CORNING CABLE SYSTEMS

®
SOLO ADSS SAG & TENSION INFORMATION
CCS (2011-02-04) Completed: 8/8/2018
Span/Installation Installation Basis
Enter customer! Customer Tension Sag Sag
Span length (Meters) 200 (Newtons) (Meters) (%)
Span length (Feet) 1.0
Number of fibers 48 Core size: 6 position
Number of fibers per tube 12

Installation Temperature (°C) 23 Electrical Stress Rating


Maximum Temperature (°C) 70 MDPE (12 kV)
Minimum Temperature (°C) -60 TRPE (25 kV) x

Representative Part Number


(for reference only) Cable diameter (nominal) Cable weight (nominal)
048EAA-T3501A20 14 mm 0.55 in 0.16 kg/m 0.10 lb/ft

NESC
Environmental Conditions NESC Heavy NESC Light Special
Medium
x
Default loading values are metric values rounded
Horizontal
Results Tension
Deflection
Sag (Vertical) (1)

(Pounds) (Newtons) (Feet) (Meters) (Feet) (%)


Sagging / Initial Installation 861 3,828 0.00 2.00 6.56 1.0%
Long term 671 2,986 0.00 2.57 8.42 1.3%
Maximum temperature 685 3,046 0.00 2.51 8.25 1.3%
Minimum temperature 653 2,906 0.00 2.64 8.65 1.3%
Environmental loading 2,281 10,147 16.28 7.26 23.83 3.6%
Disclaimers
The values listed herein are:
(a) provided as estimates only
(b) based on data supplied by customer, including environmental conditions the cable may be installed in
(c) assume proper installation, termination, and maintenance by customer within prescribed guidelines and
good commercial practices.
Customer agrees and acknowledges that it is responsible for the safe and proper installation, termination, and maintenance
of products purchased from Corning Cable Systems in accordance with all applicable laws, standards, and specifications.

Customer further represents that it possesses the knowledge, expertise, and experience to properly and safely install,
terminate, and maintain Corning Cable Systems' products.

Improper installation, termination, or maintenance of cables or installation under environmental or other conditions that differ
from those contained in customer's and/or Corning Cable Systems' specifications may result in shortened cable and
component operating lifetimes; damage to cable and components, or failure of the cable or components which may cause
damage to the cable or components, damage to the property of third parties, and personal injury or death.

Tension meets NESC requirements based on cable's Rated Breaking Strength.