV 826-09-01 (modified) who


are familiar with the contents of this manual may install and service the prod-
ucts described.

Such personnel are


D those who, being well trained and experienced in their field and familiar
with the relevant norms, are able to analyze the jobs being carried out
and recognize any hazards which may have arisen.
D those who have acquired the same amount of expert knowledge through
years of experience that would normally be acquired through formal tech-
nical training.

With regard to the foregoing, please note our comprehensive training pro-
gram. For up-to-date information, web shop for teachware and online sem-
inar booking, please refer to http://www.bosch.de/at/didactic or call our
training center at (+49) 60 62 78-258.

1070 073 799-102 (02.05) GB


Safety Instructions 1–3

1.3 Safety markings on products

Warning of dangerous electrical voltage!

DANGER! Corrosive battery acid!

Electrostatically sensitive components!

Hazardous light emissions


(optical fibre cable emitters)!

Disconnect mains power before opening!

Lug for connecting PE conductor only!

Connection of shield conductor only

1070 073 799-102 (02.05) GB


1–4 Safety Instructions

1.4 Safety instructions in this manual

DANGEROUS ELECTRICAL VOLTAGE


This symbol is used to warn of a dangerous electrical voltage. The fail-
ure to observe the instructions in this manual in whole or in part may result
in personal injury.

DANGER
This symbol is used wherever insufficient or lacking compliance with in-
structions may result in personal injury.

CAUTION
This symbol is used wherever insufficient or lacking compliance with in-
structions may result in damage to equipment or data files.

. This symbol is used to draw the user’s attention to special circumstances.

L This symbol is used if user activities are required.

1070 073 799-102 (02.05) GB


Safety Instructions 1–5

1.5 Safety instructions for the described product

DANGER
Danger of life through inadequate EMERGENCY-STOP devices!
EMERGENCY-STOP devices must be active and within reach in all
system modes. Releasing an EMERGENCY-STOP device must not
result in an uncontrolled restart of the system!
First check the EMERGENCY-STOP circuit, then switch the system
on!

DANGER
Risk of personal injury and equipment damage!
Always subject new programmes to initial tests while inhibiting axis
movements. For this purpose, as a function of the AUTOMATIC
mode, the controller provides the option to block axis movements or
auxiliary functions by means of special softkey commands.

DANGER
Incorrect or undesired control unit response!
Rexroth accepts no liability for damage resulting from the execution
of an NC program, an individual NC block or the manual movement
of axes!
Furthermore, Rexroth accepts no liability for consequential damage
which could have been avoided by programming the PLC appropri-
ately!

DANGER
Retrofits or modifications may adversely affect the safety of the
products described!
The consequences may include severe injury, damage to equipment,
or environmental hazards. Possible retrofits or modifications to the
system using third-party equipment therefore have to be approved
by Rexroth.

DANGEROUS ELECTRICAL VOLTAGE


Unless described otherwise, maintenance works must be performed
on inactive systems! The system must be protected against unau-
thorized or accidental reclosing.

Measuring or test activities on the live system are reserved to quali-


fied electrical personnel!

1070 073 799-102 (02.05) GB


1–6 Safety Instructions

DANGER
Tool or axis movements!
Feed and spindle motors generate very powerful mechanical forces
and can accelerate very quickly due to their high dynamics.
D Always stay outside the danger area of an active machine tool!
D Never deactivate safety-relevant functions!
D Report any malfunction of the unit to your servicing and repairs
department immediately!

CAUTION
Use only spare parts approved by Rexroth!

CAUTION
Observe all precautions for ESD protection when handling modules
and components! Avoid electrostatic discharge!

The following protective measures must be observed for modules and com-
ponents sensitive to electrostatic discharge (ESD)!
D Personnel responsible for storage, transport, and handling must have
training in ESD protection.
D ESD-sensitive components must be stored and transported in the pre-
scribed protective packaging.
D ESD-sensitive components may only be handled at special ESD-work-
places.
D Personnel, working surfaces, as well as all equipment and tools which
may come into contact with ESD-sensitive components must have the
same potential (e.g. by grounding).
D Wear an approved grounding bracelet. The grounding bracelet must be
connected with the working surface through a cable with an integrated
1 MW resistor.
D ESD-sensitive components may by no means come into contact with
chargeable objects, including most plastic materials.
D When ESD-sensitive components are installed in or removed from equip-
ment, the equipment must be de-energized.

1070 073 799-102 (02.05) GB


Safety Instructions 1–7

1.6 Documentation, software release and trademarks

Documentation
The present manual provides the user with comprehensive information
about the error messages of Typ3 osa and PNC.

Overview of available documentation Part no.


German English
Typ3 osa – Connectivity Manual for project 1070 073 704 1070 073 736
engineering and maintenance
Typ3 osa – Software installation 1070 073 796 1070 073 797
PNC – Software installation 1070 073 882 –
Function description 1070 073 870 1070 073 871
MACODA 1070 073 705 1070 073 742
Operation and configuration of the machine pa-
rameters
Operating instructions 1070 073 726 1070 073 739
Standard operator interface
Operating instructions – Diagnostics Tools 1070 073 779 1070 073 780
Error Messages 1070 073 798 1070 073 799
PLC project planning manual, 1070 073 728 1070 073 741
Software interfaces of the integrated PLC
iPCL system description and 1070 073 874 1070 073 875
programming manual
ICL700 system description (Typ3 osa only), 1070 073 706 1070 073 737
Program structure of the integrated PLC
ICL700
DIN programming manual 1070 073 725 1070 073 738
for programming to DIN 66025
CPL programming manual 1070 073 727 1070 073 740
CPL Debugger Operating Instructions 1070 073 872 –
Tool Management – Parameterization 1070 073 782 1070 073 793
Software PLC 1070 073 783 1070 073 792
Development environment for Windows NT
Measuring cycles for 1070 073 788 1070 073 789
touch-trigger switching probes
Universal Milling Cycles – 1070 073 795

. In this manual the floppy disk drive always uses drive letter A:, and the
hard disk drive always uses drive letter C:.

Special keys or key combinations are shown enclosed in pointed brackets:


D Named keys: e.g., <Enter>, <PgUp>, <Del>
D Key combinations (pressed simultaneously): e.g., <Ctrl> + <PgUp>

1070 073 799-102 (02.05) GB


1–8 Safety Instructions

Release

. The descriptive information contained in this manual applies to:


Software release: V7.2

The current release number of the individual software modules can be


viewed by selecting the ’Control-Diagnostics’ softkey in the ’Diagnostics’
group operating mode.

The software version of Windows95 or WindowsNT may be displayed as fol-


lows:
1. Click the right mouse button on the My Computer icon on your desktop.
2. Select Properties.

Trademarks
All trademarks of software installed on Rexroth products upon delivery are
the property of the respective manufacturer.

Upon delivery, all installed software is copyright-protected. The software


may only be reproduced with the approval of Rexroth or in accordance with
the license agreement of the respective manufacturer.

MS-DOSr and Windowst are registered trademarks of Microsoft Corpo-


ration.

PROFIBUSr is a registered trademark of the PROFIBUS Nutzerorganisa-


tion e.V. (user organization).

SERCOS interfacet is a registered trademark of the SERCOS interface


Joint VDW/ZVEI Working Committee.

1070 073 799-102 (02.05) GB


Overview 2–1

2 Overview

2.1 Error classes


Messages, warnings and errors of Typ3 osa and PNC may originate in differ-
ent areas, resulting in the following error classes:

Type Error class Description


Error Serious system error*) Internal error preventing further operation of the controller.
Minor system error*) Internal error that renders a subsystem of the controller inopera-
tive.
Servo loop and drive fault Error in the ”Drive interface” area .
Hardware error A hardware component of the controller is defective or disturbed.
PLC error Error originating from the PLC.
Part program error Error when processing a part program.
MMI error Error in the Bosch man-machine interface.
DNC error Error in the ”DNC” area.
Interface error Error in the ”PROFIBUS-DP”, ”Ethernet port” or ”Serial port”
areas.
Machine error Error in the MSD (machine status display, machine manufacturer-
specific) area.
Warnings Core system warning Warning in a subsystem of the controller.
Interface warning Warning in the ”PROFIBUS-DP”, ”Ethernet port” or ”Serial port”
areas.
Machine Warning Warning in the MSD (machine status display, machine manufac-
turer-specific) area.
Messages Programmed oper. instruc- Instruction programmed in the part program:
tion S (MSG,)...
S PRN#(0,...
Machine oper. instruction Instruction from the MSD area (machine status display, machine
manufacturer-specific).

. *) When a system error has occurred, please call the Rexroth service.

1070 073 799-102 (02.05) GB


2–2 Overview

2.2 Error displays


Messages, warnings and errors are displayed in various fields of the user
interface of the controls:

Typ3 osa, PNC Type of fault Information displayed


user interface
(man-machine in-
terface)
NC status line D Messages D Error symbol
D Warnings D Error text from MSD area
D Errors only

Info dialog D Messages D Error number


D Warnings D Error text including relevant
D Errors parameter

Logbook D System errors D Error number and additional


information (task, call chain)
The error text itself is not dis-
played, also refer to the tables in
this manual.

2.2.1 Visualization in NC status bar


During an error the NC status bar shows a symbol and a corresponding text
from the machine status display (MSD) area. This is independent of the se-
lected channel and the filter function.
You will get detailed information in the Information-window.

$1: Station 0012 Feed inhibit 30.07.01


NC: Typ3osa !? Axis 1 12:15:22

Message awaiting attention Field with green background


! – flashing or static –

Warning awaiting attention Field with yellow background


? – flashing or static –
Error or system error Field with red background
has occurred, – flashing or static –

Feed inhibit Instruction window for pending messages (field with green background)
Axis 1
warnings (field with yellow background)
or errors (field with red background).

Meaning of the static or flashing displays:


D flashing: The Information-window was not opened even after
the occurrence of the event.
D Static: The Information-window was already opened and
also closed after the occurrence of the event.

1070 073 799-102 (02.05) GB


Overview 2–3

2.2.2 Visualization in the Information-window

The Information-window contains a detailed display of the messages, warn-


ings and errors.

You can open the Information-window  with the “Info” key:

$1: Station 0012 30.07.01


Displays, which event groups are dis-
played (also refer to Check -Softkeys “Er-
NC: Typ3osa ? 12:15:22

Information
ror”, “Warning” and “Message”)
Errors Warnings Messages

No $ Date Time (ms) Description

Column headings: 387 1 30.07.01 12:11:00 (340)Syntax error in case of “9M119 k” –> MDI
No: Error number 884 – 29.07.01 12:30:12 (210) Disturbance in transmission track
$: Channel, in which the 884 – 29.07.01 12:25:56 (490) Disturbance in transmission track
event has occurred
Date: Date on which the
event has occurred

Time: Time of

 
occurrence of event.
(ms): Milli-seconds.
Additional Time. Selected information
9M119 k” –> MDI
Description: Information about the
event. Syntax error for “9M119 k” –> MDI Number: 387
Category: Parts program error
? Channel:
Date:
$1
30.07.01
Time: 12:11:00

Display Dilplay Delete


Error Warning Message Update– lLast Set
Details Info filter
Info

Several events that have occurred are presented in the form of a list in the
display area  . Select a list entry with the by cursor keys. Additional in-
formation about the selected event in the list is displayed in the area  and
.

Last events
Display With the “Display last infos” softkey “in the highest operating level of the In-
Last
Info
formation-window, the control system displays the break-up of the errors,
warnings and messages that occurred last:
D Event in the plain language
D Event number
D Event class in the plain language
D Channel, in which the event has occurred and
D Time of occurrence of the event.

. This display is automatically updated when a new error occurs.

1070 073 799-102 (02.05) GB


2–4 Overview

$1: Station 0012


NC: Typ3osa ? 30.07.01
12:15:22
Information

Last error

Program selection error “/usr/user” Number: 1341


is a file directory. –> RESET Class: Parts program error
Channel: *1
Date: 30.07.01
Time: 12:14:22 PM

Last warning

Feed Hold Number: 562


Class: machine warning
? Channel: –
Date: 30.07.01
Time: 12:14:23 PM

Last message

Class:
SW-Channel:
Date
Time

Display Display
OK Error Warning
details Details

The control system provides more information on occurred errors and


warnings in the form of
D explanation about the cause
D instructions for elimination
Display
Error For detailed information about the last occurred events, select the softkeys:
Details
”Display Error Details” or
Display ”Display Warning Details”.
Warning
Details
$1: Station 0012 30.07.01
NC: Typ3osa 12:15:22

Show details

Selected Last error


information
Number: 1341
Program selection error “/usr/user”
Class: Parts program error
is a file directory. –> RESET Channel: *1
Date: 30.07.01
Time: 12:14:22 PM

Cause

A parts program that does not exist was selected.

Elimination

Repeat program selection with a program

OK

1070 073 799-102 (02.05) GB


Overview 2–5

Configuring the contents


of the Information window
The list of all events may be limited:

Selection:

F1 F2 F3 F4 F5 F6 F7 F8
Display Display Delete
Error Warning Message Update Last Set
Details Info filter
Info

You are able to –


D display or mask errors in the list
Error

D display or mask warnings in the list


Warning

D display or mask messages in the list


Message

Set filter D The ”Set filter” softkey determines the scope of display specific to the
channel. You can select whether the events of all or individual chan-
nels should be displayed. You reach the next softkey-level (see dia-
gram):

$1: Station 0012


NC: Typ3osa ? 30.07.01
12:15:22
Information

Errors Warnings Messages Filter active 


No $ Date Time (ms) Description

387 1 30.07.01 12:11:00 (340)Syntax error in case of “9M119 k” –> MDI


884 – 30.07.01 12:00:00 (210) Disturbance in transmission track
884 – 30.07.01 10:25:56 (490) Disturbance in transmission track

9M119 k” –> MDI


Selected information

Syntax error for “9M119 k” –> MDI Number: 387


Category: Parts program error
? Channel:
Date:
$1
30.07.01
Time: 12:11:00

Filter
Channel Filter 

At this point you can –


D Activate the filter with the ”Filter”  softkey. In addition to this, the active
Filter
filter function is displayed in the right corner of the “Event group display”
(errors, warnings,...) with the note “Filter is active”  .

1070 073 799-102 (02.05) GB


2–6 Overview

Filter
D using the “Filter channel” softkey determine the channel(s), for which the
channel events should be displayed in the Information-window. The selection is
active only when the “Filter” softkey is active.
Select the individual channels in the dialog menu “Filter channel” with
the by cursor keys and the <space>key.

$1: Station 0012 30.07.01


NC: Typ3osa ? 12:15:22

Information

Errors Warnings Messages Filter active

Filter channel Select class


No $ Date Time (mS) Description

Available Channels:
387 1 22.09.00 13:11:00 (340)Syntax error in case of “9M119 k” –> MDI
884 – 01.10.93 12:30:12 (210) Disturbance in transmission track
$ 0: Switching function
884 – $ 01.10.93
1: 12:25:56 (490) Disturbance in transmission track
$ 2:

9M119 k” –> MDI


Selected entry

Syntax error for “9M119 k” –> MDI Number: 387


Category: Parts program error
Channel: $1
Date: 30.07.01
Time: 11:11:00 AM

OK All All
ON OFF

Details about events in the Information-window


Show Select an event in the list of events in the Information-window and press the
details ”Show details” softkey. You will then get additional information about the
cause and elimination:
$1: Station 0012 30.07.01
NC: Typ3osa 12:15:22
Show details

Selected Selected information


information
Program selection error “/usr/user” Number: 1341
is a file directory. –> RESET Class: Parts program error
Channel: *1
Date: 30.07.01
Time: 12:14:22 PM

Cause

A parts program that does not exist was selected.

Elimination

Repeat program selection with a program

OK First Previous Next Last


entry entry entry entry

. For more instructions concerning operation, please refer to the


manual ”Operating instructions, Standard operator interface”.

1070 073 799-102 (02.05) GB


Overview 2–7

2.2.3 Displays in the permanent logbook

The logbook is an internal ring memory in which the control stores all system
errors.

Selection:

F2
Control
diagnostics

F7
Logbook

Press the ”Logbook” softkey to output the ring memory contents chronologi-
cally to a log file with the most recent entry at the beginning of the file. The file
contents will be displayed.

$1: Station 0012 30.07.01


NC: Typ3osa 12:15:22
B: Diagnostics/Control/Logbook

Log-book file (Read-only)

+–> C = Major system error, U = Minor system error


I No Date Time (ms) Cpu:S1 Task Id Error text

OK

1070 073 799-102 (02.05) GB


2–8 Overview

2.2.4 7-segment display H1 (osa master module)

Ethernet display
An Ethernet connection of the osa master module, e.g. with a PC control
panel, is indicated by the decimal point on the 7-segment display: this point is
lit for at least 0.2 s for each data package transmitted via Ethernet.
If the Ethernet transmission is defective or non-existent, the decimal point
will not be lit for a prolonged period of time.

Front view of osa master (SNCI)

7-segment display

Switch S1

Diagnostics display H1

Decimal point for


Ethernet transmission

1070 073 799-102 (02.05) GB


Overview 2–9

Error display
During certain phases, or after errors which prevent a display on the screen,
Typ3 osa may visualize system errors on the 7-segment display.

A complete error message comprises a sequence of alphanumeric charac-


ters according to the following schematic:

0.5 s 0.5 s 2s 1s 1s

’ ’ ’ ’ ’ ...

Module number 0

Error type when


loading software Error number

0.5 s 0.5 s 1s 2s 1s 1s

’ ’ ... ’ ’ ’ ’ ...

Number of module in which the


error occurred. The last digit
appears for 2 s.

Error type when boot-


ing Error number

D The letters P, E or F, E are displayed for 0.5 s each one after the other
without a dark pause between the letters.
D No pause between letters and module number (number of the slot of the
module producing the error).
D Afterwards, the module number will be displayed, with a dark pause of
0.5 s between numbers if several modules are concerned. The last mod-
ule number will be displayed for 2 s.
(Module number 0 only for PE errors)
D After a dark pause of 1.0 s, the error number is indicated, a maximum of 9
digits are possible:
Each digit is displayed for 1 s with a dark pause of 0.5 s between digits.
D The display is concluded by a dark pause of 2 s.

The whole display will be permanently repeated up to the next RESET.

. The 7-segment display only shows the error numbers of system errors.
Please call the Rexroth service in this case.

1070 073 799-102 (02.05) GB


2–10 Overview

Notes:

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–1

3 Messages, warnings, errors in the Info-window


The table provided in Section 3.2 contains the messages, warnings and er-
rors of the operating software and the operating system software (PXROS)
which are shown in detail in the Information-window.

Some of the error texts contain wildcards for parameters which will be re-
placed with the parameters transferred when the error routine is called up
and the text is displayed.

3.1 Structure of the error table

The table has been sorted according to error numbers in ascending order
and contains the following information

D No: Error number, 4 digits


D Error text: Text shown in the Info-window.
The error text contains wildcards for parameters (%s,
%d, %c, %f and %x), which will be replaced with the rele-
vant parameters when the error occurs (e.g. axis ad-
dress, file name, ...).

D Cause: Possible cause of the error.


As of software version V6.x, the cause of the error will
also be displayed in the Info-window.
Errors may be caused indirectly by certain circum-
stances, so that the cause displayed here is not neces-
sarily applicable. Please contact the Bosch service in
cases of doubt.

D Correction: Information and measures for error correction.


As of software version V6.x, the correction of the error
will also be displayed in the Info-window.
Please perform the recommended corrective action in
order to return your system to an operative condition.

D Error class: Assignment to error class.


The error class indicates the controller area that gener-
ated the error.
For a description of error classes, refer to Section 2.1.

D Reset mode: Measures for resetting the error display.


By these measures, the error display will be deleted from
the status line and the Info-window. As soon as the error
has been corrected, the system will be rendered opera-
tive again.

1070 073 799-102 (02.05) GB


3–2 Messages, warnings, errors in the Info-window

3.2 Error table


You will find abbreviated entries in the table for the following explanations:

Correction Explanation
(abbreviated entry)
No error recovery pos- Please report error data and detailed software ver-
sible! sion to the after sales service of the NC manufac-
turer.
Correct When the error has been corrected, select part pro-
programming error gram again and restart it, if necessary.

Reset mode Explanation


(abbreviated entry)
System Restart Resets error condition with System Restart softkey
from the ”DIAGNOSTICS” group operating mode, or
with the RESET button on the osa dc I/O module

By resetting the error display, the display is cleared,


however, the parts of the controller in question still
fail to work properly!
Reset current channel Resets error condition by resetting the channel that is
currently selected. This measure is performed by
pressing the Channel reset softkey in the
”AUTOMATIC” group operating mode.
Reset all channels Resets error condition by resetting all channels. To
be performed by pressing the Control Reset softkey
in the ”DIAGNOSTICS” group operating mode.

No Error text Cause Correction Error class Reset mode


1 Serious debug mode er- Internal software error. No error recovery pos- Serious system System Restart
ror in file %s. sible! error
2 Minor debug mode error Internal software error. No error recovery pos- Minor system System Restart
in file %s. sible! error
3 Structure of system de- Internal software error. No error recovery pos- Serious system System Restart
fined task data isn’t %d sible! error
bytes large.
4 Function PxTaskCreate Internal software error. No error recovery pos- Serious system System Restart
returns with error number sible! error
%d.
5 Rau-Offset not TID-page- Internal software error. No error recovery pos- Serious system System Restart
size-aligned. sible! error
6 Overflow of 16 Bit adder Internal software error. No error recovery pos- Serious system System Restart
of Rau offset and RAU sible! error
register.
7 Assigned idle task stor- Internal software error. No error recovery pos- Serious system System Restart
age too small (%d instead sible! error
of %d).
8 Idle task stack not TID- Internal software error. No error recovery pos- Serious system System Restart
pagesize aligned. sible! error
9 Unknown task parameter Internal software error. No error recovery pos- Serious system System Restart
%d for task %s. sible! error

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–3

No Error text Cause Correction Error class Reset mode


10 End of stack could not be Internal software error. No error recovery pos- Serious system System Restart
written into the task table sible! error
for %s.
11 TID number for task %s Internal software error. No error recovery pos- Serious system System Restart
not found. sible! error
12 Task-Id for task %s not Internal software error. No error recovery pos- Serious system System Restart
found. sible! error
13 Task name %s not found Internal software error. No error recovery pos- Serious system System Restart
in the task table. sible! error
14 Function PxObjRequest Internal software error. No error recovery pos- Serious system System Restart
returns with error number sible! error
%d.
15 Function PSemaCreate Internal software error. No error recovery pos- Serious system System Restart
returns with error number sible! error
%d.
16 Function Pxr_GetTidProt- Internal software error. No error recovery pos- Serious system System Restart
to Mem returns with error sible! error
19 number %d.
20 PXROS no longer uses Internal software error. No error recovery pos- Serious system System Restart
%d bytes for memory sible! error
management per block.
21 Memory area for TID Internal software error. No error recovery pos- Serious system System Restart
protection outside of sible! error
Pxr_mc_protected class.
22 TID protection can only Internal software error. No error recovery pos- Serious system System Restart
be modified if preceded sible! error
by own Task-Id or No-
Prot-TID.
23 Function pxr_tid_Init re- Internal software error. No error recovery pos- Serious system System Restart
turns with error number sible! error
%d.
24 Memory area of size zero Internal software error. No error recovery pos- Serious system System Restart
requested. sible! error
25 FPU registers were modi- Floating point operands No error recovery pos- Serious system System Restart
fied in interrupt %d, but are used in this interrupt, sible! error
not saved. but the interrupt routine is
not prepared to use float-
ing point operands.
26 Block pointer for a me- Internal software error. No error recovery pos- Serious system System Restart
mory block does not point sible! error
to the beginning of the
block.
27 Priority for task %s not Internal software error. No error recovery pos- Serious system System Restart
found. sible! error
28 No main routine has been Internal software error. No error recovery pos- Serious system System Restart
specified for task %s. sible! error
30 Tid number for task %s Internal system error! No error recovery pos- Serious system System Restart
could not be written into sible! error
the task table.
31 Invalid TID write protec- Internal system error! No error recovery pos- Serious system System Restart
tion identification %d in sible! error
task table for task %s.
32 Overflow of TID write Internal software error. No error recovery pos- Serious system System Restart
protection numbers. sible! error

1070 073 799-102 (02.05) GB


3–4 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


33 Error number %d during During a call of a PXROS No error recovery pos- Serious system System Restart
call of a PXROS routine. service a serious error of sible! error
internal data structure
was detected. This error
cannot be removed. The
PXROS kernel can no
longer function. This is
usually caused by prob-
lems with internal system
objects such as de-
stroyed task control
blocks, mailboxes or
messages or by problems
with corrupted memory
classes. All serious
PXROS errors lead to the
critical system error 33.
The error text describes
the reason for system er-
ror 33.
34 Block pointer for a me- Internal software error. No error recovery pos- Serious system System Restart
to mory block does not point sible! error
35 to the beginning of the
block.
36 Function pxr_tid_Init re- Internal software error. No error recovery pos- Serious system System Restart
turns with error number sible! error
%d.
37 End of stack could not be Internal software error. No error recovery pos- Serious system System Restart
written into the task table sible! error
for %s.
38 NFS-Cache cannot be A excessive value for the Change the MACODA Core system in the Info dia-
installed. buffer size was defined in parameter warning log with softkey
MACODA parameter ”Delete warn-
308000002. ings”
39 The PLC user program is During startup of the NC Load PLC user program PLC error Restart of PLC
missing or defective. the PLC user program is from the control or by program
missing or defective. means of the program-
ming device and switch
the control to RUN state
or if a PLC user program
exists in the internal FE-
PROM or on the PCMCIA
card, start the control with
switch position ”6”.
ATTENTION: Data which
are not saved in the FE-
PROM will be lost after
startup.
40 NCB: No memory during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
41 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
42 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
43 NCB: Startup synchro- Internal software error. No error recovery pos- Serious system System Restart
nisation. sible! error
44 NCB: Startup Nameser- Internal software error. No error recovery pos- Serious system System Restart
verInit %d. sible! error

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–5

No Error text Cause Correction Error class Reset mode


45 NCB: Startup MsgRelSer- Internal software error. No error recovery pos- Serious system System Restart
verInit %d. sible! error
46 NCB: Startup Prevserver- Internal software error. No error recovery pos- Serious system System Restart
Init %d. sible! error
47 NCB: Startup ChansrvInit Internal software error. No error recovery pos- Serious system System Restart
%d. sible! error
48 NCB: Event DEBUG er- Internal software error. No error recovery pos- Serious system System Restart
ror. sible! error
49 Function Pxr_GetTidProt- Internal system error! No error recovery pos- Serious system System Restart
Mem returns with error sible! error
number %d.
50 ProfiBus FMS error. Internal system error! No error recovery pos- Minor system System Restart
Function %d, number %d. sible! error
51 Invalid plane selected: The chosen working Please check the axes Part program Reset of current
axis address missing! plane cannot be built up classifications of your error channel
with the axes configured channel axes. Mind an
in the concerning channel eventual axes change.
because they do not have
the needed axes classifi-
cations.
52 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
53 NCB: No memory during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
54 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
55 NCB: Function cannot be Internal software error. No error recovery pos- Serious system System Restart
canceled. sible! error
56 NCB: Startup inconsis- Internal software error. No error recovery pos- Serious system System Restart
tency. sible! error
57 NCB: Receive error. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
58
59 NCB: Startup inconsis- Internal software error. No error recovery pos- Serious system System Restart
tency. sible! error
60 NCB: Function cannot be Internal software error. No error recovery pos- Serious system System Restart
to canceled. sible! error
62
63 NCB: Startup synchro- Internal software error. No error recovery pos- Serious system System Restart
nisation. sible! error
64 NCB: Function cannot be Internal software error. No error recovery pos- Serious system System Restart
to canceled. sible! error
65
66 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
67 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
68 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
to NCB startup. sible! error
69
70 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
to during NCB startup. sible! error
71

1070 073 799-102 (02.05) GB


3–6 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


72 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
to NCB startup. sible! error
73
74 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
75 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
76 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
77 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
78 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
to during NCB startup. sible! error
79
80 NCB: Startup synchro- Internal software error. No error recovery pos- Serious system System Restart
nisation. sible! error
81 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
82 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
83 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
to during NCB startup. sible! error
87
88 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
89 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
to during NCB startup. sible! error
91
92 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
93 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
to during NCB startup. sible! error
94
95 NCB: Startup inconsis- Internal software error. No error recovery pos- Serious system System Restart
tency. sible! error
96 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
97 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
98 NCB: Fatal error during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
99 NCS: Invalid message. Internal software error. No error recovery pos- Serious system System Restart
sible! error
100 NCS: Invalid GroupId. Internal software error. No error recovery pos- Serious system System Restart
sible! error
101 NCS: No group for server Internal software error. No error recovery pos- Serious system System Restart
on CPU. sible! error
102 NCS: No channel for ser- Internal software error. No error recovery pos- Serious system System Restart
ver on CPU. sible! error
103 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
%d. sible! error
104 NCS: Invalid ServerId. Internal software error. No error recovery pos- Serious system System Restart
sible! error

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–7

No Error text Cause Correction Error class Reset mode


105 NCS: Invalid GroupId. Internal software error. No error recovery pos- Serious system System Restart
sible! error
106 NCS: Server unknown. Internal software error. No error recovery pos- Serious system System Restart
sible! error
107 NCS: No channel for ser- Internal software error. No error recovery pos- Serious system System Restart
ver on CPU. sible! error
108 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
to %d
%d. sible! error
109
110 NCS: DEBUG Requests Internal software error. No error recovery pos- Serious system System Restart
exceeded. sible! error
111 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
to %d. sible! error
113
114 NCS: DEBUG Requests Internal software error. No error recovery pos- Serious system System Restart
exceeded. sible! error
115 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
to %d. sible! error
119
120 NCS: Invalid magic num- Internal software error. No error recovery pos- Serious system System Restart
ber. sible! error
121 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
%d. sible! error
122 NCB: No memory during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
123 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
124 NCB: Fatal error during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
125 NCB: No memory during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
126 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
127 NCS: Default server not Internal software error. No error recovery pos- Serious system System Restart
installed. sible! error
128 NCS: Client signed on. The client is announced Remove the second call Serious system System Restart
to the NCS and calls of Ncs_Open in the ap- error
NCS_Open again. plication.
129 NCS: No memory. Internal software error. No error recovery pos- Serious system System Restart
sible! error
130 NCS: Invalid mode. Internal software error. No error recovery pos- Serious system System Restart
sible! error
131 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
%d. sible! error
132 NCS: No tokens. Internal software error. No error recovery pos- Serious system System Restart
sible! error
133 NCS: No mailbox. No valid mailbox id pa- Give the lent mailbox to Serious system System Restart
rameter while call the client before call of error
Ncs_Open with mailbox Ncs-Open and then call it
lend mode. The client with the valid mailbox.
must ask the task, who
lend the mailbox, to get
the mailbox id.

1070 073 799-102 (02.05) GB


3–8 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


134 NCS: Client not signed The client is not an- The application must be Serious system System Restart
on. nounced to the NCS, but announced to the NCS by error
try to use NCS-Services. calling Ncs_Open before
using Ncs-Services.
135 NCS: Default server not Internal software error. No error recovery pos- Serious system System Restart
installed. sible! error
136 NCS: Server calls Internal software error. No error recovery pos- Serious system System Restart
Ncs_Close. sible! error
137 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
%d. sible! error
138 NCS: No tokens. Internal software error. No error recovery pos- Serious system System Restart
sible! error
139 NCS: Client not signed The client is not an- The application must be Serious system System Restart
on. nounced to the NCS, but announced to the NCS by error
try to use NCS-Services. calling Ncs_Open before
using Ncs-Services.
140 NCS: Mailbox on loan. Internal software error. No error recovery pos- Serious system System Restart
sible! error
141 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
to %d. sible! error
142
143 NCS: Invalid message. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
144
145 NCS: Invalid ServerId. Internal software error. No error recovery pos- Serious system System Restart
sible! error
146 NCB: No tokens during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
147 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
148 NCB: Fatal error during Internal software error. No error recovery pos- Serious system System Restart
NCB startup. sible! error
149 NCB: PXROS error %d Internal software error. No error recovery pos- Serious system System Restart
during NCB startup. sible! error
150 NCS: Default server not Internal software error. No error recovery pos- Serious system System Restart
installed. sible! error
151 NCS: Client not signed The client is not an- The application must be Serious system System Restart
on. nounced to the NCS, but announced to the NCS by error
try to use NCS-Services. calling Ncs_Open before
using Ncs-Services.
152 NCS: Fatal PXROS error Internal software error. No error recovery pos- Serious system System Restart
%d. sible! error
153 NCS: Invalid ServiceNo. Internal software error. No error recovery pos- Serious system System Restart
sible! error
154 NCS: Invalid ServerId. Internal software error. No error recovery pos- Serious system System Restart
sible! error
155 NCS: Invalid magic num- Internal software error. No error recovery pos- Serious system System Restart
ber. sible! error
156 Task %s cannot be Internal software error. No error recovery pos- Serious system System Restart
installed more than once. sible! error
157 Stack length of idle task Internal software error. No error recovery pos- Serious system System Restart
not TID-pagesize-aligned. sible! error

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–9

No Error text Cause Correction Error class Reset mode


158 Begin of stack could not Internal software error. No error recovery pos- Serious system System Restart
to be written into task table sible! error
159 for %s.
160 Illegal stack size for task Internal software error. No error recovery pos- Serious system System Restart
%s. sible! error
161 Unknown task parameter Internal software error. No error recovery pos- Minor system System Restart
%d for task %s. sible! error
163 No F-word specified for While G93 is active no Please program the com- Part program in the Info dia-
block runtime! movement time is pro- manded movement time warning log with softkey
grammed. Therefore no together with G93 with ”Delete warn-
feedrate can be calcu- address F. ings”
lated.
164 No F-word specified for While G94 is active no Please program the com- Part program in the Info dia-
feedrate! feedrate has been pro- manded feedrate together warning log with softkey
grammed. Therefore no with address F. ”Delete warn-
movement is possible. ings”
165 No F-word specified for While G95 is active no Please program the com- Part program in the Info dia-
feed per revolution! feedrate per revolution manded feedrate together warning log with softkey
has been programmed. with address F. ”Delete warn-
Therefore no movement ings”
can be executed.
166 Database-server task Internal software error. No error recovery pos- Serious system System Restart
cannot be created. sible! error
169 Error %d during transmis- Internal software error. No error recovery pos- Serious system System Restart
sion of database re- sible! error
sponse.
170 Database response ex- Internal software error. No error recovery pos- Serious system System Restart
ceeds maximum size. sible! error
172 Error %d during transmis- Internal software error. No error recovery pos- Serious system System Restart
sion of database re- sible! error
sponse.
173 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
curred during startup. sible! error
174 Error %d during transmis- Internal software error. No error recovery pos- Serious system System Restart
sion of database re- sible! error
sponse.
175 Error %d during transmis- Internal software error. No error recovery pos- Serious system System Restart
sion of database re- sible! error
sponse.
176 Database response ex- Internal software error. No error recovery pos- Serious system System Restart
ceeds maximum size. sible! error
177 Error %d during transmis- Internal software error. No error recovery pos- Serious system System Restart
to sion of database re- sible! error
183 sponse.
184 Invalid plane: Selection The NC function G20 (2 Please program G20 to- Part program Reset of current
with more than 2 axis ad- from 8 axes) has been gether with the two axes error channel
dresses! programmed together which will build up the de-
with more than 2 axes. A sired working plane.
working plane will always
be built up with 2 axes.
185 Error %d during transmis- Internal software error. No error recovery pos- Serious system System Restart
to sion of database re- sible! error
187 sponse.

1070 073 799-102 (02.05) GB


3–10 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


188 Error %d with synchro- Internal software error. No error recovery pos- Serious system System Restart
to nisation of the database sible! error
191 server tasks.
192 It was not possible to Internal software error. No error recovery pos- Serious system System Restart
create UserStruct to work sible! error
with file system.
193 Unknown job has been Internal software error. No error recovery pos- Serious system System Restart
received. sible! error
194 Error %d with synchro- Internal software error. No error recovery pos- Serious system System Restart
nisation of the database sible! error
server tasks.
195 It was not possible to Internal software error. No error recovery pos- Serious system System Restart
create UserStruct to work sible! error
with file system.
196 Unknown job has been Internal software error. No error recovery pos- Serious system System Restart
received. sible! error
197 Error with reception of a Internal software error. No error recovery pos- Serious system System Restart
job ( %d ). sible! error
198 Error %d with synchro- Internal software error. No error recovery pos- Serious system System Restart
nisation of the database sible! error
server tasks.
199 It was not possible to Internal software error. No error recovery pos- Serious system System Restart
create UserStruct to work sible! error
with file system.
200 Unknown job has been Internal software error. No error recovery pos- Serious system System Restart
received. sible! error
201 Error %d with synchro- Internal software error. No error recovery pos- Serious system System Restart
nisation of the database sible! error
server tasks.
202 Signing on with the NCS Internal software error. No error recovery pos- Serious system System Restart
failed with %d. sible! error
203 It was not possible to Internal software error. No error recovery pos- Serious system System Restart
create UserStruct to work sible! error
with file system.
204 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
to curred during startup. sible! error
207
208 Database-server task Internal software error. No error recovery pos- Serious system System Restart
to cannot be created. sible! error
210
211 Unknown job has been Internal software error. No error recovery pos- Serious system System Restart
received. sible! error
212 Error with reception of a Internal software error. No error recovery pos- Serious system System Restart
job ( %d ). sible! error
213 Error %d occurred with Internal software error. No error recovery pos- Serious system System Restart
definition of services. sible! error
214 Serious system error of Internal software error. No error recovery pos- Serious system System Restart
database %d %d %d %d sible! error
%x %d.
215 Fileserver function sig- Internal software error. No error recovery pos- Serious system System Restart
to nals error %d of function sible! error
218 unit %d.
219 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
curred during startup. sible! error

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–11

No Error text Cause Correction Error class Reset mode


220 Fileserver function sig- Internal software error. No error recovery pos- Serious system System Restart
nals error %d of function sible! error
unit %d.
221 Temporary files not de- Internal software error. No error recovery pos- Core system in the Info dia-
to leted due to error %d of sible! warning log with softkey
222 function unit %d. ”Delete warn-
ings”
223 Unknown job has been Internal software error. No error recovery pos- Serious system System Restart
to received. sible! error
224
225 Error %d with synchro- Internal software error. No error recovery pos- Serious system System Restart
nisation of the database sible! error
server tasks.
226 Error with return of re- Internal software error. No error recovery pos- Serious system System Restart
sources ( %d ). sible! error
227 Error with reception of a Internal software error. No error recovery pos- Serious system System Restart
to job ( %d ). sible! error
228
229 Fileserver function sig- Internal software error. No error recovery pos- Serious system System Restart
to nals error %d of function sible! error
231 unit %d.
232 Error with return of re- Internal software error. No error recovery pos- Serious system System Restart
to sources ( %d ). sible! error
235
235 Error with return of re- Internal software error. No error recovery pos- Serious system System Restart
sources ( %d ). sible! error
236 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
curred when opening sible! error
tables for %s.
237 Axis address outside An axis outside the work- Delete all axes outside Part program Reset of current
plane of circle! ing plane has been pro- the activated working error channel
grammed while circular plane or switch on helical
interpolation is active. interpolation (G2,G3), re-
spectively helical N inter-
polation (G202, G203).
238 Invalid endpoint; no tan- The programmed end Please check the pro- Part program Reset of current
gential arc possible! point coordinate lies in grammed coordinates of error channel
the direction of the end the previous NC block
tangent of the previous and adjust them if neces-
NC block. A circle with a sary.
tangential transition can-
not be calculated.
239 Function Pxr_GetTidProt- Internal software error. No error recovery pos- Minor system System Restart
Mem returns with error sible! error
number %d.
240 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
curred when opening sible! error
tables for %s.
241 Function Pxr_FreeTid- At the attempt to get me- No error recovery pos- Minor system System Restart
ProtMem return with error mory for the error texts a sible! error
number %d. fault has occurred.
242 Text file too short or cor- At the attempt to transfer No error recovery pos- Minor system System Restart
rupted (line %d). the error text file to the er- sible! error
ror buffer a fault has oc-
curred.

1070 073 799-102 (02.05) GB


3–12 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


244 Invalid size %d of input Internal software error. No error recovery pos- Serious system System Restart
text of WEA-class %d sible! error
configured.
245 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
curred during closing of sible! error
tables for %s.
246 Data module %d not Call of an APS module Load the corresponding PLC error Restart of PLC
loaded. with parameter transfer in data module or transfer program
a data module: The trans- the right data number mo-
ferred data module is not dule during the subrou-
loaded in PLC program. tine call.
247 The parameter P0 of Address of parameter Modify the PLC user pro- PLC error Restart of PLC
APS-module field can’t be determined gram at the position program
0x%3x????? is incorrect because the transfer pa- where the APS module is
rameter is wrong. called.
248 MSD file for configured The MSD file for the se- Copy the MSD file for the Core system in the Info dia-
language not found. lected language is miss- selected language to the warning log with softkey
ing. The name of this file root directory or user FE- ”Delete warn-
is composed by ’mza- PROM. If it is not pres- ings”
texte’ followed by a lan- ent, request the missing
guage-specific extension file from your machine
(e.g. ”.044” for English). tool builder.
249 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
curred during closing of sible! error
tables for %s.
253 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
to curred during initialization sible! error
254 of tables for %s.
256 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
curred during closing of sible! error
tables for %s.
258 Database error %d with Internal software error. No error recovery pos- Serious system System Restart
release of reserved block sible! error
for error %d.
259 Database error %d oc- Internal software error. No error recovery pos- Serious system System Restart
curred during closing of sible! error
tables for %s.
260 Unknown error number Internal software error. No error recovery pos- Minor system System Restart
%d reported. sible! error
261 No feedrate defined for The declared axis has no Please define the velocity Core system in the Info dia-
axis %d in MACODA. rapid traverse velocity de- limits of the axis in MA- warning log with softkey
fined in MACODA. There- CODA under the group ”Delete warn-
for the axis cannot be velocity. ings”
moved.
262 Machine error class not Internal software error. No error recovery pos- Minor system System Restart
admissible for error num- sible! error
ber %d.
263 Message transmitted with Internal software error. No error recovery pos- Minor system System Restart
incorrect class %d sible! error
(passed on to class %d).
264 Invalid class for error %d Internal software error. No error recovery pos- Minor system System Restart
in development database. sible! error
266 Database error %d during Internal software error. No error recovery pos- Minor system System Restart
processing of tables for sible! error
%s.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–13

No Error text Cause Correction Error class Reset mode


267 Systeminfo %d of class Internal software error. No error recovery pos- Minor system System Restart
%d could not be written sible! error
into database.
268 Database error %d with Internal software error. No error recovery pos- Serious system System Restart
to release of reserved block sible! error
269 for error %d.
270 Invalid size %d of input Internal software error. No error recovery pos- Minor system System Restart
text of WEA-class %d sible! error
configured.
273 Database error %d during Internal software error. No error recovery pos- Minor system System Restart
processing of tables for sible! error
%s.
274 Error %d from the NCB Internal software error. No error recovery pos- Serious system System Restart
transport level occurred in sible! error
WERA.
275 System information re- Internal software error. No error recovery pos- Minor system System Restart
to quest from invalid class sible! error
276 0x%x (bit coded).
277 System information re- Internal software error. No error recovery pos- Minor system System Restart
quest with invalid version sible! error
%d.
278 System information re- Internal software error. No error recovery pos- Minor system System Restart
quest with incorrect sible! error
WERA client number %d.
279 System information re- Internal software error. No error recovery pos- Minor system System Restart
quest with illegal search sible! error
strategy %d.
280 Database error %d during Internal software error. No error recovery pos- Minor system System Restart
to processing of tables for sible! error
287 %s.
288 System information re- Internal software error. No error recovery pos- Minor system System Restart
quest with illegal selector sible! error
%d.
291 Database error %d during Internal software error. No error recovery pos- Minor system System Restart
to processing of tables for sible! error
292 %s.
293 Database error %d with Internal software error. No error recovery pos- Serious system System Restart
release of reserved block sible! error
for error %d.
294 Database error %d during Internal software error. No error recovery pos- Minor system System Restart
to processing of tables for sible! error
296 %s.
297 Error %d from the NCB Internal software error. No error recovery pos- Serious system System Restart
transport level occurred in sible! error
WERA.
298 Invalid WERA client num- Internal software error. No error recovery pos- Minor system System Restart
ber %d was specified sible! error
when logging off.
299 Database error %d during Internal software error. No error recovery pos- Minor system System Restart
processing of tables for sible! error
%s.
300 Database error %d with Internal software error. No error recovery pos- Serious system System Restart
release of reserved block sible! error
for error %d.

1070 073 799-102 (02.05) GB


3–14 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


301 Database error %d during Internal software error. No error recovery pos- Minor system System Restart
to processing of tables for sible! error
302 %s.
303 Database error %d with Internal software error. No error recovery pos- Serious system System Restart
release of reserved block sible! error
for error %d.
305 Database error %d with Internal software error. No error recovery pos- Serious system System Restart
release of reserved block sible! error
for error %d.
308 Memory for permanent Internal software error. No error recovery pos- Serious system System Restart
logbook too small by %d sible! error
bytes.
309 Request from permanent Internal software error. No error recovery pos- Minor system System Restart
logbook with invalid class sible! error
%d (bit coded).
312 Unconfigured working Internal software error. No error recovery pos- Part program Reset of current
plane selected! sible! error channel
313 Control data contains un- Internal software error. No error recovery pos- Part program Reset of current
to defined status! sible! error channel
314
315 Different scale factors for For circle interpolation Please check the scaling Part program Reset of current
to circular blocks! both axes performing the factor programmed to- error channel
316 circle must possess the gether with G38.
same scaling factor.
318 Plane transformation with While the G38 coordinate Switch coordinate rotation Part program Reset of current
angle No error recovery rotation is active the before the plane switch if error channel
possible!! working plane must not necessary by program-
be changed. The pro- ming G39.
grammed coordinate rota-
tion always refers to the
active working plane.
319 Control data contains un- Internal software error. No error recovery pos- Part program Reset of current
defined status! sible! error channel
321 Programmed radius value The distance between Please check the pro- Part program Reset of current
too small! startpoint and endpoint grammed radius and the error channel
coordinates is longer than coordinates of start- and
2 times circle radius. The endpoint.
data is not consistent for
calculation of a circle.
322 Incorrect interpolation pa- An interpolation parame- Please check the pro- Part program Reset of current
rameter for current circle ter (I,J,K) has been pro- grammed interpolation error channel
plane! grammed which refers to parameters and the acti-
an axis outside the active vated working plane.
working plane. Working plane and inter-
polation parameters are
directly switched together.
323 Invalid center pro- The difference between Please check the pro- Part program Reset of current
grammed! the distance startpoint to grammed coordinates for error channel
center point and the dis- startpoint, endpoint and
tance endpoint to center center point. If necessary
point deviates from the change the tolerance
tolerance configured in value in MACODA.
MACODA.
324 There has been a change The working plane must Please correct the part Part program Reset of current
in plane before a circular not be switched in NC program. error channel
block with tangential block before G5.
entry!

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–15

No Error text Cause Correction Error class Reset mode


325 Preceding linear block Linear block before G5 Please correct the part Part program Reset of current
does not lie in the circle has axes parts outside of program. error channel
plane! active plane.
326 Block preceding circular For calculating the tan- Please correct the part Part program Reset of current
block does not contain a gent the block before G5 program. error channel
traversing movement! needs axes motion.
328 Data from modified zero An error occurred while Please check if the re- Part program Reset of current
offset table not read. reading a zero offset quired zero offset table error channel
table. exists and is attached to
the correct channel.
329 There is no zero offset Although a zero offset Please activate the re- Part program Reset of current
table active! function is programmed, quired zero offset table by error channel
no zero offset table has programming G22 V... .
been activated.
333 Undefined mask! Internal software error. No error recovery pos- Part program Reset of current
to sible! error channel
336
337 Undefined plane! Internal software error. No error recovery pos- Part program Reset of current
to sible! error channel
341
342 Axis number too high! Programming error: Func- No error recovery pos- Part program Reset of current
tion Acb_CopyAbsCoordi- sible! error channel
nateToStore called for an
invalid axis no.
349 Endpoint coordinate for An axis must be pro- Please use either abso- Part program Reset of current
to %s-axis ambiguous! grammed either absolute lute or incremental pro- error channel
351 or incremental. Both pro-
p gramming
g g mode for on
gramming modes to- axis.
gether in one NC block
are not allowed.
359 Invalid correction index in An invalid index for tool Please program a correc- Part program Reset of current
part program! length correction has tion index between 1 and error channel
been programmed. Valid 48.
Values: [1..48]
360 No geometry correction A tool length correction Please activate a geome- Part program Reset of current
table active! function has been pro- try correction table by error channel
grammed although no ge- programming G22 K ... .
ometry correction table
has been activated.
366 Error in geometry correc- The required geometry Please check if the de- Part program Reset of current
tion data! correction table cannot be manded geometry correc- error channel
opened. tion table exists.
367 Incorrect function for tool The cutter compensation Please activate a geome- Part program Reset of current
length compensation! function has been acti- try correction table by error channel
vated, although no geom- programming G22 K ... .
etry correction table has
been activated.
370 Address F for dwell miss- Dwell time with G4 is pro- Insert address F with time Part program Reset of current
ing. grammed. The address F in seconds in the NC- error channel
with time in seconds is block.
missing.

1070 073 799-102 (02.05) GB


3–16 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


371 Recording error with data Internal software error: After reducing the velocity Minor system Reset of current
loss Because of a big load or modifying the part pro- error channel
(e.g. a part program with gram you should restart
short blocs) the Axis Os- the recording.
cilloscope (Contour Dis-
play) is not able to store
the recorded data.
372 Illegal trigger occurred Internal software error. Please note the adjusted Minor system Reset of current
trigger settings in Axis error channel
Oscilloscope (Contour
Display) It is possible to
store the adjusted trigger
settings with ”Save set-
tings” in a file. The ad-
justed trigger settings to-
gether with the detailed
software version should
be sent to the after sales
service of the NC
manufacturer. No more
steps are necessary.
373 Drive communication dis- See also operator’s Stop part program, which Minor system Reset of current
rupted manual. Parallel access is using the service chan- error channel
to the service channel nel. Push softkey ”Read-
during recording of the ing drive’s data” to read
drive oscilloscope or drive data again.
reading data from drive
to control.
374 Management of drive re- Internal software error. No error recovery pos- Minor system Reset of current
cording file incorrect sible! error channel
375 Invalid recording parame- Internal software error. No error recovery pos- Minor system Reset of current
ter sible! error channel
376 Recording file not found Internal software error. No error recovery pos- Minor system Reset of current
sible! error channel
377 Evaluation of recording Internal software error. No error recovery pos- Minor system Reset of current
file faulty sible! error channel
378 Recording terminated ab- Internal software error. No error recovery pos- Minor system Reset of current
normally sible! error channel
379 Error in axis diagnostics Internal software error. No error recovery pos- Serious system System Restart
configuration sible! error
380 Error in axis diagnostics Internal software error. No error recovery pos- Serious system System Restart
configuration sible! error
381 Database error %d during Internal software error. No error recovery pos- Minor system System Restart
to processing of tables for sible! error
382 %s.
383 Database read error for Internal software error. No error recovery pos- Minor system System Restart
MACODA parameter %d. sible! error
387 Syntax error with ”%s” The programmed syntax Change the part program Part program Reset of current
in a NC-block is not al- at the indicated point. error channel
lowed.
388 No storage available for Programming error at Correct programming er- Part program Reset of current
link table %s CPL - command. Further ror. Select part program warning channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–17

No Error text Cause Correction Error class Reset mode


389 Function PxMcTakeBlk When creating block con- It is necessary to make Serious system System Restart
to returns with error number trol internal memory is more memory available error
390 %d needed. But there is no for the system for exam-
more memory available. ple by decreasing the
number of channels (MA-
CODA block no.
904000001) or decreas-
ing the number of blocks
in thee preparation
p epa a o (MA-
(
CODA block no.
7060000110) or decreas-
ing the memory area for
CPL programs (MACODA
block no. 707000010).
The available free me-
mory is indicated under
Diagnosis->Control->Me-
mory->Memory 2.
391 Cannot install block proc- Internal software error. No error recovery pos- Serious system System Restart
essing management! sible! error
393 NC-Configuration: NC- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
Job ”%s” is missing in file. indicated lisp file. error channel
configured joblist
395 Invalid file name occurred Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
397 Type of result not equal to Programming error at Correct programming er- Part program Reset of current
type of CPL - expression CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
398 Link table not available Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
399 Error with RESET proc- Internal software error. No error recovery pos- Serious system System Restart
essing: database was not sible! error
closed ( %d )
400 Internal PLC system er- An internal critical system No error recovery pos- Serious system System Restart
ror: 0x%x 0x%x error occurred. sible! error
401 Hardware error: %d %d Checked hardware sends No error recovery pos- Serious system System Restart
an error. sible! error
402 CAN defective! Error message of the No error recovery pos- Serious system System Restart
can-bus. sible! error
403 Abort during direct ac- There is no time check at No error recovery pos- PLC error Restart of PLC
cess a directly access to I/O. sible! program
404 Cycle time-out There is a timeout of the This error occurs often by PLC error Restart of PLC
to PLC program programming loops or re- program
406 cursive calls of program
modules. If the max.
cycle time is defined at
the module OM2, this
value can be adjusted.
407 Illegal write access! The addresses of some Check and modify the PLC error Restart of PLC
write statements are PLC program. program
checked.

1070 073 799-102 (02.05) GB


3–18 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


408 Nesting depth exceeded! There are to many nested This is an error at the PLC error Restart of PLC
program calls. PLC program, often program
caused by recursive pro-
gram calls.
409 User stack overflow %x! There are to many It is an error at the PLC PLC error Restart of PLC
PUSH-statements. The program, often caused by program
maximum number is 256. recursive program calls.
Reduce the number of
push-statements.
410 User stack underflow! The number of POP- Check and modify the PLC error Restart of PLC
statements exceeds the PLC program. program
number of PUSH-state-
ments.
411 No data module active! An access to a data mo- Activate the data module PLC error Restart of PLC
dule occurred, but is no before you access data of program
data module active. it.
412 Illegal command found! Illegal Opcode occurred. The program storage has PLC error Restart of PLC
been overwritten at run- program
time.
413 Parameter error! There is an access to a Check and modify the PLC error Restart of PLC
not existing parameter of PLC program. program
a program module or the
illegal use of it.
414 Invalid operand address! The address of a read/ It is an error at the PLC PLC error Restart of PLC
write-access exceeds the program often caused by program
defined area of the oper- an indirect access or by
and. access to a data module
which is defined to short.
415 Illegal write access! The address of a read/ Check and modify the PLC error Restart of PLC
write-access exceeds the PLC program. program
defined area of the oper-
and.
416 Unknown module called! The called module Check and modify the plc PLC error Restart of PLC
doesn‘t exist. This is often program. program
caused by incremental
download of program
modules or by indirect ac-
cess to operands.
417 HLT - command found! A programmed HLT-state- – PLC error Restart of PLC
ment occurred. program
422 User error message: %d The PLC program is – PLC error Restart of PLC
%d %d stopped by a pro- program
grammed error of a hll-
program module.
423 User warning: %d %d %d A Warning occurred – PLC error Restart of PLC
caused by a programmed program
warning of a hll-program
module. PLC doesn’t
stop.
424 Recursive C-module call A hll-program module Check and modify the PLC error Restart of PLC
mustn’t be called recur- PLC program. program
sively.
425 Configuration list conflict! The real I/O-configuration Check the real I/O-config- PLC error Restart of PLC
differs to I/O-configuration uration and the I/O-con- program
list defined at DW33 of figuration defined at
OM2. DW33 of OM2.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–19

No Error text Cause Correction Error class Reset mode


428 Error in definition of per- Programming error at Correct programming er- Minor system System Restart
manent variables in line CPL - command. Further ror. Select part program error
”%d” of ”%s” information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
429 General linker/CPL error Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
430 Channel-specific system Internal software error. No error recovery pos- Minor system System Restart
info from class %d with sible! error
invalid channel %d
431 Invalid file name occurred Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
432 No PLC user program There is no PLC program Copy the PLC program to PLC error Restart of PLC
found to load at the userfep-di- the userfep-directory and program
rectory. restart the system.
Another way to get load
the PLC program is to
load it by the program-
ming device and then
save it to the userfep-di-
rectory.
433 PLC user program loaded There is no PLC program If you want to load the PLC error Restart of PLC
from internal at the PCMCIA-card and PLC program of the program
FEPROM, since not on so the PLC program of PCMCIA-card, put the
Mem card the userfep-directory is right one into the slot and
loaded. restart the system again.
435 Software limit range ex- An axis coordinate has Check the programmed Part program Reset of current
to ceeded in axis %d! been programmed which axis coordinates, or, nec- error channel
438 violates the software essary change the soft-
travel limits defined in ware travel limits in
MACODA. MACODA.
439 Software limit range ex- An axis coordinate has Check the programmed Part program Reset of current
to ceeded in rotary axis! been programmed which axis coordinates, or, nec- error channel
442 violates the software essary change the soft-
travel limits defined in ware travel limits in
MACODA. MACODA.
445 File %s in use Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
446 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
number of parameters CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
447 Invalid permanent vari- Programming error at Correct programming er- Part program Reset of current
able %s CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
448 Type of variable ”%s” in- Programming error at Correct programming er- Part program Reset of current
valid. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–20 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


449 Incorrect field index at Programming error at Correct programming er- Part program Reset of current
%s. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
450 Multiple subprogram pro- Programming error at Correct programming er- Part program Reset of current
hibited CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
453 Insufficient memory for Too small a value for link Enlarge the data range Part program Reset of current
to program %s table defined in MACODA for link table in MACODA error channel
456 block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.
457 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
type of parameter CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
458 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
459 Variable type incorrect Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
460 Invalid variable Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
461 Variable type incorrect Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
462 Invalid variable Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
463 Insufficient memory for Too small a value for link Enlarge the data range Part program Reset of current
program %s table defined in MACODA for link table in MACODA error channel
block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.
464 Too many variables in Too small a value for link Enlarge the data range Part program Reset of current
program %s table defined in MACODA for link table in MACODA error channel
block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.
465 Insufficient memory for Too small a value for link Enlarge the data range Part program Reset of current
program %s table defined in MACODA for link table in MACODA error channel
block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.
466 Too many variables in Too small a value for link Enlarge the data range Part program Reset of current
program %s table defined in MACODA for link table in MACODA error channel
block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–21

No Error text Cause Correction Error class Reset mode


468 Insufficient memory for Too small a value for link Enlarge the data range Part program Reset of current
program %s table defined in MACODA for link table in MACODA error channel
block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.
469 %s-command only in Programming error at Correct programming er- Part program Reset of current
DLG - ENDDLG possible CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
470 Insufficient memory for Too small a value for link Enlarge the data range Part program Reset of current
program %s table defined in MACODA for link table in MACODA error channel
block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.
471 CPL-channel number is Internal software error. No error recovery pos- Part program Reset of current
invalid sible! error channel
472 Invalid permanent vari- Programming error at Correct programming er- Part program Reset of current
able %s CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
473 Type of variable ”%s” in- Programming error at Correct programming er- Part program Reset of current
valid. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
474 Not enough memory in Internal software error. No error recovery pos- Part program Reset of current
CPL-Server sible! error channel
475 Invalid CPL-ID. Internal software error. No error recovery pos- Part program Reset of current
sible! error channel
476 Container is full. Internal software error. No error recovery pos- Part program Reset of current
sible! error channel
477 Container-error. Internal software error. No error recovery pos- Part program Reset of current
sible! error channel
478 Error in NCS-Basic-Com- Internal software error. No error recovery pos- Part program Reset of current
munication. sible! error channel
479 Invalid line or column in Programming error at Correct programming er- Part program Reset of current
CPL-command. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
480 Invalid parameter Programming error at Correct programming er er- Part program Reset of current
to CPL - command. Further ror. Select p
part p
program
g error channel
483 information in ”CPL
C Pro- again and start it again if
gramming
i Instructions”.
I t ti ” necessary.
484 Invalid parameter value Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
485 Invalid file number Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
486 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–22 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


487 Parameter missing Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
488 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command.
command Further ror Select part program
ror. error channel
490 information in ”CPL
CPL Pro- again and start it again if
gramming Instructions”. necessary.
491 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to
o CPL - co
C command.
a d Further
e ror.
o SeSelect part p
ec pa program
og a error
e o cchannel
a e
492 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
493 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
494 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
495 Invalid component length Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
496 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
497 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
498 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
499 File length must be inte- Programming error at Correct programming er- Part program Reset of current
ger CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
500 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
501 Parameter missing Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
502 Invalid filename Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
503 Maximum CPL-string Programming error at Correct programming er- Part program Reset of current
length exceeded. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–23

No Error text Cause Correction Error class Reset mode


504 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
505 Invalid file number Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
506 Invalid format. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
507 Invalid file number Programming error at Correct programming er- Part program Reset of current
to
o CPL - co
C command.
a d Further
e ror.
o SeSelect part p
ec pa program
og a error
e o cchannel
a e
508 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
509 INPUT format incorrect Programming error at Correct programming er er- Part program Reset of current
to CPL - command. Further ror. Select p
part p
program
g error channel
512 information in ”CPL
C Pro- again and start it again if
gramming
i Instructions”.
I t ti ” necessary.
513 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
514 Invalid file number Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
515 PRN-command is miss- Programming error at Correct programming er- Part program Reset of current
ing. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
516 Invalid file number Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
517 No memory for CPL-dia- Internal software error. No error recovery pos- Part program Reset of current
log-commands reserved. sible! error channel
518 PRN format incorrect Programming error at Correct programming er er- Part program Reset of current
to CPL - command. Further ror. Select p
part p
program
g error channel
521 information in ”CPL
C Pro- again and start it again if
gramming
i Instructions”.
I t ti ” necessary.
522 Unknown CPL-command. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
523 Permanent CPL variable Programming error at Correct programming er- Minor system System Restart
”%s” not installed. Me- CPL - command. Further ror. Select part program error
mory full. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
524 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–24 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


525 Error in expression %s Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
526 Invalid filename Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
527 %s missing. Programming error at Correct programming er- Part program Reset of current
to
o CPL - co
C command.
a d Further
e ror.
o SeSelect part p
ec pa program
og a error
e o cchannel
a e
528 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
529 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
530 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
531 Invalid file number Programming error at Correct programming er- Part program Reset of current
to
o CPL - co
C command.
a d Further
e ror.
o SeSelect part p
ec pa program
og a error
e o cchannel
a e
532 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
533 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
534 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
535 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
536 Invalid file number Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
537 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
538 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
539 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
540 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
541 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
542 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–25

No Error text Cause Correction Error class Reset mode


543 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
544 Invalid file number Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
545 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
546 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
547 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
548 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
549 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
550 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
551 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
552 Invalid file number Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
553 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
554 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
555 Invalid component Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
556 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
557 Invalid component Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
558 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
559 Invalid file number Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
560 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–26 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


561 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
562 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
563 Invalid component Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
564 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
565 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
566 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
567 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
568 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
569 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
570 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
571 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
572 Invalid file number Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
573 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
574 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
575 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
576 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
577 Invalid file number Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
578 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
579 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
580 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
581 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
582 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–27

No Error text Cause Correction Error class Reset mode


583 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
584 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
586 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
587 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
588 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
589 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
590 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
591 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
592 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
593 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
594 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
596 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
597 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
598 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
599 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
600 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
601 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
602 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
604 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–28 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


605 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
606 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
607 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
608 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
609 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
610 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
611 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
612 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
613 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
614 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
615 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
616 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
617 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
618 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
619 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
620 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
621 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
622 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
623 Invalid field index Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
624 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–29

No Error text Cause Correction Error class Reset mode


625 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
627 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
628 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
629 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
630 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
631 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
632 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
633 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
634 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
635 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
636 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
637 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
640 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
641 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
642 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
643 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
645 string constant too long Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
648 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
649 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
650 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–30 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


651 Option inactive Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
653 Invalid permanent vari- Programming error at Correct programming er- Part program Reset of current
able %s CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
655 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
656 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
657 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
658 Type must be integer. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
659 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
660 Error on reading MA- Programming error at Correct programming er- Part program Reset of current
CODA parameter. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
661 Integer-overflow, value Programming error at Correct programming er- Part program Reset of current
becomes negative CPL - command. Further ror. Select part program warning channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
662 CPL-Dialog No error re- Programming error at Correct programming er- Part program Reset of current
covery possible! CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
663 invalid Variable %s Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
664 Invalid permanent vari- Programming error at Correct programming er- Part program Reset of current
able %s CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
665 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
666 Type must be BIT Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
667 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–31

No Error text Cause Correction Error class Reset mode


668 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
669 Invalid expression Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
670 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
671 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
674 Invalid expression information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
675 Hyphen not permitted Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
676 Invalid format. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program warning channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
677 PRN format incorrect. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program warning channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
678 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
679 Invalid parameter Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
681 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
682 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
683 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
684 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
685 Invalid expression Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
686 Subprogram %s does not Programming error at Correct programming er- Part program Reset of current
exist CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–32 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


687 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
688 Invalid expression Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
689 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
692 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
693 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
694 Type must be BIT Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
695 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
696 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
697 Type must be BIT Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
698 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
699 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
700 Type must be BIT Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
701 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
704 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
705 Invalid variable Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
706 Invalid field limit Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
709 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
710 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
711 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
712 Invalid variable Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
713 Invalid field type information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–33

No Error text Cause Correction Error class Reset mode


714 Incorrect branch destina- Programming error at Correct programming er- Part program Reset of current
tion CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
715 Option inactive Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
716 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
717 Invalid variable Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
718 Invalid statement Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
719 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
722 Invalid statement Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
723 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
724 Invalid statement Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
725 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
726 Invalid statement Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
727 DSP format incorrect Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
728 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
729 Invalid statement Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
730 DSP format incorrect Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program warning channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–34 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


731 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
732 Invalid expression Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
733 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
734 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
735 Error writing in file %s Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
736 Incorrect branch destina- Programming error at Correct programming er- Part program Reset of current
tion CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
737 Axis not exist Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
738 Axis position could not be Programming error at Correct programming er- Part program Reset of current
read CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
739 there is no free CPL-Dia- CPL-Dialog is used by a Exit part program that Part program Reset of current
log-Window part program from uses CPL-Dialog. error channel
another channel.
741 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
742 type of Machine Parame- Programming error at Correct programming er- Part program Reset of current
ter and type of variable CPL - command. Further ror. Select part program error channel
incompatible information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
743 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
type of parameter CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
744 invalid axis number in Programming error at Correct programming er- Part program Reset of current
%s-command CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
745 invalid ident number in Programming error at Correct programming er- Part program Reset of current
%s-command CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
747 Variable %s not used. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–35

No Error text Cause Correction Error class Reset mode


748 Nesting too deep Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
749 Block not found Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
750 Line not found Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
751 Label %s not found Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
752 Invalid operand Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
755 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
756 Invalid comparison Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
757 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
758 Invalid assignment Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
760 Axis not exist Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
761 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
762 Error in expression %s Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
763 Character area %s not Programming error at Correct programming er- Part program Reset of current
to used CPL - command. Further ror. Select part program error channel
764 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
765 %s missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
766 Invalid statement Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
767 Invalid parameter Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–36 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


768 Error in accessing tool Programming error at Correct programming er- Part program Reset of current
to table CPL - command. Further ror. Select part program error channel
769 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
770 TDA-command with in- Programming error at Correct programming er- Part program Reset of current
valid table number CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
771 TDA-command with in- Programming error at Correct programming er- Part program Reset of current
valid field number CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
772 TDA-command with in- Programming error at Correct programming er- Part program Reset of current
valid data type CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
773 Error in accessing tool Programming error at Correct programming er- Part program Reset of current
to table CPL - command. Further ror. Select part program error channel
774 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
775 TDA-command with in- Programming error at Correct programming er- Part program Reset of current
valid table number CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
776 TDA-command with in- Programming error at Correct programming er- Part program Reset of current
valid field number CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
777 TDA-command with in- Programming error at Correct programming er- Part program Reset of current
valid data type CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
778 Nesting too deep. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
779 Invalid parameter value Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
780 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
number of parameters CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
781 Insufficient memory for Too small a value for link Enlarge the data range Part program Reset of current
program %s table defined in MACODA for link table in MACODA error channel
block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.
783 Invalid file name occurred Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
784 Error with reception of in- Internal software error. No error recovery pos- Part program Reset of current
itialization message sible! error channel

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–37

No Error text Cause Correction Error class Reset mode


785 Task %s cannot sign on Internal software error. No error recovery pos- Serious system System Restart
to at the Ncs sible! error
787
788 Invalid type of a job list in- Internal software error. No error recovery pos- Serious system System Restart
terpreter (Jla) sible! error
789 Error with reception of the Internal software error. No error recovery pos- Serious system System Restart
synchronisation message sible! error
from the blkproc. man-
agement
790 SAV: No link table found It was attempted to call a Select program or sub- Part program Reset of current
subprogram, which needs program with option error channel
a link table. It is no link ’CPL-program’.
table available and it
could not be created.
791 SAV: No link table found It is attempted to interpret Select program or sub- Part program Reset of current
a CPL expression, which program with option error channel
needs a link table. This ’CPL-program’.
can occur in manual data
input or after selection of
a DIN program.
792 Error %d with DBVEND in Internal software error. No error recovery pos- Serious system System Restart
control reset handling sible! error
793 Subprogram %s does not Programming error at Correct programming er- Part program Reset of current
exist CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
794 NCB service could not be Internal software error. No error recovery pos- Serious system System Restart
to executed (return value : sible! error
811 %d)
812 Incorrect format during Internal software error. No error recovery pos- Minor system System Restart
signaling of fault/warning sible! error
%d
813 Incorrect format during Internal software error. No error recovery pos- Serious system System Restart
signaling of fault/warning sible! error
%d
814 Error with the packaging Internal software error. No error recovery pos- Minor system System Restart
of the UserStruct of error/ sible! error
warning %d
815 Error with the packaging Internal software error. No error recovery pos- Serious system System Restart
of the UserStruct of error/ sible! error
warning %d
816 Incorrect format during Internal software error. No error recovery pos- Serious system System Restart
signaling of fault/warning sible! error
%d
817 Error with the packaging Internal software error. No error recovery pos- Serious system System Restart
of the UserStruct of error/ sible! error
warning %d
818 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
821 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
822 Invalid statement Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
824 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–38 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


825 Insufficient memory for Too small a value for link Enlarge the data range Part program Reset of current
program %s table defined in MACODA for link table in MACODA error channel
block number 707000010 parameter 707000010
”Data areas for CPL pro- and initiate a new system
grams”. startup.
826 Subprogram %s does not Programming error at Correct programming er- Part program Reset of current
to exist CPL - command. Further ror. Select part program error channel
827 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
828 Insufficient runtime me- Too small a value for Enlarge the data range Part program Reset of current
mory available stack defined in MA- for stack in MACODA pa- error channel
CODA block number rameter 707000010 and
707000010 ”Data areas initiate a new system
for CPL programs”. startup.
830 Invalid size %d of input Internal software error. No error recovery pos- Minor system System Restart
text of class %d sible! error
831 Input text of error %d Internal software error. No error recovery pos- Minor system System Restart
could not be written into sible! error
database
832 %s-axis does not respond Compare SERCOS ad- Servo loop or Reset of all
under SERCOS address dress with corresponding drive fault channels in
%d MACODA data and adjust ”DIAGNOS-
it. TICS” group op-
erating mode
833 %s-axis for switchover in The drive doesn’t accept Read out ident number Servo loop or Reset of all
to SERCOS phase 3 not re- the switching due to miss- S-0-0021 of this axis and drive fault channels in
834 ady –> Check identnum- ing or wrong ident num- correct missing or wrong ”DIAGNOS-
ber S-0-0021. bers. ident number. Initiate a TICS” group op-
new SERCOS startup erating mode
subsequently.
835 Data error in %s (%s- The indicated data record Check data record of the Servo loop or Reset of all
axis). isn’t accepted by the NC and change it if nec- drive fault channels in
drive (address). Possible essary. ”DIAGNOS-
reason: data record in the TICS” group op-
NC has incorrect format, erating mode
the value is beyond the
range allowed by the
drive or the data is write
protected at the moment.
Note the exact error de-
scription.
836 %s-axis for switchover in The drive doesn’t accept Read out ident number Servo loop or Reset of all
SERCOS phase 3 not re- the switching due to miss- S-0-0021 of this axis and drive fault channels in
ady –> Check ident num- ing or wrong ident num- correct missing or wrong ”DIAGNOS-
ber S-0-0021. bers. ident number. Initiate a TICS” group op-
new SERCOS startup erating mode
subsequently.
837 Error when clearing Cannot set SERCOS No error recovery pos- Servo loop or Reset of all
diagn. class 1 error for command reset class1 sible! drive fault channels in
%s-axis ”DIAGNOS-
TICS” group op-
erating mode
838 %s-axis for switchover in The drive doesn’t accept Read out ident number Servo loop or Reset of all
SERCOS phase 4 not re- the switching due to miss- S-0-0022 of this axis and drive fault channels in
ady –> Check ident num- ing or wrong ident num- correct missing or wrong ”DIAGNOS-
ber S-0-0021. ber. ident number. Initiate a TICS” group op-
new SERCOS startup erating mode
subsequently.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–39

No Error text Cause Correction Error class Reset mode


840 Incorrect SERCOS phase Use of a wrong commu- Check the commanded Servo loop or Reset of all
selection (->%d) nication phase in SER- SERCOS communication drive fault channels in
COS startup. The phases phase and change it if ”DIAGNOS-
0 to 4 may be used. The necessary. TICS” group op-
phases must always be erating mode
set in ascending order in
steps of one.
841 Serious SERCOS error A serious error during Check drives, connec- Servo loop or Reset of all
with return into phase 0 SERCOS startup de- tions and parameteriza- drive fault channels in
mands the NC to switch tion of the SERCOS ring. ”DIAGNOS-
back to SERCOS phase Initiate a new SERCOS TICS” group op-
0. Possible reasons: tele- startup. erating mode
gram failure, handshake
timeout or busy timeout in
the service channel,
wrong adjustment of
transmission times.
842 NCS: Client not signed Error on registration of No error recovery pos- Serious system System Restart
on. the task as client. sible! error
844 Selected SERCOS phase error in phase 0 transition No error recovery pos- Servo loop or Reset of all
could not be implemented sible! drive fault channels in
”DIAGNOS-
TICS” group op-
erating mode
847 System error in subsys- A precise statement No error recovery pos- Minor system System Restart
tem MCA or BMC (code about the error cause is sible! error
line %d) only possible after an ex-
amination by the develop-
ment department.
848 SERCOS Server not Error on installing the No error recovery pos- Serious system System Restart
installed! SERCOS server. sible! error
849 Interruption of the SER- Bit stream on the SER- Check glass fibers, drives Servo loop or Reset of all
COS ring COS ring interrupted, and connections. Initiate drive fault channels in
connection to the drives a new SERCOS startup! ”DIAGNOS-
interrupted. TICS” group op-
erating mode
850 SERCOS: Repeated Failure of two successive Check SERCOS configu- Servo loop or Reset of all
message failure drive telegrams of the ration, cable connections drive fault channels in
same address. The NC and drives. Initiate a new ”DIAGNOS-
switches back to phase 0. SERCOS startup. TICS” group op-
erating mode
851 SERCOS: Max. number Each command of the NC Check the environment of Serious system System Restart
of active commands ex- to a drive is inserted in a this problem so that a list error
ceeded (channel: %d) list. The capacity of this overflow is avoided.
list is limited. The error
occurs if the number of si-
multaneous active com-
mands is greater than 5.
852 SERCOS: ActCmdList in- The list of active com- No error recovery pos- Serious system System Restart
consistent! mands must be consis- sible! error
tent at all times. On ap-
pearance of this error the
consistency is suspect,
therefore due to an inter-
nal error, the list was de-
stroyed, and access to
the list was aborted with
an error.

1070 073 799-102 (02.05) GB


3–40 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


853 SERCOS: Communica- A command change bit No error recovery pos- Servo loop or System Restart
tion error %d (channel: sent by the drive causes sible! drive fault
%d) several communications
with the corresponding
drive. The communication
is handled in the service
channel. The cause for a
communication error is
usually a destroyed list of
active commands.
854 NCS: Client not signed The registration of the No error recovery pos- Serious system System Restart
on. SERCOS event task as a sible! error
client of the NCB didn’t
take place.
855 NCE-response error (%d) The list of the output files Correct list. Serious system System Restart
has an invalid format. The error
output has been aborted.
856 Response to client re- error in NCS-communica- No error recovery pos- Serious system System Restart
quest No error recovery tion sible! error
possible! (NCS)
857 Serious NCS communica- error in NCS-communica- No error recovery pos- Serious system System Restart
tion error tion sible! error
858 Output list incorrect. The list of the output files Correct list. DNC error by mode
has an invalid format. The change
output has been aborted.
859 Loading of %s: File al- During loading the indi- Delete the existing file DNC error by mode
ready exists. cated file the existence of and restart input once change
a file of the same name more.
was detected, hence
loading has been
aborted.
860 Output of %s: File name The indicated file name is Rename file. DNC error by mode
to incorrect. invalid. The output has change
861 been aborted.
862 Output of %s: File not The indicated file doesn’t Cancel your choice. DNC error by mode
found. exist. The output has change
been aborted.
863 Output of %s: File pro- The indicated file is pro- Change file protection. DNC error by mode
tected. tected, hence output is change
No error recovery pos-
sible!. The output has
been aborted.
864 Output of %s: File pro- The output package con- Change file protection. DNC error by mode
tected. tains a protected file. The change
output has been aborted.
865 Output of %s: Main pro- The output has been Create or copy main pro- DNC error by mode
gram missing. aborted. gram. change
866 Output of %s: File name The output package con- Rename file. DNC error by mode
incorrect. tains a file with invalid change
name. The output has
been aborted.
867 Error during output of %s During output of a file an Check protocol. DNC error by mode
error was reported by the change
computer. The output has
been aborted.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–41

No Error text Cause Correction Error class Reset mode


868 Output of %s No error re- The output of the indi- Retry output. DNC error by mode
covery possible!. cated file has been re- change
fused by the computer.
869 %s The output of the indi- Retry output. DNC error by mode
cated file has been re- change
fused by the computer.
870 Output of %s aborted The output of the indi- Possibly restart output. DNC error by mode
cated file has been change
aborted by the operator.
871 Input of %s No error re- The loading of the indi- Retry input. DNC error by mode
covery possible! cated file has been re- change
fused by the computer.
872 %s The loading of the indi- Retry input. DNC error by mode
cated file has been re- change
fused by the computer.
873 Error during input of %s. During loading a file an Check protocol. DNC error by mode
error was reported by the change
computer. The loading
has been aborted. Incom-
pletely transmitted files or
packages have been de-
leted.
874 Beginning-of-information In the input stream the Insert beginning-of-infor- DNC error by mode
marker missing. beginning-of-information- mation-marker. change
marker (control character
STX) of a file is missing.
The loading has been
aborted. No package was
created.
875 Loading of %s: DFS-iden- The DFS recognition of Check DFS identification. DNC error by mode
tification incorrect. the input file is wrong. change
The loading has been
aborted. Incompletely
transmitted files or pack-
ages have been deleted.
876 Loading of %s: Different The file name in the DFS Check protocol on com- DNC error by mode
name in DFS-identifica- recognition doesn’t corre- puter end. change
tion. spond with the name of
the requested file. The
loading has been aborted
and no new file or pack-
age was created.
877 Loading of %s: Main pro- The main program in the During input of packages DNC error by mode
gram missing. input package is missing. the main program must change
The loading has been be transferred first.
aborted and no new
package has been
created.
878 Loading of %s: Memory There is not enough me- Enlarge memory and re- DNC error by mode
full. mory space to store the start input. change
input files. The loading
has been aborted. Incom-
pletely transmitted files or
packages have been de-
leted.

1070 073 799-102 (02.05) GB


3–42 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


879 Loading of %s: File data The input file contains in- Check file and package. DNC error by mode
incorrect. valid data. The loading change
has been aborted. The
faulty file or package has
been deleted.
880 Loading of %s: Data after Undefined data have Check file. DNC error by mode
to end identifier. been transmitted after the change
881 end recognition. The
loading has been aborted
and no new file or pack-
age has been created.
882 Loading of %s: End iden- The file or package con- Insert end identifier. DNC error by mode
tifier missing tains no end identifier. change
The loading has been
aborted. No new file or
package respectively has
been created.
883 Loading of %s aborted The loading of the indi- Possibly restart input. DNC error by mode
cated file has been change
aborted by the operator.
Incompletely transmitted
files or packages have
been deleted.
884 Transmission link dis- The connection to the Check connection cable. DNC error by mode
rupted DNC computer is inter- change
rupted, therefore no LSV2
telegrams can be sent by
the NC control.
885 Computer not ready to re- The DNC computer does Check DNC computer. DNC error by mode
ceive not accept any more change
LSV2 telegrams (receive
command is acknowl-
edged negatively).
886 Error during input of %s. During loading a file an Check protocol. DNC error by mode
error was reported by the change
computer. The loading
has been aborted. Incom-
pletely transmitted files or
packages have been de-
leted.
887 System error in subsys- A precise statement No error recovery pos- Minor system System Restart
to tem MCA or BMC (code about the error cause is sible! Please report error error
889 line %d) only possible after an ex- data and detailed soft-
amination byy the develop-
p ware version to the after
ment department. sales service of the NC
manufacturer.
890 SERCOS phase 3, data In order to initialize the in- Check the ident number, Servo loop or Reset of all
error drive %d IdNo %d terpolation the NC must e.g. with the help of SER- drive fault channels in
detect the interface type COS monitor, and initiate ”DIAGNOS-
and the encoder type a new SERCOS startup. TICS” group op-
from the main operation erating mode
mode parameter
S-0-0032.During loading
ident number S-0-0032
an error occurred!

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–43

No Error text Cause Correction Error class Reset mode


891 No position interface for In MACODA this axis is Check ident number Servo loop or Reset of all
%s-axis specified (%s) applied as feed axis. For S-0-0032 and adjust posi- drive fault channels in
this adjustment it is also tion control interface in ”DIAGNOS-
necessary that the posi- the drive if necessary. TICS” group op-
tion control is configured erating mode
in the main operation
mode of the drive.
892 SERCOS phase 3, data Communication fault dur- Check the ident number, Servo loop or Reset of all
error drive %d IdNo %d ing loading the reference e.g. with the help of SER- drive fault channels in
point of the drive. COS monitor, and initiate ”DIAGNOS-
a new SERCOS startup. TICS” group op-
erating mode
893 SERCOS runup aborted Due to a simple commu- Check download data re- Servo loop or Reset of all
due to an error nication fault while load- cord, adjust it if neces- drive fault channels in
ing the drive parameters sary and initiate a new ”DIAGNOS-
to the drive the SERCOS SERCOS startup. TICS” group op-
startup has been aborted. erating mode
894 APS: Operand address The operand address is Change the operand ad- PLC error Restart of PLC
%d too high for address greater than the corre- dress in MACODA and program
range %d sponding operand range restart the PLC program
within the ICL. Address (with programming de-
ranges: 0 - address range vice) or initiate a new sys-
of axes related signals, 1 tem startup (without pro-
- address range of gramming device).
spindle related signals, 2
- address range of chan-
nel related signals, 3 - ad-
dress range of MSD, 4 -
address range of bit
coded auxiliary functions,
5 - address range of 32
bit BCD coded auxiliary
functions, 6 - address
range of 64 bit BCD
coded auxiliary functions.
895 APS: Ncs error %d in %x A NCS function called in No error recovery pos- PLC error Restart of PLC
the subsystem APS re- sible! program
turned an error.
896 APS: No memory block The request for memory No error recovery pos- PLC error Restart of PLC
available for job process- space for the internal sible! program
ing in %x for function %d management list could
not be satisfied. Hence
the called function could
not be performed. The
reason is a too frequently
loading of client modules,
while these modules are
waiting for a response
from the NC.
897 APS: NCB error %d with A request for memory No error recovery pos- PLC error Restart of PLC
request of communication space via the dual port sible! program
memory could not be satisfied.
898 APS: NCB error %d with Error on requesting the No error recovery pos- PLC error Restart of PLC
request of handler struc- handler structure for sible! program
ture copying the NC bit inter-
face.

1070 073 799-102 (02.05) GB


3–44 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


899 APS: Invalid operand The operand type is not Change the operand ad- PLC error Restart of PLC
type %s for address defined or invalid. dress in MACODA and program
range %d Address ranges: restart the PLC program
0 - address range of axes (with programming de-
related signals, vice) or initiate a new sys-
1 - address range of tem startup (without pro-
spindle related signals, gramming device).
2 - address range of
channel related signals, 3
- address range of MSD,
4 - address range of bit
coded auxiliary functions,
5 - address range of 32
bit BCD coded auxiliary
functions,
6 - address range of 64
bit BCD coded auxiliary
functions.
900 APS: Incorrect service An unknown service was No error recovery pos- PLC error Restart of PLC
%d in job list detected within the inter- sible! program
nal management list.
901 APS: PxRos error %d PXROS returns an error No error recovery pos- PLC error Restart of PLC
when creating storage on installing the memory sible! program
class class for APS.
902 APS: Error %d when MACODA returns an er- No error recovery pos- PLC error Restart of PLC
reading machine parame- ror on reading MACODA sible! program
ters parameters. APS cannot
complete the initialization.
903 Main program %s does A part program has been Repeat program selection Part program Reset of current
not exist selected which doesn’t with a program. error channel
exist.
904 APS: No call of On calling a client module Insert as first command in PLC error Restart of PLC
B01APSMN in organiza- the APS memory class OM1 an unconditional call program
tion module OM1 could not be accessed, of the program module
because the APS initiali- B01APSMN and restart
zation was not completely the PLC program.
performed.
905 LSEC: Error when read- Possibly the indicated line Edit the indicated file and Minor system System Restart
ing line %d, file %s! contains only one instead adjust the number format. error
of two required numbers. Initiate a system startup.
Both numbers must be A general failure of the
separated by a space standard file I/O should
character. An error within be investigated by the NC
the standard file I/O manufacturer.
(fscanf) also causes this
error message.
906 LSEC: One of the num- In the first line of the files Edit the indicated file and Minor system System Restart
bers in line %d, file %s is lsec?.tab only numbers adjust the numbers to the error
too high! between -214748364.7 allowed range of values.
and +214748364.7 are al- Initiate a system startup.
lowed. In all following
lines the limits are
-3276.7 and +3276.7.
907 LSEC: Maximum number The maximum number of Edit the indicated file and Minor system System Restart
of LSEC values in line correction values in the reduce the number of val- error
%d, file %s exceeded! files lsec?.tab may not ues. Initiate a system
exceed 8000 at present. startup.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–45

No Error text Cause Correction Error class Reset mode


908 Installation of start task Internal software error. No error recovery pos- Serious system System Restart
No error recovery pos- sible! error
sible!
909 Invalid SVC call Internal software error. No error recovery pos- Serious system System Restart
sible! error
910 Non-vectored interrupt Internal software error. No error recovery pos- Serious system System Restart
sible! error
911 Error during saving of Internal software error. No error recovery pos- Serious system System Restart
subsystem table or dis- sible! error
patch table
912 Error with initialization of Internal software error. No error recovery pos- Serious system System Restart
TID memory sible! error
913 Error with initialization of Internal software error. No error recovery pos- Serious system System Restart
interrupt logic sible! error
914 Error in subsystem inter- Internal software error. No error recovery pos- Serious system System Restart
face sible! error
915 Invalid start address of Internal software error. No error recovery pos- Serious system System Restart
TID-protectable memory sible! error
916 Invalid length of TID-pro- Internal software error. No error recovery pos- Serious system System Restart
tectable memory sible! error
917 Error in configuration of Internal software error. No error recovery pos- Serious system System Restart
dual port sible! error
918 Error in file system The start address of the No error recovery pos- Serious system System Restart
header RAM file system is invalid sible! error
919 Invalid start address of Internal software error. No error recovery pos- Serious system System Restart
file system sible! error
920 Invalid file system length. Internal software error. No error recovery pos- Serious system System Restart
sible! error
921 RAM module for file sys- Internal software error. No error recovery pos- Serious system System Restart
to tem not found sible! error
923
924 Invalid file system length. This is a problem of the Start up with mode 6. Serious system System Restart
to RAM file system exten- Perhaps the PC Card error
925 sion. The PC-Card is must be changed.
probably defective.
926 Invalid offset address for This is a problem of the Start up with mode 6. Serious system System Restart
to file system extension RAM file system exten- Perhaps the PC Card error
927 sion. The PC-Card is must be changed.
probably defective.
928 Invalid start address of The FEPROM file system No error recovery pos- Serious system System Restart
to file system is defective. sible! error
929
930 Invalid file system length. The FEPROM file system No error recovery pos- Serious system System Restart
is defective. sible! error
931 Invalid file system length. The ’usrfep’ file system is Startup with mode 7, per- Serious system System Restart
defective. haps then startup with error
mode 6.
932 Error in file system The ’usrfep’ file system is Startup with mode 7, per- Serious system System Restart
header defective. haps then startup with error
mode 6.
933 Invalid start address of The ’usrfep’ file system is Startup with mode 7, per- Serious system System Restart
file system defective. haps then startup with error
mode 6.

1070 073 799-102 (02.05) GB


3–46 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


934 Error in hardware config- Internal software error. No error recovery pos- Serious system System Restart
uration sible! error
935 Invalid start address of This is a problem of the Start up with mode 6. Serious system System Restart
to file system RAM file system exten- Perhaps the PC Card error
936 sion. The PC-Card is must be changed.
probably defective.
937 No error text No free memory in task No error recovery pos- Serious system System Restart
default- or protected- me- sible! error
mory class
938 Error during generating or Internal software error. No error recovery pos- Serious system System Restart
to filling of a memory class. sible! error
939
940 Error in trap handling. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
941
942 Trap %x occurred near Internal software error. No error recovery pos- Serious system System Restart
address %x sible! error
943 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
to PSR: %x SP0: %x SP1: sible! error
948 %x FP: %x.
949 Illegal operation in inter- Internal software error. No error recovery pos- Serious system System Restart
to rupt with number %x at sible! error
953 address %x.
954 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
to PSR: %x SP0: %x SP1: sible! error
955 %x FP: %x.
956 Division by zero in task Internal software error. No error recovery pos- Serious system System Restart
to with Id %x at address %x. sible! error
961
962 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
to PSR: %x SP0: %x SP1: sible! error
963 %x FP: %x.
964 Undefined operation code Internal software error. No error recovery pos- Serious system System Restart
to in task with Id %x at ad- sible! error
972 dress %x PSR: %x SP0:
%x SP1: %x FP: %x
973 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x.
974 Error in trap handling. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
979
980 FPU-Trap %x occurred at Internal software error. No error recovery pos- Serious system System Restart
to address %x sible! error
982
983 FPU-Trap %x in task with Internal software error. No error recovery pos- Serious system System Restart
to Id %x at address %x oc- sible! error
984 curred
985 Task control block of task Internal software error. No error recovery pos- Serious system System Restart
to with Id %x is defective. sible! error
986
987 Insufficient runtime me- No free memory in task No error recovery pos- Serious system System Restart
mory available default- or protected- me- sible! error
mory class

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–47

No Error text Cause Correction Error class Reset mode


988 File system defective. The RAM-file system is Start up with mode 6. Serious system System Restart
Cold start required defective or too big Perhaps the PC Card error
must be changed.
989 Error during saving of Internal software error. No error recovery pos- Serious system System Restart
subsystem table or dis- sible! error
patch table
990 File system defective. The RAM-file system is No error recovery pos- Serious system System Restart
Cold start required defective or too big sible! error
991 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
992 Error %d with Ncs_Close. Internal software error. No error recovery pos- Serious system System Restart
sible! error
993 Error in abort logic. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
1007
1008 PXROS cannot be Internal software error. No error recovery pos- Serious system System Restart
started. sible! error
1009 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1010 Error in debug task. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
1011
1012 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1013 Error in debug task. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
1016
1017 Illegal operation in inter- Internal software error. No error recovery pos- Serious system System Restart
rupt with number %x at sible! error
address %x.
1018 Division by zero in inter- Internal software error. No error recovery pos- Serious system System Restart
rupt with number %x at sible! error
address %x.
1019 CPU-Server: Error: %s Internal software error. No error recovery pos- Serious system System Restart
sible! error
1020 CPU server: Ncs-error Internal software error. No error recovery pos- Serious system System Restart
%d sible! error
1021 CPU server: PXROS-er- Internal software error. No error recovery pos- Serious system System Restart
ror %d sible! error
1022 CPU server: Error %d Internal software error. No error recovery pos- Serious system System Restart
sible! error
1023 Task with Id %x not found Internal software error. No error recovery pos- Minor system System Restart
in task table. sible! error
1024 CPU server: Error %d Internal software error. No error recovery pos- Serious system System Restart
to sible! error
1025
1026 Floating point underflow Internal software error. No error recovery pos- Serious system System Restart
in interrupt number %x at sible! error
address %x.
1027 Task control block of task Internal software error. No error recovery pos- Serious system System Restart
with Id %x is defective. sible! error
1028 Reset of task with Id %d Internal software error. No error recovery pos- Minor system System Restart
No error recovery pos- sible! error
sible!

1070 073 799-102 (02.05) GB


3–48 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1029 Floating point overflow in Internal software error. No error recovery pos- Serious system System Restart
interrupt with number %x sible! error
at address %x.
1030 Division by zero in inter- Internal software error. No error recovery pos- Serious system System Restart
rupt with number %x at sible! error
address %x.
1031 Floating point underflow Internal software error. No error recovery pos- Serious system Reset of current
in task with Id %x at ad- sible! error channel
dress %x.
1032 Floating point overflow in Internal software error. No error recovery pos- Serious system Reset of current
task with Id %x at ad- sible! error channel
dress %x.
1033 Division by zero in task Internal software error. No error recovery pos- Serious system Reset of current
with Id %x at address %x. sible! error channel
1034 Floating point underflow Internal software error. No error recovery pos- Serious system Reset of current
in task with Id %x at ad- sible! error channel
dress %x.
1035 Floating point overflow in Internal software error. No error recovery pos- Serious system Reset of current
task with Id %x at ad- sible! error channel
dress %x.
1036 Division by zero in task Internal software error. No error recovery pos- Serious system Reset of current
with Id %x at address %x. sible! error channel
1037 Illegal operation in task Internal software error. No error recovery pos- Serious system Reset of current
with Id %x at address %x. sible! error channel
1038 Illegal operation in inter- Internal software error. No error recovery pos- Serious system Reset of current
to rupt with number %x at sible! error channel
1045 address %x.
1046 Division by zero in task Internal software error. No error recovery pos- Serious system Reset of current
to with Id %x at address %x. sible! error channel
1048
1049 Division by zero in inter- Internal software error. No error recovery pos- Serious system Reset of current
to rupt with number %x at sible! error channel
1056 address %x.
1057 CAN: Error during initiali- Internal software error. No error recovery pos- Serious system System Restart
to zation. sible! error
1060
1061 Panel %d defective or not According to the entry in Check cable or change Hardware error System Restart
connected. OM2 the indicated CAN- hardware module.
participant exists, but it
doesn’t respond.
1062 Machine operating panel According to the entry in Check cable or change Hardware error System Restart
%d defective or not con- OM2 the indicated CAN- hardware module.
nected. participant exists, but it
doesn’t respond.
1063 Error during transmission On transmitting keyboard Exchange the concerning Interface warn- in the Info dia-
of keyboard data (panel data via the CAN bus an hardware module if this ing log with softkey
%d). error occurred. The can error occurs frequently. ”Delete warn-
bus has been initialized ings”
once again.
1064 Error during transmission On transmitting MBF data Exchange the concerning Interface warn- in the Info dia-
of MBF data (machine via CAN bus an error oc- hardware module if this ing log with softkey
operating panel %d). curred. The CAN bus has error occurs frequently. ”Delete warn-
been initialized once ings”
again.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–49

No Error text Cause Correction Error class Reset mode


1065 CAN bus shutdown due Due to an excessive error Exchange the concerning Interface warn- in the Info dia-
to high error rate. rate on the CAN bus a hardware module if this ing log with softkey
bus shutdown with a re- error occurs frequently. ”Delete warn-
initialization has been ings”
performed.
1066 Bus warning due to high The CAN module reports Exchange the concerning Interface warn- in the Info dia-
error rate on CAN bus. a high error rate during hardware module if this ing log with softkey
transmitting the MBF- and error occurs frequently. ”Delete warn-
keyboard data. ings”
1067 Bus warning from panel On transmitting keyboard Exchange the concerning Interface warn- in the Info dia-
%d. data via CAN bus a high hardware module if this ing log with softkey
error rate was reported. error occurs frequently. ”Delete warn-
ings”
1068 Outputs are cleared! The Switch ”Clear Out- Switch off switch ”Clear PLC error System Restart
put” located on the ICL Output” on the ICL hard-
module is turned on or ware module or deacti-
the programming device vate the function ”Clear
has activated this func- Outputs” by means of the
tion. programming device.
1069 Bus warning from ma- On transmitting machine- Exchange the concerning Interface warn- in the Info dia-
chine operating panel operating-panel data via hardware module if this ing log with softkey
%d. CAN bus a high error rate error occurs frequently. ”Delete warn-
was reported. ings”
1070 Error %d in converter Internal system error in No error recovery pos- Serious system System Restart
from NCS to PLC system the ICL firmware. sible! error
command (detail %d).
1071 Machine operating panel Due to an excessive error Exchange the concerning Interface warn- in the Info dia-
%d signals bus mode rate on the CAN bus the hardware module if this ing log with softkey
switchover. indicated CAN participant error occurs frequently. ”Delete warn-
reports a bus mode ings”
switch.
1073 APS: %x: Incorrect NCS On calling a NCS function Copy the matching mo- PLC error Restart of PLC
library version. the APS detects that the dule NCS_LIB.PAH, bind program
version of the library mo- and load the PLC user
dule NCS_LIB.PAH program once more.
(OM52) doesn’t corre-
spond to the version of
the APS module.
1074 Auxiliary function is not The auxiliary function Modify part program or Part program Reset of current
defined. used in the NC program define auxiliary function in error channel
is not defined in MA- MACODA.
CODA.
1075 Auxiliary function not in The address of the pro- Modify part program. Part program Reset of current
valid range. grammed auxiliary func- error channel
tion is out of bounds.
1076 APS: Library module in On starting the PLC user Enter NCS_LIB.PAH in PLC error Restart of PLC
NCS_LIB not linked to program the APS detects the symbol table of program
PLC program as OM52. that the required library OM52, bind and load the
module NCS_LIB.PAH PLC user program once
has not been linked as more.
OM52 to the PLC pro-
gram.

1070 073 799-102 (02.05) GB


3–50 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1077 Definition of auxiliary The definitions of the aux- Define acknowledgment Minor system System Restart
function not complete in iliary functions in MA- flags to all bit coded auxil- error
MACODA. CODA are not complete. iary functions or insert en-
tries for each auxiliary
function in the different
MACODA groups.
1078 User index %d of file ser- Internal software error. No error recovery pos- Serious system System Restart
ver outside valid range. sible! error
1079 Inconsistent file server Internal software error. No error recovery pos- Serious system System Restart
status sible! error
1080 Environment of file sys- Internal software error. No error recovery pos- Serious system System Restart
tem user %s cannot be sible! error
adjusted
1081 Inconsistent file server Internal software error. No error recovery pos- Serious system System Restart
status sible! error
1082 Fatal error during file ser- Internal software error. No error recovery pos- Serious system System Restart
to ver startup %d %d. sible! error
1094
1095 Fatal file system error %s Internal software error. No error recovery pos- Serious system System Restart
: Reset regenerates file sible! error
system!!
1096 PXROS file system error Internal software error. No error recovery pos- Serious system System Restart
%s : Warm start performs sible! error
file system check!!
1097 File system check failed: Internal software error. No error recovery pos- Serious system System Restart
Reset regenerates file sible! error
system!!
1098 Fatal error during file ser- Internal software error. No error recovery pos- Serious system System Restart
to ver startup %d %d. sible! error
1102
1103 APS: Incorrect magic On receiving a response No error recovery pos- PLC error Restart of PLC
number in response mes- from the NC the magic sible! program
sage in %x. number is not correct.
The response is rejected.
1104 Panel %d signals bus Due to an excessive error Exchange the concerning Interface warn- in the Info dia-
mode switchover. rate on the CAN bus the hardware module if this ing log with softkey
indicated CAN participant error occurs frequently. ”Delete warn-
reports a bus mode ings”
switch.
1106 Unknown block number Wrong instructions for Select the correct block Part program Reset of current
%s. ”search block”. number for ”search block” warning channel
with or after program
selection.
1107 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
parameter for Unit. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1108 Invalid float value. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1109 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
parameter for Unit. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–51

No Error text Cause Correction Error class Reset mode


1113 Invalid integer value. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1115 Parameter missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1116 Option inactive. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1117 Parameter missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1118 Variable %s not used. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1119 Invalid variable %s. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
1120 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1121 Invalid allocation. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1122 Division by zero. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1123 Incorrect field index at Programming error at Correct programming er- Part program Reset of current
%s. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1124 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1125 Invalid variable %s. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1127 End of file. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1129 File destroyed. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1130 Invalid logical number. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–52 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1131 File not opened. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1132 Invalid file name. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1133 Invalid component length. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1134 Right parenthesis miss- Programming error at Correct programming er- Part program Reset of current
ing. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1135 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1136 File is locked Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1137 File is protected. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1138 Illegal file size. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1139 PRN format incorrect. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1140 Invalid float value. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1142 Invalid logical number. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1143 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1144 Insufficient memory for Too large values for stack Reduce data ranges in Part program Reset of current
data areas of CPL pro- and link table are defined MACODA parameter error channel
grams. in MACODA block num- 707000010 and initiate a
ber 707000010 ”Data new system startup.
areas for CPL programs”.
1145 Invalid component. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–53

No Error text Cause Correction Error class Reset mode


1147 Invalid format. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1148 Nesting too deep. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1149 Asynchronous interpola- During an axis motion a error not used. Part program in the Info dia-
tion channel in use/ axis new motion command warning log with softkey
moving. (e.g. by actuating the jog ”Delete warn-
key during incremental ings”
jog) occurred. This com-
mand will be ignored.
1150 Motion for axis %d great- The programming yields Check your part program. Part program Reset of current
er/equal 360 degrees. a motion of more than error channel
360 degrees for a modulo
rotary axis.
1151 Firmware error %x %x Internal system error in No error recovery pos- Serious system System Restart
%x %x. the ICL firmware. sible! error
1152 Output of %s No error re- Internal software error. No error recovery pos- DNC error by mode
to covery possible!. sible! change
1154
1155 Loading of %s: File not Internal software error. No error recovery pos- DNC error by mode
to created. sible! change
1156
1157 Conversion table %s not Error reading the conver- Check if the table exists DNC error by mode
activated. sion table defined in in the file system and change
MACODA parameter verify its format.
408600009.
1158 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1159 Error %d with Ncs_Close. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1160 Error during initialization Internal software error. No error recovery pos- Serious system System Restart
to of subsystem SIO. sible! error
1166
1167 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1168 Error during initialization Internal software error. No error recovery pos- Serious system System Restart
of subsystem SIO. sible! error
1169 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1170 Error %d with Ncs_Close. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1171 Error during initialization Internal software error. No error recovery pos- Serious system System Restart
to of subsystem SIO. sible! error
1179
1180 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1181 Error during initialization Internal software error. No error recovery pos- Serious system System Restart
to of subsystem SIO. sible! error
1185

1070 073 799-102 (02.05) GB


3–54 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1186 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
to tem SIO (code lines %d sible! error
1190 %d).
1191 Conversion table %s not Error reading the conver- Check if the table exists Interface error by mode
to activated. sion table defined in in the file system and change
1192 MACODA parameter verify its format.
405500014.
1193 Output list incorrect. Internal software error. No error recovery pos- Interface error by mode
sible! change
1194 Output of %s No error re- Internal software error. No error recovery pos- Interface error by mode
to covery possible!. sible! change
1196
1197 Output of %s: File name Internal software error. No error recovery pos- Interface error by mode
to incorrect. sible! change
1198
1199 Output of %s: File not Internal software error. No error recovery pos- Interface error by mode
found. sible! change
1200 Output of %s: File pro- The indicated file is pro- Change file protection. Interface error by mode
to tected. tected, hence output is change
1201 No error recovery pos-
sible!. The output has
been aborted.
1202 Output of %s: Main pro- The output has been Create or copy main pro- Interface error by mode
gram missing. aborted. gram. change
1203 Loading of %s: DFS iden- The DFS identification of Add DFS identification in Interface error by mode
tification missing. the input file is missing. the file on the external change
Loading has been device.
aborted. Incompletely
transmitted files or pack-
ages have been deleted
1204 Beginning-of-information In the input stream the Insert beginning-of-infor- Interface error by mode
marker missing. beginning-of-information- mation-marker. change
marker (control character
STX) of a file is missing.
The loading has been
aborted. No package was
created.
1205 Loading of %s: DFS-iden- The DFS recognition of Check DFS identification. Interface error by mode
tification incorrect. the input file is wrong. change
The loading has been
aborted. Incompletely
transmitted files or pack-
ages have been deleted.
1206 Loading of %s: Different The file name in the DFS Check file and application Interface error by mode
name in DFS-identifica- recognition doesn’t corre- on the external device. change
tion. spond with the name of
the requested file. The
loading has been aborted
and no new file or pack-
age was created.
1207 Loading of %s: Main pro- The main program in the During input of packages Interface error by mode
gram missing. input package is missing. the main program must change
The loading has been be transferred first.
aborted and no new
package has been
created.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–55

No Error text Cause Correction Error class Reset mode


1208 Loading of %s: Memory There is not enough me- Enlarge memory and re- Interface error by mode
full. mory space to store the start input. change
input files. The loading
has been aborted. Incom-
pletely transmitted files or
packages have been de-
leted.
1209 Loading of %s: File data The input file contains in- Check file and package. Interface error by mode
incorrect. valid data. The loading change
has been aborted. The
faulty file or package has
been deleted.
1210 Loading of %s: Data after Undefined data have Check file. Interface error by mode
end identifier. been transmitted after the change
end recognition. The
loading has been aborted
and no new file or pack-
age has been created.
1211 Loading of %s: File not File creation failed be- Change directory and re- Interface error by mode
to created. cause a protected direc- start file transfer. change
1212 tory has been selected.
1213 Loading of %s: File al- During loading the indi- Delete the existing file Interface error by mode
ready exists. cated file the existence of and restart input once change
a file of the same name more.
was detected, hence
loading has been
aborted.
1214 Loading of %s: Timeout File transfer has been Check connection and Interface error by mode
to occurred. aborted due to a timeout. application on the exter- change
1215 nal device.
Saving of %s: Timeout
occurred.
1216 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
1218
1219 Error during the initializa- Internal software error. No error recovery pos- Serious system System Restart
to tion of subsystem DNC. sible! error
1235
1236 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
to tem DNC (code lines %d sible! error
1239 %d).
1240 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1241 Error during the initializa- Internal software error. No error recovery pos- Serious system System Restart
to tion of subsystem DIA. sible! error
1249
1250 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1251 Error during the initializa- Internal software error. No error recovery pos- Serious system System Restart
to tion of subsystem DIA. sible! error
1252
1253 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
to tem DIA (code lines %d sible! error
1254 %d).

1070 073 799-102 (02.05) GB


3–56 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1255 CAN: Error during initiali- Internal software error. No error recovery pos- Serious system System Restart
to zation. sible! error
1271
1272 Error %d with Ncs_Open. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1274 Parameter overflow for Configuration of the NC- Try to simplify the NC- Part program Reset of current
NC function %s. syntax in the indicated block. If the error still oc- error channel
function is not correct. curs please report error
data and detailed soft-
ware version to the after
sales service of the NC
manufacturer.
1275 Internal error during block Configuration of the NC- Try to simplify the NC- Part program Reset of current
reading at %s. syntax in the indicated block. If the error still oc- error channel
function is not correct. curs please report error
data and detailed soft-
ware version to the after
sales service of the NC
manufacturer.
1276 Parameter %s cannot be Configuration of the NC- Try to simplify the NC- Part program Reset of current
allocated. syntax in the indicated block. If the error still oc- error channel
function is not correct. curs please report error
data and detailed soft-
ware version to the after
sales service of the NC
manufacturer.
1278 Number of parameters in Configuration of the NC- Try to simplify the NC- Part program Reset of current
NC block too high after syntax in the indicated block. If the error still oc- error channel
parameter %s. function is not correct. curs please report error
data and detailed soft-
ware version to the after
sales service of the NC
manufacturer.
1279 Parameter %s is ex- Configuration of the NC- Try to simplify the NC- Part program Reset of current
pected by several NC syntax in the indicated block. If the error still oc- error channel
functions. function is not correct. curs please report error
data and detailed soft-
ware version to the after
sales service of the NC
manufacturer.
1280 Internal error during block Configuration of the NC- Try to simplify the NC- Part program Reset of current
to reading at %s. syntax in the indicated block. If the error still oc- error channel
1281 function is not correct. curs please report error
data and detailed soft-
ware version to the after
sales service of the NC
manufacturer.
1282 Too many nested subpro- Nesting depth of subpro- Try to change the pro- Part program Reset of current
gram calls in %s. gram calls exceeded! gram structure in a way error channel
that there are not so
much nested subprogram
calls.
1283 PXROS error %d . Me- Internal software error. No error recovery pos- Serious system System Restart
to mory class cannot be sible! error
1285 created.
1286 Error during generating or Internal software error. No error recovery pos- Serious system System Restart
filling of a memory class. sible! error

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–57

No Error text Cause Correction Error class Reset mode


1287 Error during generating Internal software error. No error recovery pos- Serious system System Restart
the stack for the IdleTask. sible! error
1288 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Overload cut-off %s-axis. 1 error occurs, the drive the active channel. drive fault channel
attempts the best pos-
sible response with a
subsequent torque re-
lease.
1289 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Amplifier overtemperature 1 error occurs, the drive the active channel. drive fault channel
cut-off %s-axis. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1290 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Motor overtemperature 1 error occurs, the drive the active channel. drive fault channel
cut-off %s-axis attempts the best pos-
sible response with a
subsequent torque re-
lease.
1291 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Cooling fault cut-off %s- 1 error occurs, the drive the active channel. drive fault channel
axis. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1292 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Control voltage fault %s- 1 error occurs, the drive the active channel. drive fault channel
axis. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1293 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Encoder fault %s-axis. 1 error occurs, the drive the active channel. drive fault channel
attempts the best pos-
sible response with a
subsequent torque re-
lease.
1294 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Error in electronic com- 1 error occurs, the drive the active channel. drive fault channel
mutation system %s-axis. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1295 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Overcurrent fault %s-axis. 1 error occurs, the drive the active channel. drive fault channel
attempts the best pos-
sible response with a
subsequent torque re-
lease.
1296 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Over-voltage fault %s- 1 error occurs, the drive the active channel. drive fault channel
axis. attempts the best pos-
sible response with a
subsequent torque re-
lease.

1070 073 799-102 (02.05) GB


3–58 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1297 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Under-voltage fault %s- 1 error occurs, the drive the active channel. drive fault channel
axis. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1298 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Phase fault in power sup- 1 error occurs, the drive the active channel. drive fault channel
ply %s-axis. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1299 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Servo error %s-axis. 1 error occurs, the drive the active channel. drive fault channel
attempts the best pos-
sible response with a
subsequent torque re-
lease.
1300 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Interface error %s-axis. 1 error occurs, the drive the active channel. drive fault channel
attempts the best pos-
sible response with a
subsequent torque re-
lease.
1301 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Position limit of %s-axis 1 error occurs, the drive the active channel. drive fault channel
exceeded. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1302 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Unspecified error %s- 1 error occurs, the drive the active channel. drive fault channel
axis. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1303 SERCOS state class 1: If a SERCOS state class Initiate a control reset in Servo loop or Reset of current
Manufacturer-specific er- 1 error occurs, the drive the active channel. drive fault channel
ror %s-axis %s. attempts the best pos-
sible response with a
subsequent torque re-
lease.
1304 MACODA parameter %d The activation of this MA- Initiate a system startup. Core system System Restart
can only be transferred CODA parameter re- warning
with control startup. quires a startup of the
NC.
1305 System error during proc- Internal software error. No error recovery pos- MMI error System Restart
essing of ICL-data (code sible!
lines %d %d).
1306 Error in VGA-Init. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1308 Zero offset table not Programming error at Correct programming er- Part program Reset of current
found. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–59

No Error text Cause Correction Error class Reset mode


1309 Access to zero offset Programming error at Correct programming er- Part program Reset of current
to table No error recovery CPL - command. Further ror. Select part program error channel
1310 possible!. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1311 FXC-command with in- Programming error at Correct programming er- Part program Reset of current
valid parameters. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1312 Error in accessing zero Programming error at Correct programming er- Part program Reset of current
to offset table. CPL - command. Further ror. Select part program error channel
1314 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1315 Correction table not Programming error at Correct programming er- Part program Reset of current
found. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1316 Access to correction table Programming error at Correct programming er- Part program Reset of current
to No error recovery pos- CPL - command. Further ror. Select part program error channel
1317 sible!. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1318 TC command with invalid Programming error at Correct programming er- Part program Reset of current
parameters. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1319 Error in accessing correc- Programming error at Correct programming er- Part program Reset of current
to tion table. CPL - command. Further ror. Select part program error channel
1321 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1322 FXC command with in- Programming error at Correct programming er- Part program Reset of current
valid number of parame- CPL - command. Further ror. Select part program error channel
ters. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1323 TC command with invalid Programming error at Correct programming er- Part program Reset of current
number of parameters. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1324 TID error: PC %x SP %x Internal software error. No error recovery pos- Serious system System Restart
TID %x PSR %x. sible! error
1325 Error in erasing data FE- Internal software error. No error recovery pos- Serious system System Restart
PROM. sible! error
1326 Error in writing data FE- Internal software error. No error recovery pos- Serious system System Restart
PROM. sible! error
1327 FEPROM file system de- The FEPROM file system No error recovery pos- Serious system System Restart
fective. is defective. sible! error
1328 usrfep file system defec- The ’usrfep’ file system is Startup with mode 7, per- Serious system System Restart
tive. defective. haps then startup with error
mode 6.
1329 System error in process- Internal software error. No error recovery pos- MMI error System Restart
to ing of info data (code sible!
1330 lines %d %d).
1331 The PLC program is in The cause of the error is Modify and download the PLC error Restart of PLC
STOP state because of displayed by the next er- PLC program to the PLC. program
an error. ror message at info-dia-
log.

1070 073 799-102 (02.05) GB


3–60 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1332 The PLC program was The PLC program has Switch PLC program to PLC error Restart of PLC
set in STOP state by the been set into the STOP ”RUN” with the help of the program
operator. state by the programming programming device
device. monitor.
1333 The PLC program is in The PLC user program Change switch on NC PLC error Restart of PLC
STOP state because of doesn’t start with switch module to another posi- program
switch position ”1” on the position ”1” on the SM tion (for instance ”0”) and
SM-module. module. initiate a new system
startup or switch PLC
program to ”RUN” with
the help of the program-
ming device monitor.
1334 Error in opening group file cannot open SCS-file check SCS-file Servo loop or Reset of all
%s. drive fault channels in
”DIAGNOS-
TICS” group op-
erating mode
1335 Axis list syntax error in lo- wrong axis list in SCS-file check SCS-file Servo loop or Reset of all
cal group %s line %d. drive fault channels in
”DIAGNOS-
TICS” group op-
erating mode
1336 Missing FOR-instruction missing for statement in check SCS-file Servo loop or Reset of all
in main group %s line SCS-file drive fault channels in
%d. ”DIAGNOS-
TICS” group op-
erating mode
1337 Invalid local group name missing file name in SCS- check SCS-file Servo loop or Reset of all
%s in line %d. file drive fault channels in
”DIAGNOS-
TICS” group op-
erating mode
1338 Missing USE instruction missing use statement in check SCS-file Servo loop or Reset of all
in main group %s line SCS-file drive fault channels in
%d. ”DIAGNOS-
TICS” group op-
erating mode
1339 No value specified in lo- missing variable in use check SCS-file Servo loop or Reset of all
cal group %s line %d. statement drive fault channels in
”DIAGNOS-
TICS” group op-
erating mode
1340 Data error in %s (%s- drive doesn’t accept id- compare ident. number Servo loop or Reset of all
axis). ent. number of SCS-file value of SCS-file with drive fault channels in
min/max value in drive ”DIAGNOS-
TICS” group op-
erating mode
1341 Program selection er- A part program has been Repeat program selection Part program Reset of current
ror:”%s” is a file directory. selected which doesn’t with a program. error channel
exist.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–61

No Error text Cause Correction Error class Reset mode


1342 Initialization channel me- When creating channels It is necessary to make Serious system System Restart
mory: TID protected me- internal memory is more memory available error
mory empty (%d bytes re- needed. But there is no for the system for exam-
quested). more memory available. ple by decreasing the
number of channels (MA-
CODA block no.
904000001) or decreas-
ing the number of blocks
in the preparation
(MACODA block no.
7060000110) or decreas-
ing the memory area for
CPL programs
(MACODA block no.
707000010). The avail-
able free memory is indi-
cated under Diagnosis ->
Control -> Memory -> Me-
mory 2.
1343 Database read error for The indicated MACODA Possibly the file system is Minor system System Restart
to MACODA parameter %d. parameter can not be defective. A system error
1345 read. startup with switch posi-
tion ”6” creates a new file
system.
1346 Illegal operation in task Internal software error. No error recovery pos- Serious system System Restart
with Id %x at address %x. sible! error
1347 Illegal operation in task Internal software error. No error recovery pos- Serious system Reset of current
with Id %x at address %x. sible! error channel
1348 Illegal operation in inter- Internal software error. No error recovery pos- Serious system System Restart
rupt with number %x at sible! error
address %x.
1349 SERCOS not ready. The SERCOS ring is in Check SERCOS configu- Part program Reset of current
phase 1, 2 or 3 and ration, cable connections error channel
hence not ready to oper- and drives. Initiate a new
ate. SERCOS startup.
1350 Error during reading of The error usually occurs Eliminate the connection Part program Reset of current
to file. during input from external disturbance to external error channel
1351 sources (e.g. NFS) that source (e.g. net load of
do not respond any more, NFS too high).
so that a timeout occurs.
1352 Initialization auxiliary Internal system error! No error recovery pos- Serious system System Restart
to function list: TID pro- sible! error
1353 tected memory empty
(when %d bytes re-
quested).
1354 Not integer number. Error in the NC program: Correct the NC-part pro- Part program Reset of current
A number defined in CPL gram. error channel
cannot be represented
with the 32-bit integer for-
mat.
1355 Floating point number Error in the NC program: Correct the NC-part pro- Part program Reset of current
with %d digits cannot be A number defined in CPL gram. error channel
represented. cannot be represented
with the 32-bit integer for-
mat.
1356 Negative feedrate value For feedrate only positive Please change your MDI Part program Reset of current
is illegal! values are valid. respectively in the part error channel
program.

1070 073 799-102 (02.05) GB


3–62 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1357 The end marker is lo- Wrong instructions for Part program in the Info dia-
to cated before the start ”search block”. warning log with softkey
1358 marker. ”Delete warn-
ings”
1359 Insufficient memory for Too large values for stack Reduce data ranges in Part program Reset of current
data areas of CPL pro- and link table are defined MACODA parameter error channel
grams. in MACODA block num- 707000010 and initiate a
ber 707000010 ”Data new system startup.
areas for CPL programs”.
1360 TID protected memory When creating a commu- It is necessary to make Serious system System Restart
to empty (when %d bytes nication task internal me- more memory available error
1364 requested). mory is needed. But there for the system for exam-
is no more memory avail- ple by decreasing the
able. number of channels (MA-
CODA block no.
904000001) or decreas-
ing the number of blocks
in the preparation
(MACODA block no.
7060000110) or decreas-
ing the memory area for
CPL programs
(MACODA block no.
707000010). The avail-
able free memory is indi-
cated under Diagnosis –>
Control –> Memory –>
Memory 2.
1365 Error during initialization Internal software error. No error recovery pos- Serious system System Restart
of subsystem SIO. sible! error
1366 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
tem SIO (code lines %d sible! error
%d).
1367 Memory area of size zero Internal software error. No error recovery pos- Serious system System Restart
requested. sible! error
1368 Block pointer for a me- Internal software error. No error recovery pos- Serious system System Restart
mory block does not point sible! error
to the beginning of the
block.
1369 Memory area for TID Internal software error. No error recovery pos- Serious system System Restart
protection outside of sible! error
Pxr_mc_protected class.
1370 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x.
1371 Illegal operation in inter- Internal software error. No error recovery pos- Serious system System Restart
rupt with number %x at sible! error
address %x.
1372 Division by zero in inter- Internal software error. No error recovery pos- Serious system System Restart
rupt with number %x at sible! error
address %x.
1373 Undefined operation code Internal software error. No error recovery pos- Serious system System Restart
in interrupt with number sible! error
%x at address %x PSR:
%x SP0: %x SP1: %x FP:
%x.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–63

No Error text Cause Correction Error class Reset mode


1374 NC hardware: Maximum Temperature too high in Check the card rack fan. Hardware error System Restart
ambient temperature has the card rack.
been exceeded.
1375 NC hardware: Battery %d Battery is discharged. Do not power off the Hardware error System Restart
to is discharged or con- The power buffering of CNC. First change the
1376 nected with incorrect po- the static ram doesn’t battery.
larity. work.
1377 NC hardware: Overvol- The power supply is de- No error recovery pos- Hardware error System Restart
to tage on battery %d. PS fective. sible!
1378 monitor defective.
1379 NC hardware: Ready2 No ready signal. Probably The PLC user program Hardware error System Restart
contact is open. there is a watchdog prob- doesn’t start with switch
lem, or a critical system position ”1” on the SM
error. module.
1380 NC hardware: Fan defec- The fan in the rack or on No error recovery pos- Hardware error System Restart
tive. the CPU is defective sible!
1381 NC hardware: Error dur- Internal software error. No error recovery pos- Hardware error System Restart
ing initialization of I2C sible!
bus.
1382 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x.
1383 Task control block of task Internal software error. No error recovery pos- Serious system System Restart
with Id %x is defective. sible! error
1384 Breakpoint trap or trace Internal software error. No error recovery pos- Serious system System Restart
trap in task %x at address sible! error
%x PSR: %x SP0: %x
SP1: %x FP: %x.
1385 Breakpoint trap or trace Internal software error. No error recovery pos- Serious system System Restart
to trap in interrupt with no. sible! error
1393 %x at address %x PSR:
%x SP0: %x SP1: %x FP:
%x.
1394 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
to PSR: %x SP0: %x SP1: sible! error
1395 %x FP: %x.
1396 Error in trap handling. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1397 Polar coordinate pro- Wrong access to the in- No error recovery pos- Part program Reset of current
gramming: Invalid axis ternal mapping table or sible! error channel
number read from an in- wrong axis number in
ternal table. table.
1398 Polar coordinate pro- Both axes of the selected Program only one axis of Part program Reset of current
gramming: Radius or ref- plane were programmed the selected plane. error channel
erence axis is ambigu- in one NC block.
ous.
1399 Polar coordinate pro- Circular blocks (G2, G3, Correct the part program: Part program Reset of current
gramming G12/G13: In- G12 or G13 are active) Program only axes which error channel
valid axis programmed. may only contain axes of belong to the selected
the selected plane (G17, plane.
G18, G19, G20).
1400 Index %d missing for MA- Wrong implementation of No error recovery pos- Part program in the Info dia-
CODA parameter %d. MACODA parameter. sible! warning log with softkey
”Delete warn-
ings”

1070 073 799-102 (02.05) GB


3–64 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1401 MACODA parameter %d Wrong implementation of No error recovery pos- Part program System Restart
does not exist. MACODA parameter. sible! error
1402 Startup in file %s line%d The entry in file ’startup’ Change the entry in file Interface warn- in the Info dia-
code (%d:%d). is not correct ’startup’. New start of the ing log with softkey
MMI ”Delete warn-
ings”
1405 SERCOS error during ref- drive-controlled homing No error recovery pos- Servo loop or Reset of current
erencing of %s-axis command cannot be in- sible! drive fault channel
terrupted
1406 SERCOS read error for cannot read SERCOS id- No error recovery pos- Servo loop or Reset of current
ident number %s (%s- ent. number sible! drive fault channel
axis).
1407 SERCOS write error for drive doesn’t accept No error recovery pos- Servo loop or Reset of current
ident number %s (%s- SERCOS ident. number sible! drive fault channel
axis).
1408 SERCOS command error drive doesn’t accept No error recovery pos- Servo loop or Reset of current
for ident number %s (%s- SERCOS command sible! drive fault channel
axis).
1410 System error in subsys- Internal software error. No error recovery pos- Minor system by mode
tem FMS (code lines %d sible! error change
%d).
1411 FMS: Error in configura- The configuration file is Don’t modify configura- DNC error by mode
tion file %s in line %d. corrupt and FMS configu- tion files with a standard change
ration fails. editor. Please provide the
original configuration file
generated by the PROFI-
BUS configurator.
1412 FMS: configuration file Filenames for configura- Enter correct project DNC error by mode
%s not found. tion files are derived from name in MACODA or change
the project name defined supply missing configura-
in MACODA parameter tion file.
408500005. The specified
file is missing.
1413 FMS: User address %d The station address en- Enter correct station ad- DNC error by mode
from MACODA is not tered in the PROFIBUS dress in MACODA or change
identical to user address configuration tool is differ- supply configuration file
%d of %s. ent from the station ad- with correct address.
dress defined in MA-
CODA parameter
408500001.
1414 FMS: Segment address The segment address en- Enter correct segment DNC error by mode
%d from MACODA is not tered in the PROFIBUS address in MACODA or change
identical to segment ad- configuration tool is differ- supply configuration file
dress %d of %s. ent from the segment ad- with correct address.
dress defined in MA-
CODA parameter
408500002.
1415 FMS: Baud rate from MA- The baud rate entered in Enter correct baud rate in DNC error by mode
CODA is not identical to the PROFIBUS configura- MACODA or supply con- change
baud rate of %s. tion tool is different from figuration file with correct
the baud rate defined in baud rate.
MACODA parameter
408500003.
1416 System error in subsys- Internal software error. No error recovery pos- Minor system by mode
to tem FMS (code lines %d sible! error change
1421 %d).

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–65

No Error text Cause Correction Error class Reset mode


1422 Error during initialization Internal software error. No error recovery pos- Serious system System Restart
to of subsystem FMS. sible! error
1428
1429 Tool data server: Error Internal software error. No error recovery pos- Serious system System Restart
to %d when transmitting da- sible! error
1430 tabase response.
1434 Tool data server: Data- Internal software error. No error recovery pos- Minor system System Restart
base error %d when es- sible! error
tablishing of connection.
1435 Tool data server: Data- Internal software error. No error recovery pos- Minor system System Restart
base error %d when sible! error
opening table.
1436 MACODA parameter %d ident. number doesn’t ac- compare MACODA value Minor system System Restart
(%s) is not being ac- cept MACODA value with min/max value of id- error
cepted by %s-axis. ent. number
1437 Function Pxr_GetTidProt- Memory problem while No error recovery pos- Serious system System Restart
Mem returns with error starting TCP/IP sible! error
number %d.
1438 Function Pxr_FreeTid- Memory problem while No error recovery pos- Serious system System Restart
ProtMem return with error starting block control sible! error
number %d.
1439 There is no feed rate pro- A motion can’t be execut- Please program the fee- Part program Reset of current
grammed. ing without a pro- drate needed in the part error channel
grammed feedrate. program or under MDI
with address F.
1440 Insufficient memory for The internal memory If necessary reduce the Part program Reset of current
tapping function. needed for function G32 number of blocks for error channel
is not available. The sys- block preparation in MA-
tem memory resources CODA or call your com-
are exhausted. petent Bosch service.
1441 Not all the axes contribut- For the tapping function it Please change the MA- Part program Reset of current
ing to tapping function are is necessary that feedfor- CODA settings (group error channel
controllable by feedfor- ward is available for all axes parameters, param-
ward. channel axes C-axes in- eter 1003 00009).
clusive (MACODA param-
eter).
1442 It is No error recovery The internal memory If necessary reduce the Part program Reset of current
to possible! to insert a block. needed for function G32 number of blocks for error channel
1443 The memory is not suffi- is not available. The sys- block preparation in MA-
cient for tapping function. tem memory resources CODA or call your com-
are exhausted. petent Bosch service.
1444 Look ahead could not be The internal memory If necessary reduce the Part program Reset of current
executed, therefore tap- needed for function G32 number of blocks for error channel
ping can’t be done. is not available. The sys- block preparation in MA-
tem memory resources CODA or call your com-
are exhausted. petent Bosch service.
1445 It is No error recovery The internal memory If necessary reduce the Part program Reset of current
possible! to insert a block. needed for function G32 number of blocks for error channel
The memory is not suffi- is not available. The sys- block preparation in MA-
cient for tapping function. tem memory resources CODA or call your com-
are exhausted. petent Bosch service.
1446 Memory protection fault in Internal software error. No error recovery pos- Serious system System Restart
dual ported RAM: PC %x sible! error
SP %x Slot-no. %x PSR
%x.

1070 073 799-102 (02.05) GB


3–66 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1447 Cannot write memory re- Internal software error. No error recovery pos- Serious system System Restart
to gion containing the file sible! error
1453 system.
1454 Tables: NCS-error (code Internal software error. No error recovery pos- Minor system System Restart
%d) sending message to sible! error
block control.
1455 Tables: NCS-error (code If this error occurs a basic No error recovery pos- Minor system System Restart
%d) reading MACODA problem in NCS commu- sible! error
parameters. nication is detected. Per-
haps MACODA parame-
ters couldn’t be read suc-
cessfully.
1456 Tables: data base error If this error occurs a basic No error recovery pos- Minor system System Restart
(code %d) reading MA- problem in NCS commu- sible! error
CODA parameters nication is detected. Per-
haps MACODA parame-
ters couldn’t be read suc-
cessfully.
1457 APS: library module On starting the PLC user Enter SPS_LIB.PAH in PLC error Restart of PLC
SPS_LIB not linked as program the APS detects, OM48 of the symbol program
OM48 to the PLC pro- that the required library table. Bind and load the
gram. module SPS_LIB.PAH PLC user program again.
has not been linked as
OM48 to the PLC pro-
gram.
1458 Error %d while mounting Mount of feprom file sys- If the file system ”usrfep” Minor system System Restart
the file system ”usrfep”. tem ”usrfep” was not suc- doesn’t exist, generate error
cessful. For the meaning ”userfep” by means of a
of the error number see system startup with
documentation of mount switch position ”7” (switch
file system. S1 located on NC mo-
dule). Attention: All data
in the root file system are
lost. If a ”PxfMount” error
occurs see error descrip-
tion of ”PxFile”. If a
”PxfMknod” error occurs
inform the after sales ser-
vice of the NC manufac-
turer.
1459 PC card is write pro- PC card is write protected Unlock write protection of Serious system System Restart
tected. with the help of its write the PC card error
protection switch.
1460 PC card cannot be writ- It is No error recovery Use a suitable PC card Serious system System Restart
ten. possible! to write the PC error
card because the PC
card is not an SRAM card
or it is defective or write
protected.
1461 PC card is not plugged in. There is no PC card in Plug in a PC card Serious system System Restart
PCMCIA slot. error
1462 Look ahead No error re- The interpolator cannot Reduce the depth of anal- Part program Reset of current
covery possible! due to process further blocks be- ysis in programs with cut- error channel
lack of resources. cause the block prepara- ter radius correction or
tion has no resources to cutter length correction.
prepare additional blocks.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–67

No Error text Cause Correction Error class Reset mode


1463 Number of inserted A NC function requires No error recovery pos- Part program Reset of current
blocks too large. too many resources to in- sible! error channel
sert internal blocks.
1464 Lack of resources in Block preparation re- No error recovery pos- Part program Reset of current
block control. quires too many re- sible! error channel
sources.
1465 The programmed NC Auxiliary function output Correct the NC-part pro- Part program Reset of current
code does not fit to a in BCD code is No error gram. error channel
BCD number. recovery possible! be-
cause format of data
(number of digits before/
after point, precision)
doesn’t match with the
format defined in MA-
CODA.
1466 No previous block pro- The NC function requires Correct the NC-part pro- Part program Reset of current
to grammed. a previous block. gram. error channel
1467
1468 System error in subsys- Internal software error. No error recovery pos- Minor system by mode
tem FMS (code lines %d sible! error change
%d).
1469 FMS: Message lost. PROFIBUS FMS commu- No error recovery pos- DNC error by mode
to nication error. sible! change
1472
1473 FMS: telegram rejected PROFIBUS FMS commu- No error recovery pos- DNC error by mode
(communication refer- nication error. sible! change
ence %d).
1474 FMS: object in configura- An error at the configura- Modify an download the DNC error by mode
tion file %s, line %d not tion file occurred. configuration file. change
accepted.
1475 Invalid file system length. Partition 0 of root file sys- The partition size of the Serious system System Restart
tem is too small. file system must be error
changed. To do that a
new system configuration
is necessary.
1476 Invalid file system length. Partition 1 of root file sys- The partition size of the Serious system System Restart
tem is too small. file system must be error
changed. To do that a
new system configuration
is necessary.
1477 Invalid file system length. Partition 2 of root file sys- The partition size of the Serious system System Restart
tem is too small. file system must be error
changed. To do that a
new system configuration
is necessary.
1478 Error while waiting in No PXROS object avail- No error recovery pos- Serious system System Restart
Pxr_Delay. Location: %d. able for creating a delay sible! error
structure.
1479 Trap %x at address: %x Serious software error. In- No error recovery pos- Serious system System Restart
to PSR: %x SP0: %x SP1: admissible value of SB sible! error
1483 %x FP: %x. register.
1484 FMS: Error in LLI (com- PROFIBUS FMS commu- No error recovery pos- DNC error by mode
munication reference: nication error. sible! change
%d, reason code: %d).
1485 FMS: Multiple user ad- PROFIBUS FMS commu- No error recovery pos- DNC error by mode
dresses. nication error. sible! change

1070 073 799-102 (02.05) GB


3–68 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1486 FMS: Transceiver faulty. PROFIBUS FMS commu- No error recovery pos- DNC error by mode
nication error. sible! change
1487 FMS: Timeout. PROFIBUS FMS commu- No error recovery pos- DNC error by mode
nication error. sible! change
1488 FMS: Receiver synchro- PROFIBUS FMS commu- No error recovery pos- DNC error by mode
nization failed. nication error. sible! change
1489 FMS: Station out of ring. PROFIBUS FMS commu- No error recovery pos- DNC error by mode
nication error. sible! change
1490 FMS: New station in ring. PROFIBUS FMS commu- No error recovery pos- DNC error by mode
nication error. sible! change
1491 Neither thread pitch nor The thread definition Program the thread Part program Reset of current
spindle speed pro- needs either spindle height or the spindle error channel
grammed. speed or the thread speed together with G32
height. in the same NC block.
1492 Please exchange battery PC card battery fails. Replace the battery of the Hardware error System Restart
on PC card. PC card.
1493 Battery on PC card is dis- PC card battery fails. Replace the battery of the Hardware error System Restart
charged or missing PC card.
1494 Illegal channel number. NCS function was called Modify parameter of NCS Part program in the Info dia-
with inadmissible channel function. warning log with softkey
number. ”Delete warn-
ings”
1495 Error %d while copying 1. Can’t copy a file: No 1. The FEPROM file sys- Serious system System Restart
file. permission to source-file. tem or the usrfep-file sys- error
Can’t create destination- tem must be changed. Or
file. Or 2. The root-file 2. The root file system
system is too small. Files must be enlarged. There-
for system startup cannot fore the configuration of
be created or copied. the system must be
changed and/or additional
RAM memory must be
made available.
1496 Statement not allowed in Modal states where Start NC block in ”manual Part program Reset of current
this channel. changed in an internal data input” instead of error channel
channel for example in ”machine functions”. If
jog mode channel or in necessary change the init
machine function chan- block of the this channel
nel. Only asynchronous in MACODA.
motions, auxiliary func-
tions and spindle com-
mands are permitted. The
error also occurs when
the init string of this chan-
nel changes a modal
state.
1497 Variable %s not used. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
1498 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1499 maximum block length of Programming error at Correct programming er- Part program Reset of current
%s byte exceeded CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1500 maximum block length of Programming error at Correct programming er- Part program Reset of current
%s byte exceeded CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–69

No Error text Cause Correction Error class Reset mode


1501 Invalid logical number. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1502 Invalid file name. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1503 Parameter missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1504 Invalid variable %s. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1505 Invalid file name. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1506 Invalid logical number. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1507 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1508 PRN format incorrect. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1509 maximum block length of Programming error at Correct programming er- Part program Reset of current
%s byte exceeded CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1510 Invalid component length. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1511 File destroyed. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1512 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1513 Invalid allocation. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1516 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–70 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1517 Invalid float value. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1518 Invalid parameter. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1519 Parameter missing. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1520 Write error while copying It is No error recovery No error recovery pos- Hardware error System Restart
boot parameters to FE- possible! to delete or pro- sible!
PROM. gram Feprom chip(s).
The following reasons are
possible: 1. The state ma-
chine of an FEPROM
chip is in an undefined
state because a reset oc-
curred while the FE-
PROM chip was pro-
grammed or an FEPROM
address area was over-
written unintentionally. 2.
FEPROM chip is defec-
tive.
1521 Erase error while copying There is no more dy- No error recovery pos- Hardware error System Restart
boot parameters to FE- namic memory available sible!
PROM. to store the boot parame-
ter.
1522 No memory for storing There is no more dy- No error recovery pos- Hardware error System Restart
the boot parameters tem- namic memory available sible!
porarily. to store the boot parame-
ter.
1523 Undefined Error while During handling of boot No error recovery pos- Hardware error System Restart
processing boot parame- parameters an undefined sible!
ters. error occurred.
1524 System error in subsys- Internal software error. No error recovery pos- Minor system by mode
tem FMS (code lines %d sible! error change
%d).
1525 Error during initialization Internal software error. No error recovery pos- Serious system System Restart
of subsystem FMS. sible! error
1527 Input from %s: data over- Loading of the specified Check settings of serial Interface error by mode
run. file fails due to a data port (e.g. handshake) and change
overrun. Loading has restart file transfer.
been aborted.
1528 Input from %s: Invalid pa- Loading of the specified Check settings of serial Interface error by mode
rameter of device. file fails due to a data port (e.g. baud rate, stop change
overrun. Loading has bits, parity) and restart file
been aborted. transfer.
1529 Output to %s: Invalid pa- Output of the specified Check settings of serial Interface error by mode
rameter of device. file fails due to transmis- port (e.g. baud rate, stop change
sion errors. Output has bits, parity) and restart file
been aborted. transfer.
1530 %s runtime error: Optional runtime error: Optional Part program Reset of current
text for KNB. text for KNB. error channel

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–71

No Error text Cause Correction Error class Reset mode


1531 %s runtime warning: Optional runtime warning: Optional Part program Reset of current
text for KNB. text for KNB. warning channel
1532 Wrong number of param- The entry in file ’startup’ Change the entry in file Interface warn- in the Info dia-
eters in file startup is not correct ’startup’. New start of the ing log with softkey
(NFSMOUNT host MMI ”Delete warn-
name:directory /mnt rw). ings”
1533 NFSMOUNT: Can’t ac- There is no access to the Change access rights of Interface warn- in the Info dia-
cess local directory. local directory the NFS the directory or the file. ing log with softkey
file system should be ”Delete warn-
linked with. Reasons: The ings”
local filename is not a
valid directory name. The
directory cannot be
created or the access
rights are not adjusted
correctly.
1534 NFSMOUNT ENONET: In the mounted file sys- Create the directory. Interface warn- in the Info dia-
NFS-Server cannot find tem the directory doesn’t ing log with softkey
directory. exist. ”Delete warn-
ings”
1535 NFSMOUNT: EPROTO Internal software error. No error recovery pos- Interface warn- in the Info dia-
protocol error (service not sible! ing log with softkey
available). ”Delete warn-
ings”
1536 NFSMOUNT EACCES: No rights to access the Change access rights of Interface warn- in the Info dia-
No access to target direc- directory or the file on the the directory or the file. ing log with softkey
tory. mounted file system. ”Delete warn-
ings”
1537 NFSMOUNT EBUSY: The entry in file ’startup’ Change the entry in file Interface warn- in the Info dia-
Mount already active on is not correct ’startup’. New start of the ing log with softkey
local directory (/mnt). MMI ”Delete warn-
ings”
1538 NFSMOUNT ENFILE: Too many open files. Close some files or part Interface warn- in the Info dia-
Too many open files. programs. ing log with softkey
”Delete warn-
ings”
1539 NFSMOUNT: Remote di- The name of the directory Change directory name. Interface warn- in the Info dia-
rectory name too short or is not allowed on the ing log with softkey
too long. mounted file system (i.e. ”Delete warn-
name length in DOS file ings”
system max. 8 charac-
ters).
1540 NFSMOUNT: No re- No network connection to Check the connection to Interface warn- in the Info dia-
sponse from NFS-Server. the server. Wrong host the network. Check the ing log with softkey
See TCP/IP connection name. Invalid host name. host name. ”Delete warn-
or internet number in /etc/ ings”
hosts.
1541 TCP/IP not initialized. Internal software error. No error recovery pos- Interface warn- in the Info dia-
sible! ing log with softkey
”Delete warn-
ings”
1542 TCP/IP: No memory in Internal software error. No error recovery pos- Interface warn- in the Info dia-
startup available. sible! ing log with softkey
”Delete warn-
ings”

1070 073 799-102 (02.05) GB


3–72 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1543 TCP/IP: cannot open file Internal software error. Change the entry in file Interface warn- in the Info dia-
/SYSTEMID. Contains ’startup’. New start of the ing log with softkey
host name (7 characters). MMI ”Delete warn-
ings”
1544 TCP/IP: Invalid host Only alphanumerical Change the entry in file Interface warn- in the Info dia-
name in /SYSTEMID. characters are allowed. ’startup’. New start of the ing log with softkey
See also /etc/hosts. The name must begin MMI ”Delete warn-
with an alpha character. ings”
1545 TCP/IP: Cannot set inter- Internal software error. No error recovery pos- Interface warn- in the Info dia-
net address of control. sible! ing log with softkey
”Delete warn-
ings”
1546 NFSMOUNT ENONET: No host name entry found Change the entry in file Interface warn- in the Info dia-
host name not in /etc/ in file, or host name is to ’startup’. New start of the ing log with softkey
hosts (host name max. 7 long MMI ”Delete warn-
character). ings”
1547 PC-Card-NMI : PC %x A system configuration is Insert again the PC card Serious system System Restart
SP %x PSR %x. active for which the whole and initiate a system error
root file system or a part startup with switch posi-
of it is on the PC card. tion S1 on ”6”.
The PC card has been re-
moved when the system
was running. The soft-
ware tried to access the
file system on the PC
card and detected that
there was no more PC
card. Now the file system
is probably corrupted.
1548 System memory class of The system memory The memory layout must Serious system System Restart
PXROS too small. class where the dynamic be changed. This can be error
memory and the internal done either by hardware
system objects of (more memory) or by
PXROS are managed is software exchange.
too small.
1549 No Spindle applied. There is no spindle ap- Correct MACODA param- Part program Reset of current
plied in MACODA eter. error channel
1550 Type must be integer. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1551 %s missing. Programming error at Correct programming er- Part program Reset of current
to CPL - command. Further ror. Select part program error channel
1557 information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1558 Type must be integer Programming error at Correct programming er- Part program Reset of current
constant. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1559 Nesting too deep. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1560 Incremental programming The function incremental If necessary update your Part program Reset of current
No error recovery pos- programming is locked for software version (>=V4). error channel
sible! in manual data in- software version V3 in
put at the moment. MDI.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–73

No Error text Cause Correction Error class Reset mode


1561 Fileserver function sig- During opening of a pro- No error recovery pos- Part program Reset of current
nals error %d of function gram or a subprogram sible! warning channel
unit %d. the indicated error oc-
curred in one of the fol-
lowing function units:
PXROS(-1), PXFILE(-2),
NCS server(-3) or file ser-
ver (-4).
1562 Permission denied File File isn’t executable. The access right must be Part program Reset of current
%s. set to execute (x). error channel
1563 Task-Id for task %s not Internal software error. No error recovery pos- Serious system System Restart
to found. sible! error
1571
1574 Permission denied File Programming error at Correct programming er- Part program Reset of current
%s. CPL - command. Further ror. Select part program warning channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1575 ”Drive Off” for axis-no. For a moving axis the in- Check the PLC-program. Part program Reset of current
%d! terface signal ”Drive Off” Continue is possible with error channel
was set. control reset.
1576 ”Drive Inhibit” for axis-no. For a moving axis the in- Check the PLC-program. Part program Reset of current
%d! terface signal ”Drive In- Continue is possible with error channel
hibit” has been set. control reset.
1578 Tool compensation values During switching to No error recovery pos- Part program Reset of current
could not be read. another external tool sible! Please report error error channel
compensation via G145, data and detailed soft-
G245 etc. the new com- ware version to the after
pensation value couldn’t sales service of the NC
be read correctly. manufacturer.
1579 System error in subsys- Internal software error. No error recovery pos- Minor system by mode
tem FMS (code lines %d sible! error change
%d).
1580 FMS: Cannot save object Internal software error. No error recovery pos- DNC error by mode
to dictionary. sible! change
1581
1582 FMS: Cannot save CRL. Internal software error. No error recovery pos- DNC error by mode
to sible! change
1585
1586 FMS: Cannot save bus Internal software error. No error recovery pos- DNC error by mode
to parameters. sible! change
1588
1589 Endless position mode is It is only possible to pro- Modify part program cor- Part program Reset of current
not switchable for axis gram endless axes (MA- responding to the MA- error channel
%d! CODA parameter CODA parameter or cor-
100300004 ”axis move- rect MACODA parameter.
ment type”) with G151
when MACODA parame-
ter 100300005 ”endless
axes positioning logic”
and 100300050 ”switch of
endless axis positioning
logic” are set in the right
way. Only the values 0, 1,
2 are possible (see
100300005).

1070 073 799-102 (02.05) GB


3–74 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1590 Invalid endless position It is only possible to pro- Modify part program cor- Part program Reset of current
mode for axis %d! gram endless axes (MA- responding to the MA- error channel
CODA parameter CODA parameter or cor-
100300004 ”axis move- rect MACODA parameter.
ment type”) with G151
when MACODA parame-
ter 100300005 ”endless
axes positioning logic”
and 100300050 ”switch of
endless axis positioning
logic” are set in the right
way. Only the values 0, 1,
2 are possible (see
100300005).
1591 Type of variable ”%s” in- Programming error at Correct programming er- Part program Reset of current
valid. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
1592 No feedrate programmed. No feed when tapping is Program feed before Part program Reset of current
active. threading. error channel
1593 Tapping retraction block After G32 tapping block After the first G32 block a Part program Reset of current
is missing. there is no following re- further G32 retraction error channel
traction block. block must be pro-
grammed.
1594 Drill axis switching: Pro- The following reasons are Program only one linear Part program Reset of current
gram a single linear feed possible: 1. Together with feed axis together with error channel
axis! G78 no axis was pro- G78.
grammed. 2. Together
with G78 more then one
axis was programmed. 3.
Together with G78 an
axis was programmed
which is not a linear feed
axis.
1595 Drill axis switching: Pro- For values programmed Program with G78 with Part program Reset of current
grammed axis value is together with G78 and the linear feed axis and only error channel
not allowed. linear feed axis are only the values +/-1, +/-13,
some definite values al- +/-21, +/-22, and +/-23.
lowed.
1596 No gear selected for Speed has been pro- Select the desired spindle Part program Reset of current
spindle 1! grammed for a spindle gear via interface. error channel
without a selected gear.
1597 There’s no spindle config- Although there’s no Please check your part Part program Reset of current
ured! spindle configured in MA- program or change your error channel
CODA, a spindle speed MACODA configuration.
has been programmed.
1598 There’s no gear selected A spindle speed has been Please select the wanted Part program Reset of current
for spindle 2! programmed for a spindle spindle gear via interface. error channel
without a selected gear.
1599 There’s no 2nd Spindle A spindle speed has been Check your part program Part program Reset of current
configured! programmed for spindle 2 or change your MACODA error channel
although there’s no sec- configuration.
ond spindle configured in
MACODA.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–75

No Error text Cause Correction Error class Reset mode


1600 There’s no geometry There is no geometry Choose the geometry Part program Reset of current
table activated! correction table activated. correction table by pro- error channel
The correction data is gramming G22 V ... in the
needed for tool com- referencing channel.
pensation.
1601 Debug-Trap (DBG-Trap) A hardware breakpoint on No error recovery pos- Serious system System Restart
occurred: PC %x SP %x the CPU has been trig- sible! error
TID %x PSR %x. gered. This is a serious
software error. Usually
the reason is that an ac-
cess to disallowed ad-
dress areas watched by
the breakpoint occurred.
1602 No zero offset table is se- A zero offset function has Please activate a zero Part program Reset of current
lected! been activated without offset table by program- error channel
first choosing a zero off- ming G22 V... in part pro-
set table. gram, MDI or in MA-
CODA (init string).
1603 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x.
1604 System error in the MMI Internal software error. No error recovery pos- Minor system System Restart
during processing of sible! error
MCo-data (code %d %d).
1605 Invalid value %x at ad- The logic monitoring the No error recovery pos- Serious system System Restart
dress %x. addresses 0x00 to 0x100 sible! error
has detected a write ac-
cess to this area. This
protected address area,
initialized with 0x00, has
been overwritten by faulty
system software.
1606 The Configuration-Data- The data structure ”layou- No error recovery pos- Serious system System Restart
Structure ”layoutinfo” is tinfo” is corrupt. This sible! error
corrupt. structure contains data
about the configuration of
hardware and about the
layout of memory classes
and of the file system.
There is a magic number
at the end of the struc-
ture. This magic number
is defective. The error
message can be gener-
ated at different locations
in the system.
1607 No memory for Software- The reservation of an in- No error recovery pos- Interface warn- in the Info dia-
PLC %d. ternal memory block has sible! ing log with softkey
failed. The number indi- ”Delete warn-
cates the memory on ings”
which the error occurred:
1=machine interface,
2=internal memory for
marker.

1070 073 799-102 (02.05) GB


3–76 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1608 Read error MP-Data %d. For the configuration of No error recovery pos- Interface warn- in the Info dia-
Soft-PLC data from MA- sible! ing log with softkey
CODA are needed. The ”Delete warn-
number indicates the MA- ings”
CODA parameter on
which the error occurred.
1=206000200,
2=206000201,
3=206000202,4=number
of channels,
5=206000002,
6=206000003, 7 to
15=301000010 to
301000090,
16=903000001, 17=num-
ber of axes and spindles,
18=206000005,
19=206000006,
20=206000007
1609 Ncs error from Software The communication be- No error recovery pos- Interface warn- in the Info dia-
PLC. tween Soft-PLC and Typ3 sible! ing log with softkey
has failed. The number ”Delete warn-
indicates the location ings”
where the error occurred:
1=Ncs connection to
Typ3 interrupted, 2=on
reading override data,
3=on reading axes data.
1610 Interpolator memory over- Internal software error. No error recovery pos- Part program Reset of current
flow. sible! error channel
1612 Diagnosis error %d. Internal software error. No error recovery pos- Serious system System Restart
sible! error
1613 Diagnosis error %d. Internal software error. No error recovery pos- Minor system in the Info dia-
sible! error log with softkey
”Delete warn-
ings”
1614 Slave axis %d is located A slave axis must not be Check your part program. Part program Reset of current
in the selected plane. part of the active plane. error channel
1615 Axis type of slave axis Axis type of master and Correct MACODA param- Part program Reset of current
%d not allowed. slave axis must consis- eter. error channel
tent.
1616 NC Function could not be Internal software error. No error recovery pos- Part program Reset of current
inserted. sible! error channel
1618 Master axis not allowed. The programmed master Check your part program. Part program Reset of current
axis does not belong to error channel
the active channel.
1619 Axis coupling: Master For starting axis coupling Check your part program. Part program Reset of current
axis is not programmed. a master axis must be error channel
programmed.
1621 Axis coupling: Slave axis A coupled axis must not Check your part program. Part program Reset of current
%d is member of another be a slave axis of another error channel
couple. couple.
1623 Axis coupling: Master A coupled axis must not Check your part program. Part program Reset of current
axis is member of another be a slave axis of another error channel
couple. couple.
1624 Couple factor %d not al- The absolute value of the Check your part program. Part program Reset of current
lowed. ratio is too small. error channel

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–77

No Error text Cause Correction Error class Reset mode


1625 Selected plane contains A slave axis must not be Check your part program. Part program Reset of current
slave axis %d. part of the active plane. error channel
1626 Couple lag for axis %d The difference of actual Check the axis’ dynamic. Part program Reset of current
exceeded. positions of two coupled If necessary adjust the error channel
axes exceeds the permis- values for monitoring in
sible maximum. The axis MACODA . Perform con-
which has a larger dis- trol reset. If necessary
tance to the common perform system or SER-
commanded position is COS startup.
indicated as the faulty
axis.
1627 NC-block overflow (re- NC blocks too long. Dur- Program shorter NC Part program Reset of current
to quested %d, maximum ing NC block recognition blocks. error channel
1628 %d characters). NC-internal syntax ele-
ments could be inserted
inserted.
Therefore the permissible
NC-block length may be
exceeded.
1631 Preceding block not avail- During punching or nib- No error recovery pos- Part program Reset of current
able. bling the preceding block sible! error channel
wasn’t available
(Sav_LookBack).
1632 NC Function could not be It wasn’t possible to insert No error recovery pos- Part program Reset of current
to inserted. an NC function during sible! error channel
1633 punching or nibbling
(Sav_InsertNCF).
1634 NC block couldn’t be in- During distance splitting No error recovery pos- Part program Reset of current
serted. of nibbling or punching it sible! error channel
was No error recovery
possible! to insert an NC
block (Acb_InsertLi-
nearBlk).
1635 Parameters for block No distance splitting was Program a distance split- Part program Reset of current
splitting are missing. programmed for a nibble ting. error channel
block.
1637 Cannot open directory Problems during access Try once more. Restart Part program Reset of current
”%s”. to data storage medium NC. Reduce net load. error channel
(for example timeout of
NFS).
1638 The actual negative travel This is an error which ac- No error recovery pos- Part program Reset of current
limit is smaller than MA- tually occurs only during sible! error channel
CODA value. system software integra-
tion.
1639 The actual positive travel This is an error which ac- No error recovery pos- Part program Reset of current
limit is larger than MA- tually occurs only during sible! error channel
CODA value. system software integra-
tion.
1640 The actual maximum axis This is an error which ac- No error recovery pos- Part program Reset of current
velocity is higher than tually occurs only during sible! error channel
MACODA parameter. system software integra-
tion.
1641 The actual rapid axis ve- This is an error which ac- No error recovery pos- Part program Reset of current
locity is higher than MA- tually occurs only during sible! error channel
CODA value. system software integra-
tion.

1070 073 799-102 (02.05) GB


3–78 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1642 The actual axis slope ac- This is an error which ac- No error recovery pos- Part program Reset of current
celeration is higher than tually occurs only during sible! error channel
MACODA parameter. system software integra-
tion.
1643 The actual axis step ve- This is an error which ac- No error recovery pos- Part program Reset of current
locity is higher than MA- tually occurs only during sible! error channel
CODA value. system software integra-
tion.
1644 The effective negative This is an error which ac- No error recovery pos- Part program Reset of current
travel limit is smaller than tually occurs only during sible! error channel
MACODA value. system software integra-
tion.
1645 The effective positive This is an error which ac- No error recovery pos- Part program Reset of current
travel limit is larger than tually occurs only during sible! error channel
MACODA value. system software integra-
tion.
1646 The effective maximum This is an error which ac- No error recovery pos- Part program Reset of current
axis velocity is higher tually occurs only during sible! error channel
than MACODA value. system software integra-
tion.
1647 The effective rapid axis This is an error which ac- No error recovery pos- Part program Reset of current
velocity is higher than tually occurs only during sible! error channel
MACODA value. system software integra-
tion.
1648 The effective axis slope This is an error which ac- No error recovery pos- Part program Reset of current
acceleration is higher tually occurs only during sible! error channel
than MACODA value. system software integra-
tion.
1649 The effective axis step This is an error which ac- No error recovery pos- Part program Reset of current
velocity is higher than tually occurs only during sible! error channel
MACODA value. system software integra-
tion.
1650 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, additional right paren- file. indicated lisp file. error channel
thesis in file %s line %d.
1651 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, misplaced dot in file file. indicated lisp file. error channel
%s line %d.
1652 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, invalid character ’%c’ file. indicated lisp file. error channel
in file %s line %d.
1653 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to ror, invalid dotted pair in file. indicated lisp file. error channel
1654 file %s line %d.
1655 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, invalid number in file file. indicated lisp file. error channel
%s line %d.
1656 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, unexpected end of file file. indicated lisp file. error channel
%d open, parenthesis in
file %s at line %d.
1657 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to ror, no or bad lisp function file. indicated lisp file. error channel
1658 in file %s line %d.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–79

No Error text Cause Correction Error class Reset mode


1659 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, can’t evaluate expres- file. indicated lisp file. error channel
sion in file %s line %d.
1660 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, bad formal argument file. indicated lisp file. error channel
list in file %s line %d.
1661 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, ”&optional” without file. indicated lisp file. error channel
parameter in file %s line
%d.
1662 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, ”&rest” without pa- file. indicated lisp file. error channel
rameter in file %s line
%d.
1663 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, wrong number of ar- file. indicated lisp file. error channel
guments to a lisp function
in file %s line %d.
1664 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, too few arguments in file. indicated lisp file. error channel
file %s line %d.
1665 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to ror, invalid argument in file. indicated lisp file. error channel
1667 file %s at line %d.
1668 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, too many arguments file. indicated lisp file. error channel
in file %s line %d.
1669 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, invalid lisp expression file. indicated lisp file. error channel
or unexpected end of
string in file %s line %d.
1670 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, invalid argument in file. indicated lisp file. error channel
file %s at line %d.
1671 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, wrong number of ar- file. indicated lisp file. error channel
guments to a lisp function
in file %s line %d.
1672 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, invalid argument in file. indicated lisp file. error channel
file %s at line %d.
1673 NC configuration: Too Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to little memory when read- file. indicated lisp file. error channel
1676 ing the file %s at line %d.
1677 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, invalid argument in file. indicated lisp file. error channel
file %s at line %d.
1678 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to ror, no or invalid list in file file. indicated lisp file. error channel
1681 %s at line %d.
1682 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to ror, invalid argument in file. indicated lisp file. error channel
1683 file %s at line %d.

1070 073 799-102 (02.05) GB


3–80 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1684 NC configuration: File not Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to open in file %s at line %d. file. indicated lisp file. error channel
1692
1693 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, invalid argument in file. indicated lisp file. error channel
file %s at line %d.
1694 NC configuration: The Faulty entry in the lisp Correct the syntax in the Part program Reset of current
NC-Word ”%s” is defined file. indicated lisp file. error channel
as ”%s” and as ”%s”.
1695 NC configuration: Too Faulty entry in the lisp Correct the syntax in the Part program Reset of current
little memory when read- file. indicated lisp file. error channel
ing the file %s at line %d.
1696 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, invalid argument in file. indicated lisp file. error channel
file %s at line %d.
1697 NC-Configuration: NC- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
Variable ”%s” has bad ar- file. indicated lisp file. error channel
gument type.
1698 Argument must be ”Non- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to Modal” or ”Modal” for NC- file. indicated lisp file. error channel
1699 Variable ”%s”.
1700 NC configuration: Syntax Faulty entry in the lisp Correct the syntax in the Part program Reset of current
error near MPP-Modifier file. indicated lisp file. error channel
”%s” at ”%s”.
1701 NC configuration: Too MAX_MPP_MODIFIER in Increase Part program Reset of current
many MPP-Modifiers %d file sav_ncw.h too small. MAX_MPP_MODIFIER in error channel
(max. %d). sav_ncw.h.
1702 NC configuration: NC Faulty entry in the lisp Correct the syntax in the Part program Reset of current
function for MPP %d,%d file. indicated lisp file. error channel
multiply defined.
1703 NC configuration: Un- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
known syntax modifier file. indicated lisp file. error channel
”%s”.
1704 NC configuration: NC Faulty entry in the lisp Correct the syntax in the Part program Reset of current
variable ”%s” hides NC- file. indicated lisp file. error channel
Function, therefore
”Modal” definition is re-
quired.
1705 NC configuration: NC Faulty entry in the lisp Correct the syntax in the Part program Reset of current
function ”%s” is hidden by file. indicated lisp file. error channel
a ”modal” NC variable,
therefore the NC-Variable
must be defined ”NonMo-
dal”.
1706 NC configuration: NC Faulty entry in the lisp Correct the syntax in the Part program Reset of current
function ”%s” is multiply file. indicated lisp file. error channel
defined with the same
syntax.
1707 NC configuration: Multiple Faulty entry in the lisp Correct the syntax in the Part program Reset of current
definition of ”%s” not per- file. indicated lisp file. error channel
mitted.
1708 NC configuration: NC Faulty entry in the lisp Correct the syntax in the Part program Reset of current
function ”%s” not defined. file. indicated lisp file. error channel
1709 NC configuration: Un- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
known NC variable ”%s”. file. indicated lisp file. error channel

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–81

No Error text Cause Correction Error class Reset mode


1710 NC configuration: NC Faulty entry in the lisp Correct the syntax in the Part program Reset of current
variable ”%s” has differ- file. indicated lisp file. error channel
ent types or sizes in the
subsystems.
1711 NC configuration: Local Faulty entry in the lisp Correct the syntax in the Part program Reset of current
memory overflow, re- file. indicated lisp file. error channel
quested are %d (max.
%d)bytes by the NC func-
tion ”%s”.
1712 NC configuration: NC- There is no subsystem Define the NC variable Part program Reset of current
Variable ”%s” is not de- where the NC variable with NCDefGlob, NCDef- error channel
fined in any subsystem. was defined globally. Mod or NCDefLoc in C
source code of a subsys-
tem globally.
1713 NC configuration: Modal The size of all data de- Reduce number and size Part program Reset of current
data size overflow, re- fined with NCDefMod ex- of modal data. error channel
quired %d bytes, max. ceeds the data storage
%d. capacity of a modal data
block.
1714 NC configuration: Global The size of all data de- Reduce number and size Part program Reset of current
data size overflow, re- fined with NCDefGlob ex- of global data. error channel
quired %d bytes, max. ceeds the data storage
%d. capacity of a global data
block.
1715 NC configuration: Unex- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
pected end of file without file. indicated lisp file. error channel
(exit) in file %s at line %d.
1716 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, unexpected end of file file. indicated lisp file. error channel
%d open, parenthesis in
file %s at line %d.
1717 Programmed torque It was internally at- Program a torque limit Part program Reset of current
value is bigger than tempted to assign a within the valid input error channel
500%. torque limit greater than range (0-500%).
500%. Admissible are
values in the range
0-500%.
1718 Programmed maximum It was internally at- Program a torque limit Part program Reset of current
torque is smaller than tempted to assign a within the valid input error channel
0%. torque limit greater than range (0-500%).
500%. Admissible are
values in the range
0-500%.
1736 Maximum motion dis- An overflow occurred Please check the pro- Part program in the Info dia-
tance exceeded while when calculating the pro- grammed thread parame- error log with softkey
tapping (relation grammed thread. The ters in part program. ”Delete warn-
length:height). programmed thread pa- ings”
rameters are not plausi-
ble.
1737 Wrong interpolation type Punch block without ac- Program G408, if neces- Part program in the Info dia-
to for punching. tive G408 or G608. sary with shape order 1. error log with softkey
1738 ”Delete warn-
ings”
1739 It is No error recovery Internal software error. No error recovery pos- Part program in the Info dia-
possible! to create an in- sible! error log with softkey
sert block for axis cou- ”Delete warn-
pling. ings”

1070 073 799-102 (02.05) GB


3–82 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1740 No memory for local data Internal software error. No error recovery pos- Part program in the Info dia-
of axis coupling. sible! error log with softkey
”Delete warn-
ings”
1741 Invalid syntax for auxiliary The list of auxiliary func- Correct list. Part program in the Info dia-
function ”%s”, tail ”%s” ig- tion names is partially in- warning log with softkey
nored. correct. ”Delete warn-
ings”
1742 Start of NCB-TCP Inter- This error occurs, if dur- Please check the connec- Serious system System Restart
face aborted. Detailed ing startup the system tion between the control error
code %d (%s). doesn’t recognize the and the passive operating
passive panel and the panel.
software configuration is
not able to work with a
PC panel. This error also
occurs if the system
needs too much memory
or system information is
overwritten.
1743 Runtime error in NCB- The control has detected This is an internal error, Interface error System Restart
TCP interface. Detailed an error in the RAM file which should only occur
code %d (%s). system. RAM file system during software develop-
will be regenerated at ment and software in-
next startup. tegration. Please contact
your NC manufacturer.
1744 Assertion error in NCS- The control had detected This is an internal error, Interface error System Restart
TCP interface. Detailed a wrong data state of the which should only occur
code %d (%s). NCS-TCP interface. This during software develop-
error can occur if data of ment and software in-
NC are overwritten or if a tegration. Please contact
protocol error between your NC manufacturer.
NC and operating com-
puter occurred.
1745 Data lost in RAM file sys- The control has detected This is an internal error, Serious system System Restart
tem. FSCK error 0x%x. an error in the RAM file which should only occur error
system. RAM file system during software develop-
will be regenerated at ment and software in-
next startup. tegration. Please contact
your NC manufacturer.
1746 Data lost in RAM file sys- The control has detected This is an internal error, Serious system System Restart
tem. Startup error 0x%x. an error in the RAM file which should only occur error
system. RAM file system during software develop-
will be regenerated at ment and software in-
next startup. tegration. Please contact
your NC manufacturer.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–83

No Error text Cause Correction Error class Reset mode


1747 File system error: direc- File system of the direc- It is possible to read the Minor system System Restart
tory user FEPROM Sta- tory user FEPROM (/usr- data of the corrupted user error
tus 0x%x. fep) is destroyed. This er- FEPROM in the directory
ror occurs if the control ”/usrfepbk”. Attention:
has been switched off The contents of the file
during data storage to the might be destroyed. It is
user FEPROM. possible to save the files
with the help of the serial
interface. If the user FE-
PROM was completely
destroyed the directory
”/usrfepbk” is not created.
The user FEPROM must
be initialized: Switch S1
to position ”7” and initiate
a system startup. After
that, the switch must be
turned back to the pre-
vious position.
1748 File system error: Direc- The File system of direc- No error recovery pos- Serious system System Restart
tory FEPROM Status tory FEPROM (/feprom) sible! error
0x%x. is destroyed. Control is
no longer in working or-
der.
1749 The values of the external During switching to No error recovery pos- Part program Reset of current
zero offset could not be another external zero off- sible! error channel
read. set via G160, G260 etc.
the new offset value
couldn’t be read correctly.
1750 Line length overflow, %d The line is longer than the Shorten line. Part program Reset of current
needed, %d permitted. internal line buffer. This error channel
problem can be evoked if
line elements are ex-
panded during part pro-
gram runtime.
1751 Watchdog PLC activated. The time between two Check if an endless loop Minor system System Restart
PLC calls is too long. is programmed in the error
PLC program.
1752 Job list overflow %d Too many modal and Program fewer NC func- Part program Reset of current
needed, %d possible. non-modal NC codes (G tions in the NC block. error channel
and M codes) are pro-
grammed in one NC
block.

1070 073 799-102 (02.05) GB


3–84 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1753 MACODA-Parameter The MACODA parameter Check the adjustment of Part program Reset of current
<109000021 Unit ... value is outside its per- the MACODA parameter. warning channel
Tables> has illegal value: missible range. This may If an inadmissible value is
mm assumed. occur if the configuration found, it must be cor-
file (mcadbpar.txt) in the rected. The configuration
user FEPROM or in the file ”mcadbpar.txt” stored
root directory has been in the user FEPROM, in
changed illegally. Instead the root directory or exter-
of the illegal value a de- nally must also be
fault value defined by checked. Files containing
BOSCH or the OEM is a inadmissible value
used. should be deleted. De-
leted files can be created
again by means of the
function ”save data set”
and ”save data set in FE-
PROM” within the MACO-
DA-Dialogue.
1754 Not enough memory to There was an attempt to Check if it is possible to Part program Reset of current
insert a NC function. insert a nonexistent NC modify your part program. error channel
function or there wasn’t If not, inform the after
enough memory to insert sales service of the NC
an NC function. manufacturer.
1755 Acceleration value 0 for Error in part program. Program an acceleration Part program Reset of current
axis %d is not allowed. which is greater then error channel
zero.
1756 SERCOS service channel At least two simultaneous No error recovery pos- Part program Reset of current
is locked. calls to the service chan- sible. Please call your error channel
nel of an axis occurred. Bosch service.
1757 Fatal error profibus DP Error without control from The DP-master software Interface error System Restart
master. DP master. must be restarted. Initiate
a system startup.
1758 Profibus DP master has Short circuit on bus. Check the bus wires for a Interface error System Restart
no bus connection. short circuit.
1759 Data exchange with DP The DP-Slave didn’t have Check of the PDP wiring Interface error System Restart
slave disturbed (DP slave any data traffic longer and the Slave causing
address %d). than 10 data interchange faults.
loops.
1760 DP slave unavailable (DP No data traffic to the DP- Check of the PDP wiring Interface error System Restart
slave address %d). Slave and the Slave causing
faults.
1761 No response of DP-Mas- DP master has waited No error recovery pos- Interface error System Restart
ter interrupt. 500ms since last interrupt sible!
and hasn’t got any reply.
1762 DP master doesn’t know DP master doesn’t know No error recovery pos- Interface error System Restart
the required service. the service required by sible!
the slave.
1763 Data leak in permanent Internal software error. No error recovery pos- Minor system in the Info dia-
memory of the software sible! Initiate a system error log with softkey
PLC. startup with switch posi- ”Delete warn-
tion S1 on ”1”. ings”
1764 Programmed acceleration Programmed acceleration Program a value less Part program Reset of current
is too large for axis %d! must be less than the than the corresponding error channel
MACODA parameter MACODA value.
value.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–85

No Error text Cause Correction Error class Reset mode


1765 Illegal operation in inter- Internal software error. No error recovery pos- Serious system System Restart
rupt with number %x at sible! error
address %x.
1766 Illegal operation in task Internal software error. No error recovery pos- Serious system Reset of current
with Id %x at address %x. sible! error channel
1767 Illegal operation in task Internal software error. No error recovery pos- Serious system System Restart
with Id %x at address %x. sible! error
1768 Task control block of task Internal software error. No error recovery pos- Serious system System Restart
to with Id %x is defective. sible! error
1777
1778 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x.
1779 Overflow trap in task %x Internal software error. No error recovery pos- Serious system System Restart
at address %x PSR: %x sible! error
SP0: %x SP1: %x FP:
%x.
1780 Overflow trap in interrupt Internal software error. No error recovery pos- Serious system System Restart
to with no %x at address %x sible! error
1782 PSR: %x SP0: %x SP1:
%x FP: %x.
1783 Error in trap handling. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
1800
1801 Trap %x at address: %x Internal software error. No error recovery pos- System Restart
PSR: %x SP0: %x SP1: sible!
%x FP: %x.
1802 Bound trap in task %x at Internal software error. No error recovery pos- Serious system System Restart
to address %x PSR: %x sible! error
1805 SP0: %x SP1: %x FP:
%x.
1806 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x.
1807 Double fault trap in task Internal software error. No error recovery pos- Serious system System Restart
%x at address %x PSR: sible! error
%x SP0: %x SP1: %x FP:
%x.
1808 Double fault trap in inter- Internal software error. No error recovery pos- Serious system System Restart
to rupt with no. %x at ad- sible! error
1810 dress %x PSR: %x SP0:
%x SP1: %x FP: %x.
1811 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x error: %x.
1812 Invalid TSS trap in task Internal software error. No error recovery pos- Serious system System Restart
%x at address %x PSR: sible! error
%x SP0: %x SP1: %x FP:
%x error: %x.
1813 Invalid TSS trap in inter- Internal software error. No error recovery pos- Serious system System Restart
to rupt with no. %x at ad- sible! error
1815 dress %x PSR: %x SP0:
%x SP1: %x FP: %x er-
ror: %x.

1070 073 799-102 (02.05) GB


3–86 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1816 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x error: %x.
1817 Segment not present trap Internal software error. No error recovery pos- Serious system System Restart
in task %x at address %x sible! error
PSR: %x SP0: %x SP1:
%x FP: %x error: %x.
1818 Segment not present trap Internal software error. No error recovery pos- Serious system System Restart
to in interrupt with no. %x at sible! error
1820 address %x PSR: %x
SP0: %x SP1: %x FP: %x
error: %x.
1821 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x error: %x.
1822 Stack fault trap in task %x Internal software error. No error recovery pos- Serious system System Restart
to at address %x PSR: %x sible! error
1825 SP0: %x SP1: %x FP: %x
error: %x.
1826 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x error: %x.
1827 General protection fault Internal software error. No error recovery pos- Serious system System Restart
to trap in task %x at address sible! error
1830 %x PSR: %x SP0: %x
SP1: %x FP: %x error:
%x.
1831 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x error: %x.
1832 Page fault trap in task %x Internal software error. No error recovery pos- Serious system System Restart
at address %x PSR: %x sible! error
SP0: %x SP1: %x FP: %x
error: %x.
1833 Page fault trap in interrupt Internal software error. No error recovery pos- Serious system System Restart
to with no. %x at address sible! error
1835 %x PSR: %x SP0: %x
SP1: %x FP: %x error:
%x.
1836 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x.
1837 Alignment check trap in Internal software error. No error recovery pos- Serious system System Restart
task %x at address %x sible! error
PSR: %x SP0: %x SP1:
%x FP: %x.
1838 Alignment check trap in Internal software error. No error recovery pos- Serious system System Restart
to interrupt with no. %x at sible! error
1840 address %x PSR: %x
SP0: %x SP1: %x FP:
%x.
1841 Trap %x at address: %x Internal software error. No error recovery pos- Serious system System Restart
PSR: %x SP0: %x SP1: sible! error
%x FP: %x.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–87

No Error text Cause Correction Error class Reset mode


1842 Reserved trap 9,15,18 .. Internal software error. No error recovery pos- Serious system System Restart
to 31 in task %x at address sible! error
1845 %x PSR: %x SP0: %x
SP1: %x FP: %x.
1846 Programming of an axis No axis programmed for Program the concerning Part program Reset of current
for measuring probe func- measuring probe func- axis with the syntax error channel
tion missing! tion. ”MpiAxis <Index>”.
1847 Wrong axis index for lin- The indicated axis Program the index of a Part program Reset of current
ear modulo axis zeroing. doesn’t exist or the axis configured axis of type error channel
type is not ”linear mo- ”linear modulo”.
dulo”.
1848 Linear modulo axis: The It is only allowed to pro- Program a value less Part program Reset of current
absolute value of the pro- gram values for linear than the modulo value of error channel
grammed value is greater modulo axes if the abso- the axis.
than the modulo value. lute value is less than the
modulo value.
1849 Block controller cannot in- The block preparation No error recovery pos- Part program Reset of current
sert transition circular probably doesn’t have sible! error channel
block! sufficient memory.
1850 The geometry for the Program a smaller transi- Part program Reset of current
transition circular block tion radius. The pro- error channel
does not exist. grammed circle radius
must be greater than the
transition radius.
1851 Wrong axis index for The programmed axis is Program the index of a Part program Reset of current
function measure probe not configured. configured axis. error channel
input.
1852 A too large transition cir- The transition circular arc Program a smaller transi- Part program Reset of current
cular arc is programmed. cannot be determined tion radius. error channel
geometrically.
1853 No memory for NC block Internal software error. No error recovery pos- Part program Reset of current
insertion, NC-Function: sible! error channel
rotary axis release
1854 Insufficient memory for Internal software error. No error recovery pos- Part program Reset of current
private data, NC-Func- sible! error channel
tion: rotary axis release.
1855 Insufficient memory for lo- Internal software error. No error recovery pos- Part program Reset of current
cal data, NC-Function: sible! error channel
rotary axis release.
1856 Drive error for coupled The drives of one couple Check the drives’ states Servo loop or Reset of current
axis %d. are in different states. in digital interface and drive fault channel
check the drives’ signals
in PLC program.
1857 Ready%d failed. The ready signal failed, The PLC user program Hardware error System Restart
to because of a digital doesn’t start with switch
1858 watchdog problem position ”1” on the SM
module.

1070 073 799-102 (02.05) GB


3–88 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1859 The digital watchdog noti- The digital watchdog No error recovery pos- Hardware error System Restart
fies a watchdog error. watches over the SER- sible!
COS interrupt, and the
analog watchdog watches
over the system time in-
terrupt of the real-time
operating system. If one
of these watchdogs de-
tects an error, the system
is crashed or overloaded
with interrupt handling or
interrupts were disabled.
The reason is mostly a
software error. The ana-
log watchdog must be
triggered at least every
50ms, the digital watch-
dog at least every two
SERCOS cycles.
1860 The analog watchdog no- The digital watchdog No error recovery pos- Hardware error System Restart
tifies a watchdog error. watches over the SER- sible!
COS interrupt, and the
analog watchdog watches
over the system time in-
terrupt of the real-time
operating system. If one
of these watchdogs de-
tects an error, the system
is crashed or overloaded
with interrupt handling or
interrupts were disabled.
The reason is mostly a
software error. The ana-
log watchdog must be
triggered at least every
50ms, the digital watch-
dog at least every two
SERCOS cycles.
1861 The SERCOS chip noti- Serious software error: No error recovery pos- Hardware error System Restart
fies an access conflict in The buffers in the dual- sible!
the dual port RAM. port RAM of the SERCOS
chip are read or written
by the CPU while the
buffers are occupied by
the SERCOS controller it-
self. The cause is a de-
sign error in SERCOS or
interpolator interrupt.
1862 Area is not program- According to MACODA, Modify the part program Part program Reset of current
mable. the programmed area or change the definition of error channel
cannot be modified in a the indicated area in MA-
part program. CODA parameters.
1863 Invalid area number. No more than 10 monitor- Program an area with an Part program Reset of current
ing areas can be ad- index at most ten. error channel
justed.
1864 Undefined Area. The programmed area is Define the programmed Part program Reset of current
not defined in MACODA area in the MACODA pa- error channel
parameters. rameters.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–89

No Error text Cause Correction Error class Reset mode


1865 Invalid area number. No more than 10 monitor- Program an area with an Part program Reset of current
to ing areas can be ad- index at most ten. error channel
1866 justed.
1868 Error of PDP-Configura- Error in configuration file. The configuration file Interface error System Restart
tion %d. must be checked and
created again if neces-
sary.
1869 Permanent CPL variable During startup several No error recovery pos- Minor system in the Info dia-
”%s” not installed. Me- permanent CPL variables sible! error log with softkey
mory full. (system variables) are ”Delete warn-
created by the subsystem ings”
Opi. But there is no more
memory available.
1870 Permanent CPL variable CPL variable was multiply No error recovery pos- Minor system in the Info dia-
”%s” not installed. Wrong defined with different sible! error log with softkey
data type. types. ”Delete warn-
ings”
1871 Type of axis shape not The programmed shape Check your part program. Part program Reset of current
defined. type doesn’t exist. error channel
1872 Order of axis shape not The programmed shape Check your part program. Part program Reset of current
allowed. order is larger than al- error channel
lowed.
1873 SPLC server error from An error occurred during No error recovery pos- Serious system System Restart
Ncs_Open. the initialization of the sible! error
Soft-PLC Aps server.
1875 SPLC server error during The Aps server needs a No error recovery pos- Serious system System Restart
creating the mailbox. mail box to receive mes- sible! error
sages. The initialization of
the mail box failed.
1876 SPLC server error during During the transfer of the No error recovery pos- Serious system System Restart
initialization of SF3 ser- service list to the Aps ser- sible! error
vices. ver an error occurred (
Services for Soft-PLC
data access)
1877 SPLC server error during An error occurred during No error recovery pos- Serious system System Restart
initialization of APS ser- the transfer of the service sible! error
vices. list to the Aps server.
(Services for logic ana-
lyzer)
1878 SPLC server error during The server initialization No error recovery pos- Serious system System Restart
reading MACODA param- failed due to a MACODA sible! error
eter 206000003. read error.
1879 SPLC server error: No For recording data the No error recovery pos- Part program System Restart
memory for LA. logic analyzer needs an sible! error
internal buffer. The buffer
creation failed.
1880 SPLC server error during An error occurred during No error recovery pos- Serious system System Restart
reading MACODA param- detection of the number sible! error
eter 301000010. of bit coded auxiliary
functions in Aps server in-
itialization.
1882 SPLC server SendRes- An error occurred during No error recovery pos- Serious system System Restart
ponse from %s. transmission of the re- sible! error
sponse to the message
”ApsGetData”.

1070 073 799-102 (02.05) GB


3–90 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1883 SPLC server SendRes- An error occurred during No error recovery pos- Core system in the Info dia-
ponse from MzaDataRe- the transmission of the sible! warning log with softkey
quest. response to the message ”Delete warn-
”MzaData”. ings”
1884 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse from ApsTrans- transmission of the re- sible! error
Feld. sponse to the message
”ApsTransferfeld”.
1885 SPLC server SendRes- An error occurred during No error recovery pos- Core system in the Info dia-
ponse from ApsSetData. transmission of the re- sible! warning log with softkey
sponse to the message ”Delete warn-
”ApsSetData”. ings”
1886 SPLC server error buffer An error occurred during No error recovery pos- Minor system System Restart
requisition in function %s creation of a local con- sible! error
. tainer for the message
”ApsGetData”.
1887 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse from ApsHifuQuit- transmission of the re- sible! error
tierung sponse to the acknowl-
edgment auxiliary func-
tions.
1888 SPLC server SendRes- Recording in the logic Wait until the previous re- Minor system System Restart
ponse LA already active analyzer was started cording is finished. error
from StartLaRecording. again although an old re-
cording was still active.
1889 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA Triggerinit from transmission of the trig- sible! error
StartLaRecording. ger mode to the logic
analyzer.
1890 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse Start OK from transmission of the re- sible! error
StartLaRecording. sponse to the logic ana-
lyzer start signal.
1891 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA start parameter transmission of the re- sible! error
from StartLaRecording. sponse to the logic ana-
lyzer stop signal.
1892 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA not active from transmission of the re- sible! error
AboLaRecording. sponse to the logic ana-
lyzer ”WAITING”.
1893 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA invalid ID from transmission of the re- sible! error
AboLaRecording. sponse to a wrong logic
analyzer ID.
1894 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA valid ID from transmission of the re- sible! error
AboLaRecording. sponse to a wrong logic
analyzer ID.
1895 SPLC server SendRe- An error occurred during No error recovery pos- Minor system System Restart
quest LA invalid ID from transmission of the re- sible! error
RequestlaNewState. sponse to reading new
logic analyzer state.
1896 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA valid ID from transmission of the re- sible! error
RequestlaNewState. sponse to a valid logic
analyzer state.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–91

No Error text Cause Correction Error class Reset mode


1897 SPLC-Server SendRe- An error occurred during No error recovery pos- Minor system System Restart
quest LA end of recording transmission of the re- sible! error
from RequestlaNewState. sponse to a valid logic
analyzer state at the end
of recording.
1898 SPLC server SendRes- Storing the message of No error recovery pos- Minor system System Restart
ponse LA recording on the logic analyzer state in sible! error
from RequestlaNewStat. a local container failed.
1899 SPLC server SendRes- Storing the message of No error recovery pos- Minor system System Restart
ponse LA invalid ID from the logic analyzer state at sible! error
RequestLaEndState. the end of recording
failed.
1900 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse end of recording transmission of recorded sible! error
from RequestLaEndState. data from the logic ana-
lyzer to the client.
1901 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA recording on transmission of the re- sible! error
from LaReqTransBuff. sponse to the message
”Transferbuffer” in the
case where the logic ana-
lyzer recording is still ac-
tive.
1902 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA illegal offset transmission of the re- sible! error
from LaReqTransBuff. sponse to the message
”Transferbuffer” in the
case where a wrong off-
set was transmitted.
1903 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA illegal size from transmission of the re- sible! error
LaReqTransBuff. sponse to the message
”Transferbuffer” in the
case where a wrong num-
ber of data was de-
manded.
1904 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA data from La- transmission of the re- sible! error
ReqTransBuff. sponse to the message
”Transferbuffer” .
1905 SPLC server SendRes- An error occurred during No error recovery pos- Minor system System Restart
ponse LA end of record- transmission of the re- sible! error
ing from Aps_La_Auf- sponse to the message
zeich. ”recording stop”.
1907 Wrong initialization of the Internal software error. No error recovery pos- Minor system System Restart
CPL server. sible! error
1908 NCB error in CPL server. Internal software error. No error recovery pos- Minor system System Restart
sible! error
1909 Dead range %d inhibited. The programmed motion Please modify your part Part program Reset of current
to reached an inhibited program. error channel
1911 area.
1912 Outside of working range The programmed motion Please modify your part Part program Reset of current
%d. would exceed the indi- program. error channel
cated area

1070 073 799-102 (02.05) GB


3–92 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1913 Drive operation mode Examine whether the Switch on the drive re- Part program Reset of current
switch No error recovery drives have been re- leases! error channel
possible!! leased. Without release it
is No error recovery pos-
sible! to change NC
mode.
1914 MACODA parameter The indicated MACODA Please perform a control Core system System Restart
501050100 to 501050180 parameters cannot be ac- reset, otherwise, the MA- warning
can only be adopted with tivated by Control Reset CODA parameters might
control startup. have an inconsistent sta-
tus.
1915 No information about file The editor normally Minor system System Restart
system available (RAM/ doesn’t have any informa- error
FEPROM). Save file to tion about the source and
RAM. the destination directory
of the opened file. Before
storing the file it must be
assured that the destina-
tion directory isn’t FE-
PROM. If it isn’t possible
to get this information by
a function call, the file
must be stored in RAM
file system because of
safety principles.
1916 Internal memory refer- Memory allocation error No error recovery pos- Part program Reset of current
to ence error in block prepa- within block preparation. sible! error channel
1925 ration.
1926 Local data overflow in Memory allocation error No error recovery pos- Part program Reset of current
block preparation, %d by- within block preparation. sible! error channel
tes maximum, %d bytes
requested.
1927 The block preparation is Within block preparation The maximum number of Part program Reset of current
to limited to %d NC block(s), a look-ahead is neces- blocks that can be pre- error channel
1928 even though further look sary which needs more pared must be increased
ahead is requested. NC blocks than the maxi- by an NC program in-
mum of prepared NC struction.
blocks permits.
1929 BDS-Error %d. Internal software error. No error recovery pos- Serious system System Restart
to sible! error
1932
1933 Error during input of %s. Activation of the file, No error recovery pos- Part program Reset of current
named in error message sible. Please call your error channel
with Code G22 ID... Bosch service.
failed.
1934 Active contour shift not al- The programmed contour Deactivate the contour Part program Reset of current
lowed with switch of in- offset refers to the acti- offset function before error channel
clined plane. vated working coordinate changing the coordinate
system. Therefore it must system.
be switched off before
changing the working
coordinate system.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–93

No Error text Cause Correction Error class Reset mode


1935 Active scaling function The scaling function re- Deactivate the scaling Part program Reset of current
not allowed with switch of fers to the active pro- function well before error channel
inclined plane. gramming coordinate sys- changing the inclined
tem. Therefore scaling plane.
must be switched off be-
fore changing an inclined
plane.
1936 Cutter compensation not The cutter compensation Switch off the cutter com- Part program Reset of current
allowed with switch of in- refers to actual plane. pensation by program- error channel
clined plane. Therefore cutter com- ming G40 before switch-
pensation must be ing the inclined plane.
switched off before
changing the inclined
plane.
1937 Zero offset and correction The use of the zero offset You will find more infor- Part program Reset of current
of workpiece position not function is not allowed mation in your DIN pro- error channel
allowed with inclined while an inclined plane is gramming instructions
plane function. active. (chapter about function to
define coordinate system
transformations) .
1938 Invalid axis index pro- The programmed oscilla- Please use an oscillation Part program Reset of current
grammed! tion axis is not a member axis which is member of error channel
of the channel. the specified channel (os-
cillation axis is pro-
grammed by its physical
axis index).
1939 Upper reversing point ex- Upper reversing point vio- Adjust either the pro- Part program Reset of current
ceeds software travel lim- lates the software travel grammed upper reversing error channel
its! limits defined in MA- point in part program or
CODA. the software travel limits
in MACODA.
1940 No upper reversing point For definition of an os- Please program the up- Part program Reset of current
programmed! cillation movement the per reversing point (syn- error channel
upper reversing point is tax URP ...) together with
necessary. G350 in the same NC
block.
1941 Lower reversing point ex- The lower reversing point Please change the lower Part program Reset of current
ceeds software travel lim- of the oscillation function reversing point in your error channel
its! violates the software part program or the soft-
travel limits fixed in MA- ware travel limits in MA-
CODA. CODA.
1942 No lower reversing point For definition of the os- Please program the lower Part program Reset of current
programmed! cillation movement the reversing point (syntax error channel
lower reversing point is LRP) together with G350
necessary. in the same NC block.
1943 Lower reversing point For logical reasons the Please check the pro- Part program Reset of current
must be smaller than the lower reversing point LRP gramming of the oscilla- error channel
upper reversing point! must be smaller than the tion movement in NC
upper reversing point block G350 ... .
(URP).
1944 Neither feedrate nor os- For an oscillation move- Please program F or OF Part program Reset of current
cillation frequency pro- ment either the feedrate F together with the other error channel
grammed! or the oscillation fre- oscillation parameters in
quency must be pro- NC block G350 ... .
grammed.

1070 073 799-102 (02.05) GB


3–94 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1945 No axis index pro- Oscillation axis is missing The oscillation axis must Part program Reset of current
grammed. within definition of an os- be programmed together error channel
cillation movement. with G350 by specifying
its physical axis index
with syntax OscAxis.
1946 Programming of the os- While an axis is defined Delete the explicit pro- Part program Reset of current
cillation axis address is as an oscillation axis it’s gramming of the oscilla- error channel
not allowed. not allowed to program its tion axis or switch off the
regular address. oscillation, e.g. by pro-
gramming G1.
1947 Oscillation axis data not An oscillation movement Before starting the os- Part program Reset of current
initialized. has been programmed cillation movement, initial- error channel
(G301) while the oscilla- ize the oscillation by pro-
tion parameters are not gramming G350 OscAxis
specified. ... URP ... LRP ... F... / OF
... .
1948 Insert block could not be The internal memory is If necessary reduce the Part program Reset of current
to generated! exhausted. The memory number of NC blocks for error channel
1951 needed for function G301 block preparation in MA-
is not available by the CODA or ask for BOSCH
system. service.
1952 BDS error %d. Subsystem BDS is in a No error recovery pos- Serious system System Restart
to state in which an abort is sible! error
1955 necessary.
1957 System error in customer Internal software error. No error recovery pos- Minor system System Restart
server (code lines %d sible! error
%d).
1958 Customer server: Error Internal software error. No error recovery pos- Serious system System Restart
%d during sending NCS sible! error
response.
1959 Customer server: Error in Internal software error. No error recovery pos- Minor system System Restart
”Ncs_CsrCustomerRe- sible! error
quest(_A)”. Missing cus-
tomer specific request
handler function.
1960 Local data for NC-func- Internal software error. No error recovery pos- Part program Reset of current
tion not available. sible! error channel
1961 NC Function could not be Internal software error. No error recovery pos- Part program Reset of current
to inserted. sible! error channel
1964
1965 Internal MMI error (%d Internal software error. No error recovery pos- MMI error in the Info dia-
%d) - further operation sible! log with softkey
possible. ”Delete warn-
ings”
1966 Internal MMI error (%d Internal software error. No error recovery pos- MMI error in the Info dia-
%d) - further operation sible! log with softkey
possible. ”Delete warn-
ings”

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–95

No Error text Cause Correction Error class Reset mode


1967 TCP/IP: Internet address The internet address is Adjust the internet ad- Interface warn- in the Info dia-
in file ”hosts” and local in- stored at two places: 1. In dress either by means of ing log with softkey
ternet address in EE- the serial EEPROM of the the tools ”tcpsetup” or ”Delete warn-
PROM of the SNCI are SNCI (will be used by the ”T3Config” or adapt the ings”
different. monitor when loading the address in the serial EE-
software). 2. In the file PROM to the address
”hosts”, which will be read found in the file ”hosts”
by TCP/IP during system with a debugger monitor
startup. The address in command or adapt the
”hosts” will be found by address in the file ”hosts”
using the system name with the editor to the ad-
from ”SYSTEMID”. When dress stored in the serial
the internet address is set EEPROM.
by the tool ”tcpsetup” it
will be stored in EEPROM
and available for TCP/IP,
but it is not yet stored in
the file ”hosts”. The Ad-
dress must be inserted in
the file ”hosts” either by
editing the file or by using
the tool”t3config” (that will
create a file named
”hosts” in the NC). The
addresses may be differ-
ent if only the files ”hosts”
or only the EEPROM is
changed.
1968 Serial port for LSV2-DNC Cannot activate The serial port is used by DNC error by mode
unavailable. LSV2-DNC because no an other application and change
serial port is available. may not be used by
LSV2-DNC.
1969 Axis %d: Wrong axis Wrong axis operation Adjust another axis op- Part program Reset of current
mode active. mode by interface input. eration mode on the axis error channel
interface input.
1970 Axis %d is used by An asynchronous axis Stop the asynchronous Part program Reset of current
another channel. started by another chan- axis with channel control error channel
nel is still moving. reset.
1971 Synchronous axis of A program has been se- Wait until the axes have Part program Reset of current
channel %d are not en- lected during jog motion stopped or abort with error channel
abled. or reference motion. channel control reset.
1972 Internal MMI error (%d Internal software error. No error recovery pos- MMI error System Restart
to %d). sible!
1973
1974 Internal MMI error (NO- Internal software error. No error recovery pos- MMI error System Restart
MEM %d). sible!
1975 Internal MMI error (%d Internal software error. No error recovery pos- MMI error System Restart
to %d). sible!
1976
1977 Internal MMI error (NO- Internal software error. No error recovery pos- MMI error System Restart
MEM %d). sible!
1978 DCIO: Internal error %d In DP-slave firmware an No error recovery pos- Interface error System Restart
in DP slave firmware. uncorrectable internal er- sible!
ror has occurred.

1070 073 799-102 (02.05) GB


3–96 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


1979 DCIO: Timeout. The NC requests an up- No error recovery pos- Interface error System Restart
date of I/O data even sible!
though the data of the
previous PLC cycle
haven’t yet been handled
by the DCIO.
1980 DCIO: Configuration of The DCIO doesn’t ac- No error recovery pos- Interface error System Restart
DP slave failed. knowledge the DP-slave sible!
configuration data.
1981 DP-slave watchdog error. Within an adjustable time Check the master-data Interface error Reset of all
period there must be at file of the concerning DP channels in
least one data exchange master! ”DIAGNOS-
between DP-slave and TICS” group op-
master, otherwise time erating mode
monitoring will respond.
The monitoring is con-
tained in the master-data
file that will be sent to the
slaves during system
startup.
1982 Data exchange on PRO- Data exchange between Check the slave address, Interface error Reset of all
FIBUS DP failed. DP-master and DP-slave check the master-data file channels in
has failed or data ex- of the concerning DP ”DIAGNOS-
change is No error recov- master, check the con- TICS” group op-
ery possible! at present. nection to the DP master, erating mode
There might be an invalid check the state of the DP
master parameter set or master!
connection interrupt.
1983 APS: No memory for ex- Internal system error! No error recovery pos- Minor system System Restart
tended I/O. sible! error
1984 PXMON task not created. Internal software error. No error recovery pos- Core system in the Info dia-
Error %d. sible! warning log with softkey
”Delete warn-
ings”
1985 Internal MMI error (%d Internal software error. No error recovery pos- MMI error System Restart
to %d). sible!
1986
1987 Internal MMI error (NO- Internal software error. No error recovery pos- MMI error System Restart
MEM %d). sible!
1988 DCIO: Old hardware revi- The ASIC ”ASPC2 Step The DCIO must be ex- Interface error System Restart
sion. B” doesn’t perform the changed.
required consistency. At
least ”ASPC2 Step C” is
required.
1989 Data of auxiliary function Wrong input data in the Modify the indicated MA- Part program Reset of current
%s in MACODA block %d indicated block parame- CODA parameter. error channel
parameter %d are incon- ter.
sistent.
1990 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
to ror, invalid argument in file. indicated lisp file. error channel
1995 file %s at line %d.
1996 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, NC job ”%s” is miss- file. indicated lisp file. error channel
ing in the subsystems.
1997 NC configuration: Lisp er- Faulty entry in the lisp Correct the syntax in the Part program Reset of current
ror, job ”%s” is used file. indicated lisp file. error channel
modal and non-modal.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–97

No Error text Cause Correction Error class Reset mode


1998 Test-description file not KNB simulation software Create the simulation de- Minor system System Restart
found. has been loaded; how- scription file and load it to error
ever, the simulation de- the directory ”userFE-
scription file (e.g. PROM” or to the ”root di-
testc200.txt) is missing in rectory”.
the system path.
1999 Master parameter file not The file of the master pa- Copy the file to the ”root Interface error System Restart
found. rameter set for PROFI- directory” or to the ”user
BUS-DP doesn’t exist in FEPROM” and check the
system path. MACODA parameter
408000011.
2000 One or more PROFIBUS At least one of the slaves Check if all slaves are Interface warn- System Restart
DP slaves missing. configured in the file of connected to the bus and ing
the master parameter set if the correct master-data
doesn’t respond to the file is used.
master’s requests.
2001 Spindle %d is used by The spindle has either Release the spindle in the Part program Reset of current
another channel. been started in another corresponding channel, error channel
channel by M3 or M4 or e.g. program M5. Look it
M19 or it is reserved by up in the programmer’s
the NC functions G32 or manual.
G196.
2002 Spindle %d is used by The spindle has either Release the spindle in the Part program in the Info dia-
another channel. been started in another corresponding channel, warning log with softkey
channel by M3 or M4 or e.g. program M5. Look it ”Delete warn-
M19 or it is reserved by up in the programmer’s ings”
the NC functions G32 or manual.
G196.
2003 Internal MMI error (%d Internal software error. No error recovery pos- MMI error in the Info dia-
to %d) - further operation sible! log with softkey
2006 possible. ”Delete warn-
ings”
2007 Asynchronous axis %d The asynchronous axis Modify the part program. Part program Reset of current
has already been started. has already been started A new start can only be error channel
by this channel and executed when the axis
hasn’t reached its end has stopped.
position.
2008 Tapping with spindle %d This spindle cannot be For tapping a spindle Part program Reset of current
impossible. switched to rotary axis needs to be configured as error channel
mode. a spindle/axis in MA-
CODA 100100001 and as
a SERCOS-spindle in
MACODA 104000001.
2009 Main program has been The selected program Select the program again. Part program Reset of current
modified. has either been modified error channel
or deleted.
2010 The subprogram ”%s” ref- The selected program Select the program again. Part program Reset of current
erenced by the main pro- has either been modified error channel
gram has been modified. or deleted.
2011 Axis classification of a In the MACODA parame- Assign axis classifica- Part program in the Info dia-
channel axis is missing. ters the axis classification tions to all channel axes. warning log with softkey
(parameter 701000030) is Note: The axis classifica- ”Delete warn-
missing for an axis. tions of all axes in one ings”
channel must be different.

1070 073 799-102 (02.05) GB


3–98 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2012 FPU trap in channel. One of the following FPU Check mathematics ex- Part program Reset of current
traps occurred: underflow, pressions in part pro- error channel
overflow, division by zero gram.
or illegal operation.
2013 NC configuration: Internal Internal software error. No error recovery pos- Part program System Restart
to error, invalid node type sible! error
2014 during garbage collection
in file %s at line %d.
2015 Unknown block number Illegal or missing block Enter a valid block num- Part program Reset of current
%s. number. ber. error channel
2016 Jump destination missing. The jump destination (L- Program a jump destina- Part program Reset of current
address) of jump order tion with L-address. error channel
(G23, G24) is missing.
2017 Sub linking of modal sub- A call of modal subpro- The calling program must Part program Reset of current
program ”%s” No error re- gram was only recog- be linked, which means it error channel
covery possible!. nized at runtime. must be selected in CPL
mode and it must not
contain the ”(DIN)”
marker. The subprogram
call must not be pro-
grammed via a CPL vari-
able.
2018 Different ident numbers In a G900 block only one Program each ident num- Part program Reset of current
programmed in one NC ident number is allowed ber in a separate block. error channel
block. to be programmed.
2019 No SERCOS ident num- The ident number of the Program G900 together Part program Reset of current
ber is programmed. parameter to be written is with a ident number. error channel
not programmed.
2020 Programmed axis ad- An axis has been pro- Program only axes that Part program Reset of current
dress is not valid. grammed which either are valid SERCOS axes error channel
isn’t a SERCOS axis or it within this channel.
isn’t a member of the
concerning channel.
2021 SERCOS ident number The Parameter is write No error recovery pos- Part program Reset of current
could not be written in protected or it can’t be sible! error channel
SERCOS phase 4. written during SERCOS
phase 4.
2022 Attribute of ident number Invalid value for the attrib- Try to write the ident Part program Reset of current
is not valid. ute that delivers to the number by means of the error channel
NC data type and stan- SERCOS monitor.
dardization of the con-
cerning ident number.
2023 Programmed value is The valid limits of the Program a valid value. Part program Reset of current
to higher than the valid limit. concerning ident number Check the valid limits by error channel
2024 have been exceeded. means of the SERCOS
monitor.
2025 Ident number could not Parameter can’t be set Enter the parameter in Part program Reset of current
be written in SERCOS with G900. the SERCOS file so that it error channel
phase 4. will be loaded to the drive
during system startup.
2026 SERCOS ident number is Parameter can’t be writ- Part program Reset of current
write protected. ten. error channel
2027 No feedrate is pro- An NC block including a Program a feedrate Part program Reset of current
grammed. spindle motion can’t be value. error channel
prepared because fee-
drate is missing.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–99

No Error text Cause Correction Error class Reset mode


2028 Set actual value not al- For further information re- Switch off all offsets be- Part program in the Info dia-
lowed with zero offset ac- fer to the programmer’s fore programming G92. warning log with softkey
tive. manual. ”Delete warn-
ings”
2029 Customer specific error: Error from software PLC No error recovery pos- PLC error Reset of all
Aps_ErrorOn (%d, %d, (subsystem KNS). sible! channels in
%d). ”DIAGNOS-
TICS” group op-
erating mode
2030 Customer specific error: Error from software PLC No error recovery pos- PLC error System Restart
Aps_ErrorOn_Perm (%d, (subsystem KNS). sible!
%d, %d).
2031 Measuring probe has not Measuring probe must The distance pro- Part program in the Info dia-
been released. trigger within the G275 grammed in the NC block warning log with softkey
block. must be sufficiently long ”Delete warn-
that triggering and com- ings”
putation of the measuring
value can be performed
within this block.
2032 Interpolator-interrupt The runtime of the inter- The NC configuration Core system in the Info dia-
overrun. Runtime: %d . polation interrupt exceeds must be modified. The in- warning log with softkey
the given cycle time. In- terpolator and SERCOS ”Delete warn-
terpolation cycles may be interrupt time must be in- ings”
lost. Either too short a creased, or functions
cycle time is configured called during the inter-
or there are too many polation period must be
functions called during removed or deactivated.
the period of interpola-
tion.
2033 Time Zone MACODA-pa- Invalid MACODA param- Change the MACODA Core system in the Info dia-
rameter is invalid. eter defining time zone. parameter warning log with softkey
The displayed time is ”Delete warn-
identical with UTC time ings”
(Greenwich Mean Time).
The time zone defines the
offset between local time
and UTC time and it de-
fines whether there is
daylight saving time or
standard time. System
time is identical with UTC
time. For the display it will
be converted to local
time.
2034 Can’t build internal sys- It’s impossible to create Change the MACODA Core system in the Info dia-
tem data structure to han- an internal system data parameter warning log with softkey
dle the time zone. structure which will be ”Delete warn-
used to convert UTC time ings”
into local time. If the
structure is corrupted, the
conversion in local time
by using the function ”lo-
cal time” will not work.
The wrong time is dis-
played. The cause for this
error is probably an in-
valid MACODA parame-
ter which defines the time
zone.

1070 073 799-102 (02.05) GB


3–100 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2035 Lack of resources in Block preparation re
re- No error recovery pos
pos- Part program Reset of current
to block control. quires too manyy re-
q sible! error channel
2037 sources.
2038 Programming of ”%s” and It is not allowed to pro- Program only one of both Part program Reset of current
”%s” in one NC block is gram two or more NC NC functions. error channel
no possible. functions of the same
modal group.
2039 Unknown jump destina- Wrong name of jump Program a valid jump Part program Reset of current
to tion ”%s”.
”%s” mark or jump mark mark
mark. error channel
2040 doesn’t exist.
2041 Jump destination missing. Wrong name of jump Program a valid jump Part program Reset of current
to mark or jump mark mark
mark. error channel
2042 doesn’t exist.
2043 Axis %d: Reference point The reference point must Please reconfigure the Part program Reset of current
is not a hirth position. be a hirth position. SERCOS-parameters. error channel
2044 Programmed end point The programmed or cal- Please modify your part Part program Reset of current
to for %s-axis is no hirth culated axis coordinates program
program. error channel
2045 position. must be a hirth position.
2046 Axis %d: Calculated end The programmed or cal- Please modify your part Part program Reset of current
point is not a hirth posi- culated axis coordinates program. error channel
tion. must be a hirth position.
2047 Programmed position for A hirth place is always in- Please modify your part Part program Reset of current
%s-axis is not valid. teger number. program. error channel
2048 Programmed position for The programmed or cal- Please modify your part Part program Reset of current
%s-axis is not valid. culated axis coordinates program. error channel
must be a hirth position.
2049 Axis %d: A Hirth axis can- A Hirth axis is selected as Please check the part Part program Reset of current
not be member of a axis a slave of a coupling. program. error channel
coupling.
2050 Axis %d: A Hirth axis can- A Hirth axis is selected as Please check the part Part program Reset of current
not be member of a axis a master of a coupling. program. error channel
coupling.
2052 Reference point deleted Either the reference point Execute control reset and Servo loop or Reset of all
for %s-axis. is deleted in the drive or machine referencing. drive fault channels in
the service channel is re- ”DIAGNOS-
served. TICS” group op-
erating mode
2053 System error during proc- Internal software error. No error recovery pos- MMI error System Restart
essing of MSD data (code sible!
%d %d).
2055 System axis %d has An axis has been driven Move the axis off the Part program in the Info dia-
reached travel limit! to its travel limits by using travel limits in opposite di- warning log with softkey
jog mode. rection. ”Delete warn-
ings”
2056 Commanded incremental The selected incremental Select a motion that Part program in the Info dia-
jog movement (Axis %d) motion would exceed the doesn’t exceed the axis warning log with softkey
would increase the travel axis travel limit. travel limit. ”Delete warn-
limits! ings”
2057 Error %d reading MA- Internal software error. No error recovery pos- MMI error System Restart
CODA parameter %d. sible!
2058 System error in DLS Internal software error. No error recovery pos- MMI error System Restart
event handler (%d %d). sible!
2059 Text missing. Internal software error. No error recovery pos- Serious system System Restart
sible! error

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–101

No Error text Cause Correction Error class Reset mode


2060 Synchronous axis of Therefore axis cannot be Execute control reset. Part program Reset of current
channel %d is temporary reserved. Attention: This will stop error channel
drive interpolated. the drive controlled axis
interpolation.
2061 System axis %d is tempo- In this state the axis can- The axis must be Part program Reset of current
rary drive interpolated. not be jogged. switched to NC controlled error channel
interpolation.
2062 Insufficient memory for Too large values for stack Reduce data ranges in Part program Reset of current
data areas of CPL pro- and link table are defined MACODA parameter warning channel
grams. in MACODA block num- 707000010 and initiate a
ber 707000010 ”Data new system startup.
areas for CPL programs”.
2063 Can’t access file ”%s”. During access via net- The net load must be re- Part program Reset of current
work, timeouts might oc- duced. error channel
cur inhibiting file access
to an already selected
file. The concerning file
might be deleted.
2064 No more memory for in- There are more than 15 No error recovery pos- Part program System Restart
sertion of an axis reset coordinate modifying sible! error
function! functions active.
2065 Initialization of PROFI- Initialization of PROFI- Check the hardware and DNC error System Restart
BUS controller failed. BUS controller ISA_2P exchange it if necessary.
failed. For version V2.x
an ISA_2P with
CP5412-A1 is needed. In
version V3 PROFIBUS
FMS is not supported.
From version V4.2.x an
ISA_2P with PROFI
board is needed. Differ-
ence: CP5412-A1 has
glass fiber connectors
whereas PROFI board
has none.
2066 PROFIBUS firmware file Access to firmware file No error recovery pos- DNC error System Restart
”%s” not found. needed by PROFI board sible!
No error recovery pos-
sible!.
2067 Can’t set time zone envi- The system manager No error recovery pos- Core system in the Info dia-
ronment on one of the cannot send data for set- sible! warning log with softkey
hardware modules. ting the time zone to one ”Delete warn-
of the modules in the ings”
rack. During system
startup, data will be trans-
ferred to the dual-port of
each active module. At
least one of the modules
doesn’t respond.
2068 Can’t set date and time The system manager No error recovery pos- Core system in the Info dia-
on one of the hardware cannot send data for set- sible! warning log with softkey
modules. ting date and time to one ”Delete warn-
of the modules in the ings”
rack. During system
startup, data will be trans-
ferred to the dual-port of
each active module. At
least one of the modules
doesn’t respond.

1070 073 799-102 (02.05) GB


3–102 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2069 PLC spindle order failed. Commands from the PLC The reserved channels Part program Reset of current
are handled by an inter- have to be released by error channel
nal channel. This channel system control reset.
is reserved, for example
by an auxiliary function
not yet acknowledged.
2070 The actual maximum axis Hostlib version: Servo er- Please check the prob- Part program Reset of current
velocity is higher than ror! lem. Possible reasons are error channel
MACODA parameter. wrong contour vectors,
endpoints or feed limits.
2071 The actual axis slope ac- Hostlib version: Servo er- Please check the prob- Part program in the Info dia-
celeration is higher than ror! lem. Possible reasons are warning log with softkey
MACODA parameter. wrong contour vectors, ”Delete warn-
endpoints or feed limits. ings”
2072 Internal MMI error (%d Internal software error. No error recovery pos- MMI error System Restart
%d). sible!
2073 Wrong format of DP mas- Probably the file has Copy the correct file to Interface error System Restart
ter parameter file. been transferred in ASCII the root directory or to the
format. user FEPROM.
2074 Missing module address Configuration file was Correct the DP master Interface error System Restart
in DP master parameter created by WinDp without parameter file by means
file. the module addresses. of ”WinDp” and copy it to
the directory root direc-
tory or to the user FE-
PROM.
2075 Modification of database Protocol and source files No error recovery pos- Minor system System Restart
file: Error during file han- for modification of the da- sible! error
dling operations (NCS- tabase file are checked
Code %d, FSR-Code for existence and access
%d). rights and renamed by
NCS functions. During
this check an error oc-
curred.
2076 Modification of database The function DBVRE- No error recovery pos- Minor system System Restart
file: Error code %d from CONF or DBVDDL of the sible! error
database kernel. See log database kernel returned
files for details. the indicated error code
during database modifica-
tion. For the meaning of
the error code look up the
BAPAS database manual.
Protocol and source files
contain further informa-
tion.
2077 Can’t initialize page-level The initialization of page- No error recovery pos- Core system in the Info dia-
protection. level protection failed. Ei- sible! warning log with softkey
ther the central page ”Delete warn-
table couldn’t be created ings”
or activation of the MMU
failed. The system runs
without memory protec-
tion.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–103

No Error text Cause Correction Error class Reset mode


2078 Error during initialization The number of places de- You can modify the maxi- Minor system System Restart
of tool database: you can fined in file ”toolprms.xxx” mum number of data re- error
define a maximum num- in groups 1 to 30 is too cords. For more informa-
ber of %d data records. great. tion see manual ’Tool
management – Parame-
terization, ’Database
parameterization’ section.
2079 Too much report requests Internal software error. No error recovery pos- MMI error System Restart
in tool data server. sible!
2080 Internal MMI-Error in tool Internal software error. No error recovery pos- MMI error System Restart
management (%d, %d). sible!
2081 CPL axis function: Index No more than 8 axes may Program an axis index Part program Reset of current
of channel axis is too big be configured per chan- less than or equal to 8. error channel
(max. 8)! nel.
2082 CPL axis function: Index No more than 16 axes Program an axis index Part program Reset of current
of system axis is too big may be configured in the less than or equal to 16. error channel
(max. 16)! system.
2083 Abort event without possi- The block controller re- No error recovery pos- Serious system System Restart
bility to abort. ceived a command to ter- sible! error
minate but it is not able to
execute the command.
2084 Too many files open. There are either too many Open less files at the Part program Reset of current
to levels in subprogram call same time. Reduce the error channel
2086 chain or too many files subprogram call chain. In-
are opened by CPL at the crease the concerning
same time. MACODA parameter.
2087 Multiple opened file %s. Internal software error. No error recovery pos- Part program Reset of current
Attempt to open a file that sible! error channel
is already open. A file
close operation failed or
is missing.
2088 File operations in channel A file open operation, e.g. File operations are not al- Part program Reset of current
%d are not permitted. by a subprogram call, is lowed within an auxiliary error channel
not approved in an auxil- channel.
iary channel.
2089 Insufficient free memory The reserved memory in No error recovery pos- Serious system System Restart
space. SRAM for saving error sible! error
messages of critical sys-
tem errors and startup
messages is too small.
The error will only occur
during the developing
phase.
2090 Can’t create page table There is not enough me- No error recovery pos- Serious system System Restart
to for task %s . mory left to create the sible! error
2092 page table for a task. The
page table is needed for
the memory protection
performed by memory
management unit (MMU).

1070 073 799-102 (02.05) GB


3–104 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2093 Watchdog error on mo- The watchdog logic on a No error recovery pos- Hardware error in the Info dia-
dule in slot %d . hardware module of the sible! log with softkey
NC recognized an error. ”Delete warn-
The error was transferred ings”
to the system manager
module in slot 0 (SMNC,
SMNB, SNCI,...) via sys-
tem bus and an NMI was
triggered. The reaction of
the system manager mo-
dule depends on the type
of module that sent the
error. The reaction
reaches from ”no reac-
tion” up to ”Ready signal
off”.
2094 Can’t activate the MMU. The memory manage- No error recovery pos- Core system in the Info dia-
Memory protection is not ment unit (MMU) cannot sible! warning log with softkey
active. be activated. The system ”Delete warn-
runs without memory ings”
protection. Stack and
data of each task are not
protected against write
access. Unused address
ranges are not controlled.
There are multiple
causes: insufficient me-
mory for creating the
page table, error when
activating the MMU, and
so on. Except for this, the
system runs normally.
2095 The maximum jog-block The number of blocks to Increase the appropriate Part program by mode
count (%d) is reached. be executed in jog mode value in the MACODA pa- warning change
Any further jog-block is greater than applied in rameters.
won’t be remembered. MACODA.
2096 Internal error during in- Software error. No error recovery pos- Part program Reset of current
to sertion of a NC function. sible! error channel
2098
2099 Channel %d is busy wait- The concerning channel Stop CPL and set inter- Part program by mode
ing in CPL or for interface doesn’t accept one of the face signals. error change
signals, please close CPL commands ”return to
or set corresponding in- path” or ”cancel distance”
terface signals. because it is waiting for
digital input signals or
CPL is active.
2100 Out of memory. No more free memory. The software applications Minor system System Restart
that need channel me- error
mory have to be rede-
signed.
2101 No valid data for auto- Only automatic retraction Please use manual re- Part program Reset of current
matic tapping retraction. is available when tapping traction. error channel
was interrupted by control
reset.
2102 No direction of rotation Tapping requires specifi- The rotation direction is Part program Reset of current
programmed. cation of the spindle rota- always commanded by error channel
tion direction. M3 (right-hand thread)
and M4 (left-hand
thread).

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–105

No Error text Cause Correction Error class Reset mode


2103 Tapping retraction: Tapping retraction must Please modify the part Part program Reset of current
Spindle %d is not in C- be initialized with G9321. program. Insert a new error channel
axis mode. line with G9321.
2104 Tapping retraction, Drive controlled switching Bit 8 must not be set in Part program Reset of current
spindle %d : SERCOS must not be activated in S-0-0033. error channel
secondary operation S-0-0033. Hint: S-0-0033 is local-
mode 1 is wrong config- ized in the SERCOS-file
ured. for phase 2.
2105 No channel axis enabled One axis in channel must Part program Reset of current
for measuring probe. be enabled for measuring error channel
probe function (MACODA
parameter 100300012).
2106 Error on digital high On writing the digital out- Check the high speed Interface warn- in the Info dia-
speed output. puts a voltage fault was outputs on the DCIO and ing log with softkey
recognized. check the connector for ”Delete warn-
short circuit or open con- ings”
nection. If necessary ex-
change the defect com-
ponent.
2107 Switching the NC block A high speed input must Please modify the part Part program Reset of current
via high speed input: be specified. E.g.: G575 program. error channel
Missing or wrong param- HS3=1.
eter.
2108 Switching of NC block via The G-code for switching Please check and modify Part program Reset of current
high speed input: Wrong the NC block via digital the part program. error channel
interpolation type. high speed input is ap-
proved exclusively with
real linear blocks (G0,
G1, G10, G11). Blocks
without motion are not
approved. Within a part
program the same condi-
tion is also valid for the
next block.
2109 Switching of NC block via Internal software error. No error recovery pos- Part program Reset of current
high speed-Input: Internal sible! error channel
error: %s is already used
by another function.
2110 Switching NC block via The G-code for switching Please modify the part Part program Reset of current
high speed input: Wrong the NC block via digital program. error channel
interpolation type in next high speed input is ap-
NC block. proved exclusively with
real linear blocks (G0,
G1, G10, G11). Blocks
without motion are not
approved. Within a part
program the same condi-
tion is also valid for the
next block.
2111 Switching of NC block via Because of a pro- If possible, delete the Part program Reset of current
high speed input: Look grammed or implicit WAIT WAIT command. Please error channel
ahead could not be exe- the next NC block could note that some N -func-
cuted. not be read. tions include a implicit
WAIT.
2112 Cutter Compensation: No NC function cutter com- Test whether the NC Part program Reset of current
method for contour transi- pensation (G41/G42) has function G68 (circular arc) error channel
tion active. no valid method to handle or G69 (intersection) is
contour transitions. active.

1070 073 799-102 (02.05) GB


3–106 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2113 Cutter Compensation: No Internal error: G41/G42 No error recovery pos- Part program Reset of current
valid analysis quadrant didn’t find a valid analysis sible! error channel
found. quadrant to compute a
contour transition for the
concerning geometry.
2114 Cutter compensation: No Block control cannot Check the adjusted look Part program Reset of current
more look ahead pos- make available the re- ahead for Cutter com- error channel
sible. quired number of blocks pensation (G500 VS..) as
that G41/G42 needs for well as the adjusted look
look ahead . ahead for the system
(MACODA parameter or
programmed ”PREP-
NUM”). It may be neces-
sary to increase the me-
mory reserved for the
channel.
2115 Cutter Compensation: There was an attempt to Modify the part program Part program Reset of current
Tool change only for lin- modify either tool radius so that a change of the error channel
ear contour segments or direction of cutter com- compensation direction or
possible. pensation while circular of the tool radius will only
or helical motion was ac- be active on linear con-
tive. tour segments.
2116 Cutter compensation: No Internal error: G41/G42 Modify the part program Part program Reset of current
compensation direction failed in generating an in- so that a change of the error channel
for insert block. sertion block, because a compensation direction or
valid shift direction for of the tool radius will only
cutter compensation was be active on linear con-
not found. tour segments.
2117 No act/deactivation of Cutter compensation can Modify the part program Part program Reset of current
compensation in circles exclusively be switched so that switching on and error channel
possible. on or off while linear mo- off of the cutter com-
tion is active. pensation occurs in a lin-
ear contour segment.
2118 Unknown geometry clas- Cutter compensation Modify the part program Part program Reset of current
sification for cutter com- works exclusively on lin- so that during active cut- error channel
pensation. ear, circular or helical ele- ter compensation only lin-
ments. ear circular or helical ele-
ments are programmed.
2119 Cutter compensation: This programming is use- Check your part program. Part program Reset of current
G40 straight after less, because cutter com- error channel
G41/G42 not valid. pensation is switched off
immediately after it is ac-
tivated.
2120 Cutter compensation: There might be a colli- Change the applied tool. Part program Reset of current
Tool radius bigger than sion. For inside circle Use a smaller cutter. error channel
circle radius. compensation the tool ra-
dius must be smaller than
the contour circle radius.
2121 Cutter compensation: The programmed coordi- Check the programming Part program Reset of current
Circle without movement nates for a circular motion of your part program. error channel
programmed. are identical to those of Hint: Only with center
the previous block. point programming is
possible for full circles.
2122 Correction activation only There was an attempt to Modify your part program Part program Reset of current
for linear segments pos- activate cutter compensa- in such a way that the error channel
sible. tion although no linear cutter compensation is al-
motion was active. ways switched on in a lin-
ear segment.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–107

No Error text Cause Correction Error class Reset mode


2123 Correction deactivation There was an attempt to Modify your part program Part program Reset of current
only for linear segments deactivate cutter com- in such a way that the error channel
possible. pensation although no lin- cutter compensation is al-
ear motion was active. ways switched off in a lin-
ear segment.
2124 Cutter Compensation: No Internal error of cutter No error recovery pos- Part program Reset of current
valid compensation rule. compensation. sible! error channel
2125 No compensation rule for Internal error: Cutter com- No error recovery pos- Part program Reset of current
G40 block. pensation didn’t find a sible! error channel
valid correction rule in the
block that deactivates
compensation.
2126 Cutter compensation: Internal error in cutter No error recovery pos- Part program Reset of current
Circle tangent cannot be compensation: Attempt to sible! error channel
evaluated. evaluate a tangent for a
circular block without mo-
tion.
2127 Cutter Compensation: Cutter compensation: At- No error recovery pos- Part program Reset of current
Line tangent cannot be tempt to evaluate a tan- sible! error channel
evaluated. gent for a linear block
without a motion.
2128 Programmed loop gain is Loop gain may be applied Program a valid value for Part program Reset of current
not valid. from 0.00 to 655.35. The loop gain. error channel
scaling value is 0.01 (m/
min)/mm (2 digits after
decimal point).
2129 G92 is No error recovery For zero resetting linear Use G105 for linear mo- Part program Reset of current
possible! for linear mo- modulo axes a specific dulo axes. error channel
dulo axis. function must be used
that takes modulo com-
putation into account.
2130 Data exchange with DP The DP-Slave didn’t have No error recovery pos- Interface warn- in the Info dia-
slave disturbed (DP slave any data traffic longer sible! ing log with softkey
address %d). than 10 data interchange ”Delete warn-
loops. ings”
2131 File ”%s” has been multi- In an NC program a sub- Avoid recursive calls. Part program Reset of current
ply or recursively opened. program appears more error channel
than once in the same
call chain.
2132 Access error for file ”%s”. File access error: Prob- If the error occurs repeat- Part program Reset of current
to ably network problems. edly, please inform the af- error channel
2133 ter sales service.
2134 File access error. File access error: Prob- If the error occurs repeat- Part program Reset of current
to ably network problems. edly, please inform the af- error channel
2138 ter sales service.
2139 Return to path needs Attempt to return to path Use another channel. Part program Reset of current
feed axis. in a channel without feed error channel
axes.
2140 Too little memory for %d Insufficient channel me- No error recovery pos- Part program Reset of current
jog blocks during return to mory. sible! error channel
path.
2141 Internal error with axis Internal error. No error recovery pos- Part program Reset of current
%d during return to path. sible! error channel
2142 Correction number for Range for tool length Program a H value in the Part program Reset of current
tool length invalid. compensation: H1 .. H48. range between 1 and 48. error channel

1070 073 799-102 (02.05) GB


3–108 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2143 Correction number for Range for tool radius Program a D value in the Part program Reset of current
tool radius invalid. compensation: D1 .. D48. range between 1 and 48. error channel
2144 Modal subprogram call A modal subprogram is Link programs com- Part program Reset of current
without link table. called in a program that’s pletely. error channel
selected in DIN mode.
2145 Bad firmware version for The firmware version of Provide a hardware mo- Hardware error System Restart
ISA_2-PROFI. the FMS controller dule with the correct firm-
ISA_2-PROFI is wrong. ware version.
2146 Installation of DCIO driver Internal system error! No error recovery pos- Serious system System Restart
to failed. sible! error
2150
2151 One or more PROFIBUS At least one of the slaves Check if all slaves are Interface warn- System Restart
DP slaves missing. configured in the file of connected to the bus and ing
the master parameter set if the correct master-data
doesn’t respond to the file is used.
master’s requests.
2152 Master parameter file not The file of the master pa- Copy the file to the ”root Interface error System Restart
found. rameter set for PROFI- directory” or to the ”user
BUS-DP doesn’t exist in FEPROM” and check the
system path. MACODA parameter
408000011.
2153 Wrong format of DP mas- Probably the file has Copy the correct file to Interface error System Restart
ter parameter file. been transferred in ASCII the root directory or to the
format. user FEPROM.
2154 Missing module address Configuration file was Correct the DP master Interface error System Restart
in DP master parameter created by WinDp without parameter file by means
file. the module addresses. of ”WinDp” and copy it to
the directory root direc-
tory or to the user FE-
PROM.
2155 Unknown error during During DP-master config- No error recovery pos- Interface error System Restart
PROFIBUS DP configura- uration an unknown error sible!
tion (%d). occurred.
2156 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
tem DIO (Error Codes %d sible! error
%d).
2157 Invalid value of MACODA The indicated MACODA Enter MACODA value Interface error System Restart
parameter %d. parameter has an invalid and keep the specified
value. The value range range.
defined in MACODA is
discarded.
2158 Subprogram name for The subprogram name is Enter subprogram name Part program Reset of current
’G%d’ is missing. missing in MACODA. in MACODA. error channel
2159 Subprogram name for The subprogram name is Enter subprogram name Part program Reset of current
’M%d’ is missing. missing in MACODA. in MACODA. error channel
2160 Subprogram name is The subprogram name is Enter subprogram name Part program Reset of current
missing for %s. missing in MACODA. in MACODA. error channel
2161 Programmed transition Only angles in the range Program a transition Part program Reset of current
angle is not valid! from 0 to 50 degrees are angle between 0 and 50 error channel
allowed. degrees.
2162 No access to file The file cpldlg05.dlg Set access right execute MMI error in the Info dia-
cpldlg05.dlg. doesn’t have the correct ”x” to file cpldlg05.dlg. log with softkey
access rights. The ac- ”Delete warn-
cess right must be set to ings”
execute ”x” at least.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–109

No Error text Cause Correction Error class Reset mode


2163 Conflicting addresses for MACODA parameters for Correct MACODA Interface error System Restart
digital I/Os. inputs and outputs are parameter.
wrong (MACODA group
4075). The allocated ad-
dresses lead to overlap-
ping address ranges.
2164 Conflicting addresses for The addresses defined Check MACODA parame- Interface error System Restart
digital I/Os and PROFI- for inputs and outputs ter and master-data file
BUS DP. (MACODA group 4075) and correct the conflicting
overlap with the ad- addresses.
dresses defined for PRO-
FIBUS DP (see master
parameter set).
2165 Analog I/O of DCIOs This DCIO card is a ver- Change hardware module Interface error System Restart
missing. sion without analog inputs DCIO against another
or outputs. hardware version.
2166 Conflicting addresses for The addresses (MA- Check MACODA-Param- Interface error System Restart
central I/Os and PROFI- CODA group 4075) de- eter, master-data file and
BUS DP fined for I/Os or PROFI- the addresses of central
BUS-DP (see master pa- I/O and correct the con-
rameter set) inputs and flicting addresses.
outputs are overlapping
with the addresses of
central input/output.
2167 Tool already destroyed The radius of the se- Adjust your part program Part program Reset of current
contour while activating lected tool is so big that accordingly or use a error channel
the cutter compensation. during activation of the smaller tool.
cutter tool compensation
the programmed contour
would be destroyed.
2168 Program for channel %d The program has been Start the program in the Part program Reset of current
in channel %d started. selected in the wrong right channel. error channel
channel.
2169 Cutter compensation will Cutter tool compensation Modify your part program Part program Reset of current
to delete block because of tries to eliminate a NC in one of the following error channel
2170 detected collision. block because collision ways: 1. Split the NC
monitoring detected a col- blocks and shift the colli- Part program
lision, and the concerning sion out of the look ahead warning
NC block lies between range. 2. Reduce the
the collision points.
points A col- look-ahead range with
lision occurs when a loop G500. 3. Switch off colli-
is detected for the com- sion monitoring (G544).
puted offset contour 4. Check if a program-
within the selected plane ming error exists.
and within the adjusted
look-ahead range.
2171 No memory for %s-com- For the execution of this It is necessary to make Part program Reset of current
mand. command internal me- more memory available error channel
mory is needed. But there for the system for exam-
is no more memory avail- ple by decreasing the
able. number of channels or by
using another hardware
module.
2172 Minimum 3 axis needed The machine type is not No error recovery pos- Part program Reset of current
for ”inclined plane func- appropriate for the func- sible! error channel
tion”. tionality ”inclined plane”.

1070 073 799-102 (02.05) GB


3–110 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2173 Wrong value at master The value at the master Adjust syntax in NC pro- Part program Reset of current
axis. axis name in the NC gram. error channel
block must be 1, 0 or -1.
2174 Slave axis %d is already A master axis may not be Delete first the axis union Part program Reset of current
master axis of another used as slave axis in of the programmed axis error channel
axis union. another axis union. in the NC program. The
slave axis can then be
programmed.
2175 More than one master An attempt was made to Adjust syntax in NC pro- Part program Reset of current
axis programmed. create more than one gram. error channel
axis union in the NC
block or the syntax for a
slave axis is wrong. The
name of the slave axis
must be followed by a pa-
rameter list in paren-
theses.
2176 Couple factor and modulo A coupling of modulo Adjust the coupling factor Part program Reset of current
values of axes %d and axes via a linear coupling or the axis modulo values error channel
%d don’t match. relation requires that the (MACODA parameter).
modulo values Mm and
Ms of the master and the
slave axis respectively
obey the equation Mm*k
mod Ms = 0, where k is
the programmed coupling
factor.
2177 Inadmissible coupling of It is No error recovery Define master axis as Part program Reset of current
non-modulo axis %d to possible! to couple a non- non-modulo axis in MA- error channel
modulo axis %d. modulo axis to a modulo CODA or perform cou-
axis via a linear coupling pling via a coupling table.
relation.
2178 Coupling table of slave The master axis is a lin- Change value at the indi- Part program Reset of current
axis %d is not suited for ear axis. The x-values of cated ident number in the error channel
linear master axis %d. the points in the coupling coupling table.
table still have an angular
unit (ident number #11).
2179 Coupling table of slave The master axis is a Change value at the indi- Part program Reset of current
axis %d is not suited for rotary axis. The x-values cated ident number in the error channel
rotary master axis %d. of the points in the cou- coupling table.
pling table still have a
length unit (ident number
#11).
2180 Coupling table unsuitable The slave axis is a linear Change value at the indi- Part program Reset of current
for linear slave axis. axis. The y-values of the cated ident number in the error channel
points in the coupling coupling table.
table still have an angular
unit (ident number #12).
2181 Coupling table unsuitable The slave axis is a rotary Change value at the indi- Part program Reset of current
for rotary slave axis. axis. The y-values of the cated ident number in the error channel
points in the coupling coupling table.
table still have a length
unit (ident number #12).

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–111

No Error text Cause Correction Error class Reset mode


2182 Wrong period in coupling The master axis is a mo- Change period (x-value of Part program Reset of current
table for slave axis %d dulo axis with modulo last point) in the coupling error channel
and master axis %d. value Mm (drive parame- table.
ter). The period p in the
coupling table must there-
fore obey the equation
Mm mod p = 0.
2183 Inadmissible non-periodic The master axis is a mo- Change value at the indi- Part program Reset of current
function in coupling table dulo axis. The function in cated ident number in the error channel
for slave axis %d and the coupling table must coupling table.
master axis %d. therefore be periodic (id-
ent number #20 1).
2184 Programmed coupling A motion of the master Change programmed Part program Reset of current
relation for slave axis %d axis over the total defini- coupling relation or the error channel
is not consistent with first tion range of the coupling values in the coupling
negative travel limit. table would lead to a table.
slave axis motion reach-
ing its first negative travel
limit.
2185 Programmed coupling A motion of the master Change programmed Part program Reset of current
relation for slave axis %d axis over the total defini- coupling relation or the error channel
is not consistent with first tion range of the coupling values in the coupling
positive travel limit. table would lead to a table.
slave axis motion reach-
ing its first positive travel
limit.
2186 Programmed coupling A motion of the master Change programmed Part program Reset of current
relation for slave axis %d axis over the total defini- coupling relation or the error channel
is not consistent with first tion range of the coupling values in the coupling
positive travel limit. table would lead to a table.
slave axis motion reach-
ing its second negative
travel limit.
2187 Programmed coupling A motion of the master Change programmed Part program Reset of current
relation for slave axis %d axis over the total defini- coupling relation or the error channel
is not consistent with sec- tion range of the coupling values in the coupling
ond positive travel limit. table would lead to a table.
slave axis motion reach-
ing its second positive
travel limit.
2188 NC Function could not be The NC function ”axis No error recovery pos- Part program Reset of current
inserted. coupling off”couldn’t be sible! error channel
inserted. Internal software
error.
2189 Valid dynamic limit for An axis coupling via a Perform a dry run with re- Part program Reset of current
master axis %d not coupling table with cubic duced feed rate before warning channel
found. spline interpolation be- the final machining.
tween the points leads to
an additional acceleration
(radial acceleration) of
the slave axis. In order to
keep the slave axis accel-
eration below its MA-
CODA value the master
axis maximum velocity as
well as its acceleration
must be decreased. The
internal algorithm didn’t
find a valid solution.

1070 073 799-102 (02.05) GB


3–112 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2190 Axis coupling: File name From the coupling table Use a shorter name for Part program Reset of current
%s too long. name the name of the the coupling table. Ac- error channel
spline table including the cordingly the resulting
directory path is deduced. spline table name will be
This resulting file name is shorter.
too long.
2191 Coupling table %s The coupling table indi- Modify the indicated file Part program Reset of current
doesn’t exist. cated in the NC block or copy it to the search error channel
wasn’t found in the sub- path or change the
program search path. The search path.
search path (MACODA
parameter) is wrong or
the file doesn’t exist.
2192 Error accessing file %s. Function No error recovery pos- Part program Reset of current
Detailed code: %d %d. Ncs_Fsr_path_open re- sible! error channel
turned an error.
2193 Error closing file %s. De- Function Ncs_Fsr_close No error recovery pos- Part program Reset of current
tailed code: %d %d. returned an error. sible! error channel
2194 File %s couldn’t be Function Ncs_Fsr_open No error recovery pos- Part program Reset of current
created. returned an error. sible! error channel
2195 Error in coupling table The interpolation type (id- Change value at the indi- Part program Reset of current
%s: Wrong type of inter- ent number #1) in the cated ident number in the error channel
polation between points. coupling table is wrong. It coupling table.
may have the values 1 or
3.
2196 Error in coupling table The coupling table con- Set the x-value of the first Part program Reset of current
%s: x-value of the first tains a period (ident num- point or period to zero. error channel
point not equal to zero. ber #20) greater than
zero. The x-value of the
first point must therefore
be zero.
2197 Axis coupling: Calculation For the indicated coupling No error recovery pos- Part program Reset of current
of spline coefficients table in the NC block sible! error channel
failed. spline coefficients must
be calculated and in-
serted in the correspond-
ing spline-table file. The
calculation failed due to a
non-specific error.
2198 Error in coupling table The function in the cou- Set the y-value of the first Part program Reset of current
%s: First and last point pling table is periodic (id- point equal to the y-value error channel
have different y-values. ent number #20 1). The of the last point or set the
y-values of the first and period to zero.
last point must hence be
equal.
2199 No master axis pro- Missing syntax element Please check and modify Part program Reset of current
grammed. <axname><n> with n = 1, the part program. error channel
0 or -1.
2200 Error in coupling table The x-values in the indi- Sort points in coupling Part program Reset of current
%s: x-value of point %d is cated coupling table are table in ascending order error channel
greater than the succeed- not in ascending order. of the x-values.
ing value.
2201 Error in coupling table The unit of the y-values Change value at the indi- Part program Reset of current
%s: Wrong unit for y-val- (ident number #12) is cated ident number in the error channel
ues (ident number #%d). wrong. coupling table.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–113

No Error text Cause Correction Error class Reset mode


2202 Error in coupling table The indicated coupling Discard the ident number Part program Reset of current
%s: Unknown ident num- table contains an un- from the coupling table or warning channel
ber #%d. known ident number. The use a newer software ver-
ident number is ignored. sion that recognizes this
ident number.
2203 General read error in file The interpretation of the Check file syntax. Part program Reset of current
%s, line %d. indicated file has been in- error channel
terrupted before the file
end. This might be
caused by a syntax error
in the indicated line.
2204 Error in coupling table The coupling table must Define points in the indi- Part program Reset of current
%s: No or too few points contain at least two points cated coupling table. error channel
defined. for linear interpolation be-
tween the points. For cu-
bic spline interpolation it
must contain at least
three points.
2205 Error in coupling table The interpretation of the Check file syntax. Part program Reset of current
%s: General syntax error indicated file has been in- error channel
in line %d. terrupted before the file
end. This might be
caused by a syntax error
in the indicated line.
2206 Slave axis %d has a zero A coupling table with lin- Define a velocity step Part program Reset of current
maximum velocity step ear interpolation between change for the indicated error channel
change. the points leads to veloc- slave axis in MACODA or
ity step changes of the use cubic spline inter-
slave axis if the master polation in the coupling
axis moves with constant table.
velocity. Therefore the
maximum velocity of the
master axis is reduced so
that the slave axis doesn’t
exceed its maximum ve-
locity step change (MA-
CODA parameter). A zero
step change of the slave
axis wouldn’t therefore al-
low any motion of the
master axis.
2207 Inadmissible motion for In the NC program a mo- Please check and modify Part program Reset of current
slave axis %d. tion was programmed for the part program. error channel
a coupled axis. This is not
allowed.
2208 No table for inclined On activating an inclined Create table and select it Part program Reset of current
plane activated. plane a corresponding in the part program via error channel
table must be selected. G22 ID<table name>.
2209 Illegal tool axis %d. The tool axis doesn’t exist Correct tool axis number Part program Reset of current
or is part of the working in part program or in MA- error channel
plane. CODA parameter
705000210.
2210 Selected tool axis %d has The tool axis type in part Modify the axis type or Part program Reset of current
wrong axis type. program or in MACODA select another tool axis. error channel
parameter 705000210 is
not rotary or endless.

1070 073 799-102 (02.05) GB


3–114 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2211 Offset angle out of range The programmed angle in Modify the offset angle in Part program Reset of current
(-180..+180). the part program is in- the part program. error channel
valid.
2212 Difference of the tool axis Because of a WAIT block Insert a block without mo- Part program Reset of current
position is too large. an intersection block tion after the WAIT block. error channel
couldn’t be inserted.
2213 G131 is programmed to- There is another axis pro- Remove wrongly pro- Part program Reset of current
gether with an axis mo- grammed beside the tool grammed axes from error channel
tion. axis. block.
2214 Selected operation mode Oscillation function is not Select operation mode Part program Reset of current
not valid for oscillation suitable for single step or automatic or single block. error channel
function. single program block.
2215 Before switching A move command must Please program the Part program Reset of current
G41-G42 a move com- be programmed inside switch of cutter com- error channel
mand must be pro- the block before cutter pensation side after a
grammed. compensation switch. block with a move com-
mand.
2216 Writing of external zero During writing of the ex- Please check your part Part program Reset of current
offset via CPL has been ternal zero offset data via and PLC program for a error channel
interrupted. CPL, the PLC also tried possible conflict during
to write them. Attention: the writing/reading of the
The correction data in the external correction data
NC is now inconsistent (timing problem).
and must be re-initialized.
2217 Reading of external zero During reading of the ex- Please check your part Part program Reset of current
offset data via CPL has ternal zero offset data via and PLC program for a error channel
been interrupted. CPL, the PLC also tried possible conflict during
also to write them. Atten- the writing/reading of the
tion: The correction data external correction data
in the NC is now inconsis- (timing problem).
tent and must be re-ini-
tialized.
2218 Writing of external length During writing of the ex- Please check your part Part program Reset of current
correction via CPL has ternal length correction and PLC program for a error channel
been interrupted. data via CPL, the PLC possible conflict during
also tried to write them. the writing/reading of the
Attention: The correction external correction data
data in the NC is now in- (timing problem).
consistent and must be
re-initialized.
2219 Reading of external During reading of the ex- Please check your part Part program Reset of current
length correction via CPL ternal length correction and PLC program for a error channel
has been interrupted. data via CPL, the PLC possible conflict during
also tried to write them. the writing/reading of the
Attention: The correction external correction data
data in the NC is now in- (timing problem).
consistent and must be
re-initialized.
2220 Writing of external cutter During writing of the ex- Please check your part Part program Reset of current
data via CPL has been in- ternal cutter radius via and PLC program for a error channel
terrupted. CPL, the PLC also tried possible conflict during
to write them. Attention: the writing/reading of the
The correction data in the external correction data
NC is now inconsistent (timing problem).
and must be re-initialized.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–115

No Error text Cause Correction Error class Reset mode


2221 Reading of external cutter During reading of the ex- Please check your part Part program Reset of current
radius correction via CPL ternal cutter radius via and PLC program for a error channel
has been interrupted. CPL, the PLC also tried possible conflict during
to write them. Attention: the writing/reading of the
The correction data in the external correction data
NC is now inconsistent (timing problem).
and must be re-initialized.
2222 Symmetry 0 not allowed. Symmetry 0 pro- Modify part program. Part program Reset of current
grammed. error channel
2223 G350 not allowed while Changing the oscillation Program G1 together with Part program Reset of current
oscillation (G301) is ac- parameters is not allowed G350 and activate G301 error channel
tive. while an oscillation is still again in the following
active. block.
2224 Spindle %d is not config- Internal software error. No error recovery pos- Part program Reset of current
ured. sible! error channel
2225 Spindle couple %d is not The programmed function Please check your part Part program Reset of current
activated. works only with a spindle program. error channel
couple.
2226 %s: Parameter %s is The printed parameter is Please modify the part Part program Reset of current
missing. needed by the NC func- program. error channel
tion.
2227 Only 4 spindle couples A spindle couple > 4 is Please check the part Part program Reset of current
are allowed. programmed. program. error channel
2228 The maximum Input value The maximum input Please modify your part Part program Reset of current
is: %f . range is exceeded. program. Use a value error channel
within the allowed range.
2229 Spindle %d: SERCOS S-0-0034 must be config- Please modify S-0-0034. Part program Reset of current
secondary operation ured with position-inter- Hint: S-0-0034 is local- error channel
mode 2 is wrong config- face. ized in the SERCOS-file
ured. for phase 2.
2230 Invalid value for a SCC- Information about valid Please check and modify Part program Reset of current
parameter. values and its meaning the part program. error channel
can be taken from the
DIN Programming
manual.
2231 Master and slave are A spindle can not be a Please check your part Part program Reset of current
identical. master and a slave at the program. error channel
same time.
2232 SpindleCoupleConfigura- SCD (SpCoupleDis- Please check your part Part program Reset of current
tion: Only one NC-func- tance), program. error channel
tion is allowed per line. SCSW(SpCoupleSync-
Window) or
SCEW(SpCoupleSyncEr-
rorWindow) cannot be
used together in one NC-
Block. Please split the
line.
2233 Spindle %d: SERCOS A position controlled Please modify the SER- Part program Reset of current
S-0-0047 is missing in spindle needs the COS configuration file for error channel
S-0-0024(MDT). S-0-0047 as a part of the phase 2.
MDT.
2234 Spindle %d: Gear switch Switching the spindle Please check your part Part program Reset of current
is not allowed while posi- gear is only available with program. error channel
tion interface is active. a speed controlled
spindle (SDOM Sx=0).

1070 073 799-102 (02.05) GB


3–116 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2235 Spindle %d is not a slave. SCPO (SpCouplePos- Please check your part Part program Reset of current
Offset) is only available program. error channel
for slave spindles.
2236 Spindle couple %d: Changing test mode de- Rebuild the spindle cou- Part program in the Info dia-
Changing test mode de- activates a spindle cou- ple. warning log with softkey
activates Couple. pling. ”Delete warn-
ings”
2237 Spindle couple %d: Mas- The programmed spindle Please modify the part Part program Reset of current
ter index is not allowed does not exist or this program. error channel
spindle is not a SERCOS-
spindle (Macoda 1040
0000 1).
2238 Spindle couple %d: No All couple members need If possible select a suit- Part program Reset of current
common speed range. a common speed range. able gear for each error channel
spindle.
2239 %s-Axis is not program- Axis belongs to an axis Axis is programmable in Part program Reset of current
mable in channel %d group of another channel. another channel. error channel
It cannot be programmed
in this channel.
2240 Geometry corrections not Geometry corrections are Please start program in a Part program Reset of current
existing for Aux-Chan- always assigned to a production channel. error channel
nels/CPL-Channels. fixed production channel.
2241 Index for external correc- Internal error Please call for Bosch ser- Part program Reset of current
tion group is not valid! vice! error channel
2242 Direction index for ext. Internal error Please call for Bosch ser- Part program Reset of current
length correction is not vice! error channel
valid!
2243 Index for external correc- Internal error Please call for Bosch ser- Part program Reset of current
tion group is not valid! vice! error channel
2244 Wrong type for group 1 The correction type of the Please transfer external Part program Reset of current
external correction data. actual external correction correction data with same error channel
data does not conform to correction type as fixed in
the correction type fixed MACODA or change MA-
in MACODA. CODA’s correction type.
2245 Wrong type for group 2 The correction type of the Please transfer external Part program Reset of current
external correction data. actual external correction correction data with same error channel
data does not conform to correction type as fixed in
the correction type fixed MACODA or change MA-
in MACODA. CODA’s correction type.
2246 Drill Axis: Invalid correc- Only correction groups 1 Please program CG1 for Part program Reset of current
tion group programmed. and 2 exist. correction group 1 or error channel
CG2 for correction group
2.
2247 More than 8 axis config- Maximum of 8 axes can Please change your set- Part program Reset of current
ured in one channel. be assigned to one chan- tings for MACODA pa- error channel
nel. rameter 1003 0000 2.
2248 L1 correction assigned to Only one correction value Assign maximum of 1 Part program Reset of current
an axis with other correc- is allowed for each axis. correction to each axis. error channel
tion.
2249 L2 correction assigned to Only one correction value Assign maximum of 1 Part program Reset of current
an axis with other correc- is allowed for each axis. correction to each axis. error channel
tion.
2250 L3 correction assigned to Only one correction value Assign maximum of 1 Part program Reset of current
an axis with other correc- is allowed for each axis. correction to each axis. error channel
tion.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–117

No Error text Cause Correction Error class Reset mode


2251 H correction is assigned Only one correction value Assign maximum of 1 Part program Reset of current
to an axis with other is allowed for each axis. correction to each axis. error channel
correction.
2252 The H correction is as- A different tool correction Please assign no more Part program Reset of current
to signed to at least 2 axes! must be assigned to each than one correction direc- error channel
2253 axis. tion to a channel axis.
2254 The L1 correction is as- A different tool correction Please assign no more Part program Reset of current
to signed to at least 2 axes! must be assigned to each than one correction direc- error channel
2255 axis. tion to a channel axis.
2256 The L2 correction is as- A different tool correction Please assign no more Part program Reset of current
to signed to at least 2 axes! must be assigned to each than one correction direc- error channel
2257 axis. tion to a channel axis.
2258 The L3 correction is as- A different tool correction Please assign no more Part program Reset of current
to signed to at least 2 axes! must be assigned to each than one correction direc- error channel
2259 axis. tion to a channel axis.
2260 Invalid value for argument Valid input for argument Please program a valid Part program Reset of current
<select> (command TC). <select>: 1=L3/H correc- value. error channel
tion, 2=radius, 3=L1
correction, 4=L2 correc-
tion, 5=orientation,
6=correction type.
2261 TCP/IP: can’t open ether- No access to the Ethernet No error recovery pos- Interface warn- in the Info dia-
net device. Device. Can’t initialize the sible! ing log with softkey
hardware. Causes: hard- ”Delete warn-
ware problem, or not ings”
enough dynamic memory.
2262 TCP/IP: Error %d at Error during startup of No error recovery pos- Serious system System Restart
startup of TCP/IP. TCP/IP. Network commu- sible! error
nication is impossible. For
a detailed error descrip-
tion the parameter refers
to the error number in the
wera database.
2263 No Pointer for KNS ac- APS task could not deter- Check entries in module Minor system System Restart
cess %d. mine pointer to KNS init kns_main.c. error
and KNS main function.
2264 Punching is not activated. Punching can be used in Modify the indicated MA- Part program Reset of current
the NC program only if it CODA parameter and ini- error channel
is applicated in MA- tiate a new system
CODA. startup.
2265 Error on opening file Axis coupling couldn’t No error recovery pos- Part program Reset of current
to ”%s”. Errno= %d. open the indicated spline- sible! error channel
2266 or coupling-table file
file, as
the function fopen re-
turned an error.
2267 Spindle %d: Reference A position controlled The reference point can Part program Reset of current
point is unknown. spindle needs to know be approached by spindle error channel
the c-axis reference point orientation (M19) in
for spindle orientation and speed controlled spindle
spindle coupling. mode.
2268 Spindle %d is no internal This function is only for No error recovery pos- Part program Reset of current
spindle. SERCOS and analog sible! error channel
spindles available.
2269 Internal error of axis con- Control internal error in Please call your Bosch Part program Reset of current
figuration (usr data not axis assignment tables. service error channel
free)

1070 073 799-102 (02.05) GB


3–118 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2270 Programmed axis classifi- Following axis classifica- Please program a valid Part program Reset of current
cation not valid! tions are allowed: 1, 2, 3, value for axis classifica- error channel
10, 20, 30, 100, 200, 300, tion.
999.
2271 A certain classification is With exception of classifi- Please assign the axis Part program Reset of current
programmed at least cation 999 all other axis classifications 1, 2, 3, 10, error channel
twice. classification should only 20, 30, 100, 200 and 300
be assigned a maximum a maximum of once per
of once per channel. channel.
2272 No write access on this There is no access with Use another file system Part program Reset of current
file system possible CPL commands to the file or change the access error channel
system because of miss- rights of the file system.
ing access rights.
2273 Area monitoring: Inadmis- The value of at least one Correct the MACODA Part program Reset of current
sible system axis number of the MACODA parame- value. error channel
for area %d. ters 800200001 or
800200002 doesn’t corre-
spond to a valid system
axis number.
2274 Area monitoring: Area %d The MACODA-Value Correct the MACODA Part program Reset of current
has no valid type. 800200031 doesn’t corre- value. error channel
spond to an admissible
area type. Admissible are
the values 1 and 2.
2275 System axis %d position On activating a working Deactivate the area and Part program Reset of current
beyond area %d area, the axes are al- drive the axes to allowed error channel
ready positioned beyond positions or adapt the
this area. area.
2276 Area monitoring: Inadmis- The area index pro- Correct the faulty part Part program Reset of current
sible area index %d. grammed with one of the program. error channel
syntax elements AREA-
DEF() or AREAVALID()
exceeds the allowed
range. The allowed range
lies between 0 and the
number of elements
created in MACODA pa-
rameter 800200031.
2277 Area monitoring: System The attempt to program Either modify the NC pro- Part program Reset of current
axes for area %d not in an area failed because gram or adapt the param- error channel
the active channel. the system axis dimen- eters (800200001,
sions of this area that are 80020002) in MACODA
adjusted in MACODA and restart the system.
(800200001, 800200002)
don’t belong to the active
channel.
2278 Area monitoring: Actual- Reading the actual Posi- No error recovery pos- Part program Reset of current
Positions can’t be read. tions wasn’t successful sible! error channel
after several attempts be-
cause the interpolation in-
terrupt interrupted the
reading Task each time.
2279 Area monitoring: More More than one axis is Jog the axes separately. Part program Reset of current
than one axis is jogged. jogged while a dead area error channel
is active. Area monitoring
is No error recovery pos-
sible!.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–119

No Error text Cause Correction Error class Reset mode


2280 System axis %d position On activating a working Deactivate the area and Part program Reset of current
beyond area %d area, the axes are al- drive the axes to allowed error channel
ready positioned beyond positions or adapt the
this area. area.
2281 Area monitoring: Area %d AREADEF was called Modify part program. Part program Reset of current
has no valid type. with an invalid parameter error channel
2282 Area monitoring: Area %d An area reserved by Either use another area Part program Reset of current
to is reserved by channel another channel is ac- or perform a system error channel
2286 %d. cessed by programming startup.
one of the syntax ele-
ments AREADEF() or
AREAVALID(). An area
reserved by a channel will
only be released after
system startup.
2287 Area monitoring: Inadmis- The area index pro- Correct the faulty part Part program Reset of current
sible area index %d. grammed with one of the program. error channel
syntax elements AREA-
DEF() or AREAVALID()
exceeds the allowed
range. The allowed range
lies between 0 and the
number of elements
created in MACODA pa-
rameter 800200031.
2288 Tangential tool guidance: The tool axis within the Please check and modify Part program Reset of current
Tool axis not in channel. NC function ”tangential the part program. error channel
tool guidance” doesn’t be-
long to the actual chan-
nel. This can have two
reasons: 1. An inadmissi-
ble tool axis was pro-
grammed. 2. No tool axis
was programmed and the
default tool axis in MA-
CODA doesn’t belong to
the actual channel.
2289 System axis %d position Axis monitoring: Axis has Jog axis in opposite di- Part program in the Info dia-
to on limit of area been jogged to the limit of rection. warning log with softkey
2291 an area. ”Delete warn-
ings”
2292 System axis %d position On activating a dead Deactivate the area and Part program Reset of current
to in area %d area, axes are already drive the axes to allowed error channel
2293 positioned in this area. positions or adapt the
area.
2294 Axis transfer: an axis par- Axes must hold their Please examine your part Part program Reset of current
ticipating in coordinate place in axes configura- program. error channel
rotation has changed its tion while they’re part of a
configuration. coordinate rotation.
2295 Axis transfer: an axis par- Axes must hold their Please examine your part Part program Reset of current
ticipating in datum point place in axes configura- program. error channel
rotation has changed its tion while they’re part of a
configuration. rotation of datum point.
2296 Axis transfer: axis trans- While an inclined plane is Please examine your part Part program Reset of current
fer is not allowed while an active, the channel axis program. error channel
inclined plane is active. configuration should not
be changed.

1070 073 799-102 (02.05) GB


3–120 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2297 Internal error: Too many The block processing unit Please call your Bosch Part program Reset of current
axes for return to path! tries to return to path for service team. error channel
more axes than config-
ured in the actual chan-
nel.
2298 Internal configuration er- After each new axis con- Please call your Bosch Part program Reset of current
ror: Axis missing in chan- figuration the axis confi- service team. error channel
nel axis list! gurator generates a
packed axis structure. In-
side of this structure an
invalid missing axis was
detected.
2299 Internal error: Not enough While leaving the pro- Please program a valid Part program Reset of current
memory for storing of ge- grammed contour, geom- value for axis classifica- error channel
ometry data. etry of the actual block tion.
will be stored inside block
data. The reserved size
of memory in not suffi-
cient for the active geom-
etry type.
2300 An invalid value for sym- For symmetry of tangen- Please program a valid Part program Reset of current
metry has been pro- tial tool orientation only value for symmetry of error channel
grammed. some special inputs are tangential tool orientation.
valid (please look at your
programming manual).
2301 Programmed offset angle The valid range of the Check your part program. Part program Reset of current
is not valid. tangential tool orientation error channel
is from >-180 up to <=180
Degrees.
2302 Internal error: no correc- While leaving the pro- Please program a valid Part program Reset of current
tion method for actual grammed contour the value for axis classifica- error channel
block available. milling tool correction tion.
must be inverted. For the
actual block no evaluation
instructions exist.
2303 Axis transfer: Coupled An axis of an axis union De-couple axis before Part program Reset of current
axis %d is missing in has been discarded from axis transfer. error channel
channel. the actual channel by the
function ”axis transfer”.
2304 Tangential tool guidance: The orientation axis of Switch off tangential tool Part program Reset of current
Tool axis %d not any tangential tool guidance guidance before the axis error channel
more in channel. was removed from the transfer.
actual channel by the
function axis transfer.
2305 Error on opening file Axis coupling couldn’t No error recovery pos- Part program Reset of current
”%s”. Errno= %d. open the indicated spline- sible! error channel
or coupling-table file, as
the function fopen re-
turned an error.
2306 Error closing file ”%s”. Function fclose returned No error recovery pos- Part program Reset of current
an error. sible! error channel
2307 General read error in file An error occurred during No error recovery pos- Part program Reset of current
”%s”. reading the number of sible! error channel
splines.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–121

No Error text Cause Correction Error class Reset mode


2308 Because of G76 incre- Inconsistent program- Please program axis with Part program Reset of current
mental programming for ming: an explicit incre- its logical axis name and error channel
%s-axis is not allowed. mental programming by without any attribute.
using ...I (e.g. XI) or the
IC( ) attribute is not al-
lowed together with G76.
2309 Area monitoring: Inadmis- The area index pro- Correct the faulty part Part program Reset of current
sible area index %d. grammed with one of the program. error channel
syntax elements AREA-
DEF() or AREAVALID()
exceeds the allowed
range. The allowed range
lies between 0 and the
number of elements
created in MACODA pa-
rameter 800200031.
2310 Area monitoring: Area %d AREADEF was called Modify part program. Part program Reset of current
has no valid type. with an invalid parameter error channel
2311 Area monitoring: System The attempt to program Either modify the NC pro- Part program Reset of current
to axes for area %d not in an area failed because gram or adapt the param- error channel
2312 the active channel. the system axis dimen- eters (800200001,
sions of this area that are 80020002) in MACODA
adjusted in MACODA and restart the system.
(800200001, 800200002)
don’t belong to the active
channel.
2313 Area monitoring: Second The attempt to program Either modify the NC pro- Part program Reset of current
parameter is wrong or an area failed because gram or adapt the param- error channel
missing the system axis dimen- eters (800200001,
sions of this area that are 80020002) in MACODA
adjusted in MACODA and restart the system.
(800200001, 800200002)
don’t belong to the active
channel.
2314 Area monitoring: Axis of An active area shall be Deactivate the concern- Part program Reset of current
area %d not in channel monitored whereas its di- ing areas. error channel
mensions do not belong
to the channel.
2315 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
tem NCS (detail codes sible! error
%d %d)
2316 Area monitoring: Inadmis- The area index pro- Correct the faulty part Part program Reset of current
to sible area index %d. grammed with one of the program. error channel
2317 syntax elements AREA-
DEF() or AREAVALID()
exceeds the allowed
range. The allowed range
lies between 0 and the
number of elements
created in MACODA pa-
rameter 800200031.
2318 Axes of area %d are not A monitoring area shall Reference the axes first . Part program Reset of current
referenced be activated, whose ap- error channel
propriate system axes are
not referenced.
2319 gantry axis %d pro- Gantry axis may not be Modify the part program. Part program Reset of current
grammed as a slave axis programmed as a slave. error channel

1070 073 799-102 (02.05) GB


3–122 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2320 Gantry homing: Input sig- The input signal ”jog axis” Modify the PLC program. Part program Reset of current
nal ”Axis inhibit” misses for homing must not be error channel
for axis %d set before the signal
”feed hold” is set.
2321 Gantry homing: Homing In the SERCOS files The parameter S-0-0147 Part program Reset of current
parameters for axes are p3lin*.scs the bit 7 of pa- of the axes must be error channel
different, master axis %d rameter S-0-0147 is dif- adapted in the concerning
ferent for several axes. SERCOS-Files p3lin*.scs
and a
SERCOS startup must be
performed.
2322 Gantry homing: Input sig- The input signal ”jog axis” Modify the PLC program. Part program Reset of current
nal ”Axis inhibit” misses for homing must not be error channel
for axis %d set before the signal
”feed hold” is set.
2323 Gantry homing: SERCOS Homing has been Perform control reset. If Servo loop or Reset of current
to error for axis %d stopped by the drive due necessary perform sys- drive fault channel
2324 to an error. tem or SERCOS startup.
2325 Gantry couple: Torque The maximum value for Perform control reset. If Servo loop or Reset of current
limit exceeded, master the torque summary of all necessary perform sys- drive fault channel
axis %d axes, adjusted in MA- tem or SERCOS startup.
CODA, is exceeded.
2326 Gantry axes: startup error During system startup Correct the SERCOS pa- Servo loop or NCS_WEA_SE
one of the following errors rameter S-0-0147 in the drive fault RCOSRE-
occurred: The homing pa- file p3lin*.scs if necessary SET_C
rameters of several axes and perform a system
are different (SERCOS startup or SERCOS
parameter S-0-0147 Bit startup.
7). The actual positions of
the axes could not be
read from SERCOS be-
cause SERCOS startup
failed.
2327 Stroke monitoring: Stroke After stroke release the Check punch control and Part program in the Info dia-
has not been released. acknowledge ”stroke cables to the DCIO. warning log with softkey
runs” wasn’t received ”Delete warn-
within the time fixed in ings”
MACODA.
2328 Stroke monitoring: Stroke The stroke was not fin- Check punch control and Part program in the Info dia-
has not been finished. ished within the time fixed cables to the DCIO. warning log with softkey
in MACODA, i.e. the 0-1 ”Delete warn-
change of the fast input ings”
signal ”Stroke doesn’t
run” was missing.
2329 Gantry homing: Homing Homing has not been If the digital outputs are Part program Reset of current
to not activated for axis %d started simultaneously for not handled correctly error channel
2330 all axes of a gantry bond. modify the PLC program.
Check whether the axes
are reserved by different
channels. In this case NC
cycles and NC program
have to be modified.
2331 %s-Axis cannot be in- The programmed axis Modify part program. Part program Reset of current
to serted in channel name cannot determine error channel
2332 an axis.
2333 Invalid axis name Programmed axis name Modify part program. Part program Reset of current
starts neither with a num- error channel
ber nor a letter.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–123

No Error text Cause Correction Error class Reset mode


2334 Invalid axis name %s The programmed axis Modify part program. Part program Reset of current
name cannot determine error channel
an axis.
2335 Invalid axis number %d The programmed axis Modify part program. Part program Reset of current
number cannot determine error channel
an axis.
2336 %s-Axis cannot be re- The programmed axis Modify part program. Part program Reset of current
to moved from channel name cannot determine error channel
2337 an axis.
2338 asynchronous axis pro- Programming G590 a Correct the part program Part program Reset of current
grammed as slave slave axis was selected or assign the axis to the error channel
that doesn’t belong to the concerning channel.
active channel.
2339 Error in the %d-th entry of The machine simulation Use tool SimuDat to read Minor system System Restart
type %s in the machine file is wrong. and correct the machine error
simulation file %s. simulation file.
2340 Machine simulation: No Not enough memory to No error recovery pos- Minor system System Restart
memory for buffer %s. interpret the machine sible. Please call your error
simulation file. Bosch service.
2341 No valid entry in the ma- The machine simulation Use tool SimuDat to read Minor system System Restart
chine simulation file %s. file is empty or doesn’t and correct the machine error
contain valid line types. simulation file.
2342 Gantry couple: slave axis A slave axis doesn’t be- Check whether the axes Part program Reset of all
%d in wrong channel long to the same channel of a pair are assigned to error channels in
as the master axis. Each different channels in MA- ”DIAGNOS-
slave axis must be as- CODA. If not, check TICS” group op-
signed to the same chan- whether an axis is as- erating mode
nel as the master axis or signed to another channel
it must be assigned to no by an NC program. Cor-
channel. If the master rect the program.
axis isn’t assigned to a
channel, the slave axes
also must not be as-
signed to a channel. A
gantry axis that isn’t as-
signed to a channel in
MACODA must not be
assigned to a channel in
an NC program.
2343 No memory for automatic The automatic program No error recovery pos- Minor system in the Info dia-
program re-selection. re-selection cannot be ac- sible! error log with softkey
tivated because there is ”Delete warn-
not sufficient channel me- ings”
mory available.

1070 073 799-102 (02.05) GB


3–124 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2344 Gantry couple: slave axis A slave axis doesn’t be- Check whether the axes Part program System Restart
%d in wrong channel long to the same channel of a pair are assigned to error
as the master axis. Each different channels in MA-
slave axis must be as- CODA. If not, check
signed to the same chan- whether an axis is as-
nel as the master axis or signed to another channel
it must be assigned to no by an NC program. Cor-
channel. If the master rect the program.
axis isn’t assigned to a
channel, the slave axes
also must not be as-
signed to a channel. A
gantry axis that isn’t as-
signed to a channel in
MACODA must not be
assigned to a channel in
an NC program.
2345 Gantry couple: slave axis A slave axis doesn’t be- Check whether the axes Part program Reset of current
to %d in wrong channel long to the same channel of a pair are assigned to error channel
2347 as the master axis. Each different channels in MA-
slave axis must be as- CODA. If not, check
signed to the same chan- whether an axis is as-
nel as the master axis or signed to another channel
it must be assigned to no by an NC program. Cor-
channel. If the master rect the program.
axis isn’t assigned to a
channel, the slave axes
also must not be as-
signed to a channel. A
gantry axis that isn’t as-
signed to a channel in
MACODA must not be
assigned to a channel in
an NC program.
2349 Software limit range ex- An axis coordinate has Select a motion that Part program Reset of current
to ceeded in axis %s! been programmed which doesn’t exceed the axis error channel
2352 violates the software travel limit.
travel limits defined in
MACODA.
2353 Motion for system axis The programming yields Select a motion that Part program Reset of current
%s greater/equal 360 de- a motion of more than doesn’t exceed the axis error channel
grees. 360 degrees for a modulo travel limit.
rotary axis.
2354 Drive Off for system axis For a moving axis the in- Check the PLC-program. Part program Reset of current
%s! terface signal ”Drive Off” Continue is possible with error channel
was set. control reset.
2355 Drive Inhibit for system For a moving axis the in- Speed has been pro- Part program Reset of current
axis %s! terface signal ”Drive In- grammed for a spindle error channel
hibit” has been set. without a selected gear.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–125

No Error text Cause Correction Error class Reset mode


2356 Endless position mode is It is only possible to pro- Modify part program cor- Part program Reset of current
not switchable for axis gram endless axes (MA- responding to the MA- error channel
%s! CODA parameter CODA parameter or cor-
100300004 ”axis move- rect MACODA parameter.
ment type”) with G151
when MACODA parame-
ter 100300005 ”endless
axes positioning logic”
and 100300050 ”switch of
endless axis positioning
logic” are set in the right
way. Only the values 0, 1,
2 are possible (see
100300005).
2357 Invalid endless position It is only possible to pro- Modify part program cor- Part program Reset of current
mode for axis %s! gram endless axes (MA- responding to the MA- error channel
CODA parameter CODA parameter or cor-
100300004 ”axis move- rect MACODA parameter.
ment type”) with G151
when MACODA parame-
ter 100300005 ”endless
axes positioning logic”
and 100300050 ”switch of
endless axis positioning
logic” are set in the right
way. Only the values 0, 1,
2 are possible (see
100300005).
2358 Slave axis %s is located An axis that lies in the se- Please modify the part Part program Reset of current
in the selected plane. lected plane may not be program. error channel
programmed as a slave
axis.
2359 Axis type of slave axis The axis type of the pro- Please modify the part Part program Reset of current
%s not allowed. grammed slave axis is program. error channel
not identical with type of
the master axis.
2360 Axis coupling: Slave axis Slave axis of a couple Please modify the part Part program Reset of current
%s is member of another may not be programmed program. error channel
couple. as slave axis of another
couple.
2361 Axis coupling: Master There was an attempt to Please modify the part Part program Reset of current
axis and slave axis %s program a master axis as program. error channel
are identical. a slave axis.
2363 Couple lag for system The difference of actual Check the axis’ dynamic. Part program Reset of current
axis %s exceeded. positions of two coupled If necessary adjust the error channel
axes exceeds the permis- values for monitoring in
sible maximum. The axis MACODA . Perform con-
which has a larger dis- trol reset. If necessary
tance to the common perform system or SER-
commanded position is COS startup.
indicated as the faulty
axis.
2364 Programmed acceleration Programmed acceleration Program a value less Part program Reset of current
is too large for %s axis! must be less than the than the corresponding error channel
MACODA parameter MACODA value.
value.
2365 Drive error for coupled The drive of a coupled Perform control reset. If Servo loop or Reset of current
system axis %s. axis announced a SER- necessary perform sys- drive fault channel
COS error. tem or SERCOS startup.

1070 073 799-102 (02.05) GB


3–126 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2366 System axis %s: Wrong Wrong axis operation Adjust another axis op- Part program Reset of current
axis mode active. mode by interface input. eration mode on the axis error channel
interface input.
2367 System axis %s is used An asynchronous axis Stop the asynchronous Part program Reset of current
by another channel. started by another chan- axis with channel control error channel
nel is still moving. reset.
2368 Not enough memory for There is not enough me- If CC-functions are used Part program in the Info dia-
the declaration of CC- mory for the declaration in the knb software, re- warning log with softkey
functions. of CC-functions via the port the error to the after ”Delete warn-
opi interface. sales service of the NC ings”
manufacturer. The error
can be ignored, if no CC-
functions are used.
2369 System axis %s has al- The asynchronous axis Modify the part program. Part program Reset of current
ready been started asyn- has already been started A new start can only be error channel
chronously . by this channel and executed when the axis
hasn’t reached its end has stopped.
position.
2370 axis %s: Axis coupling is A Hirth axis is selected as Please check the part Part program Reset of current
No error recovery pos- a master of a coupling. program. error channel
sible! with a hirth axis.
2371 System axis %s: hand- A hirth axis can not be Traverse this axis by us- Part program Reset of current
wheel mode is No error moved by a handwheel. ing the jog mode. error channel
recovery possible! with a
hirth axis.
2372 Axis %s: The Inclined One of the first three Please modify your part Part program Reset of current
plane function cannot be channel axes is a hirth program. error channel
used in combination with axis.
a Hirth axis.
2373 System axis %s has An axis has been driven Move the axis off the Part program in the Info dia-
reached travel limit! to its travel limits by using travel limits in opposite di- warning log with softkey
jog mode. rection. ”Delete warn-
ings”
2374 Commanded incremental The selected incremental Select a motion that Part program in the Info dia-
jog movement (system motion would exceed the doesn’t exceed the axis warning log with softkey
axis %s) would increase axis travel limit. travel limit. ”Delete warn-
the travel limits! ings”
2375 Synchronous axis of Therefore axis cannot be Execute control reset. Part program Reset of current
channel %d is temporary reserved. Attention: This will stop error channel
drive interpolated. the drive controlled axis
interpolation.
2376 System axis %s is tempo- In this state the axis can- The axis must be Part program Reset of current
rary drive interpolated. not be jogged. switched to NC controlled error channel
interpolation.
2377 Slave axis %s is already A master axis may not be Delete first the axis union Part program Reset of current
master axis of another used as slave axis in of the programmed axis error channel
axis union. another axis union. in the NC program. The
slave axis can then be
programmed.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–127

No Error text Cause Correction Error class Reset mode


2378 Couple factor and modulo A coupling of modulo Adjust the coupling factor Part program Reset of current
values of axes %s and axes via a linear coupling or the axis modulo values error channel
%s don’t match. relation requires that the (MACODA parameter).
modulo values Mm and
Ms of the master and the
slave axis respectively
obey the equation Mm*k
mod Ms = 0, where k is
the programmed coupling
factor.
2379 Inadmissible coupling of It is No error recovery Define master axis as Part program Reset of current
non-modulo axis %s to possible! to couple a non- non-modulo axis in MA- error channel
modulo axis %s. modulo axis to a modulo CODA or perform cou-
axis via a linear coupling pling via a coupling table.
relation.
2380 Coupling table of slave The master axis is a lin- Change value at the indi- Part program Reset of current
axis %s is not suited for ear axis. The x-values of cated ident number in the error channel
linear master axis %s. the points in the coupling coupling table.
table still have an angular
unit (ident number #11).
2381 Coupling table of slave The master axis is a Change value at the indi- Part program Reset of current
axis %s is not suited for rotary axis. The x-values cated ident number in the error channel
rotary master axis %s. of the points in the cou- coupling table.
pling table still have a
length unit (ident number
#11).
2382 Wrong period in coupling The master axis is a mo- Change period (x-value of Part program Reset of current
table for slave axis %s dulo axis with modulo last point) in the coupling error channel
and master axis %s. value Mm (drive parame- table.
ter). The period p in the
coupling table must there-
fore obey the equation
Mm mod p = 0.
2383 Inadmissible non-periodic The master axis is a mo- Change value at the indi- Part program Reset of current
function in coupling table dulo axis. The function in cated ident number in the error channel
for slave axis %s and the coupling table must coupling table.
master axis %s. therefore be periodic (id-
ent number #20 1).
2384 Programmed coupling A motion of the master Change programmed Part program Reset of current
to relation for slave axis %s axis over the total defini- coupling relation or the error channel
2387 is not consistent with first tion range of the coupling values in the coupling
negative travel limit. table would lead to a table.
slave axis motion reach-
ing its first negative travel
limit.

1070 073 799-102 (02.05) GB


3–128 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2388 Valid dynamic limit for An axis coupling via a Perform a dry run with re- Part program Reset of current
master axis %s not found. coupling table with cubic duced feed rate before warning channel
spline interpolation be- the final machining.
tween the points leads to
an additional acceleration
(radial acceleration) of
the slave axis. In order to
keep the slave axis accel-
eration below its MA-
CODA value the master
axis maximum velocity as
well as its acceleration
must be decreased. The
internal algorithm didn’t
find a valid solution.
2389 Slave axis %s has a zero A coupling table with lin- Define a velocity step Part program Reset of current
maximum velocity step ear interpolation between change for the indicated error channel
change. the points leads to veloc- slave axis in MACODA or
ity step changes of the use cubic spline inter-
slave axis if the master polation in the coupling
axis moves with constant table.
velocity. Therefore the
maximum velocity of the
master axis is reduced so
that the slave axis doesn’t
exceed its maximum ve-
locity step change (MA-
CODA parameter). A zero
step change of the slave
axis wouldn’t therefore al-
low any motion of the
master axis.
2390 Inadmissible motion for In the NC program a mo- Please check and modify Part program Reset of current
slave axis %s. tion was programmed for the part program. error channel
a coupled axis. This is not
allowed.
2391 Illegal tool axis %s. The tool axis doesn’t exist Correct tool axis number Part program Reset of current
or is part of the working in part program or in MA- error channel
plane. CODA parameter
705000210.
2392 Wrong axis type for se- The tool axis type in part Modify the axis type or Part program Reset of current
lected tool axis %s. program or in MACODA select another tool axis. error channel
parameter 705000210 is
not rotary or endless.
2393 System axis %s position Axis monitoring: Axis has Jog axis in opposite di- Part program in the Info dia-
on limit of area been jogged to the limit of rection. warning log with softkey
an area. ”Delete warn-
ings”
2394 System axis %s position On activating a dead Deactivate the area and Part program Reset of current
in area %d area, axes are already drive the axes to allowed error channel
positioned in this area. positions or adapt the
area.
2395 System axis %s position On activating a working Deactivate the area and Part program Reset of current
beyond area %d area, the axes are al- drive the axes to allowed error channel
ready positioned beyond positions or adapt the
this area. area.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–129

No Error text Cause Correction Error class Reset mode


2396 Axis transfer: Coupled An axis of an axis union De-couple axis before Part program Reset of current
system axis %s is miss- has been discarded from axis transfer. error channel
ing in channel. the actual channel by the
function ”axis transfer”.
2397 Tangential tool guidance: The orientation axis of Switch off tangential tool Part program Reset of current
Tool system axis %s not tangential tool guidance guidance before the axis error channel
any more in channel. was removed from the transfer.
actual channel by the
function axis transfer.
2398 gantry system axis %s Gantry axis may not be Modify the part program. Part program Reset of current
programmed as a slave programmed as a slave. error channel
axis
2399 ”Gantry homing: Input The input signal ”jog axis” Modify the PLC program. Part program Reset of current
signal ””Axis inhibit”” for homing must not be error channel
misses for system axis set before the signal
%s” ”feed hold” is set.
2400 Gantry homing: Homing In the SERCOS files The parameter S-0-0147 Part program Reset of current
parameters for axes are p3lin*.scs the bit 7 of pa- of the axes must be error channel
different, master: system rameter S-0-0147 is dif- adapted in the concerning
axis %s ferent for several axes. SERCOS-Files p3lin*.scs
and a
SERCOS startup must be
performed.
2401 Gantry homing: SERCOS Homing has been Perform control reset. If Servo loop or Reset of current
error for system axis %s stopped by the drive due necessary perform sys- drive fault channel
to an error. tem or SERCOS startup.
2402 Gantry couple: Torque The maximum value for Perform control reset. If Servo loop or Reset of current
limit exceeded, master: the torque summary of all necessary perform sys- drive fault channel
system axis %s axes, adjusted in tem or SERCOS startup.
MACODA, is exceeded.
2403 Gantry homing: Homing Homing has not been If the digital outputs are Part program Reset of current
not activated for system started simultaneously for not handled correctly error channel
axis %s all axes of a gantry bond. modify the PLC program.
Check whether the axes
are reserved by different
channels. In this case NC
cycles and NC program
have to be modified.
2404 System axis %s cannot The programmed axis Modify part program. Part program Reset of current
be inserted in channel number cannot determine error channel
an axis.
2405 Invalid axis number %d The programmed axis Modify part program. Part program Reset of current
number cannot determine error channel
an axis.
2406 System axis %s cannot The programmed axis Modify part program. Part program Reset of current
be removed from channel number cannot determine error channel
an axis.

1070 073 799-102 (02.05) GB


3–130 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2407 Gantry couple: slave sys- A slave axis doesn’t be- Check whether the axes Part program Reset of current
tem axis %s in wrong long to the same channel of a pair are assigned to error channel
channel as the master axis. Each different channels in MA-
slave axis must be as- CODA. If not, check
signed to the same chan- whether an axis is as-
nel as the master axis or signed to another channel
it must be assigned to no by an NC program. Cor-
channel. If the master rect the program.
axis isn’t assigned to a
channel, the slave axes
also must not be as-
signed to a channel. A
gantry axis that isn’t as-
signed to a channel in
MACODA must not be
assigned to a channel in
an NC program.
2408 No motion in selected G5 needs programmed Please adapt your part Part program Reset of current
plane before G5 block. coordinates in the actual programme. error channel
working plane of the pre-
vious block.
2409 Stroke monitoring: Stroke At the time of stroke re- Check punch control and Part program in the Info dia-
cannot be released. lease by the NC the state cables to the DCIO. warning log with softkey
”stroke runs” was active, ”Delete warn-
i.e. the fast input signal ings”
”Stroke doesn’t run” had
the value 0.
2410 Spindle %d: SERCOS Drive controlled switching Bit 8 must not be set in Part program Reset of current
secondary operation (bit 8) must not be acti- S-0-0034. Hint: S-0-0034 error channel
mode 2 is wrong config- vated in S-0-0034. is localized in the SER-
ured. COS-file for phase 2.
2411 Spindle %d cannot oper- For use with position in- Bit 7 must be set in Part program Reset of current
ate with position interface terface, the weighting S-0-0076. Hint: S-0-0076 error channel
type for position data is localized in the SER-
(S-0-0076) must be set to COS-file for phase 2.
rotary with modulo for-
mat.
2412 Tangential tool guidance: The tool axis cannot be Please check and modify Part program Reset of current
Angle of tangent at start aligned tangentially at the the part program. error channel
point outside axis travel start point because the
limit. travel limits do not allow
it.
2413 Tangential tool guidance: The tool axis must cover Split circular block into Part program Reset of current
Range of tangent angle an angle range on the cir- two blocks, so that possi- error channel
for circular block exceeds cular segment which ex- bly at the split point a new
travel limit range. ceeds the travel limit orientation may occur.
range.
2414 Axis classification of a In MACODA (parameter Assign axis classifica- Part program in the Info dia-
channel axis is missing. no. 7010 0003 0) there is tions to all channel axes. warning log with softkey
an axis classification Note: The axis classifica- ”Delete warn-
missing for an channel tions of all axes in one ings”
axis. channel must be different.
2415 System axis %s position On activating a dead Deactivate the area and Part program Reset of current
in area %d area, axes are already drive the axes to allowed error channel
positioned in this area. positions or adapt the
area.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–131

No Error text Cause Correction Error class Reset mode


2416 System axis %s position On activating a working Deactivate the area and Part program Reset of current
beyond area %d area, the axes are al- drive the axes to allowed error channel
ready positioned beyond positions or adapt the
this area. area.
2417 axis %s: Axis coupling is A Hirth axis is selected as Please check the part Part program Reset of current
No error recovery pos- a slave of a coupling. program. error channel
sible! with a hirth axis.
2418 Programmed acceleration Error in part program. Program an acceleration Part program Reset of current
value 0 for %s axis not al- which is greater then error channel
lowed. zero.
2419 Programmed end point The programmed or cal- Please modify your part Part program Reset of current
for system axis %s axis is culated axis coordinates program. error channel
no hirth position. must be a hirth position.
2420 ”Gantry homing: Input The input signal ”jog axis” Modify the PLC program. Part program Reset of current
signal ””Axis inhibit”” for homing must not be error channel
misses for system axis set before the signal
%s” ”feed hold” is set.
2421 Gantry homing: Homing Homing has not been If the digital outputs are Part program Reset of current
not activated for system started simultaneously for not handled correctly error channel
axis %s all axes of a gantry bond. modify the PLC program.
Check whether the axes
are reserved by different
channels. In this case NC
cycles and NC program
have to be modified.
2422 Axis coupling: system The axis programmed as Please modify the part Part program Reset of current
axis %s not allowed. a slave axis doesn’t be- program. error channel
long to the concerning
channel.
2423 Coupling table unsuitable The slave axis is a linear Change value at the indi- Part program Reset of current
for linear slave axis %s. axis. The y-values of the cated ident number in the error channel
points in the coupling coupling table.
table still have an angular
unit (ident number #12).
2424 Coupling table unsuitable The slave axis is a rotary Change value at the indi- Part program Reset of current
for rotary slave axis %s. axis. The y-values of the cated ident number in the error channel
points in the coupling coupling table.
table still have a length
unit (ident number #12).
2425 Gantry couple: slave sys- A slave axis doesn’t be- Check whether the axes Part program Reset of current
tem axis %s in wrong long to the same channel of a pair are assigned to error channel
channel as the master axis. Each different channels in MA-
slave axis must be as- CODA. If not, check
signed to the same chan- whether an axis is as-
nel as the master axis or signed to another channel
it must be assigned to no by an NC program. Cor-
channel. If the master rect the program.
axis isn’t assigned to a
channel, the slave axes
also must not be as-
signed to a channel. A
gantry axis that isn’t as-
signed to a channel in
MACODA must not be
assigned to a channel in
an NC program.

1070 073 799-102 (02.05) GB


3–132 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2426 %s axis: Calculated end The programmed or cal- Please modify your part Part program Reset of current
point is not a hirth posi- culated axis coordinates program. error channel
tion. must be a hirth position.
2427 System axis %s: Refer- The reference point must Please reconfigure the Part program Reset of current
ence point is not a hirth be a hirth position. SERCOS-parameters. error channel
position.
2428 The actual maximum axis Hostlib version: Servo er- Please check the prob- Part program Reset of current
velocity of system axis ror! lem. Possible reasons are error channel
%s is higher than the MA- wrong contour vectors,
CODA parameter. endpoints or feed limits.
2429 The actual axis slope ac- No error recovery pos- Part program in the Info dia-
celeration of system axis sible! warning log with softkey
%s is higher than MA- ”Delete warn-
CODA value. ings”
2430 System axis %s position Axis monitoring: Axis has Jog axis in opposite di- Part program in the Info dia-
to on limit of area been jogged to the limit of rection. warning log with softkey
2431 an area. ”Delete warn-
ings”
2432 Gantry homing: SERCOS Homing has been Perform control reset. If Servo loop or Reset of current
error for system axis %s stopped by the drive due necessary perform sys- drive fault channel
to an error. tem or SERCOS startup.
2433 Following synchronous During control reset of a Release the indicated Part program Reset of current
axis of channel %d are channel it was detected axes or abort by system error channel
not enabled: %s. that the indicated axes control reset.
are occupied by other
channels.
2434 Following synchronous During insertion of an Release the indicated Part program Reset of current
axis of channel %d are axis in a channel it was axes or abort by system error channel
not enabled: %s. detected that the indi- control reset.
cated axis is occupied by
another channel.
2435 Following synchronous During program selection Release the indicated Part program Reset of current
axis of channel %d are or MDI it was detected axes or abort by system error channel
not enabled: %s. that the indicated axes control reset.
are occupied by other
channels.
2436 The tool record (sector: As long as the tool record Repeat the action that Core system in the Info dia-
%d, place: %d) is locked is locked from PLC, nei- leaded to this error. If the warning log with softkey
by the PLC. ther MMI nor CPL have a error still appears, the ”Delete warn-
write access to this re- PLC user program should ings”
cord. be checked.
2437 The file systems are not The memory pages of the No error recovery pos- Core system in the Info dia-
write protected in user file systems are not write sible! warning log with softkey
level by the MMU. protected in user level by ”Delete warn-
the MMU. The Page- ings”
Table is corrupted.
2438 Illegal parameter for Only (0) is a allowed Please check the part Part program Reset of current
SPGALL value for SPGALL. program. error channel
SPGALL(0) resets all
spindle groups to MACO-
DA-default.
2439 Spindle %d is no internal This function is only avail- Please modify your part Part program Reset of current
spindle. able for internal spindles. program. warning channel
2440 Spindle %d is not a Tapping is only possible Please modify your part Part program Reset of current
spindle/C-axis. with a spindle/C-axis. program. warning channel

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–133

No Error text Cause Correction Error class Reset mode


2441 Tapping: The channel has The sum of the active Before tapping release Part program Reset of current
only space for %d addi- channel axis and the se- unused axes with error channel
tional spindles. lected spindles exceeds G512( ) from the channel
the maximum axis num- and reload them after that
ber. with G511( ).
2442 Tapping: There is no For the tapping function Select needed spindles Part program Reset of current
spindle selected. you must select at least by using G532. E.g. G532 error channel
one spindle. CAX2 CAX4.
2443 Tapping: Only one spindle Add additional spindles Part program Reset of current
group can be selected. by programming G532 error channel
GRPx CAXn CAXm.
2444 Constant cutting velocity It is impossible to use in- Please use G97 in com- Part program Reset of current
is active. cremental speed pro- bination with G194. error channel
gramming and constant
cutting speed at the same
time.
2445 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
number of parameters CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2446 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
type of parameter CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2447 Syntax %s for polar angle Polar-coordinate pro- Adjust an allowed syntax Part program Reset of current
not admissible. gramming: The NC syn- in MACODA (800500001) error channel
tax of the angle is identi- and correct the part pro-
cal with the syntax of the grams.
specified axis. A pro-
grammed angle would be
conjugated to the axis.
2448 Runtime overrun in inter- The runtime of the inter- No error recovery pos- Serious system System Restart
polator interrupt polator interrupt routine is sible! error
longer than the interpola-
tion clock. There is a end-
less loop in the software.
2449 MACODA parameter %d The activation of this MA- Initiate a system startup. Part program Reset of current
can only be transferred CODA parameter re- error channel
with control startup. quires a startup of the
NC.
2450 Machine simulation: no The first line of the de- Open the description file Minor system System Restart
version entry in the de- scription file must contain with SpsSimu or use error
scription file. the version number of the another editor to insert
tool SpsSimu. the version number of
SpsSimu if you know it.
2451 Machine simulation : the The version number of Use the tool with the right Minor system System Restart
version number of the de- APS must be equal or version number. error
scription file is higher larger than the version
then the version number number of the tool
of the tool SpsSimu. SpsSimu
2452 System axis %s: Stand- The standstill torque Perform control reset. If Servo loop or Reset of current
still torque limit exceeded value as adjusted in MA- necessary perform sys- drive fault channel
CODA, is exceeded. tem or SERCOS startup.

1070 073 799-102 (02.05) GB


3–134 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2453 System error in subsys- Internal system error! No error recovery pos- Minor system Reset of all
tem DHS (error codes %d sible! error channels in
%d %d). ”DIAGNOS-
TICS” group op-
erating mode
2454 NC program %s does not A nonexistent part pro- Repeat program selection Part program Reset of current
exist gram has been selected with an existing program error channel
or a nonexistent sub pro- or correct the part pro-
gram has been called. gram.
2455 Spindle %d is no SER- This function is only avail- Part program Reset of current
COS spindle. able for SERCOS error channel
spindles.
2456 Error reading zero offset zero offset table nonexis- generate zero offset table Part program Reset of current
table tent or protected or verify protection error channel
2457 Zero offset table has bad The format of the zero If you open the zero off- Part program Reset of current
format offset table is wrong. Per- set table with the table error channel
haps it has been modified editor, the defective line
by a text editor. and column will be dis-
played. Correct this error
with a text editor.
2458 Zero offset table not read The zero offset table Correct the part program: Part program Reset of current
couldn’t be read. Perhaps Program only tables error channel
it is an old table for a dif- which belong to the corre-
ferent channel. sponding channel.
2459 Zero offset table inconsis- The option ’strict assign- Correct the part program: Part program Reset of current
tent with actual axis con- ment’ is set for this table, Activate a zero offset error channel
figuration but the table doesn’t fit to table which matches the
the actual axis configura- axis configuration. Even-
tion. tually the option ’strict as-
signment’ may be reset in
the table editor.
2460 Column %s is declared The column is declared Correct the zero offset Part program Reset of current
as circular axis in the as a circular axis in the table: Modify axis type of error channel
zero offset table. zero offset table, but it is the corresponding col-
a linear axis. umn.
2461 Column %s is declared The column is declared Correct the zero offset Part program Reset of current
as linear axis in the zero as a linear axis in the table: Modify axis type of error channel
offset table. zero offset table, but it is the corresponding col-
a circular axis. umn.
2462 Zero offset table inconsis- The option ’strict assign- Correct the part program: Part program Reset of current
tent with actual axis con- ment’ is set for this table, Activate a zero offset error channel
figuration but the table doesn’t fit to table which matches the
the actual axis configura- axis configuration. Even-
tion. tually the option ’strict as-
signment’ may be reset in
the table editor.
2463 Zero offset table inconsis- The selected table has an The table will be con- Part program Reset of current
tent with actual axis con- old format. It may be verted to the new format error channel
figuration used only if the actual after opening it in the
axis configuration is iden- table editor.
tical to the default config-
uration of this channel.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–135

No Error text Cause Correction Error class Reset mode


2464 Only %d blocks in block There is not enough me- Adjust the configuration in Part program System Restart
preparation. Memory for mory available to create MACODA parameter warning
total %d blocks lacks. the totally adjusted num- 706000110 for each
ber of blocks for block channel. The total num-
preparation of all chan- ber of blocks must be de-
nels. There is a total lack creased to the an-
of memory for the number nounced value.
of blocks as announced
in the warning. A config-
uration to keep the basic
functionality of the chan-
nel is implicitly estab-
lished by the system.
Functionalities that re-
quire more blocks will not
work.
2465 Axis transfer: maximum At most 8 axes can be Correct the part program Part program Reset of current
number of axes per chan- assigned to one channel. or remove an unused axis error channel
nel exceeded. of the concerning chan-
nel.
2466 SERCOS communication A SERCOS command Initiate a system startup. Servo loop or System Restart
error during referencing has not been responded drive fault
of %s-axis by the drive. The flow of
referencing is corrupted,
referencing is stopped for
the case of reliability.
2467 Storage available only for It is necessary to make The memory layout must Part program System Restart
%d channels. more memory available be changed. This can be warning
for the system, for exam- done either by hardware
ple, by decreasing the (more memory) or by
number of channels. software exchange.
2468 Parity error. Internal software error. No error recovery pos- Hardware error System Restart
sible!
2469 Error %d after call of Internal software error. No error recovery pos- Serious system System Restart
to PxMsgSend. sible! error
2470
2471 Error %d in the ethernet Internal software error. No error recovery pos- Serious system System Restart
driver. sible! error
2472 Task %s cannot be Internal system error! No error recovery pos- Serious system System Restart
installed. sible! error
2473 Invalid table property in Programming error at Correct programming er- Part program Reset of current
the CPL-command %s. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2474 Invalid kind of axis in the Programming error at Correct programming er- Part program Reset of current
CPL-command %s. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2475 Invalid channel number in Programming error at Correct programming er- Part program Reset of current
the CPL-command %s. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2476 Table name or table tem- Programming error at Correct programming er- Part program Reset of current
plate name in the CPL- CPL - command. Further ror. Select part program error channel
command %s too long. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.

1070 073 799-102 (02.05) GB


3–136 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2477 Table name in the CPL- Programming error at Correct programming er- Part program Reset of current
command %s already ex- CPL - command. Further ror. Select part program error channel
ists. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2478 Table template in the Programming error at Correct programming er- Part program Reset of current
CPL-command %s not CPL - command. Further ror. Select part program error channel
found. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2479 Format of table template Programming error at Correct programming er- Part program Reset of current
in the CPL-command %s CPL - command. Further ror. Select part program error channel
incorrect. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2480 Table in the CPL-com- Programming error at Correct programming er- Part program Reset of current
mand %s not found. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2481 Column identifier in the Programming error at Correct programming er- Part program Reset of current
CPL-command %s in- CPL - command. Further ror. Select part program error channel
valid. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2482 Column in the table in the Programming error at Correct programming er- Part program Reset of current
CPL-command %s not CPL - command. Further ror. Select part program error channel
found. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2483 Column in the CPL-com- Programming error at Correct programming er- Part program Reset of current
mand %s already exists CPL - command. Further ror. Select part program error channel
in the table. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2484 Operation in the CPL- Programming error at Correct programming er- Part program Reset of current
command %s in this table CPL - command. Further ror. Select part program error channel
format invalid. information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2485 Table in the CPL-com- Programming error at Correct programming er- Part program Reset of current
mand %s is active. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2486 %s-command with invalid Programming error at Correct programming er- Part program Reset of current
number of parameters CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2487 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
tem SIO (code lines %d sible! error
%d).
2488 Invalid file name. Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2489 Insufficient memory for Too large values for stack Reduce data ranges in Core system System Restart
data areas of CPL pro- and link table are defined MACODA parameter warning
grams in channel %d. in MACODA block num- 707000010 and initiate a
ber 707000010 ”Data new system startup.
areas for CPL programs”.
2490 Task stack overflow Internal software error. No error recovery pos- Serious system System Restart
sible! error

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–137

No Error text Cause Correction Error class Reset mode


2491 MACODA parameter %d The activation of this MA- Initiate a system startup. Part program System Restart
can only be transferred CODA parameter re- error
with control startup. quires a startup of the
NC.
2492 Area %d is not program- According to MACODA, Modify the part program Part program Reset of current
mable. the programmed area or change the definition of error channel
cannot be modified in a the indicated area in MA-
part program. CODA parameters.
2493 A system call at the host Occurs only at the hostlib No error recovery pos- Serious system System Restart
returned with error %d . in handler routines, when sible! error
a host system call sent
back an error. Check file-
name and access rights,
if it is a file system call
(open, close, read, write).
2494 Type of variable ”%s” in- Programming error at Correct programming er- Part program Reset of current
valid. CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2495 invalid Variable %s Programming error at Correct programming er- Part program Reset of current
CPL - command. Further ror. Select part program error channel
information in ”CPL Pro- again and start it again if
gramming Instructions”. necessary.
2496 Init error SERCOS asic ASIC register cannot be Change SNCI or ask for Hardware error System Restart
set BOSCH service
2497 Maximum length of SER- The length of MDT and Check ASIC version, take Minor system System Restart
COS telegram exceeded AT exceeds available SNCI with new ASIC or error
RAM of the asic reduce length of SER-
COS telegram
2498 No data transfer on PRO- Software PLC is not run- Check the slave address, Interface error System Restart
FIBUS DP, Software PLC ning because there is cur- check the master-data file
not running. rently no data exchange of the concerning DP
between DP-master and master, check the con-
DP-slave. Eventually the nection to the DP master,
DP-master is not running. check the state of the DP
There might be also an master!
invalid master parameter
set or an interrupted con-
nection.
2499 Invalid axis transforma- Coordinate programming Modify part program. Part program Reset of current
tion number %d. was activated with an in- error channel
valid axis transformation
number.
2500 The axis transformation The activated axis trans- Adjust the transformation Part program Reset of current
%d has the invalid trans- formation has a wrong type in MACODA. error channel
formation type %d. transformation type in
MACODA.
2501 NC function for the axis Internal software error. No error recovery pos- Part program Reset of current
transformation to be acti- sible! error channel
vated could not be in-
serted.
2502 Axis transformation: Sys- A member axis of an axis Modify part program. Part program Reset of current
tem axis %s not in chan- transformation is no lon- error channel
nel. ger in the actual channel.

1070 073 799-102 (02.05) GB


3–138 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2503 Axes transformation: The entry in axis assign- Adjust corresponding MA- Part program Reset of current
Configuration error in pa- ment (MACODA parame- CODA parameter. error channel
rameter axis assignment ter) must refer to a linear
[%d]. system axis.
2504 Axes transformation: The entry in axis assign- Adjust corresponding MA- Part program Reset of current
Configuration error in pa- ment (MACODA parame- CODA parameter. error channel
rameter axis assignment ter) must refer to a rotary
[%d]. system axis.
2505 Axes transformation: The Length 1 and 2 must Adjust corresponding MA- Part program Reset of current
Configuration error in pa- be greater than or equal CODA parameter. error channel
rameter ”Length and to zero.
angle parameters”.
2506 Axes transformation: Two entries in axis as- Adjust corresponding MA- Part program Reset of current
Configuration error in pa- signment (MACODA pa- CODA parameter. error channel
rameter axis assignment rameter) refer to the
[%d]. same system axis.
2507 Rotation axis has zero The programmed rotation Modify part program. Part program Reset of current
length. axis has zero length. error channel
2508 Orientation vector has The programmed orienta- Modify part program. Part program Reset of current
zero length. tion vector has zero error channel
length.
2509 Collinear start and end The programmed orienta- Modify part program. Part program Reset of current
orientation. tion vector is parallel or error channel
anti-parallel to the start
orientation vector. Hence
the rotation axis is unde-
fined.
2510 Rotation axis not pro- The orientation program- Modify part program. Part program Reset of current
grammed. ming with a rotation angle error channel
requires a programmed
rotation axis.
2511 Local data for NC-func- Internal software error. No error recovery pos- Part program Reset of current
tion not available. sible! error channel
2512 NC block couldn’t be in- Internal software error. No error recovery pos- Part program Reset of current
serted. sible! error channel
2513 5-axis transformation: The motion of the orienta- Insert a block without mo- Part program Reset of current
Contour transition is dis- tion vector through the tion after the WAIT block. error channel
continuous for axis %s. position (0,0,+-1) poten-
tially requires the inser-
tion of an adaptation
block with a pure rotation
axis motion. Probably due
to a WAIT the adaptation
block couldn’t be in-
serted.
2514 NC Function could not be The NC function NcfOr- No error recovery pos- Part program Reset of current
to inserted. MoOn couldn’t be in- sible! error channel
2515 serted.
2516 Timeout while waiting for The I/O signals pro- Check the signals and Part program Reset of current
digital I/O signals. grammed in wait com- check the program for warning channel
mand have not received consistency.
the rated values in the
given time.
2517 CPL expression not al- The programmed CPL Modify part program. Part program Reset of current
lowed while runtime. expression may not be in- error channel
terpreted during runtime.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–139

No Error text Cause Correction Error class Reset mode


2518 Lower software travel An axis coordinate has Check the programmed Part program Reset of current
limit of axis %s, travel been programmed which axis coordinates, or, nec- error channel
limit value: %f, axis posi- violates the software essary change the soft-
tion: %f travel limits defined in ware travel limits in MA-
MACODA. CODA.
2519 Upper software travel An axis coordinate has Check the programmed Part program Reset of current
limit of axis %s, travel been programmed which axis coordinates, or, nec- error channel
limit value: %f, axis posi- violates the software essary change the soft-
tion: %f travel limits defined in ware travel limits in MA-
MACODA. CODA.
2520 Threading: Internal inter- A non-threading block Error recovery: Insert a Part program Reset of current
polation error, Distance pass a piece of way on to no distance block (e.g. error channel
to go > 0 a threading block. N15 G1) in front of the
threading block. In addi-
tion please report this er-
ror to the after sales ser-
vice of the NC manufac-
turer.
2521 Threading: Internal inter- The conversion of a No error recovery pos- Part program Reset of current
polation error, Sqrt from passed distance into sible! error channel
a negative number. spindle revolutions failed.
2522 (C-axis-)Reference point Threading with a position Please switch to a speed Part program Reset of current
is missing. controlled spindle needs controlled spindle (G533 error channel
to know the spindle (c- SPC0) and reference the
axis) reference point. spindle by spindle orien-
tation.
2523 No position controlled For tapping operations Switch to a position con- Part program Reset of current
spindle using a position-con- trolled spindle (G533 error channel
trolled spindle, the posi- SPC1).
tion control of the spindle
first has to be activated.
2525 Main spindle stopped by Spindle reset stops – Part program Reset of current
reset. thread cutting. error channel
2526 Thread cutting: Fast re- – – Part program Reset of current
tract! warning channel
2527 The adjusted acceleration – If G533 DYN( , , ) is used Part program Reset of current
is not high enough. modify the part program. error channel
In the other case check
the adjusted acceleration
in MACODA parameters
7050006xx.
2528 Max. path velocity ex- The product of spindle Please use a lower Part program Reset of current
ceeded. speed and thread lead spindle speed for thread- error channel
exceeds the max. path ing.
velocity.
2529 Spindle speed is too high. The max. spindle speed Please use a lower Part program Reset of current
Upper limit: %d U/min. is limited to 0.48 rev/NC- spindle speed for thread- error channel
cycle. ing.
2530 Drive under control is Possible reasons are: - Part program Reset of current
missing. Drive off, Drive inhibit - error channel
No drive release -
DC1-error.

1070 073 799-102 (02.05) GB


3–140 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2531 Invalid value. Only 0, 1, SDOM Sx=0 switches to Please check the part Part program Reset of current
11 allowed. speed controlled spindle program. error channel
mode. SDOM Sx=1
switches to position con-
trolled spindle mode with
stop. SDOM Sx=11
switches to position con-
trolled spindle mode with-
out stop.
2532 Both parameters are nec- Both retraction parame- Please modify your part Part program Reset of current
essary. ters must be programmed program. error channel
together.
2533 Invalid value. Only 0 and SPC1 switches to posi- Please check the part Part program Reset of current
1 are allowed. tion controlled spindle program. error channel
mode. SPC0 switches to
speed controlled spindle.
2534 Invalid value. Only 0 and TCI1 sets the channel in- Please check the part Part program Reset of current
1 are allowed. terface signal ”Thread program. error channel
cycle active”. TCI0 resets
the signal.
2535 TPMxx: This value is not Information about valid Please check and modify Part program Reset of current
a valid thread program- values and its meaning the part program. error channel
ming mode . can be taken from the
DIN Programming
manual.
2536 Implicit retraction is a fea- You use the parameter R The thread programming Part program Reset of current
ture of CC220-compatible (retraction angle). mode is defined by MA- error channel
programming. CODA 705000600 [1] or
by G33 TPMxy.
2537 Only G8, G9 and G108 We recommend G8 G33. Please modify the part Part program Reset of current
allowed. program. error channel
2538 Axis transformation: Sys- A member axis of an axis Modify part program. Part program Reset of current
tem axis %s not in chan- transformation is no lon- error channel
nel. ger in the actual channel.
2539 Axes transformation: Two entries in axis as- Adjust corresponding MA- Part program Reset of current
Configuration error in pa- signment (MACODA pa- CODA parameter. error channel
rameter axis assignment rameter) refer to the
[%d]. same system axis.
2540 Axes transformation: The entry in axis assign- Adjust corresponding MA- Part program Reset of current
Configuration error in pa- ment (MACODA parame- CODA parameter. error channel
rameter axis assignment ter) must refer to a linear
[%d]. system axis.
2541 Axes transformation: The entry in axis assign- Adjust corresponding MA- Part program Reset of current
Configuration error in pa- ment (MACODA parame- CODA parameter. error channel
rameter axis assignment ter) must refer to a rotary
[%d]. system axis.
2542 Axes transformation: System axes numbers Adjust corresponding MA- Part program Reset of current
Configuration error in pa- must be different. CODA parameter. error channel
rameter axis assignment
[%d].
2543 permanent CPL variable For reading or writing a Correct the part program Part program Reset of current
doesn’t exist permanent CPL variable or define the permanent error channel
a nonexistent variable CPL variable in the con-
was programmed. cerning file.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–141

No Error text Cause Correction Error class Reset mode


2544 Wrong CPL expression An incorrect CPL expres- Modify part program. Part program Reset of current
sion was programmed for error channel
reading or writing a per-
manent CPL variable.
2545 Timeout while waiting for The CPL variable pro- Check the CPL variable Part program Reset of current
state of a permanent CPL grammed in wait com- and check the programs warning channel
variable. mand has not received for consistency.
the rated value in the
given time.
2546 The selected main The spindle defined by Please check the number Part program Reset of current
spindle (S%d) does not MACODA 702000010 of the main spindle in error channel
exist. does not exist. MACODA 702000010.
Notice: This parameter is
channel dependent.
2547 Spindle %d: More than Gear switching and Please split the line. Part program Reset of current
one spindle switch com- switching of SERCOS op- error channel
mand in this NC block. eration mode must not be
programmed in one NC
block.
2548 Spindle %d: SERCOS Thread cutting needs the Please modify the SER- Part program Reset of current
S-0-0051 or S-0-0053 is actual position of the COS configuration file for error channel
missing in S-0-0016(AT). spindle (C-axis). phase 2.
2549 Thread cutting, spindle For thread cutting the Please modify the SER- Part program Reset of current
%d: Unsuitable weighting weighting type for posi- COS configuration file for error channel
type for position data tion data (S-0-0076) must phase 2.
(S-0-0076). be set to rotary with mo-
dulo format.
2550 Thread cutting: Inclined During thread cutting no Modify the part program. Part program Reset of current
plane is activated. axis transformation is al- Deselect the inclined error channel
lowed. plane function while
thread cutting.
2551 Invalid axis programmed. Only main and second Please check the part Part program Reset of current
axis of the active plane program. error channel
can be used in combina-
tion with thread cutting.
2552 Retract angle is not al- Allowed angles are: 0 .. Please check and modify Part program Reset of current
lowed. 60 degrees and 90 de- the part program. error channel
grees.
2553 Thread lead (I, J, or K) is The lead for a longitudinal Please check the part Part program Reset of current
missing. thread is defined by the program. error channel
interpolation parameter of
the main axis of the ac-
tive plane. For a face
thread the lead is defined
by the parameter of the
second axis. E.g.: G18 ->
K = longitudinal thread I=
face thread.
2554 It is not allowed to pro- Only by using Use only the lead value of Part program Reset of current
gram the lead of the sec- CC220/Typ1-compatible the main cutting axis. error channel
ond cutting axis. programming mode a ta-
pered thread will be de-
fined by two lead values.
2555 Maximum lead (500 mm/ The allowed range for the Please check the part Part program Reset of current
rev) exceeded. thread lead (defined by I, program. error channel
J or K) is between 0.0001
and 500.

1070 073 799-102 (02.05) GB


3–142 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2556 Constant cutting velocity Thread cutting and G96 Please activate G97 in Part program Reset of current
(G96) is active. are incompatible. front of G33. error channel
2557 Illegal retract angle. The The retract angle must be Please check and modify Part program Reset of current
gradient and the retract greater as the gradient of the part program. error channel
angle are identical. the thread.
2558 Illegal retract angle. The programmed retract Please check and modify Part program Reset of current
angle will damage the the part program. error channel
part.
2559 Lead of the main cutting The allowed range for the Please check the part Part program Reset of current
axis must be greater than thread lead (defined by I, program. error channel
0.0001 mm/rev. J or K) is between 0.0001
and 500.
2560 The channel axis %s is Thread cutting allows Please check and modify Part program Reset of current
not a linear axis. only the usage of linear the part program. error channel
axes.
2561 Within a concatenated Please check and modify Part program Reset of current
thread it is not allowed to the part program. error channel
change the active plane.
2562 TPM %d: Inadmissible It is not allowed to Please check and modify Part program Reset of current
value while cutting a con- change the thread pro- the part program. error channel
catenated thread. gramming mode within a
concatenated thread .
2563 No distance for main cut- The main cutting axis, se- Please check the part Part program Reset of current
ting axis. lected by the interpolation program. error channel
parameter I, J or K,
needs to have a distance.
2564 The gradient of a tapered The gradient of a tapered Modify the part program. Part program Reset of current
thread exceeds 45 de- thread is limited by 45 de- Change from a longitudi- error channel
grees. grees. nal to a face thread or
vice versa.
2565 No valid retract data. Either there are no retrac- Check MACODA Part program Reset of current
tion data defined or they 705000645 or use G533 error channel
don’t match with the acti- RD( , ) to configure the
vated plane. retraction data.
2566 Resulting thread lead is At the end of a thread the Please check the part Part program Reset of current
less than 0. sum of constant (I, J or K) program. error channel
and variable thread lead
must be equal or greater
than 0.
2567 Chamfer cut and chamfer Function chamfer pro- Please adjust your part Part program Reset of current
length programmed to- gramming could be pro- program. error channel
gether in the same block. grammed either with
chamfer cut or with cham-
fer length.
2568 Function chamfer pro- Function chamfer pro- Please adjust your part Part program Reset of current
gramming has been acti- gramming could be pro- program. error channel
vated without specifying a grammed either with
chamfer. chamfer cut or with cham-
fer length.
2569 No chamfer could be cal- Due to geometry no Please adjust your part Part program Reset of current
culated. chamfer could be in- program. error channel
serted.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–143

No Error text Cause Correction Error class Reset mode


2570 Block via high speed While G575 is active, in- Please program G8, G9 Part program Reset of current
(G575) input does not terpolation and contour or G108. error channel
work together with active calculation have to be
path SHAPE function strongly coupled, which
(G408 or G608) means no post-interpola-
tion function may be ac-
tive.
2571 Error %d reading MA- Internal software error. No error recovery pos- Minor system System Restart
CODA parameter %d. sible! error
2572 Error during initialization The interpretation of the Correct the error and per- Minor system System Restart
of tool database: syntax file has been interrupted form a new initialization of error
error in file ”%s”, line %d. before the file end. The the tool database. You
indicated line contains a can do this, for example,
syntax error. by restarting the MMI.
2573 No digital output for No digital output is re- Reserve a digital output Part program Reset of current
punching available. served in MACODA. in MACODA. error channel
2574 No digital input for punch- No digital input is re- Reserve a digital input in Part program Reset of current
ing available. served in MACODA. MACODA. error channel
2575 Constant cutting velocity Spindle speed program- Part program Reset of current
is activated by a part pro- ming via machine func- error channel
gramme for spindle %d. tion is only permitted
when direct speed pro-
gramming (G97) is active.
2576 Constant cutting velocity Spindle speed program- Part program in the Info dia-
is activated by a part pro- ming via spindle jog is warning log with softkey
gramme for spindle %d. only permitted when di- ”Delete warn-
rect speed programming ings”
(G97) is active.
2577 No reference axis for MACODA 705000420 [6] Please modify the MA- Part program Reset of current
constant cutting velocity determines the reference CODA-parameter. error channel
(G96). axis.
2578 Axes of area %d are not A monitoring area shall Reference the axes first . Part program Reset of current
referenced be activated, whose ap- warning channel
propriate system axes are
not referenced.
2579 Tangential tool guidance: During tool guidance a Do not programme the Part program Reset of current
Tool axis was pro- motion for the tool axis tool axis or switch off tan- error channel
grammed. may not be programmed. gential tool guidance in a
previous NC block.
2580 Subprogram call (%s) in In default status of startup Modify MACODA param- Part program Reset of current
default status not allowed or control reset is a sub- eter of the default status. error channel
program call.
2581 No high-speed-output as- In MACODA 407500102 Please modify the MA- Part program Reset of current
signed to PDHSO. a high-speed-output must CODA-parameter. error channel
be assigned to PDHSO.
The range of values is
501 to 513.
2582 PDHSO: The pro- The allowed range for the Please check the part Part program Reset of current
grammed signal length signal length (3rd param- program. error channel
(%f msec) is out of range. eter) is between 0.5 and
10000.0 msec.
2583 PDHSO: The value of the Only 0 and 1 are allowed. Please check the part Part program Reset of current
1st parameter is not al- 0 allows to configure the program. error channel
lowed. function. 1 activates the
function.

1070 073 799-102 (02.05) GB


3–144 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2584 PDHSO: The 1st parame- The 1st parameter must Please check the part Part program Reset of current
ter is missing. be programmed. The program. error channel
value 0 allows to config-
ure the function. The
value 1 activates the
function.
2585 G532: Missing parame- Part program Reset of current
ters! warning channel
2586 homing of a coupled sys- A coupled axis may not De-couple Axis before Part program Reset of all
tem axis %s be homed. homing. error channels in
”DIAGNOS-
TICS” group op-
erating mode
2587 Inconsistency in Channel, Two coupled axes do not No correction required, Part program in the Info dia-
coupling deactivated belong anymore to the because coupling is al- warning log with softkey
same channel. ready opened. ”Delete warn-
ings”
2588 MACODA: The spindle The displayed syntax is Please check the MA- Part program System Restart
syntax %s is used multi- used multiple. Please CODA parameters. error
ple for spindle %d. check MACODA 1040
001xx.
2589 MACODA: The spindle The displayed syntax is Please check the MA- Part program System Restart
syntax %s is used multi- used multiple. Please CODA parameters. error
ple by spindle group %d. check MACODA 1040
002xx.
2590 MACODA: The spindle The displayed syntax is Please check the MA- Part program System Restart
syntax %s is used by used multiple. Please CODA parameters. error
spindle %d and %d. check MACODA 1040
001xx.
2591 MACODA: The spindle The displayed syntax is Please check the MA- Part program System Restart
syntax %s is used by used multiple. Please CODA parameters. error
spindle %d and spindle check MACODA 1040
group %d. 001xx and 1040 002xx.
2592 MACODA: The spindle The displayed syntax is Please check the MA- Part program System Restart
syntax %s is used by used multiple. Please CODA parameters. error
spindle group %d and check MACODA 1040
%d. 002xx.
2593 The chosen linear modulo The linear modulo axis Please check your part Part program Reset of current
axis is member of the ac- defined together with programme or switch of error channel
tual axis transformation. G105 has not to be mem- the actual axis trans-
ber of the actual axis formation.
transformation.
2594 An area was defined for Areas must not be de- Please check your part Part program Reset of current
an axis, which is member fined for axes, which are programme or switch of error channel
of the actual axis trans- member of the actual axis the actual axis trans-
formation. transformation. formation.
2595 Specified oscillation axis OscAxis must only be de- Please check your part Part program Reset of current
is member of the actual fined for axis, which are programme or switch of error channel
axis transformation. not member of the active the actual axis trans-
axis transformation. formation.
2596 The defined oscillation The oscillation axis func- Please check your part Part program Reset of current
axis is not channel mem- tions works only with programme. Please no- error channel
ber. axes of is own channel. tice that the physical in-
dex is needed for the def-
inition of the oscillation
axis.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–145

No Error text Cause Correction Error class Reset mode


2597 No linear motion type is The functions ’reference Please activate for exam- Part program Reset of current
active (e.g. G0, G1, point travel’ or ’travel to ple G0 or G1 before acti- error channel
G200). fix machine position’ need vating G0 or G1.
a linear motion as modal
motion generating func-
tion.
2598 The programming of While an axis transforma- Please adapt your part Part program Reset of current
WAIT function is missing. tion is active, WAIT has programme: Either pro- error channel
to be programmed in sep- gramme WAIT or switch
arate block before G74 or of axis transformation.
G76.
2599 Chosen tool axis is axis The tool axis for tangen- Please adapt your part Part program Reset of current
transformation member. tial tool control must not programme: check your error channel
be member of the actual tool axis or switch off the
axis transformation. axis transformation.
2600 The tool axis is member The tool axis of tangential Please check your part Part program Reset of current
of the actual axis trans- tool orientation function programme: verify your error channel
formation. must not be a member of tool axis or switch of ac-
the actual axis trans- tual axis transformation.
formation.
2601 Thread cutting axis is During thread cutting no Please adapt your part Part program Reset of current
member of actual axis axis transformation is al- programme: switch of the error channel
transformation. lowed. axis transformation.
2602 Physical axis pro- Datum point correction Please check part pro- Part program Reset of current
grammed together with refers to machine coordi- gramme and axis configu- error channel
DPC command is actual nates. Only for axis with ration.
axis transformation mem- identical axis and ma-
ber. chine coordinates, values
can be asked for.
2603 Tapping: c-axis is mem- During tapping, the c-axis Please check part pro- Part program Reset of current
ber of actual axis trans- must not be member of gramme and axis configu- error channel
formation. the actual axis trans- ration.
formation.
2604 No plain axis defined. The axis with the classifi- Please check your axes Part program Reset of current
cation 1 will become plain configuration including error channel
axis while activating di- the classifications (MA-
ameter programming. CODA parameter 7010
00030).
2605 Diameter axis is member For diameter axis only Please adapt your part Part program Reset of current
of actual axis transforma- such axis are permitted, programme: switch of the error channel
tion. which are no axis trans- axis transformation.
formation member.
2606 Drill axis switch G78: L3 Every correction direction Please check your part Part program Reset of current
(H) - tool correction of has to be assigned at programme , particular error channel
correction group 1 is as- maximum to one coordi- the programming of the
signed to more than one nate. G78 function. For more
coordinate. information see the DIN
programming instruction.
2607 Drill axis switch G78: L1 - Every correction direction Please check your part Part program Reset of current
tool correction of correc- has to be assigned at programme , particular error channel
tion group 2 is assigned maximum to one coordi- the programming of the
to more than one coordi- nate. G78 function. For more
nate. information see the DIN
programming instruction.

1070 073 799-102 (02.05) GB


3–146 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2608 Drill axis switch G78: L2 - Every correction direction Please check your part Part program Reset of current
tool correction of correc- has to be assigned at programme , particular error channel
tion group 2 is assigned maximum to one coordi- the programming of the
to more than one coordi- nate. G78 function. For more
nate. information see the DIN
programming instruction.
2609 Drill axis switch G78: L3 - Every correction direction Please check your part Part program Reset of current
tool correction of correc- has to be assigned at programme , particular error channel
tion group 2 is assigned maximum to one coordi- the programming of the
to more than one coordi- nate. G78 function. For more
nate. information see the DIN
programming instruction.
2610 Drill axis switch G78: in- Valid values are:(+)1, -1, Please check your part Part program Reset of current
valid correction direction (+)13, -13, (+)21, -21, programme , particular error channel
has been programmed. (+)22, -22, (+)23, -23 the programming of the
G78 function. For more
information see the DIN
programming instruction.
2611 NC block couldn’t be in- Internal software error. No error recovery pos- Part program Reset of current
serted. sible! error channel
2612 NC Function could not be The NC function NcfOr- No error recovery pos- Part program Reset of current
inserted. MoOff couldn’t be in- sible! error channel
serted.
2613 Invalid drive name Programmed drive name Modify part program. Part program Reset of current
starts neither with a num- error channel
ber nor a letter.
2614 Drive %s is not a spindle/ The programmed drive Modify part program. Part program Reset of current
C-axis name cannot determine a error channel
spindle/C-axis.
2615 Drive %d is not a spindle/ The programmed drive Modify part program. Part program Reset of current
C-axis number cannot determine error channel
a spindle/C-axis.
2616 Coordinates must not be In a block with an inclined Please program the new Part program Reset of current
programmed in the same plane, a datum point position in a separate fol- error channel
block with a transforma- transformation or an axis lowing block.
tion switch. transformation pro-
grammed, the program-
ming of a new position is
not allowed.
2617 No plane selected. Thread cutting is a plane Please check the part Part program Reset of current
dependent NC-function. program. error channel
Use G17 – G20 to select
a plane.
2618 Continuous error mes- Due to an internal soft- No error recovery pos- Minor system System Restart
sages from Task %s ware error the given task sible! error
continuously sets errors,
warnings, or messages.
Permanent errors, warn-
ings, or messages of this
task are ignored.
2619 Continuous warnings Due to an internal soft- No error recovery pos- Minor system System Restart
from Task %s ware error the given task sible! error
continuously sets errors,
warnings, or messages.
Permanent errors, warn-
ings, or messages of this
task are ignored.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–147

No Error text Cause Correction Error class Reset mode


2620 Continuous messages Due to an internal soft- No error recovery pos- Minor system System Restart
from Task %s ware error the given task sible! error
continuously sets errors,
warnings, or messages.
Permanent errors, warn-
ings, or messages of this
task are ignored.
2621 Programming of notes re- The programmed notes Correct the faulty part Part program System Restart
sults in continuous mes- or PRN statements in the program. warning
sages. part program result in
continuous messages.
2622 Error during initialization Internal software error. No error recovery pos- Minor system Reset of current
of subsystem WEA sible! error channel
2623 While path correction is Plane switch, inclined Switch transformations or Part program Reset of current
active transformations or plane, datum point trans- plane dimension in an error channel
active plane must not be formation, axis trans- own block after G40.
switched. formation or axis offset
must be switched while
the path correction func-
tion is not active.
2624 Spindle %d is actually The spindle is switched to Use G517( ) to switch Part program Reset of current
switched to c-axis mode. axis mode by G518( ). back to spindle mode. error channel
2625 SERCOS cycle time to T3 time is not in valid increase Baud rate or Servo loop or System Restart
small range of SERCOS cycle cycle time, use 2 rings drive fault
time
2626 Error Ncs_ErrReceiveFk- NCS callback function Searching in NCS call- Minor system System Restart
tAbort from %s. exit without return. back functions for missing error
return.
2627 At the moment axis %s At the moment this axis Release the axis by using Part program Reset of current
(spindle %s) cannot be (spindle) is reserved by a G512() or G513 from the error channel
switched to spindle mode. channel. channel and then switch
to spindle (G517).
2628 At the moment axis %s At the moment this axis Release the axis by using Part program Reset of current
(spindle %s) cannot be (spindle) is reserved by a G512() or G513 from the warning channel
switched to spindle mode. channel. channel and then switch
to spindle (G517).
2629 The AXO function must It’s No error recovery Please check and change Part program Reset of current
not be used for axes/ possible! to read prepara- your application. error channel
coordinates, which are no tion data of other chan-
member of the calling nels.
channel
2630 CPL function must not be There is no assignment Please check and change Part program Reset of current
called with physical axis between space coordi- your application. error channel
index when axis is not as- nates and a physical axis.
signed to a pseudo coor-
dinate.
2631 CPOS must not be called It’s No error recovery Please check and change Part program Reset of current
for axis/coordinates of possible! to read prepara- your application. error channel
other channels. tion data of other chan-
nels.
2632 CPROBE can’t evaluate CPROBE calculates Please enable the probe Part program Reset of current
any coordinates because coordinate probe values function for all channel error channel
probe function is locked with the latched axis axis in MACODA (Param-
for at least one axis. probe values. Therefor eter 1003 00012). Please
the probe values must ex- check the probe installa-
ist for all axis of the chan- tion of your drives.
nel.

1070 073 799-102 (02.05) GB


3–148 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2633 Invalid value. Only 0 and RON1 activates the fast Please check the part Part program Reset of current
1 are allowed. retraction data. RON0 de- program. error channel
activates the fast retrac-
tion.
2634 Program coordinate shift With program coordinate Please modify your part Part program Reset of current
is not allowed for orienta- shift function only linear program. error channel
tional coordinates. coordinates or pseudo
coordinates can be
shifted. In case of pseudo
coordinates all axis types
are allowed.
2635 Additional program coor- With additional program Please modify your part Part program Reset of current
dinate shift is not allowed coordinate shift function program. error channel
for orientational coordi- only linear coordinates or
nates. pseudo coordinates can
be shifted. In case of
pseudo coordinates all
axis types are allowed.
2636 Programmable contour With programmable con- Please modify your part Part program Reset of current
offset is not allowed for tour offset function only program. error channel
orientational coordinates. linear coordinates or
pseudo coordinates can
be shifted. In case of
pseudo coordinates all
axis types are allowed.
2637 Pole Definition for mirror- You can define a pole Please modify your part Part program Reset of current
ing, scaling or coordinate only for linear coordinates program. error channel
rotation is not allowed for or pseudo coordinates. In
orientational coordinates. case of pseudo coordi-
nates all axis types (in-
cluding rotational axis)
are allowed.
2638 The mirroring, scaling The mirroring, scaling Please modify your part Part program Reset of current
and coordinate rotation and coordinate rotation program. error channel
function is not allowed for function can only be ap-
orientational coordinates. plied on linear coordi-
nates or pseudo coordi-
nates. In case of pseudo
coordinates all axis types
(including rotational axis)
are allowed.
2639 Only positive signed Val- Within typ3 osa only posi- Please adapt your pro- Part program Reset of current
ues have to be pro- tive acceleration values gramming and write a error channel
grammed for path accel- do exist. positive acceleration
eration or path decelera- value.
tion.
2640 Programmed acceleration You can only can pro- Please adapt your pro- Part program Reset of current
value is larger than the gram an acceleration gramming and write a error channel
limit defined in MACODA value, that does not ex- valid acceleration value.
(parameter 7030 00210). ceed the limit defined in
MACODA.
2641 Programmed deceleration You can only can pro- Please adapt your pro- Part program Reset of current
value is larger than the gram an acceleration gramming and write a error channel
limit defined in MACODA value, that does not ex- valid acceleration value.
(parameter 7030 00220). ceed the limit defined in
MACODA.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–149

No Error text Cause Correction Error class Reset mode


2642 Database read error in The indicated MACODA Possibly the file system is Minor system System Restart
time check task. MA- parameter can not be defective. A system error
CODA parameter: %d read. startup with switch posi-
NcsErr: %d SqlErr: %d. tion ”6” creates a new file
system.
2643 NC function %s must be Order of NC functions in Program indicated NC Part program Reset of current
programmed in NC block the NC block is wrong. function first. error channel
before an axis.
2644 Axis %s (spindle %s): Drive controlled switching Bit 8 must not be set in Part program Reset of current
SERCOS secondary op- must not be activated in S-0-0034. error channel
eration mode 2 is wrong S-0-0034. Hint: S-0-0034 is local-
configured. ized in the SERCOS-file
for phase 2.
2645 Axis %s (spindle %s): S-0-0033 must be config- Please modify S-0-0033. Part program Reset of current
SERCOS secondary op- ured with position control. Hint: S-0-0033 is local- error channel
eration mode 1 is wrong ized in the SERCOS-file
configured. for phase 2.
2646 Axis %s (spindle %s): S-0-0034 must be config- Please modify S-0-0034. Part program Reset of current
SERCOS secondary op- ured with position control. Hint: S-0-0034 is local- error channel
eration mode 2 is wrong ized in the SERCOS-file
configured. for phase 2.
2647 Axis %s (spindle %s): MACODA ”rotary axis” Modify MACODA Part program Reset of current
The position data scaling can be combined with 100300004 or S-0-0076. error channel
method (S-0-0076) S-0-0076 ”rotary axis” or
doesn’t match with the ”endless axis”. MACODA
axis movement type (MA- ”endless axis” needs
CODA 100300004). S-0-0076 ”endless axis”.
2648 Axis %s (spindle %s): Un- For c-axis-mode only axis Please modify MACODA Part program Reset of current
suitable axis movement movement type ”rotary 100300004. error channel
type (MACODA axis” or ”endless axis”
100300004). can be selected.
2649 Drive %s: The position MACODA ”linear axis” Modify MACODA Part program in the Info dia-
data scaling method needs S-0-0076 ”linear 100300004 or S-0-0076. warning log with softkey
(S-0-0076) doesn’t match axis”. MACODA ”rotary ”Delete warn-
with the axis movement axis” can be combined ings”
type (MACODA with S-0-0076 ”rotary
100300004). axis” or ”endless axis”.
MACODA ”endless axis”
needs S-0-0076 ”endless
axis”.
2650 Wrong initialization of the Internal software error. No error recovery pos- Minor system System Restart
CPL server (Detailed sible! error
code : %d).
2651 Wrong initialization of the Internal software error. No error recovery pos- Minor system System Restart
CPL server (Detailed sible! error
code : %d).
2652 Invalid programming: pro- Contour error is an abso- Please change your MDI Part program Reset of current
grammed contour error lute value. respectively in the part error channel
must be greater than 0. program.
2653 Invalid programming: pro- Contour distance is an Please change your MDI Part program Reset of current
grammed corner distance absolute value. respectively in the part error channel
must be greater than 0. program.
2654 Axis %s (spindle %s) is The operation mode of Use G517( ) to switch Part program in the Info dia-
currently switched to C- the spindle drive and the back to spindle mode. warning log with softkey
axis-mode. This prevents NC must be equal while ”Delete warn-
switch off of general in- switching off general in- ings”
hibit. hibit.

1070 073 799-102 (02.05) GB


3–150 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2655 Axis %s (spindle %s) is The operation mode of Use G518( ) to switch to Part program in the Info dia-
currently switched to the spindle drive and the c-axis-mode. warning log with softkey
spindle-mode. This pre- NC must be equal while ”Delete warn-
vents switch off of gen- switching off general in- ings”
eral inhibit. hibit.
2656 Axis transformation: Sys- A member axis of an axis Change configuration Part program Reset of current
tem axis %s not in chan- transformation is no lon- data of the active axis error channel
nel. ger in the actual channel. transformation in MA-
CODA. If an axis channel
transfer has been pro-
grammed, switch off the
axis transformation be-
fore.
2657 Axis transformation: The axis transformation Change MACODA pa- Part program Reset of current
Wrong axis classification needs axis classification rameter for the axis clas- error channel
of the rotation axes. values from MACODA in sification.
order to determine the ac-
tual subconfiguration.
2658 Axis transformation: Sys- A member axis of an axis Change configuration Part program Reset of current
tem axis %s not in chan- transformation is no lon- data of the active axis error channel
nel. ger in the actual channel. transformation in MA-
CODA. If an axis channel
transfer has been pro-
grammed, switch off the
axis transformation be-
fore.
2659 Axes transformation: System axes numbers Adjust corresponding MA- Part program Reset of current
Configuration error in pa- must be different. CODA parameter. error channel
rameter axis assignment
[%d].
2660 Axes transformation: The first three axes must Adjust corresponding MA- Part program Reset of current
Configuration error in pa- be linear axes. CODA parameter. error channel
rameter axis assignment
[%d].
2661 Axes transformation: The last three axes must Adjust corresponding MA- Part program Reset of current
Configuration error in pa- be rotation axes. CODA parameter. error channel
rameter axis assignment
[%d].
2662 Axis transformation: The axis transformation Change MACODA pa- Part program Reset of current
Wrong axis classification needs axis classification rameter for the axis clas- error channel
of the rotation axes. values from MACODA in sification.
order to determine the ac-
tual subconfiguration.
2663 Error in the definition of The defined tool coordi- Adjust corresponding MA- Part program Reset of current
the tool coordinate sys- nate system is not right CODA parameter. error channel
tem. handed.
2664 NC Function could not be The NC function NcfOr- No error recovery pos- Part program Reset of current
inserted. MoOff couldn’t be in- sible! error channel
serted.
2665 NC block couldn’t be in- Internal software error. No error recovery pos- Part program Reset of current
serted. sible! error channel

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–151

No Error text Cause Correction Error class Reset mode


2666 Contour transition is dis- The programmed orienta- Insert a block without mo- Part program Reset of current
continuous for axis %s. tional motion cannot be tion after the WAIT block. error channel
performed continuously In mode MDI a short mo-
by the axes. The adaption tion out of the singularity
block for bridging the sin- must be programmed.
gularity (axis gap) was
not inserted. The reason
could be a WAIT in the
NC program or a motion
input in mode MDI.
2667 Wrong orientation pro- An O–programming with Modify part program. Part program Reset of current
gramming. two or three parameters error channel
is expected.
2668 Wrong TCS program- Exactly two TCS coordi- Modify part program. Part program Reset of current
ming. Only one TCS nates must be pro- error channel
coordinate is pro- grammed.
grammed.
2669 Tensor orientation: Syn- An O–programming with Modify part program. Part program Reset of current
tax with two parameters one or three parameters error channel
is unknown. is expected.
2670 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
tem CAN (detailed error sible! error
codes %d %d)
2671 Invalid CAN Identifier %d CAN Identifiers in Stan- Please correct identifier in Interface error System Restart
dard Format are limited to parameter 406000012 or
a range from 0 to 0x7F0 adapt format in parameter
(2032). 406000014.
2672 Path correction has been The path correction func- Please cancel the path Part program Reset of current
already activated! tion has been activated in correction function call in error channel
2 following NC-blocks. one of the 2 NC-blocks.
2673 While coordinate coupling While Coordinate cou- Please delete the coordi- Part program Reset of current
function is active no coor- pling function is active the nates addresses within error channel
dinate values should be coordinate positions will the coupling block.
programmed. be determined from the
master channel.
2674 While the coordinate cou- While coordinate coupling Please modify your part Part program Reset of current
pling function is active is active you should not program. error channel
you should not switch the switch inch/metric, plane,
coordinate base. coordinate transforma-
tion, axis transformation,
axis-zero-offset or axis
assignment.
2675 Invalid channel pro- For coordinate coupling Please program a valid Part program Reset of current
grammed for coordinate function a channel channel. error channel
coupling function. smaller than the actual
one must be pro-
grammed. Also channel 0
is invalid because of
missing axes/coordinates.
2676 No master channel has Please program a master More information is avail- Part program Reset of current
been programmed for channel with an index able in the programming error channel
coordinate coupling func- smaller than the coupling instruction.
tion. channel index.

1070 073 799-102 (02.05) GB


3–152 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2677 Coordinate coupling is Because of the initial Please program a linear Part program Reset of current
only allowed when a lin- movement of coordinate interpolation function to- error channel
ear interpolation function coupling function a linear gether with coordinate
is active, e.g. G0, G1, etc. interpolation function is coupling in the same
needed. block.
2678 1st parameter of REC- All valid system axis Please check and modify Part program Reset of current
PROBEx: There is no names are registered in the part program. error channel
system axis named %s. MACODA 100300001.
2679 1st parameter of REC- Please check and modify Part program Reset of current
PROBE%d: %d is not a the part program. error channel
valid system drive num-
ber.
2680 System axis %d (%s) is Via MACODA 105000002 Please check and modify Part program Reset of current
no member of a SERCOS this drive is disabled. the part program. error channel
loop.
2681 1st parameter of REC- For probes which does Please check and modify Part program Reset of current
PROBE%d: Invalid value. not refer to a drive you the part program. error channel
must use 0 as an axis
number.
2682 The 2nd parameter of Legal expressions are Please check and modify Part program Reset of current
RECPROBE%d (name) S-0-xxxx, P-0-xxxx, the part program. error channel
contains a illegal expres- @-xxx and I-xxx.
sion.
2683 The 2nd parameter of Please check and modify Part program Reset of current
RECPROBE%d (name) the part program. error channel
contains an illegal SER-
COS ident. number.
2684 %s is missing in the SER- Drive data which are con- Please check and modify Part program Reset of current
COS drive telegram. figured in S-0-0016 con- the part program. error channel
figured drive can be re-
corded.
2685 The permanent CPL-vari- Please check and modify Part program Reset of current
able %s does not exist. the part program. error channel
2686 Internal problem: No valid Integer values with 1, 2 or Please check and modify Part program Reset of current
vartype detected for %s. 4 bytes and floating point the part program. error channel
values with 4 bytes can
be recorded.
2687 The type of the variable A CPL-variable with the Please check and modify Part program Reset of current
%s is DOUBLE. type DOUBLE can not be the part program. error channel
recorded.
2688 %s does not exist. Information about valid in- Please check and modify Part program Reset of current
ternal probes can be the part program. error channel
taken from the DIN pro-
gramming manual.
2689 The 3rd parameter of The allowed range of fac- Please check and modify Part program Reset of current
RECPROBE%d (factor) tor is between 1.0e-10 the part program. error channel
contains a illegal value. and 1.0e10.
2690 The 4th parameter of Only format-operators for Please check and modify Part program Reset of current
RECPROBE%d (format- signed integer values the part program. error channel
operator) contains a ille- (%d, %9d, ...) and floating
gal expression. point values with (%e,
%E, ...) or without expo-
nent (%f, %9.3f, ...) are
allowed.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–153

No Error text Cause Correction Error class Reset mode


2691 The 5th parameter of The range is: -108..-101, Please check and modify Part program Reset of current
RECPROBE%d contains 101..108, -8..-1 and 1..8. the part program. error channel
a illegal value.
2692 Probe %d referenced by Please check and modify Part program Reset of current
the 5th parameter of the part program. error channel
RECPROBE%d does not
exist.
2693 No probe programmed. At least one probe must Please check and modify Part program Reset of current
be programmed. the part program. error channel
2694 TID protected memory is Not enough memory to Part program Reset of current
empty. initialize the scanning de- error channel
vice.
2695 Internal error within %s. No error recovery pos- Part program Reset of current
Error code %d. sible! error channel
2696 The recording file is write The file or the directory, Remove the write protec- Part program Reset of current
protected. determinate by REC- tion from the file or the di- error channel
FILE(”path/name” ), is rectory.
write protected.
2697 The recording file can not Select another path (e.g. Part program Reset of current
be created. Device full. /mnt/...) or release me- error channel
mory on the selected de-
vice.
2698 The parameter RECFILE The parameter REC- Please check and modify Part program Reset of current
is missing. FILE(”path/name”, , ) de- the part program. error channel
termines the recording
file.
2699 The 2nd parameter of 0 (append) or 1 (rewrite) Please check and modify Part program Reset of current
RECFILE (rewrite) con- are possible values. the part program. error channel
tains a illegal value.
2700 The 3rd parameter of 0 (no reaction), 1 (feed in- Please check and modify Part program Reset of current
RECFILE (file-I/O) con- hibit) or 2 (feed hold) are the part program. error channel
tains a illegal value. possible values.
2701 The 1st parameter of The allowed range of time Please check and modify Part program Reset of current
RECTIME (time in ms) is between 0.5 and the part program. error channel
contains a illegal value. 10000.
2702 The 2nd parameter of 0 (no reaction) and 1 (in- Please check and modify Part program Reset of current
RECTIME (autostop) con- hibit recording during axis the part program. error channel
tains a illegal value. stop) are possible values.
2703 The 3rd parameter of 0 (no reaction) and 1 Please check and modify Part program Reset of current
RECTIME (potentiome- (adapt recording clock by the part program. error channel
ter) contains an illegal feed potentiometer) are
value. possible values.
2704 The scanning device is The scanning device Please check and modify Part program Reset of current
not configured. must be configured by us- the part program. error channel
ing RecordSetProbe and
RecordSet.
2705 RECPROBE%d: For hid- Please check and modify Part program Reset of current
den probes the 5th pa- the part program. error channel
rameter must not be pro-
grammed.
2706 RECPROBE%d is al- Please check and modify Part program Reset of current
ready configured. the part program. error channel
2707 The scanning device is The scanning device is Please check and modify Part program Reset of current
already active. activated by this channel the part program. error channel
or another channel.

1070 073 799-102 (02.05) GB


3–154 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2708 Collinear start and end The programmed orienta- Modify part program. Part program Reset of current
orientation. tion vector is parallel or error channel
anti-parallel to the start
orientation vector. Hence
the rotation axis is unde-
fined.
2709 %s is a invalid separator. Only printable 7-bit ASCII Please check and modify Part program Reset of current
characters (hex 20 to Hex the part program. error channel
7E) are allowed.
2710 The Machine function Part program Reset of current
channel is not authorized error channel
to start the scanning de-
vice.
2711 The scanning device is Please check and modify Part program Reset of current
not active. the part program. error channel
2712 The scanning device is The scanning device is a Part program Reset of current
initialized or started by single user device. error channel
channel %d.
2713 Scanning device: Buffer Part program Reset of current
overrun. error channel
2714 Spindle %d: Gear range Part program Reset of current
switching is active. error channel
2715 Error during installation of Internal software error. No error recovery pos- Serious system System Restart
DCIO driver sible! error
2716 Not enough runtime me- Too small a value for Enlarge the data range Part program Reset of current
mory (stack) available. stack defined in MA- for stack in MACODA pa- error channel
%s bytes are needed. CODA block number rameter 707000010 and
707000010 ”Data areas initiate a new system
for CPL programs”. startup.
2717 Can’t create task %s. Er- It is No error recovery No error recovery pos- Serious system System Restart
to ror: %d . possible! to create the sible! error
2719 task. There is not enough Initiate a system startup
memory, or the task could with switch position S1 on
not be found in the task ”1”.
table.
2719 Can’t create task %s. Er- It is No error recovery No error recovery pos- Core system in the Info dia-
ror: %d . possible! to create the sible! warning log with softkey
task. There is not enough ”Delete warn-
memory, or the task could ings”
not be found in the task
table.
2720 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
tem DIO (Error Codes %d sible! error
%d).
2721 System error in subsys- Internal software error. No error recovery pos- Minor system System Restart
tem DIO (Error Codes %d sible! error
%d).
2722 While constant velocity The constant velocity in- Please check whether an Part program Reset of current
interpolation is active, no terpolation is designed for auxiliary function has error channel
functions must be active a smooth contour spawn. been programmed, or a
which will reduce velocity In case of a needed ve- function such like ”in posi-
at the block end to zero. locity reduction at block tion” is active. NC-blocks
end, the velocity will jump without a programmed
to zero at block end. motion also demand for
velocity reduction.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–155

No Error text Cause Correction Error class Reset mode


2723 While linear velocity inter- The linear velocity inter- Please check whether an Part program Reset of current
polation is active, no polation is designed for a auxiliary function has error channel
functions must be active smooth contour spawn. In been programmed, or a
which will reduce velocity case of a needed velocity function such like ”in posi-
at the block end to zero. reduction at block end, tion” is active. NC-blocks
the velocity will jump to without a programmed
zero. motion also demand for
velocity reduction.
2724 While sinus velocity inter- The sinus velocity inter- Please check whether an Part program Reset of current
polation is active, no polation is designed for a auxiliary function has error channel
functions must be active smooth contour spawn. In been programmed, or a
which will reduce velocity case of a needed velocity function such like ”in posi-
at block end to zero. reduction at block end, tion” is active. NC-blocks
the velocity will jump to without a programmed
zero. motion also demand for
velocity reduction.
2725 While squared sinus ve- The squared sinus veloc- Please check whether an Part program Reset of current
locity interpolation is ac- ity interpolation is de- auxiliary function has error channel
tive, no functions must be signed for a smooth con- been programmed, or a
active which will reduce tour spawn. In case of a function such like ”in posi-
velocity at the block end needed velocity reduction tion” is active. NC-blocks
to zero. at block end, the velocity without a programmed
will jump to zero. motion also demand for
velocity reduction.
2726 channel synchronisation: A channel is programmed Check your part program. Part program Reset of current
channel %d cannot be that either doesn’t exist or error channel
stopped. cannot be controlled by
the calling channel.
2727 channel synchronisation: While there are stop con- Check your part program. Part program Reset of current
no change in order of ditions for coordinates ac- error channel
coordinates allowed. tive, the order of the coor-
dinates may not be modi-
fied.
2728 channel synchronisation: The maximum number of No error recovery pos- Part program Reset of current
Insertion of the control control functions is sible! error channel
function failed. reached in this block.
2729 Ramp interpolation func- The ramp interpolation A part program, which Part program Reset of current
tions should only be functions needs always a contains a ramp function error channel
called then operation complete sequence of interpolation could only
mode is automatic. motion. be started, if the actual
operation mode is auto-
matic.
2730 channel synchronisation: An axis or a coordinate is Check your part program. Part program Reset of current
axis or coordinate %d programmed that is not error channel
not allowed. known in the calling chan-
nel.
2731 Error during initialization Internal software error. No error recovery pos- Minor system System Restart
of serial NCS link. sible! error
2732 Tapping retraction: Sys- The named axis has been Restore the original chan- Part program Reset of current
tem axis %s is not a released from this chan- nel axis configuration. error channel
channel member. nel.
2733 Automatic tapping retrac- Please switch off axes Part program Reset of current
tion: Channel axis %s is a transformation or use the error channel
member of an axes trans- manual retraction func-
formation. tion.
2734 Interface server task Internal software error. No error recovery pos- Serious system System Restart
could not be installed. sible! error

1070 073 799-102 (02.05) GB


3–156 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2735 channel synchronisation: While there exists a stop Check your part program. Part program Reset of current
pseudo coordinate out of condition for a pseudo error channel
channel. coordinate, the coordi-
nate may not be removed
out of the channel.
2736 TC(7,...): An invalid value Euler angle phi must be Please programm a valid Part program Reset of
has been programmed for member of the rightside value for euler angle phi. error current channel
euler angle phi. halfopen intervall [0,360].
2737 TC(8,...): An invalid value Euler angle theta must be Please programm a valid Part program Reset of
has been programmed for member of the closed in- value for euler angle error current channel
euler angle theta. tervall [0,180]. theta.
2738 TC(9,...): An invalid value Euler angle psi must be Please programm a valid Part program Reset of
has been programmed for member of the rightside value for euler angle psi. error current channel
euler angle psi. halfopen intervall [0,360].
2739 Invalid correction type for Internal realisation error. There’s no work around Part program Reset of
tool correction with active available. Please contact error current channel
axis transformation has control or machine
been set. manufacturer.
2740 Wrong orientation pro- An O-programming with Modify part program. Part program Reset of
gramming. one or three parameters error current channel
is expected.
2741 Wrong orientation pro- Programmed tensor col- Correct Part program Reset of
gramming. umn has zero length. programming error, error current channel

2742 Invalid rotation axis pro- Rotation axis has zero Correct Part program Reset of
gramming. length. programming error error current channel
2743 Orientation programming Orientational coordinates Correct Part program Reset of
with invalid combination (Euler angles) have been programming error error current channel
of variables. used together with alter-
native orientational vari-
ables.
2744 Orientation programming Tensor columns together Correct Part program Reset of
with invalid combination with Euler angles or rota- programming error error current channel
of variables. tion axis have been pro-
grammed.
2745 Rotation axis not pro- The orientation program- Correct Part program Reset of
grammed. ming with a rotation angle programming error error current channel
requires a programmed
rotation axis.
2746 Tensor orientation: Syn- An O-programming with Correct Part program Reset of
tax with two parameters one or three parameters programming error error current channel
is unknown. is expected.
2747 Wrong orientation pro- Missing rotation angle in Correct Part program Reset of
gramming. rotation axis program- programming error error current channel
ming.
2748 operand area exceeded For further information re- Modify and download the PLC error Restart of PLC
fer to the programmer’s PLC program. program
manual.
2749 Data modul to small For further information re- Modify and download the PLC error Restart of PLC
fer to the programmer’s PLC program. program
manual.
2750 LMB adress error For further information re- Modify and download the PLC error Restart of PLC
fer to the programmer’s PLC program. program
manual.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–157

No Error text Cause Correction Error class Reset mode


2751 PLC instruction not avail- For further information re- Modify and download the PLC error Restart of PLC
able in this firmware fer to the programmer’s PLC program. program
manual.
2752 Jump destination error for For further information re- Modify and download the PLC error Restart of PLC
indirect jump fer to the programmer’s PLC program. program
manual.
2753 Incorrect length specified For further information re- Modify and download the PLC error Restart of PLC
for FIFO command fer to the programmer’s PLC program. program
manual.
2754 unknown program error For further information re- Modify and download the PLC error Restart of PLC
fer to the programmer’s PLC program. program
manual.
2755 C module stack overflow For further information re- Modify and download the PLC error Restart of PLC
fer to the programmer’s PLC program. program
manual.
2756 Instantiation data block For further information re- Modify and download the PLC error Restart of PLC
has not been allocated. fer to the programmer’s PLC program. program
manual.
2757 Parameter error in stan- For further information re- Modify and download the PLC error Restart of PLC
dard functions (STD- fer to the programmer’s PLC program. program
FUN) manual.
2758 Target string too small For further information re- Modify and download the PLC error Restart of PLC
fer to the programmer’s PLC program. program
manual.
2759 Error in remanent oper- For further information re- Modify and download the PLC error Restart of PLC
ands fer to the programmer’s PLC program. program
manual.
2760 Saving of operands into For further information re- Modify and download the PLC error Restart of PLC
static RAM is not sup- fer to the programmer’s PLC program. program
ported by version of hard- manual.
ware.
2761 Error at calling peripherie PLC system error – Minor system System Restart
driver error
2762 Error at calling peripherie Initalization of peripherie Check the bus wires for a PLC error System Restart
driver driver failed. short circuit.
2763 Error at installing per- Initalization of peripherie Check the bus wires for a PLC error System Restart
ipherie driver driver failed. short circuit.
2764 No valid forcing list found The file fix.bin doesn’t ex- Reload the valif forcing PLC error Restart of PLC
ist at the root directory. list program
2765 Sicherung der DBs ins For further information re- – PLC error Restart of PLC
statische RAM nicht fer to the programmer’s program
möglich manual.
2766 No master parameter set The file of the master pa- ”Correct the DP master Interface error Restart of PLC
(MPS) loaded rameter set for PROFI- parameter file by means program
BUS-DP doesn’t exist in of ””WinDp”” and copy it
system path. to the directory Rootdirec-
tory or to the userFE-
PROM.”
2767 Bus faulty Fieldbus communication Check the bus wires for a Interface error System Restart
error. short circuit.

1070 073 799-102 (02.05) GB


3–158 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2768 Slave configuration faulty No data traffic to the DP- ”Correct the DP master Interface error Restart of PLC
Slave parameter file by means program
of ””WinDp”” and copy it
to the directory Rootdirec-
tory or to the userFE-
PROM.”
2769 Slave not reachable No data traffic to the DP- ”Correct the DP master Interface error Restart of PLC
Slave parameter file by means program
of ””WinDp”” and copy it
to the directory Rootdirec-
tory or to the userFE-
PROM.”
2770 Error on TCP/IP Error during startup of No error recovery PLC error System Restart
TCP/IP. Network commu- possible!
nication is impossible. For
a detailed error descrip-
tion the parameter refers
to the error number in the
wera database.
2771 Error on TCP/IP Error during startup of No error recovery PLC error System Restart
TCP/IP. Network commu- possible!
nication is impossible. For
a detailed error descrip-
tion the parameter refers
to the error number in the
wera database.
2772 intern modul error Software error. No error recovery PLC error System Restart
possible!
2773 Destination string to small The length of the destina- Modify and download the PLC error Restart of PLC
tion string is to small PLC program. program
2774 valid position in source The accesspoint in the Modify and download the PLC error Restart of PLC
string source string doesn’t ex- PLC program. program
ist
2775 String range error The string operation is Modify and download the PLC error Restart of PLC
out of range PLC program. program
2776 CPU time of PLC task ex- The CPU time of PLC Reduce the runtime of the Core system in the Info dia-
ceeds max CPU time. task exceeds the max. PLC program or increase warning log with softkey
CPU time defined at MA- the max CPU time at MA- ”Delete warn-
CODA parameter CODA parameter ings”
206000211. 206000211.
2777 Error during initialization Internal software error. No error recovery Serious system System Restart
to of subsystem PCL. possible! error
2793 (code lines %d %d).
2794 By modifying the start Internal software error. Please contact the re- Part program Reset of
point coordinates the sponsible service divi- error current channel
valid array size for chan- sion.
nel coordinates has been
exceeded.
2795 By modifying the end Internal software error. Please contact the re- Part program Reset of
point coordinates the sponsible service divi- error current channel
valid array size for chan- sion.
nel coordinates has been
exceeded.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–159

No Error text Cause Correction Error class Reset mode


2796 PLC program to big The locate memory is to Change the locate me- Minor system System Restart
small for the PLC pro- mory at the MACODA or error
gram (softsps.bin) reload the PLC program.
The old PLC program is
saved at softsps.err
2797 System error in subsys- Internal software error. No error recovery Serious system System Restart
to tem PCL (code lines %d possible! error
2800 %d).
2801 NC block couldn’t be Internal software error. No error recovery Part program Reset of
inserted. possible! error current channel
2802 Axes transformation: Two entries in axis as- Adjust corresponding Part program Reset of
Configuration error in pa- signment (MACODA pa- MACODA parameter. error current channel
rameter axis assignment rameter) refer to the
[%d]. same system axis.
2803 Axes transformation: The entry in axis assign- Adjust corresponding Part program Reset of
Configuration error in pa- ment (MACODA parame- MACODA parameter. error current channel
rameter axis assignment ter) must refer to a linear
[%d]. system axis.
2804 Axes transformation: The entry in axis assign- Adjust corresponding Part program Reset of
Configuration error in pa- ment (MACODA parame- MACODA parameter. error current channel
rameter axis assignment ter) must refer to a rotary
[%d]. system axis.
2805 Axes transformation: The entry in axis assign- Adjust corresponding Part program Reset of
Configuration error in pa- ment (MACODA parame- MACODA parameter. error current channel
rameter axis assignment ter) must refer to an axis
[%d]. with axis classification un-
equal to zero.
2806 Axes transformation: The entry in axis assign- Adjust corresponding Part program Reset of
Configuration error in pa- ment (MACODA parame- MACODA parameter. error current channel
rameter axis assignment ter) must refer to an axis
[%d]. with axis classification un-
equal to zero.
2807 NC block couldn’t be in- Internal software error. No error recovery Part program Reset of
serted. possible! error current channel
2808 Contour transition is dis- The contour through posi- Insert a block without mo- Part program Reset of
continuous for axis %s. tion (0,0) potentially re- tion after the WAIT block. error current channel
quires the insertion of an
adaptation block with a
pure rotation axis motion.
Probably due to a WAIT
the adaptation block
couldn’t be inserted.
2809 Axis transformation: A member axis of an axis Change configuration Part program Reset of
System axis %s not in transformation is no lon- data of the active axis error current channel
channel. ger in the actual channel. transformation in MA-
CODA. If an axis channel
transfer has been pro-
grammed, switch off the
axis transformation be-
fore.
2810 At the time spindle %s A position controlled Please modify your part- Part program Reset of
cannot be switched to spindle can’t be switched program. Insert SDOM error current channel
tool turret mode. to tool turret mode. Sx=0 in front of G518().
Please activate the speed
interface.

1070 073 799-102 (02.05) GB


3–160 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2811 Spindle %s: The perm This CPL-variable, auto- Please initiate a system Part program Reset of
CPL-variable %s does maticly generated during startup. error current channel
not exist. startup, is needed to
store the tool turret posi-
tion.
2812 Spindle %s (axis %s): A SERCOS-error occurs Please initiate a system Part program System Restart
Loading turret position while loading the turret startup. error
failed. position. Initiate a
system startup to leave
this error state.
2813 Spindle %s (axis %s): Se- A SERCOS-error occurs Please initiate a system Part program System Restart
lecting SERCOS-parame- while switching the pa- startup. error
ter set %d failed. rameter set. Initiate a
system startup to leave
this error state.
2814 SERCOS-servicechannel Servicechannel locked or No error recovery Servo loop or Reset of
error %s-axis, identnum- drive error occured possible! drive fault current channel
ber %s, error code 0x%x
2815 Wrong axis index for The programmed axis is Program the index of a Part program Reset of
function measuring fixed not configured. configured axis. error current channel
stop
2816 Programming of axis No axis programmed for Program the concerning Part program Reset of
missing for measuring measuring fixed stop axis with the syntax error current channel
fixed stop ”MfsAxis...”
2817 Programmed axis %s ”Axis is not released in Adapt MACODA-parame- Part program Reset of
disabled for fixed stop MACODA-parameter ”” ter error current channel
fixed stop allowed”””
2818 Fixed stop %s-axis out of abs(fixed stop position - Check fixed stop, if nec- Part program Reset of
monitoring window akt. Position) > monitor- essary enlarge monitoring error current channel
ing window window
2819 Axis is blocked because Axis is blocked at fixed Correct programming Part program Reset of
of fixed stop stop, programming not al- error error current channel
lowed
2820 Fixed stop %s-axis not Too short motion pro- Correct programming Part program Reset of
reached grammed error error current channel
2821 In position logic (G61,...) ”Cutting a concatenated Please activate G62 in Part program Reset of
is active. thread and ””in position front of G33. error current channel
logic”” are incompatible.”
2822 Invalid spindle name %s . The programmed spindle Correct programming Part program Reset of
name cannot determine a error error current channel
spindle.
2823 The selected spindle – – Part program Reset of
does not exist. error current channel
2824 The selected (MACODA) – – Part program Reset of
spindle does not exist. error current channel
2825 Axis distance control: – – Part program System Restart
MACODA 705000712 warning
does not determine a ex-
isting drive.
2826 Axis distance control: The – – Part program System Restart
drive, selected by MA- warning
CODA 705000712, is dis-
abled via MACODA
105000002.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–161

No Error text Cause Correction Error class Reset mode


2827 Axis distance control: Legal expressions are – Part program System Restart
MACODA 705000714 - S-0-xxx, P-0-xxx and warning
%s is a illegal expression. @xxx.
2828 Axis distance control: In- – No error recovery Part program System Restart
ternal error within %s. Er- possible! warning
ror code %d.
2829 %s is missing in the Drive datas which are Please check MACODA Part program System Restart
SERCOS drive telegram. configured in S-0-0016 705000714. warning
can be used.
2830 Internal problem: Integer values with 1, 2 or Please check MACODA Part program System Restart
No valid vartype detected 4 bytes and floatingpoint 705000714. warning
for %s. values with 4 bytes can
be recorded.
2831 The type of the variable A CPL-variable with the Please check MACODA Part program System Restart
%s ist DOUBLE. type DOUBLE can not be 705000714. warning
used as a data source.
2832 The permanent CPL-vari- – Please check MACODA Part program System Restart
able %s does not exist. 705000714. warning
2833 The 1st paramter of – Correct Part program Reset of
DCAXIS( ) is missing. programming error error current channel
2834 The 2nd paramter of – Correct Part program Reset of
DCAXIS( ) is missing. programming error error current channel
2835 For this channel axis – Please check MACODA Part program Reset of
distance contol is not 705000700. error current channel
applied.
2836 The %s-axis not a linear – – Part program Reset of
axis. error current channel
2837 Axis distance control: – No error recovery Part program Reset of
Internal error within %s. possible! error current channel
Error code: %d.
2838 The %s-axis (selected by The axis distance control Please check and modify Part program Reset of
DCAXIS) is not a channel function works only with a the part program. error current channel
member. axis of its own channel.
2839 Illegal value for com- -1 and 1 are possible val- Correct programming Part program Reset of
pensation direction ues. error error current channel
(DCAXIS).
2840 The %s-axis (selected by The axis distance control Please check MACODA Part program Reset of
MACODA) is not a chan- function works only with a 705000702. error current channel
nel member. axis of its own channel.
2841 The filter time (%f msec) The allowed range of the Correct programming Part program Reset of
is out of range. filter time is between 0 error error current channel
and 40 msec.
2842 The programmed value The allowed input range Correct programming Part program Reset of
for maximum velocity is is between 0.001 and error error current channel
out of range. 999999.999 mm/min
(39370.078 inch/min).
2843 The programmed value The allowed input range Correct programming Part program Reset of
for maximum accelrera- is between 0.001 and error error current channel
tion is out of range. 99.9999 m/sec2 (3.937
*1000inch/sec2).
2844 The programmed value The allowed input range Correct programming Part program Reset of
for collision detection is is between 0 (off) and error error current channel
out of range. 999.999 mm (39.37 inch).

1070 073 799-102 (02.05) GB


3–162 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2845 The programmed value The allowed input range Correct programming Part program Reset of
for hole detection is out of is between 0 (off) and error error current channel
range. 999.999 mm (39.37 inch).
2846 The axis distance control – – Part program Reset of
function is not configured. error current channel
2847 The axis distance control The axis distance control Correct Part program Reset of
function is already active. function is already acti- programming error error current channel
vated by DistCtrlOn.
2848 The axis distance control – Correct Part program Reset of
function is not active. programming error error current channel
2849 Only positive values are Only a positive block time Correct Part program Reset of
valid for block time. makes any sense. programming error error current channel
2850 TID protected memory Data of virtual NC require It is necessary to make Minor system System Restart
empty (when %d bytes internal memory. But more memory available error
requested). there is no more memory for the system for exam-
available. ple by decreasing the
number of channels (MA-
CODA block no.
904000001) or decreas-
ing the number of blocks
in the preparation (MA-
CODA block no.
7060000110) or decreas-
ing the memory area for
CPL programs (MACODA
block no. 707000010).
The available free me-
mory is indicated under
Diagnosis –> Control –>
Memory –> Memory 2.
2851 Collision warning from – – Part program in the Info dia-
function ”%s”. warning log with softkey
”Delete warn-
ings”
2852 Internal error in Device- Internal software error. No error recovery Minor system System Restart
Net driver (error codes possible! error
%d %d).
2853 Internal error in Device- Internal software error. No error recovery Minor system System Restart
Net driver (error codes possible! error
%d %d).
2854 %s-coordinate is not pro- Coordinate is not member Activate axis transforma- Part program Reset of
grammable in channel of the actual axis trans- tion. error current channel
%d formation or there is no
axis transformation ak-
tive.
2855 Channel axis %s is a – – Part program Reset of
member of an axes trans- error current channel
formation.
2856 SERCOS-servicechannel Servicechannel locked or No error recovery Servo loop or Reset of all
error %s-axis, identnum- drive error occured possible! drive fault channels in
ber %s, error code 0x%x ”DIAGNOS-
TICS” group
operating mode
2857 Fatal error PROFI- Error without control from The DP-master software Interface error System Restart
BUS-DP master. DP master. must be restarted. Initiate
a system startup.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–163

No Error text Cause Correction Error class Reset mode


2858 DP slave unavailable (DP No data traffic to the DP- Check of the PDP wiring Interface error System Restart
slave address %d). Slave and the Slave causing
foults.
2859 Error of PDP-Configura- An error at the configura- Correct the DP master Interface error System Restart
tion (Slave %d) tionfile occurred. parameter file by means
of ”WinDp” and download
the configuration.
2860 Devicenet-slave unavail- No data traffic to the Check of the Devicenet Interface error System Restart
able (slave address %d). Devicenet-Slave wiring and the Slave
causing foults.
2861 Error of DeviceNet-Con- The DeviceNet configura- Check and correct the Interface error System Restart
figuration tion is incorrect. DeviceNet-configuration
with RSNetWorx.
2862 Init string: Switching of Switch over from spindle Please remove the Part program System Restart
spindle/turret axis is not into a turret axis (and vice switching command for warning
allowed. versa) is a combination of spindle/turret axis from
a logical and a mechani- the init string.
cal process.
2863 One or more PROFIBUS At least one of the slaves Check if all slaves are Interface System Restart
DP slaves missing. (%s) configured in the file of connected to the bus and warning
the master parameter set if the correct master-data
doesn’t respond to the file is used.
master’s requests.
2864 Slave not reachable. A Slave with an invalid Check slaves at bus and Interface error System Restart
(slave adress %d) identnumber is con- correct the DP master pa-
nected. rameter file by means of
”WinDp” and download
the configuration.
2865 CPU time of PLC task ex- The CPU time of PLC Reduce the runtime of the Core system in the Info dia-
ceeds max CPU time. task exceeds the max. PLC program or increase warning log with softkey
CPU time defined at the max CPU time at ”Delete warn-
MACODA parameter MACODA parameter ings”
206000211. 206000211.
2866 Inadmissible mirror factor Only values +1 or -1 are Correct Part program Reset of
for orientation vector. allowed. programming error error current channel
2867 Wrong number of param- Exactly three mirror Correct Part program Reset of
eters. factors must be pro- programming error error current channel
grammed.
2868 Inadmissible incremental Absolute programming Correct Part program Reset of
programming of polar must be used for vector programming error error current channel
coordinates of vector ori- orientation.
entation.
2869 No DeviceNet configura- The configuration for De- Build a new DeviceNet Interface error Restart of PLC
tion file loaded viceNet doesn’t exist. configuration with RSNet- program
Worx.
2870 Error of DeviceNet-Con- The DeviceNet configura- Check and correct the Interface error System Restart
figuration (Slave %d) tion is incorrect. DeviceNet-configuration
with RSNetWorx.
2871 Unknown error at Device- At DeviceNet slave an No error recovery Interface error System Restart
Net slave %d (errorcode: unknown error occurred. possible!
%d).
2872 DeviceNet master has no Short circuit on bus. Check the bus wires for a Interface error System Restart
bus connection. short circuit.
2873 Unadmissible zero point MIT transformation Use the functions pro- Part program Reset of
offset for axis %s. doesn’t allow a zero point grammed contour shift or error current channel
offset for the linear axis. inclined plane.

1070 073 799-102 (02.05) GB


3–164 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2874 Couldn’t create a backup There is not enough me- Enlarge memory at root Core system in the Info dia-
file by changing the PLC mory space to store the filesystem (min %d byte) warning log with softkey
program PLC program. The PLC and restart system. ”Delete warn-
program has been ings”
changed without backup.
2875 Error by creating the PLC There is not enough me- Enlarge memory at root Serious system System Restart
program file mory space to store the filesystem (min %d byte) error
PLC program. The load- and restart system.
ing of the PLC has been
aborted.
2876 Laser power control: In- The programmed name Correct Part program Reset of
valid coordiante name cannot determine a coor- programming error error current channel
%s. dinate.
2877 Laser power control: The The allowed range for the Correct Part program Reset of
programmed power power value is between programming error error current channel
value is out of range. 0.0 and 100.0%.
2878 Laser power control: A – Correct Part program Reset of
negative value is not al- programming error error current channel
lowed.
2879 Laser power control: Select the coordinates ei- Correct Part program Reset of
Plane programming and ther by plane program- programming error error current channel
coordinate programming ming ( PL( ) ) or coordi-
at the same time. nate programming
(CD( ) ).
2880 Laser power control: Un- MCD selects the MA- Correct Part program Reset of
known syntax ”%s”. CODA values. APL se- programming error error current channel
lects the active plane.
ASP selects the active
space.
2881 Laser power control: Not – Select via MACODA Part program Reset of
applied (no analog output 407500104 a analog out- error current channel
assigned). put.
2882 Laser power control: This hardware don’t have – Part program Reset of
No analog output avail- analog outputs. error current channel
able.
2883 Laser power control: Neither plane or space Correct Part program Reset of
No selected coordinates. nor coordinates selected. programming error error current channel
2884 Laser power control: Internal software No error recovery Part program Reset of
Internal error: %s is al- error. possible! error current channel
ready used by another
function.
2885 Laser power control: ”You can use the function Correct Part program Reset of
Inclined plane activated. ””Inclined Plane”” only in programming error error current channel
combination with the
coordinate selection ””Ac-
tive Space (ASP)””.”
2886 Laser power control: Not While selecting coordi- Correct Part program Reset of
a valid coordinate selec- nates via LFP CD() an programming error error current channel
tion. axes transformation was
active. Now is another or
no transformation active.
2887 Laser power control: – – Part program Reset of
The actual axes trans- error current channel
formation is not sup-
ported.

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–165

No Error text Cause Correction Error class Reset mode


2888 Laser power control: The coordinates selected Correct Part program Reset of
The selected coordinates via LFPxx CD() are no programming error error current channel
no longer exists. longer members of this
channel.
2889 Laser power control: – Correct Part program Reset of
Lower feed limit exceeds programming error error current channel
upper feed limit.
2890 Laser power control: – Correct Part program Reset of
Lower power limit ex- programming error error current channel
ceeds upper power limit.
2891 Rotation No error recov- Both axes/coordinates of For example program Part program Reset of
ery possible!. the actual plane must corresponding coordi- error current channel
either be spline members nates with spline coeffi-
or non-spline members. cients.
2892 Spline startpoint of coor- Spline coefficient 0 has a Adjust coefficient in NC Part program Reset of
dinate %s doesn’t match wrong value. program or increase toler- error current channel
endpoint of previous ance value in MACODA.
block.
2893 Wrong spline parameter The spline parameter is Correct Part program Reset of
length. less equal zero. programming error error current channel
2894 Spline members do not Main, second and normal For example program Part program Reset of
consist with inclined coordinate must either be corresponding coordi- error current channel
plane. all spline members or nates with spline coeffi-
non-spline members. cients.
2895 No memory to create the No error recovery Part program Reset of
inverse pathlength func- possible! error current channel
tion.
2896 Entry in Bootparameter The entry in the bootpara- Change the entry in the Interface in the Info dia-
line %d code (%d:%d). meter is not correct. bootparameter. New start warning log with softkey
of the target. ”Delete warn-
ings”
2897 The maximum motion While the position weight- Please check the motion Part program Reset of
limit of %s-axis has been ing is10-4 mm the maxi- commands in your part error current channel
suceeded. mum commanded posi- program. Is the axis refer-
tion is 214,748 m. ences and what’s about
the software limits?
2898 The minimum motion limit While the position weight- Please check the motion Part program Reset of
of %s-axis has been ing is10-4 mm the mini- commands in your part error current channel
suceeded. mum commanded posi- program. Is the axis refer-
tion is -214,748 m. ences and what’s about
the software limits?
2899 Programmed Position is Linear modulo axis mo- Adjust your part program. Part program Reset of
larger than modulo axis. dulo value limits the pro- May be you can define a error current channel
grammable motion re- different axis zero point.
gion.
2900 Invalid value of MACODA The indicated MACODA Enter MACODA value Interface error System Restart
parameter %d. parameter has an invalid and keep the specified
value. The value range range.
defined in MACODA is
discarded.
2901 System error in subsys- Internal software No error recovery Minor system System Restart
tem DIO (Error Codes %d error. possible! error
%d).
2902 Analog I/O of DCIOs This DCIO card is a ver- Change hardware module Interface error System Restart
missing. sion without analog inputs DCIO against another
or outputs. hardware version.

1070 073 799-102 (02.05) GB


3–166 Messages, warnings, errors in the Info-window

No Error text Cause Correction Error class Reset mode


2903 Highspeed output of The DCIO has only 6 Change the element 7 Interface error System Restart
DCIOs missing. highspeed outputs. and 8 of MACODA pa-
rameter 407500102 to not
in use (value: 0).
2904 Conflicting addresses for The addresses defined Check MACODA parame- Interface error System Restart
I/Os. (address: %s%d) for inputs and outputs ter and fieldbus configu-
(MACODA group 4075) ration and correct the
overlap with the ad- conflicting addresses.
dresses for the fieldbus.
2905 NCS: Invalid message. Internal software error. No error recovery Serious system System Restart
possible! error
2906 NCS: Invalid message. Internal software error. No error recovery Serious system System Restart
possible! error
2907 No access to Dnet Timeout occurred with re- Please initiate a system Interface error System Restart
ceiving and transmitting startup.
DNet messages

1070 073 799-102 (02.05) GB


Messages, warnings, errors in the Info-window 3–167

Notes:

1070 073 799-102 (02.05) GB


3–168 Messages, warnings, errors in the Info-window

Notes:

1070 073 799-102 (02.05) GB


Annex A–1

A Annex

A.1 Abbreviations

Abbreviation Description
ESD Electro-Static Discharge
Abbreviation for all terms relating to elec-
tro-static discharge, e.g. ESD protection,
ESD hazards, etc.
Fx Function key with number x
GOM Group Operating Mode
HP Main Program (’Hauptprogramm’)
LSEC Lead Screw Error Compensation
MBF Machine operating panel
MDI Mode “Manual Data Input“
MMI (cf. OI) Man-Machine Interface
MP Machine parameter
MSD Machine-Status Display
(MZA)
MTB Machine-Tool Builder
NC, CNC Numeric control (Computerized NC)
OI (cf. MMI) Operator Interface
PE Protective Earth
PLC Programmable Logic Controller
SK Softkey
SP Subprogram

1070 073 799-102 (02.05) GB


A–2 Annex

A.2 Index

Numbers Q
7–segment display, 2–8 Qualified personnel, 1–2

C R
Cause, 3–1 Release, 1–8
Correction, 3–1 Reset mode, 3–1

D S
Display contents, configuring in Info–window, 2–5 Safety instructions, 1–4
Documentation, 1–7 Safety markings, 1–3
Softkey
E Display error details, 2–4
EMC Directive, 1–1 Display last infos, 2–3
EMERGENCY–STOP devices, 1–5 Error, 2–5
Error classes, 2–1, 3–1 Filter, 2–5
Error messages Filter channel, 2–6
7–segment display, 2–9 Logbook, 2–7
Information–window, 2–3 Message, 2–5
Logbook, 2–7 Set filter, 2–5
NC status bar, 2–2 Show details, 2–6
Error table, sorted according to numbers, 3–2 Warning, 2–5
Error text, 3–1 Spare parts, 1–6
ESD Standard operation, 1–1
Electrostatic discharge, 1–6
grounding, 1–6 T
workplace, 1–6 Test activities, 1–5
ESD–sensitive components, 1–6 Trademarks, 1–8
Ethernet, display, 2–8
Event display
Details of Info–window, 2–6
Details of last events, 2–4
Last events, 2–3
Listing in the Information–window, 2–3

F
Filter channel, 2–6
Floppy disk drive, 1–7

G
Grounding bracelet, 1–6

H
Hard disk drive, 1–7

I
Information–window, 2–3

L
Logbook, Display, 2–7
Low–Voltage Directive, 1–1

M
Modules sensitive to electrostatic discharge. See ESD–sen-
sitive components

N
NC status bar, 2–2

1070 073 799-102 (02.05) GB


A–1

Bosch Automation Technology

Australia Great Britain USA


Robert Bosch (Australia) Pty. Ltd. Robert Bosch Limited Robert Bosch Corporation
Head Office Automation Technology Division Automation Technology Division
Cnr. Centre - McNaughton Roads Meridian South Meridian Business Park Fluid Power Products
P.O. Box 66 GB-LE3 2WY Braunstone 7505 Durand Avenue
AUS-3168 Clayton, Victoria Leicestershire USA-Racine, Wisconsin 53406
Fax (03) 95 41 77 03 Fax (01 16) 28-9 28 78 Fax (414) 5 54-81 03

Canada Robert Bosch Corporation


Robert Bosch Corporation Automation Technology Division
Automation Technology Division Factory Automation Products
6811 Century Avenue 816 East Third Street
CAN-Mississauga, Ontario L5N 1R1 USA-Buchanan, MI 49107
Fax (905) 5 42-42 81 Fax (616) 6 95-53 63

Robert Bosch Corporation


Automation Technology Division
Industrial Electronic Products
40 Darling Drive
USA-Avon, CT 0 60 01-42 17
Fax (860) 4 09-70 80

We reserve the right to make technical alterations

Your concessionary

Robert Bosch GmbH


Geschäftsbereich
Automationstechnik
Antriebs- und Steuerungstechnik
Postfach 11 62
D-64701 Erbach
Fax +49 (0) 60 62 78-4 28
1070 073 799-102 (02.05) GB · HB NC · BRC/ESM11 · Printed in Germany