Hitachi Combine Operation Boom Function Abnormal
Hitachi Combine Operation Boom Function Abnormal
Hitachi Combine Operation Boom Function Abnormal
Valid for
Case description
The machine of hydraulic function was slow. All attachment was slow. Machine Name plate
Delivery pressure abnormal. pump flow was abnormal.
Symptom
Reason
Hour Meter
firstly attachment function slow problem cause of torque control solenoid valve did not work.
Pump 1 & 2 delivery pressure wasn't normal condition cause of the delivery pressure sensor was damaged.
Combine operation boom function slow problem cause of boom flow rate control valve spool spring and arm2 flow rate
control valve spool spring was wrong assembly.
Action
firstly we checked torque control solenoid and max pump 2 flow rate control solenoid .And we found solenoid valve seal was
damaged .So we replactd new one .And we checked 3spools solenoid SC,SF,SI and SG. And then we tested run the machine
.Attachment function slow problem was OK. But boom function was still slow. So we checked boom anti-drift valve and arm
anti-drift valve .At the same time we checked boom flow rate control valve and arm 2 flow rate control valve .We found
wrong assembly boom spool spring and arm2 spool spring .So we installed normal condition .And we tested run the machine
.Boom function slow problem was OK. And combine function abnormal problem was OK.
Damage Parts Damage Parts Machine Photo
Suggestion
Firstly service team should be checked pump 1&2 delivery pressure ,control pressure.