CAT 6A/6 STP cables for data (Use Specific same color for all)

1. 1 cable from every workstation to the server room.


2. 1 cable from every cabin to the server room.
3. 2 cables from the meeting room to the server room.
4. 2 cables from reception to the server room.
5. 4 cables from the conference room to the server room.
6. 1 cable from the TV to the server room.
7. 2 cables from printers to the server room.

CAT 6A/6 STP cables for Wi-Fi devices (Use Specific same color for all)

1. 1 cable from reception to the server room.


2. 1 cable from the conference room to the server room.
3. 4 cables from the Workstation corners to the server room.
4. 1 cable from workstation middle to server room.

CAT 6A/6 STP cables for voice (Use Specific same color for all)

1. 1 cable from every workstation to the server room.


2. 1 cable from every cabin to the server room.
3. 1 cable from the meeting room to the server room
4. 2 cables from reception to the server room
5. 2 cables from the conference room to the server room.
6. 1 cable from the pantry to the server room.

CAT 6A/6 STP Cable for CCTV (Use Specific same color for all)

1. 1 cable from outside of the office to the server room.


2. 2 cables from the reception area to the server room
3. 1 cable from the conference room to the server room
4. 4 cable workstation area to the server room
5. 1 cable from the server room gate inside to the server room
6. 1 cable from every cabin to the server room.

CAT 6A/6 STP for biomatrix machine (Use Specific same color for all)

1. 2 cables from the biomatrix machine position to the server room.


2. 1 cable from the biomatrix machine position to the reception desk.
3. 1 cable from the biomatrix machine position to magnetic lock. (Glass door on the upper side)

HDMI & USB Cables

1. 2 4k HDMI cables from the TV to the Conference room table.


2. 2 USB 3.0 cable from TV to Conference room table. (Male pin on tv side)
3. 1 USB 3.0 Cable from Conference room to TV. (Male pin on table side)

Note.

1. Add 2 extra blank 1-inch pipes for wiring in the conference room for the future.
2. Select different colors for Data, WIFI, Voice & CCTV.
3. Please ensure all Cat 6 cable lengths will be enough & same in the server room.
Power Socket

1. 5-amp 2 power socket in every workstation or add 3. (1 extra for future)


2. 5-amp 4 power socket in every cabin.
3. 5-amp 8 power socket in the conference room.
4. 5-amp 4 power socket near tv.
5. 5-amp 10 power socket in the server room.
6. 5-amp 4 socket near printer.
7. 16-amp 1 power socket near the tv.
8. 16-amp 2 power socket near printer.
9. 16-amp 3 power socket in pantry.
10. 16-amp 4 power socket in server room.