NAME -

A.

B.

C.

D.
E.

F.
DESIGN OF BOUNDARY WALL

DATA

Height of Column

Centre-centre distance between column

Filling Weight in wall


Grade of Concrete
Grade of Steel

Determination of Thickness of Wall


Minimum Thickness
H/25
L/25

Applying lesser value from L/25 and H/25,


Adopt a thickness

Determination of Slenderness

Effective Height, Hwe

Thus,
Effective Height, Hwe

As per Cl. 32.2.3,


Hwe/t < 30.
Thus, Hwe/t

Hence, it is adequate.
As Hwe/t >12, the wall is slender.

Determination of Design Strength of Wall


As per Cl. 32.2.5,
Design Strength, Pnw =
where, min ex =
ea =
Thus,
Design Strength, Pnw =

For 1m length,
Pnw = 355.725 N/mm > 300 N/mm

Hence, wall can safely carry applied load.

Design of Reinforcement
Maximum spacing, S =
Vertical Ast = (0.0012x1000x60)
Horizontal Ast = (0.020x1000x60)

Providing 10mm dia rebars at 400mm c/c on both faces, vertically and horizonatally.

Capacity Check as per ACI 318

Pnw = 0.286fckAg[1-(kHw/32t)2]

For 1m length,
Hence, OK.
Hw = 1.5 m
1500 mm
5m
L= 5000 mm
900 mm
M30 = 30 N/mm2
Fe500 = 500 N/mm2

100 mm
60 mm
200 mm

t= 60 mm

0.75Hw 1125 mm
0.75L 3750 mm

1125 mm

18.75 < 30

0.3(t-1.2e-2ea)fck
t/20 3 mm As per Cl. 32.2.2
(H2we/2500t) 8.4375 mm

0.3(t-1.2e-2ea)fck 355.725 N/mm

3t ( or 450 mm) 180 mm


72 mm 2

120 mm2

2574000 x 0.609375
1568.53125 kN

313.70625 kN < 355.725 kN (as per IS:456)