MAN TURBO LTD, ZURICH PRESERVATION MAINTENANCE

QUALITY ASSURANCE CHECK LIST


Plant/Anlage : Order/Best. No.: Date:Sep. 30, 2002
Yetagun 2001 N 710 0072 For long term storage Name: A. Haller
Type of machine:
RB 40-5(6) Rev.: 0
Event/ Preservation/Konservierung
Vorg. Period (Weeks/Wochen) Event/Vorgang Preservation/
No. 2 4 8 24 Konservierung

1 x Check generally for evidence of damage Refer to


and moisture contamination, Preservation
represerve where necessary with Procedure
applicable protectives 837 360 990

2 x Inspect external surfaces.


Repair/Replace protection as appropriate.
Check for leakages.

3 x Check that all openings are closed

4 x Ensure that "Notice of Preservation"


tags are in position and correct.

5 x Check exterior levels of preservation


where applied.
Top up as appropriate.

6 x Ensure that all sealing plugs are tight


and that any valves used for isolating
purposes are closed.

7 x Check Nitrogen Purging


Pressure maintained at 3 to 4,5 psig
0,2 to 0,3 barg

8 x Check protection on gauges and


instruments.
Repair/replace where necessary.

3ZQS020930+PreservationChecklist.xls 1 of/von 1