QRF NO R0 BLDG BLDG#1 DESIGN HASMUKH

CUSTOMER NAME M/S VEERAL ORGANICS PVT. LTD. CHECKED YB


LOCATION MAHAD, MAHARASTRA DATE 19/04/2023
CONSULTANT SALES ENGG.

TECHNICAL DATA SHEET


TYPE : TCMS-2 Symetrical Frame / Ridge
QTY. OF MEF : Non expandable light end frame WITH CROSS BRACING
WIDTH : 63.000 meter O/O of Steel Line
LENGTH : 68.000 meter O/O of Steel Line
CLEAR HEIGHT : 12.000 meter ALL COLUMN 6.0M RCC COLUMN AND ABOVE STEEL COLUMN
ROOF SLOPE : 1:10
BAY SPACING : 1@7.554 + 7@7.556 + 1@7.554
INT COL SPACING : 1@19.100 + 1@24.800 + 1@19.100
END WALL COL SPACING : 1@6.700 + 8@6.200 + 1@6.700
ROOF SHEETING : SRS 0.475mm thk Colour Galvalume BARE Coated
WALL SHEETING : SWS 0.5mm thk TCT Colour Galvalume RMP Coated
GABLE SHEETING : SWS 0.5mm thk TCT Colour Galvalume RMP Coated
WALL CONDITION
From FFL LVL. SIDE WALL-1 6.00m Height RCC wall & above sheeted
From FFL LVL. SIDE WALL-2 6.00m Height RCC wall & above sheeted
From FFL LVL. END WALL-1 6.00m Height RCC wall & above sheeted
From FFL LVL. END WALL-2 6.00m Height RCC wall & above sheeted

LOADINGS : DL : KN /m2 LL : KN /m2 WS : m/sec AUX : KN /m2 SEISMIC ZONE


0.10 0.57 44 * III
WIND EXPOSURE
C
ADDITIONAL LOADINGS :-
1 100KG/RMT LIVE LOAD ON CABLE TRAY.
2 20KG/SQMT FIRE HYDRANT LOAD CONSIDERED ON ROOF.

DESIGN ACCORDING TO:

Wind Load application as per MBMA-96, Design According to AISC -1989 and Serviceability according to MBMA -1996

MIN THICKNESS CRITERIA :


PRIMARY SECONDARY
MIN THICKNESS(MM) 5.0 1.5 275 GSM

BRACING SYSTEM : ROOF SIDEWALL INTERIOR LINE END WALL


BRACING ROD ROD ROD ROD

FRAMED OPENINGS CANOPY

USES QUANTITY WIDTH HEIGHT QUANTITY(Nos) WIDTH(M) LENGTH(M) EAVE TYPE

CURVED EAVES
RS 1 6.0 6.0 1 3.00 6.200 WITHOUT SOFFIT
CURVED EAVES
RS 0 0.0 0.0 0 0.00 0.0 WITHOUT SOFFIT

Serviceability Criteria(Deflection check) as per MBMA-1996.

Main Frame Rafter Purlins Girts Crane Beam Mezz Beam/ Joist Main Frame With Crane Without Crane

Vertical
L/180 L/150 L/120 L/600 L/240 Lateral Deflection H/100 H/90
Deflection

IMPORTANT NOTES, DEVIATIONS & ASSUMPTIONS:-

1) Framed openings Header & Jamb Considered as HOT ROLLED Member.


2) All columnS support considered as PINNED BASE & Wind Column considered Pinned Base.
3) Rainfall intensity considered for design of gutter &downspout is 100 mm/hour.
4) 1 No Cage Ladder considered for Roof Access
5) Single Galvalume Downtake Pipe is considered at all SW Column Location.
6) All around periphery cable try considered.
QRF NO R0 BLDG BLDG#1 DESIGN HASMUKH

CUSTOMER NAME M/S VEERAL ORGANICS PVT. LTD. CHECKED YB

LOCATION MAHAD, MAHARASTRA DATE 19/04/2023

CONSULTANT 0 SALES ENGG. 0

TONNAGE BREAKUP, ACCESSORIES AND BUYOUTS


WEIGHT
BREAK DOWN
(MT)
Built up-50 ksi 52.12 SSW

HR miscellaneous 7.64

Secondary (Cold-Form) 28.96

Roof sheeting 19.13

Wall sheeting 9.09

Wall accessories 2.40

Anchor bolts 1.17

Cage Ladders 0.77 (1# For Roof access with platform)

Roof monitor (1.5m x 1.5m) Primary 2.94 Total length of Roof monitor considered is 68 m
Secondary 4.97
Sheeting 3.06

Cable tray Supporting Structure HR 0.99 Total length of cable tray considered is 262 m
Secondary 3.72
TOTAL AREA OF THE BUILDING 4304
Hardware(HSB) 2.58 TOTAL STRUCTURAL WEIGHT (KG) 91295.89
TOTAL STRUCTURAL WEIGHT (KG/M2) 21.21
TOTAL BUILDING WEIGHT (KG) 139526.51
TOTAL BUILDING WEIGHT (KG/M2) 32.42
TOTAL 139.5

WEIGHT
TONNAGE BREAKUP FOR PRICING
(MT)
Built up-50 ksi 55.05

HR miscellaneous 9.40

Secondary 37.64

Roof sheeting 19.13

Wall sheeting 12.15

Wall accessories 2.40

Chequered Plate- 5 mm 0.00

Deck Sheet 0.8mm thk 0.00

Anchor bolts 1.17

HSB 2.58

TOTAL 139.5

S.NO BUY-OUT ITEMS

Standard Accessories Bldg-A

( 3 % of Roof Area) GROSS AREA


1 Sky light (1m x 3m) 138 SQM
2 Turbo vents (0.6m DIA ) 36 NOS.
3 Turbo vent FRP Base for SRS 36 NOS.

Roof plan and Wall areas of building as mentioned below.


UNIT : m2 Bldg-A
~ROOF AREA 4301

~CANOPY AREA 20

~WALL AREA 1985

Air Bubble type insulation with Both side Alu. Foil - 8mm thk
UNIT : m2 Bldg-A
~ROOF AREA 4731

~WALL AREA 2184

G.I 75x75x1.6
WELD MESH Area (m2) MT
Sky Lights 152

b) PAINTING:

i) PAINTING : FINISH -2- coat of low VOC epoxy primer (50 micorn DFT) paint proved colour
PRIMARY:
Bldg Tonnage(MT)
A 64.45