TABLE OF CONTENTS REPUBLIC OF THE PHILIPPINES

MUNICIPALITY OF CABUYAO
1 TABLE OF CONTENTS PROVINCE OF LAGUNA
A1 4 PERSPECTIVE OFFICE OF THE BUILDING OFFICIAL
SITE DEVELOPMENT PLAN
01 09
VICINITY MAP
LAND USE & ZONING

FLOOR PLAN
2 ROOF PLAN
A2 4
ELEVATIONS

ARCHITECTURAL
PROJECT SITE
BARANGAY MAMATID, CABUYAO, LAGUNA
02 09 CROSS SECTION
LONGITUDINAL ELEVATION
REFLECTED CEILING PLAN
SCHEDULE OF CEILING FINISHES
3
A3 4 GROUND FLOOR FINISHED
LAYOUT
03 09 CEILING DETAILS LINE & GRADE
SCHEDULE OF DOORS AND
WINDOWS

4
A4 4 PERIMETER FENCE LAYOUT
PERIMETER FENCE DETAILS
04 09

1 ARCHITECTURAL
S1 3 STRUCTURAL NOTES

05 09
PERSPECTIVE VICINITY MAP
NOT DRAWN TO SCALE NOT DRAWN TO SCALE

S T R U C T U R A L
FOUNDATION PLAN
2 TIE BEAM FRAMING PLAN
S2 3 ROOF BEAM FRAMING PLAN
ROOF FRAMING PLAN
06 09
TYPICAL COLUMN-FOOTING
DETAILS STRUCTURAL
3389

3389

2706

3 FOUNDATION PLAN
S3 3 TIE BEAM FRAMING PLAN
ROOF BEAM FRAMING PLAN
67730
07 09
ROOF FRAMING PLAN
W

6288
ALO
D B UNG ING
E D
POS BUIL
PRO ENTIAL

PLUMBING ELECTRICAL
I D
RES LIGHTING LAYOUT
1 POWER LAYOUT

12576
E1 1 GENERAL NOTES PLUMBING

21840
LEGENDS/SYMBOLS
08 09
SINGLE LINE DIAGRAM

6288
SERVICE DROP INSTALLATION
11696

WATERLINE LAYOUT
1 SEWERLINE LAYOUT
P O
PAR
SED S
KIN G
P1 4 DRAINAGE LAYOUT
PRO SPACE GENERAL NOTES
09 09
LEGENDS/SYMBOLS
W AY TYPICAL PLUMBING DESIGN
RIVE
O S ED D ELECTRICAL
P
PRO 7.00m

2900

2910
249
40

58190
MECHANICAL
85

SITE DEVELOPMENT PLAN


72

SCALE 1:150 M
94
24

CIVIL ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.

PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE 1


CRIS EMANUELLE H. CASTOR
PERSPECTIVE A1 4
VICINITY MAP
PROJECT LOCATION SITE DEVELOPMENT PLAN
01 09
EVELYN L. ANTIOQUIA
PRC NO. : 0168420 12/07/26
PTR NO. : BTG 33336550 01/18/24 BARANGAY MAMATID, CABUYAO, LAGUNA ARCHITECTURAL
TIN NO. : 478-509-028-000 09/16/20
y 1 2 3 4 y'
y 1 2 3 4 4 3 2 1 y
12594
2425 3196 3395 2575 1000
APEX OF ROOF +5.63M APEX OF ROOF +5.63M

x'

1000

1000
F
KS KS TOP OF CEILING (OFFICE)+3.50M TOP OF CEILING (OFFICE)+3.50M
DIRTY MASTER'S
KITCHEN/ DINING TOP OF CEILING (HOUSE)+2.90M

2575
TOP OF CEILING (HOUSE)+2.90M
3076 ROOM ROOM
LAUNDRY
AREA KITCHEN
E

1350
T&B OFFICE/STORE FIN. FLR LINE+0.80M OFFICE/STORE FIN. FLR LINE+0.80M

T&B HOUSE FIN. FLR LINE+0.20M HOUSE FIN. FLR LINE+0.20M


C
CASHIER

LIVING ROAD FIN. FLR LINE+0.00M ROAD FIN. FLR LINE+0.00M


ROOM
11695

FRONT ELEVATION REAR ELEVATION


4216

2575
1:100 M
SHELVES SCALE SCALE 1:100 M

12822
BEDROOM

B C D E F F E D C B A
B
CASHIER
A 19 mm DROP
APEX OF ROOF +5.63M APEX OF ROOF +6.00M

PATIO CARPORT
3403

5322
TOP OF CEILING (OFFICE)+3.50M TOP OF CEILING (OFFICE)+3.50M
x
TOP OF CEILING (HOUSE)+2.90M TOP OF CEILING (HOUSE)+2.90M

5621 6973 F
F

12594 OFFICE/STORE FIN. FLR LINE+0.80M OFFICE/STORE FIN. FLR LINE+0.80M

HOUSE FIN. FLR LINE+0.20M HOUSE FIN. FLR LINE+0.20M


GROUND FLOOR PLAN ROAD FIN. FLR LINE+0.00M ROAD FIN. FLR LINE+0.00M
SCALE 1:100 M
RIGHT SIDE ELEVATION LEFT SIDE ELEVATION
SCALE 1:100 M SCALE 1:100 M

1 2 3 4

12594
6195 6895
y 1 2 3 4 A B C D E F
F
APEX OF ROOF +5.63M APEX OF ROOF +5.63M
GA#24, SS 304 GUTTER,
SATIN FINISH
SEE TRUSS DETAILS
GA#24, PRE-PAINTED
SEE TRUSS DETAILS
HI-RIB LONG SPAN, G.I ROOFING

E TOP OF ROOF BEAM+4.05M TOP OF ROOF BEAM+4.05M


SEE CEILING DETAILS
SEE CEILING DETAILS SEE CEILING DETAILS
TOP OF CEILING (OFFICE)+3.50M TOP OF CEILING (OFFICE)+3.50M SEE CEILING DETAILS
5%SLOPE

D SEE CEILING DETAILS SEE CEILING DETAILS


7500
5%SLOPE

TOP OF CEILING (HOUSE)+2.90M TOP OF CEILING (HOUSE)+2.90M


8292

OFFICE/STORE FIN. FLR LINE+0.80M OFFICE/STORE OFFICE/STORE FIN. FLR LINE+0.80M OFFICE/STORE

SLAB OB FILL SLAB ON FILL


HOUSE FIN. FLR LINE+0.20M CASHIER LIVING ROOM BEDROOM HOUSE FIN. FLR LINE+0.20M SLAB ON FILL KITCHEN

B ROAD FIN. FLR LINE+0.00M ROAD FIN. FLR LINE+0.00M

GA#24, PRE-PAINTED,
PLAIN G.I FLASHING
CROSS SECTION LONGITUDINAL ELEVATION
A SCALE 1:100 M SCALE 1:100 M

6195 6896
12594

ROOF PLAN
SCALE 1:100 M

CIVIL ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.

PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE FLOOR PLAN 2
CRIS EMANUELLE H. CASTOR
ROOF PLAN A2 4
ELEVATIONS 02 09
PROJECT LOCATION EVELYN L. ANTIOQUIA CROSS SECTION
PRC NO. : 0168420 12/07/26
PTR NO. : BTG 33336550 01/18/24 BARANGAY MAMATID, CABUYAO, LAGUNA LONGITUDINAL ELEVATION
ARCHITECTURAL
TIN NO. : 478-509-028-000 09/16/20
y 1 2 3 4 y' WALL ANGLE

ROD SUSPENSION HANGER


WITH ADJUSTMENT SPRING
SEE DETAIL "A" METAL DOUBLE FURRING CHANNEL
12mm. x 38mm. x 5m x 0.8mm. thk.
12594 DEPTH OF CEILING TO
REQUIRED DIMENSIONS
2425 3196 3395 2575 1000 SCHEDULE OF CEILING FINISHES:
PREFORMED
WIRE CLIP
MARKS DESIGN MATERIAL FINISH DESCRIPTION
x'

1000

1000
400mm THK. CEILING WITH GYPSUM BOARD PAINTED WITH FLAT LATEX PAINT
FLAT CEILING (THICKNESS VARIES ON BEAM HEIGHT)
CF - 1

F CF - 2
FLAT CEILING
(T & B)
400mm THK. CEILING WITH HARDIFLEX PAINTED WITH FLAT LATEX PAINT
(THICKNESS VARIES ON BEAM HEIGHT) METAL DOUBLE FURRING CHANNEL
12mm. x 38mm. x 5m x 0.8mm. thk.
DIRTY MASTER'S
KITCHEN/ KITCHEN DINING

2575
ROOM

3076
CF - 1
LAUNDRY ROOM CF - 1
CF - 1
AREA METAL CARRYING CHANNEL 12mm x 38mm x 5m x
CF - 1
E 0.8mm thk.
METAL CARRYING CHANNEL
12mm x 38mm x 5m x 0.8mm thk.
D CEILING DETAILS

1350
T&B
CF - 2
T&B 4.5mm thk. FIBER CEMENT BOARD (HARDIFLEX) SCALE NTS
CF - 1
C
CASHIER

LIVING
ROOM
11695

CF - 1 300 300 300


BEDROOM
4216

2575
50 50 50 50

12822
CF - 1
600 X 600 mm UNPOLISHED SYNTHETIC REINFORCED CONCRETE
GRANITE TILE FLOOR FINISH STAIR (ON-FILL)
OFFICE/STORE 300
CF - 1 600 X 600 mm UNPOLISHED SYNTHETIC
4
B PORCH FLOOR LEVEL GRANITE TILE FLOOR FINISH 50

200
PLAIN CEMENT FLOOR FINISH 6 mm THK. NON-SKID METAL NOSING STRIP
A (PROVIDE FLOOR HARDENER) (SUBMIT SAMPLE)

200
2

600

200
PATIO REINFORCED CONCRETE STAIR

200
1
CARPORT
3403

TOP OF SIDEWALK

5322

100
NATURAL GRADE LINE
SPOT DETAILS (PATIO)
x SCALE 1:16M

DETAIL OF STAIRS (PATIO)


SCALE 1:25M

5621 6973
12594 4000

±750 2500 ±750


GROUND FLOOR
200 2100 200 600
REFLECTED CEILING PLAN
SCALE 1:100 M

900 900
F

500
F F

200

200 200
JAMB
JAMB

2600

750

2200
F F

2100

2100

2100
JAMB

750
y 1 2 3 4 y'

300
JAMB

200
12594 300
2425 3196 3395 2575 1000 FINISH FLOOR LINE
R.C. POST W/ ALUMINUM METAL DW-1 D-1 D-2 D-3
SCHEDULE OF FLOOR FINISHES CLADDING (COLOR: ROYAL BLUE)
x' 600 X 600 mm UNPOLISHED SYNTHETIC GRANITE TILE FLOOR FINISH SEE MANUFACTURER'S SPECS 6.35mm. THK. TEMPERED CLEAR GLASS w/ ETCHED 45mm. THK. PANEL DOOR SINGLE LEAF BEDROOM DOOR
FL-1 PVC SWING DOOR W/
1000

1000

(SUBMIT SAMPLE FOR APPROVAL)

600 X 600 mm TEXTURED CERAMIC TILE (NON-SKID) FLOOR FINISH


STICKER ON TUBULAR ALUMINUM POWDER SWING TYPE ON 2"x5" HOLLOW CORE PANEL FIXED LOUVERS BELOW &
FL-2
F (SUBMIT SAMPLE FOR APPROVAL) COATED FRAME (WHITE) DOUBLE SWING DOOR WOODEN JAMB / MDF BOARD COMPLETE ACCESSORIES
FL-3 200MM X 900MM CERAMIC FLOOR TILES WOOD GRAIN DESIGN WITH FIXED TINTED GLASS PANELS ON BOTH SIDE FRAME
DIRTY & WITH FIXED ORDINARY GLASS TRANSOM ABOVE
MASTER'S 4 SETS 3 - SETS
KITCHEN/ KITCHEN DINING 200 X 200 mm VITRIFIED UNGLAZED TILES FLOOR FINISH (SIZE AND/OR COLOR
2575

ROOM FL-4 FOR APPROVAL BY END-USER) PROVIDE WATER BASE WATERPROOFING 1 - SET
FL - 1
3076

LAUNDRY ROOM FL - 3
AREA FL - 1 1 - SET
FL - 2
E

D
1350

T&B
FL - 4
T&B
FL - 4
C
CASHIER

LIVING
ROOM (DIVIDE INTO 2 EQUAL PARTS)
11695

FL - 1
2700 1200 600
BEDROOM
4216

2575

12822

FL - 3

600
OFFICE/STORE
FL - 1

800
F

1050
B

1100
F

1200
1350
A

200

2200
2150

200

1600
PATIO
FL - 2

1100
CARPORT

900
800
3403

RC COUNTER TOP w/
5322

GRANULITIC SLAB CLADDING

x W-1 W-2 W-3 FINISH FLOOR LINE


6.35mm. THK. TEMPERED CLEAR GLASS ON TUBULAR SLIDING TYPE 6.35mm. THK. TEMPERED CLEAR
ALUMINUM POWDER COATED FRAME (WHITE) FIXED ALUMINUM POWDER COATED WHITE COLOR GLASS ON TUBULAR ALUMINUM
WINDOW WITH SLIDING TEMPERED GLASS BELOW 10mm THICK CLEAR GLASS POWDER COATED FRAME
5621 6973
(WHITE) AWNING
12594 1 - SET QTY 6 SETS
4 - SETS

GROUND FLOOR FINISH LAYOUT SCHEDULE OF DOORS AND WINDOWS


SCALE 1:100 M SCALE 1:50M

CIVIL ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.

PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE REFLECTED CEILING PLAN 3
SCHEDULE OF CEILING FINISHES A3 4
CRIS EMANUELLE H. CASTOR
PROJECT LOCATION
GROUND FLOOR FINISHED LAYOUT 03 09
EVELYN L. ANTIOQUIA CEILING DETAILS
PRC NO. : 0168420 12/07/26
PTR NO. : BTG 33336550 01/18/24 BARANGAY MAMATID, CABUYAO, LAGUNA SCHEDULE OF DOORS AND WINDOWS ARCHITECTURAL
TIN NO. : 478-509-028-000 09/16/20
3389

3389

2706

67730
OW

6288
UN GAL G
ED B DIN
R O POS IAL BUIL
P T
DEN
RESI

12576

21840
6288
11696

G
RKIN
S E D PA
PO
PRO SPACES

W AY
D DRIVE
E
POS 00m
PRO 7.

2900

2910
249
40

58190
857

SITE DEVELOPMENT PLAN


2

SCALE 1:150 M

50X50mm STEEL TUBULAR GRILLS 50X50mm STEEL TUBULAR SLIDING GATE 50X50mm STEEL TUBULAR GRILLS
W/ PAINTED FINISH (COLOR: BLACK) W/ PAINTED FINISH (COLOR: BLACK) W/ PAINTED FINISH (COLOR: BLACK)
94

9190 12594
24

2380 2579 3658 2582

TIES
10mmØ RS BARS

1500
4@50mm
2@100mm
SIDEWALK FINISH FLOOR LINE
REST 200mm O.C.
PERIMETER FENCE
DETAILS FRONT ELEVATION)
VERT. BARS SCALE 1:60M

12mmØ RS BARS FENCE POST FENCE WALL


CONCRETE CONCRETE HOLLOW BLOCKS
SMOOTH FINISH PAINTED MASONRY ROUGH PLASTER FINISH

VARIES

1500
SIDEWALK FINISH FLOOR LINE

PERIMETER FENCE
SECTION
DETAILS (HOUSE)
600 SCALE 1:60M

450 REINFORCEMENTS
5-12mmØ RS BARS FENCE POST FENCE WALL
200
SPACED@104mm CONCRETE CONCRETE HOLLOW BLOCKS
SMOOTH FINISH PAINTED MASONRY ROUGH PLASTER FINISH
BOTHWAYS

VARIES
104
450
200
600

1800
SIDEWALK FINISH FLOOR LINE

PERIMETER FENCE
DETAILS (PARKING)
PLAN SCALE 1:60M

DETAIL OF FENCE POST


PERIMETER FENCE
DETAILS (POST)
SCALE 1:16M

CIVIL ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.

PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE 4


CRIS EMANUELLE H. CASTOR PERIMETER FENCE LAYOUT A4 4

PROJECT LOCATION PERIMETER FENCE DETAILS 04 09


EVELYN L. ANTIOQUIA
PRC NO. : 0168420 12/07/26
PTR NO. : BTG 33336550 01/18/24 BARANGAY MAMATID, CABUYAO, LAGUNA ARCHITECTURAL
TIN NO. : 478-509-028-000 09/16/20
GENERAL: TABLE - 1 NOTES ON COLUMNS AND PEDESTALS REINFORCING CONCRETE LINTEL BEAM IN CONCRETE BLOCK WALLS STRUCTURAL STEEL
SCHEDULE OF MINIMUM SLAB REINFORCEMENT A. FOR ALL TIED COLUMNS AND PEDESTALS PROVIDE EXTRA 4 SETS OF TIES AT 100mm O.C.
THE GENERAL NOTES AND SPECIAL REQUIREMENTS ARE SUPPLEMENTAL AND FORM PART OF LINTEL IN BLOCK WALLS ( PER 100mm THICKNESS ) A. MATERIALS
THE PLANS, DRAWINGS AND SPECIFICATIONS, WHERE DETAILS OR REQUIREMENTS ARE NOT THICKNESS MINIMUM TEMPERATURE BARS FOR COLUMN REINFORCEMENTS JUST ABOVE THE FLOOR, JUST BELOW THE GIRDER AND AT
1. STRUCTURAL STEEL - STEEL TO BE USED FOR FABRICATION AND ERECTION
COVERED BY THE PLANS OR SPECIFICATIONS. THESE GENERAL CONSTRUCTION NOTES SHALL 100.00 mm 10 mmØ @ 275 mm EACH WAY CONSTRUCTION JOINTS. CLEAR SPAN L TOTAL LENGTH MIN fc' HEIGHT OF REINFORCEMENT WEIGTH OF OF THIS STRUCTURE SHALL COMPLY WITH ALL THE PERTINENT PROVISIONS
BE USED IN SO FAR AS THEY ARE APPLICABLE TO SATISFY REQUIREMENTS OF GOOD 112.50 mm 10 mmØ @ 238 mm EACH WAY B. COLUMN AND PEDESTAL TIES SHALL BE PROTECTED EVERYWHERE BY COVERING OF A m L + 0.40 MPa LINTEL (cm) LINTEL (lb)
125.00 mm 10 mmØ @ 212 mm EACH WAY BOTTOM TOP OF AISC SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF
CONSTRUCTION PRACTICE. IN CASE OF QUESTIONS ARISING FROM THE INTERPRETATION OF OR CONCRETE CAST MONOLITHICALLY WITH THE CORE OF MINIMUM THICKNESS OF 38mm AND
137.50 mm 10 mmØ @ 188 mm EACH WAY
1.20 1.60 13.8 19.08 1 - 10 mm 1 - 10 mm 170
STRUCTURAL STEEL FOR BUILDINGS AISC - 14TH EDITION.
CONFLICT WITH OTHER DOCUMENTS, THE ATTENTION OF THE OWNER / ENGINEERS MUST 150.00 mm 10 mmØ @ 175 mm EACH WAY NOT LESS THAN 1 13 TIMES MAXIMUM SIZE OF COARSE AGGREGATE. a. STEEL SHAPES
1.50 1.90 13.8 19.08 1 - 10 mm 1 - 10 mm 203
CALLED IN WRITING. 1.80 2.20 13.8 19.08 1 - 10 mm 1 - 10 mm 235 WIDE FLANGE, ANGLES, CHANNELS, PLATES SHALL BE ASTM A36.
E. UNLESS OTHERWISE NOTED IN PLANS, ALL BEDDED SLABS SHALL BE REINFORCED WITH 10 NOTES ON BEAMS AND GIRDERS BUILT UP MEMBERS SHALL BE ASTM A36. SUBSTITUTION SHALL ONLY
mmØ REBAR AT 0.25 m O.C. EACH WAY AT CENTER OF SLAB AND CONSTRUCTION JOINTS A. UNLESS OTHERWISE NOTED ON PLANS, CAMBER ALL BEAMS AND GIRDERS AT LEAST
2.10 2.40 17.2 19.08 1 - 16 mm 1 - 10 mm 266
GENERAL NOTES: 2.40 2.80 17.2 19.08 1 - 16 mm 1 - 10 mm 299 BE ALLOWED IF SUBSTITUTED MATERIALS IS ALSO A36 AND
FOR SAME SHALL NOT BE MORE THAN 6m APART. 6.35mm FOR EVERY 457 CENTIMETERS OF SPAN EXCEPT CANTILEVERS FOR WHICH THE
A. ALL REINFORCING BARS SHALL BE OF INTERMEDIATE GRADE WITH A MINIMUM YIELD 2.70 3.10 17.2 19.08 1 - 20 mm 1 - 10 mm 331 PROVIDED FURTHER THAT SECTION MODULI AREA AND WEIGHT ARE =
F. PROVIDE EXTRA REINFORCEMENTS FOR CORNER SLABS ( TWO ADJACENT DISCONTINUOUS CAMBER SHALL BE AS NOTED IN PLANS OR AS ORDERED BY THE ENGINEER BUT IN NO CASE
STRENGTH OF fy = 276 MPa ( 40,000 psi ) AND A MINIMUM TENSILE STRENGTH OF 483 OR > THAN THE SPECIFIED MATERIAL. REQUEST FOR SUBSTITUTION
EDGES AS SHOWN BELOW. LESS THAN 19.05mm FOR EVERY 3m OF FREE SPAN.
3.00 3.40 17.2 29.08 2 - 16 mm 1 - 10 mm 544
MPa ( 70,000 psi ) EXCEPT AS INDICATED. 3.30 3.70 17.2 29.08 2 - 16 mm 1 - 10 mm 592 SHALL BE ACCOMPLISHED WITH DETAILED COMPUTATIONS FOR THE
5 - 10mm BARS @ 0.20 m B. TYPICAL BAR BENDING AND CUTTING DETAILS FOR BEAMS AND GIRDERS SHALL BE AS
B. ALL REINFORCING BAR SIZE 12mm OR BIGGER SHALL BE DEFORMED IN ACCORDANCE 3.60 4.00 17.2 29.08 2 - 16 mm 1 - 10 mm 640 ABOVE MATERIAL.
O.C. BOTTOM BARS
WITH ASTM - A615. BARS SMALLER THAN 12mm MAY BE PLAIN BARS. FIG. 2 SHOWN IN FIG. 6, FOR FLAT SLABS AND SLAB BENDS REFER TO PLAN. b. BOLTS
C. BARS OF REINFORCED CONCRETE EXPOSED TO THE WEATHER SHALL BE PREFERABLY BE SEE TABLE"A" ALL BOLTS, NUTS AND WASHERS SHALL CONFORM TO A307 OR A325
20 BAR DIA. LAPPED
PROTECTED AT LEAST 38mm AND IN NO CASE LESS THAN 25mm CONCRETE COVER. THIS 5 - 10mm BARS @ 0.20 m
FOR LENGTH OF SPLICE ON COMPRESSION BARS UNLESS OTHERWISE INDICATED. ANCHOR BOLTS SHALL LIKEWISE BE
EMBEDMENT
PROVISIONS MAYBE WAIVED WHEN ADEQUATE WATERPROOFING IS PROVIDEDBUT SHALL NOTES ON FOOTINGS O.C. TOP BARS L1 / 5 L1 / 4 L2 / 4 L2 / 4 L3 / 4 OF EQUAL STRENGTH AS A325 BOLTS OF SAME SIZE.
IN NO CASE LESS THAN 20mm. 3/4 THE EMBEDMENT
A. CONTRACTOR SHALL REPORT TO ENGINEER ACTUAL UNUSUAL SOIL CONDITIONS UNCOVERED c. WELDS
LENGTH IN TABLE "A"
D. IN THE INTERPRETATION OF DRAWINGS, INDICATED DIMENSIONS SHALL GOVERN AND AND CONFIRM ACTUAL BEARING CAPACITY OF SOIL IN WRITING BEFORE DEPOSITING TOP REINFORCEMENT ALL WELDS SHALL BE IN ACCORDANCE WITH AWS STRUCTURAL
DISTANCES OR SIZES SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. CONCRETE. 19.05 mm CLEAR WELD CODE D1-1 LATEST REVISION FRO SHIELDED METAL ARC
WHEN COUNTED
E. IN REFERENCE TO OTHER DRAWINGS, SEE ARCHITECTURAL DRAWINGS FOR DEPRESSIONS B. FOOTING SHALL BE AT LEAST 1.50m BELOW FINISHED GRADE LINE UNLESS OTHERWISE FOR COMPRESSION WELDING PROCESS, ELECTRODES E - 70 SHALL CONFORM TO AWS
IN FLOOR SLABS, OPENINGS IN WALLS AND SLABS, INTERIOR PARTITIONS, LOCATION OF INDICATED. EXTEND 20 BAR AS-1 OR LATEST EDITION. SUBMERGED ARC WELDING PROCESS

60
DIA. BEYOND OPPOSITE BOTTOM REINF.
DRAINS, ETC. C. UNLESS OTHERWISE SPECIFIED, ALL FOOTINGS SHALL REST ON DENSE SAND OR VERY HARD MAYBE USED AT THE OPTION OF FABRICATION UPON THE APPROVAL

°
FACE OF SUPPORT 19.05 mm CLEAR
F. IN CASE OF DISCREPANCIES AS TO THE LAYOUT DIMENSIONS AND ELEVATIONS BETWEEN CLAY. THIS MAY SOMETIMES REQUIRE OVEREXCAVATION ABOUT 1.00m FROM PRESCRIBED OF ENGINEER.
HEIGHT OF LINTEL
THE STRUCTURAL PLANS AND OTHER DRAWINGS, THE CONTRACTOR SHALL NOTIFY BOTH BOUNDARY LEVEL. SUCH OVEREXCAVATION SHALL BE REPLACED WITH WELL COMPACTED 10mm
EXTERIOR GIRDER 0.10
THE STRUCTURAL ENGINEERS AND OWNER'S REPRESENTATIVE OF SITE ENGINEER IN CRUSHED ROCK BACKFILL. COMPACTION SHALL BE 95% OF MDD BASED ON ASTM D698. EXTERIOR COLUMN INTERIOR COLUMN SUPPORT B. QUALITY CONTROL
WRITING BEFORE PROCEEDING WITH THE AFFECTED WORK. SUPPORT SUPPORT
D. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE 0.075m CLEAR FOR 0.20
1. REFER TO SPECIFICATIONS FOR QUALITY CONTROL TESTING

L1

L2

L3
FIG. 7
CONCRETE DEPOSITED AGAINST THE GROUND AND 0.05m FOR CONCRETE DEPOSITED SPAN L REQUIREMENTS.
SEE TABLE "B" FOR LENGTH FIG. 5
NOTE ON CONCRETE MIXES AND PLACING AGAINST FORMWORK. SEE TABLE"B"
OF LAPPED SPLICE 2. STEEL SHAPES
L + 0.40
A. THE CONTRACTOR SHALL SUBMIT THE SCHEDULE OF POURING AND LOCATIONS AT FOR LENGTH OF
EMBEDMENT EVERY BATCH OF STRUCTURAL STEEL SHAPE FOR FABRICATION
CONSTRUCTION JOINTS TO THE FIELD ENGINEER AT LEAST FOUR ( 4 ) DAYS PRIOR TO THE SHALL HAVE THE MANUFACTURER'S MILL CERTIFICATE SHOWING
TABLE "A"
POURING FOR APPROVAL.
B. WET CURING OF CONCRETE SHALL BE CONTINUOUS FOR MINIMUM PERIOD OF TEN ( 10 )
MASONRY UNITS TENSION BARS EMBEDMENT LENGTH & LAP SPLICES THEIR CHEMICAL AND PHYSICAL PROPERTIES.
IN CENTIMETERS 3. WELD FINISH
DAYS IMMEDIATELY AFTER POURING. SCHEDULE OF CHB & CERAMIC BLOCK REINFORCEMENT ALL WELDS SHALL FREE FROM UNDERCUTS, PINHOLES AND CRACKS.
C. THE CONTRACTOR SHALL FURNISH AND MAINTAIN ADEQUATE FORMS FOR SHORINGS BAR SIZE fc' = 20.7 MPa fc' = 17.2 MPa
BLOCK REINFORCEMENT NON-DESTRUCTIVE TESTING (DYE PENETRANT) MAYBE CONDUCTED
NOTES: DEFORMED
UNTIL THE CONCRETE MEMBERS HAVE ATTAINED THEIR SUFFICIENT STRENGTH FOR THICKNESS HORIZONTAL VERTICAL EMBEDMENT LAP EMBEDMENT LAP
A. MINIMUM LAPS AT SPLICE = 0.25m NOTES ON EMBEDDED PIPES IN CONCRETE AT WELDS DEEMED NOT IN CONFORMITY WITH THE SPECIFICATION
WORKING CONDITION ANTICIPATED. B. PROVIDE RIGHT ANGLED REINFORCEMENT AT 10 mm 30 30 30 30 AND SHALL BE TO CONTRACTOR'S ACCOUNT.
75 mm 10 mmØ AT 10 mmØ @ 600 mm O.C. A. ALL EMBEDDED PIPES FOR UTILITIES, ETC. SHALL BE MAXIMUM 100mmØ SINGLE RIGID
D. ALL CONCRETE WORKS SHALL BE DONE IN ACCORDANCE WITH THE ACI 318 - 14 EVERY CORNERS 0.92m LONG. 12 mm 30 36 30 30
100 mm 10 mmØ @ 600 mm O.C.
C. WHERE CHB OR CERAMIC BLOCK WALLS GALVANIZED IRON PIPES UNLESS OTHERWISE SPECIFIED OR APPROVED IN WRITING BY THE
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE AND ALL STRUCTURAL 3 LAYER 16 mm 36 45 30 43
150 mm 12 mmØ @ 600 mm O.C. ADJOIN COL., RC BEAMS & WALL DOWELS WITH 20 mm 36 55 39 61
STRUCTURAL ENGINEER. C. FABRICATION
STEEL WORK IN ACCORDANCE WITH THE LATEST EDITION OF THE A.I.S.C. SPECIFICATIONS 200 mm 12 mmØ AT 12 mmØ @ 600 mm O.C. THE SAME AS VERT. OR HOR. REINFORCEMENT 22 mm 52.5 62.5 57.5 65 B. SUCH PIPES WHEN SO EMBEDDED SHALL NOT TAKE UP MORE THAN FOUR ( 4 ) PERCENT OF 1. WELDS
IN SO FAR AS THEY DO NOT CONFLICT WITH THE REQUIREMENTS OF THE NATIONAL EVERY SHALL BE PROVIDED.
3 LAYER
25 mm 56 95 62 105 THE GROSS AREA OF THE CONCRETE MEMBER. ALL WELDED CONNECTIONS SHALL DEVELOP THE FULL STRENGTH OF
STRUCTURAL CODE OF THE PHILIPPINES AND LOCAL CODES. 28 mm 71 121 77 131 THE MEMBERS CONNECTED.
E. A.C.I. REFERS TO AMERICAN CONCRETE INSTITUTE, A.I.S.C. TO AMERICAN INSTITUTE OF 32 mm 93 158 101 172
a. LENGTH OF WELDS:
STEEL CONSTRUCTION AND A.S.T.M. TO AMERICAN SOCIETY FOR TESTING MATERIALS. PROVIDE STIFFENER COLUMN COLUMNS AND BEAMS AT EVERY 3000mm ON CENTER FOR CHB 36 mm 151 179 128 218
THE MINIMUM LENGTH OF FILLET SHALL NOT BE LESS THAN 4 TIMES
F. UNLESS OTHERWISE INDICATED IN PLANS OR NOTED IN THE SPECIFICATIONS, THE WALL, USE 4 - 12mmØ VERTICAL BARS WITH 10mmØ TIES @ 300mm ON CENTER. THE NOMINAL SIZE WHERE INTERMITTENT WELDS MAY BE USED, THE
MINIMUM 28th DAY CYLINDER COMPRESSIVE STRENGTH OF CONCRETE SHALL BE AS TABLE "B" NOTES ON COMPACTED FILL LENGTH OF SEGMENT SHALL NOT BE LESS THAN 4 TIMES THE WELD
FOLLOWS: COMPRESSION BARS EMBEDMENT LENGTH & LAP SPLICES A. FILL, BACKFILL AND SUB-GRADES UNDER SLABS AND FOOTINGS SHALL BE COMPACTED TO A SIZE WITH A MINIMUM OF 40mm.
1. FOOTINGS, FOOTING TIE BEAMS: fc' = 20.7 MPa ( 3000 psi ) NOTES ON CONCRETE WALLS IN CENTIMETERS MINIMUM 95% OF MAXIMUM DRY DENSITY BASED ON ASTM D-698 FOR EVERY LIFT IN b. END RETURN OF FILLET WELDS
2. COLUMN, PEDESTALS: fc' = 20.7 MPa ( 3000 psi ) A. ALL WALLS SHALL BE REINFORCED ACCORDING TO THE FOLLOWING SCHEDULE OF WALL
BAR SIZE fc' = 20.7 MPa fc' = 17.2 MPa ACCORDANCE WITH THE SPECIFICATIONS. SIDE OR END FILLET WELDS TERMINATING AT END OR SIDES SHALL
3. BEAMS AND GIRDERS: fc' = 20.7 MPa ( 3000 psi ) REINFORCEMENT UNLESS OTHERWISE INDICATED IN THE PLANS.
DEFORMED B. MAXIMUM LIFT THICKNESS FOR COMPACTION SHALL BE 250mm. BE RETURNED CONTINUOUSLY FOR A DISTANCE NOT LESS THAN
4. NON-LOAD BEARING WALL PARTITION, CATCH BASIN, SIDEWALK (IF ANY): fc' = EMBEDMENT LAP EMBEDMENT LAP
SCHEDULE OF CHB & CERAMIC BLOCK REINFORCEMENT C. MONITOR QUALITY OF COMPACTION USING AN INDEPENDENT TESTING LABORATORY USING TWICE THE NOMINAL SIZE OF WELD.
17.2 MPa ( 2500 psi ) 10 mm 20 30 20 30 ASTM D-1556 CRITERIA.
WALL REINFORCEMENT VERTICAL c. USE E70 ELECTRODES FOR ALL WELDS IN STRUCTURAL STEEL.
REMARKS 12 mm 20 30 21 34
THICKNESS HORIZONTAL VERTICAL SECTIONS D. OVERSIZED BOULDERS UNDERNEATH FOOTINGS SHALL BE REMOVED TO PROVIDE FULL 2. BOLTS
G. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION, 16 mm 23 32.5 26 42.5
100 mm 10 mmØ @ 250 mm O.C. 10 mmØ @ 300 mm O.C. HOR. BARS @
VERT. STAG.
20 mm 28 37.5 31 50
BEARING. CAVITY OF VOID EXPOSED SHALL BE BACKFILLED WITH LEAN CONCRETE. a. MINIMUM EDGE DISTANCE:
RE-HANDLING OR FLOWING. PLACING SHALL BE DONE PREFERABLY WITH BUGGIES, BARS
125 mm 10 mmØ @ 200 mm O.C. 10 mmØ @ 250 mm O.C. CENTER, VERT. 22 mm 25 45 27.5 57.5 THE MINIMUM EDGE DISTANCE OF BOLTS SHALL CONFORM TO THE
BUCKETS OR WHEELBARROWS. NO CHUTE WILL BE ALLOWED EXCEPT TO TRANSFER 150 mm 12 mmØ @ 250 mm O.C. 12 mmØ @ 300 mm O.C. BARS STAG. 25 mm 37 51 41 67.5
175 mm 12 mmØ @ 220 mm O.C. 12 mmØ @ 250 mm O.C. OUTSIDE
HOR. BARS
REQUIREMENTS OF AISC STEEL MANUAL 8TH EDITION. THE MAXIMUM
CONCRETE FROM HOPPERS TO BUGGIES, WHEELBARROWS OR BUCKETS IN WHICH CASE VERT. 28 mm 42 57.5 47 75
200 mm 10 mmØ @ 250 O.C.E.F 10 mmØ @ 300 O.C.E.F. BOTH FACES BARS EDGE DISTANCE FROM BOLT CENTER SHALL BE 12 TIMES THICKNESS
THEY SHALL NOT EXCEED SIX ( 6 ) METERS IN AGGREGATE LENGTH. 225 mm 10 mmØ @ 200 O.C.E.F. 10 mmØ @ 250 O.C.E.F. HOR. BARS SHALL 32 mm 46 64 52 85
OF PLATE BUT NOT TO EXCEED 150mm.
H. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS 250 mm 12 mmØ @ 300 O.C.E.F. 12 mmØ @ 350 O.C.E.F. BE OUTSIDE HOR. BARS \
36 mm 51 72
NOTES ON SLAB ON GRADE b. MINIMUM PITCH
UNLESS AUTHORIZED IN WRITING BY THE DESIGNER AND ONLY FOR UNUSUAL
REINFORCING BARS SHALL HAVE 25mm MINIMUM CLEAR CONCRETE COVER FROM FACE OF A. SLAB SHALL BE PLACED WITH A MAXIMUM WATER CEMENT RATIO OF 0.42. ANY ON CENTER SPACING OF BOLTS SHALL NOT BE LESS THAN 3 TIMES
CONDITIONS WHERE VIBRATION IS EXTREMELY DIFFICULT TO ACCOMPLISH. ANY POURING
WALL EXCEPT FOR WALLS IN CONTACT WITH THE GROUND WHERE A MINIMUM OF 62.5mm DISCREPANCY IN SUMP OR WORKABILITY SHALL BE REMEDIED BY THE USE OF PLASTICIZER. THE NOMINAL DIAMETER.
REQUIRES ONE SPARE VIBRATOR ALWAYS. C. IF BEAM REINFORCING BARS END IN A WALL, THE CLEAR DISTANCE FROM THE BAR TO THE
SHALL BE PROVIDED, AND FOR EXPOSED FACES OF FORMED WALLS WHERE THE MINIMUM B. ADDITION OF FLY ASH TYPE "F" IS REQUIRED TO MAXIMUM OF 15% OF CEMENT WEIGHT. 3. TOLERANCES
I. SAMPLING FOR COMPRESSIVE STRENGTH TESTS SHALL BE MADE IN ACCORDANCE WITH FARTHER FACE OF THE WALL SHALL NOT BE LESS THAN 25mm. EMBEDMENT LENGTH SHALL
SHALL BE 50mm CLEAR. C. SLABS SHALL CAST STRAIGHT TO FINISH. OVERTROWELLING SHALL BE DONE USING SOME VARIATIONS EXPECTED IN THE FINISH OVERALL DIMENSIONS OF
SPECIFICATIONS BUT NOT LESS THAN I SET FOR EACH DAY OF POUR. BE AS SHOWN IN TABLE "A" FOR TENSION BARS AND TABLE "B" FOR COMPRESSION BARS.
B. CARRY VERTICAL BARS AT LEAST 600mm ABOVE FLOOR LEVEL TO PROVIDE FOR SPLICES, HELICOPTER TROWEL. FRAMES SHALL NOT EXCEED THE ROLLING TOLERANCES FOR CROSS
J. PULVERIZED FLY ASH ( PFA ) MAY BE SUBSTITUTED TO MAX 15% BY WEIGHT OF D. IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USE 25mm DIAMETER BAR
WHEN NECESSARY STOP AT 50mm BELOW TOP SLAB OR SOLID BAND WHERE THE WALL D. BROADCAST OF CEMENT POWDER SHALL NOT BE ALLOWED DURING FINISHING OPERATIONS. SECTIONAL DIMENSIONS, CAMBER AND SWEEP PERMITTED UNDER ASTM
ORDINARY PORTLAND CEMENT TYPE 1. THIS REQUIREMENT IS ONLY MANDATORY FOR SEPARATORS SPACED ABOUT 90 CENTIMETERS ON CENTER. IN NO CASE SHALL THERE BE
ENDS. VERTICAL AND HORIZONTAL BARS SHALL BE SPLICED BY LAPPING A DISTANCE EQUAL SPECIFICATION A36.
MAT FOUNDATION FOR CCT AND BBT TANKS AND IS OPTIONAL ELSEWHERE. STRENGTH LESS THAN TWO ( 2 ) SEPARATORS BETWEEN LAYERS OF BARS.
AND WORKABILITY REQUIREMENTS NEED TO SATISFIED IRRESPECTIVE OF WHETHER OF 40 BAR DIAMETERS AND WIRED SECURELY WITH NO. 16 G.I. WIRE PROVIDED THAT SPLICES IN
E. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS OR STEEL SHAPES SHALL BE AS D. ERECTION
PFA HAS BEEN USED OR NOT. ADJACENT BARS ARE STAGGERED AT LEAST 1.60m O.C. (SEE FIG. 3)
SHOWN IN FIG. 6. 1. BRACING
40 DIA. b

NOTES ON CONCRETE SLABS 1.60 MIN THE FRAME OF STEEL STRUCTURE SKELETON SHALL BE CARRIED UP TRUE
1.60m O.C.

SEE NOTE
A. ALL SLAB REINFORCEMENT SHALL BE 20.0mm CLEAR MINIMUM FROM BOTTOM AND FROM 40 DIA. b NOTES ON EQUIPMENT & MACHINERY LAYOUT AND PLUMB, WITHIN THE LIMITS DEFINED IN SECTION 7(h) OF AISC CODE OF
TOP OF SLAB. WEB BARS NOTE: A. CONTRACTOR SHALL REFER TO OWNER FURNISHED EQUIPMENT DIAGRAMS AND LAYOUT TO STANDARD PRACTICE. TEMPORARY BRACING SHALL BE PROVIDED TO
B. UNLESS OTHERWISE DETAILED, IN CONTINUOUS SLAB HAVING SAME REINFORCEMENT SEE NOTE 18.75 mm CLEAR FOR JOIST RESIST ALL LOADS INCLUDING ERECTION EQUIPMENT.
37.50 mm CLEAR FOR BEAMS VERIFY WETHER DISCREPANCIES, THE OWNER AND THE ENGINEER SHOULD BE NOTIFIED IN
RUNNING IN ONE DIRECTION, REINFORCING BARS SHALL BE BENT UP, EXTENDED, OR CUT AS
h

FIG. 3 FIG. 6 & GIRDERS WRITING BEFORE PROCEEDING WITH ANY AFFECTED WORK. 2. ALIGNMENT
0.60

FOLLOWS: L1 / 3 L2 / 4 L2 / 4 L3 / 4 L4 25 mm NO RIVETING, PERMANENT BOLTING OR WELDING SHALL BE DONE UNTIL


SEPARATOR STRUCTURE HAS BEEN PROPERLY ALIGNED.
FLOOR LEVEL, FFL. SEE NOTE b
3. SAGRODS AND CROSS BRACING SHALL BE INSTALLED AND TIGHTENED
2 EDGE BARS BEFORE INSTALLATION OF ROOFING OR WALL CLADDING.
F. WHEN A BEAM CROSSES A GIRDER, REST BEAM BARS ON TOP OF GIRDER BARS, BEAM
C. UNLESS OTHERWISE NOTED IN THE PLAN, ALL OPENINGS IN WALLS 250mm OR LARGER
REINFORCING BARS SHALL BE SYMMETRICALLY ABOVE THE CENTER LINE WHENEVER E. PAINTING AND SURFACE PREPARATION
SHALL BE REINFORCED AROUND WITH 2 - 20mm BARS FOR 225mm, 175mm, 150mm WALLS;
FIG. 1 POSSIBLE. 1. STEEL TO BE USED FOR ERECTION OF THIS STRUCTURE SHALL BE PAINTED
USE 2 - 12mm BARS ( SEE Fig. 5 ). ALL WALLS SPANNING OPENINGS SHALL HAVE VERTICAL CONTRACTOR MUST VERIFY ALL DIMENSIONS ON SITE
L1 / 3 L1 / 5 L2 / 5 G. GENERALLY NO SPLICE SHALL BE PERMITTED AT POINTS WHERE CRITICAL BENDING STRESS WITH ONE ( 1 ) SHOP COAT OF RED OXIDE PAINT AND ITS SURFACE
REINFORCEMENTS BENT TO U - FORM LIKE STIRRUPS AND SPACED ACCORDING TO THE CONTRACTOR MUST SUBMIT MATERIAL SAMPLES TO ARCHITECT
L1 L2 L3 L4 OCCUR, SPLICES WHERE SO PERMITTED SHALL BE AS INDICATED IN TABLE "A" AND "B". PREPARED IN COMPLIANCE WITH THE SPECIFICATIONS.
SCHEDULE UNLESS OTHERWISE NOTED ( SEE SECTION A OF FIG. 4).
WELDED SPLICES SHALL DEVELOP IN TENSION AR LEAST 125% OF THE SPECIFIED YIELD CONTRACTOR MUST SUBMIT SHOP DRAWINGS TO ARCHITECT 2. CONTRACTOR TO VERIFY WITH REPRESENTATIVES - PAINTING AND
C. IF SLAB ARE REINFORCED BOTHWAYS, BARS ALONG THE SHORTER SPAN SHALL BE PLACED STRENGTH OF THE BAR. NO MORE THAN 50% OF THE BARS ANY ONE SECTION SHALL BE SURFACE PREPARATION SPECIFICATION BEFORE PROCEEDING WITH WORK.
2 - BARS
BELOW THOSE ALONG THE LONG SPAN AT THE CENTER AND OVER AT THE SUPPORTS. FOR U - FORM ALLOWED TO BE SPLICED THEREIN.
0.40

THE REINFORCING BARS NEAR THE SUPPORTS, THE SPACING OF THE BARS AT COLUMN
STRIPS SHALL BE APPROXIMATELY ONE AND ONE HALF ( 1 12 ) THAT IN THE MIDDLE OPEN
STRIPSBUT NO CASE GREATER THAN TWO AND ONE HALF (2 12 ) TIMES THE SLAB THICKNESS FIG. 4
NOR 45 CENTIMETERS..
2 - BARS
D. TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE FACE IN TENSION U - FORM
0.40

A
0.40

AND SHALL NOT BE LESS THAN 0.0025 x BT. ( See TABLE - 1 )


0.40

CIVIL ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.

PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE 1


S1 3
CRIS EMANUELLE H. CASTOR
GENERAL NOTES 05 09
PROJECT LOCATION EVELYN L. ANTIOQUIA
PRC NO. : 0168420 12/07/26
PTR NO. : BTG 33336550 01/18/24 BARANGAY MAMATID, CABUYAO, LAGUNA STRUCTURAL
TIN NO. : 478-509-028-000 09/16/20
y 1 2 3 4 y' y 1 2 3 4 y' y 1 2 3 4 y'

12594 12594 12594


2425 3196 3395 2575 1000 2425 3196 3395 2575 1000 2425 3196 3395 2575 1000

x' x' x'

1000

1000

1000

1000

1000

1000
C1 - F1 C1 - F1 C1 - F1 C1 - F1 C1 - F1 C1 - F1 C1 - F1 C1 - F1 C1 - F1

WF - 1 WF - 1 WF - 1
TB - 1 TB - 1 TB - 1 TB - 1 TB - 1 RB - 1 RB - 1 RB - 1 RB - 1
F F F

2575

2575

2575
RB - 1

RB - 1
WF - 1

WF - 1

TB - 1

TB - 1
3076

3076

3076

RB - 1
WF - 1

RB - 1

RB - 1
TB - 1

TB - 1
C1 - F1 C1 - F1 C1 - F1 C1 - F1

E C1 - F1 C1 - F1 C1 - F1
E C1 - F1 C1 - F1 C1 - F1
E RB - 1
C1 - F1 C1 - F1
WF - 1 WF - 1 SLAB ON FILL
100mm THK. + FIN. WITH 10mm Ø TEMP. TB - 1 TB - 1 TB - 1 TB - 1 RB - 1 RB - 1 RB - 1 RB - 1

D D D

RB - 1

RB - 1
WF - 1

TB - 1

TB - 1
1350

1350

1350
BARS@350mm O.C. EACH WAY

WF - 1
WF - 1

RB - 1

C C C
WF - 1

WF - 1
C1 - F1 C1 - F1 C1 - F1 C1 - F1
11695

11695

11695
WF - 1

RB - 1

RB - 1

RB - 1
TB - 1

TB - 1

TB - 1

RB - 1

RB - 1
WF - 1

WF - 1

TB - 1

TB - 1
4216

4216

4216
2575

2575

2575
12822

12822

12822
WF - 1

C1 - F1 C1 - F1
WF - 1

B B B RB - 1 RB - 1

RB - 1
TB - 1
WF - 1 TB - 1 TB - 1
WF - 1
C1 - F1 C1 - F1 C1 - F1 C1 - F1

A WF - 1
WF - 1
A TB - 1 A RB - 1

C1 - F1 C1 - F1

SEE STAIR DETAILS SEE STAIR DETAILS SEE STAIR DETAILS


3403

3403

3403
5322

5322

5322
x x x

5621 6973 5621 6973 5621 6973


12594 12594 12594

FOUNDATION PLAN TIE BEAM FRAMING PLAN ROOF BEAM FRAMING PLAN
SCALE 1:100 M SCALE 1:100 M SCALE 1:100 M

TIES
1 2 3 4 1 2 3 4 REINFORCEMENTS
10mmØ RS BARS
1000 4@50mm
5 - 12MM Ø REINF. STEEL BAR
2@100mm
SPACED AT 200MM O.C. BOTH WAYS 850
12594 12594 REST 200mm O.C.
6195 6895 6195 6895 200 200 200 200

VERT. BARS
12mmØ RS BARS
HT - 1 TWO LINES OF HT - 2 VERTICAL
F F

200
10mm Ø SAG RODS REINFORCEMENT
AS SHOWN 4-12MMØ RS BARS
GA#24, SS 304 GUTTER, TYPICAL PER BAY GA#24, SS 304 GUTTER,

200
SATIN FINISH SATIN FINISH

1000
300

850
HT - 1

200
TWO LINES OF TIES
10mm Ø SAG RODS LC - 150 x 50 x 1.2mm HT - 2
E AS SHOWN E PURLINS @ 700mm O.C., with 200 10MMØ RS BARS SECTION
600

200
TYPICAL PER BAY 50 x 50 x 5 x 100mm CLIP ANGLE +
HT - 1 450 REINFORCEMENTS
4-10mm Ø MACHINE BOLTS
5-12mmØ RS BARS
D D
7500

7500
200
SPACED@104mm
8292

8292

BOTHWAYS

C C HT - 2
C1F1
HT - 1 TYP. PLAN OF FOOTING

104
450
200
600
LC - 150 x 50 x 1.2mm
HT - 1
PURLINS @ 700mm O.C., with NATURAL GRADE LINE
50 x 50 x 5 x 100mm CLIP ANGLE +

200
HT - 2 TIES
B 4-10mm Ø MACHINE BOLTS
B GA#24, SS 304 GUTTER,
10MM Ø REINFORCED STEEL BAR SPACE AT
PLAN
GA#24, SS 304 GUTTER, 8- 50MM O.C., 10 - 100MM O.C., 4 - 150MM ON
SATIN FINISH

200
SATIN FINISH CN CENTER REST 200MM
HT - 1
A A TYPICAL

150
6195 6896 6195 6896
C2 - F2 DETAILS

150 100 100 100 100 100 150


SCALE 1:100M

1350
1500
12594 12594

ROOF FRAMING PLAN (HT - 1) ROOF FRAMING PLAN (HT - 2)


SCALE 1:100 M SCALE 1:100 M

300
TYPICAL
C1 - F1 DETAILS
SCALE 1:100M

CIVIL ENGINEER PROJECT TITLE SHEET CONTENTS SHEET NO.

FOUNDATION PLAN 2
PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE TIE BEAM FRAMING PLAN S2 3
CRIS EMANUELLE H. CASTOR ROOF BEAM FRAMING PLAN
PROJECT LOCATION ROOF FRAMING PLAN
06 09
EVELYN L. ANTIOQUIA
PRC NO. : 0168420 12/07/26 TYPICAL COLUMN-FOOTING DETAILS
PTR NO. : BTG 33336550 01/18/24 BARANGAY MAMATID, CABUYAO, LAGUNA STRUCTURAL
TIN NO. : 478-509-028-000 09/16/20
3389 TB-1
150 200
C2 - F2
3389 TB-1 WF - 2

C2 - F2
WF - 2

TB - 1
2706 TB-1

WF - 2
TB-1 WF - 2
C2 - F2 150mm thick C.H.B. 200mm thick C.H.B.
TB-1
C2 - F2
WF - 2
TB-1

C2 - F2
C2 - F2
C2 - F2
TB-1 WF - 2

FIN. GRD. LN. (STORE) FIN. GRD. LN. (STORE)


10mm Ø @ EVERY 3rd LAYER, 10mm Ø @ EVERY 3rd LAYER,

WF - 2
C2 - F2

TB - 1
WF - 2
TB-1

C2 - F2
C.H.B. HOR. BARS C.H.B. HOR. BARS
TB-1 WF - 2

C2 - F2
6288
C2 - F2

500

500
TB-1 WF - 2

C2 - F2
10mm Ø @ EVERY 400mm O.C., 10mm Ø @ EVERY 400mm O.C.,
WF - 2
TB-1
VERT. BARS VERT. BARS

C2 - F2
FIN. GRD. LN. (HOUSE) FIN. GRD. LN. (HOUSE)

WF - 2
C2 - F2

TB - 1
TB-1 WF - 2

200

200
C2 - F2
TB-1 WF - 2
NAT. GRD. LN. 10mm Ø @ EVERY 3rd LAYER, NAT. GRD. LN. 10mm Ø @ EVERY 3rd LAYER,

C2 - F2
C2 - F2
WF - 2 C.H.B. HOR. BARS C.H.B. HOR. BARS

12576
TB-1

C2 - F2
TB-1 WF - 2

C2 - F2
C2 - F2

WF - 2
WF - 2

TB - 1
TB-1

C2 - F2

850

850
WF - 2

TB - 1
WF - 2
TB-1

C2 - F2

C2 - F2
TB-1 WF - 2

6288
12mm Ø @250mm O.C. 12mm Ø @250mm O.C.

C2 - F2
C2 - F2

TB-1 WF - 2 W/ 3-10mm Ø TEMP. W/ 3-10mm Ø TEMP.

250

250
WF - 2
C2 - F2 BARS BARS

WF - 2
TB-1

TB - 1
C2 - F2

100

100
TB-1 WF - 2

C2 - F2
11696 100mm THK. WELL-COMPACTED 100mm THK. WELL-COMPACTED

C2 - F2
WF - 2
GRAVEL FILL GRAVEL FILL
400 400
WF
2-
TB
-1

TYPICAL
WF - 1 WF - 2
C2
-F

WALL FOOTING DETAILS


2

SCALE 1:25 M
WF
-2
TB
-1

C2
-F
2

WF
-2
TB

3 EQUAL THREADS
-1

@ 300mm
C2
- F2

t=
C2 - F2 10mm Ø BARS @
10mm Ø @ SPACED AS

1
CENTER OF RUN

00
WF - 2
WF

C2 - F2
SHOWN, NOSING BARS
2-

m
TB
-1

TB - 1

m
2
WF -
C2 - F2
2900

+F
C2
-F2

WF -
2 TB - 1
C2 - F2
2910
PATIO FLOOR LEVEL 4

IN.
WF -
2 TB - 1
WF

C2 - F2
3
-2
TB
-1

WF -
2 TB - 1
F2
C2 -

3 EQUAL RISES,
C2

2
-F

TB - 1
2

2
WF -

800

200±=600
F2
C2 -

WF -
2 TB - 1
1
WF

F2
C2 -
-2
TB
-1

WF -
2 TB - 1
C2 - F2
TOP OF SIDEWALK
C2
-F

TB - 1
2

2
WF -
C2 - F2

WF -
2 TB - 1
10mm Ø @ 300mm O.C.,
WF

C2 - F2
NATURAL GRADE LINE MAIN BARS
-2
TB

250
-1

WF -
2 TB - 1

400
C2 - F2

1 - 10mm Ø
C2

100mm THK. WELL-COMPACTED


-F2

WF -
2 TB - 1
FENCE

150
C2 - F2
GRAVEL FILL
WF -
2 TB - 1
FOUNDATION PLAN
WF

C2 - F2
-2

100 3 - 10mm Ø
TB
-1

WF -
2 TB - 1 SCALE 1:150 M
C2 - F2
C2

PATIO
-F

TB - 1
2

WF-2
C2 - F2

WF -
2 TB - 1
STAIR DETAILS
WF

C2 - F2
2-
TB

SCALE 1:25 M
-1

TB - 1
C2 - F2
WF - 2
400 400
C2
-F

TB - 1
2

WF - 2
C2 - F2

WF -
2 TB - 1
WF

C2 - F2
2-
TB
-1
4
249

WF - 2 TB - 1
C2
-F
2

TB - 1

6832
400 400 400 400

1156
L/4 L/4

200 LENGTH OF BEAM 200

BEAM DETAILS
SCALE 1:16 M

2∠s- 50 x 50 x 3mm THK


1000
DIMENSION (mm) END - 1 MIDSPAN END - 2
5778

HALF TRUSS - 1 DETAILS


SCALE 1:25 M TB - 1
200 x 300
6450

RB - 1

140
1000
200 x 300
2∠s- 50 x 50 x 3mm THK
6388

HALF TRUSS - 2 DETAILS


SCALE 1:25 M

CIVIL ENGINEER PROJECT TITLE SHEET CONTENTS SHEET NO.

PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE FOUNDATION PLAN 3
TIE BEAM FRAMING PLAN
S3 3
CRIS EMANUELLE H. CASTOR
PROJECT LOCATION ROOF BEAM FRAMING PLAN 07 09
EVELYN L. ANTIOQUIA
PRC NO. : 0168420 12/07/26 ROOF FRAMING PLAN
PTR NO. : BTG 33336550 01/18/24 BARANGAY MAMATID, CABUYAO, LAGUNA STRUCTURAL
TIN NO. : 478-509-028-000 09/16/20
LEGEND ELECTRICAL SYMBOLS
PINLIGHT WITH COMPACT FLOURESCENT BULB
WALL BRACKET LAMP WITH COMPACT FLOURESCENT BULB
DUPLEX CONVENIENCE OUTLET
3 CIRCUIT HOMERUN FOR LIGHTING
y 1 2 3 4 y' y 1 2 3 4 y'
3 CIRCUIT HOMERUN FOR APPLIANCE OUTLETS
s-abc THREE GANG SWITCH
12594 12594
2425 3196 3395 2575 1000 2425 3196 3395 2575 1000

x' x'

1000

1000

1000

1000
F F
d d j j
2 4
DIRTY MASTER'S DIRTY MASTER'S
KITCHEN/ KITCHEN DINING KITCHEN/ KITCHEN DINING

2575

2575
ROOM ROOM
GENERAL NOTES AND SPECIFICATIONS
3076

3076
LAUNDRY ROOM s-ij LAUNDRY ROOM
e e
AREA AREA 1. THE ELECTRICAL INSTALLATION SHOWN ON THE PLANS SHALL CONFORM
1
E i i E WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRIC CODE RULES
AND REGULATIONS OF THE LOCAL ELECTRIC COMPANY AND THE LOCAL
c c
GOVERNMENT WHERE THE PROJECT WILL BE CONSTRUCTED.
D D

1350

1350
s-h T&B T&B
s-cde h 2. ALL ELECTRICAL MATERIALS AND EQUIPMENT TO BE USED IN THIS
T&B 5 T&B PROJECT SHALL BE BRAND NEW AND OF APPROVED QUALITY AND BRAND.
C o
C
CASHIER

CASHIER
3 LIVING LIVING 3. ALL WIRING SHALL BE INSTALLED IN STANDARD ELECTRICAL uPVC
s-o
k b ROOM b g g ROOM CONDUIT PIPES RUN EMBEDDED INSIDE THE HOLLOW BLOCKS
11695

11695
LPP s-mn n LPP
BEDROOM BEDROOM AND CONCRETE STRUCTURES SLABS COLUMNS WALLS PARTITIONS AND
4216

4216
2575

2575
OR RUN CONCEALED BETWEEN DOUBLE WALL WOODEN PARTITIONS AND

12822

12822
s-fg
s-k
m INSIDE THE CEILING SPACES WHERE THE USE IF CONCEALED OR EMBEDDED
OFFICE/STORE OFFICE/STORE CONDUIT WIRING IS IMPRACTICABLE METAL MOULDING WIRING MAYBE USED.
f f
a a 4. UNLESS OTHERWISE INDICATED ON THE PLANS THE MINIMUM SIZE OF THE CONDUIT
B s-l l l
s-ab
B AND WIRE TO BE USED SHALL BE 20MMØ SCHED 40 AND 3.5MM² TW 600V INSULATION.
5. WHEREVER REQUIRED AND NECESSARY PULL BOXES AND JUNCTION BOXES
A A OF PROPER SIZES SHALL BE INSTALLED AT A CONVENIENT AND INCONSPICUOUS
LOCATIONS ALTHOUGH SUCH BOXES ARE NOT SHOWN ON THE PLANS NOR
PATIO PATIO MENTIONED ON THE SPECIFICATIONS.
CARPORT CARPORT 6. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE SINGLE PHASE 220V AC
3403

3403
7. MOUNTING HEIGHT OF ELECTRICAL DEVICES SHALL BE AS FOLLOWS

5322

5322
A. WALL SWITCHES 1.37M ABOVE FINISH FLOOR LEVEL
B. CONVENIENCE OUTLETS 0.30M ABOVE FINISH FLOOR LEVEL
C. AIRCONDITIONING OUTLETS 2.00M ABOVE FINISH FLOOR LEVEL
x x D. PANEL BOARD 1.37M ABOVE FINISH FLOOR LEVEL
E. WASHING MACHINE OUTLET 1.50M ABOVE FINISH FLOOR LEVEL
F. KILOWATT HOUR METER 1.85M FROM GROUND TO CENTER OF METER
8. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER OR MASTER ELECTRICIAN
5621 6973 5621 6973

12594 12594

GROUND FLOOR GROUND FLOOR


LIGHTING LAYOUT POWER LAYOUT
SCALE 1:100 M SCALE 1:100 M

SCHEDULE OF LOADS
LINE SIDE LOAD SIDE NO OF NO OF OTHER VA PER AMP SIZE OF BRKS SIZE OF HOMERUN
CRT NO. LOAD DESCRIPTION
PROPERTY LINE
LIGHTS C.O. LOAD CIRCUIT LOAD/CRT F P T WIRE CONDUIT
1 40W LED LAMP 10 400 1.81 50 2 20 2-3.5mm² THHN 20mmØ PVC
NORMAL MANUAL 2 40W LED LAMP 9 360 1.63 50 2 20 2-3.5mm² THHN 20mmØ PVC
SERVICE TRANSFER SERVICE DROP
3 40W LED LAMP 6 240 1.09 50 2 20 2-3.5mm² THHN 20mmØ PVC
M SWITCH
ENTRANCE CAP 4 DUPLEX CONVENIENT OUTLET 10 1,800 8.18 50 2 20 3-3.5mm² THHN 20mmØ PVC
5 DUPLEX CONVENIENT OUTLET 4 720 3.27 50 2 20 3-3.5mm² THHN 20mmØ PVC
DRIP LOOP WIRES 6 SPARE 1 1,500 6.82 50 2 20 3-3.5mm² THHN 20mmØ PVC
100AT TOTAL LOAD OF THE BUILDING 5,020 22.81 AMPERES
G CONDUIT STRAPPED TO LIGHTING AND POWER USE 60 AT, 100AF 220V CIRCUIT BREAKER
CONCRETE POST PANEL BOARD D.F. ( DEMAND FACTOR ) = 75% I T =22.81 x 0.75 = 17.10 AMPERES
GEN SET 2-30mm2 THHN + 1-14mm2 THHN (G)
60AT in 50 mmØ PVC
5500

1 20A 20A 2
WATT HOUR METER GROUNDING WIRE
3 20A 20A 4
ENTRANCE ELL
5 20A 20A 6

PUBLIC ROAD

SINGLE LINE DIAGRAM SERVICE DROP INSTALLATION


SCALE NTS SCALE NTS

REGISTERED ELECTRICAL ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.
LIGHTING LAYOUT
PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE 1
POWER LAYOUT
GENERAL NOTES
E1 1

PROJECT LOCATION LEGENDS/SYMBOLS 08 09


EVELYN L. ANTIOQUIA
SINGLE LINE DIAGRAM
BARANGAY MAMATID, CABUYAO, LAGUNA SERVICE DROP INSTALLATION ELECTRICAL
TAP TO THE
NEAREST
DRAINAGE LINE
2"ØPPR SANITARY PIPE
GENERAL NOTES
4"ØPPR SANITARY PIPE
1
FAUCET 2"Ø PPR PIPE
WASHING 1
2"Ø PPR PIPE
CO ALL WORKS HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF THE
MACHINE PHILIPPINE NATIONAL PLUMBING CODE, THE NATIONAL BUILDING CODE OF THE
KS KS MASTER'S KS KS MASTER'S KS KS MASTER'S
DIRTY FD
KITCHEN/ 1 DINING ROOM DINING ROOM DINING ROOM PHILIPPINES.
2"Ø PPR PIPE
ROOM ROOM ROOM
LAUNDRY 3
"Ø PPR PIPE
4
AREA KITCHEN KITCHEN KITCHEN
4"ØPPR SANITARY PIPE OTHER TRADES SHALL COORDINATE THE DRAWING WITH OTHER TRADE
4"ØPPR SANITARY PIPE CO CO
3
CO 2"ØPPR SANITARY PIPE DRAWINGS AND TECHNICAL SPECIFICATIONS.
4 "Ø PPR PIPE WC WC
4"ØPPR SANITARY PIPE LAV LAV
FD FD
1
2"Ø PPR PIPE
T&B T&B
LAV LAV ALL PIPES SHALL BE INSTALLED AS INDICATED. ANY RELOCATION REQUIRED FOR
WC WC
SEPTIC PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE
CASHIER

CASHIER

CASHIER
LIVING LIVING LIVING
VAULT
ROOM ROOM ROOM DESIGNER.
SHELVES BEDROOM SHELVES BEDROOM SHELVES BEDROOM
ALL MATERIALS TO BE USED SHALL BE NEW AND OF APPROVED TYPE
APPROPRIATE FOR BOTH LOCATION AND INTENDED USE.

CASHIER HOSE BIBB CASHIER CASHIER

19 mm DROP 19 mm DROP 19 mm DROP


LEGEND
PATIO CARPORT PATIO CARPORT PATIO CARPORT LAV LAVATORY SP SOIL PIPE

METER SHUT OFF WC WATER CLOSET CB CATCH BASIN

FD FLOOR DRAIN SH SHOWER HEAD


GV
CV
CO CLEANOUT SV SHOWER VALVE
M

VSTR VENT STACK THRU ROOF SF FAUCET

ST SEPTIC TANK HB HOSE BIBB

WATER SUPPLY ,MAIN PIPE DS DOWNSPOUT MH MANHOLE


FROM SERVICE PROVIDER
HD HOUSE DRAINAGE GV GATE VALVE

KS KITCHEN SINK CV CHECK VALVE

WATERLINE LAYOUT SEWERLINE LAYOUT DRAINAGE LAYOUT


SCALE 1:100 M SCALE 1:100 M SCALE 1:100 M
STEEL REINFORCEMENT
10MM Ø REINF.
STEEL BARS
5000 SPACED AT 300mm
2550 1150 1300 ON CENTER
BOTH WAYS
100mmØ SANITARY PIPE

800

875 600
2300

800

600

500 PLAN
500

FD
CENTER LINE PLAN OF SEPTIC COVER
OF SLOPE SCALE 1: 50 M
P-TRAP
℄ 5000 TYPICAL
WYE

2550 1150 1300 FLOOR DRAIN DETAILS WYE


SCALE NTS

SL DIGESTIVE CHAMBER E LEACHING WELL LEACHING WELL TYPICAL


OP 2400 OP
E SL CLEAN OUT DETAILS
SCALE NTS

MANHOLE
2300

2000

2000

2000

800 x 800
TYPICAL
SL
OP
E OP JOINT CONNECTION DETAILS
SL E 500 SCALE NTS

100 300 100

WYE

PLAN OF SEPTIC VAULT AA


A5 OUTLET INLET

500
SCALE 1: 50 M

5000
2550 1150 1300
500 PLAN

500 10mmØ RSBARS


SPACED AT 300mm
300 ON CENTER
BOTH WAYS
FFL+0.70M

DIGESTIVE CHAMBER LEACHING WELL LEACHING WELL INLET


2200

2 % SLOPE
OUTLET

200
600

2 % SLOPE
2400 1000 1000
GRAVEL
100

BOULDERS
SECTION THRU AA

TYPICAL
CATCH BASIN DETAILS
SCALE NTS

SEPTIC VAULT SECTION


SCALE 1: 50 M

PLUMBING/SANITARY ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.


WATERLINE LAYOUT
PROPOSED CONSTRUCTION OF BUNGALOW RESIDENTIAL BUILDING WITH PARKING SPACE 1
SEWERLINE LAYOUT
DRAINAGE LAYOUT
P1 1

PROJECT LOCATION GENERAL NOTES 09 09


EVELYN L. ANTIOQUIA
LEGENDS/SYMBOLS
BARANGAY MAMATID, CABUYAO, LAGUNA TYPICAL PLUMBING DESIGN PLUMBING