Professional Documents
Culture Documents
Architectural Model
Architectural Model
300
LIFT MAC. ROOM
2400
2400
100 thick Brick Bat Coba 100 thick Brick Bat Coba 100 thick Brick Bat Coba
100 thick R.C.C Slab 100 thick R.C.C Slab 100 thick R.C.C Slab
900
900
175
175
100 TH. R.C. SLAB
FRESH AIR INLET
625
625
BED ROOM INLET 450 Ø MANHOLE COVER OVER FLOW PIPE
STORE BED ROOM
LIVING CUM DINING KITCHEN
T-147.5
2950
2950
1350
1350
T-250 G.L.
150
175
175
800
800
1000
1175
625
625
LIVING CUM DINING STORE BED ROOM BED ROOM
T-147.5 KITCHEN
2950
2950
1350
1350
T-250 100TH P.C.C OVER 75 THK.B.F.S.
175
175
800
800
250
625
625
LIVING CUM DINING STORE BED ROOM BED ROOM
T-147.5 KITCHEN
2025
1525
2950
2950
1350
1350
15000
15000
T-250
175
175
800
800
250
OFFICE TOIL. TOIL.
WAITING AREA 250 4500 250
WAITING AREA T-147.5 5000
2950
2950
2775
2775
T-250
DETAILS OF S.U.G.W.R.
CAPACITY - 6200 LTS.
LIFT TOIL. TOIL. SCALE - 1 : 50.
USG LIFT X RAY LAB CT SCAN
WAITING AREA
T-152.5
3050
3075
T-250
3200
3200
GL PL
150
125
50 thick I.P.S Floor 50 thick I.P.S Floor
100 thick P.C.C 100 thick P.C.C
SECTION AT - AA SECTION AT - BB
AREA CALCULATION
LAND AREA (As Per Deed) = 17.00 DEC.
LAND AREA (As Per Site) = 17.00 DEC.
GROUND FLOOR AREA = 365.63 SQ.M (COMMERCIAL)
FIRST FLOOR AREA = 431.96 SQ.M (COMMERCIAL)
300
ST
FORE TOTAL AREA = 797.59 SQ.M (COMMERCIAL)
HARI 700
NOTES & SPECIFICATION :-
300
UA DA [75'-0"]
300
BET H SECOND FLOOR AREA = 431.96 SQ.M (DOCTOR'S RESIDENTIAL)
22860 S. TA
NK
30000
3
300
300 THIRD FLOOR AREA = 431.96 SQ.M (LAB RESIDENTIAL)
600
1. ALL DIMENTION AREA IN MM. UNLESS OTHERWISE STATED. .W.R.
S.U.G
5419
N
300
TE BI
AL WAS FOURTH FLOOR AREA = 431.96 SQ.M (OTHER STAFF RESIDENTIAL)
300
MEDIC AGE
4044
2. DEPTH OF SEPTIC TANK WILL NOT EXCEED THE DEPTH OF FOUNDATION OF THE BUILDING. GARB
VAT S.P. 1800
R. W.
TOTAL AREA = 1295.88 SQ.M (RESIDENTIAL)
4072
H. PIT
300 100 Ø Air Vent Pipe
3. ALL EXTERNA WALLS AREA 200 mm. THK. CONSTRUCTED WITH CEMENT SAND MORTAR 1:6 TOTAL FLOOR AREA = (797.59+1295.88) = 2093.47 SQ.M.
4020
S 300 2400
3000 450mm Ø Man Hole Cover
& INTERNAL WALLS ARE 125/75THK WITH 1:4 CEMENT SAND MORTAR. 100mm thick R.C.C. Slab 450Ø M.H COVER 100 TH R.C.C SLAB
4. REINFORCEMENT CEMENT CONC. WORK WITH CEMENT SAND STONE CHIPS (1:2:4). C.I GAS PIPE 100 THK. R. C. C. SLAB 450 Ø M. H COVER
3117 INLET
5. GRADE OF CONCRETE = M-20 AND GRADE OF STEEL = Fe 500. GL GL
900
OUTLET G.L
400
300
6. PLASTERING WITH CEMENT SAND MORTER 1:4 FOR R.C.C. WORK & 1:6 FOR BRICK WORK.
350
G.L SCUM LEVEL
1600
7. PLAIN CEMENT CONC. WITH SAND CEMENT & JHAMA KHOA (1:3:6).
In Let SCUM BOARD
1225
950
1400
AJIMUDDIN MALLIK & OTHERS
32918 [108'-0"]
900
28346 [93'-0"]
150TH P.C.C OVER 75 THK.B.F.S.
250
125 1000 125
SECTION
125 125
1000
PROPOSED FIFTH STORIED COMMERCIAL CUM
X
1500
RESIDENTIAL BUILDING PLAN OF OWNER - MISS
ANKITA KUNDU AND MISS PRIYANKA KUNDU,
PLAN WITH SECTIONAL
250
ROAD NAME - 34 NATIONAL HIGHWAY, AT MOUZA
ELEVATION OF RAIN WATER - BETHUADHARI, J.L. NO - 49, R.S. & L.R. DAG NO -
2500 2500 1250
3236 3000
HARVESTING PIT PLAN 413, R.S. KHATIAN NO. - 423, L.R. KHATIAN NO. -
300
3500
1744 2400 7000
2000
2000
T
700
DETAILS OF SOAK PIT 4761, 4762, P.S. - NAKASHIPARA, UNDER
ORES 22555 [74'-0"]
ARI F DETAILS OF SEPTIC TANK ( USER - 100 NOS. ) SCALE - 1 : 50.
300
A H
300
UA D S. TA
NK 9144 [30'-0"] WIDE NAYAN JALI BILWAGRAM GRAM PANCHAYAT, DIST. - NADIA.
BETH [75'-0"
] SCALE - 1 : 50.
22860
300
300
300
P.W.D. ROAD N.H. - 12
300
AL WA
MEDIC
600
BAGE I DO HEREBY CERTIFY THAT PLAN, ELEVATION AND SECTION AND OTHER STRUCTURAL
300
GAR
4044
300
VAT S.P. 1800 DETAILS OF THE PROPOSE BUILDING ON MOUZA - BETHUADHARI, J.L. NO - 49, R.S. & L.R.
R. W. DAG NO - 413, R.S. KHATIAN NO. - 423, L.R. KHATIAN NO. - 4761, 4762, UNDER BILWAGRAM
H. PIT
SITE PLAN
4072
300 GRAM PANCHAYAT HAVE BEEN PREPARED IN CONFORMING WITH ALL RELEVANT
PROVISIONS UNDER THE WEST BENGAL MUNICIPAL (BUILDING) RULES, 2007, THIS ALSO
Scale - 1:200 DOOR-WINDOW SCHEDULE TO CERTIFY THAT RELEVANT `NO OBJECTION ` CERTIFICATES FROM THE RESPECTIVE
W1
4020
300 2400 AUTHORITIES SUCH AS, FIRE AND EMERGENCY SERVICE DEPARTMENT, AIRPORT
3000 AUTHORITY, POLLUTION CONTROL BOARD, TELECOMMUNICATION DEPARTMENT ETC
W1
MKD. SIZE
AS APPLICABLE IN THIS REGARD, AREA ALSO ENCLOSED WITH THE APPLICABLE FOR
A D 1200x2100 SEEKING APPROVAL OF THE PLAN TO CONSTRUCT OF BUILDING ON THE SAID HOLDING.
W1 D1 900x2000
39.50 SQ.FT.
2875x1275
3.67 SQ.M.
ROOM
1800x2875 MRI SCAN D3 1000x2100
5.18 SQ.M. 6475x6400 1500x1350
55.70 SQ.FT. W
AREA - 41.44 SQ.M. 900x1350 KALLOL KUMAR GHOSHAL
CT SCAN AREA - 446.06 SQ.FT. W1
PH.-9477913661
W1 5975x4375 W2 600x600
AREA - 26.14 SQ.M.
3200 W
SIGN. OF E.B.S.(CLASS - I) / L. B. S.
AREA - 281.38 SQ.FT.
DECLARATION OF STRUCTURAL ENGG.
7475
3925
W W W2 W1
D 100 Ø R.W.P. I HEREBY CERTIFY THAT THE FOUNDATION AND SUPERSTRUCTURE OF THE BUILDING
PROPOSED FOR CONSTRUCTION AT MOUZA - BETHUADHARI, J.L. NO - 49, R.S. & L.R. DAG
800
7075 3775
W SLOPE NO - 413, R.S. KHATIAN NO. - 423, L.R. KHATIAN NO. - 4761, 4762, UNDER BILWAGRAM
TOILET 100 Ø R.W.P.
BALCONY
3200x1500
A A 2200x1250 GRAM PANCHAYAT HAVE BEEN PERSONALLY INSPECTED AND DESIGNED BY ME WILL
MANIC CHANDRA BHADDRA
1100
D REGISTRATION W KITCHEN SLOPE MAKE SUCH FOUNDATION AND SUPER STRUCTURE SAFE IN ALL RESPECT INCLUDING
325
CONTROL ROOM W W
1500 5650 PE
3350x1800 3250x3075 100 Ø R.W.P. O THE CONSIDERATION OF BEARING CAPACITY AND SETTLEMENT OF SOIL AND OTHER
PE
4950x3350 SL
AREA - 65.34 SQ.FT.
AREA - 6.07 SQ.FT.
AREA - 6.07 SQ.FT. SL CONDITIONS IF ANY, CONFORMING TO ALL STIPULATION OF ALL RELEVANT IS CODE OF
SLO
AREA - 16.58 SQ.M. W
4575
O
2875 AREA - 65.34 SQ.FT. PE PRACTICE AND NATIONAL BUILDING CODE.
SLO
RECEPTION
SLOPE
3350x1800
PE
AREA - 25.12 SQ.M. W1 7590x12525
SL
AREA - 270.39 SQ.FT. AREA - 9.71 SQ.M. D1 W O
PE
AREA - 104.52 SQ.FT.
SLO
BED ROOM
COLLECTION ROOM
PE
5575x4375 BED ROOM
4950x1875 DOCTOR (GEN) D1 6025x3075 W
28346 [93'-0"]
12075
UP
W1
AREA - 101.72 SQ.FT. D1 D1
AREA - 11.20 SQ.M. PH.-9477913661
9025
3000
9025
A A D1
LIVING
SIGN. OF STRUCTURAL ENGG.
DOCTOR (GAY) WAITING AREA D1 TOILET W2
1350 WIDE EXIT CORRIDOR W1 4500x2100 EYE/ORTHO 4650x11625 2700x1250
AREA - 9.45 SQ.M. 7750
UP
5600x2475 W1
AREA - 101.72 SQ.FT. D1 AREA - 13.86 SQ.M.
100 Ø R.W.P.
PE
AREA - 149.19 SQ.FT. BED ROOM
W
SLO
DOCTOR (CHI) 7075x4525
SLO
100 Ø R.W.P.
TOILET
PE
D1 4500x2100 D1
O
D2 3650x1200 BED ROOM
PE
SL
SL
W2 W1
AREA - 9.45 SQ.M. W
O
EYE/ENT 6025x3900
PE
ECG/NEV/PFT AREA - 101.72 SQ.FT.
5600x2475 SLOPE KALLOL KUMAR GHOSHAL
4000x5100 1125 WIDE PASSAGE W1
PH.-8420996898
12025
LIFT
UP
UP
LOBBY
6700x12025 3000x1650
3000
3000
3000
3000
DN
AREA - 80.57 SQ.M. A D A A A D
AREA - 867.26 SQ.FT.
2700
2700
DN
LIFT W.C. 1350 WIDE CORRIDOR
1500x 1350x W2
UP
UP
1250 1250
D2 600
5125 1350 2250 1350
MEDICINE
D1 SLOPE
4000x3675 USG TOILET SIGN. OF OWNER.
100 Ø R.W.P.
AREA - 14.70 SQ.M. W2
4950x2450 W1 D2 3025x1125 SL
2675
AREA - 158.23 SQ.FT. AREA - 12.13 SQ.M. 1800 1800
STORE W1 O
PE
6700
SLO
AREA - 130.57 SQ.FT. LABORATORY D2 TOILET 3625x2400 OPEN TERRACE - V
4750
UP
W1 7125x4400 3025x1125 W2
PE
W 5500x4300 W1
3236 3000 AREA - 31.35 SQ.M.
W1 AREA - 337.45 SQ.FT. D3
600
3050x1800
3050x1800
D LIFT LIFT
1550
D1
LOBBY
LOBBY
3000x1650 3000x1650
1744 2400 D1 LIFT MACHINE ROOM
3500
3500
10525
2000
2000
5225x5725 D1
9144 [30'-0"] WIDE NAYAN JALI D1 BED ROOM APPROVAL AUTHORITY
AREA - 29.91 SQ.M. OFFICE 4000x5775 D2 D1
5775
W1
AREA - 321.95 SQ.FT. 3300x5500 PREPARED BY
D1 D2
2925x1500
SLOPE
OFFICE
PE
SLO
SOUMYADE MONDAL (CIVIL ENGINEER), BARUIPUR, Mo - 9064849423,
E
W1
TOILET
OP
4150x3950
SLO
2175x1375
KITCHEN
PE
PE
PE
TOILET
SL
OFFICE
SL
SPACE FOR OFFICE USE ONLY.
O
3925x2925 LO
O
SL
3650x2725
PE
S
P.W.D. ROAD N.H. - 12 SLOPE SLOPE
PRO. GROUND FLOOR PLAN PRO. FIRST FLOOR PLAN PRO. TYPICAL FLOOR PLAN ROOF PLAN