96M17512  Output circuit


Precautions on Regulations and Standards Specifications
Relay output Transistor (sink) output
 CE Marking  General Specifications
Keyence Corporation has confirmed that this product complies with the essential Isolated power supply
Item Specification
requirements of the applicable EU Directives, based on the following specifications. OUT

Internal circuit
AC power supply type Isolated protection power supply

KV Nano Series Be sure to consider the following specifications when using this product in the
KV-N14AR/AT/ATP
DC power supply type OUT

Internal circuit
Member States of European Union KV-N14DR/DT/DTP L
Power supply type KV-N24AR/AT/ATP
KV-N24DR/DT/DTP
 EMC Directive KV-N40AR/AT/ATP Protection circuit
Base Unit Instruction Manual • Applicable standard EMI: EN61131-2, Class A EMS: EN61131-2 KV-N60AR/AT/ATP
KV-N40DR/DT/DTP
COM
COM
• When installing the KV Nano Series, it must be installed in an conductive enclosure 100 to 240 VAC
Read this manual before using the product in order to achieve maximum performance. Supply voltage 24 VDC (+10% or -15%)
(+10% or -15%) (50/60Hz) Transistor (source) output
Keep this manual in a safe place after reading it so that it can be used at any time. (such as an industrial control panel) with IP54 or higher.
Output supply 24 VDC (±10%)
• Ground the enclosure (such as an industrial control panel) to FG (positive –
The user's manual that explains each function in detail is voltage (Output capacity: 0.6 A) COM

available for download from the following web site. grounding cannot be performed). KV-N14AR: 76 VA, KV-N14AT (P): 75 VA, KV-N14DR: 160 mA, KV-N14DT (P): 150 mA Isolated power supply
• If you are using the AC inlet of the KV Nano Series to connect the power supply, Internal current KV-N24AR: 79 VA, KV-N24AT (P): 76 VA, KV-N24DR: 190 mA, KV-N24DT (P): 160 mA Protection circuit

www.keyence.com/support_kv wrap the connecting cable once around a ferrite core*1. consumption KV-N40AR: 86 VA, KV-N40AT (P): 82 VA, KV-N40DR: 280 mA, KV-N40DT (P): 250 mA,

Internal circuit
• Ground the FG terminal of the KV Nano Series to the enclosure (such as an KV-N60AR: 91 VA, KV-N60AT (P): 85 VA (* VA is calculated with a power factor of 30%.) Output circuit

industrial control panel). Surrounding air


0 to 55°C (no freezing)*1, *2
temperature L
• Use a shielded cable for the signal lines located outside of the conductive
1500 VAC for 1 minute; between power supply terminal and I/O terminals, and
Introduction enclosure (such as an industrial control panel). The shielded cable must be Withstand voltage
between all external terminals and case
grounded. There is no change to the circuit diagram for general and high-speed output.
This manual describes how to operate the KV Nano Series. It also describes other 50 M or more (500 VDC megger used to perform measurements
However, do not ground the extension cassette's transmission cable, the base Insulation
between power supply terminal and I/O terminals, and between all
information such as operating procedures and precautions related to the KV Nano unit's internal serial cable, or the shielded USB cable. resistance
external terminals and case)  Power Supply Circuit Wiring Diagram
Series. • Pass the serial communication cable which connects to the base unit and the USB Operating atmosphere No excessive dust or corrosive gasses
To ensure proper use of the KV Nano Series, read this manual carefully and ensure that AC power supply type (KV-N**A*) DC power supply type (KV-N**D*)
cable through a ferrite core*1 twice. Altitude during
you fully understand the information contained within. 2,000 m or less
• When using an Ethernet unit (KV-NC1EP) at the same time as an expansion unit operation Terminals for the power Terminals for the
Take care to store this manual in a convenient location so that it is readily accessible for connection extension cable (OP-87581), pass both ends of the expansion unit Overvoltage AC: II FG C FG C0
supply circuit power supply circuit
reference whenever necessary. Please take care that the personnel who will actually connection extension cable (OP-87581) through a ferrite core*2 once. category DC: I AC_L AC_N 24V 0V

operate the product have access to this manual. *1 Ferrite core used by KEYENCE to perform evaluations: TDK ZCAT-3035-1330 Pollution degree 2 24V

0V

*2 Ferrite core used by KEYENCE to perform evaluations: TDK ZCAT-4625-3430D KV-N14AR: 430 g, KV-N14AT (P): 420 g, KV-N14DR: 350 g, KV-N14DT (P): 330 g
Safety Information for KV Nano Series Weight
KV-N24AR: 500 g, KV-N24AT (P): 470 g, KV-N24DR: 420 g, KV-N24DT (P): 390 g
KV-N40AR: 660 g, KV-N40AT (P): 620 g, KV-N40DR: 580 g, KV-N40DT (P): 530 g, FG
FG
For details, see the "KV Nano Series base unit (terminal block type) User's Manual." KV-N60AR: 820 g, KV-N60AT (P): 750 g, KV-N1: 90 g
 Symbols 24 V 0V
FG
*1 The range in which the system is guaranteed (excluding special cases). FG
The following symbols alert you to important messages. Be sure to read these AC_L AC_N
Remarks:
*2 Indicated on the lower, central part (30 mm) of the unit in the industrial control
messages carefully. These specifications do not give any guarantee that the end-product with this
panel. •

product incorporated complies with the essential requirements of EMC Directive. The C1 C1
Terminals for the • C1 C2

There is no service
Indicates a hazardous situation which, if not avoided, will result in death  Base unit Input Specifications 0V 500 5 • 500 50
DANGER manufacturer of the end-product is solely responsible for the compliance on the end- service power supply power supply.
or serious injury. KV-N14 **: R000 to R007 (8 points)
24V C1 C1 • C1 C2
product itself according to EMC Directive.
Indicates a hazardous situation which, if not avoided, could result in  Low-Voltage Directive KV-N24 **: R000 to R013 (14 points)
0V
WARNING
death or serious injury. The low-voltage directive applies to the following models: AC power supply type KV-N40 **: R000 to R107 (24 points) 24 V output
base units and relay output type base units and expansion units. The low-voltage KV-N60 **: R000 to R203 (36 points) (up to 0.6 A)
Indicates a hazardous situation which, if not avoided, could result in 24V
CAUTION directive does not apply to other models.
minor or moderate injury. Item 24 VDC Input (Open Collector)
• Applicable standard EN61010-1 Maximum input voltage 26.4 VDC
NOTICE
Indicates a situation which, if not avoided, could result in product
Rated input voltage 24 VDC (5.3 mA (6.5 mA)*1)  Base Unit Terminals Wiring Diagram
damage as well as property damage. EN61010-2-201
Minimum ON voltage 19 VDC
The contents within the rectangular frame are different for the AC power supply type
• Overvoltage category II
and DC power supply type.
Important Indicates cautions and limitations that must be followed during • Pollution degree 2 Maximum OFF current 1.5 mA
operation. • Be sure to install the KV Nano Series in an IP54 or better conductive enclosure Maximum OFF voltage –  KV-N14*R (14-point, relay output type)
(such as an industrial control panel). Common method All points/1 common (1 terminal)
Point Indicates additional information on proper operation. • The rated loads of the relays of the KV-N14AR, KV-N14DR, KV-N24AR, KV-N24DR, FG C0 001 003 005 007

*1 This is a reference value for the input current. The current varies depending on the AC_L AC_N 000 002 004 006
Type COM Terminal Relay Number
KV-N40AR, KV-N40DR, and KV-N60AR are 2 A per channel and 8 A per common. Input C0 R000 to R007
terminal.
Reference Indicates tips for better understanding or useful information. • Indoor use only.
• Install at an altitude of 2000 m or less.  Base unit Output Specifications Output C1 R500
• Use the DC power type models with one of the following power supplies. KV-N14 **: R500 to R505 (6 points) Output C2 R501
 Symbols on the product • UL/CSA certified power supply that provides Class 2 output as defined in the KV-N24 **: R500 to R509 (10 points) Output C3 R502
The symbol " " indicates Caution that is explained in this manual. NFPA70 (NEC: National Electrical Code) and CEC (Canadian Electrical Code). KV-N40 **: R500 to R515 (16 points) Output C4 R503 to R505
• UL/CSA certified power supply that has been evaluated as a Limited Power KV-N60 **: R500 to R607 (24 points) C1 C2 C3 C4

The symbol " " indicates functional earth terminal. 0V 500 501 502 503 505
Source as defined in UL60950-1 and CAN/CSA-C22.2 No. 60950-1. 24V C1 C2 C3 C4 504
Specification
 General precautions • Ensure the circuits to be connected to the input/output terminals are SELV circuits,
except for relay output type. Item Relay Output Type Transistor (sink/source)  KV-N14*T (P) (14-point, Transistor (sink/source) output type)
• Verify that this device is operating normally in terms of functionality and (KV-N***R) Output Type (KV-N***T (P))
performance before the start of work and when operating the device.  UL Certificate Output format Relay MOSFET output*1 FG C0 001 003 005 007
• Provide a safety circuit that does not pass via the programmable controller to The KV Nano Series is an UL/C-UL Listed Product. Type COM Terminal Relay Number
Rated load 250 VAC/30 VDC, 2 A 30 VDC, 0.5 A AC_L AC_N 000 002 004 006

enable failsafe operation of the entire system in the event that the programmable The UL mark is inscribed on the model indication label on the side of each unit that Input C0 R000 to R007
ON resistance 50 m or less –
controller fails. has received UL certification. Output C1 R500 to R505
Common method 2 to 4 points/1 common 8 to 10 points/1 common
• Output circuit or internal circuit malfunctions sometimes prevent control from being • UL File No. E207185 KV-N14AT

Overcurrent protection – Protected per common*2


performed normally. Be sure to provide a safety circuit in control systems where • Category NRAQ and NRAQ7
circuit malfunction may lead to fire or other serious accidents. Electrical: 100,000 times or
more (20 times/min)
• Proceed with care when modifying the device, or when using it in a manner that Be sure to consider the following specifications when using this product as an UL/ Relay life –
Mechanical: 20,000,000 times C1 C1 C1 C1

falls outside of the ranges indicated in its specifications, since KEYENCE is unable C-UL Listed product. or more 0V 500 501 502 503 505

to guarantee device functionality or performance in such situations. • When installing the KV Nano Series, it must be installed in an enclosure (Industrial Relay replacement Impossible – 24V C1 C1 C1 C1 504

• Use this device in combination with other devices only after careful consideration, control panel) with IP 54 or higher.
since the device may fail to satisfy its functionality and performance capabilities as • Supply power to the KV Nano Series using a UL Listing certified power supply that *1 Sink output types use MOSFET (N-ch) output. Source output types use MOSFET  KV-N24*R (24-point, relay output type)
a result of factors such as its usage conditions and the environment in which it is provides Class 2 output as defined in NFPA 70 (NEC: National Electrical Code). (P-ch) output.
used. • Use stranded copper wire having a wire gauge of AWG #14 to #20 and temperature *2 If an overcurrent occurs, until the cause of the problem is removed, the protection FG C0 001 003 005 007 009 011 013
Type COM Terminal Relay Number
24V 0V 000 002 004 006 008 010 012

• Do not use this product for the purpose to protect a human body or part of a human rating of 60°C or higher as the lead for wiring to the KV Nano Series power supply operation (output turning OFF) and automatic recovery occur repeatedly for all
24V 0V Input C0 R000 to R013
body. terminal block. Use a tightening torque of 0.59 to 0.88 N•m (5.2 to 7.8 lb.-In). outputs within the shared common.
Output C1 R500
• This product is not intended for use as an explosion-proof product. Do not use this • Use stranded copper wire having a wire gauge of AWG #14 to #20 and temperature  Base Unit I/O Circuit Diagrams KV-N24DR

Output C2 R501
product in a hazardous location and/or potentially explosive atmosphere. rating of 60°C or higher as the lead for wiring to the terminal blocks (use wires with  Input circuit
a temperature rating of 105°C or higher as the lead for wiring to the terminal blocks Output C3 R502
of relay type output units). Use a tightening torque of 0.59 to 0.88 N•m (5.2 to 7.8 General input High-speed A-phase or B-phase input Output C4 R503 to R505

lb.-In). • C1 C2 C3 C4 C5 C5

Output C5 R506 to R509


4.3k: Photocoupler isolation • 500 501 502 503 505 506 508 509

Internal circuit
Photocoupler isolation
• Maximum surrounding air temperature rating of 55°C. 004 to 007 3.3k: • C1 C2 C3 C4 504 C5 507 C5
IN

Internal circuit
• Use this product under pollution degree 2 environment. 510:
 KV-N24*T (P) (24-point, Transistor (sink/source) output type)
+
+ C0 560:

 KC mark (Republic of Korea) +


+
COM
FG C0 001 003 005 007 009 011 013
Type COM Terminal Relay Number
사용자안내문 24V 0V 000 002 004 006 008 010 012

General Input High-Speed Input 24V 0V Input C0 R000 to R013


이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 KV-N14** R000 to R003 R004 to R007
Output C1 R500 to R509
가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다 . KV-N24** R000 to R003 and R008 to R013 R004 to R007 KV-N24DT

KV-N40** R000 to R007 and R014 to R107 R008 to R013


KV-N60** R000 to R007 and R100 to R203 R008 to R015

• 500 501 502 503 505 506 508 509

• C1 C1 C1 C1 504 C1 507 C1

E1 E2
 KV-N40*R (40-point, relay output type) 4 Lock the lock levers attached on the top and bottom of the right unit.
Connecting Units WARRANTIES AND DISCLAIMERS
FG C0 001 003 005 007 009 011 013 015 101 103 105 107
COM Relay Be sure to observe the following points when connecting units. (1) KEYENCE warrants the Products to be free of defects in materials and workmanship
AC_L AC_N 000 002 004 006 008 010 012 014 100 102 104 106 Type
FG C0 Terminal Number for a period of one (1) year from the date of shipment. If any models or samples were
• Be sure to turn each unit and cassette off before you connect them.
Input C0 R000 to R107 shown to Buyer, such models or samples were used merely to illustrate the general
KV-N40AR
Output C1 R500 KV Nano Series Expansion unit type and quality of the Products and not to represent that the Products would
Base unit Up to eight units (three for KV-N14**) necessarily conform to said models or samples. Any Products found to be defective
Output C2 R501 must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to
Output C3 R502 to R503 KEYENCE for inspection and examination. Upon examination by KEYENCE,
C1 C2 C3 C4 C4 C5 C5 C6 C6

Output C4 R504 to R507


KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at
0V 500 501 502 504 505 507 508 509 511 512 513 515 • no charge any Products found to be defective. This warranty does not apply to any
24V C1 C2 C3 503 C4 506 C4 C5 510 C5 C6 514 C6 Output C5 R508 to R511 defects resulting from any action of Buyer, including but not limited to improper
Attaching Cassettes installation, improper interfacing, improper repair, unauthorized modification,
Output C6 R512 to R515
As an example, this section describes how to attach the KV-N1AW Expansion Access misapplication and mishandling, such as exposure to excessive current, heat,
 KV-N40*T (P) (40-point, Transistor (sink/source) output type) Window Cassette to the KV Nano Series Base unit. coldness, moisture, vibration or outdoors air. Components which wear are not
Point • You can use up to two expansion unit connection extension cables. warranted.
FG C0 001 003 005 007 009 011 013 015 101 103 105 107
COM Relay (However, do not connect the extension cables to each other.) Be sure to turn the units off before you begin connecting them. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are
AC_L AC_N 000 002 004 006 008 010 012 014 100 102 104 106 Type NOTICE
Terminal Number • If you connect two or more extension access window cassettes to a single only suggestions, and it is Buyer's responsibility to ascertain the fitness of the
Products for Buyer’s intended use. KEYENCE will not be responsible for any
Input C0 R000 to R107 base unit, the access window will not operate. 1 Remove the socket cover for the extension cassette on the base unit.
damages that may result from the use of the Products.
• Connector type units can be connected using connection conversion unit
KV-N40AT Output C1 R500 to R507
KV-N1.
2 Insert the extension cassette's connector into the extension cassette (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be
Output C2 R508 to R515 socket. used internally in humans, for human transportation, as safety devices or fail-safe
Maximum connectable units systems, unless their written specifications state otherwise. Should any Products/

You can connect up to eight expansion units (three for KV-N14**) per one base unit. Samples be used in such a manner or misused in any way, KEYENCE assumes no
responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE
0V 500 501 502 504 505 507 508 509 511 512 513 515 •
harmless from any liability or damage whatsoever arising out of any misuse of the
24V C1 C1 C1 503 C1 506 C1 C2 510 C2 C2 514 C2
Wiring Products/Samples.
 KV-N60AR (60-point, relay output type) (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED
 Unit Wiring Precautions WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND
FG C0 001 003 005 007 009 011 013 015 101 103 105 107 109 111 113 115 201 203
COM Relay  I/O unit wiring precautions STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE
AC_L AC_N 000 002 004 006 008 010 012 014 100 102 104 106 108 110 112 114 200 202
Type
C0
Terminal Number Note the following precautions when wiring I/O units. WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
Input C0 R000 to R203 • Wire the input and output cables separately. PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE
Reference
• When you insert the connector, ensure that it has a perpendicular EXPRESSLY DISCLAIMED.
KV-N60AR
Output C1 R500 • If I/O signal cables are close to power cables, the I/O signal cables may be orientation. Inserting the cassette into the socket at an angle may damage IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO
influenced by high voltage and current, which may lead to operation errors. I/O the products.
Output C2 R501 ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL,
signal cables should be laid at least 100 mm away from power cables. • If you are using the KV-N10L or KV-N11L, after you attach the cassette, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT
Output C3 R502 to R503 • Lay 24 VDC I/O cables separately with 100 VAC and 200 VAC power cables.
C7

tighten the fixation screw to hold the cassette in place before you use the LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS
0V 500 501 502 504 505 507 508 509 511 512 513 515 600 601 603 604 605 607 •
Output C4 R504 to R507 • When using cable conduits during wiring, ensure that the cable conduits are cassette. INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA,
24V C1 C2 C3 503 C4 506 C4 C5 510 C5 C6 514 C6 C7 602 C7 C8 606 C8

Output C5 R508 to R511 grounded securely. • When you want to use the base unit after removing the extension cassette, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
• Be sure to turn all equipment off before performing wiring. Failure to do so may lead you will require the extension cassette socket cover. Therefore, be sure to SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER
Output C6 R512 to R515 ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE
to electric shock and product damage. store the extension cassette socket cover in a safe place.
Output C7 R600 to R603 • After performing wiring or similar tasks, be sure to attach the terminal cover that is THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES
Output C8 R604 to R607 included with the product before turning the power on and performing operations. WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY
Failure to do so may lead to electric shock. Installing Units on DIN Rails OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing
 KV-N60AT (P) (60-point, Transistor (sink/source) output type) warranty disclaimers or damage limitations may not apply.
1 Hang the slot on the top of the DIN rail onto the DIN-rail fasteners on the
FG C0 001 003 005 007 009 011 013 015 101 103 105 107 109 111 113 115 201 203
COM Relay
Assembling Systems with Units top of each unit. BUYER'S TRANSFER OBLIGATIONS:
AC_L AC_N 000 002 004 006 008 010 012 014 100 102 104 106 108 110 112 114 200 202
Type If the Products/Samples purchased by Buyer are to be resold or delivered to a third party,
C0
Terminal Number As an example, this section describes how to assemble a system with the KV Nano 2 Insert the bottom part of the DIN rail into the DIN-rail fasteners on the Buyer must provide such third party with a copy of this document, all specifications, manuals,
Input C0 R000 to R203 Series base unit and the KV-N16EX Expansion I/O Unit. bottom of each unit. catalogs, leaflets and written information provided to Buyer pertaining to the Products/
KV-N60AT

Output C1 R500 to R507 3 Check that the bottom DIN-rail fasteners are all inserted (locked). Samples.
NOTICE Be sure to turn the units off before you begin connecting them.
Output C2 R508 to R515 E 1101-3

C1 C1 C1 C1 C1 C2 C2 C2 C2 C3 C3 C3 C3
• Output C3 R600 to R607  When connecting to a terminal block type expansion unit
1
0V 500 501 502 504 505 507 508 509 511 512 513 515 600 601 603 604 605 607 •

24V C1 C1 C1 503 C1 506 C1 C2 510 C2 C2 514 C2 C3 602 C3 C3 606 C3 Remove the expansion unit connection connector cover of the unit on
Top fastener
the left side. DIN rail
Installation Precautions 2 Connect the connector cable that is coming out of the left side of the
unit on the right to the expansion unit connection connector.
 Installation Environment 3 Attach the cover that you removed in step 1. Fastener is Fastener is
Do not install the device in the locations listed below. properly locked. not locked.
• Locations where series devices are exposed to direct sunlight.
• Locations where the surrounding air temperature range exceeds 0 to +55 °C. Installing Units Directly in an Industrial Control Panel
• Locations where relative humidity exceeds 5 to 95% RH.
• Locations subject to condensation due to rapid change in temperature.
Use the screw holes on the upper-left and lower-
• Locations where corrosive or flammable gasses are present.
right of each KV Nano Series unit to screw the
• Locations where there is excessive dust, salt, iron powder, or soot.
units directly into the panel surface.
• Locations where series devices are subject to direct vibrations or mechanical shocks.
• Locations where series devices are exposed to splashes of substances such as
water, oil, or chemical agents.
• Locations where strong magnetic or electrical fields are generated.  When Using the Expansion Unit Connection Extension Cable
• At altitude of 2,000 m at minimum. 1 Insert the female connector of the expansion unit connection extension cable
 Installation into the expansion unit connection connector of the unit on the left side.
Position 2 Pass the connector cable that is coming out of the left side of the unit on Removing the Terminal Block
When you install the KV the right through the top of the expansion unit connection extension
Nano Series Base Unit in a cable cover.
NOTICE Be sure to turn the power off before removing the terminal block.
panel, ensure that the
front panel and input
connectors face out.
1 Open the cover of the terminal block installed on the unit.
2 Remove the screws that are fixing the terminal block in place, and then
remove the terminal block.
 Surrounding 3 Pull the terminal block toward you to remove it.
• Pull the terminal block toward you with the minimum force required.
Space 30mm Above and to left of device
Allow a space of at least Allow 30 mm of space for
30 mm between the device 30mm heat dissipation. 3 Insert the connector cable of the unit on the right into the male connector.
and any walls or other
Series units
Below 4 Store the connected part in the expansion unit connection extension
equipment surrounding it. Allow 30 mm of space so that cable cover.
you can insert your finger
30mm to remove the lock lever.

Point If the panel temperature (the temperature at the bottom 30 mm of the


The screws are the ones that
unit) exceeds the ambient usage temperature, reduce the temperature by
fix the terminal block in place.
using methods such as forced air cooling and improving ventilation by
increasing the space around the device.
 When connecting to a connector type expansion unit
Point • You can remove the terminal block from the KV-N24**, KV-N40**, and KV-N60**.
1 Connect the left unit and the connection conversion unit KV-N1. • You cannot remove the terminal block from the KV-N14**. Copyright (c) 2023 KEYENCE CORPORATION. All rights reserved.
WARNING
During operation and shortly after power OFF, this equipment is heated 2 Release the lock levers attached on the top and bottom of the right unit. • You also cannot remove the terminal block from expansion I/O units 17512GB 2013-1 96M17512 Printed in Japan
up. Don’t touch it to avoid a burn. 3 Insert the right unit's lock lever into the lock lever slot on the left unit. and expansion special units.

E3 E4