Report of Thorough Examination No. 550028-02

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 56

Report of Thorough Examination

This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 18. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-07ae6

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9900-P Pad Eye 0.25 AX-2014-1183 Polishing Filter 2 (Wellhead Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9900-P 44 Red Certificate missing 02. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 1 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 18. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-a7d7d

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9720-M Beam 2.00 AX-2014-1164 VFD Building Roof (Wellhead Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9720-M 60 Red Certificate missing 09. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 2 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 15. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-3de55

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9780-M Beam 4.00 AX-2014-1190 Water Injection Pump (Cellar Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9780-M 55 Red Certificate missing 09. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 3 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 15. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-9e8bd

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9770-M Beam 4.00 AX-2014-1191 Water Injection Pump (Cellar Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9770-M 54 Red Certificate missing 09. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 4 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 16. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-bf6f4

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9700-M Beam 5.00 AX-2014-1167 Booster Pump (Wellhead Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9700-M 62 Red Certificate missing 09. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 5 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 31. Dec. 2023 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 30. Dec. 2024 Report number: 202402281256-90db3

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9740-P Pad Eye 0.25 AX-2014-1189 Valve Access Platform (Wellhead Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9740-P 43 Red CERTIFICATE MISSING 31. Dec. 2023 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 6 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 16. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-b621f

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9790-M Beam 4.00 AX-2014-1212 Water Injection Pump (Cellar Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9790-M 56 Red Certificate missing 09. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 7 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 18. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-99519

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9900-M Beam 0.50 AX-2014-1165 Polishing Filter 2 (Wellhead Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9900-M 59 Red Certificate missing 09. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 8 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 15. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-27309

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9760-P Pad Eye 0.50 AX-2014-1222 Water Injection Pump (Cellar Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9760-P 46 Red Certificate missing 02. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 9 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-5bfd0

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9870-M Beam 2.00 AX-2014-1173 VFD Building Stair Porch (Cellar Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9870-M 52 Red Certificate missing 09. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 10 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 08. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-6af4c

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9740-M Beam 2.00 AX-2014-1166 Valve Access Platform (Wellhead Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9740-M 58 Red Certificate missing 09. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 11 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 16. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jul. 2024 Report number: 202402281256-5bc73

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9750 ZLG-5452-2 Trolley & Hoist Chester Hoist 2.00 AX-2014-723 Valve Access Platform (Cellar Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; 08. Oct. 2015
- particulars of any repair, renewal or alteration required to remedy it; See below
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
ZLG-5452-2 57 Red certificate missing 09. Jan. 2024 -
ZLG-5452-2 37 Amber Problems on moving sideways. Maintenance required. 16. Jul. 2015 08. Oct. 2015

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 12 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-5c6ad

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9840 Pad Eye 0.50 AX-2014-1179 Fire Water Pump 1 (Cellar Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9840 51 Red Certificate Missing 02. Jan. 2024 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 13 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 16. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 31. Dec. 2023 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 30. Dec. 2024 Report number: 202402281256-e9b53

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9710-P A Pad Eye 0.25 AX-2014-1187 Booster Pump (Wellhead Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9710-P A 42 Red Certificate missing 31. Dec. 2023 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 14 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 16. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 31. Dec. 2023 NOT safe to operate
The latest date by which the next thorough examination must be carried out: 30. Dec. 2024 Report number: 202402281256-80e4b

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9710-P B Pad Eye 0.25 AX-2014-1186 Booster Pump (Wellhead Deck) C Red
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
58-W-9710-P B 45 Red Certificate messing 31. Dec. 2023 -

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 15 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 08. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 16. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 15. Jan. 2016 Report number: 202402281256-b5b29

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley ZLG-5458-4M Trolley & Hoist Chester Hoist 4.00 AX-2014-1206 Water Injection Pump (Cellar Deck) C Amber
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* See below
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* See below
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; 08. Oct. 2015
- particulars of any repair, renewal or alteration required to remedy it; See below
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Serial# Finding# Status Defect Date Due date
ZLG-5458-4M 24 Amber Problems on moving sideways. Maintenance required. 16. Jul. 2015 08. Oct. 2015

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 16 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jul. 2024 Report number: 202402281256-9defc

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9870 AG-11539-2 Trolley & Hoist Chester Hoist 2.00 AX-2014-1158 VFD Building Stair Porch C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 17 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jul. 2024 Report number: 202402281256-cfe14

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9860 AG-11537-1.5 Trolley & Hoist Chester Hoist 1.50 AX-2014-1159 Sea Water Jockey Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 18 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 07. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 18. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 17. Jan. 2016 Report number: 202402281256-4bde1

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9890 AG-11541-5 Trolley & Hoist Chester Hoist 0.50 AX-2014-1152 Polishing Filter 1 (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 19 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 15. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 14. Jul. 2016 Report number: 202402281256-ce457

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9800-P Pad Eye 0.50 AX-2014-1217 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 20 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 16. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 15. Jul. 2016 Report number: 202402281256-6d93b

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9710-M Beam 2.00 AX-2014-1168 Booster Pump (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 21 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 15. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-29213

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9750-P Pad Eye 0.25 CTTE-1930-26-182 Valve Access Platform (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 22 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 18. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jul. 2024 Report number: 202402281256-433e8

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9900 AG-11543-5 Trolley & Hoist Chester Hoist 0.50 AX-2014-1154 Polishing Filter 2 (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 23 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-2e824

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye PA-58-W-9940-P Pad Eye 4.75 AX-2014-1177 Drill Water Pump 2 (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 24 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: - Date of report: 28. Feb. 2024 Date of Thorough Examination: 08. Nov. 2014 Safe to operate
The latest date by which the next thorough examination must be carried out: 07. May. 2015 Report number: 202402281256-0a6ff

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley ZLG-5459-4M Trolley & Hoist Chester Hoist 4.00 AX-2014-1207 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: gnascimento
To be defined
Client WO:

Page 25 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 08. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 17. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 16. Jan. 2016 Report number: 202402281256-97481

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9880 ZLG-5456-6 Trolley & Hoist Chester Hoist 6.00 AX-2014-1208 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 26 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-85e48

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9860-P Pad Eye 0.25 CTTE-1930-26-161 Sea Water Jockey Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 27 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 15. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-aae42

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9780-P Pad Eye 0.50 CTTE-1930-26-169 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 28 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 08. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 17. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 16. Jan. 2016 Report number: 202402281256-98ed8

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley ZLG-7214 Trolley & Hoist Chester Hoist 6.00 AX-2014-1210 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 29 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-13801

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9910 Pad Eye 3.25 CTTE-1930-26-167 Sea Water Lift Pump 1 (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 30 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 08. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 17. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 16. Jan. 2016 Report number: 202402281256-8f401

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley ZLG-7177 Trolley & Hoist Chester Hoist 4.00 AX-2014-1209 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 31 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-cfcd9

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9860-M Beam 1.50 CTTE-1930-26-183 Sea Water Jockey Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 32 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 17. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 16. Jul. 2016 Report number: 202402281256-e9f5f

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye PA-58-W-9920 Pad Eye 3.25 CTTE-1930-26-159 Sea Water Lift Pump 2 (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 33 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 08. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 17. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 16. Jan. 2016 Report number: 202402281256-2bc21

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9760 ZLG-5454-6 Trolley & Hoist Chester Hoist 6.00 AX-2014-1211 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 34 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-95e27

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9850-P Pad Eye 0.50 AX-2014-1180 Fire Water Pump 2 (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 35 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-2f66f

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9850-M Beam 5.00 CTTE-1930-26-186 Fire Water Pump 2 (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 36 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 15. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-efe98

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9770-P Pad Eye 0.50 AX-2014-1219 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 37 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 16. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 15. Jul. 2016 Report number: 202402281256-4b901

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9700-P Pad Eye 0.50 AX-2014-1188 Booster Pump (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 38 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jul. 2024 Report number: 202402281256-28650

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9700 ZLG 5446-5 Trolley & Hoist Chester Hoist 5.00 AX-2014-1156 Booster Pump (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 39 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 16. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 15. Jul. 2016 Report number: 202402281256-1497e

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9880-M Beam 6.00 AX-2014-1223 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 40 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 16. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 15. Jul. 2016 Report number: 202402281256-4f06b

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9800-M Beam 4.00 AX-2014-1214 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 41 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 17. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 16. Jul. 2016 Report number: 202402281256-0836f

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9870-P Pad Eye 0.25 AX-2014-1182 VFD Building Stair Porch (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 42 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 08. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jul. 2024 Report number: 202402281256-0dad6

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9850 AG-11536-5 Trolley & Hoist Chester Hoist 5.00 AX-2014-1160 Fire Water Pump 1 (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 43 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 15. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 14. Jul. 2016 Report number: 202402281256-7c31f

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9810-P Pad Eye 0.50 AX-2014-1216 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 44 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 16. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 15. Jul. 2016 Report number: 202402281256-ef2e7

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9810-M Beam 6.00 AX-2014-1213 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 45 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 15. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-9cc8e

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9790-P Pad Eye 0.50 AX-2014-1220 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 46 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 18. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jul. 2024 Report number: 202402281256-899bf

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9720 AG-11529-2 Trolley & Hoist Chester Hoist 2.00 AX-2014-1153 VFD Building Roof (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 47 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 18. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-40737

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9720-P Pad Eye 0.50 AX-2014-1185 VFD Building Roof (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 48 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-20f53

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9840-M Beam 5.00 AX-2014-1175 Fire Water Pump 1 (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 49 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 18. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-83514

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9890-P Pad Eye 0.25 CTTE-1930-26-101 Polishing Filter 1 (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 50 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 09. Nov. 2014 Date of report: 28. Feb. 2024 Date of Thorough Examination: 15. Jul. 2015 Safe to operate
The latest date by which the next thorough examination must be carried out: 14. Jul. 2016 Report number: 202402281256-2ffa1

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye 58-W-9880-P Pad Eye 0.50 AX-2014-1215 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: ldaquila
To be defined
Client WO:

Page 51 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jul. 2024 Report number: 202402281256-888e5

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9740 ZLG5450 Trolley & Hoist Chester Hoist 2.00 AX-2014-1155 Valve Access Platform (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 52 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jan. 2025 Report number: 202402281256-f79d4

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Attachment points
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Padeye PA-58-W-9930 Pad Eye 4.75 CTTE-1930-26-164 Drill Water Pump 1 (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 53 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 17. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 02. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 01. Jul. 2024 Report number: 202402281256-70158

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Lifting accessories and lifting components - Lifting accessories
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Trolley PA-58-W-9710 ZLG 5448-2 Trolley & Hoist Chester Hoist 2.00 AX-2014-1157 Booster Pump (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* NONE
Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Flavio Henrique Ramos Guerra
To be defined
Client WO:

Page 54 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 15. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-65faf

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9760-M Beam 6.00 AX-2014-1205 Water Injection Pump (Cellar Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* See below
Serial# Finding# Status Defect Date Due
date
58- 53 Green Approved at the behest of Equinor's Pedro Almeida, who requested that all monorails that have no trolley associated with them be 09. Jan. -
W-9760-M considered in their respective manufacturing certificates as "lifting foundations" in accordance with NORSOK R-200 without the need for 2024
a load test every 5 years.

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Augusto Maia
To be defined
Client WO:

Page 55 of 56
Report of Thorough Examination
This report complies with the requirements of the LOLER 1998 SI No 2307

Date of last thorough examination: 18. Jul. 2015 Date of report: 28. Feb. 2024 Date of Thorough Examination: 09. Jan. 2024 Safe to operate
The latest date by which the next thorough examination must be carried out: 08. Jan. 2025 Report number: 202402281256-f709e

The name and address of the employer for whom the thorough examination was made: The address of the premises at which the thorough examination was made:
Equinor ASA - Peregrino A
Groupname and Subgroup name: Foundations and suspensions - Runway beams
Item type Tag# Serial# Description Manufactured SWL/WLL Cert# Location * Status
Fixed beam 58-W-9890-M Beam 0.50 AX-2014-1163 Polishing Filter 1 (Wellhead Deck) C Green
*Was the examination As first examination after installation or Within an interval Within an interval In accordance with an After the occurrence of
carried out: assembly at a new site or location: A of 6 months: B of 12 months: C examination scheme: D exceptional circumstances: E

Is this the first examination after installation or assembly at a new site or location? No
If the answer to the above question is YES has the equipment been installed correctly? -
Identification of any part found to have a defect which is or could become a danger to persons, and a description of the defect; *If none stat NONE* None
Is the above an existing or imminent danger to persons *Note-This is a reportable defect No
Particulars of any repair, renewal or alteration required to remedy a defect found to be a danger to persons; *If none stat NONE* None
In the case of a defect which is not yet but could become a danger to persons
- the time by which it could become such danger; NA
- particulars of any repair, renewal or alteration required to remedy it; NA
Where the thorough examination included testing, particulars of any test; *if none stat NONE* See below
Serial# Finding# Status Defect Date Due
date
58- 61 Green Approved at the behest of Equinor's Pedro Almeida, who requested that all monorails that have no trolley associated with them be 09. Jan. -
W-9890-M considered in their respective manufacturing certificates as "lifting foundations" in accordance with NORSOK R-200 without the need for 2024
a load test every 5 years.

Project number: The name & Qualifications of person making this report: Name of person Authenticating this report on behalf of it’s author:
550028-02 Company Appointed Examiner
PO number: Augusto Maia
To be defined
Client WO:

Page 56 of 56