Doc. No.

WI/QA/14
Belmaks Metal India PVT LTD
Belmaks Eff. Date 28/11/17
WORK INSTRUCTIONS / कार्य निर्देश Rev. No./date 00
PROCESS GAUGE CALLIBRATION
DEPTT. QA/QC

PURPOSE: Calibration of Pin/Plug Gauges & Receving gauges.

SCOPE: This W.I. covers calibration of all type of Pin/Plug Gauges Range Upto 35 MM.

RESPONSIBILITY: Engineer (QA)

REFERANCE EQUIPMENT: For Plug Gauges-Micrometer MM-07 (0-25 mm ) & MM-08 (25 -50 mm)
For Receving Gauges -Master Sample

ENVIRONMENTAL CONDITIONS: 20 ± 2° C

1.FIRST WE HAVE TO CHECK GAUGE


VISUALLY(NO DAMAGE, DENT & .
2 TAKE THE MICROMETER
3. AFTER THAT WE HAVE TO CHECK
THE GO SIZE & NO GO SIZE AS PER
SCRATCH) (CALIBRATED) CHECK ITS ZERO GIVEN DIM. OF THE PIN GAUGE.
ERROR AND DAMAGES ETC.

5.FOUND NOT OK THEN WE WILL SEND IT TO TOOL 4.NOTE THE OBSERVATION IN CALIBRATION
ROOM FOR THE CORRECTION AND NOTE IT IN F/QA/06 HISTORY CARD F/QA/06

SAFETY INSTRUCTIONS / सुरक्षा निर्देश

NOTE : MARK BELOW APPLICABLE EQUIPMENT

Prepared By Approved By