PG 2V SERIES

Telecomms Emergency UPS Solar Wind Utility


Lighting

PG-2V200
FEATURES
2V 212.0 AH @ 20-hr. • Absorbent Glass Mat (AGM) technology for
2V 200.0 AH @ 10-hr. superior performance

Rechargeable Sealed Lead Acid Battery • Wide capacity range ideal for large capacity
off-grid systems
PG 2V – High Capacity Long Life Series • Superb high-rate discharge characteristics ensures
reliable performance in UPS and telecom applications
TERMINALS: (mm)
• Proven valve regulated technology that guarantees
safe operation without maintenance
M8: Threaded insert with 20mm
8mm stud fastener M8 • Rugged impact resistant ABS case and cover
• Thick plate design and efficient gas recombination
6mm yield a design life of up to 16 years
• Excellent recovery from over discharge situations

APPROVALS
• Approved for transport by air. D.O.T., I.A.T.A., F.A.A.
and C.A.B. certified
• U.L recognized
Torque: 11.0~14.7 Nxm • ISO9001:2015 – Quality management systems

DIMENSIONS: inch (mm) PERFORMANCE SPECIFICATIONS


Nominal Voltage 2 volts
L: 6.69 (170) W: 4.33 (110)
H: 13.70 (348) HT: 13.26 (337)
W Tolerances are +/- 0.04 in. (+/- 1mm) and Nominal Capacity
+/- 0.08 in. (+/- 2mm) for height dimensions. 20-hr. (10.6A to 1.80 volts) 212.0 AH
All data subject to change without notice.
10-hr. (20.0A to 1.80 volts) 200.0 AH
5-hr. (35.0A to 1.75 volts) 175.0 AH
1-hr. (122.7A to 1.60 volts) 122.7 AH

Approximate Weight 29.8 lbs. (13.5 kg)

Internal Resistance (approx.) 0.9 milliohms

HT H Max Short-Duration Discharge Current (5 Sec.) 1600A

Shelf Life
PG 2V series batteries may be stored for up to 6 months at 25C (77F) and then a
freshening charge is required. For higher temperatures the time interval will be shorter.

Operating Temperature Range


L Charge -4°F (-20°C) to 104°F (40°C)
Discharge 5°F (-15°C) to 122°F (50°C)

GLOBAL HEADQUARTERS POWER-SONIC EMEA


(USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA – EUROPE, MIDDLE EAST AND AFRICA) Case ABS Plastic
Power-Sonic Corporation Smitspol 4, 3861 RS Nijkerk,
365 Cabela Dr Suite 300, The Netherlands
Reno, Nevada 89523 T NL: + 31 33 7410 700
USA T UK: + 44 1268 560 686
T: +1 775 824 6500 T FR: + 33 344 32 18 17
E: customer-service@power-sonic.com E: salesEMEA@power-sonic.com
Rev1: 12/21

To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.
© 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.
All data subject to change without notice. E&O.E www.power-sonic.com
PG 2V SERIES
PG-2V200 2V 212.0 AH @ 20-hr.
2V 200.0 AH @ 10-hr.

Rechargeable Sealed Lead Acid Battery


PG 2V – High Capacity Long Life Series
Effect
Effect
of Temperature
of Temperature
on Long
on Long
TermTerm
FloatFloat
Life Life Shelf
Shelf
Life Life
& Storage
& Storage
CYCLE LIFE IN RELATION TO DEPTH OF DISCHARGE GENERAL RELATION OF CAPACITY VS. STORAGE TIME
20 20 100 100

Capacity Retention Ratio (%)

Capacity Retention Ratio (%)


18 18 Charging isCharging
not is not
Life expectancy (Year)

Life expectancy (Year)

necessarynecessary
unless unless
16 16 100% of capacity
100% of capacity
12 12 is required.
is required.
10 10 Charging
Charging
voltage:voltage: 80 80
2.25V/cell
2.25V/cell
8 8 5°C 5°C Charging before
Charging before
use is necessary
use is necessary
(41°F) (41°F) to help recover
to help recover
5 5 full capacity.
full capacity.
60 60
Charge may fail may fail
Charge
2 2 to restore to
fullrestore full
40°C 40°C 30°C 30°C 20°C 20°C capacity. Do not Do not
capacity.
(104°F)(104°F)(86°F) (86°F) (68°F) (68°F) let batteries
let batteries
40 40 reach this reach
state.this state.
0.5 0.5
20 20 30 30 40 40 50 °C 50 °C 0 0
68 68 86 86 104 104 122°F 122°F 0 20 42 64 86 108 1210 1412 1614 1816 2018 20
Battery
Battery
Temperature
Temperature Standing
Standing
Period
Period
(months)
(months)

CHARGING CHARGERS
Cycle Applications: Apply constant voltage charge at Power Sonic offers a wide range of chargers suitable for
2.40V~2.50V at 25°C. Initial charging current should be batteries with a variety of capacities.
set at less than 60 Amps. Switch to float charge to avoid Please refer to our website for more information on our
overcharging. switch mode and transformer type chargers.
“Float” or “Stand-By” Service: Apply constant voltage Please contact our technical department for advice if you
charge of 2.23V~2.40V at 25°C. Initial charging current have difficulty in locating a suitable charger.
should be set at less than 60 Amps. When held at this
voltage, the battery will seek its own current level and
maintain itself in a fully charged condition. FURTHER INFORMATION
Temperature Compensation: Charging Voltage for both Please refer to our website www.power-sonic.com
Cyclic and Standby applications should be regulated in for a complete range of useful downloads, such as
relation to ambient temperature. As temperature rises product catalogs, material safety data sheets (MSDS),
charging voltage should be reduced to prevent overcharge ISO certification, etc.
and increased as temperature falls to avoid undercharge.
For further charging information including temperature
compensation factors, see Power Sonic Technical Manual/
Power Sonic Charger specifications.

APPLICATIONS
A whole range of CYCLIC applications including
but not limited to:
• Telecommunications • UPS • Wind
• Emergency Lighting • Solar • Utility
GLOBAL HEADQUARTERS POWER-SONIC EMEA
(USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA – EUROPE, MIDDLE EAST AND AFRICA)
Power-Sonic Corporation Smitspol 4, 3861 RS Nijkerk,
365 Cabela Dr Suite 300, The Netherlands
Reno, Nevada 89523 T NL: + 31 33 7410 700
USA T UK: + 44 1268 560 686
T: +1 775 824 6500 T FR: + 33 344 32 18 17
E: customer-service@power-sonic.com E: salesEMEA@power-sonic.com
Rev1: 12/21

To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.
© 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.
All data subject to change without notice. E&O.E www.power-sonic.com

You might also like