Project: CP03/INW-Infrastructure works phase 1 & O&M Centre

CHECK LIST ACOUSTICAL CEILING


WIR/IRE No.: Checklist No.:
Drawing No.: ITP No.: KSP-FHJ-INW-CMT-ERW-ITP-
Location Area: O&M BUILDING (Highlighted drawings) Date:
S/N ACCEPTANCE CRITERIA YES NO N/A REMARK
ACOUSTICAL CEILING
1 Check Pre-qualification Of Acoustical ceiling material are approved supplier
2 Check the Material approval for Acoustical ceilingmaterial
3 All Shop-drawings of Joint sealant Acoustical ceilingonfirmed and approved.
4 Check the meaterial inspection while arrival approved Acoustical ceiling material @ site

Check the Acoustical ceiling accessories material should be approved before commence the work
5
6 Check the MEP clearance before commencement of Acoustical ceiling work
Verify that surfaces and site conditions are ready to receive work. Correct defects in the
7 substrate before commencing with Acoustical ceiling work.
check the Tools using in Acoustical ceiling is well working condition
8

Site should be ready to receive the Acoustical ceiling material before any delivery to minimize damages
9

Check the all wet area water proof completed & teasted before commencement of acoustical ceiling work
10

Check & Verify that layout of hangers will not interfere with other work.
11
Check the Acoustical ceiling lay out of frame & its accessories as per approved shop drawing (such as flatness,
12 line ,level , etc)
Check the Acoustical ceiling Mock up complete setup as per approved drawing
13

14 Check the Acoustical ceiling Design for maximum deflection of 1/360 of span

15 Check the Acoustical ceiling panels Size and configuration as per the Architectural drawings
Check the acoustical units in place, free from damaged edges or other defects detrimental to
16 appearance and function.

17 Check the Acoustical ceiling Lay directional patterned units with pattern parallel to longest room axis.

18
Check the Install acoustical units level, in uniform plane, and free from twist, warp, and dents.

TOLERANCES
A. Maximum Variation from Flat and Level Surface: 3 mm in 3 m.
19 B. Maximum Variation from Plumb of Grid Members Caused by Eccentric Loads: 2 degrees.

Contractor: FH JV PMCM: F & G Consultant