Low voltage

Acti 9
the efficiency you deserve

Gulf Catalogue
2014 / 2015
5 generations
of industry experience and 21 new patents
make Acti 9 the new reference in low-voltage
modular systems

2 Acti 9 | Catalogue 2014


Acti 9 Content

Page
General Principle of catalogue numbers, protection (Acti 9) 7
Circuit protection Choice of circuit protective devices 8
Circuit breaker panorama 10

A
Neutral breaking circuit breakers
iDPN and iDPN N A-2
Circuit breakers up to 63 A
iK60 (B curve) A-4
iK60 (C curve) A-7
iC60N A-9
iC60H A-12
iC60L A-16
Circuit breakers up to 125 A
C120N A-20
C120H A-23
High performance circuit breakers
NG125a A-27
NG125N A-29
NG125H A-31
NG125L A-33
Direct current circuit breakers
C60H-DC A-35
Motor protection circuit breakers
i60CLMA A-38
NG125LMA A-41
Residual current devices
B
Choice of earth leakage protection devices B-2
Overview of the earth leakage protection product range B-4
Residual current circuit breakers
iID B-6
iID K B-11
RCCB-ID 125 A B-13
RCCB-ID type B B-15
Add-on residual current devices for circuit breakers
Vigi iC60 B-17
Vigi C120 B-22
Vigi NG125 B-27
Vigi modules and residual current devices i DPN B-33
Residual current devices
iDPN Vigi B-35 C
iC60 RCBO B-38
Load protection LV surge arresters
(surge arrester) iPF C-2
iPRD C-5
iQuick PRD C-8
iQuick PF C-11

D
Surge arresters for telephon and informatic networks
iPRC/iPRI C-13
Surge arresters for photovoltaic installations
iPRD-DC PV (white product) C-15
Disconnection Switch-disconnectors
iSW (white product) D-2
Trip switch-disconnectors
NG125NA D-7

Acti 9 | Catalogue 2014 3


4 Acti 9 | Catalogue 2014
Acti 9 Content

Install, connection,
power distribution
Accessorisation/Auxiliarisation
Accessories/ Auxiliarisation iC60, iID, iSW-NA, iDPN Vigi, E-2 E
Reflex iC60, RCA, ARA
Accessories and Auxiliaries for C120 and Vigi C120 devices E-7
Accessories and Auxiliaries for C60H-DC device E-8
Accessories and Auxiliaries for iSW 40 and NG125 devices E-9
Circuit breakers and residual current devices accessories
Accessories for iC60, iID, iSW-NA, Reflex iC60, RCA, ARA E-10
Accessories for C120, iSW and C60H-DC devices E-15
Acti 9 comb busbars E-18
Distribloc 63 A E-22
Multiclip 80 A E-24
Accessories for NG125 devices E-26
Connection comb busbars for C120 and NG125 E-28
iDPN Comb busbar E-29
Accessories and Auxiliaries for iDPN E-31
Supervision and switchboard Acti 9 control system
control
Monitoring and control of
Smartlink Acti 9
Indication and tripping
E-33
F
protections Electrical auxiliaries for iC60, iID, iSW-NA, RCA, ARA F-2
Electrical auxiliaries for C120, DPN Vigi, ID, C60H-DC devices F-9
Electrical auxiliaries for NG125 devices F-14
Remote control
RCA remote controls for iC60 circuit breakers F-18

G
Automatic reclosers
ARA automatic reclosers for iC60 and iID F-23
Electrical circuit control Electrical control
Reflex iC60 integrated control circuit breakers G-3
iMDU for Reflex iC60 G-9
iCT contactors G-10
iTL impulse relays G-26
TL+ impulse relays G-39
CT+ contactors G-41
Manual control
iPB pushbuttons
H
G-43
iSSW linear switches G-44
DIN rail selector switches iCMB, iCMD, iCME, iCMC, iCMV and iCMA G-45
Indication Indicators
iIL indicator lights H-2
SO bells and iRO buzzers
iTR transformers
H-3
H-4 I
Lighting, time and energy IC twilight switches I-2
management IHP, IH, IHH, ITM I-11
MIN timers I-24
STD and SCU range I-28
TH4, TH7 and THP1, THP2 I-33
Relays iRTA, iRTB, iRTC, iRTH, iRTL, iRTMF, iRBN, iRTBT,iRLI, iERL, iRCP, iRCI, I-42
iRCU, iRCC

Acti 9 | Catalogue 2014 5


Index

Reference Description Page Reference Description Page Reference Description Page


A9N21535 I_DPN 1P+N 6A B A-2 A9N21595 I_DPN N 3P+N 6A C A-3 A9K23332 iK60N 3P 32A B A-5
A9N21536 I_DPN 1P+N 10A B A-2 A9N21596 I_DPN N 3P+N 10A C A-3 A9K23340 iK60N 3P 40A B A-5
A9N21537 I_DPN 1P+N 16A B A-2 A9N21597 I_DPN N 3P+N 16A C A-3 A9K23350 iK60N 3P 50A B A-5
A9N21538 I_DPN 1P+N 20A B A-2 A9N21598 I_DPN N 3P+N 20A C A-3 A9K23363 iK60N 3P 63A B A-5
A9N21539 I_DPN 1P+N 25A B A-2 A9N21599 I_DPN N 3P+N 25A C A-3 A9K23406 iK60N 4P 6A B A-5
A9N21540 I_DPN 1P+N 32A B A-2 A9N21600 I_DPN N 3P+N 32A C A-3 A9K23410 iK60N 4P 10A B A-5
A9N21541 I_DPN 1P+N 40A B A-2 A9N21601 I_DPN N 3P+N 40A C A-3 A9K23416 iK60N 4P 16A B A-5
A9N21542 I_DPN 1P+N 1A C A-2 A9N21605 I_DPN N 3P+N 6A D A-3 A9K23420 iK60N 4P 20A B A-5
A9N21543 I_DPN 1P+N 2A C A-2 A9N21606 I_DPN N 3P+N 10A D A-3 A9K23425 iK60N 4P 25A B A-5
A9N21544 I_DPN 1P+N 3A C A-2 A9N21607 I_DPN N 3P+N 16A D A-3 A9K23432 iK60N 4P 32A B A-5
A9N21545 I_DPN 1P+N 6A C A-2 A9N21608 I_DPN N 3P+N 20A D A-3 A9K23440 iK60N 4P 40A B A-5
A9N21546 I_DPN 1P+N 10A C A-2 A9N21609 I_DPN N 3P+N 25A D A-3 A9K23450 iK60N 4P 50A B A-5
A9N21547 I_DPN 1P+N 16A C A-2 A9N21610 I_DPN N 3P+N 32A D A-3 A9K23463 iK60N 4P 63A B A-5
A9N21548 I_DPN 1P+N 20A C A-2 A9N21611 I_DPN N 3P+N 40A D A-3 A9K23601 iK60N 1P+N 1A B A-5
A9N21549 I_DPN 1P+N 25A C A-2 A9N21638 IDPN F 1P+N C 1A A-3 A9K23602 iK60N 1P+N 2A B A-5
A9N21550 I_DPN 1P+N 32A C A-2 A9N21641 IDPN F 1P+N C 2A A-3 A9K23603 iK60N 1P+N 3A B A-5
A9N21551 I_DPN 1P+N 40A C A-2 A9N21642 IDPN F 1P+N C 3A A-3 A9K23604 iK60N 1P+N 4A B A-5
A9N21723 13A B 1P+N A-2 A9N21643 IDPN F 1P+N C 6A A-3 A9K23606 iK60N 1P+N 6A B A-5
A9N21724 13A C 1P+N A-2 A9N21644 IDPN F 1P+N C 10A A-3 A9K23610 iK60N 1P+N 10A B A-5
A9N21731 13A B 3P+N A-2 A9N21645 IDPN F 1P+N C 16A A-3 A9K23616 iK60N 1P+N 16A B A-5
A9N21732 13A C 3P+N A-2 A9N21646 IDPN F 1P+N C 20A A-3 A9K23620 iK60N 1P+N 20A B A-5
A9N17515 IDPN N 1P+N B 4A A-3 A9N21647 IDPN F 1P+N C 25A A-3 A9K23625 iK60N 1P+N 25A B A-5
A9N17516 IDPN N 1P+N B 6A A-3 A9N21648 IDPN F 1P+N C 32A A-3 A9K23632 iK60N 1P+N 32A B A-5
A9N17517 IDPN N 1P+N B 10A A-3 A9N21649 IDPN F 1P+N C 40A A-3 A9K23640 iK60N 1P+N 40A B A-5
A9N17518 IDPN N 1P+N B 13A A-3 A9N21722 IDPN N 1P+N C 4A A-3 A9K23650 iK60N 1P+N 50A B A-5
A9N17519 IDPN N 1P+N B 16A A-3 A9N21725 IDPN N 1P+N C 13A A-3 A9K23663 iK60N 1P+N 63A B A-5
A9N17520 IDPN N 1P+N B 20A A-3 A9N21726 IDPN N 1P+N D 13A A-3 A9K24101 iK60N 1P 1A C A-7
A9N17521 IDPN N 1P+N B 25A A-3 A9N21727 IDPN N 3P C 13A A-3 A9K24102 iK60N 1P 2A C A-7
A9N17522 IDPN N 1P+N B 32A A-3 A9N21728 IDPN N 3P D 13A A-3 A9K24103 iK60N 1P 3A C A-7
A9N17523 IDPN N 1P+N B 40A A-3 A9N21729 IDPN N 3P+N C 13A A-3 A9K24104 iK60N 1P 4A C A-7
A9N17581 IDPN N 3P+N B 13A A-3 A9N21730 IDPN N 3P+N D 13A A-3 A9K24106 iK60N 1P 6A C A-7
A9N21552 I_DPN N 1P+N 1A C A-3 A9K23101 iK60N 1P 1A B A-5 A9K24110 iK60N 1P 10A C A-7
A9N21553 I_DPN N 1P+N 2A C A-3 A9K23102 iK60N 1P 2A B A-5 A9K24116 iK60N 1P 16A C A-7
A9N21554 I_DPN N 1P+N 3A C A-3 A9K23103 iK60N 1P 3A B A-5 A9K24120 iK60N 1P 20A C A-7
A9N21555 I_DPN N 1P+N 6A C A-3 A9K23104 iK60N 1P 4A B A-5 A9K24125 iK60N 1P 25A C A-7
A9N21556 I_DPN N 1P+N 10A C A-3 A9K23106 iK60N 1P 6A B A-5 A9K24132 iK60N 1P 32A C A-7
A9N21557 I_DPN N 1P+N 16A C A-3 A9K23110 iK60N 1P 10A B A-5 A9K24140 iK60N 1P 40A C A-7
A9N21558 I_DPN N 1P+N 20A C A-3 A9K23116 iK60N 1P 16A B A-5 A9K24150 iK60N 1P 50A C A-7
A9N21559 I_DPN N 1P+N 25A C A-3 A9K23120 iK60N 1P 20A B A-5 A9K24163 iK60N 1P 63A C A-7
A9N21560 I_DPN N 1P+N 32A C A-3 A9K23125 iK60N 1P 25A B A-5 A9K24201 iK60N 2P 1A C A-7
A9N21561 I_DPN N 1P+N 40A C A-3 A9K23132 iK60N 1P 32A B A-5 A9K24202 iK60N 2P 2A C A-7
A9N21565 I_DPN N 1P+N 6A D A-3 A9K23140 iK60N 1P 40A B A-5 A9K24203 iK60N 2P 3A C A-7
A9N21566 I_DPN N 1P+N 10A D A-3 A9K23150 iK60N 1P 50A B A-5 A9K24204 iK60N 2P 4A C A-7
A9N21567 I_DPN N 1P+N 16A D A-3 A9K23163 iK60N 1P 63A B A-5 A9K24206 iK60N 2P 6A C A-7
A9N21568 I_DPN N 1P+N 20A D A-3 A9K23201 iK60N 2P 1A B A-5 A9K24210 iK60N 2P 10A C A-7
A9N21569 I_DPN N 1P+N 25A D A-3 A9K23202 iK60N 2P 2A B A-5 A9K24216 iK60N 2P 16A C A-7
A9N21570 I_DPN N 1P+N 32A D A-3 A9K23203 iK60N 2P 3A B A-5 A9K24220 iK60N 2P 20A C A-7
A9N21571 I_DPN N 1P+N 40A D A-3 A9K23204 iK60N 2P 4A B A-5 A9K24225 iK60N 2P 25A C A-7
A9N21575 I_DPN N 3P 6A C A-3 A9K23206 iK60N 2P 6A B A-5 A9K24232 iK60N 2P 32A C A-7
A9N21576 I_DPN N 3P 10A C A-3 A9K23210 iK60N 2P 10A B A-5 A9K24240 iK60N 2P 40A C A-7
A9N21577 I_DPN N 3P 16A C A-3 A9K23216 iK60N 2P 16A B A-5 A9K24250 iK60N 2P 50A C A-7
A9N21578 I_DPN N 3P 20A C A-3 A9K23220 iK60N 2P 20A B A-5 A9K24263 iK60N 2P 63A C A-7
A9N21579 I_DPN N 3P 25A C A-3 A9K23225 iK60N 2P 25A B A-5 A9K24306 iK60N 3P 6A C A-7
A9N21580 I_DPN N 3P 32A C A-3 A9K23232 iK60N 2P 32A B A-5 A9K24310 iK60N 3P 10A C A-7
A9N21581 I_DPN N 3P 40A C A-3 A9K23240 iK60N 2P 40A B A-5 A9K24316 iK60N 3P 16A C A-7
A9N21585 I_DPN N 3P 6A D A-3 A9K23250 iK60N 2P 50A B A-5 A9K24320 iK60N 3P 20A C A-7
A9N21586 I_DPN N 3P 10A D A-3 A9K23263 iK60N 2P 63A B A-5 A9K24325 iK60N 3P 25A C A-7
A9N21587 I_DPN N 3P 16A D A-3 A9K23306 iK60N 3P 6A B A-5 A9K24332 iK60N 3P 32A C A-7
A9N21588 I_DPN N 3P 20A D A-3 A9K23310 iK60N 3P 10A B A-5 A9K24340 iK60N 3P 40A C A-7
A9N21589 I_DPN N 3P 25A D A-3 A9K23316 iK60N 3P 16A B A-5 A9K24350 iK60N 3P 50A C A-7
A9N21590 I_DPN N 3P 32A D A-3 A9K23320 iK60N 3P 20A B A-5 A9K24363 iK60N 3P 63A C A-7
A9N21591 I_DPN N 3P 40A D A-3 A9K23325 iK60N 3P 25A B A-5 A9K24406 iK60N 4P 6A C A-7

6 Acti 9 | Catalogue 2014


Index

Reference Description Page Reference Description Page Reference Description Page


A9K24410 iK60N 4P 10A C A-7 A9F44170 iC60N 1P 0.5A C A-9 A9F43410 iC60N 4P 10A B A-10
A9K24416 iK60N 4P 16A C A-7 A9F44201 iC60N 2P 1A C A-9 A9F43416 iC60N 4P 16A B A-10
A9K24420 iK60N 4P 20A C A-7 A9F44202 iC60N 2P 2A C A-9 A9F43420 iC60N 4P 20A B A-10
A9K24425 iK60N 4P 25A C A-7 A9F44203 iC60N 2P 3A C A-9 A9F43425 iC60N 4P 25A B A-10
A9K24432 iK60N 4P 32A C A-7 A9F44204 iC60N 2P 4A C A-9 A9F43432 iC60N 4P 32A B A-10
A9K24440 iK60N 4P 40A C A-7 A9F44206 iC60N 2P 6A C A-9 A9F43440 iC60N 4P 40A B A-10
A9K24450 iK60N 4P 50A C A-7 A9F44210 iC60N 2P 10A C A-9 A9F43450 iC60N 4P 50A B A-10
A9K24463 iK60N 4P 63A C A-7 A9F44216 iC60N 2P 16A C A-9 A9F43463 iC60N 4P 63A B A-10
A9K24601 iK60N 1P+N 1A C A-7 A9F44220 iC60N 2P 20A C A-9 A9F43470 IC60N 3P 0.5 A C A-10
A9K24602 iK60N 1P+N 2A C A-7 A9F44225 iC60N 2P 25A C A-9 A9F44301 iC60N 3P 1A C A-10
A9K24603 iK60N 1P+N 3A C A-7 A9F44232 iC60N 2P 32A C A-9 A9F44302 iC60N 3P 2A C A-10
A9K24604 iK60N 1P+N 4A C A-7 A9F44240 iC60N 2P 40A C A-9 A9F44303 IC60 N 3P 3 A C A-10
A9K24606 iK60N 1P+N 6A C A-7 A9F44250 iC60N 2P 50A C A-9 A9F44304 iC60N 3P 4A C A-10
A9K24610 iK60N 1P+N 10A C A-7 A9F44263 iC60N 2P 63A C A-9 A9F44306 iC60N 3P 6A C A-10
A9K24616 iK60N 1P+N 16A C A-7 A9F44270 iC60N 2P 0.5A C A-9 A9F44310 iC60N 3P 10A C A-10
A9K24620 iK60N 1P+N 20A C A-7 A9F45101 iC60N 1P 1A D A-9 A9F44316 iC60N 3P 16A C A-10
A9K24625 iK60N 1P+N 25A C A-7 A9F45102 iC60N 1P 2A D A-9 A9F44320 iC60N 3P 20A C A-10
A9K24632 iK60N 1P+N 32A C A-7 A9F45103 iC60N 1P 3A D A-9 A9F44325 iC60N 3P 25A C A-10
A9K24640 iK60N 1P+N 40A C A-7 A9F45104 iC60N 1P 4A D A-9 A9F44332 iC60N 3P 32A C A-10
A9K24650 iK60N 1P+N 50A C A-7 A9F45106 iC60N 1P 6A D A-9 A9F44340 iC60N 3P 40A C A-10
A9K24663 iK60N 1P+N 63A C A-7 A9F45110 iC60N 1P 10A D A-9 A9F44350 iC60N 3P 50A C A-10
A9F43101 iC60N 1P 1A B A-9 A9F45116 iC60N 1P 16A D A-9 A9F44363 iC60N 3P 63A C A-10
A9F43102 iC60N 1P 2A B A-9 A9F45120 iC60N 1P 20A D A-9 A9F44370 IC60N 4P 0.5 A C A-10
A9F43103 iC60N 1P 3A B A-9 A9F45125 iC60N 1P 25A D A-9 A9F44401 iC60N 4P 1A C A-10
A9F43104 iC60N 1P 4A B A-9 A9F45132 iC60N 1P 32A D A-9 A9F44402 iC60N 4P 2A C A-10
A9F43106 iC60N 1P 6A B A-9 A9F45140 iC60N 1P 40A D A-9 A9F44403 IC 60 N 4P 3A C A-10
A9F43110 iC60N 1P 10A B A-9 A9F45150 iC60N 1P 50A D A-9 A9F44404 iC60N 4P 4A C A-10
A9F43116 iC60N 1P 16A B A-9 A9F45163 iC60N 1P 63A D A-9 A9F44406 iC60N 4P 6A C A-10
A9F43120 iC60N 1P 20A B A-9 A9F45170 iC60N 1P 0.5A D A-9 A9F44410 iC60N 4P 10A C A-10
A9F43125 iC60N 1P 25A B A-9 A9F45201 iC60N 2P 1A D A-9 A9F44416 iC60N 4P 16A C A-10
A9F43132 iC60N 1P 32A B A-9 A9F45202 iC60N 2P 2A D A-9 A9F44420 iC60N 4P 20A C A-10
A9F43140 iC60N 1P 40A B A-9 A9F45203 iC60N 2P 3A D A-9 A9F44425 iC60N 4P 25A C A-10
A9F43150 iC60N 1P 50A B A-9 A9F45204 iC60N 2P 4A D A-9 A9F44432 iC60N 4P 32A C A-10
A9F43163 iC60N 1P 63A B A-9 A9F45206 iC60N 2P 6A D A-9 A9F44440 iC60N 4P 40A C A-10
A9F43170 iC60N 1P 0.5A B A-9 A9F45210 iC60N 2P 10A D A-9 A9F44450 iC60N 4P 50A C A-10
A9F43201 iC60N 2P 1A B A-9 A9F45216 iC60N 2P 16A D A-9 A9F44463 iC60N 4P 63A C A-10
A9F43202 iC60N 2P 2A B A-9 A9F45220 iC60N 2P 20A D A-9 A9F44470 IC60N 4P 0.5 A D A-10
A9F43203 iC60N 2P 3A B A-9 A9F45225 iC60N 2P 25A D A-9 A9F45301 iC60N 3P 1A D A-10
A9F43204 iC60N 2P 4A B A-9 A9F45232 iC60N 2P 32A D A-9 A9F45302 iC60N 3P 2A D A-10
A9F43206 iC60N 2P 6A B A-9 A9F45240 iC60N 2P 40A D A-9 A9F45303 IC 60 N 3P 3A D A-10
A9F43210 iC60N 2P 10A B A-9 A9F45250 iC60N 2P 50A D A-9 A9F45304 iC60N 3P 4A D A-10
A9F43216 iC60N 2P 16A B A-9 A9F45263 iC60N 2P 63A D A-9 A9F45306 iC60N 3P 6A D A-10
A9F43220 iC60N 2P 20A B A-9 A9F45270 iC60N 2P 0.5A D A-9 A9F45310 iC60N 3P 10A D A-10
A9F43225 iC60N 2P 25A B A-9 A9F43301 iC60N 3P 1A B A-10 A9F45316 iC60N 3P 16A D A-10
A9F43232 iC60N 2P 32A B A-9 A9F43302 iC60N 3P 2A B A-10 A9F45320 iC60N 3P 20A D A-10
A9F43240 iC60N 2P 40A B A-9 A9F43303 IC60N 3P 3P 3A B A-10 A9F45325 iC60N 3P 25A D A-10
A9F43250 iC60N 2P 50A B A-9 A9F43304 iC60N 3P 4A B A-10 A9F45332 iC60N 3P 32A D A-10
A9F43263 iC60N 2P 63A B A-9 A9F43306 iC60N 3P 6A B A-10 A9F45340 iC60N 3P 40A D A-10
A9F43270 iC60N 2P 0.5A B A-9 A9F43310 iC60N 3P 10A B A-10 A9F45350 iC60N 3P 50A D A-10
A9F44101 iC60N 1P 1A C A-9 A9F43316 iC60N 3P 16A B A-10 A9F45363 iC60N 3P 63A D A-10
A9F44102 iC60N 1P 2A C A-9 A9F43320 iC60N 3P 20A B A-10 A9F45370 IC 60N 3P 0.5 A D A-10
A9F44103 iC60N 1P 3A C A-9 A9F43325 iC60N 3P 25A B A-10 A9F45401 iC60N 4P 1A D A-10
A9F44104 iC60N 1P 4A C A-9 A9F43332 iC60N 3P 32A B A-10 A9F45402 iC60N 4P 2A D A-10
A9F44106 iC60N 1P 6A C A-9 A9F43340 iC60N 3P 40A B A-10 A9F45403 IC60N 4P 3A D A-10
A9F44110 iC60N 1P 10A C A-9 A9F43350 iC60N 3P 50A B A-10 A9F45404 iC60N 4P 4A D A-10
A9F44116 iC60N 1P 16A C A-9 A9F43363 iC60N 3P 63A B A-10 A9F45406 iC60N 4P 6A D A-10
A9F44120 iC60N 1P 20A C A-9 A9F43370 IC60N 4P 0.5 A B A-10 A9F45410 iC60N 4P 10A D A-10
A9F44125 iC60N 1P 25A C A-9 A9F43401 iC60N 4P 1A B A-10 A9F45416 iC60N 4P 16A D A-10
A9F44132 iC60N 1P 32A C A-9 A9F43402 iC60N 4P 2A B A-10 A9F45420 iC60N 4P 20A D A-12
A9F44140 iC60N 1P 40A C A-9 A9F43403 IC60N 4P 3A B A-10 A9F45425 iC60N 4P 25A D A-12
A9F44150 iC60N 1P 50A C A-9 A9F43404 iC60N 4P 4A B A-10 A9F45432 iC60N 4P 32A D A-12
A9F44163 iC60N 1P 63A C A-9 A9F43406 iC60N 4P 6A B A-10 A9F45440 iC60N 4P 40A D A-12

Acti 9 | Catalogue 2014 7


Index

Reference Description Page Reference Description Page Reference Description Page


A9F45450 iC60N 4P 50A D A-12 A9F55150 iC60H 1P 50A D A-12 A9F55301 iC60H 3P 1A D A-13
A9F45463 iC60N 4P 63A D A-12 A9F55163 iC60H 1P 63A D A-12 A9F55302 iC60H 3P 2A D A-13
A9F45470 IC60N 4P 0.5 A B A-12 A9F55201 iC60H 2P 1A D A-12 A9F55304 iC60H 3P 4A D A-13
A9F53101 iC60H 1P 1A B A-12 A9F55202 iC60H 2P 2A D A-12 A9F55306 iC60H 3P 6A D A-13
A9F53102 iC60H 1P 2A B A-12 A9F55204 iC60H 2P 4A D A-12 A9F55310 iC60H 3P 10A D A-13
A9F53103 IC60H 1P 3A B A-12 A9F55206 iC60H 2P 6A D A-12 A9F55316 iC60H 3P 16A D A-13
A9F53104 iC60H 1P 4A B A-12 A9F55210 iC60H 2P 10A D A-12 A9F55320 iC60H 3P 20A D A-13
A9F53106 iC60H 1P 6A B A-12 A9F55216 iC60H 2P 16A D A-12 A9F55325 iC60H 3P 25A D A-13
A9F53110 iC60H 1P 10A B A-12 A9F55220 iC60H 2P 20A D A-12 A9F55332 iC60H 3P 32A D A-13
A9F53116 iC60H 1P 16A B A-12 A9F55225 iC60H 2P 25A D A-12 A9F55340 iC60H 3P 40A D A-13
A9F53120 iC60H 1P 20A B A-12 A9F55232 iC60H 2P 32A D A-12 A9F55350 iC60H 3P 50A D A-13
A9F53125 iC60H 1P 25A B A-12 A9F55240 iC60H 2P 40A D A-12 A9F55363 iC60H 3P 63A D A-13
A9F53132 iC60H 1P 32A B A-12 A9F55250 iC60H 2P 50A D A-12 A9F55401 iC60H 4P 1A D A-13
A9F53140 iC60H 1P 40A B A-12 A9F55263 iC60H 2P 63A D A-12 A9F55402 iC60H 4P 2A D A-13
A9F53150 iC60H 1P 50A B A-12 A9F53301 iC60H 3P 1A B A-13 A9F55404 iC60H 4P 4A D A-13
A9F53163 iC60H 1P 63A B A-12 A9F53302 iC60H 3P 2A B A-13 A9F55406 iC60H 4P 6A D A-13
A9F53201 iC60H 2P 1A B A-12 A9F53304 iC60H 3P 4A B A-13 A9F55410 iC60H 4P 10A D A-13
A9F53202 iC60H 2P 2A B A-12 A9F53306 iC60H 3P 6A B A-13 A9F55416 iC60H 4P 16A D A-13
A9F53204 iC60H 2P 4A B A-12 A9F53310 iC60H 3P 10A B A-13 A9F55420 iC60H 4P 20A D A-13
A9F53206 iC60H 2P 6A B A-12 A9F53316 iC60H 3P 16A B A-13 A9F55425 iC60H 4P 25A D A-13
A9F53210 iC60H 2P 10A B A-12 A9F53320 iC60H 3P 20A B A-13 A9F55432 iC60H 4P 32A D A-13
A9F53216 iC60H 2P 16A B A-12 A9F53325 iC60H 3P 25A B A-13 A9F55440 iC60H 4P 40A D A-13
A9F53220 iC60H 2P 20A B A-12 A9F53332 iC60H 3P 32A B A-13 A9F55450 iC60H 4P 50A D A-13
A9F53225 iC60H 2P 25A B A-12 A9F53340 iC60H 3P 40A B A-13 A9F55463 iC60H 4P 63A D A-13
A9F53232 iC60H 2P 32A B A-12 A9F53350 iC60H 3P 50A B A-13 A9F93101 iC60L 1P 1A B A-16
A9F53240 iC60H 2P 40A B A-12 A9F53363 iC60H 3P 63A B A-13 A9F93102 iC60L 1P 2A B A-16
A9F53250 iC60H 2P 50A B A-12 A9F53401 iC60H 4P 1A B A-13 A9F93103 IC60L 1P 3A B A-16
A9F53263 iC60H 2P 63A B A-12 A9F53402 iC60H 4P 2A B A-13 A9F93104 iC60L 1P 4A B A-16
A9F54101 iC60H 1P 1A C A-12 A9F53404 iC60H 4P 4A B A-13 A9F93106 iC60L 1P 6A B A-16
A9F54102 iC60H 1P 2A C A-12 A9F53406 iC60H 4P 6A B A-13 A9F93110 iC60L 1P 10A B A-16
A9F54104 iC60H 1P 4A C A-12 A9F53410 iC60H 4P 10A B A-13 A9F93116 iC60L 1P 16A B A-16
A9F54106 iC60H 1P 6A C A-12 A9F53416 iC60H 4P 16A B A-13 A9F93120 iC60L 1P 20A B A-16
A9F54110 iC60H 1P 10A C A-12 A9F53420 iC60H 4P 20A B A-13 A9F93125 iC60L 1P 25A B A-16
A9F54116 iC60H 1P 16A C A-12 A9F53425 iC60H 4P 25A B A-13 A9F93132 iC60L 1P 32A B A-16
A9F54120 iC60H 1P 20A C A-12 A9F53432 iC60H 4P 32A B A-13 A9F93140 iC60L 1P 40A B A-16
A9F54125 iC60H 1P 25A C A-12 A9F53440 iC60H 4P 40A B A-13 A9F93150 iC60L 1P 50A B A-16
A9F54132 iC60H 1P 32A C A-12 A9F53450 iC60H 4P 50A B A-13 A9F93163 iC60L 1P 63A B A-16
A9F54140 iC60H 1P 40A C A-12 A9F53463 iC60H 4P 63A B A-13 A9F93170 iC60L 1P 0,5A B A-16
A9F54150 iC60H 1P 50A C A-12 A9F54301 iC60H 3P 1A C A-13 A9F93201 iC60L 2P 1A B A-16
A9F54163 iC60H 1P 63A C A-12 A9F54302 iC60H 3P 2A C A-13 A9F93202 iC60L 2P 2A B A-16
A9F54201 iC60H 2P 1A C A-12 A9F54304 iC60H 3P 4A C A-13 A9F93203 IC60L 2P 3A B A-16
A9F54202 iC60H 2P 2A C A-12 A9F54306 iC60H 3P 6A C A-13 A9F93204 iC60L 2P 4A B A-16
A9F54204 iC60H 2P 4A C A-12 A9F54310 iC60H 3P 10A C A-13 A9F93206 iC60L 2P 6A B A-16
A9F54206 iC60H 2P 6A C A-12 A9F54316 iC60H 3P 16A C A-13 A9F93210 iC60L 2P 10A B A-16
A9F54210 iC60H 2P 10A C A-12 A9F54320 iC60H 3P 20A C A-13 A9F93216 iC60L 2P 16A B A-16
A9F54216 iC60H 2P 16A C A-12 A9F54325 iC60H 3P 25A C A-13 A9F93220 iC60L 2P 20A B A-16
A9F54220 iC60H 2P 20A C A-12 A9F54332 iC60H 3P 32A C A-13 A9F93225 iC60L 2P 25A B A-16
A9F54225 iC60H 2P 25A C A-12 A9F54340 iC60H 3P 40A C A-13 A9F93232 iC60L 2P 32A B A-16
A9F54232 iC60H 2P 32A C A-12 A9F54350 iC60H 3P 50A C A-13 A9F93240 iC60L 2P 40A B A-16
A9F54240 iC60H 2P 40A C A-12 A9F54363 iC60H 3P 63A C A-13 A9F93250 iC60L 2P 50A B A-16
A9F54250 iC60H 2P 50A C A-12 A9F54401 iC60H 4P 1A C A-13 A9F93263 iC60L 2P 63A B A-16
A9F54263 iC60H 2P 63A C A-12 A9F54402 iC60H 4P 2A C A-13 A9F93270 IC60L 2P 0.5A C A-16
A9F55101 iC60H 1P 1A D A-12 A9F54404 iC60H 4P 4A C A-13 A9F94101 iC60L 1P 1A C A-16
A9F55102 iC60H 1P 2A D A-12 A9F54406 iC60H 4P 6A C A-13 A9F94102 iC60L 1P 2A C A-16
A9F55104 iC60H 1P 4A D A-12 A9F54410 iC60H 4P 10A C A-13 A9F94103 IC60L 1P 3A C A-16
A9F55106 iC60H 1P 6A D A-12 A9F54416 iC60H 4P 16A C A-13 A9F94104 iC60L 1P 4A C A-16
A9F55110 iC60H 1P 10A D A-12 A9F54420 iC60H 4P 20A C A-13 A9F94106 iC60L 1P 6A C A-16
A9F55116 iC60H 1P 16A D A-12 A9F54425 iC60H 4P 25A C A-13 A9F94110 iC60L 1P 10A C A-16
A9F55120 iC60H 1P 20A D A-12 A9F54432 iC60H 4P 32A C A-13 A9F94116 iC60L 1P 16A C A-16
A9F55125 iC60H 1P 25A D A-12 A9F54440 iC60H 4P 40A C A-13 A9F94120 iC60L 1P 20A C A-16
A9F55132 iC60H 1P 32A D A-12 A9F54450 iC60H 4P 50A C A-13 A9F94125 iC60L 1P 25A C A-16
A9F55140 iC60H 1P 40A D A-12 A9F54463 iC60H 4P 63A C A-13 A9F94132 iC60L 1P 32A C A-16

8 Acti 9 | Catalogue 2014


Index

Reference Description Page Reference Description Page Reference Description Page


A9F94140 iC60L 1P 40A C A-16 A9F92172 iC60L 1P 1,6A Z A-16 A9F94406 iC60L 4P 6A C A-17
A9F94150 iC60L 1P 50A C A-16 A9F92201 iC60L 2P 1A Z A-16 A9F94410 iC60L 4P 10A C A-17
A9F94163 iC60L 1P 63A C A-16 A9F92202 iC60L 2P 2A Z A-16 A9F94416 iC60L 4P 16A C A-17
A9F94170 IC60L 1P 0.5A C A-16 A9F92203 iC60L 2P 3A Z A-16 A9F94420 iC60L 4P 20A C A-17
A9F94201 iC60L 2P 1A C A-16 A9F92204 iC60L 2P 4A Z A-16 A9F94425 iC60L 4P 25A C A-17
A9F94202 iC60L 2P 2A C A-16 A9F92206 iC60L 2P 6A Z A-16 A9F94432 iC60L 4P 32A C A-17
A9F94203 IC60L 3P 3A C A-16 A9F92210 iC60L 2P 10A Z A-16 A9F94440 iC60L 4P 40A C A-17
A9F94204 iC60L 2P 4A C A-16 A9F92216 iC60L 2P 16A Z A-16 A9F94450 iC60L 4P 50A C A-17
A9F94206 iC60L 2P 6A C A-16 A9F92220 iC60L 2P 20A Z A-16 A9F94463 iC60L 4P 63A C A-17
A9F94210 iC60L 2P 10A C A-16 A9F92225 iC60L 2P 25A Z A-16 A9F94470 IC60L 4P 0.5A C A-17
A9F94216 iC60L 2P 16A C A-16 A9F92232 iC60L 2P 32A Z A-16 A9F95301 iC60L 3P 1A K A-17
A9F94220 iC60L 2P 20A C A-16 A9F92240 iC60L 2P 40A Z A-16 A9F95302 iC60L 3P 2A K A-17
A9F94225 iC60L 2P 25A C A-16 A9F92250 iC60L 2P 50A Z A-16 A9F95303 IC60L 3P 3A K A-17
A9F94232 iC60L 2P 32A C A-16 A9F92263 iC60L 2P 63A Z A-16 A9F95304 iC60L 3P 4A K A-17
A9F94240 iC60L 2P 40A C A-16 A9F92270 IC60L 2P 0.5A Z A-16 A9F95306 iC60L 3P 6A K A-17
A9F94250 iC60L 2P 50A C A-16 A9F92272 iC60L 2P 1,6A Z A-16 A9F95310 iC60L 3P 10A K A-17
A9F94263 iC60L 2P 63A C A-16 A9F93301 iC60L 3P 1A B A-17 A9F95316 iC60L 3P 16A K A-17
A9F94270 IC60L 2P 0.5 A K A-16 A9F93302 iC60L 3P 2A B A-17 A9F95320 iC60L 3P 20A K A-17
A9F95101 iC60L 1P 1A K A-16 A9F93303 IC60L 3P 3A B A-17 A9F95325 iC60L 3P 25A K A-17
A9F95102 iC60L 1P 2A K A-16 A9F93304 iC60L 3P 4A B A-17 A9F95332 iC60L 3P 32A K A-17
A9F95103 iC60L 1P 3A K A-16 A9F93306 iC60L 3P 6A B A-17 A9F95340 iC60L 3P 40A K A-17
A9F95104 iC60L 1P 4A K A-16 A9F93310 iC60L 3P 10A B A-17 A9F95350 iC60L 3P 50A K A-17
A9F95106 iC60L 1P 6A K A-16 A9F93316 iC60L 3P 16A B A-17 A9F95363 iC60L 3P 63A K A-17
A9F95110 iC60L 1P 10A K A-16 A9F93320 iC60L 3P 20A B A-17 A9F95370 IC60L 3P 0.5A K A-17
A9F95116 iC60L 1P 16A K A-16 A9F93325 iC60L 3P 25A B A-17 A9F95372 iC60L 3P 1,6A K A-17
A9F95120 iC60L 1P 20A K A-16 A9F93332 iC60L 3P 32A B A-17 A9F95401 iC60L 4P 1A K A-17
A9F95125 iC60L 1P 25A K A-16 A9F93340 iC60L 3P 40A B A-17 A9F95402 iC60L 4P 2A K A-17
A9F95132 iC60L 1P 32A K A-16 A9F93350 iC60L 3P 50A B A-17 A9F95403 IC60L 4P 3A K A-17
A9F95140 iC60L 1P 40A K A-16 A9F93363 iC60L 3P 63A B A-17 A9F95404 iC60L 4P 4A K A-17
A9F95150 iC60L 1P 50A K A-16 A9F93370 IC60L 3P 0.5 A B A-17 A9F95406 iC60L 4P 6A K A-17
A9F95163 iC60L 1P 63A K A-16 A9F93401 iC60L 4P 1A B A-17 A9F95410 iC60L 4P 10A K A-17
A9F95170 IC60L 1P 0.5A K A-16 A9F93402 iC60L 4P 2A B A-17 A9F95416 iC60L 4P 16A K A-17
A9F95172 iC60L 1P 1,6A K A-16 A9F93403 IC60L 4P 3A B A-17 A9F95420 iC60L 4P 20A K A-17
A9F95201 iC60L 2P 1A K A-16 A9F93404 iC60L 4P 4A B A-17 A9F95425 iC60L 4P 25A K A-17
A9F95202 iC60L 2P 2A K A-16 A9F93406 iC60L 4P 6A B A-17 A9F95432 iC60L 4P 32A K A-17
A9F95203 IC60L 2P 3A K A-16 A9F93410 iC60L 4P 10A B A-17 A9F95440 iC60L 4P 40A K A-17
A9F95204 iC60L 2P 4A K A-16 A9F93416 iC60L 4P 16A B A-17 A9F95450 iC60L 4P 50A K A-17
A9F95206 iC60L 2P 6A K A-16 A9F93420 iC60L 4P 20A B A-17 A9F95463 iC60L 4P 63A K A-17
A9F95210 iC60L 2P 10A K A-16 A9F93425 iC60L 4P 25A B A-17 A9F95470 IC60L 4P 0.5A K A-17
A9F95216 iC60L 2P 16A K A-16 A9F93432 iC60L 4P 32A B A-17 A9F95472 iC60L 4P 1,6A K A-17
A9F95220 iC60L 2P 20A K A-16 A9F93440 iC60L 4P 40A B A-17 A9F92301 IC60L 3P 1A Z A-17
A9F95225 iC60L 2P 25A K A-16 A9F93450 iC60L 4P 50A B A-17 A9F92302 iC60L 3P 2A Z A-17
A9F95232 iC60L 2P 32A K A-16 A9F93463 iC60L 4P 63A B A-17 A9F92303 iC60L 3P 3A Z A-17
A9F95240 iC60L 2P 40A K A-16 A9F93470 IC60L 4P 0.5A B A-17 A9F92304 iC60L 3P 4A Z A-17
A9F95250 iC60L 2P 50A K A-16 A9F94301 iC60L 3P 1A C A-17 A9F92306 iC60L 3P 6A Z A-17
A9F95263 iC60L 2P 63A K A-16 A9F94302 iC60L 3P 2A C A-17 A9F92310 iC60L 3P 10A Z A-17
A9F95270 IC60L 2P 0.5 A K A-16 A9F94303 IC60L 3P 3A C A-17 A9F92316 iC60L 3P 16A Z A-17
A9F95272 iC60L 2P 1,6A K A-16 A9F94304 iC60L 3P 4A C A-17 A9F92320 iC60L 3P 20A Z A-17
A9F92101 iC60L 1P 1A Z A-16 A9F94306 iC60L 3P 6A C A-17 A9F92325 iC60L 3P 25A Z A-17
A9F92102 iC60L 1P 2A Z A-16 A9F94310 iC60L 3P 10A C A-17 A9F92332 iC60L 3P 32A Z A-17
A9F92103 iC60L 1P 3A Z A-16 A9F94316 iC60L 3P 16A C A-17 A9F92340 iC60L 3P 40A Z A-17
A9F92104 iC60L 1P 4A Z A-16 A9F94320 iC60L 3P 20A C A-17 A9F92350 iC60L 3P 50A Z A-17
A9F92106 iC60L 1P 6A Z A-16 A9F94325 iC60L 3P 25A C A-17 A9F92363 iC60L 3P 63A Z A-17
A9F92110 iC60L 1P 10A Z A-16 A9F94332 iC60L 3P 32A C A-17 A9F92370 iC60L 3P 0.5A Z A-17
A9F92116 iC60L 1P 16A Z A-16 A9F94340 iC60L 3P 40A C A-17 A9F92372 iC60L 3P 1,6A Z A-17
A9F92120 iC60L 1P 20A Z A-16 A9F94350 iC60L 3P 50A C A-17 A9F92401 iC60L 4P 1A Z A-17
A9F92125 iC60L 1P 25A Z A-16 A9F94363 iC60L 3P 63A C A-17 A9F92402 iC60L 4P 2A Z A-17
A9F92132 iC60L 1P 32A Z A-16 A9F94370 IC60L 0.5A 3P C A-17 A9F92403 iC60L 4P 3A Z A-17
A9F92140 iC60L 1P 40A Z A-16 A9F94401 iC60L 4P 1A C A-17 A9F92404 iC60L 4P 4A Z A-17
A9F92150 iC60L 1P 50A Z A-16 A9F94402 iC60L 4P 2A C A-17 A9F92406 iC60L 4P 6A Z A-17
A9F92163 iC60L 1P 63A Z A-16 A9F94403 IC60L 4P 3A C A-17 A9F92410 iC60L 4P 10A Z A-17
A9F92170 IC60L 1P 0.5A Z A-16 A9F94404 iC60L 4P 4A C A-17 A9F92416 iC60L 4P 16A Z A-17

Acti 9 | Catalogue 2014 9


Index

Reference Description Page Reference Description Page Reference Description Page


A9F92420 iC60L 4P 20A Z A-17 A9N18404 C120H 1P 125A B A-23 18623 NG125N 2P 20A C A-29
A9F92425 iC60L 4P 25A Z A-17 A9N18412 C120H 2P 63A B A-23 18624 NG125N 2P 25A C A-29
A9F92432 iC60L 4P 32A Z A-17 A9N18413 C120H 2P 80A B A-23 18625 NG125N 2P 32A C A-29
A9F92440 iC60L 4P 40A Z A-17 A9N18414 C120H 2P 100A B A-23 18626 NG125N 2P 40A C A-29
A9F92450 iC60L 4P 50A Z A-17 A9N18415 C120H 2P 125A B A-23 18627 NG125N 2P 50A C A-29
A9F92463 iC60L 4P 63A Z A-17 A9N18445 C120H 1P 63A C A-23 18628 NG125N 2P 63A C A-29
A9F92470 IC60L 4P 0.5A Z A-17 A9N18446 C120H 1P 80A C A-23 18629 NG125N 2P 80A C A-29
A9F92472 iC60L 4P 1,6A Z A-17 A9N18447 C120H 1P 100A C A-23 18632 NG125N 3P 10A C A-29
A9N18340 C120N 1P 63A B A-20 A9N18448 C120H 1P 125A C A-23 18633 NG125N 3P 16A C A-29
A9N18341 C120N 1P 80A B A-20 A9N18456 C120H 2P 63A C A-23 18634 NG125N 3P 20A C A-29
A9N18342 C120N 1P 100A B A-20 A9N18457 C120H 2P 80A C A-23 18635 NG125N 3P 25A C A-29
A9N18343 C120N 1P 125A B A-20 A9N18458 C120H 2P 100A C A-23 18636 NG125N 3P 32A C A-29
A9N18344 C120N 2P 63A B A-20 A9N18459 C120H 2P 125A C A-23 18637 NG125N 3P 40A C A-29
A9N18345 C120N 2P 80A B A-20 A9N18489 C120H 1P 63A D A-23 18638 NG125N 3P 50A C A-29
A9N18346 C120N 2P 100A B A-20 A9N18490 C120H 1P 80A D A-23 18639 NG125N 3P 63A C A-29
A9N18347 C120N 2P 125A B A-20 A9N18491 C120H 1P 100A D A-23 18640 NG125N 3P 80A C A-29
A9N18356 C120N 1P 63A C A-20 A9N18492 C120H 1P 125A D A-23 18642 NG125N 3P 100A C A-29
A9N18357 C120N 1P 80A C A-20 A9N18500 C120H 2P 63A D A-23 18644 NG125N 3P 125A C A-29
A9N18358 C120N 1P 100A C A-20 A9N18501 C120H 2P 80A D A-23 18646 NG125N 3P AND N 80A C A-29
A9N18359 C120N 1P 125A C A-20 A9N18502 C120H 2P 100A D A-23 18647 NG125N 3P AND N 100A C A-29
A9N18360 C120N 2P 63A C A-20 A9N18503 C120H 2P 125A D A-23 18648 NG125N 3P AND N 125A C A-29
A9N18361 C120N 2P 80A C A-20 A9N18423 C120H 3P 63A B A-24 18649 NG125N 4P 10A C A-29
A9N18362 C120N 2P 100A C A-20 A9N18424 C120H 3P 80A B A-24 18650 NG125N 4P 16A C A-29
A9N18363 C120N 2P 125A C A-20 A9N18425 C120H 3P 100A B A-24 18651 NG125N 4P 20A C A-29
A9N18378 C120N 1P 63A D A-20 A9N18426 C120H 3P 125A B A-24 18652 NG125N 4P 25A C A-29
A9N18379 C120N 1P 80A D A-20 A9N18434 C120H 4P 63A B A-24 18653 NG125N 4P 32A C A-29
A9N18380 C120N 1P 100A D A-20 A9N18435 C120H 4P 80A B A-24 18654 NG125N 4P 40A C A-29
A9N18381 C120N 1P 125A D A-20 A9N18436 C120H 4P 100A B A-24 18655 NG125N 4P 50A C A-29
A9N18382 C120N 2P 63A D A-20 A9N18437 C120H 4P 125A B A-24 18656 NG125N 4P 63A C A-29
A9N18383 C120N 2P 80A D A-20 A9N18467 C120H 3P 63A C A-24 18658 NG125N 4P 80A C A-29
A9N18384 C120N 2P 100A D A-20 A9N18468 C120H 3P 80A C A-24 18660 NG125N 4P 100A C A-29
A9N18385 C120N 2P 125A D A-20 A9N18469 C120H 3P 100A C A-24 18662 NG125N 4P 125A C A-29
A9N18348 C120N 3P 63A B A-21 A9N18470 C120H 3P 125A C A-24 18663 NG125N 3P 80A B A-29
A9N18349 C120N 3P 80A B A-21 A9N18478 C120H 4P 63A C A-24 18664 NG125N 3P 100A B A-29
A9N18350 C120N 3P 100A B A-21 A9N18479 C120H 4P 80A C A-24 18665 NG125N 3P 125A B A-29
A9N18351 C120N 3P 125A B A-21 A9N18480 C120H 4P 100A C A-24 18666 NG125N 4P 80A B A-29
A9N18352 C120N 4P 63A B A-21 A9N18481 C120H 4P 125A C A-24 18667 NG125N 4P 100A B A-29
A9N18353 C120N 4P 80A B A-21 A9N18511 C120H 3P 63A D A-24 18668 NG125N 4P 125A B A-29
A9N18354 C120N 4P 100A B A-21 A9N18512 C120H 3P 80A D A-24 18669 NG125N 3P 80A D A-29
A9N18355 C120N 4P 125A B A-21 A9N18513 C120H 3P 100A D A-24 18670 NG125N 3P 100A D A-29
A9N18364 C120N 3P 63A C A-21 A9N18514 C120H 3P 125A D A-24 18671 NG125N 3P 125A D A-29
A9N18365 C120N 3P 80A C A-21 A9N18522 C120H 4P 63A D A-24 18672 NG125N 4P 80A D A-29
A9N18367 C120N 3P 100A C A-21 A9N18523 C120H 4P 80A D A-24 18673 NG125N 4P 100A D A-29
A9N18369 C120N 3P 125A C A-21 A9N18524 C120H 4P 100A D A-24 18674 NG125N 4P 125A D A-29
A9N18371 C120N 4P 63A C A-21 A9N18525 C120H 4P 125A D A-24 18705 NG125H 1P 10A C A-31
A9N18372 C120N 4P 80A C A-21 18603 NG125Na 3P 80A C A-27 18706 NG125H 1P 16A C A-31
A9N18373 C120N 4P 80A C A-21 18604 NG125Na 3P 100A C A-27 18707 NG125H 1P 20A C A-31
A9N18374 C120N 4P 100A C A-21 18605 NG125Na 3P 125A C A-27 18708 NG125H 1P 25A C A-31
A9N18375 C120N 4P 100A C A-21 18607 NG125Na 4P 80A C A-27 18709 NG125H 1P 32A C A-31
A9N18376 C120N 4P 125A C A-21 18608 NG125Na 4P 100A C A-27 18710 NG125H 1P 40A C A-31
A9N18377 C120N 4P 125A C A-21 18609 NG125Na 4P 125A C A-27 18711 NG125H 1P 50A C A-31
A9N18386 C120N 3P 63A D A-21 18610 NG125N 1P 10A C A-29 18712 NG125H 1P 63A C A-31
A9N18387 C120N 3P 80A D A-21 18611 NG125N 1P 16A C A-29 18713 NG125H 1P 80A C A-31
A9N18388 C120N 3P 100A D A-21 18612 NG125N 1P 20A C A-29 18714 NG125H 2P 10A C A-31
A9N18389 C120N 3P 125A D A-21 18613 NG125N 1P 25A C A-29 18715 NG125H 2P 16A C A-31
A9N18390 C120N 4P 63A D A-21 18614 NG125N 1P 32A C A-29 18716 NG125H 2P 20A C A-31
A9N18391 C120N 4P 80A D A-21 18615 NG125N 1P 40A C A-29 18717 NG125H 2P 25A C A-31
A9N18392 C120N 4P 100A D A-21 18616 NG125N 1P 50A C A-29 18718 NG125H 2P 32A C A-31
A9N18393 C120N 4P 125A D A-21 18617 NG125N 1P 63A C A-29 18719 NG125H 2P 40A C A-31
A9N18401 C120H 1P 63A B A-23 18618 NG125N 1P 80A C A-29 18720 NG125H 2P 50A C A-31
A9N18402 C120H 1P 80A B A-23 18621 NG125N 2P 10A C A-29 18721 NG125H 2P 63A C A-31
A9N18403 C120H 1P 100A B A-23 18622 NG125N 2P 16A C A-29 18722 NG125H 2P 80A C A-31

10 Acti 9 | Catalogue 2014


Index

Reference Description Page Reference Description Page Reference Description Page


18723 NG125H 3P 10A C A-31 18785 NG125L 1P 80A C A-33 18864 NG125L 4P 63A D A-33
18724 NG125H 3P 16A C A-31 18788 NG125L 2P 10A C A-33 18865 NG125L 4P 80A D A-33
18725 NG125H 3P 20A C A-31 18789 NG125L 2P 16A C A-33 A9N61500 C60H-DC 1P 0,5A C 250Vdc A-35
18726 NG125H 3P 25A C A-31 18790 NG125L 2P 20A C A-33 A9N61501 C60H-DC 1P 1A C 250Vdc A-35
18727 NG125H 3P 32A C A-31 18791 NG125L 2P 25A C A-33 A9N61502 C60H-DC 1P 2A C 250Vdc A-35
18728 NG125H 3P 40A C A-31 18792 NG125L 2P 32A C A-33 A9N61503 C60H-DC 1P 3A C 250Vdc A-35
18729 NG125H 3P 50A C A-31 18793 NG125L 2P 40A C A-33 A9N61504 C60H-DC 1P 4A C 250Vdc A-35
18730 NG125H 3P 63A C A-31 18794 NG125L 2P 50A C A-33 A9N61505 C60H-DC 1P 5A C 250Vdc A-35
18731 NG125H 3P 80A C A-31 18795 NG125L 2P 63A C A-33 A9N61506 C60H-DC 1P 6A C 250Vdc A-35
18732 NG125H 4P 10A C A-31 18796 NG125L 2P 80A C A-33 A9N61508 C60H-DC 1P 10A C 250Vdc A-35
18733 NG125H 4P 16A C A-31 18799 NG125L 3P 10A C A-33 A9N61509 C60H-DC 1P 13A C 250Vdc A-35
18734 NG125H 4P 20A C A-31 18800 NG125L 3P 16A C A-33 A9N61510 C60H-DC 1P 15A C 250Vdc A-35
18735 NG125H 4P 25A C A-31 18801 NG125L 3P 20A C A-33 A9N61511 C60H-DC 1P 16A C 250Vdc A-35
18736 NG125H 4P 32A C A-31 18802 NG125L 3P 25A C A-33 A9N61512 C60H-DC 1P 20A C 250Vdc A-35
18737 NG125H 4P 40A C A-31 18803 NG125L 3P 32A C A-33 A9N61513 C60H-DC 1P 25A C 250Vdc A-35
18738 NG125H 4P 50A C A-31 18804 NG125L 3P 40A C A-33 A9N61514 C60H-DC 1P 30A C 250Vdc A-35
18739 NG125H 4P 63A C A-31 18805 NG125L 3P 50A C A-33 A9N61515 C60H-DC 1P 32A C 250Vdc A-35
18740 NG125H 4P 80A C A-31 18806 NG125L 3P 63A C A-33 A9N61517 C60H-DC 1P 40A C 250Vdc A-35
18741 NG125L 1P 10A B A-33 18807 NG125L 3P 80A C A-33 A9N61518 C60H-DC 1P 50A C 250Vdc A-35
18742 NG125L 1P 16A B A-33 18821 NG125L 4P 10A C A-33 A9N61519 C60H-DC 1P 63A C 250Vdc A-35
18743 NG125L 1P 20A B A-33 18822 NG125L 4P 16A C A-33 A9N61520 C60H-DC 2P 0,5A C 500Vdc A-35
18744 NG125L 1P 25A B A-33 18823 NG125L 4P 20A C A-33 A9N61521 C60H-DC 2P 1A C 500Vdc A-35
18745 NG125L 1P 32A B A-33 18824 NG125L 4P 25A C A-33 A9N61522 C60H-DC 2P 2A C 500Vdc A-35
18746 NG125L 1P 40A B A-33 18825 NG125L 4P 32A C A-33 A9N61523 C60H-DC 2P 3A C 500Vdc A-35
18747 NG125L 1P 50A B A-33 18826 NG125L 4P 40A C A-33 A9N61524 C60H-DC 2P 4A C 500Vdc A-35
18748 NG125L 1P 63A B A-33 18827 NG125L 4P 50A C A-33 A9N61525 C60H-DC 2P 5A C 500Vdc A-35
18749 NG125L 1P 80A B A-33 18828 NG125L 4P 63A C A-33 A9N61526 C60H-DC 2P 6A C 500Vdc A-35
18750 NG125L 2P 10A B A-33 18829 NG125L 4P 80A C A-33 A9N61528 C60H-DC 2P 10A C 500Vdc A-35
18751 NG125L 2P 16A B A-33 18830 NG125L 1P 10A D A-33 A9N61529 C60H-DC 2P 13A C 500Vdc A-35
18752 NG125L 2P 20A B A-33 18831 NG125L 1P 16A D A-33 A9N61530 C60H-DC 2P 15A C 500Vdc A-35
18753 NG125L 2P 25A B A-33 18832 NG125L 1P 20A D A-33 A9N61531 C60H-DC 2P 16A C 500Vdc A-35
18754 NG125L 2P 32A B A-33 18833 NG125L 1P 25A D A-33 A9N61532 C60H-DC 2P 20A C 500Vdc A-35
18755 NG125L 2P 40A B A-33 18834 NG125L 1P 32A D A-33 A9N61533 C60H-DC 2P 25A C 500Vdc A-35
18756 NG125L 2P 50A B A-33 18835 NG125L 1P 40A D A-33 A9N61534 C60H-DC 2P 30A C 500Vdc A-35
18757 NG125L 2P 63A B A-33 18836 NG125L 1P 50A D A-33 A9N61535 C60H-DC 2P 32A C 500Vdc A-35
18758 NG125L 2P 80A B A-33 18837 NG125L 1P 63A D A-33 A9N61537 C60H-DC 2P 40A C 500Vdc A-35
18759 NG125L 3P 10A B A-33 18838 NG125L 1P 80A D A-33 A9N61538 C60H-DC 2P 50A C 500Vdc A-35
18760 NG125L 3P 16A B A-33 18839 NG125L 2P 10A D A-33 A9N61539 C60H-DC 2P 63A C 500Vdc A-35
18761 NG125L 3P 20A B A-33 18840 NG125L 2P 16A D A-33 A9F90204 IC60L MA 2P 4A A-39
18762 NG125L 3P 25A B A-33 18841 NG125L 2P 20A D A-33 A9F90210 IC60L MA 2P 10A A-39
18763 NG125L 3P 32A B A-33 18842 NG125L 2P 25A D A-33 A9F90216 IC60L MA 2P 16A A-39
18764 NG125L 3P 40A B A-33 18843 NG125L 2P 32A D A-33 A9F90225 IC60L MA 2P 25A A-39
18765 NG125L 3P 50A B A-33 18844 NG125L 2P 40A D A-33 A9F90240 IC60L MA 2P 40A A-39
18766 NG125L 3P 63A B A-33 18845 NG125L 2P 50A D A-33 A9F90272 IC60L MA 2P 1.6A A-39
18767 NG125L 3P 80A B A-33 18846 NG125L 2P 63A D A-33 A9F90273 IC60L MA 2P 2.5A A-39
18768 NG125L 4P 10A B A-33 18847 NG125L 2P 80A D A-33 A9F90276 IC60L MA 2P 6.3A A-39
18769 NG125L 4P 16A B A-33 18848 NG125L 3P 10A D A-33 A9F90282 IC60L MA 2P 12.5A A-39
18770 NG125L 4P 20A B A-33 18849 NG125L 3P 16A D A-33 A9F90304 IC60L MA 3P 4A A-39
18771 NG125L 4P 25A B A-33 18850 NG125L 3P 20A D A-33 A9F90310 IC60L MA 3P 10A A-39
18772 NG125L 4P 32A B A-33 18851 NG125L 3P 25A D A-33 A9F90316 IC60L MA 3P 16A A-39
18773 NG125L 4P 40A B A-33 18852 NG125L 3P 32A D A-33 A9F90325 IC60L MA 3P 25A A-39
18774 NG125L 4P 50A B A-33 18853 NG125L 3P 40A D A-33 A9F90340 IC60L MA 3P 40A A-39
18775 NG125L 4P 63A B A-33 18854 NG125L 3P 50A D A-33 A9F90372 IC60L MA 3P 1.6A A-39
18776 NG125L 4P 80A B A-33 18855 NG125L 3P 63A D A-33 A9F90373 IC60L MA 3P 2.5A A-39
18777 NG125L 1P 10A C A-33 18856 NG125L 3P 80A D A-33 A9F90376 IC60L MA 3P 6.3A A-39
18778 NG125L 1P 16A C A-33 18857 NG125L 4P 10A D A-33 A9F90382 IC60L MA 3P 12.5A A-39
18779 NG125L 1P 20A C A-33 18858 NG125L 4P 16A D A-33 18868 NG125L 2P 4A MA A-42
18780 NG125L 1P 25A C A-33 18859 NG125L 4P 20A D A-33 18869 NG125L 2P 6.3A MA A-42
18781 NG125L 1P 32A C A-33 18860 NG125L 4P 25A D A-33 18870 NG125L 2P 10A MA A-42
18782 NG125L 1P 40A C A-33 18861 NG125L 4P 32A D A-33 18871 NG125L 2P 12.5A MA A-42
18783 NG125L 1P 50A C A-33 18862 NG125L 4P 40A D A-33 18872 NG125L 2P 16A MA A-42
18784 NG125L 1P 63A C A-33 18863 NG125L 4P 50A D A-33 18873 NG125L 2P 25A MA A-42

Acti 9 | Catalogue 2014 11


Index

Reference Description Page Reference Description Page Reference Description Page


18874 NG125L 2P 40A MA A-42 A9R71463 iID 4P 63A 30mA AC-type B-7 A9R50425 ILD K AC 30MA25A 4P B-11
18875 NG125L 2P 63A MA A-42 A9R74225 iID 2P 25A 300mA AC-type B-7 A9R50440 ILD K AC 30MA50A 4P B-11
18876 NG125L 2P 80A MA A-42 A9R74240 iID 2P 40A 300mA AC-type B-7 A9R70463 ILD K AC 30MA63A 4P B-11
18879 NG125L 3P 4A MA A-42 A9R74263 iID 2P 63A 300mA AC-type B-7 A9R75225 ILD K AC 300MA25A 2P B-11
18880 NG125L 3P 6.3A MA A-42 A9R74425 iID 4P 25A 300mA AC-type B-7 A9R75240 ILD K AC 300MA40A 2P B-11
18881 NG125L 3P 10A MA A-42 A9R74440 iID 4P 40A 300mA AC-type B-7 A9R75425 ILD K AC 300MA 25A 4P B-11
18882 NG125L 3P 12,5A MA A-42 A9R74463 iID 4P 63A 300mA AC-type B-7 A9R75440 ILD K AC 300MA40A 4P B-11
18883 NG125L 3P 16A MA A-42 A9R20216 iID 2P 16A 10mA A-type B-8 A9R75463 ILD K AC 300MA63A 4P B-11
18884 NG125L 3P 25A MA A-42 A9R20225 iID 2P 25A 10mA A-type B-8 16905 RCCB 4P 125A 30MA 72MM B-13
18885 NG125L 3P 40A MA A-42 A9R21291 iID 2P 100A 30mA A-type B-8 16906 RCCB 4P 125A 100MA 72MM B-13
18886 NG125L 3P 63A MA A-42 A9R21480 iID 4P 80A 30mA A-type B-8 16907 RCCB 4P 125A 300MA 72MM B-13
18887 NG125L 3P 80A MA A-44 A9R21491 iID 4P 100A 30mA A-type B-8 16908 RCCB 4P 125A 500MA 72MM B-13
A9N15635 Acti-9 STI 1P 8,5X31,5 400V A-44 A9R22440 iID 4P 40A 100mA A-type B-8 16920 RCCB SI 4P 125A 30MA 72MM B-13
A9N15636 Acti-9 STI 1P 10,3X38 500V A-44 A9R22463 iID 4P 63A 100mA A-type B-8 16921 RCCB SI 4P 125A 300MA A B-13
A9N15645 Acti-9 STI 1P N 8,5X31,5 400V A-44 A9R24291 iID 2P 100A 300mA A-type B-8 16924 RCCB 4P 125A 30MA A 72MM B-13
A9N15646 Acti-9 STI 1P N 10,3X38 500V A-44 A9R24480 iID 4P 80A 300mA A-type B-8 16925 RCCB 4P 125A 300MA A S B-13
A9N15650 Acti-9 STI 2P 8,5X31,5 400V A-44 A9R24491 iID 4P 100A 300mA A-type B-8 16926 RCCB 4P 125A 300MA A 72MM B-13
A9N15651 Acti-9 STI 2P 10,3X38 500V A-44 A9R25240 iID 2P 40A 300mA-S A-type B-8 16927 RCCB 4P 125A 500MA A 72MM B-13
A9N15655 Acti-9 STI 3P 8,5X31,5 400V A-44 A9R25263 iID 2P 63A 300mA-S A-type B-8 16938 10 TERM.SCREW SHIELD 2P B-13
A9N15656 Acti-9 STI 3P 10,3X38 500V A-44 A9R25291 iID 2P 100A 300mA-S A-type B-8 16939 10 TERM.SCREW SHIELD 4P B-13
A9N15657 Acti-9 STI 3P N 8,5X31,5 400V A-44 A9R25440 iID 4P 40A 300mA-S A-type B-8 16940 AUXILIARY OFSP FOR RCCB B-13
A9N15658 Acti-9 STI 3P N 10,3X38 500V A-44 A9R25463 iID 4P 63A 300mA-S A-type B-8 16966 RCCB 2P 125A 30MA IEC1008 B-13
A9R10216 iID 2P 16A 10mA AC-type B-7 A9R25480 iID 4P 80A 300mA-S A-type B-8 16967 RCCB 2P 125A 300MA IEC1008 B-13
A9R10225 iID 2P 25A 10mA AC-type B-7 A9R25491 iID 4P 100A 300mA-S A-type B-8 16970 RCCB 2P 125A 30MA A 72MM B-13
A9R11280 iID 2P 80A 30mA AC-type B-7 A9R26440 iID 4P 40A 500mA A-type B-8 16971 RCCB 2P 125A 300MA B-13
A9R11291 iID 2P 100A 30mA AC-type B-7 A9R26463 iID 4P 63A 500mA A-type B-8 16972 RCCB 2P 125A 30MA A SI B-13
A9R11480 iID 4P 80A 30mA AC-type B-7 A9R26491 iID 4P 100A 500mA A-type B-8 16973 RCCB 2P 125A 300MA SI B-13
A9R11491 iID 4P 100A 30mA AC-type B-7 A9R21225 ilD 2P 25A 30mA A-type B-8 16750 ID 4P 25A 30MA B B-15
A9R12240 iID 2P 40A 100mA AC-type B-7 A9R21240 ilD 2P 40A 30mA A-type B-8 16751 ID 4P 25A 300MA B B-15
A9R12263 iID 2P 63A 100mA AC-type B-7 A9R21263 ilD 2P 63A 30mA A-type B-8 16752 RCCB 4P 40A 30mA B type B-15
A9R12280 iID 2P 80A 100mA AC-type B-7 A9R21425 ilD 4P 25A 30mA A-type B-8 16753 ID 4P 40A 300MA B B-15
A9R12291 iID 2P 100A 100mA AC-type B-7 A9R21440 ilD 4P 40A 30mA A-type B-8 16754 ID 4P 40A 300MA S B B-15
A9R12440 iID 4P 40A 100mA AC-type B-7 A9R21463 ilD 4P 63A 30mA A-type B-8 16755 ID 4P 40A 500MA B B-15
A9R12463 iID 4P 63A 100mA AC-type B-7 A9R24225 ilD 2P 25A 300mA A-type B-8 16756 ID 4P 63A 30MA B B-15
A9R12480 iID 4P 80A 100mA AC-type B-7 A9R24240 ilD 2P 40A 300mA A-type B-8 16757 ID 4P 63A 300MA B B-15
A9R12491 iID 4P 100A 100mA AC-type B-7 A9R24263 ilD 2P 63A 300mA A-type B-8 16758 ID 4P 63A 300MA S B B-15
A9R14280 iID 2P 80A 300mA AC-type B-7 A9R24425 ilD 4P 25A 300mA A-type B-8 16759 RCCB 4P 63A 500MA B B-15
A9R14291 iID 2P 100A 300mA AC-type B-7 A9R24440 ilD 4P 40A 300mA A-type B-8 16760 ID 4P 80A 30MA B B-15
A9R14480 iID 4P 80A 300mA AC-type B-7 A9R24463 ilD 4P 63A 300mA A-type B-8 16761 ID 4P 80A 300MA B B-15
A9R14491 iID 4P 100A 300mA AC-type B-7 A9R30225 iID 2P 25A 10mA ASI-type B-9 16762 ID 4P 80A 300MA S B B-15
A9R15263 iID 2P 63A 300mA-S AC-type B-7 A9R31480 iID 4P 80A 30mA ASI-type B-9 16763 ID 4P 125A 30MA B B-15
A9R15280 iID 2P 80A 300mA-S AC-type B-7 A9R31491 iID 4P 100A 30mA ASI-type B-9 16764 ID 4P 125A 300MA B B-15
A9R15291 iID 2P 100A 300mA-S AC-type B-7 A9R34463 iID 4P 63A 300mA ASI-type B-9 16765 RCCB 4P 125A 300MA S B B-15
A9R15440 iID 4P 40A 300mA-S AC-type B-7 A9R34491 iID 4P 100A 300mA ASI-type B-9 16766 ID 4P 125A 500MA B B-15
A9R15463 iID 4P 63A 300mA-S AC-type B-7 A9R35240 iID 2P 40A 300mA-S ASI-type B-9 A9V10225 Vigi iC60 2P 25A 10mA AC-type B-17
A9R15480 iID 4P 80A 300mA-S AC-type B-7 A9R35263 iID 2P 63A 300mA-S ASI-type B-9 A9V12225 Vigi iC60 2P 25A 100mA AC-type B-17
A9R15491 iID 4P 100A 300mA-S AC-type B-7 A9R35291 iID 2P 100A 300mA-S ASI-type B-9 A9V12263 Vigi iC60 2P 63A 100mA AC-type B-17
A9R16225 iID 2P 25A 500mA AC-type B-7 A9R35440 iID 4P 40A 300mA-S ASI-type B-9 A9V12425 Vigi iC60 4P 25A 100mA AC-type B-17
A9R16240 iID 2P 40A 500mA AC-type B-7 A9R35463 iID 4P 63A 300mA-S ASI-type B-9 A9V12463 Vigi iC60 4P 63A 100mA AC-type B-17
A9R16263 iID 2P 63A 500mA AC-type B-7 A9R35480 iID 4P 80A 300mA-S ASI-type B-9 A9V15263 Vigi iC60 2P 63A 300mA-S AC-type B-17
A9R16425 iID 4P 25A 500mA AC-type B-7 A9R35491 iID 4P 100A 300mA-S ASI-type B-9 A9V15363 Vigi iC60 3P 63A 300mA-S AC-type B-17
A9R16440 iID 4P 40A 500mA AC-type B-7 A9R37440 iID 4P 40A 500mA-S ASI-type B-9 A9V15463 Vigi iC60 4P 63A 300mA-S AC-type B-17
A9R16463 iID 4P 63A 500mA AC-type B-7 A9R37463 iID 4P 63A 500mA-S ASI-type B-9 A9V16225 Vigi iC60 2P 25A 500mA AC-type B-17
A9R16480 iID 4P 80A 500mA AC-type B-7 A9R37480 iID 4P 80A 500mA-S ASI-type B-9 A9V16240 Vigi iC60 2P 40A 500mA AC-type B-17
A9R17440 iID 4P 40A 500mA-S AC-type B-7 A9R61225 iID 2P 25A 30mA ASI-type B-9 A9V16263 Vigi iC60 2P 63A 500mA AC-type B-17
A9R17463 iID 4P 63A 500mA-S AC-type B-7 A9R61240 iID 2P 40A 30mA ASI-type B-9 A9V16325 Vigi iC60 3P 25A 500mA AC-type B-17
A9R17480 iID 4P 80A 500mA-S AC-type B-7 A9R61263 iID 2P 63A 30mA ASI-type B-9 A9V16340 Vigi iC60 3P 40A 500mA AC-type B-17
A9R71225 iID 2P 25A 30mA AC-type B-7 A9R61425 iID 4P 25A 30mA ASI-type B-9 A9V16363 Vigi iC60 3P 63A 500mA AC-type B-17
A9R71240 iID 2P 40A 30mA AC-type B-7 A9R61440 iID 4P 40A 30mA ASI-type B-9 A9V16425 Vigi iC60 4P 25A 500mA AC-type B-17
A9R71263 iID 2P 63A 30mA AC-type B-7 A9R61463 iID 4P 63A 30mA ASI-type B-9 A9V16440 Vigi iC60 4P 40A 500mA AC-type B-17
A9R71425 iID 4P 25A 30mA AC-type B-7 A9R50225 ILD K AC 30MA 25A 2P B-11 A9V16463 Vigi iC60 4P 63A 500mA AC-type B-17
A9R71440 iID 4P 40A 30mA AC-type B-7 A9R50240 ILD K AC 30MA40A 2P B-11 A9V19263 Vigi iC60 2P 63A 1000mA-S AC-type B-17

12 Acti 9 | Catalogue 2014


Index

Reference Description Page Reference Description Page Reference Description Page


A9V19363 Vigi iC60 3P 63A 1000mA-S AC-type B-17 A9V61325 Vigi iC60 3P 25A 30mA A-SI-type B-19 19001 VIGI NG125 2P 63A 300MA B-28
A9V19463 Vigi iC60 4P 63A 1000mA-S AC-type B-17 A9V61340 Vigi iC60 3P 40A 30mA A-SI-type B-19 19002 VIGI NG125 3P 63A 30MA B-28
A9V41225 Vigi iC60 2P 25A 30mA AC-type B-17 A9V61363 Vigi iC60 3P 63A 30mA A-SI-type B-19 19003 VIGI NG125 3P 63A 300MA B-28
A9V41240 Vigi iC60 2P 40A 30mA AC-type B-17 A9V61425 Vigi iC60 4P 25A 30mA A-SI-type B-19 19004 VIGI NG125 4P 63A 30MA B-28
A9V41263 Vigi iC60 2P 63A 30mA AC-type B-17 A9V61440 Vigi iC60 4P 40A 30mA A-SI-type B-19 19005 VIGI NG125 4P 63A 300MA B-28
A9V41325 Vigi iC60 3P 25A 30mA AC-type B-17 A9V61463 Vigi iC60 4P 63A 30mA A-SI-type B-19 19008 VIGI NG125 30MA 2P 63A B-29
A9V41340 Vigi iC60 3P 40A 30mA AC-type B-17 A9V65263 Vigi iC60 2P 63A 300mA-S A-SI-type B-19 19009 VIGI NG125 300MA 2P 63A B-29
A9V41363 Vigi iC60 3P 63A 30mA AC-type B-17 A9V65363 Vigi iC60 3P 63A 300mA-S A-SI-type B-19 19010 VIGI NG125 2P 63A 30MA A B-29
A9V41425 Vigi iC60 4P 25A 30mA AC-type B-17 A9V65463 Vigi iC60 4P 63A 300mA-S A-SI-type B-19 19012 VIGI NG125 30MA 2P 63A B-29
A9V41440 Vigi iC60 4P 40A 30mA AC-type B-17 A9N18542 VIGI C120 2P 125A 30MA B-23 19013 VIGI NG125 3P 63A 30MA 230-415V B-29
A9V41463 Vigi iC60 4P 63A 30mA AC-type B-17 A9N18543 VIGI C120 2P 125A 300MA B-23 19014 VIGI NG125 3P 63A 300MA 230-415V B-29
A9V44225 Vigi iC60 2P 25A 300mA AC-type B-17 A9N18544 VIGI C120 2P 125A 300MA S B-23 19015 VIGI NG125 4P 63A 30MA A B-29
A9V44240 Vigi iC60 2P 40A 300mA AC-type B-17 A9N18545 VIGI C120 2P 125A 1000MA S B-23 19016 VIGI NG125 4P 63A 300MA A B-29
A9V44263 Vigi iC60 2P 63A 300mA AC-type B-17 A9N18546 VIGI C120 3P 125A 300MA S B-23 19030 VIGI NG125 4P 63A 300MA/S A B-29
A9V44325 Vigi iC60 3P 25A 300mA AC-type B-17 A9N18547 VIGI C120 3P 125A 1000MA S B-23 19031 Vigi NG125 2P 63A 1000mA s B-29
A9V44340 Vigi iC60 3P 40A 300mA AC-type B-17 A9N18548 VIGI C120 4P 125A 300MA S B-23 19032 VIGI NG125 3P 63A 300MA A s B-29
A9V44363 Vigi iC60 3P 63A 300mA AC-type B-17 A9N18549 VIGI C120 4P 125A 1000MA S B-23 19033 Vigi NG125 3P 63A 1000mA s B-29
A9V44425 Vigi iC60 4P 25A 300mA AC-type B-17 A9N18563 VIGI C120 2P 125A 30MA B-23 19034 VIGI NG125 4P 63A 300MA S A B-29
A9V44440 Vigi iC60 4P 40A 300mA AC-type B-17 A9N18564 VIGI C120 2P 125A 300MA B-23 19035 VIGI NG125 4P 63A 1000MA S A B-29
A9V44463 Vigi iC60 4P 63A 300mA AC-type B-17 A9N18565 VIGI C120 2P 125A 500MA B-23 19036 Vigi NG125 3P 63A 300-3000 mA s B-29
A9V01225* Vigi iC60 2P 25A 30mA AC-type 130V B-17 A9N18566 VIGI C120 3P 125A 30MA B-23 19037 Vigi NG125 4P 63A 300-3000 mA s B-29
A9V01240* Vigi iC60 2P 40A 30mA AC-type 130V B-17 A9N18567 VIGI C120 3P 125A 300MA B-23 19039 VIGI NG125 3P 125A 30mA A B-29
A9V01263* Vigi iC60 2P 63A 30mA AC-type 130V B-17 A9N18568 VIGI C120 3P 125A 500MA B-23 19041 VIGI NG125 4P 125A 30MA A B-29
A9V04225* Vigi iC60 2P 25A 300mA AC-type 130V B-17 A9N18569 VIGI C120 4P 125A 30MA B-23 19042 VIGI NG125 4P 125A 300MA A B-29
A9V04240* Vigi iC60 2P 40A 300mA AC-type 130V B-17 A9N18570 VIGI C120 4P 125A 300MA B-23 19044 VIGI NG125 3P 125A A REGLABLE B-29
A9V04263* Vigi iC60 2P 63A 300mA AC-type 130V B-17 A9N18571 VIGI C120 4P 125A 500MA B-23 19046 VIGI NG125 4P 125A A 0,3-0,5-1A B-29
A9V22225 VIGI IC60 A 100MA 25A 2P B-18 A9N18572 VIGI C120 2P 125A 30MA A B-24 19047 VIGI NG125 3P 125A A REGL B-29
A9V22263 VIGI IC60 A 100MA 63A 2P B-18 A9N18573 VIGI C120 2P 125A 300MA A B-24 19049 VIGI NG125 4P 125A A REGL B-29
A9V22325 VIGI IC60 A 100MA 25A 3P B-18 A9N18574 VIGI C120 2P 125A 500MA A B-24 19100 VG_NG125 3P 125A 30MA A SI REGL. B-30
A9V22425 VIGI IC60 A 100MA 25A 4P B-18 A9N18575 VIGI C120 3P 125A 30MA A B-24 19101 VG_NG125 4P 125A 30MA A SI REGL. B-30
VG_NG125 3P 125A 300MA-3000mA SI
A9V22463 VIGI IC60 A 100MA 63A 4P B-18 A9N18576 VIGI C120 3P 125A 300MA A B-24 19106 B-30
REGL.
VG_NG125 4P 125A 300MA-3000mA SI
A9V25263 VIGI IC60 A 300MAS 63A 2P B-18 A9N18577 VIGI C120 3P 125A 500MA A B-24 19107 B-30
REGL.
A9V25363 VIGI IC60 A 300MAS 63A 3P B-18 A9N18578 VIGI C120 4P 125A 30MA A B-24 A9N21741 VIGI DPN_C P+N 25A 30MA B-33
A9V25463 VIGI IC60 A 300MAS 63A 4P B-18 A9N18579 VIGI C120 4P 125A 300MA A B-24 A9N21742 VIGI DPN_C P+N 25A 300MA B-33
A9V26225 VIGI IC60 A 500MA 25A 2P B-18 A9N18580 VIGI C120 4P 125A 500MA A B-24 A9N21743 VIGI DPN_C P+N 40A 30MA B-33
A9V26263 VIGI IC60 A 500MA 63A 2P B-18 A9N18587 VIGI C120 4P 125A 300MA S A B-24 A9N21744 VIGI DPN_C P+N 40A 300MA B-33
A9V26325 VIGI IC60 A 500MA 25A 3P B-18 A9N18588 VIGI C120 4P 125A 500MA S A B-24 A9N21745 VIGI DPN_C P+N 25A 30MA A B-33
A9V26363 VIGI IC60 A 500MA 63A 3P B-18 A9N18589 VIGI C120 4P 125A 1000MA/S A B-24 A9N21746 VIGI DPN_C P+N 25A 300MA A B-33
A9V26425 VIGI IC60 A 500MA 25A 4P B-18 A9N18581 VIGI C120 2P 125A 300MA S A B-24 A9N21747 VIGI DPN_C P+N 40A 30MA A B-33
A9V26463 VIGI IC60 A 500MA 63A 4P B-18 A9N18582 VIGI C120 2P 125A 500MA S A B-24 A9N21748 VIGI DPN_C P+N 40A 300MA A B-33
A9V29263 VIGI IC60 A 1000MAS 63A 2P B-18 A9N18583 VIGI C120 2P 125A 1000MA/S A B-24 A9N21749 VIGI DPN_C P+N 25A 30MA A SI B-33
A9V29363 VIGI IC60 A 1000MAS 63A 3P B-18 A9N18584 VIGI C120 3P 125A 300MA S A B-24 A9N21750 VIGI DPN_C P+N 25A 300MA A SI B-33
A9V29463 VIGI IC60 A 1000MAS 63A 4P B-18 A9N18585 VIGI C120 3P 125A 500MA S A B-24 A9N21751 VIGI DPN_C P+N 40A 30MA A SI B-33
A9V51225 VIGI IC60 A 30MA 25A 2P B-18 A9N18586 VIGI C120 3P 125A 1000MA/S A B-24 A9N21752 VIGI DPN_C P+N 40A 300MA A SI B-33
A9V51263 VIGI IC60 A 30MA 63A 2P B-18 A9N18554 VIGI C120 4P 30mA SI B-25 A9N21753 VIGI DPN_C P+N 40A 300MA/S A SI B-33
A9V51325 VIGI IC60 A 30MA 25A 3P B-18 A9N18555 VIGI C120 4P 300mA SI B-25 A9N21755 VIGI DPN C 3P+N 25A CL.AC TYPE I30MA B-33
VIGI DPN C 3P+N 25A CL.AC TYPE
A9V51363 VIGI IC60 A 30MA 63A 3P B-18 A9N18556 VIGI C120 2P 125A 300MA/S A SI B-25 A9N21756 B-33
I300MA
A9V51425 VIGI IC60 A 30MA 25A 4P B-18 A9N18557 VIGI C120 2P 125A 1000MA/S A SI B-25 A9N21757 VIGI DPN C 3P+N 40A CL.AC TYPE I30MA B-33
VIGI DPN C 3P+N 40A CL.AC TYPE
A9V51463 VIGI IC60 A 30MA 63A 4P B-18 A9N18558 VIGI C120 3P 125A 300MA/S A SI B-25 A9N21758 B-33
I300MA
A9V54225 VIGI IC60 A 300MA 25A 2P B-18 A9N18559 VIGI C120 3P 125A 1000MA/S A SI B-25 A9N21759 VIGI DPN C 3P+N 25A CL.A TYPE I 30MA B-33
A9V54263 VIGI IC60 A 300MA 63A 2P B-18 A9N18560 VIGI C120 4P 125A 300MA/S A SI B-25 A9N21760 VIGI DPN C 3P+N 25A CL.A TYPE I 300MA B-33
A9V54325 VIGI IC60 A 300MA 25A 3P B-18 A9N18561 VIGI C120 4P 125A 1000MA/S A SI B-25 A9N21761 VIGI DPN C 3P+N 40A CL.A TYPE I 30MA B-33
A9V54363 VIGI IC60 A 300MA 63A 3P B-18 A9N18591 VIGI C120 2P 125A 30MA A SI B-25 A9N21762 VIGI DPN C 3P+N 40A CL.A TYPE I 300MA B-33
VIGI DPN C 3P+N 25A CL.ASI TYPE I
A9V54425 VIGI IC60 A 300MA 25A 4P B-18 A9N18592 VIGI C120 2P 125A 300MA A SI B-25 A9N21763 B-33
30MA
VIGI DPN C 3P+N 25A CL.ASI TYPE I
A9V54463 VIGI IC60 A 300MA 63A 4P B-18 A9N18594 VIGI C120 3P 125A 30MA A SI B-25 A9N21764 B-33
300MA
VIGI DPN C 3P+N 40A CL.ASI TYPE I
A9V30225 Vigi iC60 2P 25A 10mA A-SI-type B-19 A9N18595 VIGI C120 3P 125A 300MA A SI B-25 A9N21765 B-33
30MA
VIGI DPN C 3P+N 40A CL.ASI TYPE I
A9V39263 Vigi iC60 2P 63A 1000mA-S A-SI-type B-19 A9N18597 VIGI C120 4P 125A 30MA A SI B-25 A9N21766 B-33
300MA
VIGI DPN C 3P+N 40A CL.ASI TYPE S
A9V39363 Vigi iC60 3P 63A 1000mA-S A-SI-type B-19 A9N18598 VIGI C120 4P 125A 300MA A SI B-25 A9N21767 B-33
300MA
VIGI DPN 4500 CL . AC TYPE C 30mA 25
A9V39463 Vigi iC60 4P 63A 1000mA-S A-SI-type B-19 A9N18599 VIGI C120 4P 125A 500MA A SI B-25 A9N21771 B-33
A 3P+N
VIGI DPN 4500 CL . AC TYPE C 300mAS
A9V61225 Vigi iC60 2P 25A 30mA A-SI-type B-19 A9N18593 VIGI C120 2P 125A 500MA A SI B-25 A9N21772 B-33
25 A 3P+N
VIGI DPN 4500 CL . AC TYPE C 30mA 40
A9V61240 Vigi iC60 2P 40A 30mA A-SI-type B-19 A9N18596 VIGI C120 3P 125A 500MA A SI B-25 A9N21773 B-33
A 3P+N
VIGI DPN 4500 CL . AC TYPE C 300mAS
A9V61263 Vigi iC60 2P 63A 30mA A-SI-type B-19 19000 VIGI NG125 2P 63A 30MA B-28 A9N21774 B-33
25 A 3P+N

Acti 9 | Catalogue 2014 13


Index

Reference Description Page Reference Description Page Reference Description Page


VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21775 B-33 A9D34610 iDPNa Vigi 10A C 30mA AC-type B-35 A9D32625 iDPN N Vigi 25A C 30mA A-type B-36
25 A 3P+N
VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21776 B-33 A9D34616 iDPNa Vigi 16A C 30mA AC-type B-35 A9D32632 iDPN N Vigi 32A C 30mA A-type B-36
40 A 3P+N
A9N26846 VIGI DPN C 3P+N 63A CL.AC TYPE I30MA B-33 A9D34620 iDPNa Vigi 20A C 30mA AC-type B-35 A9D32640 iDPN N Vigi 40A C 30mA A-type B-36
VIGI DPN C 3P+N 63A CL.AC TYPE
A9N26847 B-33 A9D34625 iDPNa Vigi 25A C 30mA AC-type B-35 A9D33606 iDPN N Vigi 6A C 30mA SI-type B-36
I300MA
VIGI DPN C 3P+N 63A CL.AC TYPE
A9N26848 B-33 A9D34632 iDPNa Vigi 32A C 30mA AC-type B-35 A9D33610 iDPN N Vigi 10A C 30mA SI-type B-36
I300MAS
A9N26849 VIGI DPN C 3P+N 63A CL.SI TYPE I30MA B-33 A9D34640 iDPNa Vigi 40A C 30mA AC-type B-35 A9D33613 iDPN N Vigi 13A C 30mA SI-type B-36
VIGI DPN 4500 CL . AC TYPE C 30mA 6
A9N21614 B-34 A9D35606 iDPNa Vigi 6A C 30mA A-type B-35 A9D33616 iDPN N Vigi 16A C 30mA SI-type B-36
A 1P+N
VIGI DPN 4500 CL . AC TYPE C 30mA 10
A9N21615 B-34 A9D35610 iDPNa Vigi 10A C 30mA A-type B-35 A9D33620 iDPN N Vigi 20A C 30mA SI-type B-36
A 1P+N
VIGI DPN 4500 CL . AC TYPE C 30mA 16
A9N21616 B-34 A9D35613 iDPNa Vigi 13A C 30mA A-type B-35 A9D33625 iDPN N Vigi 25A C 30mA SI-type B-36
A 1P+N
VIGI DPN 4500 CL . AC TYPE C 30mA 20
A9N21617 B-34 A9D35616 iDPNa Vigi 16A C 30mA A-type B-35 A9D33632 iDPN N Vigi 32A C 30mA SI-type B-36
A 1P+N
VIGI DPN 4500 CL . AC TYPE C 30mA 25
A9N21618 B-34 A9D35620 iDPNa Vigi 20A C 30mA A-type B-35 A9D33640 iDPN N Vigi 40A C 30mA SI-type B-36
A 1P+N
VIGI DPN 4500 CL . AC TYPE C 30mA 32
A9N21619 B-34 A9D35625 iDPNa Vigi 25A C 30mA A-type B-35 A9D37606 iDPN H Vigi 6A C 30mA A-type B-36
A 1P+N
VIGI DPN 4500 CL . AC TYPE C 30mA 40
A9N21620 B-34 A9D35632 iDPNa Vigi 32A C 30mA A-type B-35 A9D37610 iDPN H Vigi 10A C 30mA A-type B-36
A 1P+N
VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21624 B-34 A9D35640 iDPNa Vigi 40A C 30mA A-type B-35 A9D37616 iDPN H Vigi 16A C 30mA A-type B-36
6 A 1P+N
VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21625 B-34 A9D44606 iDPNa Vigi 6A C 300mA AC-type B-35 A9D37620 iDPN H Vigi 20A C 30mA A-type B-36
10 A 1P+N
VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21626 B-34 A9D44610 iDPNa Vigi 10A C 300mA AC-type B-35 A9D37625 iDPN H Vigi 25A C 30mA A-type B-36
16 A 1P+N
VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21627 B-34 A9D44616 iDPNa Vigi 16A C 300mA AC-type B-35 A9D37632 iDPN H Vigi 32A C 30mA A-type B-36
20 A 1P+N
VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21628 B-34 A9D44620 iDPNa Vigi 20A C 300mA AC-type B-35 A9D38606 iDPN H Vigi 6A C 30mA SI-type B-36
25 A 1P+N
VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21629 B-34 A9D44625 iDPNa Vigi 25A C 300mA AC-type B-35 A9D38610 iDPN H Vigi 10A C 30mA SI-type B-36
32 A 1P+N
VIGI DPN 4500 CL . AC TYPE C 300mA
A9N21630 B-34 A9D44632 iDPNa Vigi 32A C 300mA AC-type B-35 A9D38616 iDPN H Vigi 16A C 30mA SI-type B-36
40 A 1P+N
A9N21680 VIGI I_DPN 1P+N 25A 30MA TYPE G B-34 A9D44640 iDPNa Vigi 40A C 300mA AC-type B-35 A9D38620 iDPN H Vigi 20A C 30mA SI-type B-36
A9N21681 VIGI I_DPN 1P+N 25A 30MA B-34 A9D51606 iDPNa Vigi 6A B 30mA AC-type B-35 A9D38625 iDPN H Vigi 25A C 30mA SI-type B-36
A9N21682 VIGI I_DPN 1P+N 25A 300MA B-34 A9D51610 iDPNa Vigi 10A B 30mA AC-type B-35 A9D38632 iDPN H Vigi 32A C 30mA SI-type B-36
A9N21683 VIGI I_DPN 1P+N 40A 30MA B-34 A9D51616 iDPNa Vigi 16A B 30mA AC-type B-35 A9D41606 iDPN N Vigi 6A C 300mA AC-type B-36
A9N21684 VIGI I_DPN 1P+N 40A 300MA B-34 A9D51620 iDPNa Vigi 20A B 30mA AC-type B-35 A9D41610 iDPN N Vigi 10A C 300mA AC-type B-36
A9N21685 VIGI I_DPN 1P+N 25A 30MA A B-34 A9D51625 iDPNa Vigi 25A B 30mA AC-type B-35 A9D41616 iDPN N Vigi 16A C 300mA AC-type B-36
A9N21686 VIGI I_DPN 1P+N 25A 300MA A B-34 A9D51632 iDPNa Vigi 32A B 30mA AC-type B-35 A9D41620 iDPN N Vigi 20A C 300mA AC-type B-36
A9N21687 VIGI I_DPN 1P+N 40A 30MA A B-34 A9D51640 iDPNa Vigi 40A B 30mA AC-type B-35 A9D41625 iDPN N Vigi 25A C 300mA AC-type B-36
A9N21688 VIGI I_DPN 1P+N 40A 300MA A B-34 A9D54606 iDPNa Vigi 6A B 30mA A-type B-35 A9D41632 iDPN N Vigi 32A C 300mA AC-type B-36
A9N21689 VIGI I_DPN 1P+N 25A 30MA A SI B-34 A9D54610 iDPNa Vigi 10A B 30mA A-type B-35 A9D41640 iDPN N Vigi 40A C 300mA AC-type B-36
A9N21690 VIGI I_DPN 1P+N 25A 300MA A SI B-34 A9D54613 iDPNa Vigi 13A B 30mA A-type B-35 A9D42606 iDPN N Vigi 6A C 300mA A-type B-36
A9N21691 VIGI I_DPN 1P+N 40A 30MA A SI B-34 A9D54616 iDPNa Vigi 16A B 30mA A-type B-35 A9D42610 iDPN N Vigi 10A C 300mA A-type B-36
A9N21692 VIGI I_DPN 1P+N 40A 300MA A SI B-34 A9D54620 iDPNa Vigi 20A B 30mA A-type B-35 A9D42613 iDPN N Vigi 13A C 300mA A-type B-36
A9N21695 VIGI I DPN 3P 25A CL.AC TYPE I 30MA B-34 A9D54625 iDPNa Vigi 25A B 30mA A-type B-35 A9D42616 iDPN N Vigi 16A C 300mA A-type B-36
A9N21697 VIGI I DPN 3P 40A CL.AC TYPE I 30MA B-34 A9D54632 iDPNa Vigi 32A B 30mA A-type B-35 A9D42620 iDPN N Vigi 20A C 300mA A-type B-36
A9N21699 VIGI I DPN 3P 25A CL.A TYPE I 30MA B-34 A9D54640 iDPNa Vigi 40A B 30mA A-type B-35 A9D42625 iDPN N Vigi 25A C 300mA A-type B-36
IDPN N VIGI GTYPE 6000 1P+N AC 30
A9N21700 VIGI I DPN 3P 25A CL.A TYPE I 300MA B-34 A9D62606 B-35 A9D42632 iDPN N Vigi 32A C 300mA A-type B-36
MA 6A
IDPN N VIGI GTYPE 6000 1P+N AC 30
A9N21701 VIGI I DPN 3P 40A CL.A TYPE I 30MA B-34 A9D62610 B-35 A9D42640 iDPN N Vigi 40A C 300mA A-type B-36
MA 10A
IDPN N VIGI GTYPE 6000 1P+N AC 30
A9N21702 VIGI I DPN 3P 40A CL.A TYPE I 300MA B-34 A9D62613 B-35 A9D43606 iDPN N Vigi 6A C 300mA SI-type B-36
MA 13A
IDPN N VIGI GTYPE 6000 1P+N AC 30
A9N21703 VIGI I DPN 3P 25A CL.A SI TYPE I30MA B-34 A9D62616 B-35 A9D43610 iDPN N Vigi 10A C 300mA SI-type B-36
MA 16A
IDPN N VIGI GTYPE 6000 1P+N AC 300
A9N21704 VIGI I DPN 3P 25A CL.A SI TYPE I300MA B-34 A9D72606 B-35 A9D43613 iDPN N Vigi 13A C 300mA SI-type B-36
MA 6A
IDPN N VIGI GTYPE 6000 1P+N AC 300
A9N21705 VIGI I DPN 3P 40A CL.A SI TYPE I30MA B-34 A9D72610 B-35 A9D43616 iDPN N Vigi 16A C 300mA SI-type B-36
MA 10A
IDPN N VIGI GTYPE 6000 1P+N AC 300
A9N21706 VIGI I DPN 3P 40A CL.A SI TYPE I300MA B-34 A9D72613 B-35 A9D43620 iDPN N Vigi 20A C 300mA SI-type B-36
MA 13A
IDPN N VIGI GTYPE 6000 1P+N AC 300
A9N21709 VIGI DPN 3P+N 25A CL.AC TYPE I 30MA B-34 A9D72616 B-35 A9D43625 iDPN N Vigi 25A C 300mA SI-type B-36
MA 16A
A9N21710 VIGI DPN 3P+N 25A CL.AC TYPE I 300MA B-34 A9D07606 iDPN H Vigi 6A B 30mA A-type B-36 A9D43632 iDPN N Vigi 32A C 300mA SI-type B-36
A9N21711 VIGI DPN 3P+N 40A CL.AC TYPE I 30MA B-34 A9D07610 iDPN H Vigi 10A B 30mA A-type B-36 A9D43640 iDPN N Vigi 40A C 300mA SI-type B-36
A9N21712 VIGI DPN 3P+N 40A CL.AC TYPE I 300MA B-34 A9D07616 iDPN H Vigi 16A B 30mA A-type B-36 A9D47606 iDPN H Vigi 6A C 300mA A-type B-36
A9N21713 VIGI DPN 3P+N 25A CL.A TYPE I 30MA B-34 A9D07620 iDPN H Vigi 20A B 30mA A-type B-36 A9D47610 iDPN H Vigi 10A C 300mA A-type B-36
A9N21714 VIGI DPN 3P+N 25A CL.A TYPE I 300MA B-34 A9D07625 iDPN H Vigi 25A B 30mA A-type B-36 A9D47616 iDPN H Vigi 16A C 300mA A-type B-36
A9N21715 VIGI DPN 3P+N 40A CL.A TYPE I 30MA B-34 A9D07632 iDPN H Vigi 32A B 30mA A-type B-36 A9D47620 iDPN H Vigi 20A C 300mA A-type B-36
A9N21716 VIGI DPN 3P+N 40A CL.A TYPE I 300MA B-34 A9D31606 iDPN N Vigi 6A C 30mA AC-type B-36 A9D47625 iDPN H Vigi 25A C 300mA A-type B-36
A9N21717 VIGI DPN 3P+N 25A CL.A SI TYPE I30MA B-34 A9D31610 iDPN N Vigi 10A C 30mA AC-type B-36 A9D47632 iDPN H Vigi 32A C 300mA A-type B-36
A9N21718 VIGI DPN 3P+N 25A CL.A SI TYPE I300MA B-34 A9D31616 iDPN N Vigi 16A C 30mA AC-type B-36 A9D48606 iDPN H Vigi 6A C 300mA SI-type B-36
A9N21719 VIGI DPN 3P+N 40A CL.A SI TYPE I30MA B-34 A9D31620 iDPN N Vigi 20A C 30mA AC-type B-36 A9D48610 iDPN H Vigi 10A C 300mA SI-type B-36
A9N21720 VIGI DPN 3P+N 40A CL.A SI TYPE I300MA B-34 A9D31625 iDPN N Vigi 25A C 30mA AC-type B-36 A9D48616 iDPN H Vigi 16A C 300mA SI-type B-36
A9N21678 VIGI IDPN AC 100mA 25A B-34 A9D31632 iDPN N Vigi 32A C 30mA AC-type B-36 A9D48620 iDPN H Vigi 20A C 300mA SI-type B-36
A9N21679 VIGI IDPN AC 100mA 25A TYPE G B-34 A9D31640 iDPN N Vigi 40A C 30mA AC-type B-36 A9D48625 iDPN H Vigi 25A C 300mA SI-type B-36
A9N26696 VIGI IDPN AC 300mA 25A B-34 A9D32606 iDPN N Vigi 6A C 30mA A-type B-36 A9D48632 iDPN H Vigi 32A C 300mA SI-type B-36
A9N26698 VIGI IDPN AC 300mA 40A B-34 A9D32610 iDPN N Vigi 10A C 30mA A-type B-36 A9D52606 iDPN N Vigi 6A C 100mA A-type B-36
A9D05610 iDPNa Vigi 10A C 10mA A-type B-35 A9D32613 iDPN N Vigi 13A C 30mA A-type B-36 A9D52610 iDPN N Vigi 10A C 100mA A-type B-36
A9D05616 iDPNa Vigi 16A C 10mA A-type B-35 A9D32616 iDPN N Vigi 16A C 30mA A-type B-36 A9D52613 iDPN N Vigi 13A C 100mA A-type B-36
A9D34606 iDPNa Vigi 6A C 30mA AC-type B-35 A9D32620 iDPN N Vigi 20A C 30mA A-type B-36 A9D52616 iDPN N Vigi 16A C 100mA A-type B-36

14 Acti 9 | Catalogue 2014


Index

Reference Description Page Reference Description Page Reference Description Page


A9D52620 iDPN N Vigi 20A C 100mA A-type B-36 A9D64816 iC60N RCBO 16A+N 30MA C B-39 A9L15686 iPF 40 1P C-2
A9D52625 iDPN N Vigi 25A C 100mA A-type B-36 A9D64820 iC60N RCBO 20A+N 30MA C B-39 A9L15687 iPF 40 1P+N C-2
A9D52632 iDPN N Vigi 32A C 100mA A-type B-36 A9D64825 iC60N RCBO 25A+N 30MA C B-39 A9L15688 iPF 40 3P+N C-2
A9D52640 iDPN N Vigi 40A C 100mA A-type B-36 A9D64832 iC60N RCBO 32A+N 30MA C B-39 A9L15690 iPF 40r 3P+N C-2
A9D53606 iDPN N Vigi 6A C 100mA SI-type B-36 A9D64840 iC60N RCBO 40A+N 30MA C B-39 A9L15691 iPF 20 1P C-2
A9D53610 iDPN N Vigi 10A C 100mA SI-type B-36 A9D64845 iC60N RCBO 45A+N 30MA C B-39 A9L15692 iPF 20 1P+N C-2
A9D53613 iDPN N Vigi 13A C 100mA SI-type B-36 A9D10806 iC60H RCBO 6A+N 10mA C- Blue Neutral B-40 A9L15693 iPF 20 3P+N C-2
A9D53616 iDPN N Vigi 16A C 100mA SI-type B-36 A9D10810 iC60H RCBO 10A+N 10mA C- Blue Neutral B-40 A9L15694 iPF 8 1P C-2
A9D53620 iDPN N Vigi 20A C 100mA SI-type B-36 A9D10816 iC60H RCBO 16A+N 10mA C- Blue Neutral B-40 A9L15695 iPF 8 1P+N C-2
A9D53625 iDPN N Vigi 25A C 100mA SI-type B-36 A9D10820 iC60H RCBO 20A+N 10mA C- Blue Neutral B-40 A9L15696 iPF 8 3P+N C-2
A9D53632 iDPN N Vigi 32A C 100mA SI-type B-36 A9D10832 iC60H RCBO 32A+N 10mA C- Blue Neutral B-40 A9L16442 iPRD 65r 2P C-5
A9D53640 iDPN N Vigi 40A C 100mA SI-type B-36 A9D14806 iC60H RCBO 6A+N 30MA C B-40 A9L16443 iPRD 65r 3P C-5
A9D55604 iDPN N Vigi 4A B 30mA AC-type B-36 A9D14810 iC60H RCBO 10A+N 30MA C B-40 A9L16444 iPRD 40r 2P C-5
A9D55606 iDPN N Vigi 6A B 30mA AC-type B-36 A9D14816 iC60H RCBO 16A+N 30MA C B-40 A9L16445 iPRD40r 3P C-5
A9D55610 iDPN N Vigi 10A B 30mA AC-type B-36 A9D14820 iC60H RCBO 20A+N 30MA C B-40 A9L16446 iPRD 20 2P C-5
A9D55616 iDPN N Vigi 16A B 30mA AC-type B-36 A9D14825 iC60H RCBO 25A+N 30MA C B-40 A9L16447 iPRD 20 3P C-5
A9D55620 iDPN N Vigi 20A B 30mA AC-type B-36 A9D14832 iC60H RCBO 32A+N 30MA C B-40 A9L16448 iPRD 8 2P C-5
A9D55625 iDPN N Vigi 25A B 30mA AC-type B-36 A9D14840 iC60H RCBO 40A+N 30MA C B-40 A9L16449 iPRD 8 3P C-5
A9D55632 iDPN N Vigi 32A B 30mA AC-type B-36 A9D14845 iC60H RCBO 45A+N 30MA C B-40 A9L16555 iPRD 65r 1P IT C-5
A9D55640 iDPN N Vigi 40A B 30mA AC-type B-36 A9D15806 iC60H RCBO 6A+N 100MA C B-40 A9L16556 iPRD 65r 1P C-5
A9D56604 iDPN N Vigi 4A B 30mA A-type B-36 A9D15810 iC60H RCBO 10A+N 100MA C B-40 A9L16557 iPRD 65r 1P+N C-5
A9D56606 iDPN N Vigi 6A B 30mA A-type B-36 A9D15816 iC60H RCBO 16A+N 100MA C B-40 A9L16558 iPRD 65r 3P IT C-5
A9D56610 iDPN N Vigi 10A B 30mA A-type B-36 A9D15820 iC60H RCBO 20A+N 100MA C B-40 A9L16559 iPRD 65r 3P+N C-5
A9D56613 iDPN N Vigi 13A B 30mA A-type B-36 A9D15825 iC60H RCBO 25A+N 100MA C B-40 A9L16561 iPRD 40r 1P C-5
A9D56616 iDPN N Vigi 16A B 30mA A-type B-36 A9D15832 iC60H RCBO 32A+N 100MA C B-40 A9L16562 iPRD 40r 1P+N C-5
A9D56620 iDPN N Vigi 20A B 30mA A-type B-36 A9D15840 iC60H RCBO 40A+N 100MA C B-40 A9L16563 iPRD 40r 3P IT C-5
A9D56625 iDPN N Vigi 25A B 30mA A-type B-36 A9D15845 iC60H RCBO 45A+N 100MA C B-40 A9L16564 iPRD 40r 3P+N C-5
A9D56632 iDPN N Vigi 32A B 30mA A-type B-36 A9D34806 iC60H RCBO 6A+N 30MA B B-40 A9L16566 iPRD 40 1P C-5
A9D56640 iDPN N Vigi 40A B 30mA A-type B-36 A9D34810 iC60H RCBO 10A+N 30MA B B-40 A9L16567 iPRD 40 1P+N C-5
A9D60604 iDPN N Vigi 4A B 100mA A-type B-36 A9D34816 iC60H RCBO 16A+N 30MA B B-40 A9L16568 iPRD 40 3P C-5
A9D60606 iDPN N Vigi 6A B 100mA A-type B-36 A9D34820 iC60H RCBO 20A+N 30MA B B-40 A9L16569 iPRD 40 3P+N C-5
A9D60610 iDPN N Vigi 10A B 100mA A-type B-36 A9D34825 iC60H RCBO 25A+N 30MA B B-40 A9L16571 iPRD 20 1P C-5
A9D60613 iDPN N Vigi 13A B 100mA A-type B-36 A9D34832 iC60H RCBO 32A+N 30MA B B-40 A9L16572 iPRD 20 1P+N C-5
A9D60616 iDPN N Vigi 16A B 100mA A-type B-36 A9D34840 iC60H RCBO 40A+N 30MA B B-40 A9L16573 iPRD 20r 3P IT C-5
A9D60620 iDPN N Vigi 20A B 100mA A-type B-36 A9D34845 iC60H RCBO 45A+N 30MA B B-40 A9L16574 iPRD 20 3P+N C-5
iC60H2 2P 10A C 30mA 10000A A Type
A9D60625 iDPN N Vigi 25A B 100mA A-type B-36 A9D11210 B-41 A9L16576 iPRD 8 1P C-5
RCBO
iC60H2 2P 16A C 30mA 10000A A Type
A9D60632 iDPN N Vigi 32A B 100mA A-type B-36 A9D11216 B-41 A9L16577 iPRD 8 1P+N C-5
RCBO
iC60H2 2P 20A C 30mA 10000A A Type
A9D60640 iDPN N Vigi 40A B 100mA A-type B-36 A9D11220 B-41 A9L16578 iPRD 8r 3P IT C-5
RCBO
iC60H2 2P 25A C 30mA 10000A A Type
A9D68604 iDPN N Vigi 4A B 300mA AC-type B-36 A9D11225 B-41 A9L16579 iPRD 8 3P+N C-5
RCBO
iC60H2 2P 32A C 30mA 10000A A Type
A9D68606 iDPN N Vigi 6A B 300mA AC-type B-36 A9D11232 B-41 A9L16597 iPRD 40r 4P IT C-5
RCBO
iC60H2 2P 10A C 300mA 10000A A Type
A9D68610 iDPN N Vigi 10A B 300mA AC-type B-36 A9D51210 B-41 A9L16599 iPRD 20r 4P IT C-5
RCBO
iC60H2 2P 16A C 300mA 10000A A Type
A9D68616 iDPN N Vigi 16A B 300mA AC-type B-36 A9D51216 B-41 A9L16659 iPRD65r 4P C-5
RCBO
iC60H2 2P 20A C 300mA 10000A A Type
A9D68620 iDPN N Vigi 20A B 300mA AC-type B-36 A9D51220 B-41 A9L16664 iPRD 40r 4P C-5
RCBO
iC60H2 2P 25A C 300mA 10000A A Type
A9D68625 iDPN N Vigi 25A B 300mA AC-type B-36 A9D51225 B-41 A9L16667 iPRD40 2P C-5
RCBO
iC60H2 2P 32A C 300mA 10000A A Type
A9D68632 iDPN N Vigi 32A B 300mA AC-type B-36 A9D51232 B-41 A9L16669 iPRD 40 4P C-5
RCBO
A9D68640 iDPN N Vigi 40A B 300mA AC-type B-36 A9L15581 iPF 65 3P C-2 A9L16672 iPRD 20 r 1P+N C-5
A9D69604 iDPN N Vigi 4A B 300mA A-type B-36 A9L15582 iPF 40 3P C-2 A9L16673 iPRD 20 4P C-5
A9D69606 iDPN N Vigi 6A B 300mA A-type B-36 A9L15584 iPF 65 2P C-2 A9L16674 iPRD 20r 3P+N C-5
A9D69610 iDPN N Vigi 10A B 300mA A-type B-36 A9L15585 iPF 65r 4P C-2 A9L16677 iPRD 8r 1P+N C-5
A9D69613 iDPN N Vigi 13A B 300mA A-type B-36 A9L15586 iPF 65 3P+N C-2 A9L16678 iPRD 8r 4P IT C-5
A9D69616 iDPN N Vigi 16A B 300mA A-type B-36 A9L15587 iPF 40 2P C-2 A9L16679 iPRD 8r 3P+N C-5
A9D69620 iDPN N Vigi 20A B 300mA A-type B-36 A9L15588 iPF 40 4P C-2 A9L16680 iPRD 8 4P C-5
A9D69625 iDPN N Vigi 25A B 300mA A-type B-36 A9L15590 iPF 40r 4P C-2 A9L16681 C65-340 C-5
A9D69632 iDPN N Vigi 32A B 300mA A-type B-36 A9L15592 iPF 20 2P C-2 A9L16682 C63-460 C-5
A9D69640 iDPN N Vigi 40A B 300mA A-type B-36 A9L15593 iPF 20 4P C-2 A9L16684 C40-460 C-5
A9D02610 iDPN N Vigi 10A C 10mA A-type B-36 A9L15595 iPF 8 2P C-2 A9L16686 C20-460 C-5
A9D02616 iDPN N Vigi 16A C 10mA A-type B-36 A9L15596 iPF 8 4P C-2 A9L16688 C8-460 C-5
A9D08610 iDPN N Vigi 10A B 10mA A-type B-36 A9L15597 iPF 20 3P C-2 A9L16691 C neutral C-5
A9D08616 iDPN N Vigi 16A B 10mA A-type B-36 A9L15598 iPF 8 3P C-2 A9L16292 Quick PRD 40r KA 1PN C-8
A9A27049 Padlock (set of 10/bag) B-39 A9L15683 iPF 65 1P C-2 A9L16293 Quick PRD 40r KA 3P C-8
A9D64806 iC60N RCBO 6A+N 30MA C B-39 A9L15684 iPF 65 1P+N C-2 A9L16294 Quick PRD 40r KA 3PN C-8
A9D64810 iC60N RCBO 10A+N 30MA C B-39 A9L15685 iPF 65r 3P+N C-2 A9L16295 Quick PRD 20r KA 1PN C-8

Acti 9 | Catalogue 2014 15


Index

Reference Description Page Reference Description Page Reference Description Page


A9L16296 Quick PRD 20r KA 3P C-8 A9A26897 IOF+SD 24 AUXILLIARY CONTACT E-2 A9XAH557 57 MODULES OF 18MM , 3(AUX+N+1P) E-21
A9L16297 Quick PRD 20r KA 3PN C-8 A9A26929 iSD Auxiliary contact E-2 A9XAH657 3(AUX+1P) E-21
A9L16298 Quick PRD 8r KA 1PN C-8 A9C18195 iMDU controller 24/48V E-3 A9XPE110 A9 Comb-busbar End-piece 1P set of 10 E-21
A9L16299 Quick PRD 8r KA 3P C-8 GVP01 LASER SQUARE TOOL E-10 A9XPE210 A9 Comb-busbar End-piece 2P set of 10 E-21
A9L16300 Quick PRD 8r KA 3PN C-8 A9A26970 Acti9 10x Padlocking device iC60 iID E-10 A9XPE310 A9 Comb-busbar End-piece 3P set of 10 E-21
A9L16310 Cartridge C40-350 C-8 A9A27003 Acti9 Plug-in base 18mm iC60 iID E-10 A9XPE410 A9 Comb-busbar End-piece 4P set of 10 E-21
A9L16311 Cartridge C20-350 C-8 A9A27005 Acti9 Rotary Handle black iC60 iID E-10 4000 MULTICLIP 80 A SPLITTER BLOCK E-24
ROTARY HANDLE EXTENDED STAND-
A9L16312 Cartridge C8-350 C-8 A9A27006 Acti9 Rotary Handle red iC60 iID E-10 19088 E-26
ARD BLACK
A9L16313 Cartridge C neutral-350 C-8 A9A27008 Acti9 Mechanism for rotary handle iC60 iID E-10 19089 EXTENDED SAFETY E-26
A9L16619 AUXILLIARY 3A 415V C-11 A9A26975 Acti9 2x Terminal shield 18mm iC60 E-11 19090 PADLOCKING DEVICE E-26
A9L16617 Quick PF 10 KA 1PN C-11 A9A26976 Acti9 2x Terminal shield 36mm iC60 iID E-11 19092 DIRECT SAFETY STANDARD BLACK E-26
SCREW ON CONNECTION FOR RING
A9L16618 Quick PF 10 KA 3PN C-11 A9A26981 Acti9 20x Screw shield iC60 iID E-11 19093 E-26
TERMINAL
A9L16337 PRC Telecom C-13 A9A26982 Acti9 12x Screw shield Vigi iC60 E-11 19094 Small ring terminal NG125 E-26
A9L16339 PRI Signal C-13 A9A27001 Acti9 10x Interpole barrier iC60 iID E-11 19095 Alu Terminal 70 sqmm NG125 E-26
A9L16434 iPRD 40r - 600VDC 2P C-15 A9A27062 Acti9 5x Spacer 9mm iC60 iID iCT E-11 19099 WHITE TOGGLE E-26
A9L16436 iPRD 40r - 1000VDC 2P C-15 19091 SET OF 4 DISTRIB.TERMINAL 3X16 E-12 19097 Direct safety Standard REd NG125 E-26
A9L16690 C NEUTRAL PV C-15 19096 Multi cable terminal NG125 pack of 3 E-12 19074 RCD Terminal shield 63A 2P NG125 E-27
A9L16692 C40-1000PV C-15 27060 ALU Cable Connector For C E-12 19075 RCD Terminal shield 63A 3P NG125 E-27
A9L16683 C40-600PV C-15 26970 SET 2 LOCKING SLIDE E-15 19076 RCD Terminal shield 63A 4P NG125 E-27
A9S60120 iSW 1P 20A 250V D-3 26997 PLUG IN BASE 1 E-15 19077 RCD Terminal shield 63A 3P Adjustable E-27
A9S60132 iSW 1P 32A 250V D-3 26996 DBLE ISOLAT.BACK PLATE C6 E-15 19078 set 2 terminal shields 4p E-27
A9S60220 iSW 2P 20A 380/415V D-3 27046 FIX PART ROTARY HANDLE E-15 19080 SET 2 TERMINAL SHIELDS /NG125 1P E-27
A9S60232 iSW 2P 32A 380/415V D-3 27047 DRAWOUT EXTENDED ROTARY HANDLE E-15 19081 SET 2 TERMINAL SHIELDS /NG125 2P E-27
A9S60320 iSW 3P 20A 380/415V D-3 27048 FIX EXTENDED ROTARY HANDLE E-15 19082 SET 2 TERMINAL SHIELDS /NG125 3P E-27
A9S60332 iSW 3P 32A 380/415V D-3 27145 SET 4 LOCKING SLIDE NC100/C120 E-15 19084 SET 2 TERMINAL SHIELDS /NG125 1P E-27
A9S60420 iSW 4P 20A 380/415V D-3 18526 SET OF 2 TERMINAL SHIELDS /C120 E-16 19083 10 TERM.SCREW SHIELDS NG125 1P E-27
A9S60432 iSW 4P 32A 380/415V D-3 18527 SET 8 TERMIN.SCREW SHIELDS /C120 E-16 19085 10 TERM.SCREW SHIELDS NG125 2P E-27
15111 SET 10 REMOV. NEON BULB 230V D-4 26975 SET 2 TERMINAL SHIELDS /C E-16 19086 10 TERM.SCREW SHIELDS NG125 3P E-27
15112 SET 10 REMOV. INCAND. BULB 12V D-4 26976 set 2 terminal shields 36 E-16 19087 10 TERM.SCREW SHIELDS NG125 4P E-27
15113 SET 10 REMOV. INCAND. BULB 24V D-4 26981 SET 2 TERM.SCREW SHIELDS E-16 14811 1P COMB BUSBAR 27M SPACING E-28
15114 SET 10 REMOV. INCAND. BULB 48V D-4 27001 SET 10 INTERPOLE BARRIER E-16 14812 2P COMB BUSBAR 27MM SPACING E-28
A9A15096 OF iSW D-4 A9N27062 SPACER E-16 14813 3p COMB BUSBAR 27MM SPACING E-28
A9S61120 iSW 1P 20A 230V red light D-4 17400 CONNECTION KIT FOR RING TERMINALS E-17 14814 4P COMB BUSBAR 27MM SPACING E-28
A9S61132 iSW 1P 32A 250V red light D-4 18528 SET 2 REAR CONNEC. + TERM.SHEILD E-17 14885 4 INSULATED CONNECTORS E-28
A9S61220 iSW 2P 20A 230V red light D-4 A9XPM112 A9 Comb-busbar 1P , 12 modules of 18mm E-18 10405 End cap -4P, pack of 10 E-29
COMB BUSBAR 12 MODULES C60
A9S61232 iSW 2P 32A 380V red light D-4 A9XPM212 A9 Comb-busbar 2P, 12 modules of 18mm E-18 10545 E-29
CLARIO
COMB BUSBAR 48 MODULES C60
A9S66140 iSW 1P 40A 250V D-6 A9XPM312 A9 Comb-busbar 3P , 12 modules of 18mm E-18 10546 E-29
CLARIO left
COMB BUSBAR 48 MODULES C60
A9S66163 iSW 1P 63A 250V D-6 A9XPM412 A9 Comb-busbar 4P . 12 modules of 18mm E-18 10547 E-29
CLARIO RIGHT
A9 Comb-busbar 3(N+P) , 12 mod. of
A9S66191 iSW 1P 100A 250V D-6 A9XPM512 E-18 19512 COMB BUSBAR PH AND N 18POLES E-29
18 mm
A9S66192 iSW 1P 125A 250V D-6 A9XPCM04 CONNECTORS MONOCONNECT E-19 19516 COMB BUSBAR PH AND N 18POLES E-29
A9S66240 iSW 2P 40A 380/415V D-6 A9XPT920 A9 Comb-busbar Tooth cover E-19 21094 40 END COVERS/COMB BUSBAR E-29
40 END COVERS/COMB BUSBAR 3P
A9S66263 iSW 2P 63A 380/415V D-6 A9XAH157 A9 Comb-busbar Aux+1P E-20 21095 E-29
AND N
A9S66291 iSW 2P 100A 380/415V D-6 A9XAH257 A9 Comb-busbar Aux+2P E-20 21096 12 TOOTH-CAPS 3POLES E-29
A9S66292 iSW 2P 125A 380/415V D-6 A9XAH357 A9 Comb-busbar Aux+3P E-20 21098 4 CONNECTORS 25MM2 E-29
A9S66340 iSW 3P 40A 415V D-6 A9XAH457 A9 Comb-busbar Aux+4P E-20 21501 COMB BUSBAR PH AND N 12POLES E-29
A9S66363 iSW 3P 63A 380/415V D-6 A9XPH106 1P 6 MODULES OF 18MM E-20 21503 comb busbar ph and n 24po E-29
A9S66391 iSW 3P 100A 380/415V D-6 A9XPH112 A9 Comb-busbar 1P , 12 modules of 18mm E-20 21505 COMB BUSBAR E-29
A9S66392 iSW 3P 125A 415V D-6 A9XPH124 A9 Comb-busbar 1P , 24 modules of 18mm E-20 21507 COMB BUSBAR 3P AND N 24POLES E-29
A9S66440 iSW 4P 40A 380/415V D-6 A9XPH157 A9 Comb-busbar 1P , 57 modules of 18mm E-20 21089 COMB BUSBAR ALONE 1P+N E-29
A9S66463 iSW 4P 63A 380/415V D-6 A9XPH212 A9 Comb-busbar 2P ,12 modules of 18mm E-20 21093 3P+N E-29
COMB BUSBAR WITH 9MM AUXILLIARIES
A9S66491 iSW 4P 100A 380/415V D-6 A9XPH224 A9 Comb-busbar 2P , 24 modules of 18mm E-20 A9N21035 E-29
56 (18MM MODULES) 1P+N
A9S66492 iSW 4P 125A 380/415V D-6 A9XPH257 A9 Comb-busbar 2P , 57 modules of 18mm E-20 A9N21036 3P+N E-29
COMB BUSBAR DPN VIGI 1P+N 56 (18MM
A9S66792 3P+N 125A 415VAC D-6 A9XPH312 A9 Comb-busbar 3P ,12 modules of 18mm E-20 A9N21037 E-29
MODULES)
18889 NG125NA 3P 63A D-8 A9XPH324 A9 Comb-busbar 3P , 24 modules of 18mm E-20 A9N21038 3P+N E-29
18890 NG125NA 3P 80A D-8 A9XPH357 A9 Comb-busbar 3P , 57 modules of 18mm E-20 A9N21039 SET 20 SIDE PLATES 1P+N E-29
18891 NG125NA 3P 100A D-8 A9XPH412 A9 Comb-busbar 4P, 12 modules of 18mm E-20 A9N21040 3P+N E-29
18892 NG125NA 3P 125A D-8 A9XPH424 A9 Comb-busbar 4P , 24 modules of 18mm E-20 A9N21041 SET OF 10 PHASE CONNECTORS GREY E-29
SET OF 10 NEUTRAL CONNECTORS
18893 NG125NA 3P AND N 63A D-8 A9XPH457 A9 Comb-busbar 4P , 57 modules of 18mm E-20 A9N21042 E-29
BLUE
SET OF 10 TOOTH COVER (1* 18 MM
18894 NG125NA 3P AND N 80A D-8 A9XPH512 A9 Comb-busbar 3(N+P) 12 mod. Of 18mm E-20 A9N21050 E-29
MODULE)
18895 NG125NA 3P AND N 100A D-8 A9XPH518 18 MODULES OF 18MM E-20 21089 Comb busbar 1P and neutra E-29
18896 NG125NA 3P AND N 125A D-8 A9XPH524 A9 Comb-busbar 3(N+P), 24 mod. Of 18 mm E-20 21093 Comb busbar 3P and neutra E-29
OPEN CLOSE AUXILLIARY CONTACT
27053 SET 8 SCREW CONNECTIONS E-2 A9XPH557 A9 Comb-busbar 3(N+P), 57 mod.,of 18mm E-20 A9N26923 E-31
OF.S FOR ID

16 Acti 9 | Catalogue 2014


Index

Reference Description Page Reference Description Page Reference Description Page


Reflex iC60H Ti24 16 A 3P curve C inte-
A9N26924 OF E-31 A9C70124 WITH TI24 INTERFACE F-19 A9C65316 G-4
grated control MCB
Reflex iC60H Ti24 25 A 3P curve C inte-
A9N26927 iOF Auxiliary contact E-31 A9C70132 ARA IC60 1P,1P+N,2P F-24 A9C65325 G-4
grated control MCB
Reflex iC60H Ti24 40 A 3P curve C inte-
A9N26929 AUXILLIARY CONTACT OF/SD+OF E-31 A9C70134 3P,4P F-24 A9C65340 G-4
grated control MCB
Reflex iC60H Ti24 10 A 4P curve C inte-
A9XC2412 5 PIN CONNECTOR E-33 A9C70332 Acti9 Automatic Recloser auxiliary for iID 2P F-24 A9C65410 G-4
grated control MCB
PREFABRICATED CABLE 100 MM 2 Reflex iC60H Ti24 16 A 4P curve C inte-
A9XCAL06 E-33 A9C70334 Acti9 Automatic Recloser auxiliary for iID 4P F-24 A9C65416 G-4
CONNECTOR grated control MCB
Reflex iC60H Ti24 25 A 4P curve C inte-
A9XCAM06 PREFABRICATED CABLE 160 MM E-33 A9C70342 2P 1 PROGRAM ONLY F-24 A9C65425 G-4
grated control MCB
Reflex iC60N Ti24 10 A 2P curve B inte- Reflex iC60H Ti24 40 A 4P curve C inte-
A9XCAS06 PREFABRICATED CABLE 870 MM E-33 A9C61210 G-4 A9C65440 G-4
grated control MCB grated control MCB
Reflex iC60N Ti24 16 A 2P curve B inte- Reflex iC60H Ti24 10 A 2P curve D inte-
A9XCATM1 LINK USB E-33 A9C61216 G-4 A9C66210 G-4
grated control MCB grated control MCB
PREFABRICATED CABLE 870 MM 1 Reflex iC60N Ti24 25 A 2P curve B inte- Reflex iC60H Ti24 16 A 2P curve D inte-
A9XCAU06 E-33 A9C61225 G-4 A9C66216 G-4
CONNECTOR grated control MCB grated control MCB
Reflex iC60N Ti24 40 A 2P curve B inte- Reflex iC60H Ti24 25 A 2P curve D inte-
A9XM2B04 MOUNTING KIT DIN RAIL E-33 A9C61240 G-4 A9C66225 G-4
grated control MCB grated control MCB
SPARE PART LOCK FOR MULTICLIP 80 Reflex iC60N Ti24 63 A 2P curve B inte- Reflex iC60H Ti24 10 A 3P curve D inte-
A9XMLA02 E-33 A9C61263 G-4 A9C66310 G-4
A (2 CLIPS) grated control MCB grated control MCB
Reflex iC60N Ti24 10 A 3P curve B inte- Reflex iC60H Ti24 16 A 3P curve D inte-
A9XMSB11 ACTI 9 SMARTLINK E-33 A9C61310 G-4 A9C66316 G-4
grated control MCB grated control MCB
Reflex iC60N Ti24 16 A 3P curve B inte- Reflex iC60H Ti24 25 A 3P curve D inte-
A9C15924 IACT24 E-34 A9C61316 G-4 A9C66325 G-4
grated control MCB grated control MCB
Reflex iC60N Ti24 25 A 3P curve B inte- Reflex iC60H Ti24 10 A 4P curve D inte-
A9C15424 IATL24 E-34 A9C61325 G-4 A9C66410 G-4
grated control MCB grated control MCB
Reflex iC60N Ti24 40 A 3P curve B inte- Reflex iC60H Ti24 16 A 4P curve D inte-
A9A26897 IOF+SD24 E-34 A9C61340 G-4 A9C66416 G-4
grated control MCB grated control MCB
Reflex iC60N Ti24 63 A 3P curve B inte- Reflex iC60H Ti24 25 A 4P curve D inte-
A9N26899 PF+SD24 E-34 A9C61363 G-4 A9C66425 G-4
grated control MCB grated control MCB
Reflex iC60N Ti24 10 A 4P curve B inte- Reflex iC60N 10 A 2P curve C integrated
A9A26959 iMN tripping unit 115VAC F-4 A9C61410 G-4 A9C52210 G-4
grated control MCB control MCB
Reflex iC60N Ti24 16 A 4P curve B inte- Reflex iC60N 16 A 2P curve C integrated
A9A26960 iMN tripping unit 220-240VAC F-4 A9C61416 G-4 A9C52216 G-4
grated control MCB control MCB
Reflex iC60N Ti24 25 A 4P curve B inte- Reflex iC60N 25 A 2P curve C integrated
A9A26961 iMN tripping unit 48VAC F-4 A9C61425 G-4 A9C52225 G-4
grated control MCB control MCB
Reflex iC60N Ti24 40 A 4P curve B inte- Reflex iC60N 40 A 2P curve C integrated
A9A26963 iMNs tripping unit 220-240VAC F-4 A9C61440 G-4 A9C52240 G-4
grated control MCB control MCB
Reflex iC60N Ti24 63 A 4P curve B inte- Reflex iC60N 63 A 2P curve C integrated
A9A26969 iMNx tripping unit 220-240VAC F-4 A9C61463 G-4 A9C52263 G-4
grated control MCB control MCB
Reflex iC60N Ti24 10 A 2P curve C inte- Reflex iC60N 10 A 3P curve C integrated
A9A26971 iMNx tripping unit 380-415VAC F-4 A9C62210 G-4 A9C52310 G-4
grated control MCB control MCB
Reflex iC60N Ti24 16 A 2P curve C inte- Reflex iC60N 16 A 3P curve C integrated
A9A26476 iMX tripping unit 100-415VAC F-5 A9C62216 G-4 A9C52316 G-4
grated control MCB control MCB
Reflex iC60N Ti24 25 A 2P curve C inte- Reflex iC60N 25 A 3P curve C integrated
A9A26477 iMX tripping unit 48VAC F-5 A9C62225 G-4 A9C52325 G-4
grated control MCB control MCB
Reflex iC60N Ti24 40 A 2P curve C inte- Reflex iC60N 40 A 3P curve C integrated
A9A26478 iMX tripping unit 12-24VAC F-5 A9C62240 G-4 A9C52340 G-4
grated control MCB control MCB
Reflex iC60N Ti24 63 A 2P curve C inte- Reflex iC60N 63 A 3P curve C integrated
A9A26500 IMSU OVERVOLTAGE RELEASE F-5 A9C62263 G-4 A9C52363 G-4
grated control MCB control MCB
Reflex iC60N Ti24 10 A 3P curve C inte- Reflex iC60N 10 A 4P curve C integrated
A9A26946 iMX+OF tripping unit 100-415VAC F-5 A9C62310 G-4 A9C52410 G-4
grated control MCB control MCB
Reflex iC60N Ti24 16 A 3P curve C inte- Reflex iC60N 16 A 4P curve C integrated
A9A26947 iMX+OF tripping unit 48VAC F-5 A9C62316 G-4 A9C52416 G-4
grated control MCB control MCB
Reflex iC60N Ti24 25 A 3P curve C inte- Reflex iC60N 25 A 4P curve C integrated
A9A26948 iMX+OF tripping unit 12-24VAC F-5 A9C62325 G-4 A9C52425 G-4
grated control MCB control MCB
Reflex iC60N Ti24 40 A 3P curve C inte- Reflex iC60N 40 A 4P curve C integrated
A9A26855 ISD FAULT INDICATING CONTACT F-6 A9C62340 G-4 A9C52440 G-4
grated control MCB control MCB
IOF OPEN CLOSE AUXILLIARY CONTACT Reflex iC60N Ti24 63 A 3P curve C inte- Reflex iC60N 63 A 4P curve C integrated
A9A26869 F-6 A9C62363 G-4 A9C52463 G-4
IC60 ILD DOUBLE TERMINAL grated control MCB control MCB
IOF OPEN CLOSE AUXILLIARY CONTACT Reflex iC60N Ti24 10 A 4P curve C inte-
A9A26924 F-6 A9C62410 G-4 A9C20132 iCT25A 2NO 24/Vac 50HZ contactor G-12
IC60 ILD IDPN VIGI ISWNA RCA ARA grated control MCB
Reflex iC60N Ti24 16 A 4P curve C inte-
A9A26927 iOF/SD+OF Auxiliary contact F-6 A9C62416 G-4 A9C20134 iCT25A 4NO 24/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 25 A 4P curve C inte-
A9N26959 IMN UNDERVOLTAGE RELEASE F-10 A9C62425 G-4 A9C20137 iCT25A 4NC 24/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 40 A 4P curve C inte-
A9N26960 IMN UNDERVOLTAGE RELEASE F-10 A9C62440 G-4 A9C20162 iCT63A 2NO 24/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 63 A 4P curve C inte-
A9N26961 IMN UNDERVOLTAGE RELEASE F-10 A9C62463 G-4 A9C20164 iCT63A 4NO 24/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 10 A 2P curve D inte-
A9N26963 IMNS F-10 A9C63210 G-4 A9C20167 iCT63A 4NC 24/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 16 A 2P curve D inte-
A9N26969 IMNX F-10 A9C63216 G-4 A9C20232 iCT25A 2NO 48/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 25 A 2P curve D inte-
A9N26971 IMNX F-10 A9C63225 G-4 A9C20531 iCT25A 1NO 220/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 10 A 3P curve D inte-
A9N26476 SHUNT RELEASE IMX F-11 A9C63310 G-4 A9C20532 iCT25A 2NO 220/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 16 A 3P curve D inte-
A9N26477 SHUNT RELEASE IMX F-11 A9C63316 G-4 A9C20536 iCT25A 2NC 220/Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 25 A 3P curve D inte-
A9N26478 SHUNT RELEASE IMX F-11 A9C63325 G-4 A9C22711 iCT16A 1NO 230/240Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 10 A 4P curve D inte-
A9N26500 IMSU OVERVOLTAGE RELEASE F-11 A9C63410 G-4 A9C22712 iCT16A 2NO 230/240Vac 50HZ contactor G-12
grated control MCB
Reflex iC60N Ti24 16 A 4P curve D inte- iCT16A 1NO 1NC 230/240Vac 50HZ
A9N26946 IMX+OF SHUNT RELEASE F-11 A9C63416 G-4 A9C22715 G-12
grated control MCB contactor
Reflex iC60N Ti24 25 A 4P curve D inte-
A9N26947 IMX+OF SHUNT RELEASE F-11 A9C63425 G-4 A9C22722 iCT20A 2NO 230/240Vac 50HZ contactor G-12
grated control MCB
Reflex iC60H Ti24 10 A 2P curve B inte-
A9N26948 IMX+OF SHUNT RELEASE F-11 A9C64210 G-4 A9C22813 iCT16A 3NO 220/240Vac 50HZ contactor G-12
grated control MCB
Reflex iC60H Ti24 16 A 2P curve B inte-
19061 MNX for NG125 230V AC F-15 A9C64216 G-4 A9C22814 iCT16A 4NO 220/240Vac 50HZ contactor G-12
grated control MCB
Reflex iC60H Ti24 25 A 2P curve B inte- iCT16A 2NO 2NC 220/240Vac 50HZ
19063 MX AND OF 12VCC FOR NG125 F-15 A9C64225 G-4 A9C22818 G-12
grated control MCB contactor
Reflex iC60H Ti24 40 A 2P curve B inte-
19064 MX+OF 220/415VAC FOR NG12 F-15 A9C64240 G-4 A9C22824 iCT20A 4NO 220/240Vac 50HZ contactor G-12
grated control MCB
Reflex iC60H Ti24 10 A 3P curve B inte- iCT25A 3NO 220/240Vac 50HZ M.O.
19065 MX AND OF 48/130VAC FOR NG125 F-15 A9C64310 G-4 A9C21833 G-13
grated control MCB contactor
Reflex iC60H Ti24 16 A 3P curve B inte- iCT25A 4NO 220/240Vac 50HZ M.O.
19066 MX+OF 24VAC/DC FOR NG125 F-15 A9C64316 G-4 A9C21834 G-13
grated control MCB contactor
Reflex iC60H Ti24 25 A 3P curve B inte- iCT40A 2NO 220/240Vac 50HZ M.O.
19067 MN 230VAC FOR NG125 F-15 A9C64325 G-4 A9C21842 G-13
grated control MCB contactor
Reflex iC60H Ti24 40 A 3P curve B inte- iCT40A 3NO 220/240Vac 50HZ M.O.
19069 MN 48VAC FOR NG125 F-15 A9C64340 G-4 A9C21843 G-13
grated control MCB contactor
Reflex iC60H Ti24 10 A 4P curve B inte- iCT40A 4NO 220/240Vac 50HZ M.O.
19070 UNDERVOLTAGE RELEASE MN F-15 A9C64410 G-4 A9C21844 G-13
grated control MCB contactor
Reflex iC60H Ti24 16 A 4P curve B inte- iCT63A 2NO 220/240Vac 50HZ M.O.
19071 OF+OF FOR NG125 F-16 A9C64416 G-4 A9C21862 G-13
grated control MCB contactor
Reflex iC60H Ti24 25 A 4P curve B inte- iCT63A 4NO 220/240Vac 50HZ M.O.
19072 OF+SD FOR NG125 F-16 A9C64425 G-4 A9C21864 G-13
grated control MCB contactor
Reflex iC60H Ti24 40 A 4P curve B inte-
19058 SDV NO FOR VIGI NG125 F-17 A9C64440 G-4 A9C23512 iCT16A 2NO 220/Vac 50HZ M.O. contactor G-13
grated control MCB
Reflex iC60H Ti24 10 A 2P curve C inte- iCT16A 1NO 1NC 220/Vac 50HZ M.O.
19059 SDV NF FOR VIGI NG125 F-17 A9C65210 G-4 A9C23515 G-13
grated control MCB contactor
Reflex iC60H Ti24 16 A 2P curve C inte- iCT16A 2NO 230/240Vac 50HZ M.O.
19060 MXV FOR VIGI NG125 F-17 A9C65216 G-4 A9C23712 G-13
grated control MCB contactor
RCA REMOTE CONTROLS WITHOUT TI24 Reflex iC60H Ti24 25 A 2P curve C inte- iCT16A 1NO 1NC 230/240Vac 50HZ M.O.
A9C70112 F-19 A9C65225 G-4 A9C23715 G-13
INTERFACE 1P,1P+N,2P grated control MCB contactor
Reflex iC60H Ti24 40 A 2P curve C inte-
A9C70122 WITH TI24 INTERFACE F-19 A9C65240 G-4 A9C20632 iCT25A 2NO 220/240Vac 60HZ contactor G-14
grated control MCB
RCA REMOTE CONTROLS WITHOUT TI24 Reflex iC60H Ti24 10 A 3P curve C inte-
A9C70114 F-19 A9C65310 G-4 A9C20633 iCT25A 3NO 220/240Vac 60HZ contactor G-14
INTERFACE 3P 4P grated control MCB

Acti 9 | Catalogue 2014 17


Index

Reference Description Page Reference Description Page Reference Description Page


ISSW LINEAR SWITCH 1 CHANGEROVER G-44
A9C20636 iCT25A 2NC 220/240Vac 60HZ contactor G-14 A9C21144 iCT40A 4NO 24/Vac 50HZ M.O. contactor G-24 A9E18073 3POSITION
A9C20642 iCT40A 2NO 220/240Vac 60HZ contactor G-14 A9C21162 iCT63A 2NO 24/Vac 50HZ M.O. contactor G-24 A9E18074 2 CHANGEOVER SWITCHES G-44
A9C20643 iCT40A 3NO 220/240Vac 60HZ contactor G-14 A9C21164 iCT63A 4NO 24/Vac 50HZ M.O. contactor G-24 A9E15120 ICMB TWO POL WITH ZERO SETTING G-45
A9C20663 iCT63A 3NO 220/240Vac 60HZ contactor G-14 A9C21532 iCT25A 2NO 220/Vac 50HZ M.O. contactor G-24 A9E15121 ICMD 4 WAY G-45
iCT25A 2NO 230/240Vac 50HZ M.O.
A9C22415 iCT16A 1NO 1NC 127/Vac 60HZ contactor G-14 A9C25732 G-24 A9E15122 ICME 2WAY FOR ELECTRONIC CIRCUITS G-45
contactor
iCT16A 1NO 1NC 220/240Vac 60HZ CMV VOLTMETER CHANGE-OVER SW
A9C21442 iCT40A 2NO 127/Vac 60HZ M.O. contactor G-14 A9C22615 G-24 15125 G-46
contactor 7 OUTP
iCT40A 2NO 220/240Vac 60HZ M.O. iTL16A 1NO 12Vac 50-60hz 6Vdc impulse CMA AMPMETER CHANGE-OVER SW
A9C21642 G-14 A9C30011 G-30 15126 G-46
contactor relay 4 OUTPUT
iTL16A 2NO 12Vac 50-60hz 6Vdc impulse
A9C20431 iCT25A 1NO 127/Vac 60HZ contactor G-14 A9C30012 G-30 A9E15123 ICMC 2WAY KEY ACTUATED G-46
relay
iTLI 16A 1NO 1NC 12Vac 50-60hz 6Vdc
A9C20432 iCT25A 2NO 127/Vac 60HZ contactor G-14 A9C30015 G-30 A9E18320 iIL red 110-230VAC H-2
impulse relay
iTL16A 1NO 24Vac 50-60hz 12Vdc impulse
A9C20433 iCT25A 3NO 127/Vac 60HZ contactor G-14 A9C30111 G-30 A9E18321 iIL green 110-230VAC H-2
relay
iTL16A 2NO 24Vac 50-60hz 12Vdc impulse
A9C20436 iCT25A 2NC 127/Vac 60HZ contactor G-14 A9C30112 G-30 A9E18322 iIL white 110-230VAC H-2
relay
iTL16A 4NO 24Vac 50-60hz 12Vdc impulse
A9C20442 iCT40A 2NO 127/Vac 60HZ contactor G-14 A9C30114 G-30 A9E18323 iIL blue 110-230VAC H-2
relay
iTLI 16A 1NO 1NC 24Vac 50-60hz 12Vdc
A9C20443 iCT40A 3NO 127/Vac 60HZ contactor G-14 A9C30115 G-30 A9E18324 iIL yellow110- 230VAC H-2
impulse relay
iTL16A 1NO 48Vac 24Vdc 50-60HZ impulse
A9C20463 iCT63A 3NO 127/Vac 60HZ contactor G-14 A9C30211 G-30 A9E18325 iIL green/red 110-230VAC H-2
relay
iTL16A 2NO 48Vac 50-60hz 24Vdc impulse
A9C20631 iCT25A 1NO 220/240Vac 60HZ contactor G-14 A9C30212 G-30 A9E18326 iIL flashing red 110-230VAC H-2
relay
iTLI 16A 1NO 1NC 48Vac 50-60hz 24Vdc
A9C15924 iACT24 com indication auxiliary G-17 A9C30215 G-30 A9E18327 iIL 3 phase Red - 230-400 VAC H-2
impulse relay
iTL16A 1NO 130Vac 48Vdc 50-60HZ
A9C15914 iACTs 1NO+1NC indication auxiliary G-18 A9C30311 G-30 A9E18328 iIL double white 110-230VAC H-2
impulse relay
iTL16A 2NO 130Vac 50-60hz 48Vdc
A9C15915 iACTs 1OF indication auxiliary G-18 A9C30312 G-30 A9E18330 iIL red 12-48VAC H-2
impulse relay
iTLI 16A 1NO 1NC 130Vac 50-60hz 48Vdc
A9C15916 iACTs 2NO indication auxiliary G-18 A9C30315 G-30 A9E18331 iIL green 12-48VAC H-2
impulse relay
iTL16A 1NO 230Vac 110Vdc 50-60HZ
A9C15918 iACTp 48…127 Vac coil suppression blocs G-18 A9C30811 G-30 A9E18332 iIL white 12-48VAC H-2
impulse relay
iTL16A 2NO 230Vac 50-60hz 110Vdc
A9C15919 iACTp 12…48 Vac coil suppression blocs G-18 A9C30812 G-30 A9E18333 iIL blue 12-48VAC H-2
impulse relay
iTL16A 4NO 230Vac 50-60hz 110Vdc
A9C15920 iACTp 220…240 Vac coil suppression blocs G-18 A9C30814 G-30 A9E18334 iIL yellow 12-48VAC H-2
impulse relay
iACTc 230 Vac double control inputs iTLI 16A 1NO 1NC 230Vac 50-60hz 110Vdc
A9C18308 G-18 A9C30815 G-30 A9E18335 iIL double green-red 12-48VAC H-2
auxiliary impulse relay
iTL 32A 1NO 230Vac 50-60hz 110Vdc
A9C18309 iACTc 24 Vac double control inputs auxiliary G-18 A9C30831 G-30 15320 SO bell 230v H-3
impulse relay
iETL16A 1CO 1NO 12Vac 50-60hz 6Vdc
A9A15921 Acti9 20x Screw shield iCT 3-4P 16-25A G-21 A9C32016 G-30 15321 BELL 8/12V H-3
extension for impulse relay
iETL16A 1CO 1NO 24Vac 50-60hz 12Vdc
A9A15922 Acti9 20x Screw shield iCT 2P 40-63A G-21 A9C32116 G-30 A9A15322 IRO BUZZER 230 V H-3
extension for impulse relay
iETL16A 1CO 1NO 48Vac 50-60hz 24Vdc
A9A15923 Acti9 20x Screw shield iCT 3-4P 40-63A G-21 A9C32216 G-30 A9A15323 8-12 V H-3
extension for impulse relay
iETL16A 1CO 1NO 130Vac 50-60hz 48Vdc
A9C15415 Yellow clips accessories (set of 10 clips) G-21 A9C32316 G-30 15228 TERMINAL SHIELD 4 (9MM MODULES) H-4
extension for impulse relay
iETL16A 1CO 1NO 230Vac 50-60hz 110Vdc
A9C20731 iCT25A 1NO 230/240Vac 50HZ contactor G-23 A9C32816 G-30 15229 TERMINAL SHIELD 6 (9MM MODULES) H-4
extension for impulse relay
iETL 32A 1CO 1NO 230Vac 50-60hz 110Vdc
A9C24732 iCT25A 2NO 230/240Vac 50HZ contactor G-23 A9C32836 G-30 15230 TERMINAL SHIELD 10 (9MM MODULES) H-4
extension for impulse relay
iTLs 16A 1NO 24Vac 50-60hz 12Vdc ITR TRANSFORMER 8-12V SECONDARY
A9C20736 iCT25A 2NC 230/240Vac 50HZ contactor G-23 A9C32111 G-31 A9A15212 H-4
impulse relay with remote indication OFF LOAD 13-18
iTLs 16A 1NO 48Vac 50-60hz 24Vdc ITR TRANSFORMER 8-12V SECONDARY
A9C20833 iCT25A 3NO 220/240Vac 50HZ contactor G-23 A9C32211 G-31 A9A15213 H-4
impulse relay with remote indication OFF LOAD 12-16
iTLs 16A 1NO 230Vac 50-60hz 110Vdc ITR TRANSFORMER 8-12VSECONDARY
A9C24834 iCT25A 4NO 220/240Vac 50HZ contactor G-23 A9C32811 G-31 A9A15214 H-4
impulse relay with remote indication OFF LOAD 12V
iTLc 16A 1NO 24Vac 50-60HZ impulse relay ITR TRANSFORMER 12-24V SECONDARY
A9C20837 iCT25A 4NC 220/240Vac 50HZ contactor G-23 A9C33111 G-31 A9A15215 H-4
with centralized control OFF LOAD 16-32
iCT25A 2NO 2NC 220/240Vac 50HZ iTLc 16A 1NO 48Vac 50-60HZ impulse relay ITR TRANSFORMER 8-12V SECONDARY
A9C20838 G-23 A9C33211 G-31 A9A15216 H-4
contactor with centralized control OFF LOAD 13-18
ITR TRANSFORMER 12-24V SECONDARY
A9C20842 iCT40A 2NO 220/240Vac 50HZ contactor G-23 A9C33811 230-240 G-31 A9A15218 H-4
OFF LOAD 14-28
iTLm 16A 1NO 230Vac 50-60HZ impulse ITR TRANSFORMER 12-24V SECONDARY
A9C20843 iCT40A 3NO 220/240Vac 50HZ contactor G-23 A9C34811 G-31 A9A15219 H-4
relay with latched control OFF LOAD 14-28
iATLc 24-240 Vac centralized control auxil- ITR TRANSFORMER 12-24V SECONDARY
A9C20844 iCT40A 4NO 220/240Vac 50HZ contactor G-23 A9C15404 G-34 A9A15220 H-4
iary for impulse relay OFF LOAD 14-28
iATLs 24-240 Vac/Vdc indication auxiliary for ITR TRANSFORMER 12-24V SECONDARY
A9C20847 iCT40A 4NC 220/240Vac 50HZ contactor G-23 A9C15405 G-34 A9A15222 H-4
impulse relay OFF LOAD 14-28
iATLc+s 24-240 Vac centralized control -
A9C20862 iCT63A 2NO 220/240Vac 50HZ contactor G-23 A9C15409 G-34 15483 IC2000P+ I-3
indication auxiliary for impulse relay
iATLc+c 24-240 Vac multi-level centralized
A9C20863 iCT63A 3NO 220/240Vac 50HZ contactor G-23 A9C15410 G-34 15482 ic 100 and wall mounted c I-3
control auxiliary for impulse relay
iATL4 230Vac 50-60hz step by step control
A9C20864 iCT63A 4NO 220/240Vac 50HZ contactor G-23 A9C15412 G-35 CCT15284 IC 2000+built-in analog sensor I-3
auxiliary for impulse relay
iATLz 130-240 Vac control by illuminated
A9C20867 iCT63A 4NC 220/240Vac 50HZ contactor G-23 A9C15413 G-35 CCT15368 IC200 WITH WALL MOUNTED CELL I-3
pushbuttons auxiliary for impulse relay
iCT63A 2NO 2NC 220/240Vac 50HZ iATLm 12-240 Vac 6-110 Vdc latched control
A9C20868 G-23 A9C15414 G-35 15281 IC 200 CELL I-3
contactor auxiliary for impulse relay
iCT63A 3NO 1NC 220/240Vac 50HZ
A9C20869 G-23 A9C15419 iATEt 24…240 Vac time delay auxiliary G-35 CCT15223 IC ASTRO 1C LANGUAGE.. I-4
contactor
A9C20882 iCT100A 2NO 220/240Vac 50HZ contactor G-23 A9C15424 iATL24 com indication auxiliary G-36 CCT15224 IC ASTRO 1C LANGUAGE.. I-4
A9C20884 iCT100A 4NO 220/240Vac 50HZ contactor G-23 A9C15032 TL+ 1PN 16A 230Vac G-39 CCT15243 IC Astro 2C v.1 I-4
A9C22015 iCT16A 1NO 1NC 12/Vac 50HZ contactor G-23 A9C15030 CT+ 1PN 20A 230Vac G-41 CCT15244 IC Astro 2C v.2 I-4
A9C22111 iCT16A 1NO 24/Vac 50HZ contactor G-23 A9C15031 CT+ HC 1PN 20A 230Vac G-41 CCT15250 IC 100k+ 1C v.1 I-4
A9C22112 iCT16A 2NO 24/Vac 50HZ contactor G-23 A9E18030 iPB grey 1O G-43 CCT15251 IC 100k+ 1C v.2 I-4
A9C22114 iCT16A 4NO 24/Vac 50HZ contactor G-23 A9E18031 iPB red 1O G-43 CCT15252 IC 100k+ 2C v.1 I-4
A9C22115 iCT16A 1NO 1NC 24/Vac 50HZ contactor G-23 A9E18032 iPB grey 1F G-43 CCT15253 IC 100k+ 2C v.2 I-4
A9C22211 iCT16A 1NO 48/Vac 50HZ contactor G-23 A9E18033 iPB grey 1O+1F G-43 CCT15490 IC 100kp+ 1C v.1 I-4
A9C22212 iCT16A 2NO 48/Vac 50HZ contactor G-23 A9E18034 iPB green+red G-43 CCT15491 IC 100kp+ 1C v.2 I-4
A9C22511 iCT16A 1NO 220/Vac 50HZ contactor G-23 A9E18035 iPB grey+grey G-43 CCT15492 IC 100kp+ 2C v.1 I-4
A9C22512 iCT16A 2NO 220/Vac 50HZ contactor G-23 A9E18036 iPB grey+green light G-43 CCT15493 IC 100kp+ 2C v.2 I-4
A9C22515 iCT16A 1NO 1NC 220/Vac 50HZ contactor G-23 A9E18037 iPB grey+red light G-43 CCT15268 wall mounted cell I-5
A9C22011 iCT16A 1NO 12/Vac 50HZ contactor G-23 A9E18038 iPB grey+green ELVlamp G-43 CCT15860 programming kit for PC I-5
MULTI-FUNCTIONAL TIME SWITCH 4
A9C22012 iCT16A 2NO 12/Vac 50HZ contactor G-23 A9E18039 iPB grey+red ELV lamp G-43 15270 I-13
CHANNELS
ISSW LINEAR SWITCH 1 CHANGEROVER G-44
A9C21132 iCT25A 2NO 24/Vac 50HZ M.O. contactor G-24 A9E18070 15280 MEMORY CARD FOR PROGRAM COPY I-13
2POSITION
A9C21134 iCT25A 4NO 24/Vac 50HZ M.O. contactor G-24 A9E18071 2 CHANGEOVER G-44 15331 IH 18mm 7d arm I-13
A9C21142 iCT40A 2NO 24/Vac 50HZ M.O. contactor G-24 A9E18072 1NO+1NC G-44 15335 IH 18mm 24h srm I-13

18 Acti 9 | Catalogue 2014


Index

Reference Description Page


15336 IH 18mm 24h arm I-13
15366 IH 45mm 2C 24h+7d arm I-13
IHP 7D 1C WITH RADIO-CONTROLLED-
15857 I-13
TIME ON
15858 RADIO ANTENNA FOR IHP 15857 I-13
CCT15338 IH 45mm 60m srm I-13
CCT15365 IH 45mm 24h arm I-13
CCT15367 IH 7j arm I-13
CCT15850 IHP 45mm 1C 7d I-13
CCT15851 IHP+ 45mm 1C 7d I-13
CCT15852 IHP 45mm 2C 7d I-13
CCT15853 IHP+ 45mm 2C 7d I-13
CCT15854 IHP 1C 18mm I-13
CCT16364 IH 24h srm I-13
15337 IH 45mm 2C 24h arm I-13
CCT15837 IHP+ 1C 18mm I-13
15341 SET 20 RIDERS FOR TIME SW I-18
15359 TERMINAL SHIELDS FOR TIME I-18
15363 MIN I-25
CCT15232 MINs I-25
CCT15233 MINp I-26
CCT15234 MINt I-26
CCTDD20001 STD 400W RL/RC I-29
CCTDD20002 STD 400W RL/RC - 4 dig. inputs I-29
CCTDD20003 STD 1000W RL I-29
CCTDD20004 STD 1000W RL - 4 dig. inputs I-29
CCTDD20011 SCU 1-10V (controller) I-30
CCTDD20012 SCU 1-10V (controller) - 4 dig. inputs I-30
CCT15840 TH7 - Thermostat DIN I-34
CCT15841 TH4 - Thermostat DIN I-34
15833 THP1 - Thermostat DIN I-35
15834 THP2 - Thermostat DIN I-35
CCT15845 Floor temperature probe with 1.5 m cable I-36
CCT15846 Ambient temperature probe I-36
15835 sensor I-37
15836 Adjustable ambient sensor I-37
16358 SPARE PARTS BATTERY FOR THP 1/2 I-37
CCT15847 Outside temperature probe with 2 m cable I-37
CCT15848 Collar temperature probe with 1.5 m cable I-37
A9E16065 RTA TIME RELAY DELAY I-44
A9E16066 RTB TIME RELAY DELAY I-44
A9E16067 RTC TIME RELAY DELAY I-44
A9E16068 RTH TIME RELAY DELAY I-45
A9E16069 RTL TIME RELAY DELAY I-45
A9E16070 RTMF TIME RELAY DELAY I-45
A9A15393 IRBN LOW LEVEL I-46
A9A15416 IRTBT EXTRA LOW LEVEL I-46
A9E15535 IRLI CHANGEOVER RELAY I-47
A9E15536 IRLI CHANGEOVER RELAY I-47
A9E15537 IRLI CHANGEOVER RELAY I-47
A9E15538 IRLI CHANGEOVER RELAY I-47
A9E15539 IERL EXTENSION FOR RLI I-47
A9E15540 IERL EXTENSION FOR RLI I-47
A9E15541 IERL EXTENSION FOR RLI I-47
A9E15542 IERL EXTENSION FOR RLI I-47
A9E21181 IRCI CURRENT CONTROL I-48
A9E21182 IRCU VOLTAGE CONTROL I-48
A9E21180 IRCP PHASE CONTROL I-49
A9E21183 IRCC COMPRESSOR CONTROL I-49

Acti 9 | Catalogue 2014 19


6 Acti 9 | Catalogue 2014
Protection Principle of catalogue numbers
Circuit protection
Earth leakage protection

iID, iC60, Vigi iC60, Reflex iC60, switches

A9 R 15 2 63
Range Family Code Internal code Poles Code Rating (A) Code
Acti 9 (A9) iID R 0 0 0 00
Vigi iC60 V 1P 1 0.5 70
iC60 F 2P 2 0.75 71
iK60 K 3P 3 1 01
Auxiliaries and accessories A 4P 4 1.6 72
Switches S 1N 5 2 02
Reflex iC60 C 1P+N 6 2.5 73
iC60 RCBO D 3P+N 7 3 03
4 04
6 06
6.3 76
8 08
10 10
12.5 82
13 13
16 16
20 20
25 25
32 32
40 40
50 50
63 63
80 80
100 91
125 92

Comb busbar and comb busbar accessories

A9 X P H 4 12
Range Family Code Type Type of Number of poles Dimensioning
installation
Acti 9 (A9) Comb X Comb busbar 1P 1 Comb busbar Number of 18
busbar mm modules
(approximately)
Fork F Horizontal H
Tooth P 2P 2 Accessories Number of
pieces per cat.
no.
Auxiliarisable A 3P 3
Accessories 4P 4
End-piece E Double terminals D 4P balanced, with neutral 5
Tooth cover T Single terminal M 3P balanced for single-poles 6
Connector C

Acti 9 | Catalogue 2014 7


Protection Choice of circuit protective
Circuit protection
devices

b Circuit breakers can:


v guard against fires that might be caused by a faulty electric circuit (short-circuit,
overload, insulation fault),
v protect people against electric shock in the event of indirect contact.
b The choice of circuit breakers must be optimised to provide absolute protection
while ensuring continuity of service.
b Although circuit breakers are sometimes used as control units, it is recommended
to install separate control devices which are more suitable for frequent switching
operations (switch, contactor, impulse relay).

Choice of protective circuit breakers


This depends on several criteria:
DB123788

b breaking capacity
L1 b max. voltage rating
L2 b planned amperage for the circuit to be protected
L3
b nature and cross section of cables
b ambient temperature (possible derating)
b the loads, which determine the number of poles of the protective circuit breaker
Protection of electrical connections against installed on their power supply circuit and the tripping curve.
magnetic short circuits and thermal overloads
Choice of breaking capacity
b The breaking capacity must be greater than or equal to the prospective short-
circuit current (Isc) upstream of the circuit-breaker (Isc depends on the length and
cross section of the cable and the power of the source).
b However, in the event of use in combination with an upstream circuit-breaker
DB123789

limiting the current, this breaking capacity can possibly be reduced.

Choice of rating
b The rating (In) is chosen above all to protect the electrical connections:
v for cables: it is chosen according to the cross section,
v for Canalis prefabricated busbar trunking: it must be simply less than or equal to
Protection of loads against overloads the rating of the busbar trunking.
b Generally, the rating should be greater than the nominal current of the circuits.
b The rating of the upstream circuit breaker must always be less than or equal to the
sum of the ratings of the downstream circuit breakers.
DB123790

Choice of tripping curve


The tripping curve makes the protection more or less sensitive to:
b the inrush current at power up
b the overload current.

Protection of control devices


E103695

t (s)
Overload
DB123792

protection
(thermal)

7-15

2-4
Short-circuit
protection
Protection for people against indirect contacts in 0.5-1.5
B C D (magnetic).
IT and TN earthing systems 0.01-0.02

1.1-1.5 3-5 5-10 10-14 I / In

Tripping thresholds (x In)


Curves EN 60898 IEC 60947-2
B Between 3 In and 5 In Between 3.2 In and 4.8 In
C Between 5 In and 10 In Between 7 In and 10 In
D or K - Between 10 In and 14 In
MA - 12 In
Z - Between 2.4 In and 3.6 In

b To prevent nuisance tripping, it may be advisable to choose a less sensitive curve,


e.g. change from B to C.

8 Acti 9 | Catalogue 2014


Protection Choice of circuit protective
Circuit protection
devices (cont.)

Continuity of service
b Nuisance tripping can be generated by:
v the inrush current at circuit closure,
v the overload current, and sometimes the harmonic current flowing through the
neutral of three-phase circuits (1).

Solutions
b Choose a circuit breaker with a less sensitive curve: change from B curve to C
curve or from C curve to D curve (2).
b Reduce the number of loads per circuit.
b Energize the circuits in succession, using time delay auxiliaries on the control
devices.
b Under no circumstances may the circuit breaker rating be increased, as the
electrical connections would then no longer be protected.
b Ensure discrimination of the protective devices

Discrimination is the coordination of automatic breaking devices in such a way that a


fault occurring at any point on the network is eliminated by the circuit breaker located
immediately upstream of the fault, and by it alone.
Total discrimination
DB120589

For all values of the fault, from overload to non-resistive short circuit, distribution is
fully discriminating if D2 opens and if D1 remains closed.
Partial discrimination
Discrimination is partial if the above condition is not complied with up to full short-
circuit current, but only up to a lower value. This value is called the discrimination
limit.
In the event of a fault exceeding this value, circuit breakers D1 and D2 open.

(1) In the specific case of three-phase circuits supplying discharge lamps with electronic ballasts,
harmonic currents of the third order and multiples of three are generated. The neutral cable
must be sized to prevent it from overheating. However, the current flowing through the neutral
conductor may become greater than the current of each phase and cause nuisance tripping.
(2) In the case of installations with very long cables in a TN or IT system, it may be necessary to
add an earth leakage protection device to protect human life..

Disconnection
The purpose of disconnection is to separate and isolate a circuit or a device from the
DB123787

rest of the electrical installation in order to ensure the safety of personnel having to
work on the electrical installation for maintenance or repair.
b The circuit breaking must be omnipolar, i.e. the live conductors, including
neutral (1), must be cut off.
b It must be lockable or padlockable in "open" position in order to prevent any
Circuit isolation unintentional reclosing, at least in industrial environments.
b It must be in compliance with a standard ensuring its suitability for isolation.

(1) With the exception of the PEN conductor which should never be cut off.

Motor protection
Protection of motors against risks of overheating due, for example, to an extended
DB123791

overload, rotor blocking or single-phase operation. Given the specific characteristics


of motors:
b overload detection is entrusted to a thermal relay specially designed for their
protection. This relay may possibly provide overload protection for busbar trunking
b in this case short-circuit protection is provided by a circuit breaker without a
Motor protection thermal release (MA type).

Acti 9 | Catalogue 2014 9


Protection Circuit breaker panorama
Circuit protection

Selection guide
Circuit breakers
Type iDPN iDPN N

Standard IEC/EN 60898-1 IEC/EN 60898-1


Number of poles 1P+N 1P+N, 3P, 3P+N
Add-on residual current devices (Vigi) b b
Auxiliaries for remote tripping and indication b b
Electrical characteristics
Curves B, C C, D
Ratings (A) In 1 to 40 1 to 40
Maximum operational voltage (V) Ue AC (50/60 Hz) 230 230/400
max DC – –
Minimum operational voltage (V) Ue AC (50/60 Hz) – –
min DC – –
Insulation voltage (V AC) Ui 440 440
Rated impulse withstand voltage (kV) Uimp 4 4
Limitation class up to 40 A (EN 60898) 3 3
Breaking capacity
AC-Breaking capacity Ue (50/60 Hz)
IEC 60947-2 (kA) Icu 12...60 V – –

12...133 V – –

100...133 V – –

220...240 V 6 10

380...415 V 2 (1) 2 (1)

440 V – –

Ics – –

IEC/EN 60898 (A) Icn 240/415 V 4500 6000


- 230/400 V
DC-Breaking capacity Ue DC
IEC 60947-2 (kA) Icu 12...48 V (1P) – –
72 V (1P) – –
100...133 V (2P) – –
100...133 V (3P) – –
220...250 V (4P) – –
Ics – –
Other characteristics
Suitable for industrial isolation according to IEC/EN 60947-2 – –
Reference temperature IEC/EN 60947-2 – –
Fault tripping indication – –
Positive contact indication b b
Fast closing b b
Degree of protection IP Device only IP20 IP20
Device in modular IP40 IP40
enclosure Insulation class II Insulation class II
For more detail, see page A-2 A-3
Accessories E-29 E-29
Auxiliaries E-31 E-31
Add-on residual current devices (Vigi) B-33 B-33
(1) Breaking capacity under 1 pole with IT isolated neutral system (case of double fault).

10 Acti 9 | Catalogue 2014


Protection Circuit breaker panorama (cont.)
Circuit protection

iK60N iC60N iC60H iC60L

IEC/EN 60898-1 IEC/EN 60947-2, 60898-1 IEC/EN 60947-2, 60898-1 IEC/EN 60947-2, 60898-1
1P, 1P+N 2, 3, 4P 1P, 1P+N 2, 3, 4P 1P, 1P+N 2, 3, 4P 1P 2, 3, 4P
– b b b
– b b b

B, C B, C, D B, C, D B, C, K, Z
1 to 63 0.5 to 63 (1 to 63 in DC) 0.5 to 63 (1 to 63 in DC) 0.5 to 63 (1 to 63 in DC)
230/400 240/415, 440 240/415, 440 240/415, 440
– 250 250 250
– 12 12 12
– 12 12 12
400 500 500 500
4 6 6 6
3 – – –

Ph / N Ph / Ph Ph / N Ph / Ph Ph / N Ph / Ph Ph / N Ph / Ph
– – 50 (0.5 to 4 A) – 70 (0.5 to 4 A) – 100 (0.5 to 4 A) 100 (0.5 to 4 A)
36 (6 to 63 A) 42 (6 to 63 A) 70 (6 to 63 A) 80 (6 to 63 A)
– – – 50 (0.5 to 4 A) – 70 (0.5 to 4 A) – –
36 (6 to 63 A) 42 (6 to 63 A)
– – 50 (0.5 to 4 A) – 70 (0.5 to 4 A) – 100 (0.5 to 4 A) 100 (0.5 to 4 A)
20 (6 to 63 A) 30 (6 to 63 A) 50 (6 to 25 A) 70 (6 to 63 A)
36 (32/40 A)
30 (50/63 A)
– – 50 (0.5 to 4 A) 50 (0.5 to 4 A) 70 (0.5 to 4 A) 70 (0.5 to 4 A) 100 (0.5 to 4 A) 100 (0.5 to 4 A)
10 (6 to 63 A) 20 (6 to 63 A) 15 (6 to 63 A) 30 (6 to 63 A) 25 (6 to 25 A) 50 (6 to 25 A)
20 (32/40 A) 36 (32/40 A)
15 (50/63 A) 30 (50/63 A)
– – – 50 (0.5 to 4 A) – 70 (0.5 to 4 A) – 100 (0.5 to 4 A)
10 (6 to 63 A) 15 (6 to 63 A) 25 (6 to 25 A)
20 (32/40 A)
15 (50/63 A)
– – – 25 (0.5 to 4 A) – 50 (0.5 to 4 A) – 70 (0.5 to 4 A)
6 (6 to 63 A) 10 (6 to 63 A) 20 (6 to 25 A)
15 (32/40 A)
10 (50/63 A)
– 100 % of Icu (0.5 to 4 A) 100 % of Icu (0.5 to 4 A) 100 % of Icu (0.5 to 4 A)
75 % of Icu (6 to 63 A) 50 % of Icu (6 to 63 A) 50 % of Icu (6 to 63 A) (1)
6000 6000 6000 6000 10000 10000 15000 15000

– – 15 – 20 – 25 –
– – 6 – 10 – 15 –
– – – 6 – 10 – 15
– – – 15 – 20 – 25
– – – 6 – 10 – 15
– – 100 % of Icu 100 % of Icu 100 % of Icu

– b b b
– 50°C 50°C 50°C
– Visi-trip window Visi-trip window Visi-trip window
– b b b
– b b b
IP20 IP20 IP20 IP20
IP40 IP40 IP40 IP40
Insulation class II Insulation class II Insulation class II Insulation class II
A-4 A-9 A-12 A-16
– E-2 and E-10 E-2 and E-10 E-2 and E-10
– E-2 and F-2 E-2 and F-2 E-2 and F-2
– B-17 B-17 B-17
(1) 100 % of Icu for ratings 6 to 25 A under Ue 100 to 133 V AC Ph/Ph and Ue 12 to 60 V AC Ph/N.

Acti 9 | Catalogue 2014 11


Protection Circuit breaker panorama (cont.)
Circuit protection

Selection guide (cont.)


Circuit breakers
Type C120N C120H

Standard IEC/EN 60898-1 IEC/EN 60898-1


Number of poles 1P 2, 3, 4P 1P 2, 3, 4P
Add-on residual current devices (Vigi) b b
Auxiliaries for remote tripping and indication b b
Electrical characteristics
Curves B, C B, C
Ratings (A) In 10 to 125 63, 80, 100, 125
Maximum operational voltage (V) Ue AC (50/60 Hz) 240/415, 440 240/415, 440
max
DC 125 per pole 125 per pole
Minimum operational voltage (V) Ue AC (50/60 Hz) 12 12
min
DC 12 12
Insulation voltage (V AC) Ui 500 500
Rated impulse withstand voltage (kV) Uimp 6 6
Breaking capacity
AC-Breaking capacity Ue (50/60 Hz) Ph / N Ph / Ph Ph / N Ph / Ph
IEC 60947-2 (kA) Icu 110...130 V – – – –
130 V 20 – 30 –
220...240 V 10 20 15 30
380...415 V 3 (1) 10 4.5 (1) 15
440 V – 6 – 10
500 V – – – –
Ics 75 % of Icu 50 % of Icu
IEC/EN 60898 (A) Icn 230/400 V 10000 10000 15000 15000
DC-Breaking capacity Ue DC
IEC 60947-2 (kA) Icu 60 V (1P) 10 – 15 –
125 V (1P) 10 – 15 –
250 V (2P) – 10 – 15
500 V (4P) – – – –
Ics 100 % of Icu 100 % of Icu
Other characteristics
Suitable for industrial isolation according to IEC/EN 60947-2 b b
Reference temperature IEC/EN 60947-2 50°C 50°C
Fault tripping indication – –

Positive contact indication b b


Fast closing b b
Dismounting with comb busbar in place Special comb busbar Special comb busbar
Degree of protection IP Device only IP20 IP20
Device in modular IP40 IP40
enclosure
For more detail, see page A-20 A-23
Accessories E-7, E-15 and E-28 E-7, E-15 and E-28
Auxiliaries E-7 and F-9 E-7 and F-9
Earth leakage see page (Vigi) B-22 B-22

(1) Breaking capacity under 1 pole with IT isolated neutral system (case of double fault).

12 Acti 9 | Catalogue 2014


Protection Circuit breaker panorama (cont.)
Circuit protection

NG125a NG125N NG125H NG125L

IEC/EN 60947-2 IEC/EN 60947-2 IEC/EN 60947-2 IEC/EN 60947-2


3, 4P 1P 2, 3, 4P 1P 2, 3, 4P 1P 2, 3, 4P
b b b b
b b b b

C B, C, D C B, C, D
80 to 125 10 to 125 10 to 80 10 to 80
240/415, 500 240/415, 500 240/415, 500 240/415, 500
– 125 per pole 125 per pole 125 per pole
12 12 12 12
– 12 12 12
690 690 690 690
8 8 8 8

Ph / Ph Ph / N Ph / Ph Ph / N Ph / Ph Ph / N Ph / Ph
– 50 – 70 – 100 –
– – – – – – –
– 25 50 36 70 50 100
16 6 25 9 (1) 36 12.5 (1) 50
– – 20 – 30 – 40
6 – 10 – 12 – 15
75 % of Icu 75 % of Icu 75 % of Icu 75 % of Icu
– – – – – – –

– 25 – 36 – 50 –
– 25 – 36 – 50 –
– – 25 – 36 – 50
20 – 25 – 36 – 50
100 % of Icu 100 % of Icu 100 % of Icu 100 % of Icu

b b b b
40°C 40°C 40°C 40°C
b Toggle position b Toggle position b Toggle position b Toggle position
b Red mechanical indicator b Red mechanical indicator b Red mechanical indicator b Red mechanical indicator
b b b b
b b b b
– – – –
IP20 IP20 IP20 IP20
IP40 IP40 IP40 IP40

A-27 A-29 A-31 A-33


E-26 E-26 E-26 E-26
F-14 F-14 F-14 F-14
B-27 B-27 B-27 B-27

(1) Breaking capacity under 1 pole with IT isolated neutral system (case of double fault).

Acti 9 | Catalogue 2014 13


Protection Circuit breaker panorama (cont.)
Motor protection

Selection guide (cont.)


Instantaneous circuit breakers (ICB)
Type iC60LMA NG125LMA

Standard IEC/EN 60947-2 IEC/EN 60947-2


Quality label Country approval pictogram Country approval pictogram
Number of poles 2, 3P 2, 3P
Add-on residual current devices (Vigi) b b
Auxiliaries for remote tripping and indication b b
Electrical characteristics
Curves MA (Ii = 12 In) MA (Ii = 12 In)
Ratings (A) In 1.6 to 40 4 to 80
Maximum operational voltage (V) Ue AC (50/60 Hz) 440 500
max DC 250 –
Minimum operational voltage (V) Ue AC (50/60 Hz) 12 12
min DC 12 –
Insulation voltage (V AC) Ui 500 690
Rated impulse withstand voltage (kV) Uimp 6 8
Breaking capacity
AC-Breaking capacity Ue (50/60 Hz)
IEC 60947-2 (kA) Icu 12...60 V – –
12...133 V – –
100...133 V – –
110...130 V – –
130 V – –
220...240 V 40 (1.6 to 16 A) 100
30 (25 to 40 A)
230/400 V – –
380...415 V 20 (1.6 to 16 A) 50
15 (25 to 40 A)
400/415 V – –
440 V 15 (1.6 to 16 A) 40
10 (25 to 40 A)
500 V – 15
Ics 50 % of Icu (1.6 to 40 A) 75 % of Icu
IEC/EN 60898 (A) Icn 230/400 V – –
Other characteristics
Suitable for industrial isolation according to IEC/EN 60947-2 b b
Reference temperature IEC/EN 60947-2 50°C 40°C
Fault tripping indication Visi-trip window b Toggle position
b Red mechanical indicator
Positive contact indication b b
Fast closing b b
Dismounting with comb busbar in place Upstream connection –
Degree of protection IP Device only IP20 IP20
Device in modular IP40 IP40
enclosure Insulation class II
For more detail, see page A-38 A-41
Accessories E-2 and E-10 E-26
Auxiliaries E-2 and F-2 F-14
Add-on residual current devices (Vigi) B-17 B-27

14 Acti 9 | Catalogue 2014


Circuit
Protection

Acti 9 | Catalogue 2014 A-1


Protection i DPN circuit breakers
Circuit protection

The protection of property and people against EN 60898


direct or indirect contacts, insulation faults and
fire hazards is implemented by residual current The circuit breakers are designed for protection against short-circuit and overload
devices obtained by the combination of a circuit currents, for the control and disconnection of final distribution circuits in service
sector, agricultural and industrial applications, in TT earthing system or with multiple
breaker and an earth leakage module.
earthed neutral (TN-S) requiring neutral cutoff without its protective device.
PB107139-32

Catalogue numbers
i DPN circuit breakers
4500
Type 1P+N 3P+N
N 1 3 5

DB123661

DB123389
N 1

N 2 N 2 4 6

Auxiliaries See page F-9 See page F-9


Vigi Module B-33 Module B-33
Rating (In) B curve C curve B curve C curve
DB123310

DB123312

1A - A9N21542 - -
2A - A9N21543 - -
3A - A9N21544 - -
6A A9N21535 A9N21545 - -
10 A A9N21536 A9N21546 - -
Clip on DIN rail 35 mm. Indifferent position of installation. 13 A A9N21723 A9N21724 A9N21731 A9N21732
16 A A9N21537 A9N21547 - -
IP20 IP40
DB123314

20 A A9N21538 A9N21548 - -
25 A A9N21539 A9N21549 - -
32 A A9N21540 A9N21550 - -
40 A A9N21541 A9N21551 - -
Width in 9-mm 2 6
modules
Accessories See page E-29 and E-31

Technical data
Main characteristics i DPN i DPN F i DPN N
Insulation voltage (Ui) Phase-to-phase 440 V AC - 440 V AC
Voltage rating (Ue) Phase-to-neutral 230 V AC 230 V AC 230 V AC
Phase-to-phase 400 V AC - 400 V AC
Magnetic tripping B curve 3 to 5 In - - b
C curve 5 to 10 In - b b
D curve 10 to 14 In - - b
According to EN 60898-1
Limitation class 3 3 3
Rated breaking capacity (Icn) 4500 A 6000 A 6000 A
Service breaking capacity (Ics) 100 % Icn 100 % Icn 100 % Icn
Rated breaking and making capacity on a single pole (Icn1) Icn1 = Icn Icn1 = Icn Icn1 = Icn
According to IEC 60947-2 C curve only
Rated impulse withstand voltage (Uimp) - 4 kV 4 kV
Breaking capacity (Icu) - 6 kA 10 kA
Pollution degree - 3 as per IEC 60947-1 -
(for installation in industrial environment)
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular enclosure IP40
Insulation class II
Endurance (O-C) Electrical y 20 A 20000 cycles 20000 cycles 20000 cycles
u 25 A 10000 cycles 10000 cycles 10000 cycles
Mechanical 20000 cycles 20000 cycles 20000 cycles
Operating temperature -25°C to +70°C -25°C to +70°C -25°C to +70°C
Storage temperature -40°C to +70°C -40°C to +70°C -40°C to +70°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95 % at 55°C)
Neutral opening and closing shifted relative to phases No surge upon operation of the device

A-2 Acti 9 | Catalogue 2014


Protection i DPN N circuit breakers
Circuit protection

Catalogue numbers
PB107140-32

i DPN F circuit breakers


6000
Type 1P+N

DB123389
N 1

A
N 2
PB107143-32
PB107141-32

PB107142-32

Auxiliaries See pages F-9 and E-31


Vigi See page B-33
Rating (In) C curve
1A A9N21638
2A A9N21641
3A A9N21642
6A A9N21643
10 A A9N21644
16 A A9N21645
20 A A9N21646
25 A A9N21647
32 A A9N21648
40 A A9N21649
Width in 9-mm modules 2
Accessories See page E-29 and E-31

i DPN N circuit breakers


6000
Type 1P+N 3P 3P+N
N 1 1 3 5 N 1 3 5
DB123389

DB123864

DB123661

N 2 2 4 6 N 2 4 6

Auxiliaries See pages F-9 and E-31 See pages F-9 and E-31 See pages F-9 and E-31
Vigi See page B-33 See page B-33 See page B-33
Rating (In) B curve C curve D curve C curve D curve B curve C curve D curve
1A - A9N21552 - - - - - -
2A - A9N21553 - - - - - -
3A - A9N21554 - - - - - -
4A A9N17515 A9N21722 - - - - - -
6A A9N17516 A9N21555 A9N21565 A9N21575 A9N21585 - A9N21595 A9N21605
10 A A9N17517 A9N21556 A9N21566 A9N21576 A9N21586 - A9N21596 A9N21606
13 A A9N17518 A9N21725 A9N21726 A9N21727 A9N21728 A9N17581 A9N21729 A9N21730
16 A A9N17519 A9N21557 A9N21567 A9N21577 A9N21587 - A9N21597 A9N21607
20 A A9N17520 A9N21558 A9N21568 A9N21578 A9N21588 - A9N21598 A9N21608
25 A A9N17521 A9N21559 A9N21569 A9N21579 A9N21589 - A9N21599 A9N21609
32 A A9N17522 A9N21560 A9N21570 A9N21580 A9N21590 - A9N21600 A9N21610
40 A A9N17523 A9N21561 A9N21571 A9N21581 A9N21591 - A9N21601 A9N21611
Width in 9-mm 2 6 6
modules
Accessories See page E-29 and E-31

Dimensions (mm) Weight (g)


5
DB123784

Circuit breakers Circuit breakers


Type i DPN, i DPN F, i DPN N Type Number of poles A B C D E
OFF
45 D 1P+N 115 i DPN, i DPN F, 1P+N 70 18 44 80 76
3P 310 i DPN N 3P 70 54 44 80 76
5

C
3P+N 322 3P+N 70 54 44 80 76
B
A
E

Acti 9 | Catalogue 2014 A-3


Protection iK60N circuit breakers
Circuit protection
(curve B)
PB104434-40

b Double clip for


dismounting with comb
busbar in place

b Large circuit
labelling area

b Padlocking device

b Top or bottom electrical feeding.

Connection Without accessory


Type Rating Tightening Copper cables
DB123060

torque Rigid Flexible or ferrule


14 mm
DB122945

DB122946
6.5 mm
PZ2

B curve 1 to 25 A 2 N.m 1 to 25 mm2 1 to 16 mm2


32 to 63 A 3.5 N.m 1 to 35 mm2 1 to 25 mm2

A-4 Acti 9 | Catalogue 2014


Protection iK60N circuit breakers
Circuit protection
(curve B) (cont.)

IEC/EN 60898-1
DB116619

b iK60N circuit breakers are circuit breakers which combine the following functions:
v
v
circuit protection against short-circuit currents,
circuit protection against overload currents, A
PB104459-40

PB104463-40

v disconnection, opening and closing.

iK60N circuit breaker 50/60 Hz


Breaking capacity in short circuit (Icn) as per Service breaking
IEC/EN 60898-1 capacity (Ics)
Ph/Ph 400 V 100 % of Icn
Ph/N 230 V
Rating (In) 1 to 63 A 6000 A

Catalogue numbers
iK60N circuit breaker
Type 1P 1P+N 2P 3P 4P
1 N 1 1 3 1 3 5 1 3 5 7

2 N 2 2 4 2 4 6 2 4 6 8

Auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries
Vigi iC60 Without Vigi iC60 Without Vigi iC60 Without Vigi iC60 Without Vigi iC60 Without Vigi iC60
Rating (In) Curve Curve Curve Curve Curve
B B B B B
1A A9K23101 A9K23601 A9K23201 - -
2A A9K23102 A9K23602 A9K23202 - -
3A A9K23103 A9K23603 A9K23203 - -
4A A9K23104 A9K23604 A9K23204 - -
6A A9K23106 A9K23606 A9K23206 A9K23306 A9K23406
10 A A9K23110 A9K23610 A9K23210 A9K23310 A9K23410
16 A A9K23116 A9K23616 A9K23216 A9K23316 A9K23416
20 A A9K23120 A9K23620 A9K23220 A9K23320 A9K23420
25 A A9K23125 A9K23625 A9K23225 A9K23325 A9K23425
32 A A9K23132 A9K23632 A9K23232 A9K23332 A9K23432
40 A A9K23140 A9K23640 A9K23240 A9K23340 A9K23440
50 A A9K23150 A9K23650 A9K23250 A9K23350 A9K23450
63 A A9K23163 A9K23663 A9K23263 A9K23363 A9K23463
Operating frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Width in 9-mm modules 2 4 4 6 8

Acti 9 | Catalogue 2014 A-5


Protection iK60N circuit breakers
Circuit protection
(curve B) (cont.)

Technical data
DB123310

Main characteristics
According to IEC/EN 60898-1
Insulation voltage (Ui) 440 V AC
Pollution degree 2
Rated impulse withstand voltage (Uimp) 4 kV
Clip on DIN rail 35 mm.
Thermal tripping Reference temperature 30°C
Temperature derating See the Technical Guide
Magnetic tripping B curve 3 to 5 In
DB123312

Limitation class 3
Rated making and breaking capacity of an Icn1 = Icn
individual pole (Icn1)
Additional characteristics
Degree of protection Device in modular IP40
(IEC 60529) enclosure Insulation classe II
Endurance (O-C) Electrical 10,000 cycles
Indifferent position of installation.
Mechanical 20,000 cycles
Overvoltage category (IEC 60364) III

IP40 Operating temperature -25°C to +60°C


DB123391

Storage temperature -40°C to +85°C

Weight (g)
Circuit-breaker
Type iK60N
1P 100
2P 200
3P 300
4P 400

Dimensions (mm)
78.5
4P 72
DB123392

69.5
3P 54
50
1P+N / 2P 36
5.5
1P 18

4.4

94 85 45

64
4.6

A-6 Acti 9 | Catalogue 2014


Protection iK60N circuit breakers
Circuit protection
DB116619

(curve C)

IEC/EN 60898-1

A
b iK60N circuit breakers are circuit breakers which combine the following functions:
PB104459-40

PB104463-40

v circuit protection against short-circuit currents,


v circuit protection against overload currents,
v disconnection, opening and closing.

iK60N circuit breaker 50/60 Hz


Breaking capacity in short circuit (Icn) as per Service breaking
IEC/EN 60898-1 capacity (Ics)
Ph/Ph 400 V 100 % of Icn
Ph/N 230 V
Rating (In) 1 to 63 A 6000 A

Catalogue numbers
iK60N circuit breakers
Type 1P 1P+N 2P 3P 4P
1 1 3 1 3 5 1 3 5 7

2 2 4 2 4 6 2 4 6 8

Auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries
Vigi iC60 Without Vigi iC60 Without Vigi iC60 Without Vigi iC60 Without Vigi iC60 Without Vigi iC60
Rating (In) Curve Curve Curve Curve Curve
C C C C C
1A A9K24101 A9K24601 A9K24201 - -
2A A9K24102 A9K24602 A9K24202 - -
3A A9K24103 A9K24603 A9K24203 - -
4A A9K24104 A9K24604 A9K24204 - -
6A A9K24106 A9K24606 A9K24206 A9K24306 A9K24406
10 A A9K24110 A9K24610 A9K24210 A9K24310 A9K24410
16 A A9K24116 A9K24616 A9K24216 A9K24316 A9K24416
20 A A9K24120 A9K24620 A9K24220 A9K24320 A9K24420
25 A A9K24125 A9K24625 A9K24225 A9K24325 A9K24425
32 A A9K24132 A9K24632 A9K24232 A9K24332 A9K24432
40 A A9K24140 A9K24640 A9K24240 A9K24340 A9K24440
50 A A9K24150 A9K24650 A9K24250 A9K24350 A9K24450
63 A A9K24163 A9K24663 A9K24263 A9K24363 A9K24463
Operating frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Width in 9-mm modules 2 4 4 6 8

Acti 9 | Catalogue 2014 A-7


Protection iK60N circuit breakers
Circuit protection
(curve C) (cont.)

Technical data
DB123310

Main characteristics
According to IEC/EN 60898-1
Insulation voltage (Ui) 440 V AC
Pollution degree 2
Rated impulse withstand voltage (Uimp) 4 kV
Clip on DIN rail 35 mm. Thermal tripping Reference temperature 30°C
Temperature derating See the Technical Guide
Magnetic tripping C curve 5 to 10 In
DB123312

Limitation class 3
Rated making and breaking capacity of an Icn1 = Icn
individual pole (Icn1)
Additional characteristics
Degree of protection Device in modular IP40
(IEC 60529) enclosure Insulation classe II
Endurance (O-C) Electrical 10,000 cycles
Position d’installation indifférente.
Mechanical 20,000 cycles
Overvoltage category (IEC 60364) III

IP40 Operating temperature -25°C to +60°C


DB123391

Storage temperature -40°C to +85°C

Weight (g)
Circuit-breaker
Type iK60N
1P 100
2P 200
3P 300
4P 400

Dimensions (mm)
78.5
4P 72
DB123392

69.5
3P 54
50
1P+N / 2P 36
5.5
1P 18

4.4

94 85 45

64
4.6

A-8 Acti 9 | Catalogue 2014


Protection iC60N circuit breakers
Circuit protection
(curve B, C, D)

CEI/EN 60947-2
DB116619

BS/EN 60898-1
b Disbo iC60N circuit breakers are multi-standard circuit breakers which combine
the following functions:
v circuit protection against short-circuit currents,
v circuit protection against overload currents,
v suitable for industrial isolation according to IEC/EN 60947-2, standard.
v fault tripping indication by a red mechanical indicator in circuit breaker front face. A
Alternating current (AC) 50/60 Hz
PB111066-40

PB111070-40

Breaking capacity (Icu) according to IEC/EN 60947-2 Service


Voltage (Ue) breaking
capacity
Ph/Ph (2P, 3P, 4P) 12 to 133 V 220 to 240 V 380 to 415 V 440 V
(Ics)
Ph/N (1P, 1P+N) 12 to 60 V 100 to 133 V 220 to 240 V -
Rating (In) 0.5 to 4 A 50 kA 50 kA 50 kA 25 kA 100 % of Icu
6 to 63 A 36 kA 20 kA 10 kA 6 kA 75 % of Icu
Breaking capacity (Icn) according to IEC/EN 60898-1
Voltage (Ue)
Ph/Ph 400 V
Ph/N 230 V
Rating (In) 0.5 to 63 A 6000 A

Direct current (DC)


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
capacity
Between +/- 12 to 48 V 72 V 100 to 133 V 220 to 250 V
(Ics)
Number of poles 1P 2P (in series) 3P (in series) 4P (in series)
Rating (In) 1 to 63 A 15 kA 6 kA 6 kA 15 kA 6 kA 100 % of Icu

Catalogue numbers
Disbo iC60N circuit breaker
Type 1P 2P
E45092

E45094

1 1 3

2 2 4

Auxiliaries See page E-2 and F-22 See page E-2 and F-22
Rating (In) Curve Curve
B C D B C D
0.5 A A9F43170 A9F44170 A9F45170 A9F43270 A9F44270 A9F45270
1A A9F43101 A9F44101 A9F45101 A9F43201 A9F44201 A9F45201
2A A9F43102 A9F44102 A9F45102 A9F43202 A9F44202 A9F45202
3A A9F43103 A9F44103 A9F45103 A9F43203 A9F44203 A9F45203
4A A9F43104 A9F44104 A9F45104 A9F43204 A9F44204 A9F45204
6A A9F43106 A9F44106 A9F45106 A9F43206 A9F44206 A9F45206
10 A A9F43110 A9F44110 A9F45110 A9F43210 A9F44210 A9F45210
16 A A9F43116 A9F44116 A9F45116 A9F43216 A9F44216 A9F45216
20 A A9F43120 A9F44120 A9F45120 A9F43320 A9F44220 A9F45220
25 A A9F43125 A9F44125 A9F45125 A9F43325 A9F44225 A9F45225
32 A A9F43132 A9F44132 A9F45132 A9F43232 A9F44232 A9F45232
40 A A9F43140 A9F44140 A9F45140 A9F43240 A9F44240 A9F45240
50 A A9F43150 A9F44150 A9F45150 A9F43250 A9F44250 A9F45250
63 A A9F43163 A9F44163 A9F45163 A9F43263 A9F44263 A9F45263
Width in 9-mm modules 2 4
Accessories See page E-2 and E-10 See page E-2 and E-10

Acti 9 | Catalogue 2014 A-9


Protection iC60N circuit breakers
Circuit protection
(curve B, C, D) (cont.)

b Insulated terminals IP20


Visi-trip window
b Fault tripping is indicated by a red
mechanical indicator on the front face

Positive contact indication


b Suitable for industrial isolation according to
IEC/EN 60947-2 standard.
b The presence of the green strip guarantees
physical opening of the contacts and allows
operations to be performed on the downstream
b Large circuit
circuit in complete safety
labelling area

b Insulated terminals IP20

b Clip for dismounting

b Increased product service life thanks to:


v overvoltage resistance by high level of industrial performances conception
(pollution degree, rated impulse withstand voltage and insulation voltage),
v high performance limitation (see limitation curves),
v fast closing independent of the speed of actuation of the toggle.
b Remote indication, open/closed/tripped, by optional auxiliary contacts.
b Top or bottom electrical feeding.

3P 4P
1 3 5 1 3 5 7
E45095

E45097

2 4 6 2 4 6 8

See page E-2 and F-22 See page E-2 and F-22
Curve Curve
B C D B C D
A9F43370 A9F44370 A9F45370 A9F43470 A9F44470 A9F45470
A9F43301 A9F44301 A9F45301 A9F43401 A9F44401 A9F45401
A9F43302 A9F44302 A9F45302 A9F43402 A9F44402 A9F45402
A9F43303 A9F44303 A9F45303 A9F43403 A9F44403 A9F45403
A9F43304 A9F44304 A9F45304 A9F43404 A9F44404 A9F45404
A9F43306 A9F44306 A9F45306 A9F43406 A9F44406 A9F45406
A9F43310 A9F44310 A9F45310 A9F43410 A9F44410 A9F45410
A9F43316 A9F44316 A9F45316 A9F43416 A9F44416 A9F45416
A9F43220 A9F44320 A9F45320 A9F43420 A9F44420 A9F45420
A9F43225 A9F44325 A9F45325 A9F43425 A9F44425 A9F45425
A9F43332 A9F44332 A9F45332 A9F43432 A9F44432 A9F45432
A9F43340 A9F44340 A9F45340 A9F43440 A9F44440 A9F45440
A9F43350 A9F44350 A9F45350 A9F43450 A9F44450 A9F45450
A9F43363 A9F44363 A9F45363 A9F43463 A9F44463 A9F45463
6 8
See page E-2 and E-10 See page E-2 and E-10

A-10 Acti 9 | Catalogue 2014


Protection iC60N circuit breakers
Circuit protection
(curve B, C, D) (cont.)

Connection Without accessory With accessories


Rating Tightening Copper cables 50 mm² Screw-on Multi-cables terminal
DB405585

torque Rigid Flexible Al connection Rigid Flexible


14 mm
6.5 mm or ferrule terminal for ring cables cables
terminal
PZ2

DB122945

DB122946

DB122935

DB118789

DB118787
0.5 to 25 A 2 N.m 1 to 25 mm2 1 to 16 mm2 - Ø 5 mm - -
32 to 63 A 3.5 N.m 1 to 35 mm2 1 to 25 mm2 50 mm2 3 x 16 mm2 3 x 10 mm2
DB123310

Technical data
Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 500 V AC
Pollution degree 3
Rated impulse withstand voltage (Uimp) 6 kV
Clip on DIN rail 35 mm.
Thermal tripping Reference temperature 50 °C
DB405583

Temperature derating See the Technical Guide


Magnetic tripping B curve 4 In ± 20 %
C curve 8 In ± 20 %
D curve 12 In ± 20 %
Utilization category A
According to IEC/EN 60898-1
Limitation class 3
Rated making and breaking capacity of an Icn1 = Icn
individual pole (Icn1)
Additional characteristics
Breaking capacity 40 A 4 kA
under 1 pole with IT 50/63 A 3 kA
Installation on Fishbone. 380-415 V isolated
neutral system
(case of double fault)
DB123312

Degree of protection Device only IP20


(IEC 60529) Device in modular IP40
enclosure Insulation classe II
Endurance (O-C) Electrical 10,000 cycles
Mechanical 20,000 cycles
Overvoltage category (IEC 60364) IV
Indifferent position of installation. Operating temperature -35°C to +70°C
Storage temperature -40°C to +85°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95 % to 55°C)
IP20 IP40
DB123314

Dimensions (mm) Weight (g)


78.5
4P 72
DB405584

3P 54
69.5 Circuit-breaker
50
36
2P
5.5 Type Disbo iC60N
1P 18
1P 125
2P 250
3P 375
85 45 4P 500

64
4.6

Acti 9 | Catalogue 2014 A-11


Protection iC60H circuit breakers
Circuit protection
(curve B, C, D)

CEI/EN 60947-2
DB116619

BS/EN 60898-1
b Disbo iC60H circuit breakers are multi-standard circuit breakers which combine
the following functions:
v circuit protection against short-circuit currents,
v circuit protection against overload currents,
v suitable for industrial isolation according to IEC/EN 60947-2, standard.
v fault tripping indication by a red mechanical indicator in circuit breaker front face.
PB111065-40

PB111069-40

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
capacity
Ph/Ph (2P, 3P, 4P) 12 to 133 V 220 to 240 V 380 to 415 V 440 V
(Ics)
Ph/N (1P, 1P+N) 12 to 60 V 100 to 133 V 220 to 240 V -
Rating (In) 1 to 4 A 70 kA 70 kA 70 kA 50 kA 100 % of Icu
6 to 40 A 42 kA 30 kA 15 kA 10 kA 50 % of Icu
50/63 A 42 kA - 15 kA 10 kA 50 % of Icu
Breaking capacity (Icn) according to IEC/EN 60898-1
Voltage (Ue)
Ph/Ph 400 V
Ph/N 230 V
Rating (In) 1 to 63 A 10000 A

Direct current (DC)


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
capacity
Between +/- 12 to 48 V 72 V 100 to 133 V 220 to 250 V
(Ics)
Number of poles 1P 2P (in series) 3P (in series) 4P (in series)
Rating (In) 1 to 63 A 20 kA 10 kA 10 kA 20 kA 10 kA 100 % of Icu

Catalogue numbers
Disbo iC60H circuit breaker
Type 1P 2P
E45092

E45094

1 1 3

2 2 4

Auxiliaries See page E-2 and F-2 See page E-2 and F-2
Rating (In) Curve Curve
B C D B C D
1A A9F53101 A9F54101 A9F55101 A9F53201 A9F54201 A9F55201
2A A9F53102 A9F54102 A9F55102 A9F53202 A9F54202 A9F55202
3A A9F53103 - - - - -
4A A9F53104 A9F54104 A9F55104 A9F53204 A9F54204 A9F55204
6A A9F53106 A9F54106 A9F55106 A9F53206 A9F54206 A9F55206
10 A A9F53110 A9F54110 A9F55110 A9F53210 A9F54210 A9F55210
16 A A9F53116 A9F54116 A9F55116 A9F53216 A9F54216 A9F55216
20 A A9F53120 A9F54120 A9F55120 A9F53220 A9F54220 A9F55220
25 A A9F53125 A9F54125 A9F55125 A9F53225 A9F54225 A9F55225
32 A A9F53132 A9F54132 A9F55132 A9F53232 A9F54232 A9F55232
40 A A9F53140 A9F54140 A9F55140 A9F53240 A9F54240 A9F55240
50 A A9F53150 A9F54150 A9F55150 A9F53250 A9F54250 A9F55250
63 A A9F53163 A9F54163 A9F55163 A9F53263 A9F54263 A9F55263
Width in 9-mm modules 2 4
Accessories See page E-2 and E-10 See page E-2 and E-10

A-12 Acti 9 | Catalogue 2014


Protection iC60H circuit breakers
Circuit protection
(curve B, C, D) (cont.)

b Insulated terminals IP20


Visi-trip window
b Fault tripping is indicated by a red
mechanical indicator on the front face

Positive contact indication


b Suitable for industrial isolation according to A
IEC/EN 60947-2 standard.
b The presence of the green strip guarantees
physical opening of the contacts and allows
operations to be performed on the downstream
circuit in complete safety
b Large circuit
labelling area

PB111063-40.eps

b Insulated terminals IP20

b Increased product service life thanks to:


v overvoltage resistance by high level of industrial performances conception
(pollution degree, rated impulse withstand voltage and insulation voltage),
v high performance limitation (see limitation curves),
v fast closing independent of the speed of actuation of the toggle.
b Remote indication, open/closed/tripped, by optional auxiliary contacts.
b Top or bottom electrical feeding.

3P 4P
E45095

E45097

1 3 5 1 3 5 7

2 4 6 2 4 6 8

See page E-2 and F-2 See page E-2 and F-2
Curve Curve
B C D B C D
A9F53301 A9F54301 A9F55301 A9F53401 A9F54401 A9F55401
A9F53302 A9F54302 A9F55302 A9F53402 A9F54402 A9F55402
- - - - - -
A9F53304 A9F54304 A9F55304 A9F53404 A9F54404 A9F55404
A9F53306 A9F54306 A9F55306 A9F53406 A9F54406 A9F55406
A9F53310 A9F54310 A9F55310 A9F53410 A9F54410 A9F55410
A9F53316 A9F54316 A9F55316 A9F53416 A9F54416 A9F55416
A9F53320 A9F54320 A9F55320 A9F53420 A9F54420 A9F55420
A9F53325 A9F54325 A9F55325 A9F53425 A9F54425 A9F55425
A9F53332 A9F54332 A9F55332 A9F53432 A9F54432 A9F55432
A9F53340 A9F54340 A9F55340 A9F53440 A9F54440 A9F55440
A9F53350 A9F54350 A9F55350 A9F53450 A9F54450 A9F55450
A9F53363 A9F54363 A9F55363 A9F53463 A9F54463 A9F55463
6 8
See page E-2 and E-10 See page E-2 and E-10

Acti 9 | Catalogue 2014 A-13


Protection iC60H circuit breakers
Circuit protection
(curve B, C, D) (cont.)

Connection Without accessory With accessories


Rating Tightening Copper cables 50 mm² Screw-on Multi-cables terminal
DB405585

torque Rigid Flexible Al connection Rigid Flexible


14 mm
6.5 mm or ferrule terminal for ring cables cables
terminal
PZ2

DB122945

DB122946

DB122935

DB118789

DB118787
1 to 25 A 2 N.m 1 to 25 mm2 1 to 16 mm2 - Ø 5 mm - -
32 to 63 A 3.5 N.m 1 to 35 mm2 1 to 25 mm2 50 mm2 3 x 16 mm2 3 x 10 mm2

Technical data
Main characteristics
DB123310

According to IEC/EN 60947-2


Insulation voltage (Ui) 500 V AC
Pollution degree 3
Rated impulse withstand voltage (Uimp) 6 kV
Thermal tripping Reference temperature 50 °C
Clip on DIN rail 35 mm. Temperature derating See the Technical Guide
Magnetic tripping B curve 4 In ± 20 %
C curve 8 In ± 20 %
DB405583

D curve 12 In ± 20 %
Utilization category A
According to IEC/EN 60898-1
Limitation class 3
Rated making and breaking capacity of an Icn1 = Icn
individual pole (Icn1)
Additional characteristics
Breaking capacity 40 A 4 kA
under 1 pole with IT 50/63 A 3 kA
380-415 V isolated
neutral system
(case of double fault)
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
Installation on Fishbone. enclosure Insulation classe II
Endurance (O-C) Electrical 10,000 cycles
Mechanical 20,000 cycles
DB123312

Overvoltage category (IEC 60364) IV


Operating temperature -35°C to +70°C
Storage temperature -40°C to +85°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95 % to 55°C)

Indifferent position of installation.

IP20 IP40
DB123314

A-14 Acti 9 | Catalogue 2014


Protection iC60H circuit breakers
Circuit protection
(curve B, C, D) (cont.)

Weight (g)
Circuit-breaker
Type Disbo iC60H
1P 125
2P 250

A
3P 375
4P 500

Dimensions (mm)
78.5
4P 72
DB405584

69.5
3P 54
50
2P 36
5.5
1P 18

85 45

64
4.6

Acti 9 | Catalogue 2014 A-15


Protection iC60L circuit breakers
Circuit protection
(curve B, C, K, Z)

IEC/EN 60947-2
DB116619

IEC/EN 60898-1 up to 40 A
b iC60L circuit breakers are multi-standard circuit breakers which combine the
following functions:
v circuit protection against short-circuit currents,
v circuit protection against overload currents,
v suitable for industrial isolation according to IEC/EN 60947-2, standard.
v fault tripping indication by a red mechanical indicator in circuit breaker front face.
PB104442-40

PB104452-40

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph (2P, 3P, 4P) 12 to 133 V 220 to 240 V 380 to 415 V 440 V capacity
(Ics)
Ph/N (1P) 12 to 60 V 100 to 133 V 220 to 240 V -
Rating 0.5 to 4 A 100 kA 100 kA 100 kA 70 kA 100 % of Icu
(In) 6 to 25 A 70 kA - 25 kA 20 kA 50 % of Icu (1)
32 / 40 A 70 kA - 20 kA 15 kA 50 % of Icu
50 / 63 A 70 kA - 15 kA 10 kA 50 % of Icu
Breaking capacity (Icn) according to IEC/EN 60898-1
Voltage (Ue)
Ph/Ph 400 V
Ph/N 230 V
Rating 0.5 to 40 A 15000 A
(In)

Direct current (DC)


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Between +/- 12 to 48 V 72 V 100 to 144 V 220 to 250 V capacity
(Ics)
Number of poles 1P 2P (in series) 3P (in series) 4P (in series)
Rating (In) 1 to 63 A 25 kA 15 kA 15 kA 25 kA 15 kA 100 % of Icu
Catalogue numbers
iC60L circuit breaker
Type 1P 2P
1 1 3

2 2 4

Auxiliaries See pages E-2 and F-2 See pages E-2 and F-2
Vigi iC60 See page B-17 See page B-17
Rating (In) Quality label Curve Curve
(2)
B C K Z B C K Z
0.5 A A9F93170 A9F94170 A9F95170 A9F92170 A9F93270 A9F94270 A9F95270 A9F92270
1A A9F93101 A9F94101 A9F95101 A9F92101 A9F93201 A9F94201 A9F95201 A9F92201
1.6 A - - A9F95172 A9F92172 - - A9F95272 A9F92272
2A A9F93102 A9F94102 A9F95102 A9F92102 A9F93202 A9F94202 A9F95202 A9F92202
3A A9F93103 A9F94103 A9F95103 A9F92103 A9F93203 A9F94203 A9F95203 A9F92203
4A A9F93104 A9F94104 A9F95104 A9F92104 A9F93204 A9F94204 A9F95204 A9F92204
6A A9F93106 A9F94106 A9F95106 A9F92106 A9F93206 A9F94206 A9F95206 A9F92206
10 A A9F93110 A9F94110 A9F95110 A9F92110 A9F93210 A9F94210 A9F95210 A9F92210
16 A A9F93116 A9F94116 A9F95116 A9F92116 A9F93216 A9F94216 A9F95216 A9F92216
20 A A9F93120 A9F94120 A9F95120 A9F92120 A9F93220 A9F94220 A9F95220 A9F92220
25 A A9F93125 A9F94125 A9F95125 A9F92125 A9F93225 A9F94225 A9F95225 A9F92225
32 A A9F93132 A9F94132 A9F95132 A9F92132 A9F93232 A9F94232 A9F95232 A9F92232
40 A A9F93140 A9F94140 A9F95140 A9F92140 A9F93240 A9F94240 A9F95240 A9F92240
50 A A9F93150 A9F94150 A9F95150(3) A9F92150 A9F93250 A9F94250 A9F95250 A9F92250
63 A A9F93163 A9F94163 A9F95163(3) A9F92163 A9F93263 A9F94263 A9F95263 A9F92263
Width in 9-mm modules 2 4
Accessories See pages E-2 and E-10 See pages E-2 and E-10
(1) 100 % of Icu for ratings 6 to 25 A under Ue 100 to 133 V AC Ph/Ph and Ue 12 to 60 V AC Ph/N.
(2) Information to be provided by the country.
(3) Without approval.

A-16 Acti 9 | Catalogue 2014


Protection iC60L circuit breakers
Circuit protection
(curve B, C, K, Z) (cont.)
PB104436-40

b Insulated terminals IP20

A
Visi-trip window
b Fault tripping is indicated by a red
mechanical indicator on the front face

b Large circuit
labelling area
Positive contact indication
b Suitable for industrial isolation according to
IEC/EN 60947-2 standard.
b The presence of the green strip guarantees
physical opening of the contacts and allows
operations to be performed on the downstream
circuit in complete safety

b Double clip for


dismounting with comb
b Increased product service life thanks to:
busbar in place
v overvoltage resistance by high level of industrial performances conception
(pollution degree, rated impulse withstand voltage and insulation voltage),
v high performance limitation (see limitation curves),
v fast closing independent of the speed of actuation of the toggle.
b Remote indication, open/closed/tripped, by optional auxiliary contacts.
b Top or bottom electrical feeding.

3P 4P
1 3 5 1 3 5 7

2 4 6 2 4 6 8

See pages E-2 and F-2 See pages E-2 and F-2
See page B-17 See page B-17
Curve Curve
B C K Z B C K Z
A9F93370 A9F94370 A9F95370 A9F92370 A9F93470 A9F94470 A9F95470 A9F92470
A9F93301 A9F94301 A9F95301 A9F92301 A9F93401 A9F94401 A9F95401 A9F92401
- - A9F95372 A9F92372 - - A9F95472 A9F92472
A9F93302 A9F94302 A9F95302 A9F92302 A9F93402 A9F94402 A9F95402 A9F92402
A9F93303 A9F94303 A9F95303 A9F92303 A9F93403 A9F94403 A9F95403 A9F92403
A9F93304 A9F94304 A9F95304 A9F92304 A9F93404 A9F94404 A9F95404 A9F92404
A9F93306 A9F94306 A9F95306 A9F92306 A9F93406 A9F94406 A9F95406 A9F92406
A9F93310 A9F94310 A9F95310 A9F92310 A9F93410 A9F94410 A9F95410 A9F92410
A9F93316 A9F94316 A9F95316 A9F92316 A9F93416 A9F94416 A9F95416 A9F92416
A9F93320 A9F94320 A9F95320 A9F92320 A9F93420 A9F94420 A9F95420 A9F92420
A9F93325 A9F94325 A9F95325 A9F92325 A9F93425 A9F94425 A9F95425 A9F92425
A9F93332 A9F94332 A9F95332 A9F92332 A9F93432 A9F94432 A9F95432 A9F92432
A9F93340 A9F94340 A9F95340 A9F92340 A9F93440 A9F94440 A9F95440 A9F92440
A9F93350 A9F94350 A9F95350 A9F92350 A9F93450 A9F94450 A9F95450 A9F92450
A9F93363 A9F94363 A9F95363 A9F92363 A9F93463 A9F94463 A9F95463 A9F92463
4 6
See pages E-2 and E-10 See pages E-2 and E-10

Acti 9 | Catalogue 2014 A-17


Protection iC60L circuit breakers
Circuit protection
(curve B, C, K, Z) (cont.)

Connection Without accessory With accessories


Rating Tightening Copper cables 50 mm² Screw-on Multi-cables terminal
DB123060

torque Rigid Flexible Al connection Rigid Flexible


14 mm
6.5 mm or ferrule terminal for ring cables cables
terminal
PZ2

DB122945

DB122946

DB122935

DB118789

DB118787
0.5 to 25 A 2 N.m 1 to 25 mm2 1 to 16 mm2 - Ø 5 mm - -
32 to 63 A 3.5 N.m 1 to 35 mm2 1 to 25 mm2 50 mm2 3 x 16 mm2 3 x 10 mm2

Technical data
DB123310

Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 500 V AC
Pollution degree 3
Rated impulse withstand voltage (Uimp) 6 kV
Clip on DIN rail 35 mm. Thermal tripping Reference temperature 50 °C
Temperature derating See the Technical Guide
Magnetic tripping B curve 4 In ± 20 %
C curve 8 In ± 20 %
DB123312

K curve 12 In ± 20 %
Z curve 3 In ± 20 %
Utilization category A
According to IEC/EN 60898-1
Limitation class 3
Rated making and breaking capacity of an Icn1 = Icn
Indifferent position of installation. individual pole (Icn1)
Additional characteristics
Breaking capacity 40 A 4 kA
under 1 pole with IT 50/63 A 3 kA
380-415 V isolated
IP20 IP40
DB123314

neutral system
(case of double fault)
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
enclosure Insulation classe II
Endurance (O-C) Electrical 10,000 cycles
Mechanical 20,000 cycles
Overvoltage category (IEC 60364) IV
Operating temperature -35°C to +70°C
Storage temperature -40°C to +85°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95 % to 55°C)

A-18 Acti 9 | Catalogue 2014


Protection iC60L circuit breakers
Circuit protection
(curve B, C, K, Z) (cont.)

Weight (g)
Circuit-breaker
Type iC60L
1P 125
2P 250

A
3P 375
4P 500

Dimensions (mm)
78.5
4P 72
DB123586

69.5
3P 54
50
2P 36
5.5
1P 18

4.4

45
94 85

64
4.6

Acti 9 | Catalogue 2014 A-19


Protection C120N circuit breakers
Circuit protection
(curves B, C, D)

IEC/EN 60898-1, IEC 60947-2


PB107904-30

PB107907-40
C120N circuit breakers are multistandard circuit breakers that combine the following
functions:
b circuit protection against short-circuit currents,
b circuit protection against overload currents,
b suitability for isolation in the industrial sector to IEC/EN 60947-2,
b fault tripping and indication by adding auxiliaries.

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) to IEC/EN 60947-2 Service
Type Voltage (V) breaking
capacity (Ics)
PB107910 -30

1P 130 V 220 to 240 V 380 to 415 V 440 V


Rating (In) 63 to 125 A 20 kA 10 kA 3 kA (1) - 75 % Icu
2P/3P/4P 130 V 220 to 240 V 380 to 415 V 440 V
63 to 125 A - 20 kA 10 kA 6 kA 75 % Icu
Breaking capacity (Icn) to IEC/EN 60898-1
Type Voltage (V)
1P, 2P, 3P, 4P 230 to 400 V
Rating (In) 63 to 125 A 10000 A 75 % Icn
(1) One-pole breaking capacity in IT isolated neutral system (double fault).

Direct current (DC)


PB107913-30

Breaking capacity (Icu) to IEC/EN 60947-2 Service breaking


Type Voltage (V) capacity (Ics)
1P 24/48 V 125 V 250 V
Rating (In) 63 to 125 A 10 kA 10 kA - 100 % Icu
2P (in series) 24/48 V 125 V 250 V
63 to 125 A - - 10 kA 100 % Icu

Catalogue numbers
C120N circuit breaker
Type 1P 2P
1 1 3

2 2 4

Auxiliaries See pages E-7 and F-9 See pages E-7 and F-9
Vigi C120 See page B-22 See page B-22
Rating (In) Curve Curve
B C D B C D
63 A A9N18340 A9N18356 A9N18378 A9N18344 A9N18360 A9N18382
80 A A9N18341 A9N18357 A9N18379 A9N18345 A9N18361 A9N18383

100 A A9N18342 A9N18358 A9N18380 A9N18346 A9N18362 A9N18384

125 A A9N18343 A9N18359 A9N18381 A9N18347 A9N18363 A9N18385

Width in 9-mm modules 3 6


Accessories See pages E-7 and E-15 See pages E-7 and E-15
(1) Country France only

A-20 Acti 9 | Catalogue 2014


Protection C120N circuit breakers
Circuit protection
(curves B, C, D) (cont.)

b Terminals insulated to
IP20
PB107907-40

b Location for 4 clip-on A


terminal markers

Positive contact indication


b Suitability for isolation in the industrial sector to
IEC/EN 60947-2.
b The presence of the green strip guarantees that
the contacts open physically and allows work to be
carried out safely on the downstream circuit.

b Longer product service life thanks to:


v good overvoltage withstand capacity: products designed to offer a high industrial
performance level (degree of pollution, rated impulse withstand voltage and
insulation voltage).
v high limitation performances (see limitation curves).
v fast closure independent of toggle operating speed.
b Remote indication of the open/closed/tripped state by auxiliary contacts (optional).
b Power supply from above or below.

3P 4P
1 3 5 1 3 5 7

2 4 6 2 4 6 8

See pages E-7 and F-9 See pages E-7 and F-9
See page B-22 See page B-22
Curve Curve
B C D B C D
A9N18348 A9N18364 A9N18386 A9N18352 A9N18371 A9N18390
A9N18349 A9N18365 A9N18387 A9N18353 A9N18372 A9N18391
A9N18373(1)
A9N18350 A9N18367 A9N18388 A9N18354 A9N18374 A9N18392
A9N18375(1)
A9N18351 A9N18369 A9N18389 A9N18355 A9N18376 A9N18393
A9N18377(1)
9 12
See pages E-7 and E-15 See pages E-7 and E-15

Acti 9 | Catalogue 2014 A-21


Protection C120N circuit breakers
Circuit protection
(curves B, C, D) (cont.)

Connection Without access. With accessories


Rating Tightening Copper cables 50 mm² Al Screw-on Multi-cable terminal
DB126143

15 mm
torque Rigid/ Flexible or Terminal connection Rigid Flexible
6.5 mm semi-rigid with ferrule for ring cables cables
terminal(1)

DB122946

DB122935

DB118789

DB118787
DB122945
PZ2

63 to 125 A 3.5 N.m 1 to 50 mm2 1.5 to 35 mm2 16 to 50 mm2 Ø 5 mm 3 x 16 mm² 3 x 10 mm²


(1) For lugs up to 63 A, front or rear access.

Technical data
DB118767

Main characteristics
To IEC/EN 60947-2
Insulation voltage (Ui) 500 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 6 kV

Clips onto 35 mm DIN rail. Thermal tripping Reference temperature 50°C


To IEC/EN 60898-1
Magnetic tripping Curve B 3 and 5 In
Curve C 5 and 10 In
DB122831

Curve D 10 and 14 In
Limitation class 3
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in a modular IP40
enclosure
Endurance (O-C) Electrical 63 A 10000 cycles (O-C)
Any installation position.
80...125 A 5000 cycles (O-C)
Mechanical 20000 cycles
Operating temperature -30°C to +70°C
IP20 IP40
DB122932

Storage temperature -40°C to +80°C


Tropicalisation (IEC 60068-1) Treatment 2 (relative humidity 95 % at 55°C)

Weight (g)
Circuit breaker
Type C120N
1P 205
2P 410
3P 615
4P 820

Dimensions (mm)
DB124335

A-22 Acti 9 | Catalogue 2014


Protection C120H circuit breakers
Circuit protection
(curves B, C, D)

IEC/EN 60898-1, IEC 60947-2


PB107903-30

PB107906-30
C120H circuit breakers are multistandard circuit breakers that combine the following
functions:
b circuit protection against short-circuit currents
b circuit protection against overload currents
b suitability for isolation in the industrial sector to IEC/EN 60947-2
b fault tripping and indication by adding auxiliaries.
A
Alternating current (AC) 50/60 Hz
Breaking capacity (Icu) to IEC/EN 60947-2 Service
Type Voltage (V) breaking
capacity (Ics)
PB107909-30

1P 130 V 220 to 240 V 380 to 415 V 440 V


Rating (In) 63 to 125 A 30 kA 15 kA 4,5 kA (1) - 50 % Icu
2P, 3P, 4P 130 V 220 to 240 V 380 to 415 V 440 V
63 to 125 A - 30 kA 15 kA 10 kA 50 % Icu
Breaking capacity (Icn) to IEC/EN 60898-1
Type Voltage (V)
1P, 2P, 3P, 4P 230 to 400 V
Rating (In) 63 to 125 A 15000 A 50 % Icn
(1) One-pole breaking capacity in IT isolated neutral system (double fault).
PB107912-30

Direct current (DC)


Breaking capacity (Icu) to IEC/EN 60947-2 Service breaking
Type Voltage (V) capacity (Ics)
1P 24/48 V 125 V 250 V
Rating (In) 63 to 125 A 15 kA 15 kA - 100 % Icu
2P (in series) 24/48 V 125 V 250 V
63 to 125 A - - 15 kA 100 % Icu

Catalogue numbers
C120H circuit breaker
Type 1P 2P
1 1 3

2 2 4

Auxiliaries See pages E-7 and F-9 See pages E-7 and F-9
Vigi C120 See page B-22 See page B-22
Rating (In) Curve Curve
B C D B C D
63 A A9N18401 A9N18445 A9N18489 A9N18412 A9N18456 A9N18500
80 A A9N18402 A9N18446 A9N18490 A9N18413 A9N18457 A9N18501
100 A A9N18403 A9N18447 A9N18491 A9N18414 A9N18458 A9N18502
125 A A9N18404 A9N18448 A9N18492 A9N18415 A9N18459 A9N18503
Width in 9 mm modules 3 6
Accessories See pages E-7 and E-15 See pages E-7 and E-15

Acti 9 | Catalogue 2014 A-23


Protection C120H circuit breakers
Circuit protection
(curves B, C, D) (cont.)

b Terminals insulated to
IP20
PB107906-40

b Location for 4 clip-on


terminal markers

Positive contact indication


b Suitability for isolation in the industrial sector to
IEC/EN 60947-2.
b The presence of the green strip guarantees that
the contacts open physically and allows work to be
carried out safely on the downstream circuit.

b Longer product service life thanks to:


v good overvoltage withstand capacity: products designed to provide a high
industrial performance level (degree of pollution, rated impulse withstand voltage
and insulation voltage).
v high limitation performances (see limitation curves).
v fast closure independent of toggle operating speed.
b Remote indication of the open/closed/tripped state by auxiliary contacts (optional).
b Power supply from above or below.

3P 4P
1 3 5 1 3 5 7

2 4 6 2 4 6 8

See pages E-7 and F-9 See pages E-7 and F-9
See page B-22 See page B-22
Curve Curve
B C D B C D
A9N18423 A9N18467 A9N18511 A9N18434 A9N18478 A9N18522
A9N18424 A9N18468 A9N18512 A9N18435 A9N18479 A9N18523
A9N18425 A9N18469 A9N18513 A9N18436 A9N18480 A9N18524
A9N18426 A9N18470 A9N18514 A9N18437 A9N18481 A9N18525
9 12
See pages E-7 and E-15 See pages E-7 and E-15

A-24 Acti 9 | Catalogue 2014


Protection C120H circuit breakers
Circuit protection
(curves B, C, D) (cont.)

Connection Without access. With accessories


Rating Tightening Copper cables 50 mm² Screw-on Multi-cable terminal
DB126143

15 mm
torque Rigid Flexible or Al term. connection Rigid Flexible
6.5 mm with ferrule for ring cables cables
terminal (1)

DB122945
A

DB122946

DB122935

DB118789

DB118787
PZ2

63 to 125 A 3.5 N.m 1 to 50 mm2 1.5 to 35 mm2 16 to 50 mm2 Ø 5 mm 3 x 16 mm² 3 x 10 mm²


(1) For lugs up to 63 A, front or rear accessories.

Technical data
DB118767

Main characteristics
To IEC/EN 60947-2
Insulation voltage (Ui) 500 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 6 kV

Clips onto 35 mm DIN rail. Thermal tripping Reference temperature 50°C


To IEC/EN 60898-1
Magnetic tripping Curve B 3 and 5 In
Curve C 5 and 10 In
DB122831

Curve D 10 and 14 In
Limitation class 3
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in a modular IP40 (IPXXD)
enclosure
Endurance (O-C) Electrical 63 A 10000 cycles (O-C)
Any installation position.
80...125 A 5000 cycles (O-C)
Mechanical 20000 cycles
Operating temperature -30°C to +70°C
IP20 IP40
DB122932

Storage temperature -40°C to +80°C


Tropicalisation (IEC 60068-1) Treatment 2 (relative humidity 95% at 55°C)

Weight (g)
Circuit breaker
Type C120H
1P 205
2P 410
3P 615
4P 820

Dimensions (mm)
DB124335

Acti 9 | Catalogue 2014 A-25


Protection NG125 circuit breakers
Circuit protection
(curves B, C, D)

3P, 3P+N, 4P u 80 A
b Voltage taps:
v auxiliaries power supply
v measurement
v emergency stop
v remote reporting

b Cable strength: 1P, 2P


v ribbed cage b Padlocking in position:
v terminal depth O or I, manual control is
v tightening by Allen hex inhibited, tripping is enabled
key (NG125 u 80 A)
056918N_SE-90

b Test button to check


satisfactory operation of
the tripping mechanism

b Pull-out strength
v metallic lock
3P, 3P+N, 4P
b Integrated padlocking
device

b Central manual control, 3


positions:
b Impact and vibration resistance: v ON
v high-strength enclosure v tripped on fault
v IK 05 v open
b Circuit breaker tripped indicator

b Electric power supply


through the top or bottom
b Positive contact indication:
DB123493

v suitability for isolation in the industrial sector to IEC/EN 60947-2


v the presence of the green strip guarantees that the contacts open physically
and allows work to be carried out safely on the downstream circuit

b Longer product service life due to:


v good overvoltage withstand capacity,
v high limitation performances,
v fast closure independent of the speed of actuation of the toggle.

A-26 Acti 9 | Catalogue 2014


Protection NG125a circuit breakers
Circuit protection
(curve C)

IEC/EN 60947-2
DB116619

b NG125a circuit breakers are circuit breakers which combine the following
functions:
v circuit protection against short-circuit currents,
v circuit protection against overload currents,
v suitability for isolation in the industrial sector to IEC/EN 60947-2,
v tripping upon fault is indicated by a red mechanical state indicator light on the front
face of the circuit breaker. A
056913N_SE-28

056914N_SE-28

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph (3P, 4P) 380 to 415 V 500 V capacity (Ics)
Rating (In) 80 to 125 A 16 kA 8 kA 75 % of Icu

Direct current (DC)


NG125a 3P NG125a 4P
Breaking capacity (Icu) to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph 375 V 500 V capacity (Ics)
Number of poles 3P 4P
Rating (In) 80 to 125 A 20 kA 20 kA 100 % of Icu

Catalogue numbers
NG125a circuit breaker
Type 3P 4P
E45095

E45097

1 3 5 1 3 5 7

2 4 6 2 4 6 8

Auxiliaries See page B-27 and F-14


Rating (In) Quality label Curve C Curve C
(1)

80 A 18603 18607
100 A 18604 18608
125 A 18605 18609
Width in 9 mm modules 9 12
Accessories see page E-26

(1) Information to be supplied by the country concerned.

Acti 9 | Catalogue 2014 A-27


Protection NG125a circuit breakers
Circuit protection
(curve C) (cont.)

Connection Without With


accessories accessories
Rating Tightening Copper cables 70 mm2 Screw-on Small Multi-cable
DB122589

torque Al connection ring terminal


20 mm
Rigid Flexible or terminal for ring terminal Rigid Flexible
with terminal cables cables
ferrule

DB122945

DB122946

DB123410

DB123488

DB118789

DB118787
6 mm
80 6 N.m 16 to 70 mm2 10 to 50 mm2 25 to 70 mm2 2 x 35 mm2 1 x 70 mm2 3 x 16 mm2 3 x 10 mm2
to 125 A 1 x 50 mm2
b Upstream voltage taps for each pole, by 6.35 mm Fast-on terminal.

Technical data
DB123310

Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 690 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 8 kV
Clips on to 35 mm DIN rail. 40°C
Thermal Reference
tripping temperature
Magnetic Curve C 8 In ± 20 %
tripping (Ii)
DB123312

Utilization category A
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
enclosure
Endurance (O-C) Electrical 5000 cycles
Any installation position. Mechanical 20,000 cycles
Operating temperature -30°C to +70°C
Storage temperature -40°C to +70°C
IP20 IP40
DB123314

Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95 % at 55°C)

Weight (g)
Circuit breaker
Type NG125a
3P 720
4P 960

Dimensions (mm)
DB122588

DB123487

27.75 25.5 27.75 79.5 28.5

16.25 16.25

70.5 70.5

16.25 16.25

53.25 28.5 51

Spacing for mounting on panel

A-28 Acti 9 | Catalogue 2014


Protection NG125N circuit breakers
Circuit protection
(curves B, C, D) (cont.)

IEC/EN 60947-2
DB116619

b NG125N circuit breakers are circuit breakers which combine the following
functions:
v circuit protection against short-circuit currents,
v circuit protection against overload currents,
v suitability for isolation in the industrial sector to IEC/EN 60947-2,
v tripping upon fault is indicated by a red mechanical state indicator light on the front A
face of the circuit breaker.
056900_SE-28

056902_SE-28

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph - - 220 to - 380 to 440 V 500 V capacity
(2P, 3P, 3P+N, 4P) 240 V 415 V (Ics)
Ph/N 110 to 220 to - 380 to - - -
(1P) 130 V 240 V 415 V
Rating 10 to 125 A 50 kA 25 kA 50 kA 6 kA(2) 25 kA 20 kA 10 kA 75 % of Icu
(In)
NG125N 1P NG125N 2P

Direct current (DC)


056903_SE-28

056335_SE-28

Breaking capacity (Icu) to IEC/EN 60947-2 Service


Voltage (Ue) breaking
Ph/Ph (2P, 3P, 3P+N, 4P) - - 250 V 500 V capacity
Ph/N (1P) 60 V 125 V - -
(Ics)
Number of poles 1P 1P 2P 4P
Rating (In) 10 to 125 A 25 kA 25 kA 25 kA 25 kA 100 % of Icu

NG125N 3P NG125N 4P

Catalogue numbers
NG125N circuit breaker
Type 1P 2P 3P 3P+N 4P
E45092

E45094

E45095

DB122592

E45097

1 1 3 1 3 5 N 1 3 5 1 3 5 7

2
2 4 2 4 6 N 2 4 6 2 4 6 8

Auxiliaries See page F-14 – Vigi NG125 add-on residual current device, see page B-27
Rating (In) Quality label Curve Curve Curve Curve Curve
(1)
C C B C D C B C D
10 A 18610 18621 - 18632 - - - 18649 -
16 A 18611 18622 - 18633 - - - 18650 -
20 A 18612 18623 - 18634 - - - 18651 -
25 A 18613 18624 - 18635 - - - 18652 -
32 A 18614 18625 - 18636 - - - 18653 -
40 A 18615 18626 - 18637 - - - 18654 -
50 A 18616 18627 - 18638 - - - 18655 -
63 A 18617 18628 - 18639 - - - 18656 -
80 A 18618 18629 18663 18640 18669 18646 18666 18658 18672
100 A - - 18664 18642 18670 18647 18667 18660 18673
125 A - - 18665 18644 18671 18648 18668 18662 18674
Width in 9 mm modules 3 6 9 12 12
Accessories See page E-26

(1) Information to be supplied by the country concerned.


(2) Breaking capacity under 1 pole in IT isolated neutral system (case of a double fault).
Acti 9 | Catalogue 2014 A-29
Protection NG125N circuit breakers
Circuit protection
(curves B, C, D) (cont.)

Connection Without With


accessories accessories
Rating Tightening Copper cables 70 mm2 Screw-on Small Multi-cable
DB122861

NG125
u 80 A torque Al connection ring terminal
20 mm
Rigid Flexible or terminal for ring terminal Rigid Flexible
with terminal cables cables
ferrule

DB122945

DB122946

DB123410

DB123488

DB118789

DB118787
PZ2
6.5 mm 6 mm
NG125
y 63 A 10 3.5 N.m 1.5 to 50 mm2 1 to 35 mm2 - - - 3 x 16 mm2 3 x 10 mm2
to 63 A
80 6 N.m 16 to 70 mm2 10 to 50 mm2 25 to 70 mm2 2 x 35 mm2 1 x 70 mm2
to 125 A 1 x 50 mm2
b On 3P, 3P+N and 4P u 80 A: upstream voltage taps for each pole, by 6.35 mm Fast-on terminal.

Technical data
DB123310

Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 690 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 8 kV
Clips on to 35 mm DIN rail. Thermal Reference 40°C
tripping temperature
Magnetic Curve B 4 In ± 20 %
DB123312

tripping (Ii) Curve C 8 In ± 20 %


Curve D 12 In ± 20 %
Utilization category A
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
Any installation position. enclosure
Endurance (O-C) Electrical y 63 A: 10,000 cycles
u 63 A: 5000 cycles
IP20 IP40
DB123314

Mechanical 20,000 cycles


Operating temperature -30°C to +70°C
Storage temperature -40°C to +70°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95 % at 55°C)

Dimensions (mm)
Weight (g)
DB404852

3P+N
4P Circuit breaker
Type NG125N
1P 240
2P 480
3P 720
3P+N 960
4P 960

27.75 25.5 27.75 79.5 28.5


DB123487

16.25 16.25

70.5 70.5

16.25 16.25

53.25 28.5 51

Spacing for mounting on panel

A-30 Acti 9 | Catalogue 2014


Protection NG125H circuit breakers
Circuit protection
(curve C)

IEC/EN 60947-2
DB116619

b NG125H circuit breakers are circuit breakers which combine the following
functions:
v circuit protection against short circuit currents,
v circuit protection against overload currents,
v suitability for isolation in the industrial sector to IEC/EN 60947-2,
v tripping upon fault is indicated by a red mechanical state indicator light on the front
face of the circuit breaker. A
056915N_SE-28

056916N_SE-28

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph - -
220 to - 380 to 440 V 500 V capacity
(2P, 3P, 4P) 240 V 415 V (Ics)
Ph/N 110 to 220 to - 380 to - - -
(1P) 130 V 240 V 415 V
Rating 10 to 80 A 70 kA 36 kA 70 kA 9 kA(2) 36 kA 30 kA 12 kA 75 % of Icu
NG125H 1P NG125H 2P (In)
056917N_SE-28

056918N_SE-28

Direct current (DC)


Breaking capacity (Icu) to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph (2P, 3P, 3P+N, 4P) - - 250 V 500 V capacity
Ph/N (1P) 60 V 125 V - -
(Ics)
Number of poles 1P 1P 2P 4P
Rating (In) 10 to 80 A 36 kA 36 kA 36 kA 36 kA 100 % of Icu
NG125H 3P NG125H 4P

Catalogue numbers
NG125H circuit breaker
Type 1P 2P 3P 4P
1 1 3 1 3 5 1 3 5 7
E45092

E45094

E45095

E45097

2
2 4 2 4 6 2 4 6 8

Auxiliaries See page F-14 –


Vigi NG125 add-on residual current device,
see page B-27
Rating (In) Quality label Curve C Curve C Curve C Curve C
(1)

10 A 18705 18714 18723 18732


16 A 18706 18715 18724 18733
20 A 18707 18716 18725 18734
25 A 18708 18717 18726 18735
32 A 18709 18718 18727 18736
40 A 18710 18719 18728 18737
50 A 18711 18720 18729 18738
63 A 18712 18721 18730 18739
80 A 18713 18722 18731 18740
Width in 9 mm modules 3 6 9 12
Accessories See page E-26

(1) Information to be supplied by the country concerned.


(2) Breaking capacity under 1 pole in IT isolated neutral system (case of a double fault).

Acti 9 | Catalogue 2014 A-31


Protection NG125H circuit breakers
Circuit protection
(curve C) (cont.)

Connection Without With


accessories accessories
Rating Tightening Copper cables 70 mm2 Screw-on Small Multi-cable
DB122861

NG125
80 A torque Al connection ring terminal
20 mm
Rigid Flexible or terminal for ring terminal Rigid Flexible
with terminal cables cables
ferrule

DB122945

DB122946

DB123410

DB123488

DB118789

DB118787
PZ2
6.5 mm 6 mm
NG125
y 63 A 10 3.5 N.m 1.5 to 50 mm2 1 to 35 mm2 - - - 3 x 16 mm2 3 x 10 mm2
to 63 A
80 A 6 N.m 16 to 70 mm2 10 to 50 mm2 25 to 70 mm2 2 x 35 mm2 1 x 70 mm2
1 x 50 mm2
b On 3P and 4P 80 A: upstream voltage taps for each pole, by 6.35 mm Fast-on terminal.

Technical data
DB123310

Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 690 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 8 kV

Clips on to 35 mm DIN rail. Thermal Reference 40°C


tripping temperature
Magnetic Curve C 8 In ± 20 %
DB123312

tripping (Ii)
Utilization category A
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
enclosure Insulation class II
Endurance (O-C) Electrical y 63 A: 10,000 cycles
Any installation position. u 63 A: 5000 cycles
Mechanical 20,000 cycles
IP20 IP40
DB123314

Operating temperature -30°C to +70°C


Storage temperature -40°C to +70°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95 % at 55°C)

Dimensions (mm)
Weight (g)
DB122591

Circuit breaker
Type NG125H
1P 240
2P 480
3P 720
4P 960

27.75 25.5 27.75 79.5 28.5


DB123487

16.25 16.25

70.5 70.5

16.25 16.25

53.25 28.5 51

Spacing for mounting on panel

A-32 Acti 9 | Catalogue 2014


Protection NG125L circuit breakers
Circuit protection
(curves B, C, D)

IEC/EN 60947-2
DB116619

b NG125L circuit breakers are circuit breakers which combine the following
functions:
v circuit protection against short-circuit currents;
v circuit protection against overload currents;
v suitability for isolation in the industrial sector to IEC/EN 60947-2;
v tripping upon fault is indicated by a red mechanical state indicator light on the front
face of the circuit breaker.
A
56337_SE-28

56338_SE-28

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph - - 220 to - 380 to 440 V 500 V capacity
(2P, 3P, 4P) 240 V 415 V (Ics)
Ph/N (1P) 110 to 220 to - 380 to - - -
130 V 240 V 415 V
Rating 10 to 100 kA 50 kA 100 kA 12.5 kA(2) 50 kA 40 kA 15 kA 75 % of Icu
(In) 80 A
NG125L 1P NG125L 2P
56339_SE-28

56340_SE-28

Direct current (DC)


Breaking capacity (Icu) to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph (2P, 3P, 3P+N, 4P) - - 250 V 500 V capacity
Ph/N (1P) 60 V 125 V - -
(Ics)
Number of poles 1P 1P 2P 4P
Rating (In) 10 to 80 A 50 kA 50 kA 50 kA 50 kA 100 % of Icu

NG125L 3P NG125L 4P

Catalogue numbers
NG125L circuit breaker
Type 1P 2P 3P 4P
E45092

E45094

E45095

E45097

1 1 3 1 3 5 1 3 5 7

2
2 4 2 4 6 2 4 6 8

Auxiliaries See page F-14 – Vigi NG125 add-on residual current device, see page B-27
Rating (In) Quality label Curve Curve Curve Curve
(1)
B C D B C D B C D B C D
10 A 18741 18777 18830 18750 18788 18839 18759 18799 18848 18768 18821 18857
16 A 18742 18778 18831 18751 18789 18840 18760 18800 18849 18769 18822 18858
20 A 18743 18779 18832 18752 18790 18841 18761 18801 18850 18770 18823 18859
25 A 18744 18780 18833 18753 18791 18842 18762 18802 18851 18771 18824 18860
32 A 18745 18781 18834 18754 18792 18843 18763 18803 18852 18772 18825 18861
40 A 18746 18782 18835 18755 18793 18844 18764 18804 18853 18773 18826 18862
50 A 18747 18783 18836 18756 18794 18845 18765 18805 18854 18774 18827 18863
63 A 18748 18784 18837 18757 18795 18846 18766 18806 18855 18775 18828 18864
80 A 18749 18785 18838 18758 18796 18847 18767 18807 18856 18776 18829 18865
Width in 9 mm modules 3 6 9 12
Accessories See page E-26

(1) Information to be supplied by the country concerned.


(2) Breaking capacity under 1 pole in IT isolated neutral system (case of a double fault).

Acti 9 | Catalogue 2014 A-33


Protection NG125L circuit breakers
Circuit protection
(curves B, C, D) (cont.)

Connection Without With


accessories accessories
Rating Tightening Copper cables 70 mm2 Screw-on Small Multi-cable
DB122861

NG125
80 A torque Al connection ring terminal
20 mm
Rigid Flexible or terminal for ring terminal Rigid Flexible
with terminal cables cables
ferrule

DB122945

DB122946

DB123410

DB123488

DB118789

DB118787
PZ2
6.5 mm 6 mm
NG125
y 63 A 10 3.5 N.m 1.5 to 50 mm2 1 to 35 mm2 - - - 3 x 16 mm2 3 x 10 mm2
to 63 A
80 A 6 N.m 16 to 70 mm2 10 to 50 mm2 25 to 70 mm2 2 x 35 mm2 1 x 70 mm2
1 x 50 mm2
b On 3P and 4P 80 A: upstream voltage taps for each pole, by 6.35 mm Fast-on terminal.

Technical data
DB123310

Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 690 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 8 kV
Thermal Reference 40°C
Clips on to 35 mm DIN rail.
tripping temperature
Magnetic Curve B 4 In ± 20 %
DB123312

tripping (Ii) Curve C 8 In ± 20 %


Curve D 12 In ± 20 %
Utilization category A
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
Any installation position. enclosure
Endurance (O-C) Electrical y 63 A: 10,000 cycles
u 63 A: 5000 cycles
IP20 IP40
DB123314

Mechanical 20,000 cycles


Operating temperature -30°C to +70°C
Storage temperature -40°C to +70°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95 % at 55°C)

Dimensions (mm)
Weight (g)
DB122591

Circuit breaker
Type NG125L
1P 240
2P 480
3P 720
4P 960

27.75 25.5 27.75 79.5 28.5


DB123487

16.25 16.25

70.5 70.5

16.25 16.25

53.25 28.5 51

Spacing for mounting on panel

A-34 Acti 9 | Catalogue 2014


DC circuit supplementary C60H-DC
protectors for feeders / C curve
distribution systems

IEC/EN 60947-2

A
The C60H-DC supplementary protectors are used in direct current circuits
(Industrial control and automations, transport, renewable energy...).
They combine the following functions of circuit protection against short-circuit and
PB107193-34.eps

PB107194-34.eps

overload currents, control and isolation.

Direct current (DC)


Breaking capacity (Icu) according to IEC/EN 60947-2 Rated service
Type breaking
capacity (Ics)
1P 110 V 220 V 250 V 440 V 500 V
Rating 0.5 to 63 A 20 kA 10 kA 6 kA - - 75 % Icu
(In)
2P (in series) 110 V 220 V 250 V 440 V 500 V
0.5 to 63 A - 20 kA 20 kA 10 kA 6 kA 75 % Icu

Catalogue numbers
C60H-DC
Type 1P 2P
DB116588

DB124110

DB124111

Supply from above or below, Supply from Supply from


observing the polarity above below
Auxiliaries See page F-9
Rating (In) Courbe C Courbe C
0.5 A A9N61500 A9N61520
1A A9N61501 A9N61521
2A A9N61502 A9N61522
3A A9N61503 A9N61523
4A A9N61504 A9N61524
5A A9N61505 A9N61525
6A A9N61506 A9N61526
10 A A9N61508 A9N61528
13 A A9N61509 A9N61529
15 A A9N61510 A9N61530
16 A A9N61511 A9N61531
20 A A9N61512 A9N61532
25 A A9N61513 A9N61533
30 A A9N61514 A9N61534
32 A A9N61515 A9N61535
40 A A9N61517 A9N61537
50 A A9N61518 A9N61538
63 A A9N61519 A9N61539
Number of modules of 2 4
9 mm
Accessories See pagess E-8 and E-15

Acti 9 | Catalogue 2014 A-35


DC circuit supplementary C60H-DC (cont.)
protectors for feeders / C curve
distribution systems

Connection Without accessory With accessories


Rating Tightening Copper cables 50 mm² Screw-on Multi-cables
DB123537

torque Al connection for terminal


14 mm terminal ring terminal Rigid
6.5 mm Rigid / Flexible or Flexible
Stranded ferrule cables cables
PZ2

DB118787
DB122945

DB122946

DB122935

DB118789
F
O-OF
F
O-OF

y 25 A 2.5 N.m 1 to 25 mm2 1 to 16 mm2 50 mm2 Ø 5 mm 3 x 16 mm2 3 x 10 mm2


> 25 A 3.5 N.m / 1 to 35 mm2 1 to 25 mm2 -

Multi-cables connection Without accessory


Rating Tightening 2 Copper cables 3 Multi-cables / Different wires
DB123537

torque Rigid / Flexible or Flexible / Stranded Flexible / Stranded /


14 mm Stranded ferrule Rigid
6.5 mm
DB122946
DB122945

DB118787
PZ2

F
O-OF
F
O-OF

y 25 A 2.5 N.m 2 x 1 mm2 to 2 x 10 mm2 3 x 1 mm2 2 x 2.5 mm2 + 1 x 1.5 mm2


> 25 A 3.5 N.m 2 x 1 mm2 to 2 x 16 mm2 3 x 4 mm2 2 x 10 mm2 + 1 x 6 mm2

Technical data
DB123310

b Tripping curves: C curve - Overcurrent protection for any type of application.


b Positive break indication - the green strip indicates that all the poles are open and
allows work to be carried out on the downstream circuit in complete safety.
b Suitable for isolation as defined in IEC / EN 60947-2.
b Increase in the service life of the product: thanks to fast closure independent of the
speed of action on the handle.
Clip on DIN rail 35 mm. b Current limitation in the event of a fault: fast opening of the contacts prevents the
loads from being destroyed in the event of a short-circuit.
DB123312

Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 500 V DC
Rated voltage (Un) 1P 250 V DC
2P 500 V DC
Pollution degree 3
Rated impulse withstand voltage (Uimp) under 6 kV
Indifferent position of installation. frame
Magnetic tripping (Ii) 8.5 In (± 20 %) (compatible with curve C)
Additional characteristics
IP20 IP40
DB123314

Degree of protection Device only IP20


(IEC 60529) Device in modular IP40
enclosure
Utilization category A (no delay in accordance with IEC/EN 60947-2
standards)
Endurance (O-C) Electrical 3,000 cycles (where L/R=2 ms)
6,000 cycles where the circuit is resistive
Mechanical 20,000 cycles
Tropicalization (IEC 60068-2) Treatment 2 (relative humidity 95 % at 55°C
Operating temperature -25°C to 70°C
Storage temperature -40°C to 85°C

d
Failure to match polarity during connection may lead to a fire hazard
and/or serious injury.
b The connection polarity must be observed (marked on the front panel).
PB124305.eps

b Use only with direct current.

A-36 Acti 9 | Catalogue 2014


DC circuit supplementary C60H-DC (cont.)
protectors for feeders / C curve
distribution systems

Weight (g)
Circuit-breaker
Type C60H-DC
1P 128 g
2P 256 g

DB124113 Dimensions (mm)

C60H-DC

10 10
DB124112

t 35

t
35

t
Details of minimum distance between circuit-breaker
and earthed metal parts for circuit-breaker intended for
use without enclosure.

Acti 9 | Catalogue 2014 A-37


Protection iC60L circuit breakers
Motor protection
instantaneous circuit breakers
(ICB) (curve MA)
PB104434-40

b Insulated terminals IP20

Visi-trip window
b Fault tripping is indicated by a red
mechanical indicator on the front face

b Large circuit
labelling area
Positive contact indication
b Suitable for industrial isolation according to
IEC/EN 60947-2 standard.
b The presence of the green strip guarantees
physical opening of the contacts and allows
operations to be performed on the downstream
circuit in complete safety

b Double clip for


dismounting with comb
busbar in place

b Increased product service life thanks to:


v overvoltage resistance by high level of industrial performances conception
(pollution degree, rated impulse withstand voltage and insulation voltage),
v high performance limitation (see limitation curves),
v fast closing independent of the speed of actuation of the toggle.
b Remote indication, open/closed/tripped, by optional auxiliary contacts.
b Top or bottom electrical feeding.

(1) Information to be provided by the country.

A-38 Acti 9 | Catalogue 2014


Protection iC60L circuit breakers
Motor protection
instantaneous circuit breakers
(ICB) (curve MA) (cont.)
IEC/EN 60947-2
DB116619

A
b iC60L curve MA circuit breakers combine the following functions:
v circuit protection against short-circuit currents,
PB104443-40

PB104448-40

v suitability for industrial isolation according to IEC/EN 60947-2, standard,


v fault tripping indication by a red mechanical indicator in circuit breaker front face,
v to be associated with overload protection for motor.

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
capacity (Ics)
Ph/Ph (2P, 3P) 220 to 240 V 380 to 415 V 440 V
Rating (In) 1.6 to 16 A 40 kA 20 kA 15 kA 50 % of Icu
25 à 40 A 30 kA 15 kA 10 kA 50 % of Icu

Catalogue numbers
iC60L instantaneous trip circuit breaker
Type 2P 3P
1 3 1 3 5

2 4 2 4 6

Auxiliaries see pages E-2 and F-2 see pages E-2 and F-2
Vigi iC60 see page B-17 see page B-17
Rating (In) Quality label (1) Curve MA Curve MA
1.6 A A9F90272 A9F90372
2.5 A A9F90273 A9F90373
4A A9F90204 A9F90304
6.3 A A9F90276 A9F90376
10 A A9F90210 A9F90310
12.5 A A9F90282 A9F90382
16 A A9F90216 A9F90316
25 A A9F90225 A9F90325
40 A A9F90240 A9F90340
Width in 9-mm modules 4 6
Accessories See pages E-2 and E-10 See pages E-2 and E-10

Acti 9 | Catalogue 2014 A-39


Protection iC60L circuit breakers
Motor protection
instantaneous circuit breakers
(ICB) (curve MA) (cont.)
Connection Without accessory With accessories
Rating Tightening Copper cables 50 mm² Screw-on Multi-cables terminal
DB123060

torque Rigid Flexible Al connection Rigid Flexible


14 mm
6.5 mm or ferrule terminal for ring cables cables
terminal
PZ2

DB122945

DB122946

DB122935

DB118789

DB118787
1.6 to 16 A 2 N.m 1 to 25 mm2 1 to 16 mm2 - Ø 5 mm - -
25 to 40 A 3.5 N.m 1 to 35 mm2 1 to 25 mm2 50 mm2 3 x 16 mm2 3 x 10 mm2

Technical data
DB123310

Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 500 V AC
Pollution degree 3
Rated impulse withstand voltage (Uimp) 6 kV
Thermal tripping Reference temperature 50 °C
Clip on DIN rail 35 mm. Temperature derating See the Technical Guide
Magnetic tripping MA curve 12 In ± 20 %
Utilization category A
DB123312

Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
enclosure Insulation classe II
Endurance (O-C) Electrical 10,000 cycles
Mechanical 20,000 cycles
Indifferent position of installation. Overvoltage category (IEC 60364) IV
Operating temperature -35°C to +70°C
Storage temperature -40°C to +85°C
IP20 IP40
DB123314

Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95 % to 55°C)

Dimensions (mm) Weight (g)


Circuit-breaker
DB124053

78.5
69.5 Type iC60L
3P 54 50 2P 250
2P 36 5.5
3P 375

4.4

94 85 45

64
4.6

A-40 Acti 9 | Catalogue 2014


Protection NG125LMA circuit breakers
Motor protection
(curve MA)

3P 80 A
b Voltage taps:
v auxiliaries power supply
v measurement
v emergency stop
v remote reporting

b Cable strength:
v ribbed cage
A
b Padlocking in position:
v terminal depth O or I, manual control is inhibited,
v tightening by Allen tripping is enabled
hex key (NG125 80 A)
056918N_SE-90

b Test button to check


satisfactory operation of
the tripping mechanism

3P 3P
b Pull-out strength:
b Integrated padlocking
v metallic lock
device

b Central manual control, 3


b Impact and vibration resistance: positions:
v high-strength enclosure v ON
v IK 05 v tripped on fault
v open

b Circuit breaker tripped indicator

b Electric power supply


through the top or bottom
b Positive contact indication:
DB123493

v suitability for isolation in the industrial sector to IEC/EN 60947-2


v the presence of the green strip guarantees that the contacts open physically
and allows work to be carried out safely on the downstream circuit

b Longer product service life due to:


v good overvoltage withstand capacity,
v high limitation performances,
v fast closure independent of the speed of actuation of the toggle.

Acti 9 | Catalogue 2014 A-41


Protection NG125LMA circuit breakers
Motor protection
(curve MA) (cont.)

IEC/EN 60947-2
DB116619

b NG125LMA circuit breakers are circuit breakers which combine the following
functions:
v circuit protection against short-circuit currents,
v circuit protection against overload currents,
v suitability for isolation in the industrial sector to IEC/EN 60947-2,
v tripping upon fault is indicated by a red mechanical state indicator light on the front
face of the circuit breaker.
056924_SE-28

056939_SE-28

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) to IEC/EN 60947-2 Service
Voltage (Ue) breaking
Ph/Ph (2P, 3P) 220 to 240 V 380 to 415 V 440 V 500 V capacity
(Ics)
Rating (In) 4 to 80 A 100 kA 50 kA 40 kA 15 kA 75 % of Icu
(trip units)

NG125LMA 2P NG125LMA 3P

Catalogue numbers
NG125LMA circuit breaker
Type 2P 3P
1 3 1 3 5
DB123810

DB123811

2 4 2 4 6

Auxiliaries see page F-14 – Vigi NG125 add-on residual


current device, see page B-27
Rating (In) Quality label Magn. I (A) Curve MA Curve MA
(1)

4A 50 18868 18879
6.3 A 75 18869 18880
10 A 120 18870 18881
12.5 A 150 18871 18882
16 A 190 18872 18883
25 A 300 18873 18884
40 A 480 18874 18885
63 A 750 18875 18886
80 A 960 18876 18887
Width in 9 mm modules 6 9
Accessories See page E-26

(1) Information to be supplied by the country concerned.

A-42 Acti 9 | Catalogue 2014


Protection NG125LMA circuit breakers
Motor protection
(curve MA) (cont.)

Connection Without With


accessories accessories
Rating Tightening Copper cables 70 mm2 Screw-on Small ring Multi-cable
DB122863

NG125
80 A torque Al connection terminal terminal
20 mm
Rigid Flexible or terminal for ring Rigid Flexible
with terminal cables cables
ferrule
A

DB122945

DB122946

DB123410

DB123488

DB118789

DB118787
PZ2 6 mm
6.5 mm
NG125 4 to 63 A 3.5 N.m 1.5 to 50 mm2 1 to 35 mm2 - - - 3 x 16 mm2 3 x 10 mm2
y 63 A 80 A 6 N.m 16 to 70 mm2 10 to 50 mm2 25 to 70 mm2 2 x 35 mm2 1 x 70 mm2
1 x 50 mm2
b On 3P 80 A: upstream voltage taps for each pole, by 6.35 mm Fast-on terminal.

Technical data
DB123310

Main characteristics
According to IEC/EN 60947-2
Insulation voltage (Ui) 690 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 8 kV
Thermal Reference 40°C
tripping temperature
Clips on to 35 mm DIN rail.
Magnetic MA curve 12 In ± 20 %
tripping (Ii)
Utilization category A
DB123312

Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
enclosure
Endurance (O-C) Electrical 10,000 cycles
Mechanical 20,000 cycles
Operating temperature -30°C to +70°C
Any installation position.
Storage temperature -40°C to +70°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95 % at 55°C)
IP20 IP40
DB123314

Weight (g)
Circuit breaker
Type NG125LMA
2P 480
3P 720

Dimensions (mm)
DB122862

DB123490

27.75 25.5 27.75

16.25

70.5

16.25

53.25

Spacing for mounting on panel

Acti 9 | Catalogue 2014 A-43


Circuit protection STI isolatable fuse-carriers
Tertiary sector, Industry

PB110044-40
PB110043-40

STI Cartridges
IEC/EN 60947-3, IEC 60269-1, IEC 60269-2,
IEC/EN 60269-2 NF C 60-200-2

b The STI isolatable fuse-carriers provide overload and short-circuit protection.


PB110046-40
PB110045-40

b They are used for industrial applications requiring a high breaking capacity.
b They perform the isolation function and must not be used as switches.
b To be equiped with aM or gG (gL - gl) type fuse cartridge without striker, with or
without fuse blowing indicator.
b Isolation of all poles is guaranteed for the 2P, 3P, and 3P+N versions during
factory assembly.
The general purpose fuse (gG fuse) provides overload and short-circuit protection.
The fuse for motor application (aM fuse) only provides short-circuit protection.
It is used for protection of loads with a high peak current (motors, transformer
primaries, etc.).
PB110047-28

Catalogue numbers
Fuse cartridge (Type F) STI fuse holder
Type Network type
Rating Voltage Short-circuit current
rating (Ue) (Isc)
aM gG aM gG 1P 1P+N (1) 2P 3P 3P+N (1)
PB102098-20

N 1 1 3 1 3 5 N 1 3 5
DB112797

DB112798

DB112799

DB112800

DB110801

2 2 4 2 4 6 2 4 6
2
8.5 x 31.5 2A 400 V AC 20 kA 20 kA DF2BA0200 DF2BN0200 A9N15635 A9N15645 A9N15650 A9N15655 A9N15657
mm 4A 400 V AC 20 kA 20 kA DF2BA0400 DF2BN0400
6A 400 V AC 20 kA 20 kA DF2BA0600 DF2BN0600
8A 400 V AC 20 kA 20 kA DF2BA0800 DF2BN0800
10 A 400 V AC 20 kA 20 kA DF2BA1000 DF2BN1000
10.3 x 38 2A 500 V AC 120 kA 120 kA DF2CA02 DF2CN02 A9N15636 A9N15646 A9N15651 A9N15656 A9N15658
mm 4A 500 V AC 120 kA 120 kA DF2CA04 DF2CN04
6A 500 V AC 120 kA 120 kA DF2CA06 DF2CN06
10 A 500 V AC 120 kA 120 kA DF2CA10 DF2CN10
16 A 500 V AC 120 kA 120 kA DF2CA16 DF2CN16
20 A 500 V AC 120 kA 120 kA DF2CA20 DF2CN20
25 A 400 V AC 120 kA 120 kA DF2CA25 DF2CN25

(1) The neutral pole comes equipped with a locked tube.

A-44 Acti 9 | Catalogue 2014


Circuit protection STI isolatable fuse-carriers
Tertiary sector, Industry
(cont.)

230 V neon indicator light Padlocking device


(Option) b Locks the toggle in the "open" or "closed"
b Indicates fuse blowing (off in normal position. Used with an 8 mm max. diameter
operation and lit red after fuse blowing) padlock (not supplied):
b 400 V maxi v only one padlock for 1P, 1P+N and 2P
products(on the left pole)
v and two padlock on the 3P and 3P+N
products (on every extremity)
PB110050-50

1P+N, 3P+N
b Phase opening causes compulsory
opening of the neutral
b The phase opens before the neutral
on isolation and closes after the neutral
on circuit closing
b Small dimensions
v 1P+N in 18 mm
v 3P+N in 54 mm Fuse-carrier
b Captive
b Additional housing is provided for a
spare fuse
Clip-on markers
b Used to identify:
v either on the front face
v or on the downstream terminals

Connection Without accessory With accessories


Type Rating Tightening Copper cables Screw-on connection for
DB123241

torque Rigid Flexible ring terminal


12 mm or ferrule
5.5 mm
DB122945

DB122946

DB118789

STI All 2 N.m 0.75 to 10 mm2 0.5 to 6 mm2 Ø 5 mm


PZ2 2 x 0.75 mm2 to 2 x 4 mm2 2 x 0.5 mm2 to 2 x 4 mm2
DB123325

1 Screw-on connection for ring terminal 27053

2 1

Mounting accessories
2 Comb busbar See module LIN001
3 Padlocking device 15669
4 Neon indicator light 1 piece blister 15668
3 4 5
5 Clip-on terminal markers See module CA907012

Acti 9 | Catalogue 2014 A-45


Circuit protection STI isolatable fuse-carriers
Tertiary sector, Industry
(cont.)

Technical data
DB123309

Main characteristics
Insulation voltage (Ui) 500 V
Breaking capacity according to IEC 60269-2 ≤ 400 V 50 kA
Pollution degree 3
Operating frequency (Hz) 50/60
Clip on DIN rail 35 mm.
Additional characteristics
Degree of protection Device in modular enclosure IP40
Insulation classe II
Operating temperature -20°C to +60°C
Storage temperature -40°C to +80°C
Maximum dissipated power per pole of STI isolatable fuse-carriers
Fuse cartridge type Ith Pmax
8.5 x 31 mm aM 10 A 2.5 W
gG 20 A 2.5 W
10.3 x 38 mm aM 16 A 3W
gG 25 A 3W
IP40
DB123391

Maximum dissipated power per fuse cartridges


Fuse cartridge type Ith Pmax
8.5 x 31 mm aM 2 to 10 A 0.9 W
gG 2 to 10 A 2.5 W
10.3 x 38 mm aM 2 to 25 A 1.2 W
gG 2 to 25 A 3W

Dimensions (mm)
3P / 3P+N 54
DB122933

2P 36
1P / 1P+N 18 5.5 44 16

81 35 45

STI

A
aM, gG fuse cartridge
DB122934

C Type A B C
8.5 x 31.5 mm 8.5 31.5 10.3
B 10.3 x 38 mm 10.3 38 10.5

aM, gG

A-46 Acti 9 | Catalogue 2014


Residual
Current Devices

Acti 9 | Catalogue 2014 B-1


Protection Choice of earth leakage
Earth leakage protection
protection devices

Choice of sensitivity
The sensitivity of an earth leakage protection device depends mainly on the function it has to perform:
b Protection from electric shock by direct contact.
b Protection from electric shock by indirect contact.
b Protection from fire due to current leakage.
The following table gives a reminder of:
b The circuits that must be protected against these various risks (obligation or recommendation).
b The type of earth leakage protection device to be used in each case, its sensitivity, and its location in the distribution diagram.

Type of Obligations Recommended Sensitivity (IΔn)


protection by
International standard IEC 60364 Schneider 30 mA (*) 100 mA to 3000 mA 300 mA (or 500 mA)
(depending on the earthing
Electric system)
Protection from electric shock by direct contact
Power supply for b Lighting in the home Setup in final
b General-purpose power sockets, distribution
DB123167

up to 20 A switchboard
b Appliances in the vicinity of a b Residual current
bathtub, shower, pond or swimming device protecting a
pool circuit
b Portable appliances for outdoor
use, up to 32 A b Residual current
b Lighting for exhibition stands and circuit breaker
shows protecting a group of
b Outdoor lighting circuits

To be modified according to
national obligations (above)
Protection from electric shock by indirect contact
The entire power distribution – Setup in final distribution
system, except for devices: switchboard
DB123168

b With class II insulation b Residual current circuit


b Operating at Safety Extra Low breaker or device, on
Voltage (class III) incoming feeder
To be modified according to Setup in subdistribution
national obligations (above) board or main
switchboard
b Residual current device
protecting a circuit
b Residual current device
or circuit breaker
protecting a group of
circuits
b On incoming feeder:
residual current circuit
breaker or device
Protection from fire due to current leakage
b High-risk premises: b Dilapidated Setup in final distribution
v explosion (BE3) buildings or electrical switchboard
v fire (BE2) installations b Residual current circuit
b Agricultural and b Humid breaker or device, on
horticultural buildings atmospheres: incoming feeder
b Equipment for fairs, exhibitions agricultural buildings,
and shows public swimming pools Setup in subdistribution
DB123169

b Temporary outdoor recreational b Presence of board or main


installations chemical agents switchboard
b Residual current device
To be modified according to
protecting each circuit to a
national obligations (above)
high-risk zone
b Residual current device
or circuit breaker protecting
a group of circuits
b On incoming feeder:
residual current circuit
breaker or device

(*) The 10 mA sensitivity is useful for certain very specific applications, where there is a risk that someone could sustain a non-dangerous current (10 to 30 mA)
without being able to get free. Example: healthcare equipment for hospital beds. Generally, devices with this very high sensitivity are liable to cause frequent
tripping, due to the natural leakage currents of the installation.

B-2 Acti 9 | Catalogue 2014


Protection Choice of earth leakage
Earth leakage protection
protection devices (cont.)

Interference immunity
Schneider Electric provides various equipment technologies capable of overcoming the consequences of interference of all kinds.

Operating conditions Examples Types


AC A SI B

Loads
With no special characteristics b General-purpose power sockets b b b b
DB123165

b Incandescent lighting
b Household appliances: microwave oven, dishwasher,
clothes dryer
b Electric heating, water heater
Including a Single phase b Household appliances: induction cooking appliances, washing – b b –
rectifier machines (variable speed)
b Single-phase variable speed drives
Three phase b Three-phase variable speed industrial drives – – – b
b Three-phase uninterruptible power supplies
Generating high-frequency b Fluorescent lighting powered by extra low voltage transformer, – – b b
interference (current peaks, by electronic ballast
harmonics) b Variable luminosity lighting
b Powerful IT equipment
b Single-phase variable speed industrial drives
b Air conditioning
b Telecommunications equipment
b Capacitor banks
Including an anti-harmonic filter b Microcomputer systems – – b b
in the power supply b Computer peripherals (printers, scanners, etc.)
Electrical environment
Vicinity of equipment generating b High-powered switching devices – – b b
transient overvoltages b Reactive energy compensation banks
DB123166

Circuits powered by an b Backed-up networks – – b b


uninterruptible power supply
"Isolated neutral" (IT) earthing – – – b b
system
Major risk of lightning strokes b Buildings protected by a lightning protection system – – b b
b Mountainous or humid regions
b Regions with high keraunic level

B
Atmosphere
Ambient temperature which – – b b b
could be less than -5°C
DB123164

Presence of corrosive agents b Indoor swimming pools – – b (1) –


(AF2 to AF4) or dust b Yacht harbours, marinas, camping grounds
b Water treatment
b Chemical industries, heavy industries, paper mills
b Mines and cellars, road tunnels
b Markets, stock raising, food processing industries
(1) SiE for C120 and NG125 circuit-breakers

Discrimination
Residual current devices of average sensitivity (100 mA and more) are available in a selective (s) and delayed (R) version.
This option ensures that, in the event of an earth fault downstream of the installation, only the defective part is switched off.
The table below shows (in green) which upstream/downstream equipment combinations provide this discrimination.
Sensitivity (mA) - Upstream
Instantaneous Selective s Delayed R
Sensitivity (mA) - Downstream 30 100 300 500 1000 3000 100 300 500 1000 3000 1000 3000
Instantaneous 30 - - - - - -
DB123476

100 - - - - - - -
300 - - - - - - - - -
s or R
500 - - - - - - - - - - -
1000 - - - - - - - - - - -
3000 - - - - - - - - - - - - -
Selective s 100 - - - - - - - - - - -
300 - - - - - - - - - - - -
500 - - - - - - - - - - - -
1000 - - - - - - - - - - - -
3000 - - - - - - - - - - - - -
Delayed R 1000 - - - - - - - - - - - - -
3000 - - - - - - - - - - - - -

Acti 9 | Catalogue 2014 B-3


Protection Overview of the earth leakage
Earth leakage protection
protection product range

Selection guide
Type Residual current circuit breakers

iID K iID RCCB-ID 125 A RCCB-ID type B

PB104497-35

PB104472-35

62074_SE-35

PB101616_SE-35
Standards IEC/EN 61008 IEC/EN 61008 IEC/EN 61008-1 and VDE 0664 IEC/EN 61008 and VDE 0664
Number of poles 1P+N – – – –
2P b b b –
3P – – – –
4P b b b b
Type AC b b b –
A – b b –
SI – b b –
B – – – b
Voltage (V) Ue 230/400 230/400 230/400 230/400
Impulse voltage (kV) Uimp 4 6 4 4
Insulation voltage (V) Ui 440 500 400 400
Current rating (A) In 25 - 40 - 63 16 to 100 125 25 to 125

Frequency (Hz) 50/60 50 50 50


Rated breaking capacity (A) Icn – – 10000 –
Rated conditional Inc 4500 10000 10000 10000
short-circuit current
Rated residual breaking and (IDm) 10 In (500 A min.) 1500 1250 10 In (500 A min.)
making capacity (A)
Curve – – – –
Sensitivity (mA) (IDn) 10 – b – –
30 b b b b
100 – b b –
300 b b b b
500 – b b b
1000 – – – –
3000 – – – –
300 s – b b b
500 s – b – –
1000 s – – – –
3000 s – – – –
Electrical characteristics
Curves B – – – –
C – – – –
D – – – –
L – – – –
K – – – –
MA – – – –
For more details, see page B-11 B-6 B-13 B-15
Accessories – E-2, E-10 B-13 B-15
Auxiliaries – E-2, F-2 B-13 B-15

Inc: rated conditional short-circuit current


Value of the alternating component of the prospective current that a residual current circuit breaker protected by an appropriate short-circuit protective device
(SCPD) mounted in series can withstand in specified conditions of use.

IΔc: rated residual short-circuit current


Value of the alternating component of the prospective residual current that a residual current circuit breaker protected by an appropriate short-circuit protective
device (SCPD) mounted in series can withstand in specified conditions of use.

B-4 Acti 9 | Catalogue 2014


Protection Overview of the earth leakage
Earth leakage protection
protection product range
(cont.)

Add-on residual current devices Residual current


devices RCBO
Vigi iC60 Vigi C120 Vigi NG125 Vigi iDPN iDPNa Vigi iDPN N/H Vigi
PB104466-40

PB107924-40

PB103998-40

PB107115-32

PB104341B-35

PB104341B-35
IEC/EN 61009 IEC/EN 61009 IEC/EN 61009 IEC/EN 61009 IEC/EN 61009 IEC/EN 61009
– – – b b b
b b b – – –
b b b b – –
b b b b – –
b b b b b b
b b b b b b
b b b b – b
– – – – – –
230/400 230/400 230/400 230/400 230 230
6 6 8 6 4 4
500 500 690 500 400 400
25 - 40 - 63 10 - 125 63 - 125 25 - 63 6 to 40 N= 4 to 40
H= 6 to 32
50/60 50/60 50/60 50/60 50/60 50/60
– – – – 4500 6000/10000
– – – – – –

– – – – 4500 6000

– – – – B, C B, C
b – – – b –
b b b b b b

B
b – – b – –
b b b b b b
b b b – – –
– – b – – –
– – b – – –
b b b – – –
b b b – – –
b b b – – –
– – b – – –

Depending on circuit Depending on circuit breaker Depending on circuit breaker used Depending on circuit breaker – b
breaker used used b b
used – –
– –
– –
– –
B-17 B-22 B-27 B-33 B-35 B-36
E-2 E-7 and E-15 E-26 E-29 E-6, E-10 & E-29 E-6, E-10 & E-29
E-2 E-7 and F-9 F-14 E-31 F-2 F-2

Im: rated making and breaking capacity


Value of the alternating component of the prospective current that a residual current circuit breaker is capable of establishing or interrupting in specified conditions
of use.

IΔm: rated making and breaking capacity


Value of the alternating component of the prospective residual current that a residual current circuit breaker is capable of establishing and withstanding during its
opening time and interrupting in specified conditions of use and behaviour.

SCPD
Short-circuit protective device (a fuse in the case of our markings): this is the max. fuse that can be used to resist the value Inc = IΔc.

Acti 9 | Catalogue 2014 B-5


Protection iID residual current
Earth leakage protection
circuit breakers (AC, A, SI types)
(cont.)
PB104548-40

b Insulated terminals IP20


PB104472-40

b Test button

Visi-trip window
b Fault tripping is indicated by a red
mechanical indicator on the front face

b Large circuit labelling area

Positive contact indication


b Suitable for industrial isolation according to
IEC/EN 60947-3 standard
b The presence of the green strip guarantees
physical opening of the contacts and allows
operations to be performed on the downstream
circuit in complete safety
b Double clip for
dismounting with comb
busbar in place

SI type
The SI type provides increased immunity from electrical interference and polluted or
corrosive environments.

B-6 Acti 9 | Catalogue 2014


Protection iID residual current
Earth leakage protection
circuit breakers (AC type)

IEC/EN 61008-1
DB116619

b The iID residual current circuit breakers provide:


PB104472-40

PB104473-40

v protection of persons against electric shock by direct contact (y 30 mA),


v protection of persons against electric shock by indirect contact (u 100 mA),
v protection of installations against the risk of fire (300 mA or 500 mA).

Catalogue numbers
iID residual current circuit breakers
Type AC Width in 9 mm
Product iID module
Auxiliaries See page E-2 and F-2
2P Sensitivity 10 mA 30 mA 100 mA 300 mA 500 mA 300 mA s 500 mA s
Rating 16 A A9R10216 - - - - - - 4

B
DB122476

25 A A9R10225 A9R71225 - A9R74225 A9R16225 - -


40 A - A9R71240 A9R12240 A9R74240 A9R16240 - -
63 A - A9R71263 A9R12263 A9R74263 A9R16263 A9R15263 -
80 A - A9R11280 A9R12280 A9R14280 - A9R15280 -
100 A - A9R11291 A9R12291 A9R14291 - A9R15291 -

4P Sensitivity 10 mA 30 mA 100 mA 300 mA 500 mA 300 mA s 500 mA s


Rating 25 A - A9R71425 - A9R74425 A9R16425 - - 8
DB122477

40 A - A9R71440 A9R12440 A9R74440 A9R16440 A9R15440 A9R17440


63 A - A9R71463 A9R12463 A9R74463 A9R16463 A9R15463 A9R17463
80 A - A9R11480 A9R12480 A9R14480 A9R16480 A9R15480 A9R17480
100 A - A9R11491 A9R12491 A9R14491 - A9R15491 -

Voltage rating (Ue) 2P 230 - 240 V


4P 400 - 415 V
Operating frequency 50/60 Hz
Accessories See pages E-2 and E-10

Acti 9 | Catalogue 2014 B-7


Protection iID residual current
Earth leakage protection
circuit breakers (A type)

IEC/EN 61008-1
DB116619

b The iID residual current circuit breakers provide:


PB104472-40

PB104473-40

v protection of persons against electric shock by direct contact (y 30 mA),


v protection of persons against electric shock by indirect contact (u 100 mA),
v protection of installations against the risk of fire (300 mA or 500 mA).

Catalogue numbers
iID residual current circuit breakers
Type A Width in 9 mm
module
Product iID
Auxiliaries See page E-2 and F-2
2P Sensitivity 10 mA 30 mA 100 mA 300 mA 500 mA 300 mA s
Rating 16 A A9R20216 - - - - - 4
DB122476

25 A A9R20225 A9R21225 - A9R24225 - -


40 A - A9R21240 - A9R24240 - A9R25240
63 A - A9R21263 - A9R24263 - A9R25263
100 A - A9R21291 - A9R24291 - A9R25291

4P Sensitivity 10 mA 30 mA 100 mA 300 mA 500 mA 300 mA s


Rating 25 A - A9R21425 - A9R24425 - - 8
DB122477

40 A - A9R21440 A9R22440 A9R24440 A9R26440 A9R25440


63 A - A9R21463 A9R22463 A9R24463 A9R26463 A9R25463
80 A - A9R21480 - A9R24480 - A9R25480
100 A - A9R21491 - A9R24491 A9R26491 A9R25491

Voltage rating (Ue) 2P 230 - 240 V


4P 400 - 415 V
Operating frequency 50/60 Hz
Accessories See pages E-2 and E-10

B-8 Acti 9 | Catalogue 2014


Protection iID residual current
Earth leakage protection
circuit breakers (SI type)

IEC/EN 61008-1
DB116619

b The iID residual current circuit breakers provide:


PB104472-40

PB104473-40

v protection of persons against electric shock by direct contact (y 30 mA),


v protection of persons against electric shock by indirect contact (u 300 mA),
v protection of installations against the risk of fire (300 mA or 500 mA).

The SI type provides increased immunity from electrical interference and polluted or
corrosive environments.

Catalogue numbers
iID residual current circuit breakers
Type SI Width in 9 mm
module
Product iID
Auxiliaries See page E-2 and F-2
2P Sensitivity 10 mA 30 mA 300 mA 300 mA s 500 mA s
Rating 16 A - - - - - 4

B
DB122476

25 A A9R30225 A9R61225 - - -
40 A - A9R61240 - A9R35240 -
63 A - A9R61263 - A9R35263 -
100 A - - - A9R35291 -

4P Sensitivity 10 mA 30 mA 300 mA 300 mA s 500 mA s


Rating 25 A - A9R61425 - - - 8
DB122477

40 A - A9R61440 - A9R35440 A9R37440


63 A - A9R61463 A9R34463 A9R35463 A9R37463
80 A - A9R31480 - A9R35480 A9R37480
100 A - A9R31491 A9R34491 A9R35491 -

Voltage rating (Ue) 2P 230 - 240 V


4P 400 - 415 V
Operating frequency 50/60 Hz
Accessories See pages E-2 and E-10

Acti 9 | Catalogue 2014 B-9


Protection iID residual current
Earth leakage protection
circuit breakers (AC, A, SI types)

Connection Without accessory With accessories*


Type Tightening Copper cables 50 mm² Screw-on Multi-cables terminal
DB122947

torque Rigid Flexible Al connection Rigid Flexible


14 mm or ferrule terminal for ring cables cables
6.5 mm
terminal
PZ2

DB122945

DB122946

DB122935

DB118789

DB118787
iID 3.5 N.m 1 to 35 mm2 1 to 25 mm2 50 mm2 Ø 5 mm 3 x 16 mm2 3 x 10 mm2
* See page E-2

Technical data
DB123310

Main characteristics
Insulation voltage (Ui) 500 V
Pollution degree 3
Rated impulse withstand voltage (Uimp) 6 kV
According to IEC/EN 61008-1
Making and breaking capacity (Im/IDm) 1500 A
Clip on DIN rail 35 mm.
Surge current AC and A types (no selective s) 250 Â
withstand (8/20 μs) AC, A types (selective s) 3 kÂ
DB123312

without tripping
SI type 3 kÂ
Conditional rated With iC60N/H/L Equal to breaking capacity of iC60
short circuit current With fuse 10,000 A
(Inc/IDc)
Additional characteristics
Degree of protection Device only IP20
Indifferent position of installation. Device in modular enclosure IP40
Insulation classe II
Endurance (O-C) Electrical (AC1) 16 to 63 A 15,000 cycles
IP20 IP40
DB123314

80 to 100 A 10,000 cycles


Mechanical 20,000 cycles
Operating AC type -5°C to +60°C
temperature
A and SI types -25°C to +60°C
Storage temperature -40°C to +85°C

Weight (g)
Residual current circuit breakers
Type iID
2P 210
4P 370

Dimensions (mm)
4P 72 69
DB122775

2P 36 5.5 44 20

96 85 45

B-10 Acti 9 | Catalogue 2014


Protection iID K residual current
Earth leakage protection
circuit breakers

IEC/EN 61008-1
DB116619

b The iID K residual current circuit breakers provide:


v protection of persons against electric shock by direct contact (30 mA),
v protection of persons against electric shock by indirect contact (300 mA)
PB104497-40

PB104498-40

v protection of installations against the risk of fire (300 mA).

Catalogue numbers
iID K residual current circuit breakers
Type AC Width in 9-mm
modules
Product iID K
Auxiliaries Without auxiliaries
2P Sensitivity 30 mA 300 mA
Rating 25 A A9R50225 A9R75225 4
DB122476

40 A A9R50240 A9R75240

4P Sensitivity 30 mA 300 mA
Rating 25 A A9R50425 A9R75425 8
DB122477

40 A A9R50440 A9R75440
63 A A9R70463 A9R75463

B
Voltage rating (Ue) 2P 230 - 240 V
4P 400 - 415 V
Operating frequency 50/60 Hz
PB104497-40

b Double clip for


dismounting with comb
busbar in place
b Test button

b Padlocking device

b Large circuit labelling area

Acti 9 | Catalogue 2014 B-11


Protection iID K residual current
Earth leakage protection
circuit breakers (cont.)

Connection Without accessory


Type Tightening Copper cables

DB122947
torque Rigid Flexible or
16 mm ferrule
6.5 mm

DB122945

DB122946
PZ2

iID K 3.5 N.m 1 to 35 mm2 1 to 25 mm2

Technical data
DB123310

Main characteristics
According to IEC/EN 61008-1
Insulation voltage (Ui) 440 V
Pollution degree 2
Rated impulse withstand voltage (Uimp) 4 kV
Clip on DIN rail 35 mm. Making and breaking 25 to 40 A 500 A
capacity (Im/IDm) 63 A 630 A
Surge current withstand (8/20 μs) without tripping Up to 200 Â
DB123312

Conditional rated With iC60N/H/L, iK60N 6000 A


short circuit current With fuse 4500 A
(Inc/IDc)
Additional characteristics
Degree of protection Device in modular enclosure IP40
Endurance (O-C) Electrical 2000 cycles (AC1)
Mechanical 5000 cycles
Indifferent position of installation.
Operating temperature -5°C to +60°C
Storage temperature -40°C to +85°C

IP40
DB123391

Weight (g)
Residual current circuit breakers
Type iID K
2P 210
4P 370

Dimensions (mm)
4P 72 69
DB122775

2P 36 5.5 44 20

96 85 45

B-12 Acti 9 | Catalogue 2014


Protection RCCB-ID 125 A residual current
Earth leakage protection
circuit breaker (AC, A, SI types)

IEC/EN 61008-1, VDE 0664

b The RCCB-ID 125 A residual current circuit breakers provide:


62074_SE-35

PB107510-33
62252_SE-35

v protection of persons against electric shock by direct contact (30 mA),


v protection of persons against electric shock by indirect contact (u 100 mA),
v protection of installations against the risk of fire (300 mA or 500 mA).

The SI type provides increased immunity from electrical interference and polluted or
corrosive environments.

OFsp auxiliary
b Electrical indication: by OFsp auxiliary mounted to the left, it has a double
changeover switch indicating the "open" or "closed" position of the RCCB-ID 125 A.
16973 16921 16940
Accessories
b 2P and 4P sealable screw shield.
PB100572-18
PB100573-18

16938 16939

Catalogue numbers
RCCB-ID 125 A residual current circuit breakers
Type AC A SI Width in 9 mm
module
2P Sensitivity 30 mA 100 mA 300 mA 500 mA 30 mA 300 mA 300 mA s 500 mA 30 mA 300 mA
Rating 125 A 16966 - 16967 - 16970 16971 - - 16972 16973 4
E91413

N
1 3

B
T

R
2 4
N
4P Sensitivity 30 mA 100 mA 300 mA 500 mA 30 mA 300 mA 300 mA s 500 mA 30 mA 300 mA
N Rating 125 A 16905 16906 16907 16908 16924 16926 16925 16927 16920 16921 8
E91414

1 3 5 7

R
2 4 6 8
N
Voltage rating (Ue) 2P 230 V
4P 400 V
Operating frequency 50 Hz

Auxiliary
Type Width in 9 mm
module
Contact OFsp Contact Voltage
1A 110 V DC 16940 1
E91415

22 14
12 6A 230 V AC (AC15)

21
11

Accessory
Type Number of pole
Screw shield (set of 10) for upstream or 2P 16938
downstream 4P 16939

Acti 9 | Catalogue 2014 B-13


Protection RCCB-ID 125 A residual current
Earth leakage protection
circuit breaker (AC, A, SI types)
(cont.)
Connection
b By tunnel terminals for:
Type Tightening Copper cables
DB123737

torque Rigid Flexible or ferrule


11 mm
6.5 mm

DB112804

DB112805
PZ2

RCCB-ID 3 N.m 1 x 1.5 to 50 mm2 1 x 1.5 to 35 mm2


2 x 1.5 to 16 mm2 2 x 1.5 to 16 mm2
OFsp 0.8 N.m 1 to 1.5 mm2 1 to 1.5 mm2

Technical data
OFsp contact status, depending on the Electrical characteristics
position of the residual current circuit Insulation voltage (Ui) 400 V
breaker Pollution degree 3
Type Rated impulse withstand voltage (Uimp) 4 kV
RCCB-ID Closed b - - According to IEC/EN 61008-1
125 A Making and breaking capacity (Im/IDm) 1250 A
Open - b -
Tripped on - - b Surge current AC and A types (no selective s) 250 Â
fault withstand (8/20 μs)
without tripping
SI type (no selective s) 3 kÂ
Contact 22/21 Open Closed Closed
OFsp 12/11 AC, A and SI types (selective s) 3 kÂ
14/11 Closed Open Open Conditional rated With FU 125 A gG fuse 10,000 A
short circuit current
(Inc/IDc)
DB122835

Additional characteristics
Degree of protection Device only IP20
IP40 with screw shield
Device in modular enclosure IP40
Insulation classe II
Endurance (O-C) Electrical > 2 000 cycles
Mechanical > 5 000 cycles
Operating temperature -25°C to +40°C
Storage temperature -40°C to +85°C
Indication of the status of the
RCCB-ID via the 3-position toggle
and front panel indicator
b Closed (red indicator)
b Tripped on fault (green indicator)
b Open (green indicator)
Weight (g)
Residual current circuit breakers and auxiliary
Type RCCB-ID 125 A OFsp
2P 230 40
4P 420

Dimensions (mm)
0140302_1

DB124103

2P 4P
RCCB-ID 125 A Contact OFsp

B-14 Acti 9 | Catalogue 2014


Protection RCCB-ID B type
Earth leakage protection

IEC/EN 61008, VDE 0664

b The RCCB-ID 125 A residual current circuit breakers provide:


PB101616_SE-35

PB107510-33 v protection of persons against electric shock by direct contact (30 mA),
v protection of persons against electric shock by indirect contact (u 300 mA),
v protection of installations against the risk of fire (300 mA or 500 mA).
B type
The RCCB-ID B type residual current circuit breakers provide:
b protection in the event of a continuous fault current on three-phase networks
generated by:
v controllers and variable speed drives,
v battery chargers and inverters,
16766 16940 v backed-up power supplies.

b They include and also guarantee protection against fault currents:


PB100572-18

v sinusoidal AC residual currents (AC type),


v pulsed DC residual currents (A type).

They can be adapted to all the application cases defined in standards IEC 60364 and
16939
EN 50178.
b Schneider Electric guarantees that the type B RCCB-ID works correctly in
combination with the variable speed drives manufactured by Schneider Electric.

OFsp auxiliary
b Electrical indication: by OFsp auxiliary mounted to the left.
It has a double changeover switch indicating the "open" or "closed" position of the
RCCB-ID B type .

Accessories
b 4P sealable screw shield.

Catalogue numbers
RCCB-ID B type residual current circuit breakers
Type B Width in 9 mm
module
B
4P Sensitivity 30 mA 300 mA 300 mA s 500 mA
Rating 25 A 16750 16751 - - 8
DB123726

40 A 16752 16753 16754 16755


63 A 16756 16757 16758 16759
80 A 16760 16761 16762 -
125 A 16763 16764 16765 16766

Voltage rating (Ue) 230/400 V


Operating frequency 50 Hz

Auxiliary
Type Width in 9 mm
module
Contact OFsp Contact Voltage
1A 110 V DC 16940 1
E91415

22 14
12 6A 230 V AC (AC15)

21
11

Accessory
Type Number of pole
Screw shield (set of 10) for upstream or downstream 4P 16939

Acti 9 | Catalogue 2014 B-15


Protection RCCB-ID B type (cont.)
Earth leakage protection

Connection
b By tunnel terminals for:
Type Tightening Copper cables
DB123736

torque Rigid Flexible or ferrule


11 mm
6,5 mm

DB112804

DB112805
PZ2

RCCB-ID B type 3 N.m 1 x 1.5 to 50 mm2 1 x 1.5 to 35 mm2


2 x 1.5 to 16 mm2 2 x 1.5 to 16 mm2
OFsp 0.8 N.m 1 to 1.5 mm2 1 to 1.5 mm2

Technical data
OFsp contact status, depending on the Electrical characteristics
position of the residual current circuit Insulation voltage (Ui) 400 V
breaker Pollution degree 3
Type Rated impulse withstand voltage (Uimp) 4 kV
RCCB-ID Closed b - - According to IEC/EN 61008-1
B type Making and breaking 25/40 A 500 A
Open - b -
capacity (Im/IDm) 63/80 A 800 A
Tripped on - - b
fault 125 A 1250 A
Contact 22/21 Open Closed Closed
Surge current withstand No selective s 250 Â
OFsp 12/11
(8/20 μs) without tripping Selective s 3 kÂ
14/11 Closed Open Open
Conditional rated short 25/40 A with FU 80 A gG fuse 10,000 A
circuit current (Inc/IDc)
63 A with FU 100 A gG fuse 10,000 A
80/125 A with FU 125 A gG fuse 10,000 A
DB122842

Additional characteristics
Degree of protection Device only IP20
IP40 with screw shield
Device in modular enclosure IP40
Insulation classe II
Endurance (O-C) Electrical > 2 000 cycles
Mechanical > 5 000 cycles
Operating temperature -25°C to +40°C
Storage temperature -40°C to +85°C
Indication of the status of the
RCCB-ID B type via the 3-position
toggle and front panel indicator
b Closed (red indicator)
b Tripped on fault (green indicator)
b Open (green indicator)

Weight (g)
Residual current circuit breakers and auxiliary
Type RCCB-ID B type OFsp
4P 450 40

Dimensions (mm)
DB122838

212410

2P 4P
RCCB-ID B type Contact OFsp

B-16 Acti 9 | Catalogue 2014


Protection Vigi iC60 add-on residual
Earth leakage protection
current devices (AC type)

IEC/EN 61009-1
DB116619

b Combined with iC60 circuit breaker, the Vigi iC60 provide:


PB104466-35

PB104471-35

v protection of persons against electric shock by direct contact (y 30 mA),


v protection of persons against electric shock by indirect contact (u 100 mA),
v protection of installations against the risk of fire (300 mA or 500 mA).

Catalogue numbers
Vigi iC60 add-on residual current devices
Type AC Width in 9 mm
modules
Product Vigi iC60
Auxiliaries Without auxiliaries
2P Sensitivity 10 mA 30 mA 100 mA 300 mA 500 mA 300 mA s 1000 mA s
Rating 25 A A9V10225 A9V41225 A9V12225 A9V44225 A9V16225 - - 3
DB122462

A9V01225* A9V04225*
40 A - A9V41240 - A9V44240 A9V16240 - - 4

B
A9V01240* A9V04240*
63 A - A9V41263 A9V12263 A9V44263 A9V16263 A9V15263 A9V19263 4
A9V01263* A9V04263*
3P Sensitivity 10 mA 30 mA 100 mA 300 mA 500 mA 300 mA s 1000 mA s
Rating 25 A - A9V41325 - A9V44325 A9V16325 - - 6
DB122463

40 A - A9V41340 - A9V44340 A9V16340 - - 7


63 A - A9V41363 - A9V44363 A9V16363 A9V15363 A9V19363 7

4P Sensitivity 10 mA 30 mA 100 mA 300 mA 500 mA 300 mA s 1000 mA s


Rating 25 A - A9V41425 A9V12425 A9V44425 A9V16425 - - 6
DB122464

40 A - A9V41440 - A9V44440 A9V16440 - - 7


63 A - A9V41463 A9V12463 A9V44463 A9V16463 A9V15463 A9V19463 7

Voltage rating (Ue) 230 - 240 V, 400 - 415 V


Except * 130 V
Operating frequency 50/60 Hz
Accessories See page E-2

Acti 9 | Catalogue 2014 B-17


Protection Vigi iC60 add-on residual
Earth leakage protection
current devices (A type)

IEC/EN 61009-1
DB116619

b Combined with iC60 circuit breaker, the Vigi iC60 provide:


PB104466-35

PB104471-35

v protection of persons against electric shock by direct contact (30 mA),


v protection of persons against electric shock by indirect contact (u 100 mA),
v protection of installations against the risk of fire (300 mA or 500 mA).

Catalogue numbers
Vigi iC60 add-on residual current devices
Type A Width in 9 mm
modules
Product Vigi iC60
Auxiliaries Without auxiliaries
2P Sensitivity 30 mA 100 mA 300 mA 500 mA 300 mA s 1000 mA s
Rating 25 A A9V51225 A9V22225 A9V54225 A9V26225 - - 3
DB122462

63 A A9V51263 A9V22263 A9V54263 A9V26263 A9V25263 A9V29263 4

3P Sensitivity 30 mA 100 mA 300 mA 500 mA 300 mA s 1000 mA s


Rating 25 A A9V51325 A9V22325 A9V54325 A9V26325 - - 6
DB122463

63 A A9V51363 - A9V54363 A9V26363 A9V25363 A9V29363 7

4P Sensitivity 30 mA 100 mA 300 mA 500 mA 300 mA s 1000 mA s


Rating 25 A A9V51425 A9V22425 A9V54425 A9V26425 - - 6
DB122464

63 A A9V51463 A9V22463 A9V54463 A9V26463 A9V25463 A9V29463 7

Voltage rating (Ue) 230 - 240 V, 400 - 415 V


Operating frequency 50/60 Hz
Accessories See page E-2

B-18 Acti 9 | Catalogue 2014


Protection Vigi iC60 add-on residual
Earth leakage protection
current devices (SI type)

IEC/EN 61009-1
DB116619

b Combined with iC60 circuit breaker, the Vigi iC60 provide:


PB104466-35

PB104471-35

v protection of persons against electric shock by direct contact (y 30 mA),


v protection of persons against electric shock by indirect contact (u 300 mA),
v protection of installations against the risk of fire (300 mA).

The SI type provides increased immunity from electrical interference and polluted or
corrosive environments.

Catalogue numbers
Vigi iC60 add-on residual current devices
Type SI Width in 9 mm
modules
Product Vigi iC60
Auxiliaries Without auxiliaries
2P Sensitivity 10 mA 30 mA 300 mA s 1000 mA s
Rating 25 A A9V30225 A9V61225 - - 3
DB122462

40 A - A9V61240 - - 4
63 A - A9V61263 A9V65263 A9V39263 4

B
3P Sensitivity 10 mA 30 mA 300 mA s 1000 mA s
Rating 25 A - A9V61325 - - 6
DB122463

40 A - A9V61340 - - 7
63 A - A9V61363 A9V65363 A9V39363 7

4P Sensitivity 10 mA 30 mA 300 mA s 1000 mA s


Rating 25 A - A9V61425 - - 6
DB122464

40 A - A9V61440 - - 7
63 A - A9V61463 A9V65463 A9V39463 7

Voltage rating (Ue) 230 - 240 V, 400 - 415 V


Operating frequency 50/60 Hz
Accessories See page E-2

Acti 9 | Catalogue 2014 B-19


Protection Vigi iC60 add-on residual
Earth leakage protection
current devices (AC, A, SI types)

Connection
Type Rating Tightening torque Copper cables
DB122948

Rigid Flexible or ferrule

DB122945

DB122946
6.5 mm
PZ2
Vigi iC60 25 A 2 N.m 1 to 25 mm2 1 to 16 mm2
40 to 63 A 3.5 N.m 1 to 35 mm2 1 to 25 mm2
14 mm
DB123310

Technical data
Main characteristics
Insulation voltage (Ui) 500 V
Pollution degree 3
Rated impulse withstand voltage (Uimp) 6 kV
Clip on DIN rail 35 mm. According to IEC/EN 61009-1
Surge current AC and A types (no selective s) 250 Â
DB123312

withstand (8/20 μs) AC, A types (selective s) 3 kÂ


without tripping
SI type 3 kÂ
Additional characteristics
Degree of protection Device only IP20
Device in modular enclosure IP40
Insulation classe II
Operating AC type -5°C to +60°C
Indifferent position of installation.
temperature
A and SI types -25°C to +60°C
Storage temperature -40°C to +85°C
IP20 IP40
DB123314

Weight (g)
Add-on residual current devices
Type Vigi iC60
2P 165
3P 210
4P 245
Dimensions (mm)
Vigi iC60 25 A
DB122766

73.5

36 27 54 54 72 54 5.5 44 20

91 91 91 101 91 45

2P 3P 4P

Vigi iC60 40 and 63 A 73.5

36 36 54 63 72 63 5.5 44 20

91 91 91 101 91 45

2P 3P 4P

B-20 Acti 9 | Catalogue 2014


Protection Vigi iC60 add-on residual
Earth leakage protection
current devices (AC, A, SI types)
(cont.)
Association iC60a, N, H, L + Vigi iC60
PB104556-51

iC60 Vigi iC60 Vigi iC60 Vigi iC60


25 A 40 A 63 A
005 A to 25 A b b b
32 A 0 40 A NO b b
50 A 0 63 A NO NO b

Association iC60L-MA + Vigi iC60


iC60 Vigi iC60 Vigi iC60 Vigi iC60
25 A 40 A 63 A
106 A to 16 A b b b
25 A NO b b
40 A NO NO b

d Combining iC60 L-MA units with Vigi modules of higher rating.


PB104466-40

Visi-trip window
b Fault tripping is indicated by a red
mechanical indicator on the front face.

b Test button

B
b Insulated terminals IP20

b Large circuit labelling area

b Screw-shield enabling
connection checking and
retightening

b Double clip for


dismounting with comb
busbar in place

SI type
The SI type provides increased immunity from electrical interference and polluted or
corrosive environments.

Acti 9 | Catalogue 2014 B-21


Protection Vigi C120 add-on residual
Earth leakage protection
current devices
(types AC, A and SI) (cont.)
b Polarizing slot

b Fault indication by the red


strip on the reset toggle

b Test button

b Terminals insulated
to IP20

b Screw shield allowing the


connections to be checked and
retightened

Type SI
The SI type provides increased immunity from electrical interference and polluted or
corrosive environments.

B-22 Acti 9 | Catalogue 2014


Protection Vigi C120 add-on residual
Earth leakage protection
current devices (type AC)

EN 61009
PB107924-30

When a Vigi C120 device is combined with a C120 circuit breaker, it provides the
following functions:
b protection of persons against electric shock by direct contact (30 mA),
b protection of persons against electric shock by indirect contact (u 300 mA),
2P
b protection of installations against fire hazards (300 mA to 1000 mA).
PB107925-30

3P
PB107926-30

4P

Catalogue numbers B
Vigi C120 add-on residual current devices
Type AC Width in 9 mm
Product Vigi C120 modules
Auxiliaries Without auxiliary
2P Sensitivity 30 mA 300 mA 500 mA 300 mA s 1000 mA s
A9N18563 A9N18564 A9N18565 A9N18544 A9N18545 7
dess. 077

1 3
T

2 4

3P Sensitivity 30 mA 300 mA 500 mA 300 mA s 1000 mA s


A9N18566 A9N18567 A9N18568 A9N18546 A9N18547 10
dess. 079

1 3 5
T

2 4 6

4P Sensitivity 30 mA 300 mA 500 mA 300 mA s 1000 mA s


A9N18569 A9N18570 A9N18571 A9N18548 A9N18549 10
dess. 078B

1 3 5 7
T
A9N18542(1) A9N18543(1)

2 4 6 8

Operating voltage (Ue) 230...415 V


Operating frequency 50/60 Hz
Accessories See page E-7 and E-15

(1) specific offer for France

Acti 9 | Catalogue 2014 B-23


Protection Vigi C120 add-on residual
Earth leakage protection
current devices (type A)

EN 61009
When a Vigi C120 device is combined with a C120 circuit breaker, it provides the
following functions:
PB107924-30

b protection of persons against electric shock by direct contact (30 mA),


b protection of persons against electric shock by indirect contact (u 300 mA),
b protection of installations against fire hazards (300 mA to 1000 mA).

2P
PB107925-30

3P
PB107926-30

4P

Catalogue numbers
Vigi C120 add-on residual current devices
Type A Width in 9 mm
Product Vigi C120 modules
Auxiliaries Without auxiliary
2P Sensitivity 30 mA 300 mA 500 mA 300 mA s 500 mA s 1000 mA s
A9N18572 A9N18573 A9N18574 A9N18581 A9N18582 A9N18583 7
dess. 077

1 3
T

2 4

3P Sensitivity 30 mA 300 mA 500 mA 300 mA s 500 mA s 1000 mA s


A9N18575 A9N18576 A9N18577 A9N18584 A9N18585 A9N18586 10
dess. 079

1 3 5
T

2 4 6

4P Sensitivity 30 mA 300 mA 500 mA 300 mA s 500 mA s 1000 mA s


A9N18578 A9N18579 A9N18580 A9N18587 A9N18588 A9N18589 10
dess. 078B

1 3 5 7
T

2 4 6 8

Operating voltage (Ue) 230...415 V


Operating frequency 50/60 Hz
Accessories See page E-15 and E-7

B-24 Acti 9 | Catalogue 2014


Protection Vigi C120 add-on residual
Earth leakage protection
current devices (type SI)

EN 61009

When a Vigi C120 device is combined with a C120 circuit breaker, it provides the
PB107924-30

following functions:
b protection of persons against electric shock by direct contact (30 mA),
b protection of persons against electric shock by indirect contact (u 300 mA),
b protection of installations against fire hazards (300 mA to 1000 mA).

Special feature of type SI :


They are appropriate for operating in environments with:
b high risk of nuisance tripping: frequent lightning strikes, IT system, presence of
electronic ballasts, frequency converters, presence of switchgear incorporating
2P
lighting type interference filters, computer system, etc.
b blind sources:
PB107925-30

v presence of harmonics or high frequency rejections


v presence of DC components: diodes, diode bridges, switch-mode power supplies,
etc.
b protected against nuisance tripping caused by transient voltage surges (lightning
strike, operation of switchgear on the network, etc.)

3P
PB107926-30

4P

Catalogue numbers
B
Vigi C120 add-on residual current devices
Type SI Width in 9 mm
Product Vigi C120 modules
Auxiliaries Without auxiliary
2P Sensitivity 30 mA 300 mA 500 mA 300 mA s 1000 mA s
A9N18591 A9N18592 A9N18593 A9N18556 A9N18557 7
dess. 077

1 3
T

2 4

3P Sensitivity 30 mA 300 mA 500 mA 300 mA s 1000 mA s


A9N18594 A9N18595 A9N18596 A9N18558 A9N18559 10
dess. 079

1 3 5
T

2 4 6

4P Sensitivity 30 mA 300 mA 500 mA 300 mA s 1000 mA s


A9N18597 A9N18598 A9N18599 A9N18560 A9N18561 10
dess. 078B

1 3 5 7
T
A9N18554(1) A9N18555(1)

2 4 6 8

Operating voltage (Ue) 230...415 V


Operating frequency 50 Hz
Accessories See page E-7 and E-15

(1) specific offer for France

Acti 9 | Catalogue 2014 B-25


Protection Vigi C120 add-on residual
Earth leakage protection
current devices
(types AC, A and SI)
Connection
Type Sensitivity Tightening Copper cables
DB123774

torque Rigid Flexible or with ferrule

DB122945

DB122946
6.5 mm

PZ2 Vigi C120 30...1000 mA 3.5 N.m 1 to 50 mm2 1 to 35 mm2

15 mm

Technical data
DB123310

Main characteristics
To IEC 60947-2
Insulation voltage (Ui) 500 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 6 kV
Clips onto 35 mm DIN rail.
To EN 61009
Impulse current Types AC and A (non-selective s) 250 Â
withstand (8/20 μs) Types AC and A (selective s) 3 kÂ
DB123312

without tripping
Types SI (non-selective s) 3 kÂ
Types SI (selective s) 5 kÂ
Additional characteristics
Degree of protection Device only IP20
Device in a modular enclosure IP40
Insulation class II
Any installation position. Operating temperature Type AC -5 °C to +60 °C
Types A and SI -25 °C to +60 °C
Storage temperature -40 °C to +85 °C
IP20 IP40
DB123314

Weight (g)
Add-on residual current devices
Type Vigi C120
2P 325
3P 500
4P 580

Dimensions (mm)
C120 + Vigi C120
148-0503

B-26 Acti 9 | Catalogue 2014


Protection Vigi NG125 add-on residual
Earth leakage protection
current devices (AC, A, SI types)

Association NG125 + Vigi NG125


056341_SE-50

Vigi NG125 Vigi NG125


63 A 125 A
NG125 y 63 A b NO
NG125 80…125 A* NO b
(*) No Vigi add-on residual current device for 2P circuit breakers of rating 80 A.

b Test button
Vigi 125 A and adjustable
b MXV remote tripping auxiliary
Vigi 125 A and adjustable
b Auxiliary for electrical indication of tripping
upon earth fault: SDV
PB104466-40

b Earth fault indicator light

b Mechanical indication of
earth fault
B
Vigi 125 A adjustable
b Disconnection (essential)
for dielectric test by integral
pushbutton

3P, 4P
b Device for unlocking on
b Rigid connections isolated by DIN rail on front face
supplied wire cover
b Insulated terminals IP20

b Alert threshold setting


b Setting of tripping threshold IΔn
b Setting of time delay

SI type
SI types are appropriate for operating in environments with:
b High risk of nuisance tripping: frequent lightning strikes, IT system, presence of
electronic ballasts, frequency converters, presence of switchgear incorporating
lighting type interference filters, computer system, etc.
b Blind sources
v presence of harmonics or high frequency rejections,
v presence of DC components: diodes, diode bridges, switch-mode power supplies,
etc.
b Protected against nuisance tripping caused by transient voltage surges (lightning
strike, operation of switchgear on the network, etc.).

Acti 9 | Catalogue 2014 B-27


Protection Vigi NG125 add-on residual
Earth leakage protection
current devices (AC type)

IEC/EN 60947-2
DB116619
PB103984-40

PB103985-40

PB103986-40

b When it is combined with an NG125 circuit breaker, the Vigi NG125 add-on
residual current device offers the following functions:
v protection of persons against electric shocks by direct contact (30 mA),
v protection of persons against electric shocks by indirect contact (300 mA),
v protection of installations against fire risks (300 mA).

Catalogue numbers
Vigi NG125 add-on residual current devices
Type AC Width in 9 mm
modules
Product Vigi NG125
Auxiliaries Without auxiliaries
2P Sensitivity 30 mA 300 mA
Rating 63 A 19000 19001 5
DB122462

3P Sensitivity 30 mA 300 mA
Rating 63 A 19002 19003 9
DB122463

4P Sensitivity 30 mA 300 mA
Rating 63 A 19004 19005 9
DB122464

Voltage rating (Ue) 230 - 240 V, 400 - 415 V


Operating frequency 50/60 Hz
Accessories See page E-26

B-28 Acti 9 | Catalogue 2014


Protection Vigi NG125 add-on residual
Earth leakage protection
current devices (A type)

IEC/EN 60947-2
DB116619
054383M-40

PB103998-40

b When it is combined with an NG125 circuit breaker, the Vigi NG125 add-on
residual current device offers the following functions:
v protection of persons against electric shocks by direct contact (30 mA),
v protection of persons against electric shocks by indirect contact (u 300 mA),
v protection of installations against fire risks (300 mA or 500 mA).

Catalogue numbers

B
Vigi NG125 add-on residual current devices
Type A Width in 9 mm
modules
Product Vigi NG125
Auxiliaries See page F-14
2P Sensitivity 30 mA 300 mA 300 mA s 1000 mA s 300…1000 I/S 300…3000 I/S/R
Rating 63 A 19010 19012 19030 19031 - - 5
DB122462

19008 (1) 19009 (1)

3P Sensitivity 30 mA 300 mA 300 mA s 1000 mA s 300…1000 I/S 300…3000 I/S/R


Rating 63 A 19013 19014 19032 19033 - - 9
DB122463

- - - - - 19036 11
19053 (2)
125 A 19039 - - - 19044 19047 11
19055 (2)

4P Sensitivity 30 mA 300 mA 300 mA s 1000 mA s 300…1000 I/S 300…3000 I/S/R


Rating 63 A 19015 19016 19034 19035 - - 9
DB122464

- - - - - 19037 11
19054 (2)
125 A 19041 19042 - - 19046 19049 11
19056 (2)

Voltage rating (Ue) 230 - 240 V, 400 - 415 V


Except: (1) 110…220 V and (2) 440…500 V
Operating frequency 50/60 Hz
Accessories See page E-26

Acti 9 | Catalogue 2014 B-29


Protection Vigi NG125 add-on residual
Earth leakage protection
current devices (SI type)

IEC/EN 60947-2
DB116619
057484-40

b When it is combined with an NG125 circuit breaker, the Vigi NG125 add-on
residual current device offers the following functions:
v protection of persons against electric shocks by direct contact (30 mA),
v protection of persons against electric shocks by indirect contact (u 300 mA),
v protection of installations against fire risks (300 mA or 500 mA).

SI types are appropriate for operating in environments with:


b High risk of nuisance tripping: frequent lightning strikes, IT system, presence of
electronic ballasts, frequency converters, presence of switchgear incorporating
lighting type interference filters, computer system, etc.
b Blind sources
v presence of harmonics or high frequency rejections,
v presence of DC components: diodes, diode bridges, switch-mode power supplies,
etc.
b Protected against nuisance tripping caused by transient voltage surges (lightning
strike, operation of switchgear on the network, etc.).

Catalogue numbers
Vigi NG125 add-on residual current devices
Type SI Width in 9 mm
modules
Product Vigi NG125
Auxiliaries See page F-14
3P Sensitivity 30 mA 300…3000 I/S/R
Rating 125 A 19100 19106 11
DB122463

4P Sensitivity 30 mA 300…3000 I/S/R


Rating 125 A 19101 19107 11
DB122464

Voltage rating (Ue) 230 - 240 V, 400 - 415 V


Operating frequency 50/60 Hz
Accessories See page E-26

B-30 Acti 9 | Catalogue 2014


Protection Vigi NG125 add-on residual
Earth leakage protection
current devices (AC, A, SI types)

Connection Without accessories With accessories


Rating Tightening Copper cables 70 mm2 Al Screw-on
DB123404

torque Rigid Flexible or Screw terminal connection for


ferrule clamp ring terminal
6.5 mm terminal
PZ2

DB122945

DB122946

DB123409

DB123410

DB123488
20 mm

63 A 3.5 N.m 1.5 to 50 mm2 1 to 35 mm2 - - -


125 A 6 N.m 16 to 70 mm2 10 to 50 mm2 - 25 to 70 mm2 2 x 35 mm2
DB123405

1 x 50 mm2

20 mm

Pre-alarm 1 N.m 2 x 2.5 mm2 2 x 1.5 mm2 2 x 1.5 mm2 - -


DB123408

5 mm
PZ1

Technical data
DB123310

Main characteristics
Insulation voltage (Ui) 690 V
Pollution degree
Rated impulse withstand voltage (Uimp)
3
8 kV B
According to IEC/EN 61009-1
Clip on DIN rail 35 mm. Surge current Selective s or R 5 kÂ
withstand (8/20 μs) Instantaneous 3 kÂ
without tripping
DB123312

Additional characteristics
Degree of protection Device only IP20
Device in modular enclosure IP40
Operating AC type -5°C to +60°C
temperature
A and SI types -25°C to +60°C
Storage temperature -40°C to +85°C
Indifferent position of installation. Additional characteristics
Vigi 125 A and adjustable
Plug-in auxiliaries MXV Remote tripping
IP20 IP40
DB123314

SDV Indication of tripping upon


earth fault
Adjustable Vigi
Sensitivity adjustable by notch (IΔn) 300, 500, 1000, 3000 mA
Tripping time Instantaneous
Selective s 60 ms
Time-delayed 150 ms
Leakage current indication on 3P and 4P On front face by LED
300...3000 I/S/R (pre-alarm) Remote, by potential-free normally-open
contact 250 V - 1 A (low level)
Threshold setting by potentiometer from
10 % to 50 % of IΔn
Disconnection essential for dielectric test By integral pushbutton

Acti 9 | Catalogue 2014 B-31


Protection Vigi NG125 add-on residual
Earth leakage protection
current devices (AC, A, SI types)
(cont.)
Weight (g)
Add-on residual current devices
Number of 9 mm modules 2P 3P 4P
5 modules 250 - -
9 modules - 410 450
11 modules - 750 800

Dimensions (mm)
DB123406

NG125 NG125 NG125


2P 3P/4P 3P/4P

2P (5 modules) 63, 125 A (9 modules) 63, 125 A (11 modules)

54.25 26.75 72.25 26.75


DB123587

NG125 16.25 NG125 16.25


3P/4P 3P/4P

101.75 101.75

Spacing for mounting on panel

B-32 Acti 9 | Catalogue 2014


Protection Vigi modules and residual
Earth leakage protection
current devices i DPN

Earth leakage protection for “Group Feeders” is IEC/EN 61009-1 and 61009-2-1
performed:
b either by a monobloc residual current device
b or by a circuit breaker combined with a Vigi module.
PB107115-32

Catalogue numbers
i DPN Vigi residual current devices 4500 EN 61009 - C curve
Type AC Width in 9-mm
modules
Auxiliairies See page E-31
3P+N Sensitivity 30 mA 300 mA 300 mA s
N Rating 25 A A9N21771 A9N21775 A9N21772 12
DB123673

N
40 A A9N21773 A9N21776 A9N21774
T
PB107113-32

PB107155-32

Catalogue numbers
"Group Feeder" i DPN Vigi modules
Type AC A SI Width in
9-mm
modules
Auxiliairies Without auxiliairy Without auxiliairy Without auxiliairy
1P+N Sensitivity 30 mA 300 mA 300 mA s 30 mA 300 mA 30 mA 300 mA 300 mA s
N N Rating 25 A A9N21741 A9N21742 - A9N21745 A9N21746 A9N21749 A9N21750 - 2
DB123669

T 40 A A9N21743 A9N21744 - A9N21747 A9N21748 A9N21751 A9N21752 A9N21753

N N

3P+N Sensitivity 30 mA 300 mA 300 mA s 30 mA 300 mA 30 mA 300 mA 300 mA s


N N Rating 25 A A9N21755 A9N21756 - A9N21759 A9N21760 A9N21763 A9N21764 - 6
DB123671

T 40 A A9N21757 A9N21758 - A9N21761 A9N21762 A9N21765 A9N21766 A9N21767


63 A A9N26846 A9N26847 A9N26848 - - A9N26849 - -

N N

Acti 9 | Catalogue 2014 B-33


Protection Vigi modules and residual
Earth leakage protection
current devices i DPN (cont.)

IEC/EN 61009-1 and 61009-2-1

For the earth leakage protection of "outgoers", a Catalogue numbers


residual current device is built by combining a
i DPN Vigi residual current devices 4500 EN 61009 - C curve
circuit breaker and a Vigi module.
"Outgoer" residual current devices are also Type AC Width in 9-mm
modules
available in monobloc version.
Auxiliairies Add-on auxiliaries: see
modules F-9 and
PB107169-32

E-31
1P+N Sensitivity 30 mA 300 mA
Rating 6 A A9N21614 A9N21624 4
10 A A9N21615 A9N21625
DB123672
N

T 16 A A9N21616 A9N21626
20 A A9N21617 A9N21627
25 A A9N21618 A9N21628
N 32 A A9N21619 A9N21629
40 A A9N21620 A9N21630
PB107111-32

PB107112-32

PB107114-32

Catalogue numbers
"Outgoer" i DPN Vigi modules
Type AC A SI Width in 9-mm
modules
1P+N Sensitivity 30 mA 100 mA 300 mA 30 mA 300 mA 30 mA 300 mA
N N Rating 25 A A9N21681 A9N21678 A9N21682 A9N21685 A9N21686 A9N21689 A9N21690 2
DB123669

T A9N21680 A9N21679
Type G Type G
40 A A9N21683 - A9N21684 A9N21687 A9N21688 A9N21691 A9N21692

N N

3P Sensitivity 30 mA 100 mA 300 mA 30 mA 300 mA 30 mA 300 mA


Rating 25 A A9N21695 - A9N26696 A9N21699 A9N21700 A9N21703 A9N21704 4
DB123670

T
40 A A9N21697 - A9N26698 A9N21701 A9N21702 A9N21705 A9N21706

3P+N Sensitivity 30 mA 100 mA 300 mA 30 mA 300 mA 30 mA 300 mA


N N Rating 25 A A9N21709 - A9N21710 A9N21713 A9N21714 A9N21717 A9N21718 4
DB123671

T 40 A A9N21711 - A9N21712 A9N21715 A9N21716 A9N21719 A9N21720

N N

B-34 Acti 9 | Catalogue 2014


Protection Residual current devices
Earth leakage protection
iDPN Vigi

IEC/EN 61009
DB116619

b The iDPN Vigi residual current device provide complete protection for final circuits
PB110000-40

PB110001-40

(against overcurrents and insulation faults):


v protection for users against electric shocks by direct contacts (y 30 mA),
v protection for users against electric shocks by indirect contacts (300 mA),
v protection of the installations against fire risks (300 mA).

b The SI range has been designed to maintain a network with optimum safety and
continuity of service in installations disturbed by:
v extreme atmospheric conditions,
v harmonic generating loads,
v transient operating currents.

iDPNa Vigi iDPN H Vigi

Catalogue numbers
iDPNa Vigi 4500
Type AC A Width in 9 mm
modules
Auxiliaries Remote tripping and indication, see pages E-2 and F-2
1P+N Curve B Sensitivity 30 mA 300 mA 10 mA 30 mA
N 1 Rating 6A A9D51606 - - A9D54606 4
DB123871

(In) 10 A A9D51610 - - A9D54610


13 A - - - A9D54613
16 A A9D51616 - - A9D54616
20 A A9D51620 - - A9D54620
R
25 A A9D51625 - - A9D54625
32 A A9D51632 - - A9D54632
N 2
40 A A9D51640 - - A9D54640
1P+N Curve C
N 1 Rating
Sensitivity 30 mA
6A A9D34606
300 mA
A9D44606
10 mA
-
30 mA
A9D35606 4
B
DB123871

(In) 10 A A9D34610 A9D44610 A9D05610 A9D35610


13 A - - - A9D35613
16 A A9D34616 A9D44616 A9D05616 A9D35616
20 A A9D34620 A9D44620 - A9D35620
R
25 A A9D34625 A9D44625 - A9D35625
32 A A9D34632 A9D44632 - A9D35632
N 2
40 A A9D34640 A9D44640 - A9D35640
Voltage rating (Ue) 230 V AC
Operating frequency 50 Hz
Accessories See pages E-6 , E-10 and E-29

iDPN N Vigi G Type 6000


PB110002-40

Type AC A Width in 9 mm
modules
Auxiliaries Remote tripping and indication,
see pages E-2 and F-2
1P+N Curve C Sensitivity 30 mA 100 mA
N 1 Rating 6 A A9D62606 A9D72606 4
DB123871

(In) 10 A A9D62610 A9D72610


13 A A9D62613 A9D72613
16 A A9D62616 A9D72616

iDPN N Vigi
N 2

Voltage rating (Ue) 230 V AC


Operating frequency 50 Hz
Accessories See pages E-6 , E-10 and E-29

Acti 9 | Catalogue 2014 B-35


Protection Residual current devices
Earth leakage protection
iDPN Vigi (cont.)

iDPN N Vigi 6000


Type AC A SI Width in 9 mm
modules
Auxiliaries Remote tripping and indication, see pages E-2 and F-2
1P+N Curve B Sensitivity 30 mA 300 mA 10 mA 30 mA 100 mA 300 mA 30 mA 100 mA 300 mA
N 1 Rating 4 A A9D55604 A9D68604 - A9D56604 A9D60604 A9D69604 - - - 4
DB123871

(In) 6A A9D55606 A9D68606 - A9D56606 A9D60606 A9D69606 - - -


10 A A9D55610 A9D68610 A9D08610 A9D56610 A9D60610 A9D69610 - - -
13 A - - - A9D56613 A9D60613 A9D69613 - - -
16 A A9D55616 A9D68616 A9D08616 A9D56616 A9D60616 A9D69616 - - -
R 20 A A9D55620 A9D68620 - A9D56620 A9D60620 A9D69620 - - -
25 A A9D55625 A9D68625 - A9D56625 A9D60625 A9D69625 - - -
32 A A9D55632 A9D68632 - A9D56632 A9D60632 A9D69632 - - -
N 2
40 A A9D55640 A9D68640 - A9D56640 A9D60640 A9D69640 - - -
1P+N Curve C Sensitivity 30 mA 300 mA 10 mA 30 mA 100 mA 300 mA 30 mA 100 mA 300 mA
Rating 6 A A9D31606 A9D41606 - A9D32606 A9D52606 A9D42606 A9D33606 A9D53606 A9D43606 4
DB123871

N 1
(In) 10 A A9D31610 A9D41610 A9D02610 A9D32610 A9D52610 A9D42610 A9D33610 A9D53610 A9D43610
13 A - - - A9D32613 A9D52613 A9D42613 A9D33613 A9D53613 A9D43613
16 A A9D31616 A9D41616 A9D02616 A9D32616 A9D52616 A9D42616 A9D33616 A9D53616 A9D43616
20 A A9D31620 A9D41620 - A9D32620 A9D52620 A9D42620 A9D33620 A9D53620 A9D43620
R 25 A A9D31625 A9D41625 - A9D32625 A9D52625 A9D42625 A9D33625 A9D53625 A9D43625
32 A A9D31632 A9D41632 - A9D32632 A9D52632 A9D42632 A9D33632 A9D53632 A9D43632
N 2 40 A A9D31640 A9D41640 - A9D32640 A9D52640 A9D42640 A9D33640 A9D53640 A9D43640
Voltage rating (Ue) 230 V AC
Operating frequency 50 Hz
Accessories See pages E-6 , E-10 and E-29

iDPN H Vigi 10000


Type A SI Width in 9 mm
modules
Auxiliaries Remote tripping and indication, see pages E-2 and F-2
1P+N Curve B Sensitivity 30 mA 300 mA 30 mA 300 mA
N 1 Rating 6A A9D07606 - - - 4
DB123871

(In) 10 A A9D07610 - - -
16 A A9D07616 - - -
20 A A9D07620 - - -
25 A A9D07625 - - -
R 32 A A9D07632 - - -

N 2

1P+N Curve C Sensitivity 30 mA 300 mA 30 mA 300 mA


Rating 6A A9D37606 A9D47606 A9D38606 A9D48606 4
DB123871

N 1
(In) 10 A A9D37610 A9D47610 A9D38610 A9D48610
16 A A9D37616 A9D47616 A9D38616 A9D48616
20 A A9D37620 A9D47620 A9D38620 A9D48620
25 A A9D37625 A9D47625 A9D38625 A9D48625
R
32 A A9D37632 A9D47632 A9D38632 A9D48632

N 2

Voltage rating (Ue) 230 V AC


Operating frequency 50 Hz
Accessories See pages E-6 , E-10 and E-29

B-36 Acti 9 | Catalogue 2014


Protection Residual current devices
Earth leakage protection
iDPN Vigi (cont.)

b Fast contact closure b Insulated terminals IP20

PB110002-40
Visi-trip double window b Test button
b Fault tripping circuit breaker is indicated by
a red mechanical indicator on the front face.
b Earth fault is indicated by a red mechanical Positive contact indication
indicator on the front face b A green strip on the toggle guarantees opening of
all the poles in safety conditions (padlocking
possible) for work to be carried out on live parts
DB123310

Connection
Rating Tightening Copper cables
DB123947

torque Rigid Flexible


15 mm or ferrule
Clip on DIN rail 35 mm. 5.5 mm

DB122945

DB122946
DB123312

PZ2 4 to 40 A 3.5 N.m 1 to 16 mm2 1 to 10 mm2

Technical data
Indifferent position of installation.
Main characteristics

IP20 IP40
Type
Insulation voltage (Ui)
iDPNa Vigi
400 V AC
iDPN N Vigi iDPN H Vigi
B
DB123314

Pollution degree 3
Rated impulse withstand voltage (Uimp) 4 kV
Setting temperature for ratings 30°C
Magnetic tripping Curve B Between 3 and 5 In
Curve C Between 5 and 10 In
According to EN 61009
Limitation class 3
Rated breaking capacity (Icn) 4500 A 6000 A 10,000 A
Rated residual breaking and making capacity 4500 A 6000 A 10,000 A
(IDm)

Weight (g) 8/20 µs impulse withstand Type AC 250 Â 250 Â 250 Â


Type A 250 Â 250 Â 250 Â
Residual current device Type SI - 3 k 3 kÂ
Type iDPN Vigi Additional characteristics
1P+N 125 Earth leakage protection with instantaneous 10, 30, 300 mA 10, 30, 100, 30, 300 mA
tripping 300 mA
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
enclosure Insulation classe II

Dimensions (mm) Endurance (O-C) Electrical y 20 A 20,000 cycles


u 25 A 10,000 cycles
36 5.5 44 20
Mechanical 20,000 cycles
DB124454

Overvoltage category (IEC 60364) III


5
Operating temperature Type AC -5°C to +60°C
85 45 Type A, SI -25°C to +60°C
Storage temperature -40°C to +85°C
5 Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95 % to 55°C)
73

Acti 9 | Catalogue 2014 B-37


Protect iC60 RCBO
Circuit protection 10, 30 and 100 mA

b Insulated terminals IP20 b Test push-button

DB405553
PB110075-70
Visi-trip window
b Fault tripping is indicated by a red
mechanical indicator on the front face
Positive contact indication
b The presence of the green strip guarantees
physical opening of the contacts and allows
operations to be performed on the downstream
circuit in complete safety
DB405556

DB405582

b Insulated terminals IP20

b Clip for dismounting


b Increased product service life thanks to fast closing independent of the speed of
actuation of the toggle.
b Remote indication, open/closed/tripped, by optional auxiliary contacts.

Connection
Type Rating Tightening torque Copper cables
DB405564

Rigid Flexible
14 mm 6.5 mm
DB122945

DB122946

PZ2
N in and L in 6 to 45 A 3.5 N.m 1 to 25 mm2 1 to 16 mm2
L out and N out 2 N.m 1 to 16 mm2 1 to 10 mm2
5.5 mm

PZ2

13 mm

B-38 Acti 9 | Catalogue 2014


Protect iC60N RCBO
Circuit protection 30 mA

IEC 61009-1,
IEC 61009-2-2

b The single-phase iC60N RCBO’s self-contained residual current device carries


PB110083-70

out complete protection of final circuits:


v protection against short-circuits and cable overloads,
v protection against electrocution by direct contact.
b The neutral is not interrupted when the device is tripped. Hence iC60N RCBO can
be used on most circuits, except for the ones operating under TT or IT earthing
systems.

Alternating current (AC) 50/60 Hz


Breaking capacity (Icn) according to IEC 61009-1
Voltage (Ue)
Ph/N 240 V
Rating (In) 6 to 45 A 6000 A

Accessory
Padlocking device
b Used to lock the toggle in the "open" or "closed" position by 4 mm diameter
padlock (not supplied).

Catalogue numbers
iC60N RCBO 6000
1P+N A Width in 9-mm

B
modules
C curve Voltage rating (V) Sensitivity (IΔn) 30 mA
240 Rating 6A A9D64806 2
DB405038

(In) 10 A A9D64810
16 A A9D64816
20 A A9D64820
25 A A9D64825
32 A A9D64832
40 A A9D64840
45 A A9D64845
Operating frequency 50…60 Hz
Auxiliaries See pages E-2 and F-2

Accessory
Type
Padlocking device (bag of 10 pieces) A9A27049

Acti 9 | Catalogue 2014 B-39


Protect iC60H RCBO
Circuit protection 30 and 100 mA

IEC 61009-1,
IEC 61009-2-2

b The single-phase iC60H RCBO’s self-contained residual current device carries


PB110075-70

out complete protection of final circuits:


v protection against short-circuits and cable overloads
v protection of persons against electric shock by direct contact
(30 mA sensitivities),
v protection of persons against electric shock by indirect contact
(100 mA sensitivity),
v protection of equipment against fires set by leakage currents
(100 mA sensitivity).
b The neutral is not interrupted when the device is tripped. Hence iC60H RCBO can
be used on most circuits, except for the ones operating under TT or IT earthing
systems.

Alternating current (AC) 50/60 Hz


Breaking capacity (Icn) according to IEC 61009-1
Voltage (Ue)
Ph/N 110 V 240 V
Rating (In) 6 to 45 A 10000 A 10000 A

Accessory
Padlocking device
b Used to lock the toggle in the "open" or "closed" position by 4 mm diameter
padlock (not supplied).

Catalogue numbers
iC60H RCBO 10000
1P+N A Width in 9-mm
modules
B curve Voltage rating (V) Sensitivity (IΔn) 10 mA* 30 mA 100 mA
240 Rating 6A A9D10806 A9D34806 - 2
DB405038

(In) 10 A A9D10810 A9D34810 -


16 A A9D10816 A9D34816 -
20 A A9D10820 A9D34820 -
25 A A9D10832 A9D34825 -
32 A A9D34832 -
40 A A9D34840 -
45 A A9D34845 -
C curve Voltage rating (V) Sensitivity (IΔn)
240 Rating 6A A9D10806 A9D14806 A9D15806 2
DB405038

(In) 10 A A9D10810 A9D14810 A9D15810


16 A A9D10816 A9D14816 A9D15816
20 A A9D10820 A9D14820 A9D15820
25 A A9D10832 A9D14825 A9D15825
32 A A9D14832 A9D15832
40 A A9D14840 A9D15840
45 A A9D14845 A9D15845
Operating frequency 50…60 Hz
Auxiliaries See pages E-2 and F-2
* Note: 10 mA available only in blue neutral.

Accessory
Type
Padlocking device (bag of 10 pieces) A9A27049

B-40 Acti 9 | Catalogue 2014


Protect iC60H2 RCBO
Circuit protection 10000 A (30 and 300mA)

IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1


PB111076-70

■ The 2-poles iC60H2 RCBO’s self-contained residual current device carries out
■ complete protection of final circuits:
□ protection against short-circuits and cable overloads,
□ protection of persons against electric shock by direct contact
(30 mA sensitivities),
□ protection of equipment against fires set by leakage currents
(300 mA sensitivity).
■ iC60H2 RCBO switches neutral, together with phase. It is therefore suitable for all circuits, whatever the earthing
system (except for TN-C).

Alternating current (AC) 50/60 Hz


Breaking capacity (Icn) according to IEC 61009-1
Voltage (Ue)
Ph/N, Ph/Ph 110 V 240 V
Rating (In) 10 to 32 A 10000 A 10000 A

Catalogue numbers
iC60H2 RCBO 10000
2P A Width in 9-mm
modules
C curve Voltage rating (V) Sensitivity (IΔn) 30 mA 300 mA
240 Rating 10 A A9D11210 A9D51210 4
DB405040

(In) 16 A A9D11216 A9D51216


20 A A9D11220 A9D51220
25 A A9D11225 A9D51225
32 A A9D11232 A9D51232

Operating frequency
Auxiliaries Refer to Page E-2 and F-2 of the
Acti 9 catalogue
Accessories padlocking device ( bag of 10 pcs.) A9A27049

Acti 9 | Catalogue 2014 B-41


Protect iC60 RCBO
Circuit protection 10, 30 and 100 mA

Technical data
Main characteristics iC60N RCBO iC60H RCBO iC60H2 RCBO
Insulation voltage (Ui) 400 V AC
Rated impulse withstand voltage (Uimp) 4 kV
Rated residual operating current (IΔn) 30 mA 10, 30, 100 mA 30 mA, 300 mA
Thermal tripping Reference temperature 50°C
Temperature derating See the Technical Guide
Limitation class 3
Surge current withstand (8/20 μs) without tripping 250 Â
Rated nominal breaking capacity (Icn) 6,000 A 10,000 A 10,000 A
Phase/earth rated residual breaking and making capacity (IΔm) 6,000 A 7,500 A 7,500 A
Additional characteristics
Degree of protection Device only IP20
Device in modular enclosure IP40
Endurance (O-C) Electrical 5,000 cycles
Mechanical 20,000 cycles
Operating temperature -15°C to +60°C
Storage temperature -40°C to +85°C
Tropicalization Treatment 2 (relative humidity: 95 % at 55°C)

IP20 IP40
DB404953
DB123309

DB123313

Clip on DIN rail 35 mm.


Installation on Fishbone.
DB123311

Weight (g)
Indifferent position of installation.
iC60 RCBO
iC60N RCBO 205
iC60H RCBO 205
iC60H2 RCBO 332

Dimensions (mm)
72 72
DB405565

45 19 45 19
18 36

20 20

5.5 5.5
45 45
110 110

55 15 55 15
iC60N RCBO, iC60H RCBO iC60H2 RCBO

B-42 Acti 9 | Catalogue 2014


Load Protection
(Surge arrester)

Acti 9 | Catalogue 2014 C-1


Protection iPF surge arresters
Load protection Type 2 or 3 LV surge arresters

The iPF multi-pole single-piece surge arrester Each surge arrester in the range has a specific application:
range is adapted for earthing systems: TT, TN-S, b incoming protection (type 2):
TN-C. v the iPF65(r) is recommended for a very high risk level (strongly exposed site)
v the iPF40(r) is recommended for a high risk level
Type 2 surge arresters are tested with a 8/20 μs
v the iPF20 is recommended for a medium risk level
current wave. b secondary protection (type 2 or 3):
Type 3 surge arresters are tested with a 12/50 μs v the iPF8 ensures secondary protection of loads to be protected and is placed in
and 8/20 μs combined wave. cascade with the incoming surge arresters. This surge arrester is required when the
loads to be protected are at a distance of more than 30 m from the incoming surge
arrester.

The iPF surge arresters with “r” indication have remote transfer of the information:
“surge arrester to be replaced”.

Rated discharge Type of protection Network


current (Imax) /

DB122942

DB122943
Nominal discharge
current (In)

Incoming Secondary 1P+N 3P+N 1P 2P 3P 4P


(type 2 or 3)
65 kA / 20 kA
PB105278-35

iPF65 A9L15683
A9L15684
A9L15584
A9L15581
A9L15685
A9L15586
A9L15585
40 kA / 15 kA
High risk level iPF40 A9L15686
A9L15687
1P+N. A9L15587
A9L15582
A9L15690
A9L15688
A9L15590
PB105280-35

A9L15588
20 kA / 5 kA
Medium risk level iPF20 A9L15691
A9L15692
A9L15592
A9L15597
A9L15693
A9L15593
8 kA / 2.5 kA
Secondary protection: iPF8 A9L15694
3P+N. placed near the loads to be A9L15695
protected when they are at a A9L15595
distance of more than 30 m
from the incoming surge A9L15598
arrester A9L15696
A9L15596

Surge arrester/circuit breaker association


Type of surge arrester Associated circuit breaker
iPF65 Curve C 50 A
iPF40 Curve C 40 A
iPF20 Curve C 25 A
iPF8 Curve C 20 A

C-2 Acti 9 | Catalogue 2014


Protection iPF surge arresters
Load protection Type 2 or 3 LV surge arresters (cont.)

Earthing Transfer Surge Width Up - (kV) Un - (V) Uc - (V)


system arrester in mod. Voltage protection level Rated Maximum continuous
name of 9 mm voltage operating voltage
network
CM* DM* CM* DM*

L/t N/t L/N L/t N/t L/N

iPF65
TT & TN iPF65 1P 2 y 1.5 - - 230 340 - -
TT & TN-S iPF65 1P+N 4 - y 1.5 y 1.5 - 260 340
TN-C iPF65 2P y 1.5 y 1.5 - 340 340 -
TN-C iPF65 3P 8 y 1.5 - - 230/400 340 - -
TT & TN-S b iPF65r 3P+N - y 1.5 y 1.5 - 260 340
TT & TN-S iPF65 3P+N - y 1.5 y 1.5 - 260 340
TN-C b iPF65r 4P y 1.5 y 1.5 - 340 340 -
iPF40
TT & TN iPF40 1P 2 y 1.5 - - 230 340 - -
TT & TN-S iPF40 1P+N 4 - y 1.5 y 1.5 - 260 340
TN-C iPF40 2P y 1.5 y 1.5 - 340 340 -
TN-C iPF40 3P 8 y 1.5 - - 230/400 340 - -
TT & TN-S b iPF40r 3P+N - y 1.5 y 1.5 - 260 340
TT & TN-S iPF40 3P+N - y 1.5 y 1.5 - 260 340
TN-C b iPF40r 4P y 1.5 y 1.5 - 340 340 -
TN-C iPF40 4P y 1.5 y 1.5 - 340 340 -
iPF20
TT & TN iPF20 1P 2 y 1.1 - - 230 340 - -
TT & TN-S iPF20 1P+N 4 - y 1.5 y 1.1 - 260 340
TN-C iPF20 2P y 1.1 y 1.1 - 340 340 -
TN-C iPF20 3P 8 y 1.1 - - 230/400 340 - -
TT & TN-S iPF20 3P+N - y 1.5 y 1.1 - 260 340
TN-C iPF20 4P y 1.1 y 1.1 - 340 340 -
iPF8 (1) Type 2 / Type 3

C
TT & TN iPF8 1P 2 y 1 / y 1.1 - - 230 340 - -
TT & TN-S iPF8 1P+N 4 - y 1.5 / y 1.2 y 1 / y 1.1 - 260 340
TN-C iPF8 2P y 1 / y 1.1 y 1 / y 1.1 - 340 340 -
TN-C iPF8 3P 8 y 1 / y 1.1 - - 230/400 340 - -
TT & TN-S iPF8 3P+N - y 1.5 / y 1.2 y 1 / y 1.1 - 260 340
TN-C iPF8 4P y 1 / y 1.1 y 1 / y 1.1 - 340 340 -
* CM: common mode (phase to earth and neutral to earth). * DM: differential mode (phase to neutral). (1) Uoc: combinated waveform voltage: 10 kV.

Acti 9 | Catalogue 2014 C-3


Protection iPF surge arresters
Load protection Type 2 or 3 LV surge arresters (cont.)

Connection
Type Tightening Copper cables
DB123129

torque Rigid Flexible or ferrule


11 mm
6.5 mm

DB122945

DB122946
PZ2

iPF8 / 20 Ph / N 1.2 N.m 16 mm2 max. 10 mm2 max.


t 2 N.m 25 mm2 max. 16 mm2 max.

iPF40 / 65 Ph / N 2 N.m 25 mm2 max. 16 mm2 max.


DB123129

t 3.5 N.m 50 mm2 max. 35 mm2 max.


16 mm
6.5 mm
PZ2

Technical data
Main characteristics
Operating frequency 50/60 Hz
Operating voltage (Ue) 230/400 V AC
Permanent operating current (Ic) < 1 mA
Response time < 25 ns
End of life indication: Green In operation
by green/red mechanical indicator Red At end of life
End of life remote indication By contact NO, NC 250 V / 0.25 A
Additional characteristics
Operating temperature -25°C to +60°C
Type of connection terminals Tunnel terminals, 2.5 to 35 mm²
Standards IEC 61643-1 T2 and EN 61643-11 Type 2

Weight (g)
Surge arrester
Type iPF
1P 125
2P 210
3P 335
4P 420

Dimensions (mm)
DB123595

1P 1P+N 3P
2P 3P+N
4P

C-4 Acti 9 | Catalogue 2014


Protection iPRD surge arresters
Load protection Type 2 or 3 LV withdrawable surge
arresters

iPRD withdrawable Rated discharge Type of Network


surge arresters allow current (Imax) / protection

DB122942

DB122943
quick replacement of Nominal discharge
damaged cartridges. current (In)

Incoming Secondary 1P+N 3P+N 1P 2P 3P 4P


65 kA / 20 kA
PB105274-35

Very high risk level iPRD65 A9L16555


(strongly exposed site) A9L16556
A9L16557
A9L16442
A9L16558
A9L16443
A9L16559
A9L16659
40 kA / 15 kA
1P+N High risk level iPRD40 A9L16561
A9L16566
A9L16562
A9L16567
A9L16444
A9L16667
PB105275-35

A9L16445
A9L16568
A9L16563
A9L16564
A9L16569
A9L16597
A9L16664
A9L16669
20 kA / 5 kA
Medium risk level iPRD20 A9L16571
3P A9L16672
A9L16572
A9L16446
A9L16447
A9L16573
A9L16674
PB105276-35

A9L16574
A9L16599
A9L16673
8 kA / 2.5 kA
Secondary protection: iPRD8 A9L16576
placed near the loads to be A9L16677
protected when they are at a A9L16577
distance of more than 30 m
from the incoming surge A9L16448

C
arrester A9L16449
A9L16578
3P+N A9L16679
A9L16579
A9L16678
A9L16680
PB105272-35

Spare cartridges Surge arrester/circuit breaker association


Type Spare cartridges for Cat. no Type of surge arrester Associated circuit breaker
C 65-460 iPRD65r IT A9L16682 iPRD65 Curve C 50 A
C 65-340 iPRD65r A9L16681 iPRD40 Curve C 40 A
C 40-460 iPRD40r IT A9L16684 iPRD20 Curve C 25 A
C 40-340 iPRD40, iPRD40r A9L16685 iPRD8 Curve C 20 A
C 20-460 iPRD20r IT A9L16686
C 20-340 iPRD20, iPRD20r A9L16687
C 8-460 iPRD8r IT A9L16688
C 8-340 iPRD8, iPRD8r A9L16689
Cartridge C neutral All products A9L16691

Acti 9 | Catalogue 2014 C-5


Protection iPRD surge arresters
Load protection Type 2 or 3 LV withdrawable surge
arresters (cont.)

Earthing Transfer Surge Width Up - (kV) Un - (V) Uc - (V)


system arrester in mod. Voltage protection level Rated Maximum continuous
name of 9 mm voltage operating voltage
network
CM* DM* CM* DM*

L/t N/t L/N L/t N/t L/N


iPRD65
IT b iPRD65r 1P IT 2 y2 - - 230 460 - -
TT & TN b iPRD65r 1P y 1.5 - - - 340 - -
TT & TN-S b iPRD65r 1P+N 4 - y 1.5 y 1.5 - - 260 340
TN-C b iPRD65r 2P y 1.5 y 1.5 - - 340 340 -
IT b iPRD65r 3P IT 6 y2 - - 230/400 460 - -
TN-C b iPRD65r 3P y 1.5 - - - 340 - -
TT & TN-S b iPRD65r 3P+N 8 - y 1.5 y 1.5 - - 260 340
TN-C b iPRD65r 4P y 1.5 y 1.5 - - 340 340 -
iPRD40
TT & TN b iPRD40r 1P 2 y 1.4 - - 230 340 - -
TT & TN iPRD40 1P y 1.4 - - - 340 - -
TT & TN-S b iPRD40r 1P+N 4 - y 1.4 y 1.4 - - 260 340
TT & TN-S iPRD40 1P+N - y 1.4 y 1.4 - - 260 340
TN-C b iPRD40r 2P y 1.4 y 1.4 - - 340 340 -
TN-C iPRD40 2P y 1.4 y 1.4 - - 340 340 -
TN-C b iPRD40r 3P 6 y 1.4 - - 230/400 340 - -
TN-C iPRD40 3P y 1.4 - - - 340 - -
IT b iPRD40r 3P IT y2 - - - 460 - -
TT & TN-S b iPRD40r 3P+N 8 - y 1.4 y 1.4 - - 260 340
TT & TN-S iPRD40 3P+N - y 1.4 y 1.4 - - 260 340
IT b iPRD40r 4P IT y2 y2 - - 460 460 -
TN-C b iPRD40r 4P y 1.4 y 1.4 - - 340 340 -
TN-C iPRD40 4P y 1.4 y 1.4 - - 340 340 -
iPRD20
TT & TN iPRD20 1P 2 y 1.1 - - 230 340 - -
TT & TN-S b iPRD20r 1P+N 4 - y 1.4 y 1.1 - - 260 340
TT & TN-S iPRD20 1P+N - y 1.4 y 1.1 - - 260 340
TN-C iPRD20 2P y 1.1 y 1.1 - - 340 340 -
TN-C iPRD20 3P 6 y 1.1 - - 230/400 340 - -
IT b iPRD20r 3P IT y 1.6 - - - 460 - -
TT & TN-S b iPRD20r 3P+N 8 - y 1.4 y 1.1 - - 260 340
TT & TN-S iPRD20 3P+N - y 1.4 y 1.1 - - 260 340
IT b iPRD20r 4P IT y 1.6 y 1.6 - - 460 460 -
TN-C iPRD20 4P y 1.1 y 1.1 - - 340 340 -
iPRD8 (1) Type 2 / Type 3
TT & TN iPRD8 1P 2 y1/y1 - - 230 340 - -
TT & TN-S b iPRD8r 1P+N 4 - y 1.4 / y 1 y 1 / y 1.1 - - 260 340
TT & TN-S iPRD8 1P+N - y 1.4 / y 1 y 1 / y 1.1 - - 260 340
TN-C iPRD8 2P y1/y1 y1/y1 - - 340 340 -
TN-C iPRD8 3P 6 y1/y1 - - 230/400 340 - -
IT b iPRD8r 3P IT y 1.4 / y 1.6 - - - 460 - -
TT & TN-S b iPRD8r 3P+N 8 - y 1.4 / y 1 y 1 / y 1.1 - - 260 340
TT & TN-S iPRD8 3P+N - y 1.4 / y 1 y 1 / y 1.1 - - 260 340
IT b iPRD8r 4P IT y 1.4 / y 1.6 y 1.4 / y 1.6 - - 460 460 -
TN-C iPRD8 4P y1/y1 y1/y1 - - 340 340 -
* CM: common mode (phase to earth and neutral to earth). * DM: differential mode (phase to neutral). (1) Uoc: combinated waveform voltage: 10 kV.

C-6 Acti 9 | Catalogue 2014


Protection iPRD surge arresters
Load protection Type 2 or 3 LV withdrawable surge
arresters (cont.)

Connection
Type Tightening torque Copper cables
DB123130

Rigid Flexible or ferrule


14 mm

DB122945

DB122946
6.5 mm
PZ2

iPRD 2 N.m 2.5 to 25 mm2 2.5 to 16 mm2

Technical data
Main characteristics
Operating frequency 50/60 Hz
Operating voltage (Ue) 230/400 V AC
Permanent operating current (Ic) < 1 mA
Response time < 25 ns
End of life indication: by mechanical White In operation
indicator Red At end of life
End of life remote indication By contact NO, NC 250 V / 0.25 A
Additional characteristics
Operating temperature -25°C to +60°C
Type of connection terminals Tunnel terminals, 2.5 to 35 mm²
Standards IEC 61643-1 T2 and EN 61643-11 Type 2

Weight (g)
Surge arrester
Type iPRD
1P 115
2P 220
3P 340
4P 450

Dimensions (mm)
DB123596

C
1P 1P+N
2P

3P 3P+N
4P

Acti 9 | Catalogue 2014 C-7


Surge protection Withdrawable surge arrester
Load protection
iQuick PRD Type 2 or Type 3

Withdrawable surge arrester iQuick PRD allow


IEC 61643- 1 T2 , EN 61643-11 Type 2
damaged cartridges to be replaced quickly.
They offer remote reporting of the "cartridge They protect electrical and electronic equipment against lightning-induced surges.
must be changed" message. Withdrawable surge arrester iQuick PRD surge arresters are prewired, incorporating
their end-of-life disconnector.
Each surge arrester in the range has a specific use:
b incoming protection (type 2):
v iQuick PRD40r is recommended for a high risk level
PB106430-29

v iQuick PRD20r is recommended for a moderate risk level


b secondary protection (type 2 or 3):
v iQuick PRD8r provides secondary protection for the loads to be protected and is
cascade-mounted with the incoming surge arresters. This surge arrester is required
as close as possible to the loads to be protected when they are located more than
30 metres away from the incoming surge arrester.

Maximum discharge Type of Network


current (Imax) / protection

DB114409

DB114410
Nominal discharge 14

current (In)
PB106429-29

Incoming Secondary 1P+N 3P+N 3P


protection protection
40 kA / 20 kA
High risk level iQuick PRD40r A9L16292
A9L16293
A9L16294
20 kA / 5 kA
Moderate risk level iQuick PRD20r A9L16295
A9L16296
A9L16297
8 kA / 2 kA
PB106428-29

Secondary protection: iQuick PRD8r A9L16298


placed near the loads to be A9L16299
protected when they are at a A9L16300
distance of more than 30 m from
the incoming surge arrester
DB123837

Replacement cartridges
Type Replacement cartridges for Cat. no.
C 40-350 iQuick PRD40r A9L16310
C 20-350 iQuick PRD20r A9L16311
C 8-350 iQuick PRD8r A9L16312
C neutral-350 All products A9L16313

Replacement cartridges.

C-8 Acti 9 | Catalogue 2014


Surge protection Withdrawable surge arrester
Load protection
iQuick PRD Type 2 or Type 3

Connection
Type Tightening Copper cables
DB123888

torque Rigid Flexible or ferrule


11 mm
6.5 mm

DB122945

DB122946
PZ2
iQuick PRD Ph / N 8r/20r 2.5 N.m 2.5 to 25 mm2 2.5 to 25 mm2
Ph / N 40r 2.5 to 35 mm2 2.5 to 35 mm2
t 25 mm2 max. 25 mm2 max.

Earthing Transfert Name of Width in Up – (kV) Un – (V) Uc – (V)


system surge 9 mm Voltage protection level Nominal mains Maximum continious
arrester modules voltage operating voltage
CM* DM* CM* DM*

L/t N/t L/N L/t N/t L/N

iQuick PRD40r
TT & TN-S b 1P+N 8 1.5 1.5 2.5 230 - 264 350
TN-C & IT 230 V b 3P 13 2 - - 230/400 350 - -
TT & TN-S b 3P+N 15 1.5 1.5 2.5 - 264 350
iQuick PRD20r
TT & TN-S b 1P+N 8 1.5 1.5 1.5 230 - 264 350
TN-C & IT 230 V b 3P 13 1.5 - - 230/400 350 - -
TT & TN-S b 3P+N 15 1.5 1.5 1.5 - 264 350
iQuick PRD8r (2) Type 2 / Type 3
TT & TN-S b 1P+N 8 1.5/1.4 1.5/1.5 1.2/1.4 230 - 264 350
TN-C & IT 230 V b 3P 13 1.2/1.4 - - 230/400 350 - -
TT & TN-S b 3P+N 15 1.5/1.4 1.5/1.5 1.2/1.4 - 264 350

* CM common mode (between phase/earth and neutral/earth). * DM: differential mode (between phase and neutral).
(1) Up (MCB + SPD): total value measured between Modular Circuit Breaker (MCB) terminal block and PE surge arrester device terminal block (SPD).
(2) Uoc: open-circuit voltage in combined wave: 10 kV.

C
Accessories
DB123842

Earth terminal block support


Type
Support kit L = 4 blocks Batch of 1
DB107889

25 mm2 terminal block kit L = 1 block Batch of 5


DB107884

Pragma: the earth terminal block needs 1 support kit and


1 terminal block kit.

Acti 9 | Catalogue 2014 C-9


Surge protection Withdrawable surge arrester
Load protection
iQuick PRD Type 2 or Type 3
(cont.)
Technical data
Main characteristics
DB123310

Operating frequency 50/60 Hz


Operating voltage (Ue) 230/400 V AC
Disconnector short-circuit withstand 25 kA (50 Hz)
(Isc)
Permanent operating current (Ic) <1 mA
Response time <25 ns
Status indication By the White Operational
Clip on DIN rail 35 mm. cartridges Red At end of life
By white mechanical indicator/ Operational
handle ON
By red mechanical indicator/ At end of life
handle OFF
Remote indication end of life By the NO/NC remote indication contact 250 V AC / 2 A
Additional characteristics
DB123312

Degree of protection Device only IP20, IK05


Device in modular enclosure IP40
Operating temperature -25°C to +70°C
Storage temperature -40°C to +80°C
Certifications NF,
KEMA KEUR (iQuick PRD 8r, 20r)

Indifferent position of installation.

IP20 IP40 Weight (g)


DB123314

Surge arresters
Type iQuick PRD8r/20r iQuick PRD40r
1P+N 435 445
3P 665 700
3P+N 810 850

Dimensions (mm)
DB123595

1P+N 3P 3P+N

C-10 Acti 9 | Catalogue 2014


Surge protection Surge arrester iQuick PF Type 2
Load protection

EN 61643-11 Type 2, IEC 61643-1 T2 ,


IEC 60364-4-443, IEC 60364-5-534
Protects electrical and electronic equipment against indirect overvoltage due to the
lighting effect.
The iQuick PF multi-pole single-piece surge Coordination with selective version "si" and s types.
arrester range is adapted for earthing systems:
TT, TN-S. The iQuick PF is precabled. It incorporates its end of life safety disconnector and an
earthing terminal block.
Type 2 surge arresters are tested with a 8/20 μs
current wave.
Accessories supplied
PB107103-35

PB107104-35

b Terminal and 16 mm² cable for connection to the earth bar of the enclosure
(supplied mounted)
b 1 lug to crimp for 16 mm² earthing cable
b iQuick PF 1P+N: 2 connection accessories for the electrical link between the
surge arrester and the incoming residual current circuit breaker:
v 1 mounted, centre distance between axes: 9 mm,
v 1 supplied, centre distance between axes: 18 mm.

Maximum discharge Network Earthing Width in 9 Up – (kV) Un – (V) Uc – (V)


current (Imax) / system mm modules Voltage Nominal Maximum
Nominal discharge protection mains continius
current (In) level (*) voltage operating
DB123843

voltage

1P+N 3P+N
10 kA / 5 kA
iQuick PF A9L16617 TT & TN-S 4 1.5 230 275
A9L16618 TT & TN-S 10 1.5 230/400 275
(*) common mode of protection (between phase/earth and neutral/earth) and
differential mode of protection (between phase and neutral).

Remote auxiliary
PB107105-40

IEC 60947-5-1
The remote auxiliary iSR allows to remote the iQuick PF operating status.

Auxiliary
Type Width in mod.
of 9 mm
iSR Contact
3A
Voltage (Ue)
415 V CA A9L16619 1 C
DB122821

11

14 12

Connection
Type Tightening Copper cables
DB123129

torque Rigid Flexible or ferrule


13 mm
DB122945

DB122946

6.5 mm

iQuick PF Ph / N 2 N.m 1 to 16 mm2 1 to 16 mm2


t 10 to 25 mm2 10 to 25 mm2
iSR 1.2 N.m 16 mm2 max. 16 mm2 max.
PZ2

Acti 9 | Catalogue 2014 C-11


Surge protection Surge arrester iQuick PF Type 2
Load protection
(cont.)

Technical data
Main characteristics
DB123310

Operating frequency 50 Hz
Operating voltage (Ue) 230/400 V AC
Integrated breaking capacity (Isc at 50 Hz) 6 kA
Status indication: Mechanical indicator white/ Operational
handle ON
Mechanical indicator red/ At end of life
handle OFF
Clip on DIN rail 35 mm. Remote indication end of life By iSR auxiliary
Additional characteristics
Degree of protection Device only IP20
Device in modular enclosure IP40
Operating temperature -25°C to +70°C
Storage temperature -40°C to +80°C
DB123312

Indifferent position of installation.

IP20 IP40 Weight (g)


DB123314

Surge arresters
Type iQuick PF
1P+N 370
3P+N 640

Dimensions (mm)
DB123848

DB123849

DB123850

1P+N 3P+N iSR

C-12 Acti 9 | Catalogue 2014


Protection iPRC, iPRI surge arresters
Load protection

Analogue telephone line protection: the iPRC surge arrester wired in series to the
DB116619

private installation input protects the telephones, the PABX, the modems
(including ADSL), etc.

Protection for 2 low-current lines without common potential or 4 lines with


common reference potential: the iPRI protects the measuring instrument and PLC
"sensor" inputs and the DC power supply inputs up to 53 V and AC power supply
Protection against overvoltages related to inputs up to 37 V.
lightning strikes. The input current must not exceed 300 mA.
PB104269-35

PB104270-35

DB122585

DB126523
10 4
L'1 L1 L'2 L2

A9L16337 A9L16339
Db122624

L'1 L1 L'2 L2
3 3

Line L1 Cables 7-8 Line L1 Cables 5-6


Line L2 Cables 11-12 Line L2 Cables 11-12
– – Line L’1 Cables 1-2
– – Line L’2 Cables 7-8
t Cable 3 t Cables 3-4-9-10
IN Ligne side IN Ligne side

Catalogue numbers OUT Protected side OUT Protected side

Surge arresters iPRC iPRI


Mains voltage (Un) <130 V AC 48 V DC
Analogue telephone system b –
Telephone transmitter b –
Digital telephone system – b
Automation network – b
VLV load power supply (12…48 V) – b
xDSL compatibility b –
Cat. no.. A9L16337 A9L16339
Width in 9 mm modules 2 2

Diagrams
DB122600

iPRC
C
3

iPRI
Position
switches

iPRI
Analog
sensors

Acti 9 | Catalogue 2014 C-13


Protection iPRC, iPRI surge arresters
Load protection
(cont.)

Connection
Tightening Copper cables

DB122584
torque Rigid Flexible or ferrule
8 mm

3 mm

DB122945

DB122946
PZ1 0.8 N.m 0.2 to 4 mm2 0.2 to 2,5 mm2
DB123309

Technical data
Main characteristics
iPRC iPRI
Number of protected lines 2 2
Test category IEC/VDE C1, C2, C3, D1, B2 C1, C2, C3, D1, B2
Clip on DIN rail 35 mm.
Maximum continuous voltage (Uc) 180 V DC, 130 V AC 53 V DC, 37 V AC
Limitation voltage (Up) 300 V 70 V
Rated discharge current (8/20) (In) 10 kA 10 kA
DB123300

Maximum discharge current (8/20) (Imax) 18 kA 10 kA


Response time < 500 ns y 1 ns
Nominal impulse current 100 A 70 A
Rated current (IN) 450 mA (up to 45°C) 300 mA (up to 45°C)
Series resistor 2.2 Ω 4.7 Ω
End-of-life information by Loss of dialling tone Loss of transmission
± 30° vertical. Additional characteristics
Degree of protection Device only IP20 IP20
Device in modular IP40 IP40
IP20 IP40 enclosure
DB123311

IK 05 05
IK05 IK05 Operating temperature -25°C to +60°C -25°C to +60°C
Storage temperature -40°C to +85°C -40°C to +85°C

Weight (g)
Surge arresters
Type iPRC iPRI
25 65

Dimensions (mm)
DB122585

66
18 52

90 45

C-14 Acti 9 | Catalogue 2014


Protection iPRD-DC surge arresters
Load protection Withdrawable surge arresters type 2 for
photovoltaic applications

IEC 61643-1 T2
e EN 61643-11 Type 2
UTE C 61740-51 T2
prEN 50539-11 T2
PB107585-40

iPRD-DC direct current surge arresters are designed to protect against overvoltages
due to a lightning strike: of the "DC" input to the inverter and of photovoltaic panels.

It should be installed in a switchboard inside the building. If the switchboard is


located outside, it must be weatherproof.

Withdrawable iPRD-DC surge arresters allow damaged cartridges to be replaced


quickly.
They offer remote reporting of the "cartridge must be changed" message.

iPRD-DC40r 600PV

Catalogue numbers
Internal diagram Imax (kA) In (kA) Up (kV) UCPV (V) (1) Width in Cat. no.
Maximum Nominal Protection level Maximum steady state module of
discharge discharge voltage 9 mm
current current
L+/t L-/t L+/L- L+/t L-/t L+/L-
iPRD-DC40r 600PV
40 15 1.6 1.6 2.8 600 600 840 6 A9L16434
DB124051

iPRD-DC40r 1000PV
40 15 3.9 3.9 3.9 1000 1000 1000 6 A9L16436
DB124052

(1) Ucpv u 1.2 x Uoc stc (Uoc stc: maximum no-load voltage of the photovoltaic generator "photovoltaic module manufacturer's data")
C
Replacement cartridges
PB107586-30

PB107587-30

Type Replacement cartridges for Cat. no.


C 40-600PV iPRD-DC40r 600PV A9L16683
C 40-1000PV iPRD-DC40r 1000PV A9L16692
C neutral PV iPRD-DC40r 600PV A9L16690

Replacement cartridges

Acti 9 | Catalogue 2014 C-15


Protection iPRD-DC surge arresters
Load protection Withdrawable surge arresters type 2 for
photovoltaic applications (cont.)

Connection
Type Tightening torque Copper cables
DB124057

Rigid Flexible or ferrule


14 mm
6.5 mm

DB122945

DB122946
PZ2

iPRD-DC 2 N.m 2.5 to 25 mm2 2.5 to 16 mm2

Depending on the distance between the "generator" part and the "conversion" part, it
may be necessary to install two surge arresters or more, to ensure protection of each
of the two parts.
Generator
DB124049

10 m iPRD-DC
1

Generator
Conversion

iPRD-DC
2

10 m

iPRD-DC
1

Conversion

C-16 Acti 9 | Catalogue 2014


Protection iPRD-DC surge arresters
Load protection Withdrawable surge arresters type 2 for
photovoltaic applications (cont.)

Technical data
DB123310

Main characteristics
Type of network Isolated direct current
Temps de réponse < 25 ns
Short circuit current (ISCPV) 30 A
Type of surge arresters Type 2
Clip on DIN rail 35 mm. End-of-life indication mode Circuit opened by integrated thermal
disconnector
Additional characteristics
DB123312

Degree of protection Device only IP20


(IEC 60529) Device in modular IP40
enclosure
Chocs IK03
End-of-life indication By the cartridges White Operational
Red At end of life
By the NO/NC remote indication contact 250 V AC / 0.25 A
Indifferent position of installation. Operating temperature -25°C to +60°C
Storage temperature -40°C to +85°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity
IP20 IP40 of 95 % at 55°C)
DB123314

Weight (g)
Surge arresters
Type
iPRD-DC40r 600PV 400
iPRD-DC40r 1000PV 400

Dimensions (mm)
DB124050

Acti 9 | Catalogue 2014 C-17


C-18 Acti 9 | Catalogue 2014
Disconnection

Acti 9 | Catalogue 2014 D-1


Control iSW switches
Local control

b Insulated terminals IP20

b Large circuit
labelling area

Positive contact indication


b Suitable for industrial isolation according to
IEC/EN 60947-2 standard.
b The presence of the green strip guarantees
physical opening of the contacts and allows
b Clip for dismounting operations to be performed on the downstream
circuit in complete safety

D-2 Acti 9 | Catalogue 2014


Control iSW switches (cont.)
Local control

Position contact indication iSW control switches (20, 32 A)


b Suitable for industrial isolation according to
IEC/EN 60947-3 standard. IEC/EN 60669-1, iSW switch with indicator light.
b The presence of the green strip guarantees IEC/EN 60669-2-4, iSW switch without indicator light.
physical opening of the contacts and allows
operations to be performed on the downstream These switches are used for:
circuit in complete safety. b Control (opening and closing of circuits under load).
The 1P and 2P switches are available with or without indicator light.
PB105266-40

b Disconnection, for switches without indicator light IEC/EN 60669-2-4.

iSW switch-disconnectors (40 to 125 A)

IEC 60947-3
DB122818

The switch-disconnectors combine the following functions:


b Control (opening and closing of circuits under load).

OF iSW auxiliary
b Mounted on the left, it indicates the "open" or "closed" position of the switch and
has a normally open (NO) or normally closed (NC) contact.

Catalogue numbers
20, 32 A iSW control switches
PB105264-40

PB105265-40

Type Width in 9 mm modules


1P Rating Voltage (Ue)
20 A 250 V AC A9S60120 2
DB118998

1
32 A 250 V AC A9S60132

2P
20 A 250 V AC - 2
DB118999

1 3
415 V AC A9S60220
Control switches 32 A 250 V AC -
415 V AC A9S60232
2 4

3P
20 A 415 V AC A9S60320 4
DB119000

1 3 5
32 A 415 V AC A9S60332

2 4 6

4P
20 A 415 V AC A9S60420 4
DB119001

1 3 5 7
32 A 415 V AC A9S60432

2 4 6 8
Operating frequency 50/60 Hz
Accessories See page E-15

Acti 9 | Catalogue 2014 D-3


Control iSW switches
Local control

Catalogue numbers (cont.)


PB105264-40

20, 32 A iSW control switches with indicator light


Type Width in 9 mm modules
1P Rating 230 V indicator light
20 A A9S61120 2

DB122819
1 3
32 A A9S61132

2P
20 A A9S61220 2
DB122820
1 3
32 A A9S61232
Control switches with indicator light

2 4
Operating frequency 50/60 Hz
Accessories See page E-15

Spare indicator lights for 20, 32 A iSW switches


Type
Neon Voltage (Ue)
Supplied with a red diffuser 230 V AC 15111
(Pack of 10)
Incandescent bulb (P=1.2 W)
Supplied with a red diffuser 12 V DC/AC 15112
(Pack of 10) 24 V DC/AC 15113
48 V DC/AC 15114
PB105264-40

Catalogue numbers (cont.)


Auxiliary
Type Width in 9 mm
modules
OF iSW Rating Voltage (Ue)
3A 415 V AC A9A15096 2
DB122821

11
6A 250 V AC

14 12

OF iSW
Technical data
Main characteristics 20, 32 A iSW 40 to 125 A iSW
Insulation voltage (Ui) Without With indicator 1P: 250 V AC
indicator light light 2P, 3P, 4P: 500 V AC
b 1P: 250 V AC 250 V AC
b 2P, 3P, 4P:
500 V AC
Pollution degree 2 3
Power circuit
Rated impulse withstand 4 kV 6 kV
voltage (Uimp)
Operating category AC - 22 A AC - 22 A
Permissible rated short-time - 40 A, 63 A: 1260 A
withstand current (Icw) 100 A, 125 A: 2500 A
Conditional rated short-circuit 3 kA to IEC/EN 60669-2-4 6 kA to IEC 60947-3
current (Inc)
Rated short-circuit closing - 40 A, 63 A: 4.2 kA
current (Icm) 100 A, 125 A: 5 kA
Using direct current 48 V (110 V with 2 poles in series)
IP40
DB123597

Additional characteristics
Degree of protection IP40 on the front panel
Endurance (O-C) Mechanical 300,000 cycles 50,000 cycles
Electrical 30,000 cycles 40, 63 A iSW 20,000 cycles
100 A iSW 10,000 cycles
125 A iSW 2 500 cycles
Operating temperature -20°C to +50°C
Storage temperature -40°C to +70°C
Tropicalization Treatment 2 (relative humidity 95% at 55°C)

D-4 Acti 9 | Catalogue 2014


Control iSW switches (cont.)
Local control

Connection
Type Rating Tightening Copper cables
DB123135

DB123136 torque Rigid Flexible or ferrule


9 mm 9 mm
5 mm 6.5 mm

DB122945

DB122946
PZ1 PZ2

iSW 20, 32 A 1.2 N.m 10 mm2 10 mm2


40 to 125 A 3.5 N.m y 50 mm2 y 35 mm2
OF iSW - 1.2 N.m 10 mm2 10 mm2
20, 32 A iSW 40 to 125 A iSW

Dimensions (mm)
DB122822

1P, 2P 3P, 4P
20, 32 A iSW

4P
DB122823

3P
2P
1P

40 to 125 A iSW
DB122824

OF iSW

Acti 9 | Catalogue 2014 D-5


Control iSW switches
Local control

IEC/EN 60947-3
DB116619

BSEN 60947-3
AS/NZS 60947-3
The switch-disconnectors combine the following functions:
b Control (opening and closing of circuits under load).

iOF auxiliary
b Mounted on the left, it indicates the "open" or "closed" position of the switch and
has a normally open (NO) or normally closed (NC) contact.
PB110909

PB110910

Catalogue numbers
40 to 125 A iSW switch-disconnectors
Type Width in 9 mm
modules
1P Rating Voltage (Ue)
40 A 240 V AC A9S66140 2
DB118998

1
63 A 240 V AC A9S66163
100 A 240 V AC A9S66191
125 A 240 V AC A9S66192
2
1P 2P
2P
40 A 415 V AC A9S66240 4
DB118999

1 3
63 A 415 V AC A9S66263
100 A 415 V AC A9S66291
PB110911

PB110912

125 A 415 V AC A9S66292


2 4

3P
40 A 415 V AC A9S66340 6
DB119000

1 3 5
63 A 415 V AC A9S66363
100 A 415 V AC A9S66391
125 A 415 V AC A9S66392
2 4 6

3P+N
N 1 3 5 125 A 415 V AC A9S66792 8
DB404563

3P 4P

N 2 4 6

4P
40 A 415 V AC A9S66440 8
DB119001

1 3 5 7
63 A 415 V AC A9S66463
100 A 415 V AC A9S66491
125 A 415 V AC A9S66492
2 4 6 8
Operating frequency 50/60 Hz
Accessories See pages E-2 and E-10

Auxiliary
PB104474-35

Type Width in 9 mm
modules
iOF Voltage (Ue)
240...415 V AC A9A26924 1
DB118810

24...130 V DC

D-6 Acti 9 | Catalogue 2014


Protection NG125NA switches
Switch up to 125 A

For rating u 80 A
b Voltage taps:
v auxiliaries power supply
v measurement
v emergency stop
v remote reporting

b Cable strength:
v ribbed cage
v terminal depth b Integrated padlocking
v tightening by Allen hex device
key (NG125 ≥ 80 A)
056909N_SE-1811-90

b Test button to check


satisfactory operation of
the tripping mechanism

b Pull-out strength:
v metallic lock

b Central manual control, 3


positions:
b Impact and vibration resistance: v ON
v high-strength enclosure v tripped on fault
v IK 05 v open

b Circuit breaker tripped indicator

b Electric power supply


through the top or bottom
b Positive contact indication:
DB123493

v suitability for isolation in the industrial sector to IEC/EN 60947-3;


v the presence of the green strip guarantees that the contacts open physically
and allows work to be carried out safely on the downstream circuit.

b Longer product service life due to:


v good overvoltage withstand capacity;
v high limitation performances;

D
v fast closure independent of the speed of actuation of the toggle.

Acti 9 | Catalogue 2014 D-7


Protection NG125NA switches (cont.)
Switch up to 125 A

IEC/EN 60947-3
DB116619

b The NG125NA is a switch-disconnector with free tripping for making and breaking
under load.
b It is especially suitable for the modular enclosure incoming feeder with remote
breaking (e.g. emergency cutoff).
056908N_SE-1811-35

056909N_SE-1811-35

NG125NA 3P NG125NA 4P

Catalogue numbers
NG125NA switch
Type 3P 3P+N
1 3 5 1 3 5 7

2 4 6 2 4 6 8

Auxiliaries Remote indication and tripping, see page F-14


Rating (In) Quality label
(1)
63 A 18889 18893
80 A 18890 18894
100 A 18891 18895
125 A 18892 18896
Width in 9 mm modules 9 12
Accessories See page E-26

(1) Information to be supplied by the country concerned.

D-8 Acti 9 | Catalogue 2014


Protection NG125NA switches (cont.)
Switch up to 125 A

Connection Without With


accessories accessories
Rating Tightening Copper cables 70 mm2 Screw-on Small Multi-cable
DB122861

NG125
u 80 A torque Al connection ring terminal
20 mm
Rigid Flexible or terminal for ring terminal Rigid Flexible
with terminal cables cables
ferrule

DB122945

DB122946

DB123410

DB123488

DB118789

DB118787
PZ2
6.5 mm 6 mm
NG125
y 63 A 63 A 3.5 N.m 1.5 to 50 mm2 1 to 35 mm2 - - - 3 x 16 mm2 3 x 10 mm2
80 to 6 N.m 16 to 70 mm2 10 to 50 mm2 25 to 70 mm2 2 x 35 mm2 1 x 70 mm2
125 A 1 x 50 mm2
b For rating u 80 A: upstream voltage taps for each pole, by 6.35 mm Fast-on terminal.

Technical data
Main characteristics
DB123310

According to IEC/EN 60947-3


Max. voltage rating (Ue) 500 V AC
Insulation voltage (Ui) 690 V AC
Degree of pollution 3
Rated impulse withstand voltage (Uimp) 8 kV
Short time withstand current (50 ms) Icw 1.5 kA
Clips onto 35 mm DIN rail.
Rated short-circuit closing current (Icm) 2 kA
Utilization category AC22A/B - AC23B
DB123312

Additional characteristics
Degree of Device only IP20
protection Device in modular enclosure IP40
(IEC 60529)

Endurance (O-C) Category A Category B


Electrical y 100 A 1500 cycles 300 cycles
(except AC20 and DC20)
Any installation position. 125 A 1000 cycles 200 cycles
Mechanical 20,000 cycles
Operating temperature -30°C to +70°C
IP20 IP40
DB123314

Storage temperature -40°C to +70°C


Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95% at 55°C)

Weight (g)
Switch
Type NG125NA
3P 720
4P 960

Dimensions (mm)

27.75 25.5 27.75 79.5 28.5


DB123487
DB122588

D
16.25 16.25

70.5 70.5

16.25 16.25

53.25 28.5 51

Spacing for mounting on panel

Acti 9 | Catalogue 2014 D-9


D-10 Acti 9 | Catalogue 2014
Install,
Connection E

and Power
Distribution

Acti 9 | Catalogue 2014 E-1


Protection Accessorisation / Auxiliarisation
Circuit protection
Earth leakage protection iC60, iID, Vigi iC60, iSW-NA

Connection accessories

DB123735
See page E-10
8 Splitter blocks Multiclip See page E-24
Distribloc See page E-22 9 10 11
9 50 mm² Al terminal 27060
10 Screw-on connection for ring terminal 27053
11 Multi-cables terminal 4 parts 19091 8
3 parts 19096
12 Comb busbar See page E-18

12

Mounting accessories
See page E-10
13 Sealable terminal shields 1P (set of 2) A9A26975
for top and bottom connection 2P (set of 2) A9A26976
3P 1P + 2P
4P 2P + 2P 13 14 15 15’ 16 17
14 Interpole barrier (set of 10) A9A27001
15 Screw shields 4P (set of 20) A9A26981
15''Screw shields Vigi iC60 (set of 12) A9A26982
16 Clip-on terminal markers See page E-10
17 9 mm spacer A9A27062
18 Padlocking device (set of 10) A9A26970
19 Plug-in base A9A27003
20 Rotary handle
Black handle A9A27005
Red handle A9A27006
18 19
No handle A9A27008

Electrical auxiliaries
See page F-2
Indication
4 iOF/SD+OF auxiliary contact A9A26929
(OF+SD or OF+OF combination switch) 20
5 iSD fault indicating contact A9A26927
6 iOF open/close auxiliary contact A9A26924
7 iOF+SD24 auxiliary contact A9A26897 Auxiliary contacts Tripping devices

Tripping devices
2 iMN undervoltage release See page F-2
or iMNs undervoltage release
delayed or iMNx
undervoltage release with
external feeding
3 Shunt release iMX, iMX+OF See page F-2
overvoltage release iMSU 4-5-6-7 2-3

Vigi iC60

d
See page F-9
Tripping devices must be mounted first.
1 Vigi iC60 add-on residual See page B-17
current device Respect specified position for SD functions.

E-2 Acti 9 | Catalogue 2014


Protection Accessorisation / Auxiliarisation
Circuit protection
Earth leakage protection Reflex iC60

Connection accessories
E

DB404783
See page E-10
3 Splitter blocks Multiclip See page E-24
Distribloc See page E-22
4 5 6
4 50 mm² Al terminal 27060
5 Screw-on connection for ring terminal 27053
6 Multi-cables terminal 4 parts 19091
3 parts 19096 3

7 Comb busbar See page E-18

Mounting accessories
See page E-10
8 Sealable terminal shields 1P (set of 2) A9A26975
for top and bottom connection 2P (set of 2) A9A26976
3P 1P + 2P
4P 2P + 2P
9 Interpole barrier (set of 10) A9A27001 8 9 10 11 12
10 Screw shields 4P (set of 20) A9A26981
11 Clip-on terminal markers See page E-10
12 9 mm spacer A9A27062
13 Padlocking device (set of 10) A9A26970

13

Electrical auxiliary
See page F-2
Control
2 iMDU voltage matching auxiliary A9C18195 iMDU Reflex iC60

Vigi iC60 2
See page F-9
1 Vigi iC60 add-on residual See page B-17
current device

Acti 9 | Catalogue 2014 E-3


Protection Accessorisation / Auxiliarisation
Circuit protection
Earth leakage protection ARA and RCA

Electrical auxiliaries
See page F-2
Indication
2 iOF/SD+OF auxiliary contact A9A26929
(OF+SD or OF+OF combination switch)
3 iSD fault indicating contact A9A26927
4 iOF open/close auxiliary contact A9A26924
5 iOF+SD24 auxiliary contact A9A26897

Tripping devices
6+ iMN undervoltage release See page F-2
or iMNs undervoltage release
delayed or iMNx undervoltage
release with external feeding
7 Shunt release iMX, iMX+OF See page F-2
overvoltage release iMSU
Control
8 iMDU voltage matching auxiliary A9C18195
DB404784

ARA

Auxiliary contacts Tripping devices

ARA

2-3-4-5 6-7

Auxiliary contacts Tripping devices


RCA

2-3-4-5 6-7
iMDU

8
Vigi iC60
See page F-9
1 Vigi iC60 add-on residual
current device
See page B-17 d Tripping devices must be mounted first.
Respect specified position for SD functions.

E-4 Acti 9 | Catalogue 2014


Control Accessorisation / Auxiliarisation
Local control
iSW

Connection accessories
E

DB404785
See page E-10
2 Splitter blocks Multiclip See page E-24
Distribloc See page E-22 3 4 5
3 50 mm² Al terminal 27060
4 Screw-on connection for ring terminal 27053
5 Multi-cables terminal 4 parts 19091 2
3 parts 19096
6 Comb busbar See page E-18

Mounting accessories
See page E-10
7 Sealable terminal shields 1P (set of 2) A9A26975
for top and bottom connection 2P (set of 2) A9A26976
7 8 9 10
3P 1P + 2P
4P 2P + 2P
8 Interpole barrier (set of 10) A9A27001
9 Clip-on terminal markers See page E-10
10 9 mm spacer A9A27062
11 Padlocking device (set of 10) A9A26970
12 Plug-in base A9A27003
13 Rotary handle
Black handle A9A27005
Red handle A9A27006
11 12
No handle A9A27008

Electrical auxiliaries
See page F-2 13
Indication iSW
1 iOF open/close auxiliary contact A9A26924

Acti 9 | Catalogue 2014 E-5


Protection Accessorisation / Auxiliarisation
Circuit protection
Earth leakage protection iDPN Vigi

Connection accessories
See page E-10

DB124421
6 Screw-on connection for ring 27053
terminal
7 Comb busbar See page E-29
6 7 8

Mounting accessories
See page E-10
8 Padlocking device (set of 10) A9A26970
9 Clip-on terminal markers See page E-10
10 9 mm spacer A9A27062

9 10

Auxiliary contacts Tripping devices


iDPN Vigi
Electrical auxiliaries
See page F-2
Indication
2 iOF/SD+OF auxiliary contact A9A26929
(OF+SD or OF+OF combination switch)
3 iSD fault indicating contact A9A26927
4 iOF open/close auxiliary contact A9A26924 2-3-4-5 1
5 iOF+SD24 auxiliary contact A9A26897

Tripping devices
1 iMN undervoltage release See page F-2
or iMNs undervoltage release
delayed or iMNx

d
undervoltage release with
external feeding or shunt Tripping devices must be mounted first.
release iMX, iMX+OF Respect specified position for SD functions.
overvoltage release iMSU

E-6 Acti 9 | Catalogue 2014


Protection Accessories and Auxiliaries for
Circuit protection
Earth leakage protection C120 and Vigi C120 devices

Connection accessories
See page E-15 E

DB123945
7 Multi-cable terminal 4 parts 19091
3 parts 19096
11 10 9 8 7
8 Screw-on connection for ring 8 parts 27053
terminal
9 Terminal for rear connector 18528
10 50 mm² Al terminal 27060
11 Comb busbar See page E-28

Mounting accessories
See page E-15
12 13 14 15 16
12 Sealable terminal shields for 1P (set of 2) 18526
top and bottom connection
13 Interpole barrier (set of 10) 27001
14 Screw shields 4P (set of 2) 18527
15 Clip-on terminal markers See page E-15
16 9 mm spacer A9N27062
17 Padlocking device 27145
18 Plug-in base (1) 26997
19 Rotary handle
Removable extended handle 27047
Fixed handle 27048
Operating sub-assembly (2) 27046
(1) For 1P, centreline between two rows: 200 mm 17 18/ 19
(2) A complete rotary handle consists of a circuit-breaker
operating sub-assembly, cat. no. 27046, a handle cat. no.
27047 or a handle cat. no. 27048. Indication Tripping devices
C120 Vigi C120

Electrical auxiliaries
See page F-9
Indication
3 SD fault indicating contact A9N26927
4 OF+SD24 auxiliary contact A9N26899 3-4-5-6 2 1
5 OF open/close auxiliary contact A9N26924
6 OF/SD+OF auxiliary contact A9N26929
(OF+SD or OF+OF combination switch)

Tripping
2 MN, MNx, MNs See page F-9
undervoltage release,
MSU overvoltage release or
MX, MX + OF shunt release

Vigi C120
d Tripping devices must be mounted first.

See page B-22


1 Vigi C120 add-on residual See page B-22
current device

Acti 9 | Catalogue 2014 E-7


Protection Accessories and Auxiliaries for
Circuit protection
Earth leakage protection C60H-DC devices

Connection accessories
See page E-15

7 Insulated connector See page E-15 7

DB124115
9 10 12
8 Comb busbar See page E-18
9 Terminal 50 mm2 Al / Cu 27060
10 Ring tongue terminal screw connection 27053
11 Ring tongue terminal connections kit 17400
Ø 5 mm, (upstream/downstream) 8 11
12 Insulated distribution terminal 4 pieces 19091
3 pieces 19096

Mounting accessories
See page E-15
13 14 15 16
13 Sealable terminal shield See page E-15
14 Inter-pole barrier 27001
15 Rotary handle
Switching sub-assembly 27046
Disconnectable handle 27047
Fixed handle 27048
16 Screw shield See page E-15
17 Padlocking accessory 26970 17 18 20
(to be locked in the "open" position)
18 Spacer A9N27062
19 Dividable mounting plate 26996
20 Marker strip See page E-15 19

Electrical auxiliaries Indication Tripping devices


See page F-9

Indication
3 SD fault indicating switch A9N26927
4 OF+SD24 auxiliary contact A9N26899
5 OF open/closed contact A9N26924
6 OF/SD+OF auxiliary contact A9N26929
(OF+SD or OF+OF combination switch) 3-4-5-6 1-2

Tripping
1 MN, MNx, MNs See page F-9
undervoltage release
2 MX, MX + OF shunt release See page F-9
b The electrical auxiliaries must be installed to the left of the circuit

d
breaker.
b If the auxiliary SD contacts are associated with the tripping
auxiliaries (MN, MX, etc.), they must be installed to the left of these
auxiliaries.

E-8 Acti 9 | Catalogue 2014


Control Accessories and Auxiliaries for
Local control
iSW 40 to 125 A devices

Connection accessories
See page E-15 E
1 Insulated connector See page E-15 1 3 4 6

DB124198
2 Comb busbar See page E-18
3 Terminal 50 mm2 Al / Cu 27060
4 Ring tongue terminal screw connection 27053
5 Ring tongue terminal connections kit 17400
Ø 5 mm, (upstream/downstream) 2 5
6 Insulated distribution terminal 4 pieces 19091
3 pieces 19096

Mounting accessories
See page E-15
7 8 9 10
7 Sealable terminal shield See page E-15
8 Inter-pole barrier 27001
9 Rotary handle
Switching sub-assembly 27046
Disconnectable handle 27047
Fixed handle 27048
10 Screw shield See page E-15
11 Padlocking accessory 26970 11 12
(to be locked in the "open" position)
12 Spacer A9N27062
13 Dividable mounting plate 26996
13

Electrical auxiliaries
Indication
14 OF iSW open/closed contact A9A15096 14 iSW 40...125 A

Acti 9 | Catalogue 2014 E-9


Protection Accessories for iC60, iID ,
Circuit protection
Earth leakage protection iDPN Vigi, iSW-NA, Reflex iC60,
RCA, ARA, iSW
Mounting
Accessories Rotary handle Plug-in base Padlocking device
PB104509-35

PB104508-35

PB104492-15
DB123599
PB106297_10

Function
Front or side-mounted control b The Laser Square Allows a breaker to be removed or Used to padlock breaker in open
b Degree of protection: IP55 rotary tool brings the replaced quickly, without handling or closed position
handle accurency to align the the connections b Padlock diameter: 3 to 6 mm
b Installation: circuit breaker and the b Degree of protection: IP20 b Sealable
v the control mechanism is mounted on rotary handle b Consists of: (max. diameter: 1.2 mm)
the device v a base to be fastened on a rail b Locking in ON position does not
v the rotary handle is fixed to the front or (or panel) prevent tripping of the breaker in
side of the enclosure v 2 "blades" to be fastened in the the event of faults
b Front-mounted (on door or faceplate) device's terminals b Suitable for IEC/EN 60947-2
b Prevents the door from opening when b Connection: tunnel terminals for compliant disconnection
the device is in the ON position (can be cable up to 35 mm2 rigid, 25 mm2
deactivated) flexible,
b Can be padlocked when the device is b Installation:
in the "open" position (can be padlocked v in universal enclosure
with the device in the "closed" position v on horizontal rail
subject to adaptation) b Height: 178 mm
b Can be locked by padlock of b Not compatible with Vigi iC60 and
(dia. 5 to 8 mm), not supplied with the auxiliaries
device b Can be locked by padlock of
b Pushbutton: iID test available in the (dia. 6 mm), not supplied with
front face of the rotary handle the device
Catalogue A9A27005 A9A27006 A9A27008 GVP01 A9A27003 A9A26970
numbers Operating sub-assembly (1 per pole)

+ +
Black handle Red handle No handle
Set of 1 1 1 1 1 10
Suitability
iC60 b 2P, 3P, 4P b b
iSW b 2P, 3P, 4P b b
iC60 + Vigi iC60 b 2P, 3P, 4P – b
iID b b y 63 A b
iDPN Vigi – – b
Reflex iC60 or – – b
RCA+iC60 or
ARA+iC60
ARA+iID – – b
iSW-NA b b b

E-10 Acti 9 | Catalogue 2014


Protection Accessories for iC60, iID ,
Circuit protection
Earth leakage protection iDPN Vigi, iSW-NA, Reflex iC60,
RCA, ARA, iSW (cont.)

Accessories
Security
Screw shield Terminal shield Inter-pole barrier Spacer
E
PB104489-14

PB104488-14

PB104502-35

PB104503-35

PB104484-30

PB104483-35
Function
Prevents any contact with the connecting Prevents any contact with the Enhances insulation b Used to:
screws terminals between connections: v complete rows
b Upgrades degree of protection to IP20D b Upgrades degree of protection cables, terminals, v separate devices.
b Sealable, max. diameter 1.2 mm to IP20D lugs, etc Width: 1 x 9 mm module
b Sealable, max. diameter 1.2 mm b Allows cable routing
b Set of two, for upstream and from one row to another,
downstream terminals (above and below),
b For 3 poles: A9A26975 + A9A26976 up to 6 mm2
b For 4 poles: 2 X A9A26976

Catalogue A9A26982 A9A26981 A9A26975 A9A26976 A9A27001 A9A27062


numbers

Set of 12 x 1 pole 20 x 4 poles (splittable) 2 x 1 pole 2 x 2 poles 10 5


Suitability
iC60 – b b b b b
iSW – – b b b b
Vigi iC60 b – – – – b
iID – b – b b b
iDPN Vigi – – – – – b
Reflex iC60 or – b b b b b
RCA+iC60 or
ARA+iC60
ARA+iID – b – b b b
iSW-NA – b – b b b

Acti 9 | Catalogue 2014 E-11


Protection Accessories for iC60, iID ,
Circuit protection
Earth leakage protection iDPN Vigi, iSW-NA, Reflex iC60,
RCA, ARA, iSW (cont.)
Connection
Accessories Multi-cable terminal 50 mm² terminal Al Screw-on connection for
ring terminal
DB118780

DB118781

DB118783
Function
For 3 copper cables: For aluminium cables from For lug tipped cables,
b Rigid up to 16 mm2 16 to 50 mm2 front or rear mounting
b Flexible up to 10 mm2
DB118787

DB118789
DB122935
5 mm

Catalogue 19091 19096 27060 27053


numbers
Set of 4 3 1 8
iC60 y 25 A – – – b
Reflex iC60 y 25 A
iC60 >25 A b b b b
Reflex iC60 40 A,
iSW
Vigi iC60 – – – –
iID b b b b
iDPN Vigi – – – b
iSW-NA b b b b
Tightening torque 2 N.m 10 N.m 2 N.m
Lenght stripping 11 mm 13 mm –
Tools to use Dia. 5 mm or PZ2 Hc 1/5" or 5 mm Dia. 5mm

Marking
Accessories Marker strip
DB118785

Used for connection identification


Catalogue 0: AB1-R0 5: AB1-R5 A: AB1-GA J: AB1-GJ S: AB1-GS +: AB1-R12
numbers 1: AB1-R1 6: AB1-R6 B: AB1-GB K: AB1-GK T: AB1-GT -: AB1-R13
2: AB1-R2 7: AB1-R7 C: AB1-GC L: AB1-GL U: AB1-GU blank: AB1-RV
3: AB1-R3 8: AB1-R8 D: AB1-GD M: AB1-GM V: AB1-GV
4: AB1-R4 9: AB1-R9 E: AB1-GE N: AB1-GN W: AB1-GW
F: AB1-GF O: AB1-GO X: AB1-GX
G: AB1-GG P: AB1-GP Y: AB1-GY
H: AB1-GH Q: AB1-GQ Z: AB1-GZ
I: AB1-GI R: AB1-GR
Set of 250
iC60, Reflex iC60, b 4 markers max. per pole
iSW
Vigi iC60 b 4 markers max. per device
iID b 4 markers max. per device
iDPN Vigi b 4 markers max. per device
iSW-NA b 4 markers max. per device

E-12 Acti 9 | Catalogue 2014


Protection Accessories for iC60, iID ,
Circuit protection
Earth leakage protection iDPN Vigi, iSW-NA, Reflex iC60,
RCA, ARA, iSW (cont.)
Dimensions (mm)
19 5 65 E
DB124149

DB124152
96

17
18.5
54

85 75

177

47 75
18.5

88.5

135

Adapter mechanism Handle


360 18.5 10

10

Plug-in base Rotary handle

DB124147
4P 72
DB124146

3P 54
2P 36
1P 18 9

11
25

106

106

31
11

11.5 9

Screw shield 1P (A9A26982) Screw shield 4P (A9A26981)

18 51.5 36 51.5
DB124144

DB124145

35 35
49 49

Terminal shield 1P Terminal shield 2P

4P 72
DB124143

DB124150
DB124148

3P 54
1P+N/2P 36
6 36
15
9 5
20
16

27

81 85 45

17

20 44 18

Inter-pole barrier Padlocking device Spacer

Acti 9 | Catalogue 2014 E-13


Protection Accessories for iC60, iID ,
Circuit protection
Earth leakage protection iDPN Vigi, iSW-NA, Reflex iC60,
RCA, ARA, iSW (cont.)
Rotary handle installation
Dimensions (mm)
56
iC60 3P iC60 4P iID 4P
DB124142

Z Z Z

45° ± 2°

50

17.5
117 2 4.2
6.3
iC60 Z (mm)
2P 25.3 36

2P + Vigi 25.3 36

3P 25.3
3P + Vigi 43 iID Z (mm)
4P 43 2P 25.3
4P + Vigi 43 4P 25.3
F
D = P - 128 mm
GVAPL01
6
159 5 15
3
12 1
112 47

18.5

85 F

18.5
P (mm) F (mm)
D 5
300
166 < P < 500 19 500 11

Rotary handle: front mounted control


DB124141

A
iC60 X (mm) Y (mm)
494 mm - A
2P 44.5 76.8
2P + Vigi 44.5 76.8
3P 44.5 76.8
3P + Vigi 62 94.5
82
4P 62 94.5
Y 4P + Vigi 62 94.5

iID/iSW-NA X (mm) Y (mm)


2P 44.5 76.8
117
4P 44.5 76.8

D D=L-X

44
L 19

Rotary handle: side mounted control

E-14 Acti 9 | Catalogue 2014


Protection Accessories for C120, iSW and
Circuit protection C60H-DC devices
Earth leakage protection

Installation
Accessories Rotary handle Plug-in base Padlocking device E
PB100138_SE-22

056856_SE

056886_SE

057209J_SE-33
PB100137_SE-22

Function
Front or side control of 2, 3 and 4-pole circuit Allows a circuit breaker to be quickly removed Used to padlock a circuit breaker in
breakers or replaced, without touching the connections the "open" or "closed" position
b Degree of protection: IP40 b Degree of protection: IP20 b Diameter of the padlock: 8 mm max.
b A complete rotary handle consists of: b It consists of: b Locking in the ON position does not
v a circuit-breaker operating sub-assembly, cat. v a base to be fixed to a rail (or panel) prevent the circuit breaker from tripping
no. 27046, v 2 “blades” to be fixed in the device terminals in the event of a fault
v a handle cat. no. 27047 or a handle cat. no. b Connection: tunnel terminals for cables up to b Isolation: in conformity
27048 50 mm² (rigid) or 35 mm² (flexible) with IEC/EN 60947-2.
b Installation: b Installation:
v the circuit-breaker operating sub-assembly cat. v on backplate
no. 27046 is fixed to the circuit breaker v on a horizontal rail
v the removable handle cat. no. 27047 is mounted b Centreline between two rows: 200 mm
on the removable front panel or on the enclosure b Only on the circuit breaker, without a Vigi device
door or auxiliary
v the fixed handle cat. no. 27048 is fixed to the b Padlocking option (8 mm dia. padlock not
front or side panel of the enclosure supplied)
Cat. numbers 27047 27048 27046 26996 26997 27145 26970
Removable Fixed Operating (1 per pole) (1 per pole)
extended handle sub-assembly
handle
Set of 1 1 1 1 1 4 2
Suitable for the following devices:
C120 b 2P, 3P, 4P – b b –
C120 + Vigi C120 b 2P, 3P, 4P – – b –
DPN, DPN Vigi b 3P, 4P – – – b
C60H-DC b 2P b – – b
SW60-DC, – – – – b
C60NA-DC,
C60PV-DC
iSW b iSW u at 4 modules of 9 mm b iSW 40 to 63 A – – b

Acti 9 | Catalogue 2014 E-15


Protection Accessories for C120, iSW,
Circuit protection C60H-DC devices (cont.)
Earth leakage protection

Safety
Accessories Screw shield Terminal shield Interpole barrier Spacer
056870_SE-33

PB124114

056869_SE-33

DB123898

PB104483-35
Function
Prevents all contact with the fixing screws Prevents all contact with the terminals Improves the b Used to:
b The degree of protection becomes IP40 b Degree of protection becomes IP40 insulation between the v complete the rows
b Sealable, max. diameter 1.2 mm b Sealable, max. diameter 1.2 mm connections: cables, v separate the devices
b Dividable terminals, lugs, etc. b Width: 1 x 9 mm
module
b Allows that 2 cables
are routed from one row
to another (above and
b 1P b 1P b 2P below), up to 6 mm²

b 3P: 1 x 26975 +
1 x 26976
b 4P: 2 x 26976
Cat. numbers 18527 26981 18526 26975 26976 27001 A9N27062

Set of 2 (4P dividable) 2 (for upstream/downstream terminal) 10 1


Suitable for the following devices:
C120 b – b – – b b
Vigi C120 – – – – – – b
DPN, DPN Vigi – – – – – – b
C60H-DC – b – b b b b
SW60-DC, – b – – – b b
C60NA-DC,
C60PV-DC
iSW – b iSW 40 to 125 A – b iSW 40 to 125 A b iSW 40 to 125 A b

E-16 Acti 9 | Catalogue 2014


Protection Accessories for C120, iSW,
Circuit protection C60H-DC devices (cont.)
Earth leakage protection

Connection
E
Accessories Multi-cable 50 mm² Al Screw-on Connection kit for ring Terminal for rear
terminal terminal connection for ring terminals connector
terminal
DB118780

DB118782

DB123897

058967N-23

DB118784
Function
For 3 copper cables: For 16 to 50 mm² For lug tipped cables, For terminal up to 63 A, front For cable up to 50 mm2 or by
b Rigid up to 16 mm² aluminium cables front or rear mounting or rear access terminal
b Flexible up to 10 mm² (screw Ø 5 mm) b Supplied with a 1P terminal
b It incorporates a "conductive" shield
part and an "insulating" part
DB118787

DB122935

DB118789

which ensures the phase-to-


phase clearance
5 mm

Cat. numbers 19091 19096 27060 27053 17400 18528


Set of 4 3 1 8 2 2
C120 b b b b – b
Vigi C120 b b b – – –
DPN, DPN Vigi – – – b – –
C60H-DC, b b b b b –
iSW 40 to 125 A
SW60-DC, b b b b – –
C60NA-DC
C60PV-DC – – b b – –
Tightening torque 2 N.m 10 N.m 2 N.m – –
Stripping length 11 mm 13 mm – – –
Tools to be used Diameter 5 mm or PZ2 Hc 1/5" or 5 mm Diameter 5 mm Diameter 5 mm –

Identification
Accessories Clip-on terminal marker strip
031204D_SE-23

Function For connection identification


Cat. numbers 0: AB1-R0 A: AB1-GA K: AB1-GK U: AB1-GU
1: AB1-R1 B: AB1-GB L: AB1-GL V: AB1-GV
2: AB1-R2 C: AB1-GC M: AB1-GM W: AB1-GW
3: AB1-R3 D: AB1-GD N: AB1-GN X: AB1-GX
4: AB1-R4 E: AB1-GE O: AB1-GO Y: AB1-GY
5: AB1-R5 F: AB1-GF P: AB1-GP Z: AB1-GZ
6: AB1-R6 G: AB1-GG Q: AB1-GQ +: AB1-R12
7: AB1-R7 H: AB1-GH R: AB1-GR -: AB1-R13
8: AB1-R8 I: AB1-GI S: AB1-GS Blank : AB1-RV
9: AB1-R9 J: AB1-GJ T: AB1-GT
Set of 250
C120 b 4 markers max. per pole
Vigi C120 b 4 markers max. per device
DPN, DPN Vigi b 4 markers max. per pole
C60H-DC, b 4 markers max. per pole
SW60-DC,
C60NA-DC,
C60PV-DC

Acti 9 | Catalogue 2014 E-17


Protection Acti 9 comb busbars
Acti 9 comb busbars
Circuit protection
Earth-leakage protection

Comb busbars
Acti 9 Not cuttable
PB110231-15

Function
Comb busbars make it easier to implement Schneider Electric products
b The phases are identified by symbols on each side of the comb busbar
b The spare teeth can be insulated with tooth covers
b They must not be cut
PB110290-40 + PB110793-40

Use
b Power supply by connector recommended

Number of poles 1P 2P 3P 4P 3 (N+P)


Type L1... L1L2... L1L2L3... NL1L2L3... NL1NL2NL3...
Catalogue 12 modules of 18 mm A9XPM112 A9XPM212 A9XPM312 A9XPM412 A9XPM512
numbers
Accessories – – – – –
Set of 1 1 1 1 1

Technical specifications
Rated voltage (Ue) 415 V
Insulation voltage (Ui) 500 V
Permissible current at 40°C 100 A
Short-circuit current withstand Compatible with the breaking capacity of Schneider Electric modular circuit breakers
Fire resistance to IEC 695-2-1 Self-extinguishing 960°C 30 s
Standards IEC 60947-7-1, IEC 61439-2
Colour RAL 7016 (anthracite grey)

E-18 Acti 9 | Catalogue 2014


Protection Acti 9 comb busbars (cont.)
Acti 9 comb busbars
Circuit protection
Earth-leakage protection

Accessories
Tooth covers Connectors
E
Monoconnect
PB110257-10

PB110259-15

b Insulate teeth that have been left free b Comb busbar power supply
PB108138-25 + PB108164-38

b Horizontal incomer on each side


b For 35 mm2 cable
b Tightening torque 4 N.m
– –

– –
A9XPT920 A9XPCM04
20 4

Acti 9 | Catalogue 2014 E-19


Protection Acti 9 comb busbars (cont.)
Acti 9 comb busbars
Circuit protection
Earth-leakage protection

Comb busbars
Acti 9 Cuttable
PB110243-14
PB110252-24

Function
Comb busbars make it easier to implement Schneider Electric products
b Can be sawn and cut in a single pass, using busbar chocks
b Supplied with two IP20 lateral end-pieces except for 57 module references
b The end-pieces are compulsory during cutting
b The phases are identified by symbols on each side of the comb busbar
b Cutting marks on the insulating material
b The spare teeth can be insulated with tooth covers
b The special comb busbars for circuit breakers with 9 mm auxiliaries have a 9 mm gap for inserting iOF and iSD

Strengths: the marking is clear, whether the supply comes from above or below
PB110290-40 + PB110793-40

Use
b Power supply by connector recommended

Number of poles 1P 2P 3P 4P 3 (N+P) Aux+1P Aux+2P Aux+3P Aux+4P


Type L1... L1L2... L1L2L3... NL1L2L3... NL1NL2NL3... AuxL1... AuxL1L2... AuxL1L2L3... AuxNL1L2L3 ...
Catalogue 6 modules of 18 mm A9XPH106 – – – – – – – –
numbers
12 modules of 18 mm A9XPH112 A9XPH212 A9XPH312 A9XPH412 A9XPH512 – – – –
18 modules of 18 mm – – – – A9XPH518 – – – –
24 modules of 18 mm A9XPH124 A9XPH224 A9XPH324 A9XPH424 A9XPH524 – – – –
57 modules of 18 mm A9XPH157 A9XPH257 A9XPH357 A9XPH457 A9XPH557 A9XAH157 A9XAH257 A9XAH357 A9XAH457
(end-pieces to be
ordered separately)
Accessories (optional) – – – – – – – – –
Set of 1 1 1 1 1 1 1 1 1

Technical specifications
Rated voltage (Ue) 415 V
Insulation voltage (Ui) 500 V
Permissible current at 40°C 100 A
Short-circuit current withstand Compatible with the breaking capacity of Schneider Electric modular circuit breakers
Fire resistance to IEC 695-2-1 Self-extinguishing 960°C 30 s
Standards IEC 60947-7-1, IEC 61439-2
Colour RAL 7016 (anthracite grey)

E-20 Acti 9 | Catalogue 2014


Protection Acti 9 comb busbars (cont.)
Acti 9 comb busbars
Circuit protection
Earth-leakage protection

Accessories
End-piece Tooth covers Connectors
E
Monoconnect

DB404806

DB404806

PB110259-15
b Lateral end-pieces providing IP20 protection b Insulate teeth that b Comb busbar power supply
have been left free

b Horizontal incomer
on each side
b For 35 mm2 cable
b Tightening torque 4 N.m
3 (Aux+1P) 3 (Aux+N+1P) 1P 2P 3P 4P – –
AuxL1AuxL2AuxL3... AuxNL1AuxNL2AuxNL3...
– – – – – – – –
– – – – – – – –
– – – – – – – –
– – – – – – – –
A9XAH657 A9XAH557 – – – – – –

– – A9XPE110 A9XPE210 A9XPE310 A9XPE410 A9XPT920 A9XPCM04


1 1 10 10 10 10 20 4

Acti 9 | Catalogue 2014 E-21


Install Distribloc 63 A splitter block

IEC/EN 60947-7-1.
IEC/EN 61439-2.

Description
PB104499-40

b Distribloc 63 A is a four pole splitter block installable on a standard DIN rail.


b Outgoing feeders are connected at the front, without screws, in spring terminals.
The contact pressure of the cable is independent of the operator.
b The spring contact pressure adapts automatically to the cross section of the
conductor. It is independent of the operator.

Advantages
b Very fast connection.
b Very simple phase rebalancing.
b In the event of an extension to or modification of the switchboard, connection is
very easy.
b The appearance of its front panel (45 mm front tip) enables it to fit in on a row
perfectly, alongside modular devices.
DB122626

Technical data
Main characteristics
Cat. no Distribution through the top 04040
Distribution through the bottom 04041
3.5 mm According to IEC/EN 60947-7-1
Degree of protection IP20
Rated insulation voltage (Ui) 500 V AC

12 mm Voltage rating (Ue) 440 V AC


Rated impulse withstand voltage (Uimp) 6 kV
Short-circuit current withstand Up to breaking capacity of
Schneider Electric outgoing circuit
breakers, even when reinforced by
cascading implementation
Reference temperature 40°C
Rated current at 40°C (In) 63 A
Operating frequency 50/60 Hz
Width in 9-mm modules 8
PB104500-60

Power supply 6.5 mm


b Four-pole tunnel terminals with screw clamping.
b The tunnel terminals are located to facilitate the PZ2
insertion of cables and clamping by screws. 14 mm 2 N.m
b A single cable per connection point:
v flexible from 4 to 16 mm²
v rigid from 6 to 25 mm².
Installation
b Clip-on mounting on
modular rail.
b Width occupied:
8x9-mm modules.

Distribution
b 3 outgoing feeders connected by flexible or rigid
cables of cross section 1 to 6 mm².
b 2 rows of terminals:
v 12 connection points for phases (L1, L2, L3)
v 12 connection points for neutral.
b A single cable per connection point: flexible (without
ferrule) or rigid from 1 to 6 mm².
b Reliable, maintenance-free (tightness guaranteed
over time).
b Insensitive to vibrations and thermal variations.

E-22 Acti 9 | Catalogue 2014


Install Distribloc 63 A splitter block
(cont.)

Additional characteristics
According to IEC/EN 60947-7-1 E
Rated cross section 16 mm²
Rated connecting capacity 10-16-25 mm²
Pollution degree 3
Storage temperature -40°C to +85°C
According to IEC/EN 61439-2
Operating temperature -25°C to +60°C
Colour RAL 7016, RAL 9003

Installation
DB122671

DB122625

Distribution through the bottom. Distribution through the top.

Weight (g)
Splitter block
Type
Distribloc 290

Dimensions (mm)
DB122616

Acti 9 | Catalogue 2014 E-23


Install Multiclip 80 A splitter block

IEC/EN 60947-7-1.
PB104507-35

IEC/EN 61439-2.

Description
b Multiclip 80 A is a four-pole splitter block 24 modules wide installable on a
standard DIN rail.
b Outgoing feeders are connected at the front, without screws, in spring terminals.
b The spring contact pressure adapts automatically to the cross section of the
conductor. It is independent of the operator.
b Supplied with 12 black and 12 blue pre-stripped 6 mm2 cables.
DB122626

Advantages
b Very fast connection.
b Very simple phase rebalancing.
b In the event of an extension to or modification of the switchboard, connection is
very easy.
b Compatible with inter-rows of 150 mm.
5.5 mm

Technical data
12 mm
Main characteristics
Cat. no 04000
According to IEC/EN 60947-7-1
Rated current at 40°C (In) 80 A
Maximum operated voltage (Ue) 440 V AC
Operating frequency 50/60 Hz
Rated insulation voltage (Ui) 500 V AC
Power supply Pollution degree 3
b Four-pole tunnel terminals with Rated impulse withstand voltage (Uimp) 6 kV
screw clamping. Degree of protection IP20
b The tunnel terminals are located Short-circuit current withstand Up to breaking capacity of
to facilitate the insertion of cables Schneider Electric outgoing circuit
and clamping by screws. breakers, even when reinforced by
b One cable per connection point: cascading implementation
v flexible from 6 to 25 mm² Width in 9-mm modules 48
v rigid from 10 to 35 mm².

6.5 mm
PZ2
14 mm 2 N.m
PB104501-45

Installation
b Clip-on mounted Pragma
and Prisma DIN rails.
b Screwed on all other
symetric rail.

Distribution
b Connection to spring terminals through the front.
b 2 rows of terminals:
v 18 connection points for phases (L1, L2, L3)
v 18 connection points for neutral.
b A single cable per connection point: flexible (without
ferrule) or rigid from 1 to 6 mm².
b Maintenance-free (tightness guaranteed over time).
Insensitive to vibrations and thermal variations.

E-24 Acti 9 | Catalogue 2014


Install Multiclip 80 A splitter block
(cont.)

E
PB104505-50

Additional characteristics
According to IEC/EN 61439-2
Operating temperature -25°C to +60°C
Storage temperature -40°C to +85°C
Colour RAL 7016

Installation
DB123198

On Pragma and Prisma rails


DB123199

On other symetric rails

Weight (g)
Splitter block
Type
Multiclip 640

Dimensions (mm)
415 42.5 42.5
DB123200

87.5

87.5
117

29.5

29.5

71 136.5 136.5 71 27 34

Acti 9 | Catalogue 2014 E-25


Protection Accessories for NG125 devices
Circuit protection
Earth leakage protection

Mounting
Accessories Rotary handle Toggle Padlocking device
DB123603

DB123604

DB123498

DB123605
Function
Extended rotary handle Direct rotary handle White toggle Allows padlocking:
b Degree of protection: rotary button b Front installation b Allows visual b In position I or O of NG125 1P or 2P
IP55 b Keeps disconnection distinction of a circuit breakers
b Front installation: b Padlocking possible when the switchboard incoming b In position I of NG125 3P or 4P
b Prevents door opening when the circuit device is in position O device circuit breakers or switches
breaker is in position O b Padlock diameter: 3 to 6 mm b Padlock: dia. 5 to 8 mm
b Keeps disconnection (not supplied)
b Padlocking possible when the device is
in position O Note: NG125 3P/4P circuit breakers
b Padlock diameter: 3 to 6 mm and switches are provided with
padlocking in position O
(disconnected) as original equipment.
b Two versions:
v standard black
v red handle and yellow front
plate for machine tool control
Catalogue 19088 19089 19092 19097 19099 19090
numbers Extended Extended safety Direct Direct safety White toggle
standard black standard red handle yellow
black background
Pack of 1 1 1 10 1
Suitable for the following devices:
NG125 b 3P, 4P b b 3P, 4P b
Vigi NG125 – – – –

Connection
Accessories Multi-cable terminal 70 mm2 Al terminal Screw-on connection for ring Small ring terminal
terminal
DB118780

DB123426

DB123427

DB123428

Function
For 3 copper cables: For aluminium cables from Installation: Connection ratings 80 to 125 A:
b Rigid up to 16 mm2 25 to 70 mm2 b Upstream or downstream b Flexible copper cable: 50 mm2
b Flexible up to 10 mm2 b Connection ratings 80 to 125 A: b Rigid copper cable: 70 mm2
v copper terminal:
- flexible cable up to 35 mm2
- rigid cable up to 50 mm2
v bars: 16 x 3 mm, 15 x 4 mm, 16 x 4 mm
v small ring terminal
b Phase-to-phase insulation voltage: Ui = 1000 V
DB118787

DB118789

DB123497
DB122935

6 mm
6 mm
l: 19 mm max.

Cat. nos. 19091 19096 19095 19093 19094


Pack of 4 3 4 4 4
NG125 b b b 80, 100, 125 A b 80, 100, 125 A b 80, 100, 125 A
Vigi NG125 – – b 125 A b 125 A b 125 A
Tightening torque 2 N.m 6 N.m 6 N.m 6 N.m
Stripping length 11 mm – – –
Tools to be used Diameter 5 mm or PZ2 Hc 4 mm Hc 4 mm –

E-26 Acti 9 | Catalogue 2014


Protection Accessories for NG125 devices
Circuit protection
Earth leakage protection (cont.)

Accessories
Safety
Screw shield Circuit breaker terminal RCD terminal shield
E
shield
DB123606

DB123607

DB123607
Function
b Prevents any contact with the b Prevents any contact with the b Installation: is mounted upstream of the circuit breaker and
connection screws terminals downstream of the Vigi device
b Protection against direct contact: b Installation: mounted upstream b Phase-to-phase insulation voltage Ui = 1000 V
v IP40: on front panel and downstream of circuit breaker b Protection against direct contact: IP40
v IP20: at the connection level b Phase-to-phase insulation voltage b Class II in steel or plastic enclosures (up to 440 V)
b Class II in steel or plastic Ui = 1000 V b Sealing possible (max. diameter: 1.2 mm)
enclosures b Protection against direct contact
b Sealing possible IP40
(max. diameter: 1.2 mm). b Class II in steel or plastic
enclosures (up to 440 V)
b Sealing possible
(max. diameter: 1.2 mm)
63 A 125 A
1P 2P 3P 4P 1P 2P 3P 4P 2P 3P 3P 4P 4P 3P 4P
adjustable adjustable

Catalogue 19084 19085 19086 19087 19080 19081 19082 19083 19074 19075 19077 19076 19078 19077 19078
numbers

Pack of 10 Set of 1 upstream / 1 downstream Set of 1 upstream / 1 downstream


Suitable for the following devices:
NG125 b b b b
Vigi NG125 – – b b

Acti 9 | Catalogue 2014 E-27


Protection Connection comb busbars
Circuit protection for C120 and NG125
Earth leakage protection

Comb busbars Accessories


Accessories 1P, 2P, 3P, 4P comb busbar Insulated connector

030921d
030920d

Function
The comb busbars make it easier to install Schneider Electric products. b Compatible with all Schneider Electric comb busbars
b Supplied with 2 side plates, IP 2 b Clip onto the comb busbar's insulating material, which
b Outgoing feeders can be marked gives them very great stability
b Cutting markings on the copper bars and the insulating material b Receive clip-on markers allowing circuit identification
b Self-extinguishing insulating material, colour RAL 7016
b The teeth left on standby can be isolated by tooth cover end-pieces

Wiring diagram

DB105976
DB105977

1 2

Use
Direct power supply on the circuit-breaker terminal: b For 25 mm2 semi-rigid cable
maximum 50 mm2 rigid

Catalogue numbers 14811 14812 14813 14814 14885


Number of 9 mm modules L = 430 mm, L = 430 mm, L = 405 mm, L = 430 mm, 16 poles of 27
16 poles of 16 poles of 15 poles of mm
27 mm 27 mm 27 mm
Set of 1 4

Suitable for the following devices:


C120 b b b b –
NG125 y 63 A b b b b –

Technical specifications
Voltage rating (Ue) 500 V
Acceptable current at 40°C 125 A
Max. current per feeder 63 A
Resistance to short-circuit Compatible with the breaking capacity of modular circuit breakers
currents

E-28 Acti 9 | Catalogue 2014


Functions and characteristics iDPN comb busbars

These comb busbars are a key part of the IEC 60947-7 concerning cable strength.
distribution system.
Combined with Schneider Electric distribution systems and
E
switchgear, comb busbars allow the construction of
switchboards tested in compliance with the IEC 60439-1
standard.
Comb busbars are available in several lengths for two types of distribution:
b single-phase 1P+N distribution
b three-phase 3P+N distribution (3P+N and 1P+N outgoing feeders can be
combined under the same comb busbar).
The comb busbars ensure:
b easy, reliable mounting of 1P+N and 3P+N, TL, CT, ID, V, BP and CM switchgear:
tooth positioning opposite the devices' terminals is ensured by indexing of copper
parts.

b C60/ID Group Feeder comb busbars contain two different parts:


v connection of Group Feeder switchgear: C60 (3P+N) or ID (3P+N) circuit breaker
in 18-mm modules, powered by cables, through the bottom, directly by the terminals,
v connection of Clario, Prodis and Librio switchgear in 9-mm modules.

b The special comb busbars for circuit breakers have a gap of 9 mm for inserting OF,
SD, OF+SD/OF auxiliaries.

Catalogue numbers
Standard comb busbars
DB123729

Complete comb busbars Number of 18-mm modules


(supplied with 4 side plates and Comb busbar Tooth cover
21501 1 tooth cover)
1P+N 12 3 21501
18 3 19512
24 6 21503
3P+N 12 3 21505
DB123730

18 3 19516
24 6 21507
21505 Comb busbars alone
1P+N 48 - 21089
3P+N 48 - 21093
C60/ID Group Feeder comb Number of Power supply
busbars alone 18-mm modules
DB101184-10

3P+N 12 Through left-side 10545


48 Through left-side 10546
48 Through right-side 10547
10545 Accessories
Set of 40 side plates 1P+N 21094
3P+N 21095
Set of 12 tooth covers (3 x 18-mm modules) 21096
DB123731

DB123732

DB123733

Set of 10 tooth cover end-pieces (1 x 18-mm module) 10405


21096 Set of 4 connectors (4 grey) 21098
21094
21098

Comb busbars for circuit breaker with 9-mm auxiliaries


PB110801-10

Comb busbars alone Number of 18-mm modules


Comb busbars 1P+N 56 A9N21035
A9N21036 3P+N 56 A9N21036
Comb busbars DPN Vigi 1P+N 56 A9N21037
3P+N 56 A9N21038
Accessories
PB110804-10

PB110805-10

PB110806-10

PB110807-10

Set of 20 side plates 1P+N A9N21039


3P+N A9N21040
Set of 10 phase connectors (grey) A9N21041
A9N21039 A9N21041 A9N21042 A9N21050 Set of 10 neutral connectors (blue) A9N21042
Set of 10 tooth cover (1 x 18-mm module) A9N21050

Acti 9 | Catalogue 2014 E-29


Functions and characteristics iDPN comb busbars (cont.)

Technical data
Main characteristics
According to IEC 60439-1 Peignes standards Peignes pour
auxiliaires
Insulation voltage (Ui) 440 V AC 500 V AC
Pollution degree 3 3
Rated impulse withstand voltage (Uimp) 6 kV 6 kV
Acceptable current at 40°C (Ie) 80 A 63 A
Voltage rating (Ue) Phase-to-neutral 230 V AC 230 V AC
Phase-to-phase 400 V AC 400 V AC
Additional characteristics
Degree of protection (IEC 60529) IP20
Fire resistance Self-extinguishability 960°C, 30 s/30 s
Dielectric strength (preserved after cutting) 2500 V AC
Colour RAL 7035 (the same color as device)
Resistance to short-circuit currents Compatible with the breaking capacity of the
circuit breakers in the range

Power supply
b Direct by Group Feeder earth leakage protection device.
b In the devices' terminals with comb busbar in place:
v 16 mm2 semi-rigid cable,
v 25 mm2 flexible cable.
b By insulated connector, horizontal inlet:
v 25 mm2 semi-rigid cable
v 16 mm2 flexible cable.

b Dismounting with comb


busbar in place

Marking
Tooth cover b Neutral and phase markings
b Isolates the comb busbar moulded in the insulating materialt
teeth not used b Marking area for self-adhesive
label or handwritten note

Cutting
b Cutting markings moulded in the
insulating material
b No dismounting of copper parts
before cutting
b 4 IPxxB side protection plates,
supplied

E-30 Acti 9 | Catalogue 2014


Protection Accessories and Auxiliaries
Circuit protection for iDPN
Earth leakage protection

Accessories and auxiliaries E


Mounting
accessories Comb busbars Padlocking Spacer Clip-on terminal markers

Comb busbars See page E-29


Padlocking 26970
9 mm spacer A9N27062
Clip-on terminal markers

Auxiliaries
Auxiliary contacts
Open/closed auxiliary contact OF.S for ID A9N26923
Open/closed auxiliary contact OF A9N26924 Auxiliary contacts Tripping devices Circuit Residual
Fault indicating switch SD A9N26927 breaker current device
Auxiliary contact OF/SD+OF A9N26929
(OF+SD or OF+OF combination)
Tripping devices
Undervoltage release MN or See page F-9
delayed undervoltage release
MNs or undervoltage release
with external power supply MNx
Shunt release MX, MX+OF or See page F-9
voltage threshold release MSU
OF.S ID

Acti 9 | Catalogue 2014 E-31


Supervision and
switchboard
control

E-32 Acti 9 | Catalogue 2014


Control, remote control, Acti 9 Smartlink
indication

IEC/EN 61131-2
The Acti 9 Smartlink transmits data from Acti 9 devices to a PLC or a supervision
E
system via the Modbus serial line communication network.
PB107797-47

Functions
Data transmission between the Modbus network and Acti 9 devices
b Circuit breakers, residual current circuit breakers, residual current devices:
v open/closed state
v tripped state
v number of opening/closing cycles
v number of tripping actions.
b Contactors, impulse relays:
v opening control
v closing control
v open/closed state
v number of cycles
v total period of operation of the load (device closed).
b Remote controlled circuit breaker/Reflex iC60:
v opening control
v closing control
v open/closed state
v tripped state
v number of cycles
v total period of operation of the load.
b Power meters:
v number of pulses recorded
v pulse value setting (e.g. kWh)
v total consumption recorded
v estimate of power consumption.

All the data are stored in memory: number of cycles, consumption, period of
operation, even in the event of a power failure.

The Acti 9 Smartlink can also exchange data with any device having 24 V DC digital
inputs/outputs.
No configuration of the connected products is required.

When the Acti 9 Smartlink is switched on, communication automatically adjusts to


the Modbus Master (PLC, control station) communication parameters.

Catalogue numbers
PB107753-68

Acti 9 Smartlink
Type Set of
A9XMSB11 Acti 9 Smartlink 1 A9XMSB11
Supplied with Modbus connector 1
24 V DC power supply connector 1
Locking clips for mounting on Multiclip 80 2
Accessories
Link USB / Modbus for Acti 9 Smartlink test 1 A9XCATM1
Prefabricated cables
With 2 connectors Short: 100 mm 6 A9XCAS06
PB107754-12

Medium-sized: 160 mm 6 A9XCAM06


Long: 870 mm 6 A9XCAL06

With 1 connector Long: 870 mm 6 A9XCAU06


PB107755-5
DB404941

iOF+SD24 24V
Connectors 5-pin connectors (Ti24) 12 A9XC2412
PB107756-7

SD
OF
0V
Mounting kit DIN rail (4 feet, 4 straps, 4 adapters) 1 A9XMFA04
Multiclip 200 A (4 adapters) 1 A9XM2B04
Spare parts Lock for Multiclip 80 A (2 clips) 1 A9XMLA02

Acti 9 | Catalogue 2014 E-33


Control, remote control, Acti 9 Smartlink (cont.)
indication

The Acti 9 communication system

PB107805-80
Acti 9 Smart Test software
b Electrical continuity test
b Functional testing of the devices
b Report printing
DB405140

b Printing of a simplified diagram


b Project archiving
b Compatible with Windows XP, Seven
b To be download on: Schneider Electric web sites:
v schneider-electric.com or
v schneider-electric country web site)

11 input/output channels
b Standard connectors
b In accordance with the IEC 61131-2
standard

Prefabricated cables
b Simplified cabling Modbus
b Communication adapts automatically to the
communication parameters of the Modbus b Fast and safe Communication
master (PLC, supervisor).
b Up to 32 slaves connected

Connectable devices
With Ti24 interface
Type Reference Description
iACT24 A9C15924 Low-level control and indication auxiliary for iCT contactors
PB107804-43

iATL24 A9C15424 Low-level control and indication auxiliary for iTL impulse relays
iOF+SD24 A9A26897 Low-level indication auxiliary for iC60, iID, ARA, RCA, iSW-NA
OF+SD24 A9N26899 Low-level indication auxiliary for C60, C120, DPN, RCCB/ID,
C60H-DC
RCA See page F-18 Remote control with Ti24 interface
Reflex iC60 See page G-3 Reflex iC60 with Ti24 interface
Without Ti24 interface
Power meters with pulse output, e.g. IEM2000T
Meters complying with the IEC 62053-21 standard
24 V DC indicator lamp, Harmony XVL range
All loads not exceeding 100 mA, 24 V DC
IC2000 light sensitive switches
Timers, thermostats, time switches, load shedding devices
All 24 V DC auxiliary contacts, IEC 61131-2 type 1

E-34 Acti 9 | Catalogue 2014


Control, remote control, Acti 9 Smartlink (cont.)
indication

Installation b Mounting in switchboards:


v width 24 modules per row;
v minimum spacing between rails 150 mm.
E

Ti24 connector
11 input/output channels
Protected at input against voltage Modbus connector
reversals b Pin 1: D1 Modbus
Protected at output by current limiting b Pin 2: D0 Modbus
b Pin 1: 0 V b Pin 3: shielding
b Pin 2: I1 Input 1 b Pin 4: common/0 V
b Pin 3: I2 Input 2 24 V DC power supply
b Pin 4: Q Output connector
b Pin 5: +24 V DC Protected against voltage
reversals
PB107762-175

b Indication of operation of the


communication system and the Thumbwheels
state of the Acti 9 Smartlink b Definition of the address
in the Modbus network

Acti 9 | Catalogue 2014 E-35


Control, remote control, Acti 9 Smartlink (cont.)
indication

Connection
Terminal Tightening Copper cables
DB123580

torque Rigid Flexible Flexible with ferrule

10 mm

DB122945

DB123553

DB123554
0.4 x 2,5 mm

Ti24 interface Spring loaded 0.5 to 1.5 mm2 0.5 to 1.5 mm2 -
terminal
Connector cat. no: A9XC2412
Power supply 0.8 N.m 0.2 to 1.5 mm2 0.2 to 1.5 mm2 0.2 to 1.5 mm2
DB124331

0V
connector
24 V

7 mm
3.5 mm

Modbus 0.8 N.m 0.25 mm2 0.25 mm2 0.25 mm2


DB405141

D0 = A’ / Rx-, A / Tx- connector


D1 = B’ / Rx+, B / Tx+
0V

3
7 mm

4 0.6 x 3,5 mm
DB405142

y 50 mm

1 y 20 mm
2

Weight (g)
Acti 9 Smartlink
Type
Acti 9 Smartlink 195

Dimensions (mm)
359 42
DB124330

22.5

E-36 Acti 9 | Catalogue 2014


Control, remote control, Acti 9 Smartlink (cont.)
indication

Technical characteristics
Characteristics of the Modbus link
E
Link Modbus, RTU, RS485 serial connection
Transmission Transfer rate 9600 baud ... 19200 baud, self-adaptable
Medium Shielded cable, double twisted pair
Structure Type Modbus.org
Method Master/Slave
Type of device Slave
Configuration Modbus addressing range Maximum number of slaves for a 99
of the Acti 9 Smartlink Modbus master
Maximum length of the bus 1000 m
Type of bus connector 4-pin connector
Power supply
Rated 24 V DC ± 20 %
Maximum input current 1.5 A
Maximum inrush current 3A
Meter
Capacity 232 pulses per input
Input characteristics
Type of input Current collector Type 1 IEC 61131-2
Number of channels 11 2-input channels
Maximum cable lengh 20 m
Rated voltage 24 V DC
Voltage limits 24 V DC ± 20 %
Rated current 2.5 mA
Maximum current 5 mA
Filtering time In state 1 1 ms
In state 0 1 ms
Isolation No isolation between ports
Negative sequence voltage protection Yes
Output characteristics
Number of output channels 11
Type of output 24 V DC 0.1 A current source
Rated voltage Voltage 24 V DC
Maximum current 100 mA
Filtering time In state 1 1 ms
In state 0 1 ms
Voltage drop (voltage in state 1) 1 V max
Maximum inrush current 500 mA
Leakage current 0.1 mA
Overvoltage protection 33 V DC
Environmental characteristics
Temperature Operating -25°C ... +60°C if vertical mounting, limited to 50°C
Storage -40°C…+80°C
Tropicalization Treatment 2 (relative humidity of 93% at 40°C)
Resistance to voltage dips 10 ms, class 3 as per IEC 61000-4-29
Degree of protection IP20
Pollution degree 3
Altitude Operating 0 … 2000 m
Vibration resistance As per IEC 60068.2.6 1 g / ± 3.5 mm - 5 Hz to 300 Hz - 10 cycles
Shock resistance As per IEC 60068.2.2 7 15 g / 11 ms
Immunity to electrostatic discharge As per IEC 61000-4-2 Air: 8 kV
Contact: 4 kV
Immunity to radiated magnetic fields As per IEC 61000-4-3 10 V/m - 80 MHz to 3 GHz
Immunity to fast transients As per IEC 61000-4-4 1 kV for inputs/outputs and Modbus communication.
2 kV for 24 DC power supply - 5 kHz - 100 kHz
Immunity to conducted magnetic fields As per IEC 61000-4-6 10 V from 150 kHz to 80 MHz
Immunity to magnetic fields at mains frequency As per IEC 61000-4-8 30 A/m
Resistance to corrosive atmospheres As per IEC 60721-3-3 Level 3C2 on H2S / SO2/ NO2 / Cl2
Fire resistance For live parts At 960°C 30 s / 30 s as per IEC 60 695-2-10 and IEC 60 695-2-11
For other parts At 650°C 30 s / 30 s as per IEC 60 695-2-10 and IEC 60 695-2-11
Salt spray test As per IEC 60068.2.52 Severity 2
Environment In compliance with the RoHS directive
Additional characteristics
Mean time between failure (MTBF) = MTTF at 70°C 1,851,818 h
Duration of saving memory 10 years
Prefabricated cables characteristics
Dielectric resistance 1 kV / 5 min
Minimum draw-out resistance 20 N

Acti 9 | Catalogue 2014 E-37


1 Acti 9 | Catalogue 2014
F

Monitoring
and control
of protections

Acti 9 | Catalogue 2014 F-1


Protection Electrical auxiliaries
Circuit protection
Earth leakage protection for iC60, iID, iDPN Vigi, iSW-NA,
RCA and ARA
b The electrical auxiliaries are combined with Tripping auxiliaries:
iC60 circuit breakers, iID residual current
IEC/EN 60947-1
circuit breakers, remote tripping switch b iMN: undervoltage release
disconnector iSW-NA , RCA remote controls b iMNs: delayed undervoltage release
and ARA automatic reclosers; they enable b iMNx: undervoltage release, independant from supply voltage
tripping or remote indication of their position b iMX: shunt release
(open/closed/tripped) upon a fault. b iMX+OF: shunt release with open/close contact.

b They are fastened by clips (without tools) to the


EN 50550
b iMSU: overvoltage release
left side of the breaker.
b The iOF/SD+OF auxiliary is a 2-in-1 product: via
Indication auxiliaries:
a mechanical selector switch, it provides two IEC/EN 60947-5-4
contacts, OF+SD or OF+OF. b iOF: open/close contact
b iSD: fault indicating contact
b The iOF+SD24 auxiliary can report open/closed b iOF/SD+OF: open/close contact and switchable OF or SD contact.
(OF) status information and intentional or fault b iOF+SD24: open/close contact OF and default indicating contact SD with Ti24
interface.
tripping of the associated device (SD) to the
Acti 9 Smartlink or a programmable logic
controller via the TI24 interface (24 V DC).
DB404939

F-2 Acti 9 | Catalogue 2014


Protection Electrical auxiliaries
Circuit protection
Earth leakage protection for iC60, iID, iDPN Vigi, iSW-NA,
RCA and ARA (cont.)
Combination table
Electrical auxiliaries Remote control Devices
Indication auxiliaries Tripping auxiliaries ARA automatic recloser iC60/iID/iDPN Vigi
or RCA remote control Vigi/iSW-NA*
Position

PB104440-25

PB104466-25
Left Right Max quantity
1 (iOF/SD+OF + 1 iOF/SD+OF + 1 (iMN, iMNs, iMNx or iMX, –
or iOF+SD24) iMX+OF)
Or 1 iOF + 1 (iSD or iOF or iOF/SD+OF) + 2 (iMN, iMNs, iMNx or iMX,
iMX+OF)
Or None + 1 iOF+SD24 + 2 (iMN, iMNs, iMNx or iMX,
iMX+OF)
Or None + None + 3 x iMSU iC60 Vigi iC60

PB104472-25
iID/iDPN Vigi/iSW-NA*
None + 1 (iSD or iOF or iOF/SD+OF or + 1 (iMN, iMNs, iMNx or iMX, F

PB104440-25

PB104466-25
PB106256-25

iOF+SD24) iMX+OF or iMSU)


Or 1 iOF + 1 (iSD or iOF or iOF/SD+OF) + None

iC60 Vigi iC60



PB104472-25

ARA iID
None + 1 (iSD or iOF or iOF/SD+OF or + 1 (iMN, iMNs, iMNx or iMX,
PB104466-25
PB106253-25

PB104440-25

iOF+SD24) iMX+OF or iMSU)


Or 1 iOF + 1 (iSD or iOF or iOF/SD+OF) + None

RCA iC60 Vigi iC60


Other possible associations: see technical pages

d
Tripping devices must be mounted first. Comply with the position of the SD function.
*iSW-NA : the iSD auxiliary contact must be associated with an auxiliary (iMN, iMX, iMX+OF); it indicates that the remote tripping
switch disconnector has been tripped open.

Acti 9 | Catalogue 2014 F-3


Protection Electrical auxiliaries
Circuit protection
Earth leakage protection for iC60, iID, iDPN Vigi, iSW-NA,
RCA and ARA (cont.)
Tripping
Auxiliaries iMN iMNs iMNx
Type Undervoltage release

Instantaneous Delayed Independent of the supply voltage


PB104477-35

PB104478-35

PB104480-35
Function
b Trips the device with which it is combined when its input voltage decreases b Tripping of the associated device by
(between 70 % and 35 % Un). Prevents device closing again until its input voltage is opening of the control circuit
restored (e.g. push-button, dry contact)

b Not tripping on transient voltage dip b A drop in the supply voltage does not
(up to 0.2 s) trip the associated device
b A locking push-button control allows
the circuit protected (e.g. machine
control) to be placed in safety
configuration
Wiring diagrams
DB118804

DB118805
U<

E1 E2 N/ L2
L1

Use
b Emergency stoppage by normally closed push button b Emergency stoppage with fail-safe
b Ensures the safety of power supply circuits for several machines by preventing principle
"uncontrolled" restarting b Insensitive to control circuit voltage
variation to increase service continuity
Important: Before any servicing
operation switch off the mains power
supply (voltage presence at terminals
E1/E2)
Catalogue numbers A9A26960 A9A26961 A9A26959 A9A26963 A9A26969 A9A26971
iC60, iID, iDPN Vigi, iSW-NA, RCA
b b b b b b
et ARA
iC60, iID double terminals b b b b b b

Technical specifications
Rated voltage V AC 220…240 48 115 220…240 220…240 380…415
(Ue) V DC – 48 – –
Standardised operating and – – – – – –
non-response to voltage times
(Ua)*
Maximum operating time – – – – – –
Minimum non-response time – – – – – –
Operating Hz 50/60 400 50/60 50/60
frequency
Red mechanical indicator On front face On front face On front face
Test function – – –
Width in 9 mm modules 2 2 2
Operating current – – –

Number of contacts – – –
Operating °C -35…+70 -35…+70 -35…+70
temperature
Storage °C -40…+85 -40…+85 -40…+85
temperature
*(Ua)
Voltages measured between the phase and the neutral conductor, at which the iMSU device must control the associated protective device.

F-4 Acti 9 | Catalogue 2014


Protection Electrical auxiliaries
Circuit protection
Earth leakage protection for iC60, iID, iDPN Vigi, iSW-NA,
RCA and ARA (cont.)

iMSU iMX iMX+OF


Overvoltage release Shunt release

With Open/Close auxiliary contact


PB104479-35

PB104496-35

PB104481-35
b Switches off the power supply by opening the breaker with b Trips the breaker when powered
which it is combined, in the event that the phase/neutral
voltage is exceeded (loss of neutral). For a four-phase
network, use three iMSU tripping auxiliaries
b Includes an open/close contact (OF) to indicate

F
the "open" or "closed" position of the breaker
DB118806

DB123012

DB118808

U> U>

14 12 C2 C1
11
(L/+) (N/-)

b Protection of equipment against overvoltages on the b Emergency stoppage by normally open push b Emergency stoppage by normally open push
electrical network button button
(neutral conductor break) b Remote indication of the position of the
b Voltage monitoring between phase and neutral conductors associated breaker

A9A26500 A9A26479 A9A26979 A9A26476 A9A26477 A9A26478 A9A26946 A9A26947 A9A26948

b b b b b b b

b b b b b b b

230 100…415 48 12…24 100…415 48 12…24


– 110…130 48 12…24 110…130 48 12…24
255 V AC 275 V AC 300 V AC 350 V AC 400 V AC – – – – – –

No tripping 15 s 5s 0.75 s 0.20 s – – – – – –


3s 1s 0.25 s 0.07 s – – – – – –
50/60 50/60 50/60

On front face On front face On front face


– – –
2 2 2
– – y 24 V DC 6A
48 V DC 2A
y 130 V DC 1A
y 240 V AC 6A
415 V AC 3A
– – 1 NO/NC
-35…+70 -35…+70 -35…+70

-40…+85 -40…+85 -40…+85

Acti 9 | Catalogue 2014 F-5


Protection Electrical auxiliaries
Circuit protection
Earth leakage protection for iC60, iID, iDPN Vigi, iSW-NA,
RCA and ARA (cont.)
Indication
Auxiliaries iOF iSD iOF/SD+OF iOF+SD24
Type Open/close Fault indicating contact Double open/close or fault Double open/close and
auxiliary contact indicating contact fault indicating contact

PB107750-35
PB104474-35

PB104476-35

PB104475-35
Function
b Changeover contact b Changeover contact b The iOF/SD+OF auxiliary is a b Double changeover
indicates "open" or "closed" indicates position of the 2-in-1 product: via a mechanical contact which can report the
position of the breaker breaker; upon: selector switch, it provides two signalling information of the
v electrical fault contacts, OF+SD or OF+OF associated device to the Acti
v action on tripping auxiliary 9 Smartlink or a
b Same indication as programmable logic
VISI-TRIP controller:
v electrical fault
v actuation of the tripping
auxiliary
v "Open" or "Closed"
position of the associated
device

Wiring diagrams
DB118810

DB118811

DB118812

DB118813

DB124318

OF position SD position
Use
b Remote indication of b Remote indication of b Remote indication of position b Remote indication of
the position of the associated tripping upon a fault of the and/or tripping upon a fault of the position and tripping upon a
breaker associated breaker associated breaker fault of the associated
breaker
Catalogue numbers A9A26924 A9A26869 A9A26927 A9A26855 A9A26929 A9A26997
iC60, iID, iDPN Vigi, iSW-NA,
b – b – b b
RCA et ARA
iC60, iID double terminals – b – b b b

Technical specifications
Rated voltage (Ue) V AC 240…415 240…415 240…415 -
V DC 24…130 24…130 24…130 24
Operating Hz 50/60 50/60 50/60 -
frequency
Red mechanical indicator – On front face On front face On front face
Test function On toggle On toggle On toggle On toggle
Width in 9 mm modules 1 1 1 1
Operating current 24 V DC 6A 2 mA mini, 50 mA maxi
48 V DC 2A -
60 V DC 1.5 A -
130 V DC 1A -
240 V AC 6A -
415 V AC 3A -
Number of contacts 1 NO/NC 1 NO/NC 1 NO/NC + 1 NO/NC 1 NO/NC
Operating °C -35…+70 -35…+70 -35…+70 -25…+70
temperature
Storage °C -40…+85 -40…+85 -40…+85 -40…+85
temperature

F-6 Acti 9 | Catalogue 2014


Protection Electrical auxiliaries
Circuit protection
Earth leakage protection for iC60, iID, iDPN Vigi, iSW-NA,
RCA and ARA (cont.)
Connection
Type Tightening Copper cables Multi-cables terminal
DB123061

torque Rigid Flexible Rigid cables Cables with


ferrule
4 mm

DB122945

DB123007

DB123008
DB123011
PZ1
10 mm

Indication auxiliaries 1 N.m 1 to 4 mm2 0.5 to 2.5 mm2 2 x 2.5 mm2 2 x 1.5 mm2
Tripping auxiliaries 1 N.m 1 to 6 mm2 0.5 to 4 mm2 2 x 2.5 mm2 2 x 2.5 mm2

Ti24 connector connection


Type Catalogue Copper cables
DB123580

Spring-loaded
terminals numbers Rigid Flexible

F
DB122945

DB123553
10 mm
0.4 x 2.5 mm

Ti24 interface A9XC2412 2 x 1.5 mm2 2 x 1.5 mm2

Ti24 prefabricated cables connection


Type Catalogue numbers Length
Connection for Acti 9 Smartlink
6 short prefabricated A9XCAS06 100 mm
PB107754-10

6 medium-sized prefabricated A9XCAM06 160 mm


6 long prefabricated A9XCAL06 870 mm

Connection for PLC type terminals


6 long prefabricated on a A9XCAU06 870 mm
PB107755-14

single side
DB404941

iOF+SD24 24V

SD
OF
0V

Acti 9 | Catalogue 2014 F-7


Protection Electrical auxiliaries
Circuit protection
Earth leakage protection for iC60, iID, iDPN Vigi, iSW-NA,
RCA and ARA (cont.)
Technical data
Weight (g)
Electrical auxiliaries
Type
iMN 69
iMNs 72
iMNx 79
iMSU 68
iMX 64
iMX+OF 68
iOF 32
iSD 33
iOF/SD+OF 43
iOF+SD24 25

Dimensions (mm)
67.5 67.5 68 67.5
DB124223

63.5 63.5 66 63.5


9 44 44 44 49.5
9 9 17.5
5.5
5.5 5.5 5.5

90 45 86 45 88 45 85 86 45

iOF/SD+OF iOF, iSD iOF+SD24 iMN, iMNs, iMNx, iMSU, iMX, iMX+OF

F-8 Acti 9 | Catalogue 2014


Protection Electrical auxiliaries for C120, ID,
Circuit protection C60H-DC devices
Earth leakage protection

b The electrical auxiliaries provide the remote Tripping auxiliaries:


tripping or position (open/closed/tripped)
indication functions of these devices in the IEC/EN 60947-1
b MN: undervoltage release
event of a fault. b MNs: delayed undervoltage release
b They clip on (no tool required) to the left-hand b MNx: undervoltage release, independent of the supply voltage
b MX: shunt release
side of the associated device.
b MX+OF: shunt release with open/closed contact.
b The OF+SD/OF auxiliary is a two-in-one EN 50550
product: a mechanical selector switch is used to b MSU: overvoltage release
select one of two contacts: OF+SD or OF+OF.
b The OF+SD24 auxiliary can report open/closed
Indication auxiliaries:
(OF) status information and intentional or fault IEC/EN 60947-5-4
tripping of the associated device (SD) to the b OF.S: open/closed contact for ID
Acti 9 Smartlink or a programmable logic b OF: open/closed contact
controller via the TI24 interface (24 V DC). b SD: fault indicating contact
b OF+SD/OF: choice of open/closed contact and OF or SD contact
d via the selector switch
b OF/SD+OF: open/close contact and switchable OF or SD contact.
b The electrical auxiliaries are not compatible with
ID residual current circuit breakers of type B. b OF+SD24: pen/close contact OF and cfault indicating contact SD with Ti24
interface.
DB124453

d
Tripping devices must be installed first.
If two tripping devices are used: the MN undervoltage
release must be installed first
Indication auxiliaries: install the SD auxiliary first (1) MSU is not used in direct current

Acti 9 | Catalogue 2014 F-9


Protection Electrical auxiliaries for C120, ID,
Circuit protection C60H-DC devices (cont.)
Earth leakage protection

Tripping
Auxiliaries MN MNs MNx
Type Undervoltage release

Instantaneous Delayed Independent of the supply voltage


PB107151-30

PB107152-30

PB107149-30
Function
b Causes the device with which it is associated to trip when its input voltage b Tripping of the associated device by opening
decreases of the control circuit
(between 70 % and 35 % of Un). Prevents the device from closing until its input (e.g. push-button, dry contact)
voltage has been restored
b No tripping in the event of b A drop in the supply voltage does not trip the
transient voltage dips (up to 0.2 s) associated device
b A locking push-button control allows the
circuit protected (e.g. machine control) to be
placed in safety configuration

Wiring diagrams
DB118804

DB118805
U<

E1 E2 N/ L2
L1

Utilization
b Emergency stop via a normally-closed pushbutton b Fail-safe emergency stop
b Ensures the safety of the power supply circuits of several machines by b Insensitive to the variation in the control circuit
preventing accidental startups voltage to improve continuity of service
Important: Before any servicing operation
switch off the mains power supply (voltage
presence at terminals E1/E2)
Catalogue numbers A9N26960 A9N26961 A9N26959 A9N26963 A9N26969 A9N26971
C120, DPN, DPN Vigi, ID b b b b b b
C60H-DC, SW60-DC, b b b b b b
C60PV-DC, C60NA-DC

Technical specifications
Rated voltage V AC 220…240 48 115 220…240 230 400
(Ue) V DC – 48 – – –
Standardised operating and – – – – – –
non-response to voltage times
(Ua)*
Maximum operating time – – – – – –
Minimum non-response time – – – – – –
Operating Hz 50/60 400 50/60 50/60
frequency
Mechanical state indicator light, On front face On front face On front face
red
Test function – – –
Width in 9 mm modules 2 2 2
Operating current – – –

Number of contacts – – –
Operating °C -25…+50 -25…+50 -25…+50
temperature
Storage °C -40…+85 -40…+85 -40…+85
temperature
Standards
IEC/EN 60947-1 b b b
IEC/EN 60947-5-1 – – –
EN 60947-2 b b –
EN 62019-2(1) – – –
(1) For C120, DPN.
*(Ua)
Voltages measured between the phase and the neutral conductor, at which the MSU device must control the associated protective device.

F-10 Acti 9 | Catalogue 2014


Protection Electrical auxiliaries for C120, ID,
Circuit protection C60H-DC devices (cont.)
Earth leakage protection

MSU MX MX+OF
Voltage threshold release Shunt release

With Open/Close auxiliary contact


PB107153-30

PB107150-30

PB107148-30
b Cuts off the power supply by opening the device with b Trips the associated device when it is powered on
which it is associated when the phase/neutral voltage is
exceeded (loss of neutral). For a four-phase network, use
three MSU tripping auxiliaries
b Includes an open/close contact (OF) to indicate
the "open" or "closed" position of the breaker

F
DB123012

DB118808
DB118806

U> U>

14 12 C2 C1
11
(L/+) (N/-)

b Protection of the devices against overvoltages on the b Emergency stop via a normally-open b Emergency stop via a normally-open
electrical network (break in the neutral conductor) pushbutton. pushbutton
b Monitoring the voltage between the phase conductor and b Remote indication of the position of the
the neutral conductor associated device

A9N26500 A9N26476 A9N26477 A9N26478 A9N26946 A9N26947 A9N26948


b b b b b b b
– b b b b b b

230 100…415 48 12…24 100…415 48 12…24


– 110…130 48 12…24 110…130 48 12…24
255 V AC 275 V AC 300 V AC 350 V AC 400 V AC – – – – – –

No tripping 15 s 5s 0.75 s 0.20 s – – – – – –


3s 1s 0.25 s 0.07 s – – – – – –
50/60 50/60 50/60

On front face On front face On front face

– – –
2 2 2
– – 3 A / 415 V AC
6 A / y 240 V AC
– – 1 NO/NC
-25…+50 -25…+50 -25…+50

-40…+85 -40…+85 -40…+85

b b b
– – –
– – –
– – –

Acti 9 | Catalogue 2014 F-11


Protection Electrical auxiliaries for C120, ID,
Circuit protection C60H-DC devices (cont.)
Earth leakage protection

Indication
Auxiliaries OF.S OF SD OF+SD/OF OF+SD24
Type Open/closed Open/closed Fault indicating Double open/closed or fault Double open/close
auxiliary contact auxiliary contact contact indicating contact and fault indicating
contact
PB100628_SE-28-b

PB107145-30

PB107146-30

PB100625_SE-28-b

PB107760-35
Function
b Changeover b Changeover b Changeover b The OF+SD/OF auxiliary is a b Double changeover
contact indicating the contact indicating the contact indicating the two-in-one product: choice of OF + SD contact which can report
"open" or "closed" "open" or "closed" position of the or OF + OF contact via the selector the signalling information of
position of the position of the associated device in switch the associated device to the
the event of:
associated device associated device v electrical fault Acti 9 Smartlink or a
v action on the programmable logic
tripping auxiliary controller:
v electrical fault
d Not compatible v actuation of the tripping
with a ID residual auxiliary
current circuit v "Open" or "Closed"
breaker, use an position of the associated
OF+SD/OF in the SD device
position
Wiring diagrams

DB124318
DB118809

DB118810

DB118811

DB118812

DB118813

14 12 11

OF position SD position
Utilization
b Remote indication b Remote indication b Remote fault b Remote position and/or fault b Remote indication of
of the position of the of the position of the tripping indication of tripping indication of the associated position and tripping upon a
associated device associated device the associated device device fault of the associated
breaker
Catalogue numbers A9N26923 A9N26924 A9N26927 A9N26929 A9N26899
ID b b b b b
C120, DPN, DPN Vigi, – b b b b
C60H-DC, C60H-DC,
SW60-DC, C60PV-DC,
C60NA-DC

Technical specifications
Rated voltage V AC 24…415 24…415 24…415 24…415 –
(Ue) V DC 24…130 24…130 24…130 24…130 24
Operating Hz 50/60 50/60 50/60 50/60 –
frequency
Mechanical state indicator – – On front face On front face On front face
Test function – On front face On front face On front face On toggle
Width in 9 mm modules 1 1 1 1 1
Operating current 3 A /415 V AC 2 mA mini, 50 mA maxi
6 A / y 240 V AC
Number of contacts 1 NO/NC 1 NO/NC 1 NO/NC 1 NO/NC + 1 NO/NC 1 NO + 1 NC
Operating °C -25…+50 -25…+50 -25…+50 -25…+50 -25…+70
temperature
Storage °C -40…+85 -40…+85 -40…+85 -40…+85 -40…+85
temperature
Standards
IEC/EN 60947-1 – – – – –
IEC/EN 60947-5-1 b b b b b IEC 60947-5-4
EN 60947-2 – – – – –
EN 62019-2(1) b b b b –
(1) For C120, DPN.

F-12 Acti 9 | Catalogue 2014


Protection Electrical auxiliaries for C120, ID,
Circuit protection C60H-DC devices (cont.)
Earth leakage protection

Connection
Type Tightening Copper cables
DB1261475

torque Rigid Flexible or with ferrule


4 mm

DB122945

DB122946
PZ1

Indication and tripping 1 N.m 0.5 to 2.5 mm² 2 x 1.5 mm2


auxiliaries
9 mm

Ti24 connector connection


Type Catalogue Copper cables
DB123580

Spring-loaded
terminals numbers Rigid Flexible

DB122945

DB123553
10 mm
0.4 x 2.5 mm

Ti24 interface A9XC2412 1 x 0.5 to 1.5 mm2 1 x 0.5 to 1.5 mm2


F
Ti24 prefabricated cables connection
Type Catalogue numbers Length
Connection for Acti 9 Smartlink
6 short prefabricated A9XCAS06 100 mm
PB107754-10

6 medium-sized prefabricated A9XCAM06 160 mm


6 long prefabricated A9XCAL06 870 mm

Connection for PLC type terminals


6 long prefabricated on a A9XCAU06 870 mm
PB107755-14

single side
DB404941

iOF+SD24 24V

SD
OF
0V

Acti 9 | Catalogue 2014 F-13


Protection Electrical auxiliaries for NG125
Circuit protection
devices

b The electrical auxiliaries are combined with IEC/EN 60947-2


NG125 circuit breakers and NG125 switch-
disconnectors; they provide the remote tripping b Tripping auxiliaries:
or position (open/closed/tripped) indication v MN: undervoltage release
functions of these devices in the event of a fault. v MNx: undervoltage release, independent of the supply voltage
b They clip on (no tool required) to the left-hand v MX+OF: shunt release with open/closed contact
v MXV: shunt release for Vigi add-on residual current device.
side of the associated device.

IEC/EN 60947-5-1
b Indication contacts:
v OF+OF: open/closed contact
v OF+SD: fault indicating contact
v MX+OF: shunt release with open/closed contact
v SDV: fault indicating contact for Vigi add-on residual current device.
DB123424

Combination table
Electrical auxiliaries Device
Indication auxiliaries Tripping auxiliaries
Max. quantity
056902N_SE-28

2 (OF+OF or OF+SD) + + 1 (MX+OF or MN or MNx)

NG125

Connection
Type Tightening Copper cables Multi-cable terminal
DB123413

torque Rigid Flexible or Flexible or Cables with


with ferrule rigid cables ferrule
5 mm
DB122945

DB123411

DB123412
DB123011

PZ1

10 mm
Indication 1 N.m 0.5 to 2.5 mm2 0.5 to 1.5 mm2 2 x 2.5 mm2 2 x 1.5 mm2
contacts
Tripping auxiliaries 1 N.m 0.5 to 2.5 mm2 0.5 to 1.5 mm2 2 x 2.5 mm2 2 x 1.5 mm2

F-14 Acti 9 | Catalogue 2014


Protection Electrical auxiliaries for NG125
Circuit protection
devices and for Vigi NG125 add-on
residual current devices (cont.)
Tripping
Auxiliaries MN MNx MX+OF
Type Undervoltage release Shunt release

Instantaneous Independent of the supply voltage With open/closed auxiliary contact


056367_SE-28

057084N_SE-28

056368_SE-35
Function
b Causes tripping of the device with b Tripping of the associated device by b Causes tripping of the associated device when
which it is combined when its input voltage opening of the control circuit powered
decreases (between 70% and 35% of Un). (e.g. push-button, dry contact)
Prevents closing of the device until its
input voltage has been restored
b A drop in the supply voltage does b Includes an open/closed contact (OF) to indicate
not trip the associated device the "open" or "closed" position of the associated

F
b A locking push-button control allows device
the circuit protected (e.g. machine
control) to be placed in safety
configuration
Wiring diagrams
DB123415

DB123416

DB123417

U< U< U>

D1 D2 E1 E2 N/ L2 14 12 C2 C1
L1

Utilization
b Emergency stop by normally-closed b Fail-safe emergency stop b Provided with a self-interrupting contact
pushbutton b Insensitive to variations in the
b Ensures safety of the power supply control circuit voltage for improved
circuits for several machines by continuity of service
preventing untimely restarting Important: Before any servicing
operation switch off the mains
power supply (voltage presence at
terminals E1/E2)
Catalogue numbers 19067 19069 19070 19061 19064 19065 19066 19063

Technical specifications
Rated voltage (Ue) V AC 230…240 48 – 220…240 230…415 48…130 24 12
V DC – – 48 – 110…130 48 24 12
Operating Hz 50/60 50/60 50/60
frequency
Mechanical state indicator On front face On front face On front face
light, red
Width in 9 mm modules 2 4 2
Current rating – – u 240 V AC 3A
< 240 V AC 6A
130 V CC 1A
y 48 V CC 2A
y 24 V CC 6A
Number of contacts – – –
Operating °C -25…+60 -25…+60 -25…+60
temperature
Storage °C -40…+85 -40…+85 -40…+85
temperature

Acti 9 | Catalogue 2014 F-15


Protection Electrical auxiliaries for NG125
Circuit protection
devices and for Vigi NG125 add-on
residual current devices (cont.)
Signalisation
OF+OF OF+SD
Auxiliary contact Fault indicating contact

056368_SE-28

b Double changeover contact indicating "open" or "closed" b Double changeover contact indicating:
position of the associated device v the position of the associated device in the event of:
- electrical fault
- actuation of the tripping auxiliary
v the "open" or "closed" position of the associated device

12 11 14 11 12 14
DB123419

OF
SD

21 22 24 95 98 96

b Remote indication of the position of the associated device b Remote indication of tripping upon a fault of the associated device

19071 19072

220…240 220…240
– –
50/60 50/60

– –

1 1
240 V AC 6A 240 V AC 6A
415 V AC 3A 415 V AC 3A

2 NO/NC 2 NO/NC
-25…+60 -25…+60

-40…+85 -40…+85

F-16 Acti 9 | Catalogue 2014


Protection Electrical auxiliaries for NG125
Circuit protection
devices and for Vigi NG125 add-on
residual current devices (cont.)
Indication
Auxiliaries MXV SDV
Type Shunt release Vigi fault indicating contact
054647_90250E_SE-35

054648_90250E_SE-35
Function
b At power up, actuates tripping of a circuit breaker b Normally-closed or normally-open contact indicating tripping upon an
or residual current circuit breaker earth fault (including tripped by MXV)
b It is provided with a self-interrupting contact
Wiring diagrams

DB123414
DB123423
DB123422

U>

M1 M2 11 12 13 14 F
Utilization
b Adaptable to 125 A Vigi add-on residual current device, all types, and to 63 A Vigi add-on residual current device, adjustable
b Impulse withstand voltage: 6 kV
b High-impedance input: use an iACTp if the
leakage current in the control unit exceeds 1 mA
(e.g. illuminated pushbutton)
Catalogue numbers 19060 19058 19059
Suitable for the following devices:
NG125 – –
Vigi NG125 b b

Technical specifications
Rated voltage (Ue) V AC 110…240 250
V DC 110 –
Operating Hz 50/60 50/60
frequency
Number of contacts – 1 NO 1 NC
Current rating – 0.1 to 1 A (AC14)
Operating °C -25…+60 -25…+60
temperature
Storage °C -40…+85 -40…+85
temperature

Acti 9 | Catalogue 2014 F-17


Control RCA remote controls
Remote control For iC60 circuit breakers
DB123576

b Lead sealing of b Locking device capable of neutralizing


operating modes remote control and padlocking (Ø 3 to 6 mm)
in open position

b Ti24 interface for link to


PLC and Acti 9 Smartlink

b Operating state
indicator lamp

b Compatible with
the circuit breaker's
electrical auxiliaries b Selector
switch for
inhibition of all
electrical
controls

b Bistable operation: does not change


b Operating state b Latched order or state in the event of electrical power
indicator lamp impulse-type control outage
DB123763

Legend
Type Application
+24VDC V DC power supply
Y3 Latched order centralized control
SD Circuit-breaker tripping information
OF Control circuit state information (open/closed)
0V V DC power supply
DB123578

DB123579

Y1 Latched order local control


Y2 Impulse-type or latched order local control (depending on mode)
N 230 V AC, 50 Hz power supply
P
OF Circuit-breaker state indication contact (open/closed)
11 12 14

Indication auxiliaries Tripping RCA remote iC60 circuit Vigi iC60


auxiliaries control breaker add-on RCD
PB104474-25

PB104475-25

PB104496-25

+ + + + +
No 1 (iSD or iOF or iOF/SD+OF 1 (iMX or iMN) max.
PB106253-25

PB104437-25

PB104437-25

or iOF+SD24)
1 iOF 1 (iSD or iOF or iOF/SD+OF) No

RCA iC60 Vigi iC60

F-18 Acti 9 | Catalogue 2014


Control RCA remote controls (cont.)
Remote control For iC60 circuit breakers

The RCA remote control system allows:


PB106253-40

b Remote electrical control (opening and closing) of circuit breakers with or without
Vigi add-on RCD, with or without auxiliary.
b Circuit-breaker resetting after tripping, in accordance with safety principles and
the regulations in force.
b Local control by operating handle.
b Circuit placing in safety configuration by padlocking.

2 choices of operation after tripping:


b A: Enabling of remote circuit-breaker resetting;
b B: Inhibition of remote resetting.

The version with Ti24 interface allows:


b Direct interfacing of remote control with a programmable logic controller (PLC),
PB106251-40

a supervision system and any other communication device, having inputs/outputs


in 24 V DC (control, OF and SD indications).
b Fast, reliable connection of the remote control to the Acti 9 Smartlink thanks to the
prefabricated cables.
b Remote indication by "OF" potential-free contact.
b Provision of 2 operating modes, "1 and 3".

The iMDU auxiliary allows RCA control in 24/48 V AC/DC.

Catalogue numbers F
RCA remote control
Type Width in 9 mm
modules
For circuit breakers Voltage
1P, 1P+N, 2P
Without Ti24 interface 230 V AC, 50 Hz A9C70112 7
With Ti24 interface 230 V AC, 50 Hz A9C70122 7
For 3P, 4P circuit breakers
Without Ti24 interface 230 V AC, 50 Hz A9C70114 7
With Ti24 interface 230 V AC, 50 Hz A9C70124 7
Auxiliaries See page E-10 and F-2
DB123572
DB123813

Legend
Type Application
OFF All remote control inhibited
auto A Circuit breaker remote reclosing after tripping allowed
B Circuit breaker remote reclosing after tripping inhibited
Green indicator lamp Remote control possible
Orange indicator lamp Remote control impossible
1 (Ti24) Mode 1
Without Ti24 interface 3 (Ti24) Mode 3
Y1 Latched order local control
DB123573

Y2 Impulse-type or latched order local control (depending on mode)


Y3 Latched order centralized control

With Ti24 interface

Acti 9 | Catalogue 2014 F-19


Control RCA remote controls (cont.)
Remote control For iC60 circuit breakers

Standard RCA RCA Ti24


b The orders received on terminals Y1 and Y2 are
taken into account progressively in their order of arrival.

DB123743
DB123396

Centralized
control
(PLC)
24 V DC
iC60 Y3 Y3
RCA Ti24 Ti24
RCA RCA
OF OF

N P Y2 Y1
Y1/Y2 Y1/Y2
230 V 230 V
Zone 1 Zone 2

Local control Local control

RCA Ti24 mode 1


DB123761

Mode 1: Locally or centrally controlled


230 V AC
circuit-breaker opening/closing
0V
b The orders come from various control points, and they are OF
taken into account in their order of arrival SD
b Y1: Latched order local control Y3
b Y2: Impulse-type local control 24 V c
b Y3: Latched order centralized control
Ti24
RCA

OF

N P Y2 Y1 11 12 14

RCA Ti24 mode 3


DB123762

Mode 3: Centrally controlled


opening/closing + local override 230 V AC
0V
b 3 positions allowing a choice between override and OF
centralized control: SD
b Y1: Latched order local control Y3
b Y2: Latched order local control 24 V c
b Y3: Latched order centralized control
Ti24
RCA

OF

N P Y2 Y1 11 12 14

Y2 Y1
OFF

ON Centralized
control (Y3)

F-20 Acti 9 | Catalogue 2014


Control RCA remote controls (cont.)
Remote control For iC60 circuit breakers

Connection Without accessories


Terminal Tightening Copper cables
DB123565

torque Rigid Flexible Flexible with ferrule

DB122945

DB123553

DB123554
3.5 mm
PZ1
10 mm Power supply (N/P) 1 N.m 0.5 to 10 mm2 0.5 to 6 mm2 0.5 to 4 mm2
Inputs (Y1/Y2) 2 x 0.5 to 2 x 2.5 mm2 2 x 0.5 to 2 x 2.5 mm2 2 x 0.5 to 2 x 2.5 mm2

Outputs (OF) 0.7 N.m 0.5 to 2.5 mm2 0.5 to 2.5 mm2 0.5 to 1.5 mm2
DB123568

2 x 0.5 to 2 x 1.5 mm2 2 x 0.5 to 2 x 1.5 mm2 2 x 0.5 to 2 x 1.5 mm2

8 mm
3.5 mm

Ti24 interface Spring-loaded 0.5 to 1.5 mm2 0.5 to 1.5 mm2 -


F
DB123764

terminals
10 mm
3.5 mm

Technical data
DB123310

Control circuit
Supply voltage (Ue) (N/P) 230 V AC, 50 Hz
Control voltage (Uc) Type 1 inputs (Y1/Y2) 230 V AC (as per IEC 61131-2)
Min. duration of control order (Y2) u 200 ms
Response time (Y2) < 500 ms
Consumption y1W
Thermal self-protection with automatic Reset against overheating of the control circuit due to an
Clip on DIN rail 35 mm. abnormal number of operations
Endurance (O-C) (RCA combined with a circuit breaker)
Electrical/Mechanical 10,000 cycles
DB123312

Indication / Remote control


Potential free changeover Min. 24 V AC/DC, 10 mA
contact output (OF) Max. 230 V AC ,1 A
Input (Y1/Y2) 230 V AC 5 mA
Ti24 interface (as per IEC 61131)
Type 1 input (Y3) 24 V DC 5.5 mA
Indifferent position of installation. Output (OF and SD) 24 V DC In max.: 100 mA
Additional characteristics
Degree of protection Device only IP20
(IEC 60529)
IP20 IP40 Device in a modular IP40
DB123314

enclosure Insulation class II


Insulation voltage (Ui) 400 V
Degree of pollution (IEC 60947) 3
Rated impulse withstand voltage (Uimp) 6 kV
Operating temperature -25°C to +60°C
Storage temperature -40°C to +70°C
Tropicalization Treatment 2
(relative humidity of 93 % at +40°C)

Acti 9 | Catalogue 2014 F-21


Control RCA remote controls (cont.)
Remote control For iC60 circuit breakers

Weight (g)
Remote controls
Type RCA
For 1P, 1P+N, 2P circuit breakers 400
For 3P, 3P+N, 4P circuit breakers 430

Dimensions (mm)
135
DB123567

4P
3P 117
2P (1P+N) 99
1P 81 70
63 3 5.5 44.5
2

85 45

6
80
97

F-22 Acti 9 | Catalogue 2014


Control ARA automatic reclosers (cont.)
Remote control For iC60 circuit breakers
and iID residual current circuit breakers

b Sealable cover
PB106050-78

b Indication of ARA
operating states b Placing in safety configuration by
integrated padlocking device (Ø 3 to 6 mm)

b 4 predefined
programs

b Manual control of the


circuit breaker or residual

F
current circuit breaker
always overrides automatic
control

b Bistable operation: does not


b Manual remote control of change state in the event of
final reclosing (after inhibition electrical power outage
of automatic recloser) (Y2)
b Remote inhibition of remote
reclosing (Y1) b Inhibition of automatic
recloser (auto - OFF) and
resetting (Reset)

Indication auxiliaries Tripping ARA remote iC60 or iID Vigi iC60


auxiliaries control device add-on RCD
PB104474-25

PB104475-25

PB104496-25

+ + + + +
No 1 (iSD or iOF or iOF/SD+OF 1 (iMX or iMN) max.
PB106256-25

PB104437-25

PB104437-25

or iOF+SD24)
1 iOF 1 (iSD or iOF or iOF/SD+OF) No

ARA iC60 Vigi iC60


PB104472-25

iID

Acti 9 | Catalogue 2014 F-23


Control ARA automatic reclosers
Remote control For iC60 circuit breakers
and iID residual current circuit breakers

The ARA reclosing auxiliary can:


PB106256-40

b Perform automatic reclosing of the associated protection device, after tripping.


b Increase the availability of installations without supervision, isolated, hard of
access and demanding very great availability (mobile telephony systems,
motorways, pumping stations, airports, railways, meteorological stations, service
stations, automatic teller machines, public lighting, tunnels, etc.), by restoring
them to operation without intervention by personnel in the event of a transient fault
(atmospheric disturbances, industrial overvoltages, etc.).
b The operator can choose predefined reclosing program which allows the safety
and availability of facilities to be reconciled taking into account the facility's
environment.
b The circuit is placed in safety configuration by the padlocking device.
PB106257-40

Catalogue numbers
ARA iC60
For circuit breaker Width in 9 mm
modules
1P, 1P+N, 2P Number of Voltage
programs
4 230 V AC, 50 Hz A9C70132 7
3P, 4P
4 230 V AC, 50 Hz A9C70134 7
ARA iID
For residual current circuit breaker Width in 9 mm
modules
2P Number of Voltage
Diagram programs
1 230 V AC, 50 Hz A9C70342 7
DB124065

4 230 V AC, 50 Hz A9C70332


230 V, 50 Hz
4P
21 22 24 1112 14 iC60 or iID 4 230 V AC, 50 Hz A9C70334 7
ARA
Locked OF
Y1 Y2
N P

Legend
DB124060

DB123582

Type Application
1 2 Choice of program
DB124061

4 3
Y1 "Remote" inhibition of automatic reclosing
Y2 Remote control of final reclosing
N 230 V power supply
P
DB123583

DB123584

Locked Automatic recloser inhibition indication contact


21 22 24
OF Indicates the state of the circuit breaker or residual current
circuit breaker (opened or closed)
11 12 14
Indicator Flashing green ARA automatic recloser operational
lamp
Flashing red Reclosing cycle in progress
Fixed red ARA automatic recloser locked at end of reclosing
cycle: circuit breaker or residual current circuit
breaker tripped (open)
Flashing orange ARA automatic recloser not operational

F-24 Acti 9 | Catalogue 2014


Control ARA automatic reclosers (cont.)
Remote control For iC60 circuit breakers
and iID residual current circuit breakers

Operating principle
The ARA automatic recloser makes a number of attempts at reclosing depending on
the program chosen by the user.
The program includes the following settings:
b A time delay before reclosing (TA).
b A reinitialization time delay (TB).
b A maximum number of reclosing attempts.
If, following these attempts, the fault is still present, the device places itself in waiting
for manual reclosing, or final remote reclosing (Y2).

Number of Delay Check time Final


reclosing before reclosing Y2
attempts reclosing
iC60 iID TA TB
1P, 1P+N, 2P: A9C70132 2P: A9C70342 2P: A9C70332
3P, 4P: A9C70134 4P: A9C70334
Program – 1 program 4 programs
1 2 b – b 1 60 s 6 min. Once after
DB124061

4 3
inhibition
F
b – b 3 60 s 2 min.
DB124062

1 2
3 min. 6 min.
3 min. 6 min.
4 3
1 2 b – – 5 60 s 2 min.
DB124063

3 min. 6 min.
3 min. 6 min.
4 3 3 min. 6 min.
3 min. 6 min.
b – – 5 60 s 2 min.
DB124064

1 2
3 min. 6 min.
4 min. 8 min.
4 3 5 min. 10 min.
6 min. 12 min.
1 2 – – b 5 60 s 2 min. Once per cycle
DB124063

4 min. 3 min.
10 min. 6 min.
4 3 1h 10 min.
6h 10 min.
1 2 – – b 15 20 s 30 min.
DB124064

40 s 30 min.
3 min. ...
4 3 3 min.
...
Only 1 program – b –
available

Acti 9 | Catalogue 2014 F-25


Control ARA automatic reclosers (cont.)
Remote control For iC60 circuit breakers
and iID residual current circuit breakers

Permanent fault ARA iC60

OFF
DB404539

Auto On site
NORMAL intervention and
reinitialization
V

Tripping

Time delay Final reclosing


TA Y2
R

Immediate tripping
Reclosing Inhibition
R
Not
reached

Number of
End of time delay Time delay reclosing Exceeded
TB operations
authorized

Permanent fault ARA iID

OFF
DB404538

Auto On site
NORMAL intervention and
reinitialization
V

Tripping

Time delay Final reclosing


TA Y2
R

Immediate tripping
Reclosing Inhibition
(Programs 1 and 2)
R
Not
reached

End of time delay Immediate tripping Number of Exceeded


Time delay reclosing
TB (Programs 3 and 4) operations
authorized

F-26 Acti 9 | Catalogue 2014


Control ARA automatic reclosers (cont.)
Remote control For iC60 circuit breakers
and iID residual current circuit breakers

Connection Without accessories


Terminal Tightening Copper cables
DB123565

torque Rigid Flexible Flexible with


ferrule

DB122945

DB123553

DB123554
3.5 mm
PZ1
10 mm Power supply (N/P) 1 N.m 0.5 to 10 mm2 0.5 to 6 mm2 0.5 to 4 mm2
Inputs (Y1/Y2) 2 x 0.5 to 2 x 2.5 mm2 2 x 0.5 to 2 x 2.5 mm2 2 x 0.5 to 2 x 2.5 mm2

Outputs (OF/Locked) 0.7 N.m 0.5 to 2.5 mm2 0.5 to 2.5 mm2 0.5 to 1.5 mm2
DB123566

2 x 0.5 to 2 x 1.5 mm2 2 x 0.5 to 2 x 1.5 mm2 2 x 0.5 to 2 x 1.5 mm2

8 mm
3.5 mm

F
Technical data
DB123310

Control circuit
Supply voltage (Ue) (N/P) 230 V AC, 50 Hz
Control voltage (Uc) Type 1 inputs (Y1/Y2) 230 V AC (as per IEC 61131-2)
Min. duration of control order (Y2) u 200 ms
Response time (Y2) < 500ms

Clip on DIN rail 35 mm. Consumption y1W


Endurance (O-C) (ARA combined with a circuit breaker)
DB123312

Electrical 5000 cycles


Indication / Remote control
Potential-free changeover Min. 24 V AC/DC, 10 mA
contact output (OF/Locked) Max. 230 V AC ,1 A
Input (Y1/Y2) 230 V AC 5 mA
Additional characteristics
Indifferent position of installation. Degree of protection Device only IP20
(IEC 60529) Device in a modular IP40
enclosure Insulation class II
IP20 IP40
DB123314

Insulation voltage (Ui) 400 V


Degree of pollution (IEC 60947) 3
Rated impulse withstand voltage (Uimp) 6 kV
Operating temperature -25°C to +60°C
Storage temperature -40°C to +70°C
Tropicalization Treatment 2
(relative humidity of 93 % at +40°C)

Weight (g)
Dimensions (mm)
Automatic reclosers
Type ARA
DB123567

135
For 1P, 1P+N, 2P circuit breakers or iID 2P residual current 440v
4P
117 circuit breaker
3P
2P (1P+N) 99 For 3P, 4P circuit breakers or iID 4P residual current circuit breaker 470
1P 81 70
63 3 5.5 44.5
2

85 45

6
80
97

Acti 9 | Catalogue 2014 F-27


Electrical
circuit
control

G-2 Acti 9 | Catalogue 2014


Control, remote control Reflex iC60N, iC60H
Integrated control circuit
breakers (curves B, C, D)

bb Tripping and disconnection device capable of:


vv disconnecting and padlocking (Ø 3 to 6 mm not supplied) in "open" position
vv neutralizing remote control

bb Ti24 interface for direct link


to PLC and Acti 9 Smartlink
PB105980-70

bb IP20 insulated terminals

bb Bistable operation:
does not change state in the
bb Operating state event of electrical power
indicator lamp outage

bb Resetting handle

VisiSafe
bb Positive contact indication
bb Uimp: 6 kV G
bb Ui: 500 V
bb Pushbutton: bb Degree of pollution: level 3
vv manual control:
opening/closing
vv choice of operating
"modes"

bb Longer product service life thanks to:


vv good overvoltage withstand capacity: products designed to provide a high
industrial performance level (degree of pollution, rated impulse withstand voltage
and insulation voltage),
vv high limitation performances,
vv fast closure independent of the speed of resetting of the operating handle.

Legend
DB123765

Ti24 interface
+24VDC V DC power supply
Y3 Remote control by latched order
auto/OFF Circuit-breaker state information
O/C Control circuit state information (open/closed)
0V V DC power supply
DB123516

Y1 Latched order control


Y2 Control by impulse-type
N 230 V AC power supply
P
O/C Control circuit state indication contact
11 12 14
auto/OFF Circuit-breaker tripping indication contact
21 22 24

Acti 9 | Catalogue 2014 G-3


Control, remote control Reflex iC60N, iC60H
Integrated control circuit
breakers (curves B, C, D) (cont.)

IEC/EN 60947-2
The Reflex iC60 devices are integrated control circuit breakers which combine the
following main functions in a single device:
b Remote control by latched and/or impulse-type order according to the 3 operating
modes to be chosen by the user.
b Circuit breaker, to provide:
v circuit protection against short-circuit currents,
v circuit protection against overload currents,
v disconnection in the industrial sector.
PB106239-40

Resetting after a fault is performed manually, by the resetting handle.

The version with Ti24 allows direct interfacing of the Reflex iC60 with a PLC, to:
b Execute remote control (Y3).
b Indicate the state of the control circuit (O/C) and circuit-breaker state information
(auto/OFF).
The Ti24 interface also allows fast, reliable connection of the Reflex iC60 to the
Acti 9 Smartlink thanks to the prefabricated cables.

The iMDU auxiliary allows the Reflex iC60 to be controlled in 24/48 V AC/DC.

Alternating current (AC) 50 Hz


PB106238-40

Ultimate breaking capacity (Icu) as per IEC/EN 60947-2 Service


Voltage (Ue) breaking
capacity (Ics)
Ph/Ph (2P, 3P, 4P) 220 to 240 V 380 to 415 V
Reflex iC60N
Rating (In) 10 to 40 A 20 kA 10 kA 75 % of Icu
63 A 20 kA 10 kA 50 % of Icu
Reflex iC60H
Rating (In) 10 to 40 A 30 kA 15 kA 50 % of Icu

Catalogue numbers
Reflex iC60 circuit breaker
Type 2P 3P 4P
Rating (In) Curve Curve Curve
B C D B C D B C D
Reflex iC60N
With Ti24 interface
10 A A9C61210 A9C62210 A9C63210 A9C61310 A9C62310 A9C63310 A9C61410 A9C62410 A9C63410
16 A A9C61216 A9C62216 A9C63216 A9C61316 A9C62316 A9C63316 A9C61416 A9C62416 A9C63416
25 A A9C61225 A9C62225 A9C63225 A9C61325 A9C62325 A9C63325 A9C61425 A9C62425 A9C63425
40 A A9C61240 A9C62240 - A9C61340 A9C62340 - A9C61440 A9C62440 -
63 A A9C61263 A9C62263 - A9C61363 A9C62363 - A9C61463 A9C62463 -
Without Ti24 interface
10 A - A9C52210 - - A9C52310 - - A9C52410 -
16 A - A9C52216 - - A9C52316 - - A9C52416 -
25 A - A9C52225 - - A9C52325 - - A9C52425 -
40 A - A9C52240 - - A9C52340 - - A9C52440 -
63 A - A9C52263 - - A9C52363 - - A9C52463 -
Reflex iC60H
With Ti24 interface
10 A A9C64210 A9C65210 A9C66210 A9C64310 A9C65310 A9C66310 A9C64410 A9C65410 A9C66410
16 A A9C64216 A9C65216 A9C66216 A9C64316 A9C65316 A9C66316 A9C64416 A9C65416 A9C66416
25 A A9C64225 A9C65225 A9C66225 A9C64325 A9C65325 A9C66325 A9C64425 A9C65425 A9C66425
40 A A9C64240 A9C65240 - A9C64340 A9C65340 - A9C64440 A9C65440 -
Width in 9 mm modules 9 11 13
Vigi iC60 See page B-17 See page B-17 See page B-17
iMDU auxiliary See page E-2 and F-2 See page E-2 and F-2 See page E-2 and F-2
Accessories See page E-2 and E-10 See page E-2 and E-10 See page E-2 and E-10

G-4 Acti 9 | Catalogue 2014


Control, remote control Reflex iC60N, iC60H
Integrated control circuit
breakers (curves B, C, D) (cont.)

Remote control is possible by 3 operating modes to be set using the pushbutton on


b Operating state
the front panel.
DB123517

indicator lamp

Three types of control: Y1, Y2, Y3


N P

DB124370
Centralized
control
(PLC)
b Pushbutton for: 24 V
v "mode" selection auto/ auto/
v opening/closing manual 24 V Y3 OFF O/C 0V 24 V Y3 OFF O/C 0V
control Ti24 Ti24
Reflex iC60 Reflex iC60

Y1 Y2 Y1 Y2
auto/OFF O/C auto/OFF O/C
N P N P
21 22 24 11 12 14 21 22 24 11 12 14

Y2 Y1 Y2 Y1

230 V Zone 1 Zone 2

Operating modes Reflex iC60 without Ti24 interface


Mode 1
DB124371

Mode 1: Reflex iC60 opening/closing, Mode 2 N P


locally or centrally controlled
b The opening/closing orders come from various control
points, and they are taken into account in their order of arrival Reflex iC60
v Y1: latched order local control
v Y2: impulse-type local control

G
v Y3: latched order centralized control
Y1 Y2
auto/OFF O/C
Mode 2: Reflex iC60 opening/closing, N P
possible inhibition of local impulse-type 21 22 24 11 12 14
control
b Y1 is used to inhibit Y2 Y2 Y1
v Y1: local opening/Y2 inhibition latched order control 230 V
v Y2: impulse-type local opening/closing control
v Y3: latched order centralized opening/closing control

Mode 3: Reflex iC60 opening/closing, Reflex iC60 with Ti24 interface


possible inhibition of centralised latched Mode 1
DB124372

PLC
Mode 2 Out In In
order control
Mode 3
b Y1 is used to inhibit Y3 24 V c
v Y3 inhibition local latched order control
auto/ 0V
v Y2: impulse-type local opening/closing control
v Y3: latched order centralized opening/closing control N P 24 V Y3 OFF O/C 0V
Ti24
Reflex iC60

Y1 Y2
auto/OFF O/C
N P
21 22 24 11 12 14
Y2 Y1
230 V

Table of modes
Mode 1 Mode 2 Mode 3
Reflex iC60 without interface Ti24 b Default mode b Possible mode –
Reflex iC60 with interface Ti24 b Possible mode b Possible mode b Default mode

Acti 9 | Catalogue 2014 G-5


Control, remote control Reflex iC60N, iC60H
Integrated control circuit
breakers (curves B, C, D) (cont.)

Power connection Without accessories With accessories


Terminal Rating Tightening Copper cables Al Screw-on Multi-cable
DB123561

torque terminal connection terminal


14 mm 50 mm² for ring
Rigid Flexible or Rigid Flexible
with ferrule terminal cables cables

DB118787
DB122945

DB122946

DB122935

DB118789
Power 10 to 25 A 2 N.m 1 to 25 mm2 1 to 16 mm2 - Ø 5 mm - -
6.5 mm 40 to 63 A 3.5 N.m 1 to 35 mm2 1 to 25 mm2 50 mm2 3 x 16 mm2 3 x 10 mm2
PZ2

Control connection Without accessories


Terminal Tightening Copper cables
DB123562

torque Rigid Flexible Flexible with ferrule


DB122945

DB123553

DB123554
Power supply (N/P) 1 N.m 1 to 10 mm2 1 to 6 mm2 1 to 4 mm2
Inputs (Y1/Y2)
10 mm
3.5 mm
PZ1
Outputs 0.7 N.m 1 to 2.5 mm2 1 to 2.5 mm2 1 to 1.5 mm2
DB123563

(O/C, auto/OFF)

8 mm
3.5 mm

Ti24 interface Spring-loaded 0.5 to 1.5 mm2 0.5 to 1.5 mm2 0.5 to 1.5 mm2
DB123580

terminals

10 mm

3.5 mm

G-6 Acti 9 | Catalogue 2014


Control, remote control Reflex iC60N, iC60H
Integrated control circuit
breakers (curves B, C, D) (cont.)

Technical data
DB123310

Control circuit
Supply voltage (Ue) (N/P) 230 V AC - 50 Hz
Control voltage (Uc) Inputs (Y1/Y2) 230 V AC - 5 mA
(24…48 V AC/DC, with iMDU auxiliary)
Input (Y3) 24 V DC - 5.5 mA
Clip on DIN rail 35 mm. Min. duration of control impulse (Y2) u 250 ms
Response time (Y2) y 200 ms
Consumption y1W
Inrush consumption < 1000 VA
DB123312

Length of control wires Inputs (Y1/Y2) Cable: 100 m


Wires in a sheath: 500 m
Input (Y3) 500 m
Inrush current at 2P 4.2 Â
230 V - 50 Hz 3P 8.2 Â
4P 16.2 Â
Power circuit
Indifferent position of installation.
Max. working voltage (Ue) 400 V AC
Insulation voltage (Ui) 500 V
Rated impulse withstand Set to Disconnected 6 kV
IP20 IP40 voltage (Uimp)
DB123314

Set to Ready 4 kV
Thermal tripping Reference 50°C
temperature
Magnetic tripping Curve B 4 In ± 20 %
Curve C 8 In ± 20 %
Curve D 12 In ± 20 %
Overvoltage category (IEC 60364) IV
Temperature derating See page CA908007
Indication / Remote control
Potential-free changeover Min. 24 V DC - 100 mA
contact outputs Max 230 V AC - 1 A
(O/C, auto/OFF)
Ti24 interface (as per IEC 61131)
Outputs (O/C, auto/OFF) Ti24 interface 24 V DC - 100 mA max
G
Endurance (O-C)
Electrical AC1 - AC7a Up to 50,000 cycles (1)
AC5a - AC5b Up to15,000 cycles (1)
AC7c Up to 20,000 cycles (1)
Mechanical 50,000 cycles
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in a modular IP40
enclosure Insulation class II
Degree of pollution 3
Operating temperature -25°C to +60°C
Storage temperature -40°C to +85°C
Tropicalization Treatment 2
(relative humidity of 93 % at 40°C)
Immunity to voltage dips IEC 61000-4-11 class III
Immunity to power supply frequency variations IEC 61000-4-28 and IACS E10
Immunity to harmonics IEC 61000-4-13 class 2
Immunity to electrostatic Air 8 kV, IEC 61 000-4-2
discharges Contacts 4 kV, IEC 61 000-4-2
Immunity to stray magnetic fields 10 V/m up to 3 GHz, IEC 61000-4-3
Immunity to fast transients 4 kV from 5 to 100 kHz, IEC 61000-4-4
Immunity to shock waves IEC 61000-4-5
Immunity to power frequency magnetic fields 10 V from 150 kHz to 80 MHz,
IEC 61000-4-6
Immunité aux champs magnétiques à la fréquence Level 4 30 A/m to IEC 61000-4-8 and
du réseau IEC 61000-4-9
Conducted emissions CISPR 11/22
Radiated emissions CISPR 11/22
(1) See the derating table according to the load types and ratings

Acti 9 | Catalogue 2014 G-7


Control, remote control Reflex iC60N, iC60H
Integrated control circuit
breakers (curves B, C, D) (cont.)

Weight (g)
Circuit breaker
Type Reflex iC60
2P 480
3P 620
4P 750

Dimensions (mm)
4P 117
DB123564

3P 99 77
2P 81 5.5 44.5

84 45

G-8 Acti 9 | Catalogue 2014


Control, remote control iMDU electrical auxiliary for
Reflex iC60

The voltage matching module allows safety voltages of 24 and 48 V AC/DC to be used
on the control inputs.
PB106245-40

b Only connects to the Reflex iC60 circuit breakers remote controlled by a 220-240 V
control voltage
b Galvanic isolation 6000 V
b Maximum combined power between terminals P and Y1/Y2: 100 mA at 230 V and
25°C.

Catalogue numbers
Electrical auxiliary for Reflex iC60
A9C18195 Type Width in 9 mm
modules
iMDU A9C18195 1

Diagram
An iMDU electrical auxiliary allows up to a maximum of five Reflex iC60 to be controlled simultaneously at the same input.
24/48 V AC/DC 220-240 V AC
DB124310

0V 0V
OF OF
SD SD
Y3 Y3
24 V c 24 V c
Ti24 Ti24
iMDU
Reflex iC60 Reflex iC60
RCA iC60 RCA iC60

N P Y2 Y1 N P Y2 Y1

P Y1/Y2 G

Dimensions (mm) Connection


Type Tightening Copper cables
DB124312
DB124311

torque Rigid Flexible or with


6 mm
ferrule
3 mm
DB122946
DB122945

iMDU 1 N.m 1.5 mm2 1.5 mm2

Technical data
Main characteristics
Control circuit voltage 24…48 V AC/DC
Insulation voltage (Ui) 500 V
Additional characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
enclosure Insulation class II
Operating temperature -20°C to +60°C
Storage temperature -40°C to +80°C
Tropicalisation Treatment 2
(relative humidity 95 % at 55°C)
Weight 53 g

Acti 9 | Catalogue 2014 G-9


Control iCT contactors
Remote control

EN 61095, IEC 1095


DB116619

iCT contactors are available in two versions:


Country approval pictograms
b Contactors without manually-operated
b Contactors with manually-operated.

The breadth of the iCT contactor range satisfies most application cases.
iCT contactors can be combined with auxiliary control, protection and indication functions.

Contactors

iCT 2P

PB107751-34
PB106120-34

PB106124-34

PB106123-34
PB106115-35

manual control
Indication Interference Dual control Control and
iACTs filtering iACTc indication 24 V DC
iCT 4P b This auxiliary iACTp b Used to control iACT24
PB106105-35

allows indication or b This auxiliary is an a contactor in b Allows control and


control of the "open" interference impulse-type indication of a 230 Vac
or "closed" position suppressor which limits mode or to contactor from the Acti 9
of the contactor overvoltages on the combine latched Smartlink or by a PLC, by
power contacts control circuit or impulse-type 24 V DC signals
control orders b Also allows control by a
maintained signal
Time delay iATEt
PB106125-34

b This auxiliary is used to time delay


for iCT and iTL. According to cabling, there are
b iCT contactors can be used 5 possible time delay types:
to remote control applications v 1 for iTL
in alternative networks: v 4 for iCT
v lighting, heating, Function type A: Function type C:
ventilation, roller blinds, late closing late opening
sanitary hot water Delay energizing of contactor b Energize the contactor by closing a push
v mechanical ventilation Function type B: button
b The time delay starts when the control
systems, etc time delay
b Energize the contactor by closing contacts are opened
v load-shedding of
a push button Function type H:
non-priority circuits
b The time delay starts as soon as fixed time operation
the control contacts are closed b Operate the contactor for a pre-determined
time from the moment of energizing

Contactors Contactors auxiliaries


Choice of 50 Hz contactors
Type Contactor Manually-operated contactors
Rating A 16 20 25 40 63 100 16 25 40 63
Auxiliaries Contactors that can be equipped with auxiliaries
iACTs indication Yes Yes Yes Yes
auxiliary
iACTp protection By No No Yes No Yes
auxiliary yellow
clips
iACTc, iATEt By No No Yes No Yes
control auxiliary yellow
clips
iACT24 Non No Yes (for contactors 230 V - 50 Hz) No Yes (for contactors 230 V - 50 Hz)
control auxiliary

G-10 Acti 9 | Catalogue 2014


Control iCT contactors (cont.)
Remote control

b Insulated terminals IP20

Yellow clip
b Clip-on system for electrical
and mechanical connections
between contactors u 25 A and
their auxiliaries
PB106115-39

b Minimum noise

b Large circuit
labeling area

b Mechanical contact
position indicator

G
b Consistent with the entire Acti 9 offer
and with all types of lighting

b Manually-operated contactors have a 4-position


selector switch on their front face:
v automatic operating mode
v temporary "ON" override
v permanent "ON" override: used to lock the contactor in
the ON position during installation maintenance
v shutdown

Choice of 60 Hz contactors
Contactor Manually-operated contactors
16 25 40 63 40
Contactors that can be equipped with auxiliaries
Yes

No Yes

No Yes

No

Acti 9 | Catalogue 2014 G-11


Control iCT contactors (cont.)
Remote control

Catalogue numbers
iCT contactors - 50 Hz
Type Width in 9 mm
modules
1P Rating (In) Control voltage Contact
(V AC) (50 Hz)
AC7a AC7b
16 A 6A 12 1NO A9C22011 2
DB103373-5

A1 1

24 1NO A9C22111 2
48 1NO A9C22211 2
A2 2 220 1NO A9C22511 2
230…240 1NO A9C22711 2
25 A 8.5 A 220 1NO A9C20531 2
230…240 1NO A9C20731 2
2P
16 A 6A 12 2NO A9C22012 2
DB122915

A1 R1 R3

24 2NO A9C22112 2
48 2NO A9C22212 2
A2 R2 R4 220 2NO A9C22512 2
230...240 2NO A9C22712 2
12 1NO+1NC A9C22015 2
DB103377-11

A1 1 R1

24 1NO+1NC A9C22115 2
220 1NO+1NC A9C22515 2
A2 2 R2 230...240 1NO+1NC A9C22715 2
20 A 6A 230...240 2NO A9C22722 2
25 A 8.5 A 24 2NO A9C20132 2
DB103375-10

A1 1 3

48 2NO A9C20232 2
220 2NO A9C20532 2
A2 2 4 230...240 2NO A9C20732 2
220 2NC A9C20536 2
230...240 2NC A9C20736 2
40 A 15 A 220...240 2NO A9C20842 4
63 A 20 A 24 2NO A9C20162 4
220...240 2NO A9C20862 4
100 A - 220...240 2NO A9C20882 6
3P
16 A 6A 220…240 3NO A9C22813 4
DB103378-14

A1 1 3 5

25 A 8.5 A 220…240 3NO A9C20833 4


40 A 15 A 220…240 3NO A9C20843 6
A2 2 4 6 63 A 20 A 220…240 3NO A9C20863 6

4P
16 A 6A 24 4NO A9C22114 4
DB122916

A1 R1 R3 R5 R7

220...240 4NO A9C22814 4


220...240 2NO+2NC A9C22818 4
A2 R2 R4 R6 R8 20 A 6A 220 ...240 4NO A9C22824 4
25 A 8.5 A 24 4NO A9C20134 4
220...240 4NO A9C20834 4
DB122917

A1 1 3 R1 R3

24 4NC A9C20137 4
220...240 4NC A9C20837 4
A2 2 4 R2 R4 220...240 2NO+2NC A9C20838 4
40 A 15 A 220...240 4NO A9C20844 6
220...240 4NC A9C20847 6
DB103381-18

A1 1 3 5 7

63 A 20 A 24 4NO A9C20164 6
220...240 4NO A9C20864 6
A2 2 4 6 8 24 4NC A9C20167 6
220...240 4NC A9C20867 6
220...240 2NO+2NC A9C20868 6
DB122918

A1 1 3 5 R1

220...240 3NO+1NC A9C20869 6


100 A - 220...240 4NO A9C20884 12
A2 2 4 6 R2

G-12 Acti 9 | Catalogue 2014


Control iCT contactors (cont.)
Remote control

Catalogue numbers
iCT manual control contactor 50 Hz
Type Width in 9 mm
modules
2P Rating (In) Control voltage Contact
(V AC) (50 Hz)
AC7a AC7b
16 A 6A 220 2NO A9C23512 2
DB106317-24

A1 1 3

I
230...240 2NO A9C23712 2
P
auto 220 1NO+1NC A9C23515 2
O
A2 2 4 230...240 1NO+1NC A9C23715 2
25 A 8,5 A 24 2NO A9C21132 2
220 2NO A9C21532 2
DB106318-27

A1 1 R1

I
230...240 2NO A9C21732 2
P
auto 40 A 15 A 24 2NO A9C21142 2
O
A2 2 R2 220...240 2NO A9C21842 4
63 A 20 A 24 2NO A9C21162 4
220...240 2NO A9C21862 4
3P
25 A 8,5 A 220...240 3NO A9C21833 4
DB106319-27

A1 1 3 5

I P
40 A 15 A 220...240 3NO A9C21843 6
auto
O
A2 2 4 6

4P
25 A 8,5 A 24 4NO A9C21134 4
DB106320-31

A1 1 3 5 7

I P
220...240 4NO A9C21834 4
auto 40 A 15 A 24 4NO A9C21144 6

G
O
A2 2 4 6 8 220...240 4NO A9C21844 6
63 A 20 A 24 4NO A9C21164 6
220...240 4NO A9C21864 6

Acti 9 | Catalogue 2014 G-13


Control iCT contactors (cont.)
Remote control

Catalogue numbers
iCT contactors - 60 Hz
Type Width in 9 mm
modules
1P Rating (In) Control voltage Contact
(V AC) (60 Hz)
AC7a AC7b
25 A 8.5 A 127 1NO A9C20431 2
DB103373-5

A1 1

220 ...240 1NO A9C20631 2

A2 2

2P
16 A 6A 127 1NO+1NC A9C22415 2
DB122915

R1 R3
DB103375-10

A1 A1 1 3

220...240 1NO+1NC A9C22615 2


25 A 8.5 A 127 2NO A9C20432 2
A2 R2 R4 A2 2 4 220...240 2NO A9C20632 2
127 2NC A9C20436 2
220...240 2NC A9C20636 2
DB103377-11

A1 1 R1

40 A 15 A 127 2NO A9C20442 4


220...240 2NO A9C20642 4
A2 2 R2

3P
25 A 8.5 A 127 3NO A9C20433 4
DB103378-14

A1 1 3 5

220...240 3NO A9C20633 4


40 A 15 A 127 3NO A9C20443 6
A2 2 4 6 220...240 3NO A9C20643 6
63 A 20 A 127 3NO A9C20463 6
220...240 3NO A9C20663 6

iCT manual control contactor 60 Hz


Type Width in 9 mm
modules
2P Rating (In) Control voltage Contact
(V AC) (60 Hz)
AC7a AC7b
40 A 15 A 127 2NO A9C21442 4
DB106317-24

A1 1 3

220...240 2NO A9C21642 4


I P
auto
O
A2 2 4

Operation (Manual control contactor)


Position: O Position: auto Position: I Position: I + P
DB123607

Automatic return to
“auto” position

G-14 Acti 9 | Catalogue 2014


Control iCT contactors (cont.)
Remote control

Connection
Type Rating Lenght Circuit Tightening Copper cables
DB123606

tripping torque Rigid Flexible or


ferrule

DB122945

DB122946
iCT PZ1: 4 mm 16 - 100 A 9 mm Control 0.8 N.m 1.5 to 2.5 mm: 1.5 to 2.5 mm:
2 x 1.5 mm2 2 x 2.5 mm2
16 and 25 A Power 1.5 to 6 mm2 1 to 4 mm2
PZ2: 6 mm 40 A - 63 A 14 mm 3.5 N.m 6 to 25 mm2 6 to 16 mm2
100 A 6 to 35 mm2 6 to 35 mm2
iACTs, iACTp, PZ1: 4 mm - 9 mm - 0.8 N.m 1.5 to 2.5 mm: 1.5 to 2.5 mm:
iACTc, iATEt 2 x 1.5 mm2 2 x 2.5 mm2

Type Terminals Tightening Copper cables


DB124308

torque Rigid Flexible Flexible or


ferrule

DB122945

DB123553

DB123554
3.5 mm
PZ1
9 mm
iACT24 Power supply 1 N.m 0.5 to 10 mm2 0.5 to 6 mm2 0.5 to 4 mm2
(N/P) 2 x 0.5 to 2 x 0.5 to 2 x 0.5 to
Input (Y1/Y2) 2 x 2.5 mm2 2 x 2.5 mm2 2 x 2.5 mm2

Ti24 connector connection


Type Catalogue Copper cables G
DB123580

Spring-loaded
terminals numbers Rigid Flexible
DB122945

DB123553

10 mm
0.4 x 2.5 mm

Ti24 Interface A9XC2412 1 x 0.5 to 1.5 mm2 1 x 0.5 to 1.5 mm2

Ti24 prefabricated cables connection


Type Catalogue numbers Length
Connection for Acti 9 Smartlink
6 short prefabricated A9XCAS06 100 mm
PB107754-10

6 medium-sized prefabricated A9XCAM06 160 mm


6 long prefabricated A9XCAL06 870 mm

Connection for PLC type terminals


6 long prefabricated on a A9XCAU06 870 mm
PB107755-14

single side

24V
DB404857

Y3
24V
O/C
0V

Acti 9 | Catalogue 2014 G-15


Control iCT contactors (cont.)
Remote control

Technical data
DB123309

Power circuit
Voltage rating (Ue) 1P, 2P 250 V AC
3P, 4P 400 V AC
Frequency 50 Hz or 60 Hz
Type of load See page the Technical Guide
Clip on DIN rail 35 mm.
Endurance (O-C)
Electrical 100,000 cycles
Maximum number of switching operation a day 100
DB123300

Additional characteristics
Insulation voltage (Ui) 500 V AC
Pollution degree 2
Rated impulse withstand voltage (Uimp) 2.5 kV (4 kV for 12/24/48 V AC)
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
± 30° vertical. enclosure
Operating temperature -5°C to +60°C (1)
Storage temperature -40°C to +70°C
IP20 IP40
DB123311

Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95 % at 55°C)


ELSV compliance (Extra Low Safety Voltage) for 12/24/48 V AC versions
The product control conforms to the SELV (safety extra low voltage) requirements

(1) In the case of contactor mounting in a enclosure for which the interior temperature is in range
between 50°C and 60°C, it is necessary to use a spacer, cat. no. A9A27062, between each
contactor
DB123331

Spacer cat. no. A9A27062

G-16 Acti 9 | Catalogue 2014


Control iCT contactors (cont.)
Remote control

Mounting accessories

DB124309
7 Sealable screw shields 3P, 4P 25 A A9A15921
for top and bottom 2P 40/63 A A9A15922
3P, 4P 40/63 A A9A15923
10
8 9 mm spacer A9A27062
9 Yellow clips A9C15415
10 Clip-on terminal markers see page E-10

iCT < 25 A
Auxiliaries
Indication
2 iACTs 1NO + 1NC A9C15914
1CO A9C15915
2NO A9C15916
Double control inputs
3 iACTc 230 V AC A9C18308
24 V AC A9C18309
Coil suppression blocs
4 iACTp 12...48 V AC A9C15919
48...127 V AC A9C15918
220...240 V AC A9C15920
Time delay
5 iATEt 24...240 V AC A9C15419
Control and indication iCT u 25 A
6 iACT24 230 V AC A9C15924

Acti 9 | Catalogue 2014 G-17


Control iCT contactors
Remote control
Electrical auxiliaries for iCT

Indication Protection Control


Auxiliaries iACTs iACTp iACTc
Type Indication Interference filtering Impulse/latched control
With Open/Close auxiliary contact 2 protection circuits
PB106120-34

PB106124-34

PB106123-34
Function
b This auxiliary allows indication of the "open" b This auxiliary is an interference b This auxiliary, combined with contactors,
or "closed" position of the contactor power contacts suppressor which limits overvoltages enables them to be controlled by
on the control circuit 2 order types:
v impulse order for local control (input T)
v latched order for centralised control
(input X)
v the last order received takes priority

Wiring diagrams
DB123777

DB123778

DB123779

DB123316

DB123315
23 11 13 13 23 3 1 T

24 12 12 14 14 24 4 2 X

Mounting
b Mounted to the right of iCT b Mounted to the left of iCT b Mounted to the left of iCT
by yellow clips (1) by yellow clips (1)
b By wires
Use
– b The iACTp has 2 separate and
b Mains power outages:
identical circuits, allowing it to be
v < 1 s: keeps its initial status
combined with 2 different one on the
v u 5 s: reset
iCT the other by wires v put back into operation by manual
operation on input X or T.
b Minimum impulse duration: 250 ms
Catalogue numbers A9C15914 A9C15915 A9C15916 A9C15918 A9C15919 A9C15920 A9C18308 A9C18309

Technical specifications
Control voltage V AC 24…240 48 …127 12 …48 220 …240 230…240 24…48
(Ue)
V DC 24…130 – –
Operating Hz 50/60 50/60 50/60
frequency
Width in 9 mm modules 1 2 2
Auxiliary contact b Mininimum: 10 mA at 24 V DC/AC - cos φ = 1 – –
(breaking capacity) b Maximum:
v 5 A at 240 V AC - cos φ = 1
v 1 A at 130 V DC
Number of contacts 1NO + 1NC 1CO 2NO – –
Operating °C -5°C to +50°C
temperature
Storage °C -40°C to +70°C
temperature
Consumption – – OFF load: 3 VA
Inrush (2): 2 VA
Holding (2): 0.2 VA
(1) Electrical and mechanical link.
(2) Maximum consumption of all contactors controlled.

G-18 Acti 9 | Catalogue 2014


Control iCT contactors
Remote control
Electrical auxiliaries for iCT
(cont.)
Control (cont.)
iATEt
Time delay
PB106125-34

b This auxiliary is used to time delay for iCT and iTL. According to cabling, there are 5 possible time delay types:
v 1 for iTL
v 4 for iCT.
Function type A: late closing Function type B: time delay Function type C: late opening Function type H: fixed time operation
b Delay energizing of contactor. b Energize the contactor by closing b Energize the contactor by closing b Operate the contactor for
a push button. a push button. a pre-determined time from the moment
b The time delay starts as soon as the b The time delay starts when the of energizing.
control contacts are closed. control contacts are opened.

U
1
U
1
U
1
U
1
G
0 0 0 0
A1 1 A1 1 A1 1 A1 1
iCT iCT iCT iCT
A2 0 t A2 0 t A2 0 t A2 0 t
T T T T

b Mounted to the left of iCT by yellow clips (1)

A9C15419

24…240
24…110
50/60

2


-20°C to +50°C

-40°C to +80°C

Off-load: 5 VA
Inrush (2): 3 A
Holding (2): 0.2 A

Acti 9 | Catalogue 2014 G-19


Control iCT contactors
Remote control
Electrical auxiliaries for iCT
(cont.)
Control and indication
Auxiliary iACT24
Type Control and indication 24 V DC
With Ti24 connector
PB107751-34

Function
b This auxiliary allows a contactor to be interfaced with the Acti 9 Smartlink interface or a programmable logic controller (PLC)
in 24 V DC (control, O/C indication)
b 230 V AC control
Wiring diagrams
Acti 9 Smartlink or PLC Acti 9 Smartlink or PLC
DB124313

DB124441
Out In In Out In In

24 V DC 24 V DC
P 0V P 0V
24 V Y3 24V O/C 0V 24 V Y3 24V O/C 0V
Ti24 Ti24
iACT24 iACT24

P P
OFF
ON Auto

Wiring with exclusive selector Wiring for non-exclusive 230 V AC and 24 V DC controls
230 V AC control (Y1 = 0) / 24 V DC control (Y1 = 1)
Mounting
b To the left of the iCT contactor using the yellow clips (1).
b When an iACT24 is used, the A1/A2 terminals of the contactors should not be wired. Only the yellow clips integral with the iACT24
should be used for connection to the coil.
Utilization
b 230 V AC interface:
v Y1: enabling of 24 V DC control (Y1 = 1) or inhibition of 24 V DC control (Y1 = 0).
v Y2: 230 V pulse control
b "Ti24" 24 V DC interface:
v Y3: 24 V DC control of iCT closing on rising edge and opening on falling edge
v reading of the contactor status (opened or closed) from the position of the integrated O/C auxiliary contact
v monitoring of connection of the "Ti24" terminal block by the upstream system (PLC, supervision system) via the 24 V terminal (in the
centre of the Ti24 terminal block)
Catalogue numbers A9C15924
Technical specifications
Control voltage V AC 230, +10 %, -15 % (Y2)
(Ue)
V DC 24, ± 20 % (Y3)
Operating Hz 50
frequency
Insulation voltage V AC 250
(Ui)
Rated impulse kV 8
withstand voltage
(Uimp)
Pollution degree 3
Degree of protection IP20B device only
IP40 device in modular enclosure
Width in 9 mm modules 2
Auxiliary contact (O/C) 24 V DC protected output, min. 2 mA, max. 100 mA
Ti24
Contact 1 O/C operating category AC 14
Operating °C -25°C to +60°C
temperature
Storage °C -40°C to +80°C
temperature
Consumption <1 W
Standard IEC/EN 60947-5-1
(1) Mechanical and electrical link.

G-20 Acti 9 | Catalogue 2014


Control iCT contactors
Remote control
Accessories for iCT

Security
Accessories Sealable screw shields Yellow clips Spacer
PB104485-15

PB104486-15

PB104487-15

PB106143-10

PB104483-40
Function
b Designed to cover terminals to avoid contact with device screws. b Ensure the mechanical b Required to reduce temperature
b Allow sealing and/or electrical link rise of modular devices installed side
between contactors and by side.
their auxiliaries. b Recommended to separate
b For iCT: b For iCT: b For iCT: b For iCT: ≥ 25 A electronic devices (thermostat,
3P, 4P - 25 A 2P - 40/63 A 3P, 4P - 40/63 A programmable clock, etc.) from
electromechanical devices (relays,
contactors).
Use
b Bag of 10 upstream/10 downstream b Bag of 10 b Bag of 5
Catalogue numbers A9A15921 A9A15922 A9A15923 A9C15415 A9A27062

Technical specifications
Width in 9 mm modules 4 4 6 – 1
Number of poles 3P, 4P 2P 3P – –

Acti 9 | Catalogue 2014 G-21


Control iCT contactors
Remote control
Technical advice for iCT (cont.)

Operation of the iACT24


O/C 24 V DC output

DB124314
iCT contacts

O/C 24 V DC output

T T

Parameter Min Max


T Time delay between iACT24 closing and indication 100 ms 200 ms

b Minimum duration of 230 V AC pulse (Y2): 200 ms.


b 30 iACT24 closing or opening actuations are authorized per minute: Minimum time
delay between 2 actuations on the iACT4 via Y1,Y2, Y3 (closing or opening of the
iCT coil): 220 ms.
b 10 closing or opening actuations spaced 440 milliseconds apart are authorized
following no loading of the iACT24 during a period of 20 seconds.

Wiring with exclusive selector Wiring for non-exclusive 230 V AC and 24 V DC controls
230 V AC control (Y1 = 0) / 24 V DC control (Y1 = 1)
DB124443

DB124444

Out In In Acti 9 Smartlink or PLC Out In In Acti 9 Smartlink or PLC


24 V DC 24 V DC
0V 0V
P 24 V Y3 24V O/C 0V P 24 V Y3 24V O/C 0V
Ti24 Ti24
iACT24 iACT24

P P
OFF
ON Auto
DB124314

DB124442

Y1 230 V AC Y1 230 V AC

Y2 230 V AC Y2 230 V AC

Y3 24 V DC Y3 24 V DC

iCT status iCT status

G-22 Acti 9 | Catalogue 2014


Control iCT contactors
Remote control
Technical advice for iCT

Consumption
iCT contactors - 50 Hz
Type
1P Rating (In) Control voltage Consumption Max.
(V AC) (50 Hz) power
AC7a AC7b Holding Inrush
16 A 5A 12 3.8 VA 15 VA 1.3 W A9C22011
24 3.8 VA 15 VA 1.3 W A9C22111
48 3.8 VA 15 VA 1.3 W A9C22211
220 3.8 VA 15 VA 1.3 W A9C22511
230…240 2.7 VA 9.2 VA 1.2 W A9C22711
25 A 8.5 A 220 3.8 VA 15 VA 1.3 W A9C20531
230…240 2.7 VA 9.2 VA 1.2 W A9C20731
2P
16 A 5A 12 3.8 VA 15 VA 1.3 W A9C22012
24 3.8 VA 15 VA 1.3 W A9C22112
48 3.8 VA 15 VA 1.3 W A9C22212
220 3.8 VA 15 VA 1.3 W A9C22512
230...240 2.7 VA 9.2 VA 1.2 W A9C22712
12 3.8 VA 15 VA 1.3 W A9C22015
24 3.8 VA 15 VA 1.3 W A9C22115
220 3.8 VA 15 VA 1.3 W A9C22515
230...240 2.7 VA 9.2 VA 1.2 W A9C22715
20 A 6.4 A 230...240 2.7 VA 9.2 VA 1.2 W A9C22722
25 A 8.5 A 24 3.8 VA 15 VA 1.3 W A9C20132
48 3.8 VA 15 VA 1.3 W A9C20232
220 3.8 VA 15 VA 1.3 W A9C20532
230...240 2.7 VA 9.2 VA 1.2 W A9C24732
220 3.8 VA 15 VA 1.3 W A9C20536

G
230...240 2.7 VA 9.2 VA 1.2 W A9C20736
40 A 15 A 220...240 4.6 VA 34 VA 1.6 W A9C20842
63 A 20 A 24 4.6 VA 34 VA 1.6 W A9C20162
220...240 4.6 VA 34 VA 1.6 W A9C20862
100 A - 220...240 6.5 VA 53 VA 2.1 W A9C20882
3P
16 A 5A 220…240 4.6 VA 34 VA 1.6 W A9C22813
25 A 8.5 A 220…240 4.6 VA 34 VA 1.6 W A9C20833
40 A 15 A 220…240 6.5 VA 53 VA 2.1 W A9C20843
63 A 20 A 220…240 6.5 VA 53 VA 2.1 W A9C20863
4P
16 A 5A 24 4.6 VA 34 VA 1.6 W A9C22114
220...240 4.6 VA 34 VA 1.6 W A9C22814
220...240 4.6 VA 34 VA 1.6 W A9C22818
20 A 6.4 A 220 ...240 4.6 VA 34 VA 1.6 W A9C22824
25 A 8.5 A 24 4.6 VA 34 VA 1.6 W A9C20134
220...240 4.6 VA 34 VA 1.6 W A9C24834
24 4.6 VA 34 VA 1.6 W A9C20137
220...240 4.6 VA 34 VA 1.6 W A9C20837
220...240 4.6 VA 34 VA 1.6 W A9C20838
40 A 15 A 220...240 6.5 VA 53 VA 2.1 W A9C20844
220...240 6.5 VA 53 VA 2.1 W A9C20847
63 A 20 A 24 6.5 VA 53 VA 2.1 W A9C20164
220...240 6.5 VA 53 VA 2.1 W A9C20864
24 6.5 VA 53 VA 2.1 W A9C20167
220...240 6.5 VA 53 VA 2.1 W A9C20867
220...240 6.5 VA 53 VA 2.1 W A9C20868
220...240 6.5 VA 53 VA 2.1 W A9C20869
100 A - 220...240 13 VA 106 VA 4.2 W A9C20884

Acti 9 | Catalogue 2014 G-23


Control iCT contactors
Remote control
Technical advice for iCT (cont.)

Consumption (cont.)
iCT manual control contactor 50 Hz
Type
2P Rating (In) Control voltage Consumption Max.
(V AC) (50 Hz) power
AC7a AC7b Holding Inrush
16 A 5A 220 2.7 VA 9.2 VA 1.2 W A9C23512
230...240 2.7 VA 9.2 VA 1.2 W A9C23712
220 3.8 VA 15 VA 1.3 W A9C23515
230...240 2.7 VA 9.2 VA 1.2 W A9C23715
25 A 8.5 A 24 3.8 VA 15 VA 1.3 W A9C21132
220 2.7 VA 9.2 VA 1.2 W A9C21532
230...240 2.7 VA 9.2 VA 1.2 W A9C25732
40 A 15 A 24 4.6 VA 34 VA 1.6 W A9C21142
220...240 4.6 VA 34 VA 1.6 W A9C21842
63 A 20 A 24 4.6 VA 34 VA 1.6 W A9C21162
220...240 4.6 VA 34 VA 1.6 W A9C21862
3P
25 A 8.5 A 220...240 4.6 VA 34 VA 1.6 W A9C21833
40 A 15 A 220...240 6.5 VA 53 VA 2.1 W A9C21843
4P
25 A 8.5 A 24 4.6 VA 34 VA 1.6 W A9C21134
220...240 4.6 VA 34 VA 1.6 W A9C21834
40 A 15 A 24 6.5 VA 53 VA 2.1 W A9C21144
220...240 6.5 VA 53 VA 2.1 W A9C21844
63 A 20 A 24 6.5 VA 53 VA 2.1 W A9C21164
220...240 6.5 VA 53 VA 2.1 W A9C21864

iCT contactors - 60 Hz
Type

1P Rating (In) Control voltage Consumption Max.


(V AC) (60 Hz) power
AC7a AC7b Holding Inrush
25 A 8.5 A 127 3.8 VA 15 VA 1.3 W A9C20431
220 ...240 2.7 VA 9.2 VA 0.9 W A9C20631
2P
16 A 5A 127 3.8 VA 15 VA 1.3 W A9C22415
220...240 2.7 VA 9.2 VA 0.9 W A9C22615
25 A 8.5 A 127 3.8 VA 15 VA 1.3 W A9C20432
220...240 2.7 VA 9.2 VA 0.9 W A9C20632
127 3.8 VA 15 VA 1.3 W A9C20436
220...240 2.7 VA 9.2 VA 0.9 W A9C20636
40 A 15 A 127 4.6 VA 34 VA 1.6 W A9C20442
220...240 4.6 VA 34 VA 1.6 W A9C20642
3P
25 A 8.5 A 127 4.6 VA 34 VA 1.6 W A9C20433
220...240 4.6 VA 34 VA 1.6 W A9C20633
40 A 15 A 127 6.5 VA 53 VA 2.1 W A9C20443
220...240 6.5 VA 53 VA 2.1 W A9C20643
63 A 20 A 127 6.5 VA 53 VA 2.1 W A9C20463
220...240 6.5 VA 53 VA 2.1 W A9C20663

G-24 Acti 9 | Catalogue 2014


Control iCT contactors
Remote control
Dimensions for iCT

Dimensions (mm)
68 68
DB123376

DB123609
49 49
5.5 23.5 36 54 5.5 23.5
18 36

85 45
81 45

2.5 2.5

iCT 16/25 A iCT 40/63 A

68
DB123610

49
54 108 5.5 23.5

85 45

2.5

iCT 100 A

73

G
73
DB123381

DB123382

68
68
49
49
36 54 5.5 23.5
18 36 5.5 23.5

85 45
81 45

2.5 2.5

iCT manual control contactor 16/25 A iCT manual control contactor 40/63 A

68 68 60
DB123379

DB124316

DB123380

49 49 44
9 5.5 23.5 18 5.5 18 5

81 45 45 81 45
81

iACTs iACT24 iATEt


iACTp
iACTc

Acti 9 | Catalogue 2014 G-25


Remote control iTL impulse relays

IEC/EN 60669-2-2
iTL, iTLI,
DB116619

iTLs: IEC/EN 60947-5-1


iTLs, iTLc,
iTLm

Impulse iTL
PB106126-34

PB106128-34
b The impulse relays are used to control,
relays by means of pushbuttons, lighting circuits
consisting of:
v incandescent lamps, low-voltage halogen
lamps, etc. (resistive loads)
v fluorescent lamps, discharge lamps, etc.
(inductive loads)

Remote
Indication
PB106133-34

PB106139-34
iTLs
indication b Allows remote iATLs
indication of its operating b Allows remote
state (open/closed) indication of the
associated impulse relay

Centralised iTLc Centralised control


PB106130-34

PB106137-34

control b Allows centralised iATLc


control of a group of TLc b Used for centralised control,
impulse relays, whilst at thanks to a "pilot line",
the same time retaining of a group of impulse relays
local impulse-type control controlling separate circuit,
while at the same time
maintaining local individual
control of each impulse relay

Latched iTLm Latched control


PB106132-34

PB106138-34

control b Operated by latched


orders from a changeover
iATLm
b Controls the
contact (switch, time associated impulse relay
switch, thermostat). by latched orders from a
Manual control does not changeover contact
work

Impulse relays
G-26 Acti 9 | Catalogue 2014
Remote control iTL impulse relays (cont.)

Impulse relays are used:


b Closing of the impulse relay pole(s) is triggered by an impulse on the coil.
b Having two stable mechanical positions, the pole(s) will be opened by the next impulse. Each impulse received by the coil reverses the
position of the pole(s).
b Can be controlled by an unlimited number of pushbuttons.
b Zero energy consumption.

Changeover contact iTLi Extensions iETL


PB106131-34

PB106134-34
b This impulse relay has a b Used to increase the number of impulse relay poles
changeover contact b Can be installed on the iTL, iTLi, iTLc,
iTLm and iTLs

+ =

Time delay

PB106125-34
Centralised control +
PB106140-34

indication iATLc+s iATEt


b Used for centralised control, thanks to b Combined with an
a "pilot line", of a group of impulse relays impulse relay,
controlling separate circuit, while at the it automatically
same time maintaining local individual disconnects the circuit
PB107752-34

control of each impulse relay after a preset time


b Remote indication of the mechanical
status of each relay
G
Control iATLz
PB106141-34

b Must be used when


installing several
Multi-level centralised illuminated PBs in parallel
PB106136-34

to control an impulse
control iATLc+c relay (prevents operating
b Allows centralised control malfunctions)
of a group of iTLc or “iTL + ATLc” Control and
impulse relays indication 24 V DC
iATL24
b Allows control and
indication of a 230 V AC
impulse relay from the Acti 9
PB106142-63

Step by
Smartlink or by a PLC, by
24 V DC signals
step
b Also allows control by a control
pulsed signal iATL4
b Allows
step-by-step
control of two
circuits via a
single
pushbutton

Impulse relays auxiliaries Specific auxiliaries


Acti 9 | Catalogue 2014 G-27
Remote control iTL impulse relays (cont.)

Mounting accessories

DB123631
11 Yellow clips A9C15415
12 9 mm spacer A9A27062
13 Clip-on terminal markers see page E-10

iTLm iETL

iTL (4P) Mechanical and


electrical link

Electrical link

Auxiliaries
Centralised control iTL (1P - 2P)
2 iATLc (1), (3) 24...240 V AC A9C15404

Indication
3 iATLs (1) 24...240 V AC A9C15405

Centralised control + indication


4 iATLc+s (3) 24...240 V AC A9C15409

Multi-level centralised control iTLI


5 iATLc+c (2), (3) 24...240 V AC A9C15410

Step by step control


6 iATL4 230 V AC A9C15412
Control by illuminated push-buttons
7 iATLz 130...240 V AC A9C15413
Latched control iTLs
8 iATLm (1) 12...240 V AC A9C15414
Time delay control
9 iATEt (4) 24...240 V AC A9C15419
Control and indication
10 iATL24 230 V AC A9C15424

(1) The iATLc, iATLs and iATLm 9 mm auxiliaries are used by


themselves to the right of an impulse relay.
(2) Connection by traditional cabling.
The iATLc+c must be mounted to the right of an iATLc+s
or an iATLc. iTLc
(3) The centralised control functions (iTLc, iATLc,
iATLc+s, iATLc+c) only operate on AC voltage networks.
(4) iATEt: control voltage:
24...240 V AC, 24...110 V DC.

G-28 Acti 9 | Catalogue 2014


PB106126-41
Remote control iTL impulse relays (cont.)

Yellow clip
b A simple clip-on system b Insulated terminals IP20
for flexible auxiliaries
combination and
improved robustness
b For electrical and
mechanical connections

b Built-in or optional auxiliary


b Large circuit function: state indication,
labeling area centralised control, latched
control, control for illuminated
pushbutton,
step-by-step control, time delay

b Disconnection of remote control by


selector switch (except for 4P
b Consistent with the entire Acti 9 single-piece iTL) for maintenance
offer and with all types of lighting operation

b Manual controls on front face: direct


and priority manual control by O-l
toggle
b Mechanical contact position indicator

G
Choice impulse relays auxiliaries
Type Standard iTL Changeover iTLI iTLc iTLm control on iTLs remote
centralised latched order indication
control
Rating A 16 32 16 16 16 16
Control voltage V AC 230/ 130 48 24 12 230/ 230/ 130 48 24 12 230/ 48 24 230/ 230/ 48 24
240 240 240 240 240 240
V DC 110 48 24 12 6 110 110 48 24 12 6 - 110 110 24 12
Auxiliaries
Extension
iETL b b b b b b b b b b b b b b b b b b
Centralised control + indication
iATLc+s b b b b - b b b b - - - - - - b b b
Centralised control
iATLc b b b b - b b b b - - - - - - b b b
Indication
iATLs b b b b - b b b b b b b b b b b b b
Multi-level centralised control
iATLc+c b b b b - b b b b - - b b b - b b b
Latched control
iATLm b b b b b b b b b b b - - - - b b b
Control for illuminated Pushbutton
iATLz b b - - - b b b - - - b b - - b b -
Step by step control
iATL4 b - - - - b b - - - - b - - - b - -
Time delay control
iATEt b b b (*) b - b b b b b (*) - b b b - b b b (*)
Control and indication
iATL24 b - - - - b b - - - - b - - - b - -
(*) iATEt : does not operate on 12 V DC.

Acti 9 | Catalogue 2014 G-29


Remote control iTL impulse relays

Catalogue numbers
iTL impulse relays
Type 1P 2P 3P 4P

DB123624

DB123625

DB123626 + DB123630

DB123627
+
1 NO 2 NO 1 NO + 1NO/NC + 1NO 4 NO
Rating (In) Control voltage (Uc)
(V AC) (V DC)
16 A 12 6 A9C30011 A9C30012 A9C30011 + A9C32016 A9C30012 + A9C32016
24 12 A9C30111 A9C30112 A9C30111 + A9C32116 A9C30114
48 24 A9C30211 A9C30212 A9C30211 + A9C32216 A9C30212 + A9C32216
130 48 A9C30311 A9C30312 A9C30311 + A9C32316 A9C30312 + A9C32316
230...240 110 A9C30811 A9C30812 A9C30811 + A9C32816 A9C30814
32 A 230...240 110 A9C30831 A9C30831 + A9C32836 A9C30831 + 2 x A9C32836 A9C30831 + 3 x A9C32836
Width in 9 mm modules 2 2 4 4

iTLI impulse relays


DB123628

Type 1P

1NO + 1NC
Rating (In) Control voltage (Uc)
(V AC) (V DC)
16 A 12 6 A9C30015
24 12 A9C30115
48 24 A9C30215
130 48 A9C30315
230...240 110 A9C30815
Width in 9 mm modules 2

iETL extensions for iTL and iTLI


Type Width in 9 mm
modules
1P Rating (In) Control voltage (Uc)
(V AC) (V DC)
32 A 230...240 110 A9C32836 2
DB123629

1NO
2P
16 A 12 6 A9C32016 2
DB123630

24 12 A9C32116 2
48 24 A9C32216 2
130 48 A9C32316 2
1NO/NC + 1NO
230...240 110 A9C32816 2

G-30 Acti 9 | Catalogue 2014


Remote control iTLc , iTLm, iTLs
with built-in auxiliary function

Catalogue numbers (cont.)


iTLc impulse relay with centralised control
Type 1P 3P

DB123617

DB123618
5 9

6 8 10

1NO 3P
Rating (In) Control voltage (Uc)
(V AC)
16 A 24 A9C33111 A9C33111 + A9C32116
48 A9C33211 A9C33211 + A9C32216
230...240 A9C33811 A9C33811 + A9C32816
Width in 9 mm modules 2 4

iTLm impulse relay with latched control


DB123986

DB123987
Type 1P 3P

1NO 3P
Rating (In) Control voltage (Uc)
(V AC)
16 A 230...240 A9C34811 A9C34811 + A9C32116
Width in 9 mm modules 2 4
DB123621

DB123622

iTLs impulse relay with remote indication*


Type 1P 3P

5 9

6 8 10

1NO 3P
Rating (In) Control voltage (Uc)
(V AC) (V DC)
16 A 24 12 A9C32111 A9C32111 + A9C32116
48 24 A9C32211 A9C32211 + A9C32216
230...240 110 A9C32811 A9C32811 + A9C32816
Width in 9 mm modules 2 4
(*) Short circuit protection device for indication contacts : 6 A gG fuse.

Acti 9 | Catalogue 2014 G-31


Remote control iTL impulse relays

Connection
Type Rating Circuit Tightening Copper cables
DB123132

torque Rigid or ferrule Flexible or ferrule


11 mm
3.5 mm

DB122945

DB123553
PZ1

iTL, iTLi, iTLc, 16 A Control 1 N.m 0.5 to 4 mm2 1 to 4 mm2


iTLm, iTLs, iETL Power 1.5 to 4 mm2 1.5 to 4 mm2
iTL, iETL 32 A Control 0.5 to 4 mm2 1 to 4 mm2
Power 1.2 N.m 1.5 to 10 mm2 1.5 to 10 mm2
iATLs, iATLc, 1 N.m 0.5 to 4 mm2 1 to 4 mm2
iATLc+s, iATLc+c,
iATLm, iATEt,
iATL4, iATLz

Type Terminals Tightening Copper cables


DB124308

torque Rigid Flexible Flexible or ferrule


DB122945

DB123553

DB123554
3.5 mm
PZ1
9 mm
iATL24 Power supply 1 N.m 0.5 to 10 mm2 0.5 to 6 mm2 0.5 to 4 mm2
(N/P) 2 x 0.5 to 2 x 2.5 mm2 2 x 0.5 to 2 x 2.5 mm2 2 x 0.5 to 2 x 2.5 mm2
Input (Y1/Y2)

Ti24 connector connection


Spring-loaded Type Catalogue Copper cables
DB123580

terminals
numbers Rigid Flexible
DB122945

DB123553

10 mm
0.4 x 2.5 mm

Ti24 interface A9XC2412 1 x 0.5 to 1.5 mm2 1 x 0.5 to 1.5 mm2

Ti24 prefabricated cables connection


Type Catalogue numbers Length
Connection for Acti 9 Smartlink
6 short prefabricated A9XCAS06 100 mm
PB107754-10

6 medium-sized prefabricated A9XCAM06 160 mm


6 long prefabricated A9XCAL06 870 mm

Connection for PLC type terminals


6 long prefabricated on a A9XCAU06 870 mm
PB107755-14

single side

24V
DB404857

Y3
24V
O/C
0V

G-32 Acti 9 | Catalogue 2014


Remote control iTL impulse relays (cont.)

Operation
Switch set to auto Switch set to OFF

DB123623

Technical data
DB123309

Control circuit
iTL and iTLI 16 A iTL 32 A,
iTLc, iTLm, iTLs, iETL 32 A
iETL 16 A
Dissipated power (during the impulse) 1, 2, 3P: 19 VA 19 VA
Clip on DIN rail 35 mm.
Illuminated PB control
4P: 38 VA
Max. current 3 mA (if > use an ATLz) G
Operating threshold Min. 85 % of Un in conformance with
IEC/EN60669-2-2
Duration of the control order 50 ms to 1 s (200 ms recommended)
Response time 50 ms
DB123311

Power circuit
Voltage rating (Ue) 1P, 2P 24 ...250 V AC
3P, 4P 24....415 V AC
Frequency 50 Hz or 60 Hz
Maximum number of operations per minute 5
Maximum number of switching operation a day 100
Indifferent position of installation.
Additional characteristics to IEC/EN 60947-3
Insulation voltage (Ui) 440 V AC
Pollution degree 3
Rated impulse withstand voltage (Uimp) 6 kV
Endurance (O-C)
IP20 IP40
DB123313

Electrical to IEC/EN 60947-3 200,000 cycles (AC21) 50,000 cycles (AC21)


100,000 cycles (AC22) 20,000 cycles (AC22)
Overvoltage category IV
Other characteristics
Degree of protection Device only IP20
(IEC 60529) Device in IP40
modular Insulation class II
enclosure
Operating temperature -20°C to +50°C
Storage temperature -40°C to +70°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95 % at 55°C)

Acti 9 | Catalogue 2014 G-33


Remote control iTL impulse relays
Electrical auxiliaries
for iTL impulse relays
Indication Control
Auxiliaries iATLs iATLc iATLc+s iATLc+c
Type Indication Centralised control Centralised control + Multi-level centralised control
indication
PB106139-34

PB106137-34

PB106140-34

PB106136-34
Function
b Allows remote indication of b Used for centralised control, thanks to a "pilot line", of a b Used to control the centralised
the associated impulse relay group of impulse relays controlling separate networks, controls of a number of impulse
while at the same time maintaining local individual control of relay groups, while at the same time
each impulse relay maintaining local individual control
b And for remote indication and centralised control by level
of the mechanical status of
each relay
Wiring diagrams
DB123233

DB123232

DB123231

DB123235

– – – b Each group, made up of iTLc or


(iTL or iTLl or iTLs) + iATLc+s, must
only contain a single iATLc+c
b Maximum number of impulse relays
that can be controlled:
v 230 V AC: 24
v 130 V AC: 12
v 48 V AC: 5
Mounting
b Mounted to the right of iTL b Mounted to the right of iTL b Mounted to the right of iTL b Without mechanical link with
by yellow clips by yellow clips by yellow clips impulse relays and auxiliaries
Catalogue numbers A9C15405 A9C15404 A9C15409 A9C15410

Technical specifications
Control voltage V AC 24…240 24…240 24…240 24 …240
(Ue) V DC 24…240 – – –
Width in 9 mm modules 1 1 2 2
Auxiliary contact b Mininimum: 10 mA at – b Mininimum: 10 mA at –
(breaking capacity) 24 V AC/DC 24 V AC/DC
b Maximum (IEC 60947-5-1): b Maximum (IEC 60947-5-1):
v 12…240 V AC 6A v 12…240 V AC 6A
v 12…24 V DC 6A v 12…24 V DC 6A
v 15…240 V AC 2A v 15…240 V AC 2A
v 13…24 V DC 2A v 13…24 V DC 2A
Number of contacts – – – –
Operating °C -20°C to +50°C
temperature
Storage °C -40°C to +70°C
temperature

G-34 Acti 9 | Catalogue 2014


Remote control iTL impulse relays
Electrical auxiliaries
for iTL impulse relays (cont.)
Control
iATLm iATEt iATL4 iATLz
Latched control Time delay Step by step control Control by illuminated
push-buttons
PB106138-34

PB106125-34

PB106142-63

PB106141-34
b Combined with an impulse relay, b Combined with an impulse relay, b Allows the step by step sequence b Used to control impulse relays
it operates on latched orders it automatically disconnects the over 2 circuits by illuminated push-buttons,
circuit after a preset time without operating risks

G
DB123230
DB123234

DB123237

DB123552

iTL1 iTL2

– b 5 time setting ranges: b The cycle is as follows: b Provide an iATLz when the
v 1 to 10 s v 1st impulse - iTL 1 closed, iTL 2 open current drawn up by the illuminated
v 6 to 60 s v 2nd impulse - iTL 1 open, iTL 2 closed push-buttons is higher than 3 mA
v 2 to 10 min v 3rd impulse - iTL 1 and 2 closed (this current is sufficient to keep
v 6 to 60 min v 4th impulse - iTL 1 and 2 open the coils energised). Above this
v 2 to 10 h v 5th impulse - iTL 1 closed, iTL 2 open, etc value, fit one extra iATLz per 3 mA.
b For example: for 7 mA,
fit 2 iATLz

b Mounted to the right of iTL b Mounted to the left of iTL b Assembled between 2 impulse relays: b Mounted to the left of iTL
by yellow clips by yellow clips according to the auxiliarisation table by yellow clips by yellow clips
A9C15414 A9C15419 A9C15412 A9C15413

12…240 24…240 230 130…240


6…110 24…110 – –
1 2 4 2
– – – –

– – – –
-20°C to +50°C

-40°C to +70°C

Acti 9 | Catalogue 2014 G-35


Remote control iTL impulse relays
Electrical auxiliaries
for iTL impulse relays (cont.)
Control and indication
Auxiliaire iATL24
Type Control and indication 24 V DC
With Ti24 connector
PB107752-34

Function
b This auxiliary allows a impulse relay to be interfaced with the Acti 9 Smartlink interface or a programmable logic controller (PLC)
in 24 V DC (control, O/C indication)
b 230 V AC control
Wiring diagrams
Acti 9 Smartlink or PLC Acti 9 Smartlink or PLC
DB124319

DB124445
Out In In Out In In

24 V DC 24 V DC
P 24V Y3 24V O/C 0V 0V P 24 V Y3 24V O/C 0V 0V
Ti24 Ti24

iATL24
iATL24

P P

Wiring with exclusive selector 230 V AC and 24 V DC controls Wiring for non-exclusive 230 V AC and 24 V DC controls
Mounting
b To the left of the iTL impulse relay using the yellow clips (1).
b When an iATL24 is used, the A1/A2 terminals of the impulse relay should not be wired. Only the yellow clips integral with the iATL24
should be used for connection to the coil.
Utilization
b 230 V AC interface:
v Y1: enabling of 24 V DC control (Y1 = 1) or inhibition of 24 V DC control (Y1 = 0).
v Y2: 230 V pulse control
b "TI24" 24 V DC interface:
v Y3: 24 V DC control of iTL closing on rising edge and opening on falling edge
v reading of the impulse relay status (opened or closed) from the position of the integrated O/C auxiliary contact
v monitoring of connection of the "Ti24" terminal block by the upstream system (PLC, supervision system) via the 24 V terminal (in the
centre of the Ti24 terminal block)
Catalogue numbers A9C15424
Technical specifications
Control voltage V AC 230, +10 %, -15 % (Y2)
(Ue)
V DC 24, ± 20 % (Y3)
Operating Hz 50
frequency
Insulation voltage V AC 250
(Ui)
Rated impulse kV 8
withstand voltage
(Uimp)
Pollution degree 3
Degree of protection IP20B device only
IP40 device in modular enclosure
Width in 9 mm modules 2
Auxiliary contact (O/C) 24 V DC protected output, min. 2 mA, max. 100 mA
Ti24
Contact 1 O/C operating category AC 14
Operating °C -25°C to +60°C
temperature
Storage °C -40°C to +80°C
temperature
Consumption <1 W
Standard IEC/EN 60947-5-1
(1) Mechanical and electrical connection.

G-36 Acti 9 | Catalogue 2014


Remote control iTL impulse relays
Electrical auxiliaries
for iTL impulse relays (cont.)
Operation of the iATL24
O/C 24 V DC output

DB124314
iTL contacts

O/C 24 V DC output

T T

Parameter Min Max


T Time delay between iATL24 closing and indication 100 ms 200 ms

b Minimum duration of 230 V AC pulse (Y2): 200 ms.


b 30 iATL24 closing or opening actuations are authorized per minute: Minimum time
delay between 2 actuations on the iATL24 via Y1,Y2, Y3 (closing or opening of the
iTL coil): 440 ms.
b 10 closing or opening actuations spaced 440 milliseconds apart are authorized
following no loading of the iATL24 during a period of 20 seconds.

Wiring with exclusive selector 230 V AC and 24 V DC controls Wiring for non-exclusive 230 V AC and 24 V DC controls
DB124446

DB124447

Out In In Acti 9 Smartlink or PLC Out In In Acti 9 Smartlink or PLC


24 V DC 24 V DC
P 24 V Y3 24V O/C 0V
Ti24
0V
P 24 V Y3 24V O/C 0V
Ti24
0V
G
iATL24 iATL24

P P
DB124448

DB124449

Y1 230 V AC Y1 230 V AC

Y2 230 V AC Y2 230 V AC

Y3 24 V DC Y3 24 V DC

iTL status iTL status

Acti 9 | Catalogue 2014 G-37


Remote control iTL impulse relays

Security
Accessories Yellow clips Spacer
PB106143-10

PB104483
Function
b Ensure the mechanical and/or electrical b Required to reduce temperature rise of modular devices installed side by side.
link between impulse relays and their b Recommended to separate electronic devices (thermostat, programmable
auxiliaries (set of 10). clock, etc.) from electromechanical devices (relays, contactors).
Catalogue numbers A9C15415 A9A27062

Technical specifications
Width in 9 mm modules – 1

Dimensions (mm)
71
DB123375

67
49
18 36 5.5 23.5

86 81 45

iTL 1P iTL+iETL
iTLc iTL 4P
iTLm
iTLs
iTLi
iETL

71
DB123383

DB123380

67 69 60
49 49 44
18 36 5.5 23.5 9 5.5 23.5 18 5

86 81 45 81 45 81 45

4
iATLc+s iATLc iATEt
iATLc+c iATLs
iATLz iATLm
iATL4

68
DB124316

49
18 5.5

81 45

iATL24

G-38 Acti 9 | Catalogue 2014


Control iTL+ high-performance impulse
Remote control
relays

EN 60669-2-2

The iTL+ high-performance impulse relay allows The iTL+ high-performance impulse relay is used for push-button control of lighting
remote control of single-phase circuits. It is circuits consisting of:
b incandescent lamps, low-voltage halogen lamps, etc. (resistive loads)
designed for demanding applications.
b fluorescent tubes, discharge lamps, etc. (inductive loads).
PB107132-35

PB104483-35

iTL+
Type Rating Width in 9 mm
modules
1P+N
N L 16 A A9C15032 2+1 (1)
DB106156

A1 1 3
DB124139

A2 2 4

(1) Supplied with a 9 mm spacer (cat. no. A9N27062): to be used for mounting the iTL+
alongside a circuit breaker, contactor, impulse relay, etc., in order to maintain optimal operation.
iTL+ iTL+

d
It is compulsory:
- to connect the neutral
- to keep the same control circuit connection
"A1: phase", "A2: neutral"
- to use the same phase for connection of the power and control
G
Spacer cat. no. A9N27062 functions.

Operation
Green indicator Indicator extinguished
DB124160

L N
DB123966

A1 1 3

A2 2 4

Connection
Type Rating Tightening Copper cables
DB123655

torque Rigid or flexible Rigid or flexible


10 mm with ferrule without ferrule
3.5 mm
DB123656

DB123657

PZ1 iTL+ 16 A 1 N.m 2 x 1.5 mm2 2 x 2.5 mm2


1 x 4 mm2

Acti 9 | Catalogue 2014 G-39


Control iTL+ high-performance impulse
Remote control
relays (cont.)

They combine the benefits of static switching and electromechanical technology:


small size, little temperature rise.

b Silent
b Large number of switching operations

b Green indicator on the front panel:


PB107132-40

v fixed green: ON/OFF control by


push button
v flashing green: forced starting
v extinguished: forced stoppage

b Operating mode selection push


button:
v ON/OFF control by push button
v forced starting b Orange indicator:
v forced stoppage output contact closed

b Equivalent performances with


all types of lamps

Following a mains failure, the iTL+ returns to 0 position (forced stoppage)


irrespective of its initial state.

Technical data
DB123309

Control circuit
Coil voltage (Uc) 230 V AC
Frequency 50 Hz
Inrush power 11 VA
Holding power 1.1 VA
Control by luminous push button Max. current 5 mA
Clip on DIN rail 35 mm. Control order duration 50 ms to 1 s (recommended 200 ms)
Power circuit
Voltage rating (Ue) 230 V AC
Frequency 50 Hz
Electrical load Minimum 20 W
DB123311

Maximum 3600 W
Max. number of switching operations per minute 6
Other characteristics
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
Indifferent position of installation. enclosure Insulation class II
Endurance (O-C) Electrical 5.000.000 cycles (AC21 - AC22)
Noise level at activation < 30 dBA
Operating temperature -5°C to +55°C
Storage temperature -40°C to +60°C
IP20 IP40
DB123313

Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95 % at 55°C)

Weight (g)
High-performance impulse relays
Type iTL+
1P+N 70

G-40 Acti 9 | Catalogue 2014


Control iCT+ high-performance
Remote control
contactors

EN 60669-2-2

iCT+ high-performance contactors allow remote iCT+ high-performance contactors can be used for remote control of applications on
control of single-phase circuits. AC networks:
b lighting, heating, ventilation, roller blinds, domestic hot water
They are designed for demanding applications.
b mechanical ventilation systems, etc.
b load shedding on non-priority circuits.
PB107130-35

PB104483-35
PB107131-35

iCT+
Type Rating Contact Width in 9-mm
modules
Standard 1P+N
20 A 1 NO A9C15030 2+1 (1)
E57636

N L
A1 1 3

Standard 1P+N 1P+N with Spacer


manual control
A2 2 4

1P+N with manual control


20 A 1 NO A9C15031 2+1 (1)
DB124140

N L
E57646

A1 1 3

I
auto
iCT+ iCT+ O
A2 2 4

(1) Supplied with a 9 mm spacer (cat. no. A9N27062): to be used for mounting the iCT+
alongside a circuit breaker, contactor, impulse relay, etc., in order to maintain optimal operation.
G
Spacer cat. no. A9N27062

d
It is compulsory:
- to connect the neutral
L N
DB404607

- to keep the same control circuit connection


"A1: phase", "A2: neutral"
- to use the same phase for connection of the power and control
functions.
A1 1 3

A2 2 4

Operation (manual-control contactor)


Permanent stoppage Auto Temporary forced starting
DB124156

Automatic return to
"auto" mode

Acti 9 | Catalogue 2014 G-41


Control iCT+ high-performance
Remote control
contactors (cont.)

They combine the benefits of static switching and electromechanical technology:


small size, little temperature rise.
b Silent
b Large number of
switching operations
b Green indicator on the front panel:
PB137131-40

v fixed green: auto operation


v flashing green: temporary forced
starting
v extinguished: permanent stoppage

b Operating mode selection push


button:
v auto operation
v temporary forced starting* b Orange indicator:
v permanent stoppage output contact closed
b Equivalent performances with
all types of lamps
b No derating

Following a mains failure, the iCT+ returns to "auto" operating mode irrespective of
its initial state.
Connection
Type Tightening Copper cables
DB123655

torque Rigid or flexible Rigid or flexible


10 mm with ferrule without ferrule
3.5 mm
DB123656

DB123657
PZ1 iCT+ 1 N.m 2 x 1.5 mm2 2 x 2.5 mm2
1 x 4 mm2

Technical data
Control circuit
Coil voltage (Uc) 230 V AC (± 10 %)
DB123309

Frequency 50 Hz
Inrush power 11 VA
Holding power 1.1 VA
Power circuit
Voltage rating (Ue) 230 V AC (± 10 %)
Frequency 50 Hz
Clip on DIN rail 35 mm. Electrical load Minimum 20 W
Maximum 3600 W
DB123311

Max. number of switching operations per minute 6


Other characteristics
Endurance (O-C) Electrical 5.000.000 cycles
Pollution degree 3
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
Indifferent position of installation. enclosure Insulation class II
Operating temperature -5°C to +55°C

IP20 IP40 Storage temperature -40°C to +60°C


DB123313

Tropicalization (IEC 60068-1) 2 (relative humidity of 95 % at 55°C)

Weight (g)
High-performance contactors
Type iCT+
Standard 1P+N 70
1P+N with manual control 70

G-42 Acti 9 | Catalogue 2014


Control iPB pushbuttons
Local control

IEC 60669-1 and IEC 60947-5-1


b iPB pushbuttons are used to control electric circuits by means of pulses.

Catalogue numbers
iPB pushbuttons
Type Single Double Single + indicator light

Diagram

Pushbutton Colour Grey Red Grey Grey Green/red Grey/grey Grey Grey Grey Grey
Indicator Power - - - - - - 110…230 V AC 12…48 V AC/DC
light supply
Colour - - - - - - Green Red Green Red
Cat. no. A9E18030 A9E18031 A9E18032 A9E18033 A9E18034 A9E18035 A9E18036 A9E18037 A9E18038 A9E18039
Width in 9 mm modules 2 2 2

Connection
G
Tightening Copper cables
DB123133

torque Rigid Flexible or ferrule


DB122945

DB122946

4 mm
PZ1

9 mm 1 N.m 0.5 mm2 min. 0.5 mm2 min.


2 x 2.5 mm2 max. 2 x 2.5 mm2 max.

b Phase-separated wall that can be divided to allow the teeth of all types of comb
busbar to pass through.
b Staggered terminals to simplify connection.

Dimensions (mm) Technical data


Main characteristics
DB122832

Pollution degree 3
Power circuit
Voltage rating (Ue) 250 V AC
Current rating (Ie) 20 A
Additional characteristics
Endurance (O-C) 30,000 operations AC22 (cos j = 0.8)
Operating temperature -35°C... +70°C
Storage temperature -40°C... +80°C
Tropicalization Treatment 2 (relative humidity 95 % at 55°C)
LED indicator light Consumption: 0.3 W
Service life: 100,000 hours of constant lighting
efficiency
Maintenance-free indicator light
(non-interchangeable LEDs)

Acti 9 | Catalogue 2014 G-43


Control iSSW linear switches
Local control

IEC 60669-1 and IEC 60947-5-1


b iSSW linear switches are used for the manual control of electric circuits.

Catalogue numbers
iSSW linear switches
Type 2 positions 3 positions

Contact 1 changeover switch 2 changeover switches 1 NO + 1NC 1 changeover switch 2 changeover switches
Diagram

Cat. no. A9E18070 A9E18071 A9E18072 A9E18073 A9E18074


Width in 9 mm modules 2 4 2 2 4

Connection
Tightening Copper cables
DB123134

torque Rigid Flexible or ferrule


DB122945

DB122946

4 mm
PZ1
9 mm 1 N.m 0.5 mm2 min. 0.5 mm2 min.
2 x 2.5 mm2 max. 2 x 2.5 mm2 max.

b Phase-separated wall that can be divided to allow the teeth of all types of comb
busbar to pass through.
b Staggered terminals to simplify connection.

Dimensions (mm) Technical data


DB 122834

Main characteristics
Pollution degree 3
Power circuit
Voltage rating (Ue) 250 V AC
Current rating (Ie) 20 A
Additional characteristics
Endurance (O-C) 30,000 cycles AC22 (cos j = 0.8)
Operating temperature -20°C... +50°C
Storage temperature -40°C... +70°C
Tropicalization Treatment 2 (relative humidity 95 % at 55°C)

G-44 Acti 9 | Catalogue 2014


Panel indicators DIN rail selector switches iCMB,
iCMD, iCME, iCMC, iCMV
and iCMA
Control
Selector switches iCMB iCMD iCME
Type Two-pole with zero setting 4-way 2-way for electronic circuits

In compliance with standards IEC 60947-3 (EN 60947-3) IEC 60947-3 (EN 60947-3) IEC 60947-3 (EN 60947-3)
VDE 0660 part. 107 VDE 0660 part. 107 VDE 0660 part. 107
UL UL UL
PB107120-38

PB107121-38

PB107122-38
Function
b This two-pole selector switch with b This 4-way selector switch allows control of b This 2-way selector switch is used
zero setting allows manual control of a circuit with operating priorities specially for the control of electronic circuits
a circuit with 2-way operation with a of low voltage and current level
stop position

Wiring diagrams
1 3 5 7 1 3 5 7 1 3
DB123860

DB123861

DB123862
10 2 0 1 23 4 12

2 6 2 4

G
2

Use
Example: electrically controlled metal Example: fan control: b Voltage range from 30 mV to 600 V AC
screen: b position 0 = stop
b position 1 = raising b position 1 = override operation, slow speed
b position 0 = stop b position 2 = override operation, high speed
b position 2 = lowering b position 3 = remote control
b position 4 = automatic operation
Catalogue numbers A9E15120 A9E15121 A9E15122

Technical specifications
Rated voltage (Ue) V AC 415 415 See following table
Maximum V 440 440 440
operating voltage
Rating A 10 10 See following table
Operating Hz 50/60 50/60 50/60
frequency
Width in 9-mm modules 4 4 4
Breaking capacity – – V AC V DC
(resistive load) 1V 5A 3A
12 V 1.2 A 0.7 A
24 V 0.7 A 0.4 A
48 V 0.45 A 0.25 A
110 V 0.25 A 0.13 A
240 V 0.15 A 0.08 A
300 V 0.13 A 0.07 A
440 V 0.1 A 0.05 A
Operating °C -20…+55 -20…+55 -20…+55
temperature
Storage °C -25…+80 -25…+80 -25…+80
temperature

Acti 9 | Catalogue 2014 G-45


Panel indicators DIN rail selector switches
iCMB, iCMD, iCME, iCMC, iCMV
and iCMA (cont.)

iCMC iCMV iCMA


2-way key-actuated 7-position voltmeter 4-position ammeter

IEC 60947-3 (EN 60947-3) IEC 60947-3 (EN 60947-3) IEC 60947-3 (EN 60947-3)
VDE 0660 part. 107 VDE 0660 part. 107 VDE 0660 part. 107
UL UL UL
PB107123-38

PB107118-38

PB107119-38
b 2-way key-actuated selector switch with b This 7-position voltmeter selector switch b This 4-position ammeter selector switch makes it possible, with
locking in one or the other position makes it possible, with a single voltmeter, to a single ammeter (using current transformers), to measure in
measure in succession the voltages (phase-to- succession the currents of a three-phase circuit
phase and phase-to-neutral) of a three-phase
circuit

1 3
DB123869

DB123146

DB123145

12 iCMV

iCMA
2 4

– – –

A9E15123 15125 15126

415 415 415


440 440 440

10 10 10
50/60 50/60

4 4 4
– – –

-20…+55 -20…+55 -20…+55

-25…+80 -25…+80 -25…+80

G-46 Acti 9 | Catalogue 2014


Panel indicators DIN rail selector switches
iCMB, iCMD, iCME, iCMC, iCMV
and iCMA (cont.)

Connection
Tightening Copper cables

DB123270
torque Flexible or rigid with ferrule

DB122945
PH1

0.35 N.m < 1.5 mm2


DB123310

b Connection by jumper terminals with captive screws.

Technical data
Clip on DIN rail 35 mm. Additional characteristics
Degree of protection Device only IP20
Endurance (O-C) Electrical 1,000,000 switching operations
Mechanical 2,000,000 switching operations (AC21A-3 x 440 V)

Weight (g)
Selector switches
Type
iCMA 58

G
iCMB 58
iCMC 70
iCMD 58
iCME 44
iCMV 58

Dimensions (mm)
71
DB123857

36 4 60

60

Acti 9 | Catalogue 2014 G-47


G-48 Acti 9 | Catalogue 2014
Indication

Acti 9 | Catalogue 2014 H-1


Monitor iIL indicator lights
Indication

IEC 60947-5-1
b iIL indicator lights light up to indicate that a voltage is present.
Catalogue numbers
iIL indicator lights
Type Single Double Flashing light Three-phase
voltage presence
indicator light
PB105256-40

PB105257-40

PB105256-40

PB105258-40
Diagram
DB122563

DB122564

DB122565

DB122566
Colour Red Green White Blue Yellow Green/red White/ Red Red/red/red
white
Cat. no.
12...48 V AC/DC A9E18330 A9E18331 A9E18332 A9E18333 A9E18334 A9E18335 - - -
110...230 V AC A9E18320 A9E18321 A9E18322 A9E18323 A9E18324 A9E18325 A9E18328 A9E18326 -
230...400 V AC - - - - - - - - A9E18327
(3 phases)
Width in 9 mm 2 2 2 2
modules

Connection
Tightening Copper cables
DB123137

torque Rigid Flexible or ferrule


DB122945

DB122946

4 mm
PZ1
9 mm 1 N.m 0.5 mm2 min. 0.5 mm2 min.
2 x 2.5 mm2 max. 2 x 2.5 mm2 max.

b Phase-separated wall that can be divided to allow the teeth of all types of comb
busbar to pass through.
b Staggered terminals to simplify connection.

Dimensions (mm) Technical data


DB122833

Main characteristics
Pollution degree 3
Power circuit
Operating frequency 50...60 Hz
Flashing frequency 2 Hz
Additional characteristics
Operating temperature -35°C... +70°C
Storage temperature -40°C... +80°C
Tropicalization Treatment 2 (relative humidity 95 % at 55°C)
LED indicator light Consumption per indicator light: 0.3 W
Service life: 100,000 hours of constant lighting
efficiency
Maintenance-free indicator light
(non-interchangeable LEDs)

H-2 Acti 9 | Catalogue 2014


Measurement and indication SO bells and iRO buzzers

SO and iRO
Audible indication in housing and the tertiary sector.

Catalogue numbers
Bell and buzzer
Type Width in 9 mm
modules
056679md_SE-35

PB107163-35

SO bell Voltage (Ue)


230 V AC 15320 2

DB123820
8…12 V AC 15321 2

iRO buzzer
230 V AC A9A15322 2
DB123821

8…12 V AC A9A15323 2

Operating frequency 50...60 Hz


SO iRO

Connection
Tightening Copper cables
DB123271

torque Rigid Flexible or ferrule

DB122945

DB122946
3.5 mm
DB123309

PZ1
12 mm 1.3 N.m < 4 mm2 < 4 mm2

Technical data
Clip on DIN rail 35 mm.
Main characteristics SO iRO
Consumption 8…12 V AC 3.6 VA
220…240 V AC 5 VA
DB123311

Additional characteristics
Degree of protection Device only IP40
(IEC 60529) Device in modular IP20
enclosure
Operating temperature -10°C to +40°C
Indifferent position of installation. Storage temperature
Sound level (at a distance of 60 cm)
-25°C to +60°C
80 dBA 70 dBA
H
IP20 IP40 Weight (g)
DB123313

Bell and buzzer


Type
SO 77
iRO 64

Dimensions (mm)
18 6 44 22
DB123147

81 45

SO bell and iRO buzzer

Acti 9 | Catalogue 2014 H-3


Measurement, indication iTR transformers

NF EN 60742, EN and IEC 61558-2-6, Approval NF USE


Bell transformers and safety transformers allow for a very low voltage
(ELV 8 V, 12 V or 24 V) to be obtained from a low voltage network (LV 230 V).

All Schneider Electric transformers are:


b Safe: primary and secondary circuits are perfectly insulated by each other
b Resistant to short-circuit currents thanks to the built-in device
b Class II with terminal shield (optional).
PB107156-35

PB107158-35

Catalogue numbers
Bell transformer
Type Width in 9 mm
modules
Power Secondary
voltage
4 VA 8 V AC A9A15214 4
E56759

1 230 V 7

4 8V 8
4 VA 8-12 V AC A9A15213 4
E56760

1 230 V 7
8 VA 8-12 V AC A9A15216 4
16 VA 8-12 V AC A9A15212 4

4 6 8V 8
12 V
25 VA 12-24 V AC A9A15215 6
E56761

1 230 V 7

4 6 12 V 8
24 V

Safety transformer
Type Width in 9 mm
modules
Power Secondary
voltage
1 230 V 11 16 VA 12-24 V AC A9A15218 10
DB124153

25 VA 12-24 V AC A9A15219 10

8 10 12 V 12
24 V

1 230 V 11 40 VA 12-24 V AC A9A15220 10


DB124154

63 VA 12-24 V AC A9A15222 10

6 8 10 12
24 V

1 230 V 11
DB124155

6 8 10 12
12 V

Operating frequency 50/60 Hz

Terminal shield
Type Width in 9 mm
modules
15228 4
15229 6
15230 10

H-4 Acti 9 | Catalogue 2014


Measurement, indication iTR transformers (cont.)

Connection
Tightening Copper cables

DB123272
torque Rigid Flexible or with
6 mm ferrule
6 mm

DB122945

DB122946
0.5 N.m < 2.5 mm2 < 2.5 mm2
PZ1

Technical data
Main characteristics
Primary voltage 230 V AC ±10 %
Secondary voltage For bell transformers 8-12-24 V AC ±15 %
on load For safety 12-24 V AC ±5 %
DB123310

transformers
Transformer Rated Off load voltage
catalogue numbers secondary voltage
A9A15214 8V 12 V
A9A15213 8V 12 V
12 V 16 V
A9A15216 8V 13 V
Clip on DIN rail 35 mm. 12 V 18 V
A9A15212 8V 13 V
12 V 18 V
A9A15215 12 V 16 V
DB123312

24 V 32 V
A9A15218 12 V 14 V
24 V 28 V
A9A15219 12 V 14 V
24 V 28 V
A9A15220 12 V 14 V
24 V 28 V
Bell transformer: indifferent position of installation. A9A15222 12 V 14 V
Safety transformer: vertical position. 24 V 28 V
Additional characteristics

H
Degree of protection Device only IP20 with terminal shield
(IEC 60529)
Operating temperature -20°C to +55°C
IP20
DB123957

Storage temperature -25°C to +80°C

Note: Transformers have an off load operating voltage that is higher than the rated voltage.
For loads that are sensitive to overloads (electro-magnetic circuits), the transformer must be
made to operate at ln. After operation of the protection device upon an overload, cut-off the power
supply and let the transformer cool down before restart.

Acti 9 | Catalogue 2014 H-5


Measurement, indication iTR transformers (cont.)

Weight (g)
iTR
Type Cat. no. Weight
Bell A9A15212 384
A9A15213 240
A9A15214 237
A9A15215 633
A9A15216 275
Safety A9A15218 1082
A9A15219 1125
A9A15220 1190
A9A15222 1309

Dimensions (mm)
36 54 90 5 39 16
DB123215

89 45

A9A15212 A9A15215 A9A15218


A9A15213 A9A15219
A9A15214 A9A15220
A9A15216 A9A15222

H-6 Acti 9 | Catalogue 2014


Lighting, time
and energy
management

Acti 9 | Catalogue 2014 I-1


Twilight switches IC100, IC2000, IC2000P+,
IC 100k, IC Astro

Twilight

P111637

P111639
switches

P116858
P83237
P83237

P106856
IC100 IC2000
Adjustable from 2 to 100 lux. Adjustable from 2 to 2000 lux. It comes with a standard
It comes with a wall-mounted cell. wall-mounted or switchboard cell.
P111640

P116867
P83237

IC2000P+ IC Astro
It has 3 customisable pre-set programs It operates without photoelectric cell and calculates
and 3 setting ranges from 2 to 2100 lux. sunrise and sunset times according to its
Its 4 keys and large screen facilitate its geographic position.
programming. It can be customised by using its
It comes with a wall-mounted cell. programmation function.
P116853

P116856

P116858

P116859

IC 100k
Adjustable from 2 to 99000 lux.
Its 4 keys and large screen facilitate its programming.
It comes with a digital wall-mounted or a switchboard cell.

I-2 Acti 9 | Catalogue 2014


Twilight switches IC100, IC2000, IC2000P+,
IC 100k, IC Astro (cont.)

Selection table
IC100 IC2000 IC2000P+

P111637 + P83237

P111639 + P116858 + P106856

P111640 + P83237
Function
The IC100 controls closing The IC2000 control closing of a contact The IC2000P+ controls lighting
of a contact when brightness when brightness decreases and drops according to brightness and time.
decreases and drops below below the selected threshold. They control If brightness drops below the set
the selected threshold. opening of a contact when brightness threshold (twilight function: IC) and
It controls opening of a contact increases and rises above the selected if the time program allows relay
when brightness increases and threshold closing (time switch function),
rises above the selected threshold then the lighting circuit is activated
Wiring diagrams
L L L
P106857

P106858

P106859
*
3 4 L 35 L1 3 5

1 2

N L N 2 46 N 2 46
N N N

Catalogue numbers 15482 CCT15284 CCT15368 15483 (1)

Technical specifications
Delivered with Wall-mounted cell Switchboard cell Wall-mounted cell Wall-mounted cell
(15281) (CCT15268)
Optional accessories Wall-mounted cell (CCT15268) Switchboard cell Wall-mounted cell Wall-mounted cell (CCT15268)
(15281) (CCT15268)
Wall-mounted cell Switchboard cell
(CCT15268) (CCT15281)
Adjustable brightness threshold 2 to 100 lx 2 to 2000 lx Range 1: 2 to 50 lx
Range 2: 60 to 300 lx
Range 3: 350 to 2100 lx
Voltage rating (Ue) (+10 %, -15 %) 230 V AC, 50/60 Hz 230 V AC, 50/60 Hz 230 V AC, 50/60 Hz
Consumption 6 VA 6 VA 3 VA
Operating temperature -20°C to +50°C -25°C to +50°C -20°C to +50°C
Width (9 mm modules) 2 5 5
Insulation class Class II Class II Class II
Degree of protection IP20B IP20B IP20B
Output contact rating cos j = 1 16 A 16 A 16 A

I
(under 250 VAC) cos j = 0.6 10 A 10 A 10 A
Time delays (On and Off) 20 s (On) u 60 s Adjustable from 20 to 140 s
80 s (Off) (80 s by default)
Operating accuracy – – < ±1 s / day at 20 °C.
Monitoring indicator light, not time delayed, Red Red –
lit when brightness is less than the threshold
Contact switching indicator light Green Green –
LCD liquid crystal display – – Back-lit
Program saving by lithium battery – – ■
Operating reserve – – 5-6 years
Location for instruction manual on front face – ■ ■
Cabling test function with a push-button on front face – ■ –
Number of channels 1 1 1
Control by brightness detection ■ ■ ■
Coupling with weekly programming – – 42 switching times
Minimum switching: 1 min
Switching accuracy: 1 s

Control by calculation of sunrise/sunset times – – –

Languages: (1) English, french, spanish, italian, german, portuguese, swedish, dutch, finnish, norwegian/danish. (2) English, french, spanish, portuguese, hungarian, polish, roma
Acti 9 | Catalogue 2014 I-3
Twilight switches IC100, IC2000, IC2000P+,
IC 100k, IC Astro (cont.)

IC 100k IC Astro
IC 100k+ 1C IC 100k+ 2C IC100kp+ 1C IC100kp+ 2C IC Astro 1C IC Astro 2C
P116853 + P116858

P116854

P116855 + P116858

P116856

P116866

P116867
The IC 100k+ 1C/2C control closing of a contact The IC100kp+ 1C/2C control lighting according The IC Astro astronomic programmable twilight
when brightness decreases and drops below the to brightness and time. switch is used to start and stop an electric load
selected threshold. It controls opening of a contact If brightness drops below the set threshold (twilight (e.g. lighting) according to sunrise and sunset
when brightness increases and rises above the function: IC) and if the time program allows relay times, without a brightness detector.Sunrise and
selected threshold closing (time switch function), then the lighting circuit is sunset times are calculated automatically by the
activated IC Astro according to the geographic parameters
configured by the user

L L L L
P106862

P106863

P106860

P106861
L L 13 5
LN 45 6 LN C2
Ext C2
– + – +
Ext1 Ext2
Ext1/
Ext2
Ext1/
Ext1 Ext2
C1 C1
C1
123 1 23 N 24 6 N 24 6
N N N N

CCT15250 (2) CCT15252 (2) CCT15490 (2) CCT15492 (2) CCT15223 (2) CCT15243 (2)
(3) (3) (3) (3) (3)
CCT15251 CCT15253 CCT15491 CCT15493 CCT15224 CCT15244 (3)

Digital wall-mounted cell (CCT15260) Digital wall-mounted cell (CCT15260) – Memory key (alone)
Memory key (alone) (CCT15861) (CCT15861)
Digital wall-mounted cell (CCT15260) Digital wall-mounted cell (CCT15260) Programming kit for PC (CCT15860)
Digital switchboard cell (CCT15261) Digital switchboard cell (CCT15261) Memory key (alone) (CCT15861)
Programming kit for PC (CCT15860) Programming kit for PC (CCT15860)
Memory key (alone) (CCT15861)
1 to 99000 lx 1 to 99000 lx According to sunrise/sunset times

230 V AC, 50/60 Hz 100-240 V AC, 50/60 Hz 230 V AC, 50/60 Hz 100-240 V AC, 50/60 Hz 230 V AC, 50/60 Hz
3 VA 3 VA 3 VA 6 VA
-30°C to +50°C -30°C to +50°C -25°C to +45°C
4 6 4 6 5
Class II Class II Class II
IP20C IP20C IP20B
16 A 16 A 16 A
10 A 10 A 10 A
Adjustable from 0 to 59.59 min. Difference in sunset and/or sunrise times
adjustable separately by ±120 min.
– – –
– – –

– – –
Back-lit Back-lit Back-lit
b b b
10 years 10 years 6 years
– – b
– – –
1 2 1 2 1 2
b b –
– 84 switching times 84 switching times (not including sunrise/sunset)
Operating accuracy: < ±1 s / day at 20°C Minimum time between 2 switching operations: 1
Minimum switching: 1 min min.
Switching accuracy: 1 s Switching accuracy: 1 s
Time accuracy: ±1 s /day
– – b

czech, slovak, bulgarian, greek, slovene, serbian, croatian. (3) English, french, italian, german, swedish,dutch, finnish, danish, russian, ukrainian, latvian, lituanien, estonian, turkish.

I-4 Acti 9 | Catalogue 2014


Accessories selection table
Wall-mounted cell Switchboard Programming Memory Digital wall- Digital
cell kit for PC key mounted cell switchboard
cell
P83237

P116858

P106856

P93580

P93581

P116858

P116859
Function
Wall-mounted photoelectric cell Switchboard Consists of a Saving and Digital wall-mounted Digital wall-
photoelectric cell programming device, duplicating photoelectric cell mounted
a memory key, a CDROM programs photoelectric cell
and a 2 m USB cable
Mounting
b Delivered with its Delivered b Delivered with its – – b Delivered with its fixing device.
fixing device for IC100 with 1 m cable fixing device b Cell connection:
and IC200P+ and its fixing b Cell connection: v by double insulation 2-conductor
b Replaced by device by double insulation cable:
CCT15268 for spare 2-conductor cable, - 0.5 - 2.5 mm2 for CCT15260
part use not to be laid next to - 0.25 - 1.5 mm2 for CCT15261
b Cell connection: mains cables or water v Not to be laid next to mains cables
by double insulation ducts, maximum or water ducts, maximum length:
2-conductor cable, not length: 100 m - 100 m (2 x 1.5 mm2)
to be laid next to mains - 50 m (2 x 0.75 mm2)
cables or water ducts,
maximum length: 25 m
Catalogue no. – CCT15268 15281 CCT15860 CCT15861 CCT15260 CCT15261

Technical spécifications
Degree of IP54 IP65 IP54 – – IP55 IP66
protection IK05 – IK05 – – – –
Operating -40°C to +70°C -40°C to +70°C -40°C to +70°C – – -40°C to +70°C -40°C to +70°C
temperature
Horizontally – – 90° – – 90° 90°
orientable

Load table
Type of lighting (230 V AC) Max. power (for higher power, relay with a contactor)
IC100 IC2000 IC2000P+ IC Astro IC 100k
Incandescent and halogen lamps 2300 W 2300 W 2300 W 2300 W 2600 W
Non-corrected / serial-corrected / dual mounted 2300 VA 2300 VA 26 x 36 W, 26 x 36 W, 26 x 36 W,
fluorescent tubes with conventional ballast 20 x 58 W, 20 x 58 W, 20 x 58 W,
10 x 100 W 10 x 100 W 10 x 100 W
Parallel corrected fluorescent tubes with conventional 400 VA 400 VA 10 x 36 W, 10 x 36 W, 10 x 36 W, 6 x 58 W,
ballast 6 x 58 W, 6 x 58 W, 2 x 100 W
2 x 100 W 2 x 100 W

I
Fluorescent tubes with electronic ballast – – 9 x 36 W, 9 x 36 W, 650 VA max.
6 x 58 W 6 x 58 W
Dual-mounted fluorescent tubes with electronic ballast 300 VA 300 VA 5 x (2 x 36 W), 5 x (2 x 36 W), –
3 x (2 x 58 W) 3 x (2 x 58 W)
Fluocompact lamps with electronic ballast 9 x 7 W, 7 x 11 W, 9 x 7 W, 7 x 11 W, 9 x 7 W, 7 x 11 W, 9 x 7 W, 7 x 11 W, 22 x 7 W, 18 x 11 W,
7 x 15 W, 7 x 20 W, 7 x 15 W, 7 x 20 W, 7 x 15 W, 7 x 20 W 7 x 15 W, 7 x 20 W 16 x 15 W, 16 x 20 W,
7 x 23 W 7 x 23 W 14 x 23 W
Fluocompact lamps with conventional ballast 1500 VA 1500 VA – – –
Parallel-corrected mercury and sodium vapour lamps 400 VA 400 VA 250 VA 250 VA 800 VA max. (80uF)
Non-corrected/ serial-corrected mercury and sodium 1000 VA 1000 VA – – –
vapour lamps
Motor – – – – 2300 VA max.

Acti 9 | Catalogue 2014 I-5


Twilight switches IC100, IC2000, IC2000P+,
IC 100k, IC Astro (cont.)

Specific technical data


IC2000P+
External input
Voltage rating (Ue) 230 V AC, +10 %, -15 %
Frequency 50/60 Hz
Input current y 2.5 mA
Consumption y 0.4 mW
Cable length y 100 m
IC Astro
Programming longitude -180° (East) to +180° (West) in steps of 1°
Programming latitude -90° (South) to +90° (North) in steps of 1°
External inputs for external control with a standard switch or b 1 input "Ext1" for IC Astro 1C
a push-button b 2 inputs "Ext1" and "Ext2" for IC Astro 2C
v consumption: < 0.5 mA
v cable length: y 100 m
Programming accessories b Programming kit for PC consists of a programming device, a memory key, a CDROM and
a 2 m USB cable
b Memory key for saving and duplicating programs
IC 100k, IC Astro
Programming accessories b Programming kit for PC consists of a programming device, a memory key, a CDROM and
a 2 m USB cable
b Memory key for saving and duplicating programs
Memory key delivered on front face for IC100kp+ 1C, IC100kp+ 2C and IC Astro
External inputs
External inputs for external control with a standard switch or b 1 input "Ext" for 1 channel versions
a push-button b 2 inputs "Ext1" and "Ext2"for 2 channels versions
Voltage rating (Ue) b 230 V AC, +10 %, -15 % for 1 channel versions
b 100-240 V AC +10 %, -15 % for 2 channels versions
Frequency 50/60 Hz
Input current y 0.5 mA
Consumption y 130 mW
Cable length y 100 m

I-6 Acti 9 | Catalogue 2014


Twilight switches IC2000P+, IC Astro
Practicle advices

IC2000P+
The IC 2000P+ uses its time programming to define lighting On and Off periods:
b According to three pre-set time programs:
v "DAYPROG": On time programming from 7 am to 8 pm a validation
of the IC function from 7 am to 8 pm,
v "NIGHTPROG": On time programming from 5 am to 8 am and from 6 pm
to 11 pm a validation of the IC function on these two operating periods,
v "EMPTYPROG": Off time programming throughout the day a no validation
of the IC function. These programs can be modified if necessary.
b According to a customised operating period, with possibility of copying to the other days.
It is equipped with the following functions:
v consideration of periods of absence (holidays),
v temporary or permanent On or Off override,
v remote control of lighting override by NO external contact,
v consideration of change to “summer/winter” time, automatic or manual,
v permanent liquid crystal display: of time and minutes, of day of the week, of the
contact output status and current program.

4h 23 h Example
P106883

1
Time switch Lighting of a shop window, in the evening, at a time variable according to brightness
function 0 and switch-off at a set time (e.g. 11 pm). Then in the morning, lighting at a set time
Threshold (e.g. 4 am) and switch-off at a time variable according to brightness (see Fig. 1).
Brightness
Configuration
This consists of recording in the memory:
b The language.
1
b The year, month, day and time.
IC2000P+
output 0 b One of the 3 pre-set programs:
v "DAYPROG": "On" time programming from 7 am to 8 pm V validation of the IC
Fig. 1. function from 7 am to 8 pm,
v "NIGHTPROG": "On" time programming from 5 am to 8 am and from 6 pm to
11 pm V validation of the IC function on these two operating periods,
"EMPTYPROG": "Off" time programming throughout the day V no validation of the
L IC function. These programs can be modified.
DB124534

b The brightness threshold. Once this phase is over, your IC 2000P+ operates
*
in AUTO mode according to the items you have chosen.
100 m max L 1 3 5 100 m max
* On override Programming
external contact The IC2000P+ is used to manage time programs. It allows:
b Creation of a new program with the possibility of copying to the other days.
b Viewing programs in memory.
b Modification of a program in memory, of the time, date, summer/winter time.
b Partial or total deletion of the program (date, time and language are kept).
b Modification of the brightness threshold.
N 46
b Separate setting of the time delay on switch-on and switch-off.

N Move to On/Off override


Fig. 2. b Press briefly (< 2 s) and simultaneously the 2 keys "-", "+" (value setting and
navigation keys) on the front face to move to "MAN ON" or "MAN OFF".
b Press the keys for more than 2 s to move to "PERM ON" or "PERM OFF".
b Supply of terminal 1 overrides the IC 2000P+ output to the "On" position.
1 Time switch
P106884

This external override takes priority over the product On/Off override function
function

I
0 (see Fig. 2, 3).
Brightness
threshold
1

0 IC function
1

0 IC2000P+
output

L
1

0
1 1
IC2000P+
0 output

Fig. 3.

Acti 9 | Catalogue 2014 I-7


Twilight switches IC2000P+, IC Astro (cont.)
Practicle advices

IC Astro
The IC Astro is configured according to the place of installation.
b The place of installation of the IC Astro can be configured:
v either by selecting a country and a town,
v or by its geographic coordinates (latitude, longitude).
b The IC Astro allows:
v addition or deletion of a switch-off/switch-on switching operation (Off-On)
between the sunset and sunrise times,
v different programmes each day,
v difference in sunset and/or sunrise times, adjustable separately by ±120 min.
according to local constraints (mountains, buildings, etc.),
v consideration of periods of absence (holidays),
v remote control of lighting override by external standard switch or push-button
via the external input (1 external input per channel),
v re-initialisation of programmes,
v automatic switching to “summer-winter” time,
v permanent display by liquid crystals: hours and minutes, day of the week,
contact output status, and current programme,
v manual waiver of the lighting On/Off programme, permanently or temporarily
(up to the next switching operation).
v back-lighting of the screen.

22 h 6h
Example
P106885

Automatically lighting On and Off a shop window in Paris according to sunset and
sunrise, example the 20th June.
b At night (10 pm) the lighting switch-on.
Fig. 3. b At the morning (6 am) the lighting switch-off.

Configuration
This consists of writing in the memory:
b The language.
b The place of installation, either:
22 h 23 h 5h 6h
P106886

v by its position (Argentina, China, etc.) and by the closest town,


v by its geographic coordinates (latitude, longitude, time difference with respect to
GMT) (a map is provided with the product).
Fig. 4. b The year, month, day and time.
b Once this phase is complete, IC Astro will calculate the sunrise and sunset times
and propose a default programme (operation from sunset to sunrise) (see Fig. 3).

Programming an Off period


The IC Astro offers the possibility of adding an "Off" period (programmed switch-off
-120 min +120 min -120 min +120 min and switch-on) inside the programme, between the sunrise and sunset times
P106887

(by default it is proposed from 11 pm to 5 am) (see Fig. 4).

Modifying programming and configuration


Fig. 5. The twilight switch allows:
b Creation of a new customised programme with possibility of copying onto the
other days.
b Display of programmes in memory.
b Deletion, modification or addition of an automatic or programmed switching
operation.
P106888

On
b Partial or total deletion of the programme (date, time and language are kept).
IC Astro Off b Modification of time, date, summer/winter time.
b Temporary cancellation of the "On" periods by configuring start and end dates
1 and Times of absence (holidays).
b Adjustment of difference in sunset and/or sunrise times by ± 120 min. according to
Ext. contact 0 local constraints (mountains, buildings, etc.) (see Fig. 5).

Move to On/Off override


b Briefly press (<2 s) at the same time on the 2 keys "-", "+": (value setting
Output
and navigation keys) on the front face to move to "ON TEMP" or "OFF TEMP".
Fig. 6. b Hold down (>2 s) the keys to move to "ON PERM" or "OFF PERM".
b The supply of input 5 forces the IC Astro output to the “ON” position.
This override takes priority over the product On/Off override function (see Fig. 6).

I-8 Acti 9 | Catalogue 2014


Twilight switches IC100, IC2000, IC2000P+,
IC 100k, IC Astro (cont.)

Connection
Type Tightening torque Copper cables
DB123132

Rigid Flexible or with ferrule


8 mm
5 mm

DB122945

DB123553
IC100, IC2000P+ 1.2 N.m y 6 mm2 y 6 mm2
PZ1 IC2000, IC Astro, IC 100k 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2

IC100, IC Astro are mechanical compatible with electrical distribution comb busbar.

Weight (g)
Twilight switches
IC100 173
IC2000 280
IC2000P+ 323
IC Astro 132
IC 100k+/kp+ 1C / IC 100k+/kp+ 2C 183/ 352

Dimensions (mm)
60 60
5
DB124541

DB124543

DB124544
63
45 5 44 45 5 44 16
18 38

45 85 45 80 83.5
45 83

IC100 IC2000 IC2000P+


60 64
P106864

P106865

45 5 44 36 54 5 44

45 85 45 90

IC Astro 1C/2C IC 100k+ 1C/2C, IC100kp+ 1C/2C

Cells
38 <9
DB124545

DB124546

P106866

max. 8
ø15.2 ø13.5
ø 20
38 ø15.2 1
ø20
13 20
63 I
8-9
10 max.

ø 5-10

Standard switchboard cell (15281) Fixed externally in vertical position by 2 ø 4 mm screws Digital switchboard cell (CCT15261)

ø18
DB124555

DB124547

DB124548

ø9
ø5
27.2 27.2 1.5 94
ø9
20

116
25
R5.5 ø4
25 9.5 84.3 ø9

61 36
43.5
Wall-mounted cell (delivered with IC100, IC2000P+ ) Standard and digital wall-mounted cell (CCT15268, CCT15260)

Acti 9 | Catalogue 2014 I-9


Time switches IHP, IH, IHH, ITM

Time The 45 mm intuitive switches


switches

P111627

P111625

P111624

P111626
IHP 1c IHP 2c IHP+1c IHP+2c
Automatically switch On and Off loads according to the program entered by the user with 4 keys and
a display, they operate on a weekly cycle: the same program is repeated week after week.
P111633

059236N

IHP DCF 1c + ANT DCF


Synchronised on the frankfort transmitter via the ANT DCF antenna.

The 18 mm intuitive switches


P131535

P131536

IHP 1c/+ 1c
Automatically switch On and Off loads according to the program entered by the user with 4 keys
and a display, they operate on a weekly cycle: the same program is repeated week after week.

I-10 Acti 9 | Catalogue 2014


The 54 mm The 18 mm
mechanical switches mechanical switches
P116860

P116862

P116616

P111614

P111613
IH 60mn 1c SRM IH 24h 1c SRM/ ARM IH 24h 2c ARM IH 24h 1c SRM/ ARM IHH 7j 1c ARM
Automatically switch On and Off loads according
P116619

P116863

to the program entered by the user they operate daily


on a weekly cycle.

IH 24h + 7j 1+1c ARM IH 7j 1c ARM


Automatically switch On and Off loads according to the program
entered by the user they operate on an hourly, daily or weekly cycle:
the same program is repeated hour after hour (IH 60mn), day after
day (IH 24h) or week after week (IH 7j).

The multifunctional switch


P111612

ITM 4c-6E
They operate with weekly or annual time programming distributed across 1, 2, 3 or 4 channels,
I
6 inputs to condition the functions.

Acti 9 | Catalogue 2014 I-11


Time switches IHP, IH, IHH, ITM (cont.)

Selection table
The time switches control opening and closing of one or more separate circuits according to a programming pre-set by the user:
b by memorisation of On and Off switching operations for the IHP switches
b by positioning of jumpers or captive segments on a programming dial for the mechanical IH switches.
An IHP or IH time switch is chosen according to the following criteria:

Designation Number Cycle Minimum Number Saving Width Override Output contact Time changeover
of period time between of switching on mains (modules controls changeover (summer / winter)
channels (d: day) 2 switching operations cut off of 9 mm) On / Off switch
operations (cos j =1)

The 45 mm intuitive switches


IHP 1c 1 24 h 1 min. 56 6 years 5 On / Off 16 A Auto
and/or 7 d
IHP + 1c 1 24 h 1s 84 6 years 5 On / Off 16 A Auto
and/or 7 d
IHP 2c 2 24 h 1 min. 56 6 years 5 On / Off 16 A Auto
and/or 7 d
IHP + 2c 2 24 h 1s 84 6 years 5 On / Off 16 A Auto
and/or 7 d
IHP DCF 1c (1) 1 24 h 1s 42 4 years 5 On / Off 16 A Auto
and/or 7 d
The 18 mm intuitive switches
IHP 1c 18 mm 1 24 h 1 min. 56 10 years 2 On / Off 16 A Auto
and/or 7 d
IHP + 1c 18 mm 1 24 h 1 min. 84 10 years 2 On / Off 16 A Auto
and/or 7 d
The multifunctional switch
ITM 4C-6E (2) 4 60 min., 1s (3) 5 years 10 On/Off (5) 10 A Auto
24 h,
7 d, 7 d
+ dated d
The 54 mm mechanical switches
IH 60mn 1c SRM 1 60 min. 37.5 s 48 On - 48 Off none 6 On 10 A Manual
IH 24h 1c SRM 1 24 h 15 min. 48 On - 48 Off none 6 On 16 A Manual
IH 24h 1c ARM 1 24 h 15 min. 48 On - 48 Off 200 h (4) 6 On 16 A Manual
IH 24h 2c ARM 2 24 h 30 min. 24 On - 24 Off 150 h 6 On 16 A Manual
IH 7j 1c ARM 1 7 days 2h 42 On - 42 Off 200 h (4) 6 On 16 A Manual
IH 24h + 7j 1+1 24 h 45 min. 16 On -16 Off 150 h 6 On 16 A Manual
1+1c ARM + 7 days + 12 h + 7 On -7 Off
The 18 mm mechanical switches
IHH 7j 1c ARM 1 7 days 2h 42 On - 42 Off 100 h 2 On / Off 16 A Manual
IH 24h 1c ARM 1 24 h 15 min. 48 On - 48 Off 100 h 2 On / Off 16 A Manual
IH 24h 1c SRM 1 24 h 15 min. 48 On - 48 Off none 2 On / Off 16 A Manual
Accessories
Programming kit (6)
Memory key (6)
Memory cartridge (7)
ANT DCF antenna

(1) The IHP DCF is synchronised on the Frankfurt 's DCF77 radio station via the ANT DCF antenna.
(2) 4 output channels and 6 condition inputs.
(3) 45 time brackets in weekly time programming, 15 time brackets in annual time programming, 20 different pulses in pulse programming.
(4) 110 h for 100 V CA supply voltage.
(5) On/Off via an override input or a condition input.
(6) For IHP +1c and IHP+ 2c.
(7) For ITM 4c-6E.

I-12 Acti 9 | Catalogue 2014


Back-lit "Absence Screwless Mechanical Input for Instruction Memory Cat. no.
display, for connection compatibility external manual holder key
random holidays" with electrical control on front face supplied
function function distribution comb with the
and pulse busbars product
programming
(8)

b b b b CCT15850 (13)

b b b b 1 input b b CCT15851 (13)

b b b b CCT15852 (13)

b b b b 2 inputs b b CCT15853 (13)

Random b b 15857
function

b b CCT15854 (14)

Random and b b b b CCT15837 (14)


pulse function

Pulse function b b b 15270

b CCT15338
b CCT16364
b CCT15365
15337
b CCT15367
15366

15331
15336
15335

CCT15860
CCT15861
15280
15858

(8) Pulse programming allows switching operations of a duration less than one minute (adjustable from 1 to 59 s); a pulse control always has priority.
I
(9) English, Russian, Ukrainian, Latvian, Lituanien, Estonian languages.
(10) English, Bulgarian, Greek, Slovene, Serbian, Croatian languages.
(11) English, Hungarian, Polish, Romanian, Czech, Slovak languages.
(12) French, English, Italian, Spanish, German, Portuguese languages.
(13) French, English, Swedish, Dutch, Finnish, Norwegian/Danish languages.
(14) French, English, Italian, Spanish, German, Portuguese, Dutch languages.

Acti 9 | Catalogue 2014 I-13


Time switches IHP, ITM

Selection table Programmable time switches


IHP 1c IHP2c IHP+1c IHP+2c
P111627

P111625

P111624

P111626
Function
b These time switches automatically switch on and off loads according to the program entered by the user
b They operate on weekly cycle: the same program is repeated week after week
b They offer automatic summer/winter time change and allow to adjust it according to where you are located
b The program can be overriden temporary or permanently by pressing 2 keys on the product
b They also offer holidays program, by configuring the starting and ending dates of the absence.

b A memory key (CT15861) and a programming kit (CCT15860)


can be used to duplicate on another IHP+ 1C/2c or to save
the program created by the contractor (see "Accessories selection table")
Wiring diagrams
P106873

P106874

P106875

P106876
L 1 3 5

Ext1&2

N 2 4 6
L N

Catalogue Number CCT15850(5) CCT15852(5) CCT15851(5) CCT15853(5)

Technical specifications
Voltage rating (Ue) 230 V AC, ±10 %, 50/60 Hz 230 V AC, ±10 %, 50/60 Hz 230 V AC, ±10 %, 50/60 Hz 230 V AC, ±10 %, 50/60 Hz

Consumption 4 VA 7 VA 4 VA 7 VA
Output contact Cos j = 1 16 A 16 A 16 A 16 A
current (250 V AC) Cos j = 0.6 10 A 10 A 10 A 10 A
Degree of protection IP20B IP20B IP20B IP20B
Operating temperature -10°C to +50°C -10°C to +50°C -10°C to +50°C -10°C to +50°C
Time accuracy ± 1 s per day at 20°C ± 1 s per day at 20°C ± 1 s per day at 20°C ± 1 s per day at 20°C

Saving of program Lifetime 6 years 6 years 6 years 6 years


and time by lithium Back-up 6 years 6 years 6 years 6 years
battery time,
cumulated
mains
cut off

(1) English, russian, ukrainian, latvian, lituanien, estonian.


(2) English, bulgarian, greek, slovene, serbian, croatian.
(3) English, hungarian, polish, romanian, czech, slovak.
(4) French, english, italian, spanish, german, portuguese.
(5) French, english, swedish, dutch, finnish, norwegian/danish.
(6) French, english, italian, spanish, german, portuguese, dutch.

I-14 Acti 9 | Catalogue 2014


Multifunctional time switch
IHP DCF 1c IHP 1c IHP+1c ITM 4c-6E
18 mm 18 mm
P111633

P111630

P131535

P131536
b Weekly or annual time programming to be distributed over 1, 2, 3 or 4 channels.
6 inputs to condition these functions
b A memory cartridge can be used to duplicate on another ITM or to save
the program created by the contractor

b A memory key (CT15861) and


a programming kit (CCT15860) can
be used to duplicate on another IHP

Switch, push-button
P106877

P106878

P107021

P107022

twilight switch,
thermostat, motion
control switch...
6 x 230 V AC
inputs

Sealable cover

Location
for instruction
manual

Removable memory
cartridge (optional)

15857 CCT15854(6) CCT15837(6) 15270

230 V AC, ±10 %, 50/60 Hz 230 V AC, +10 %, 230 V AC, +10 %, 230 V AC, ±10 %, 50 Hz
-15 %, 50/60 Hz -15 %, 50/60 Hz

I
2 VA 2.3 VA 2.3 VA 4.5 VA
16 A 16 A 16 A 10 A
10 A 4A 4A 6A
IP20B IP20B IP20B IP20B
-10°C to +50°C -25°C to +55°C -25°C to +55°C -5°C to +50°C
1 s on 1 million years thanks ± 0.5 s per day ± 0.5 s per day ± 1 s per day at 20°C
to the synchronisation on the DCF at 25°C at 25°C
Frankfurt's DCF77 radio station
via the ANT DCF
12 years 10 years 10 years 10 years
4 years 10 years 10 years 5 years

(1) English, russian, ukrainian, latvian, lituanien, estonian.


(2) English, bulgarian, greek, slovene, serbian, croatian.
(3) English, hungarian, polish, romanian, czech, slovak.
(4) French, english, italian, spanish, german, portuguese.
(5) French, english, swedish, dutch, finnish, norwegian/danish.
(6) French, english, italian, spanish, german, portuguese, dutch.

Acti 9 | Catalogue 2014 I-15


Time switches IH, IHH

Selection table Mechanical time switches


IH 60mn 1c SRM IH 24h 1c SRM IH 24h 1c ARM IH 24h 2c ARM
P116860

P116861

P116862

P116616
Function
b They operate on hourly, daily or weekly cycle: the same program is repeated hour after hour (IH 60mn), day after day (IH 24h)
or week after week (IH 7j, (IHH 7j)
b The program can be overriden On

Wiring diagrams
P106923

P106881

P106879
1 2 3 L N

1 2 3 L N

Catalogue numbers CCT15338 CCT16364 CCT15365 15337

Technical specifications
Voltage rating (Ue) 230 V AC +10 %, -15%, 230 V AC +10 %, -15%, 110-230 V AC +10 %, -15%, 230 V AC +10 %, -15%,
50 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Consumption 1 VA 2.5 VA 2.5 VA 2.5 VA
Output contact Cos j = 1 10 A 16 A 16 A 16 A
current under Cos j = 0.6 4A 4A 4A 4A
250 VAC
Degree of protection IP20B IP20B IP20B IP20B
Operating temperature -20°C to +55°C -20°C to +55°C -20°C to +55°C -20°C to +55°C
Time accuracy ±1 s per day at 20°C ±1 s per day at 20°C ±1 s per day at 20°C ±1 s per day at 20°C
Saving Lifetime – – 6 years 6 years
of program Back-up time, – – 200 h with 230 V AC 150 h
and time cumulated 100 h with 100 V AC
by lithium mains cut off
battery
Programming Jumpers – – – 4 red + 4 green + 2 white
by: (supplied)
Captive 96 96 96 –
segments

I-16 Acti 9 | Catalogue 2014


IH 24h + 7j 1+1c ARM IH 7j 1c ARM IH24h 1c SRM IH 24h 1c ARM IHH 7j 1c ARM
18 mm 18 mm 18 mm
P111619

P116863

P111614

P111615

P111613
P106879

P106881

P106882

15366 CCT15367 15335 15336 15331

230 V AC +10 %, -15%, 110-230 V AC +10 %, -15%, 230 V AC, ±10 %, 230 V AC, ±10 %, 230 V AC, ±10 %,
50 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
2.5 VA 2.5 VA 2.5 VA 2.5 VA 2.5 VA
16 A 16 A 16 A 16 A 16 A
4A 4A 4A 4A 4A

IP20B IP20B IP20B IP20B IP20B


-20°C to +55°C -20°C to +55°C -10°C to +50°C -10°C to +50°C -10°C to +50°C
±1 s per day at 20°C ±1 s per day at 20°C ±1 s per day at 20°C ±1 s per day at 20°C ±1 s per day at 20°C
6 years 6 years – 10 years 10 years
150 h 200 h with 230 V AC – 100 h 100 h
100 h with 110 V AC

6 yellow (24 h), 12 blue – – – –


+ 2 red (7 days)
– 84 96 96 84 I

Acti 9 | Catalogue 2014 I-17


Time switches IHP, IH, IHH, ITM

Accessories Program Memory Antenna Additional Wall mount


selection jumpers accessory
table
IHP+ programming IHP+ key Cartridge IHP ANT DCF IH jumpers
kit for PC
P93580

P93581

059236N

P151159
Function
Consists of a Saving and duplicating Antenna for IHP DCF They are used to program The 18 mm time
programming device, programs a larger number of switches can be
a memory key, For IHP+ For ITM sequences for: mounted on a wall
a CDROM and a 2 m USB 1c/2c, b IH 24h 2c ARM (15337) by using 15359
cable ICAstro 1c/2c, b IH 24h + 7j 1+1c ARM reference.
IC100kp+ (15366) The protection cover
1c/2c, is sealable.
IHP 1c 18 mm,
IHP+ 1c 18 mm
Mounting
– Located on front face b 5 IHP DCF maximum 1 bag containing: The 15359 accessory
per antenna, maximum b 5 red can be also used to
distance between the IHP b 5 green mount others 18 mm
DCF and the antenna: 200 b 5 white DIN rail devices
m b 5 yellow (for example: timers ,
b Outside the electrical circuit breakers...).
switchboard, outdoors,
under shelter
Catalogue numbers CCT15860 CCT15861 15280 15858 15341 15359

Technical spécifications
Degree of protection – – – IP54 –
Operating temperature – – – -20°C to +70°C –
Overall dimensions – – – 70 x 57 x 92 – See § dimensions
L x W x H (mm)

Specific technical data


IHP+ 1c, IHP+ 2c, IHP DCF
Manual functions Temporary cancellation of programming for holidays, public holidays, etc. by configuration of the 2 dates -
start and end of absence
Simulation of presence thanks to random operation during On periods
Pulse functions Programming of pulses adjustable from 1 to 59 s (pulse takes priority over switching)
Back-lighting of the screen
External input (only for IHP+ 1c, IHP+ 2c)
External inputs for external control 1 input for IHP+ 1c
with a standard switch or a push-button 2 inputs for IHP+ 2c
Voltage rating (Ue) 230 V AC, +10 %, -15 %
Frequency 50/60 Hz
Input current y 1.2 mA
Consumption y 0.3 mW
Cable length y 100 m
Synchronisation on the Frankfurt's DCF 77 radio station signal (only for IHP DCF)
Automatic on commissioning, then at 1 am, 2 am, 3 am and 4 am every day
Manual by pressing the IHP keys or after a "reset"
Displayed on the screen by the letters RC
Programming of pulses adjustable from 1 to 59 s (pulse takes priority over switching)

I-18 Acti 9 | Catalogue 2014


Time switches IHP, IH, IHH, ITM (cont.)
Praticle advices

Programming principle
b For the IHP switches, this consists of memorising the days and times
of the required switching operations.
b For the IH - IHH switches, this is performed by positioning captive segments
or jumpers on a switching dial.
Example
b Controlling an air conditionner in a hairdressing salon:
Monday (1) Tuesday Wednesday Thursday (2) Etc.
On n° 1 08 h 30 08 h 30 08 h 30 Switch on
Off n° 1 12 h 00 12 h 00 Switch off
On n° 2 13 h 30 13 h 30 Switch on
Off n° 2 20 h 00 20 h 00 20 h 00 Switch off
(1) Closed on Mondays
(2) Non-stop

Programming by copying or blocks


Whenever identical switching operations are found at the same times, several days
in the week, this function lets you program these operations once only.
In this case a single switching operation is used. If this function is used wisely,
the number of possible switching operations can be greatly increased.
Example
Monday Tuesday Wednesday Thursday Friday
On n°1 10 h 00 10 h 00 Switch on
Off n°1 18 h 00 18 h 00 18 h 00 Switch off

1 switching
operation 1 switching operation

Number of switching operations


Designation Number of switching operations
IHP 1c 56
IHP + 1c 84
IHP DCF 1c 42
IHP 2c 56
IHP + 2c 84
IHP 1c 18 mm 56
IHP + 1c 18 mm 84
ITM 4C-6E 45 time brackets in weekly time programming, 15 time
brackets in annual time programming and 20 different pulses
in pulse programming
IH 24h 1c ARM 48 On - 48 Off
IH 24h 1c SRM 48 On - 48 Off
IH 60mn 1c SRM 48 On - 48 Off
IH 24h 1c SRM 48 On - 48 Off
IH 24h 1c ARM 48 On - 48 Off
IH 24h 2c ARM 24 On - 24 Off
IH 7j 1c ARM 42 On - 42 Off
IH 24 h + 7j 1+1c ARM 16 On - 16 Off + 7 On - 7 Off

Saving on mains cut off


I
For IHP switches equipped with this function, a lithium battery is used for saving.
The program, date and time are preserved. Switching operations are not performed.

Acti 9 | Catalogue 2014 I-19


Time switches IHP, IH, IHH, ITM (cont.)
Praticle advices

Lets you control starting and stopping of a group 60 min. time programming
of loads according to a cycle that is repeated Example
every 60 minutes.
Controlling automatic watering
On n° 1 2 min. 30 s
Off n° 1 5 min.
On n° 2 25 min.
Off n° 2 37 min. 30 s

Relevant time switches


IH 60mn 1c SRM.

Lets you control starting and stopping of one or 24 h daily programming


two groups of loads according to a daily cycle that Example
is repeated, in identical manner, every day of the
b Controlling a door of a block of flats:
week. v from 8 am to 7.30 pm: contact on "On", free access,
v from 7.30 pm to 8 am the next day: contact on "Off", access by confidential code
every day of the week:
From Monday to Sunday
On n° 1 8 am
Off n° 1 7.30 pm

Relevant time switches


b IH 24h 1c SRM/ARM.
b IH 24h 2c ARM.
b IHP 1c 18 mm.
b IHP + 1c 18 mm.
b IHP DCF 1c.
b IHP 1c, IHP + 1c.
b IHP 2c, IHP + 2c.
b ITM 4C-6E.

Lets you control starting and stopping of one 7 days weekly programming
to 4 groups of loads according to a weekly cycle, Example
that can be different each day, repeated each
b Controlling an air conditionner in a hairdressing salon:
week.
Monday Tuesday Wednesday Thursday Friday Saturday Sunday
On n° 1 09 h 00 09 h 00 09 h 00
Off n° 1 12 h 00 12 h 00
On n° 2 14 h 00 14 h 00
Off n° 2 20 h 00 20 h 00 20 h 00
On n° 3 8 h 30 8 h 30
Off n° 3 12 h 30 12 h 30
On n° 4 14 h 30 14 h 30
Off n° 4 21 h 00 21 h 00

Relevant time switches


b IH 7j 1c ARM.
b IHP 1c, IHP + 1c.
b IHP 2c, IHP + 2c.
b IHP 1c 18 mm.
b IHP + 1c 18 mm.
b IHP DCF 1c.
b ITM 4C-6E.

I-20 Acti 9 | Catalogue 2014


Lets you control by pulses (adjustable from Pulse programming
1 to 59 s) one to four groups of loads (pulse relays, Example
bells, etc.).
b Automatic controlling of bells, lighting and distribution of food: bells sounding
the resumption and finish of work (channel 1), lighting of premises (channel 2),
feeding fish in the aquarium (channel 3):
Monday Tuesday Wednesday Thursday Friday Saturday Sunday
Channel 1: bell (20 s pulse order)
On 08 h 00 08 h 00 08 h 00 08 h 00 07 h 00 09 h 00 –
Duration 20 s 20 s 20 s 20 s 20 s 20 s –
On 12 h 00 12 h 00 12 h 00 12 h 00 11 h 00 13 h 00 –
Duration 20 s 20 s 20 s 20 s 20 s 20 s –
On 14 h 00 14 h 00 14 h 00 14 h 00 13 h 00 – –
Duration 20 s 20 s 20 s 20 s 20 s – –
On 18 h 00 18 h 00 18 h 00 18 h 00 16 h 00 – –
Duration 20 s 20 s 20 s 20 s 20 s – –
Channel 2: lighting (latched order)
On 07 h 30 07 h 30 07 h 30 07 h 30 06 h 30 08 h 30 –
Off 18 h 30 18 h 30 18 h 30 18 h 30 17 h 00 13 h 30 –
Channel 3: aquarium (15 s pulse order)
On 10 h 00 – 10 h 00 – 10 h 00 – 10 h 00
Duration 15 s – 15 s – 15 s – 15 s

Programming
b Programming of a pulse takes up 2 memory spaces.
b Combination of the two order types (pulse and latched) is possible on the same
channel.

Relevant time switches


b IHP + 1c.
b IHP + 1c 18 mm.
b IHP DCF 1c.
b IHP + 2c.
b ITM 4C-6E.

Lets you create special programs for dated days. Programming special days.
Example
b Controlling lighting and heating in a school:
v basic programming: program lighting (channel 1) and heating (channel 2):
Monday Tuesday Wednesday Thursday Friday Saturday Sunday
Channel 1: lighting
On 07 h 00 07 h 00 07 h 00 07 h 00 07 h 00 – –
Off 20 h 00 20 h 00 16 h 00 20 h 00 16 h 00 – –
Channel 2: heating
On 06 h 00 06 h 00 06 h 00 06 h 00 06 h 00 – –
Off 18 h 00 18 h 00 12 h 00 18 h 00 12 h 00 – –
v dated programming: periods of non-operation, school holidays, etc.
Just memorise an Off at the start and another Off at the end of each period
of absence:
Holidays
Winter Spring Summer Autumn End of year
I
Channel 1: lighting
Off Date 20 feb. 17-apr 07-july 23 oct. 18 dec.
Time 12 h 00 17 h 00 12 h 00 17 h 00 12 h 00
Off Date 08-march 03-may 9 sept. 2 nov. 4 jan.
Time 01 h 00 01 h 00 01 h 00 01 h 00 01 h 00
Channel 2: heating
Off Date 20 feb. 17-apr 23 oct. 18 dec.
Time 12 h 00 17 h 00 17 h 00 12 h 00
Off Date 08-march 03-may 2 nov. 4 jan.
Time 01 h 00 01 h 00 01 h 00 01 h 00

Relevant time switches


b ITM 4C-6E.

Acti 9 | Catalogue 2014 I-21


Time switches IHP, IH, IHH, ITM (cont.)

Connection
DB123947

Type Tightening torque Copper cables


Rigid Flexible or with ferrule
8 mm
5 mm

DB122945

DB122946
IHP 1c, 2c, +1c, +2c 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
PZ1
IHP 18 mm 1c, +1c 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
IHP DCF 1.2 N.m y 6 mm2 y 6 mm2
IH 60mn 1c SRM 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
24h 1c SRM, ARM 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
24h 2c ARM 1.2 N.m y 6 mm2 y 6 mm2
7j 1c ARM 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
24h + 7j 1+1c ARM 1.2 N.m y 6 mm2 y 6 mm2
IH 18 mm 24h 1c SRM/ ARM 1.2 N.m y 6 mm2 y 6 mm2
IHH 18 mm 7j 1c ARM 1.2 N.m y 6 mm2 y 6 mm2
ITM 4c-6E 1.2 N.m y 6 mm2 y 6 mm2
IHP 1c/2c, IHP+ 1c/2c are mechanical compatible with electrical distribution comb busbar.

Weight (g)
Time switches
IHP 1c / 2c 170/ 205
IHP+ 1c / 2c 190/ 211
IHP 18 mm 1c / +1c 90
IHP DCF 244
IH 54 mm 60mn 1c SRM 208
24h 1c SRM/ARM 212 / 119
24h 2c ARM 216
7j 1c ARM 119
24h + 7j 1+1c ARM 223
IH 18 mm 24h 1c SRM / ARM 97
IHH 18 mm 7j 1c ARM 101
ITM 4c-6E 415
Accessories
Programming kit for PC 150
ANT DCF 168

I-22 Acti 9 | Catalogue 2014


Dimensions (mm)
IHP programmable time switches
6 60 6 60 5.5 60
P106982

44 44 18 44
45
19

82/85* 85 45 82 45 90 45 69

5P: IHP DCF 5 P: IHP 1C/2C/+1C/+2C 5P : IHP DCF 2P (18 mm)


*5P: IHP 1C/2C/+1C/+2C IHP 1C /+

IH, IHH time switches


6 60 6 60 66
DB124561

28
18 44 54 38 22 54 22
16

90 45 82 45 90 45

2P (18 mm) 6P (IH 24h 2c ARM, 6P (IH 60m 1c RM, IH 24h 1c RM ARM
IH 24h +7j 1+1c ARM) IH 7j 1c ARM)

ANT DCF antenna ITM 4C-6E


56 60
DB124563

DB124564

70 54 31
90 6

80 84
93 93
90 90 45

6.5
32.5
2xø4

Wall mount accessory


34
56
18
15359_dimensions

30 Ø8
Ø4 10

45
7
128 113 Ø8 40
I
Ø4

Acti 9 | Catalogue 2014 I-23


Timers MIN, MINs, MINp, MINt

Timers Electromechanical timer

P111648

MIN
Adjustable time delay from 1 to 7 min.

Silent electronic timers


P111642

P111643

P111644

MINs MINp MINt


Adjustable time delay Adjustable time delay Adjustable time delay from 0.5 to 20 min.
from 0.5 to 20 min. from 0.5 to 20 min. with switch-off warning and impulse
with switch-off warning. relay function.

I-24 Acti 9 | Catalogue 2014


Timers MIN, MINs, MINp, MINt (cont.)

Selection table
MIN MINs
Type Electromechanical timer Silent electronic timer

P111648

P111642
Function
These timers allow closing and then opening of a contact in a determined time
Control circuit: connected standard or luminous push-buttons. Timer inoperative via self-protection if consumption
above 50 mA maximum
Wiring diagrams
P106867

P106869
4 wires 4 wires

L 3 L 3

N 4 N 4
R or R or
3 wires 3 wires

Mounting
Two operating modes triggered by switch on front face: Two operating modes triggered by switch on front face:
b Automatic mode: b Timer mode: time delay adjustable from 0.5 to 20 min.
v operation in timing mode b Permanent mode: constant lighting
v time delay adjustable from 1 to 7 min.
v setting in steps of 15 s using knob
v pressing a push-button renews the time delay
b Manual override mode: constant lighting
b Specific shield for terminal blocks insulation
(Cat. no. 15359)

Catalogue numbers 15363 CCT15232

Technical specifications
Voltage rating (Ue) (+10 %, -15 %) 230 V AC, 50 Hz 230 V AC, 50/60 Hz
Consumption 1 VA < 6 VA
Output contact current Cos j = 1 16 A 16 A
Degree of protection
Operating temperature
IP20B
-10°C to +50°C
IP20B
-10°C to +50°C
I
Width (9 mm modules) 2 2
Consumption of connected luminous 50 mA maxi 150 mA maxi
push-buttons
Adjustable time delay 1 to 7 min. 0.5 to 20 min.
Long time delay – –
Insulation class – Class II
1 screw connection per pole for cables b b
up to 6 mm2
Selection of the type of connection (3 or 4 wires) Selector switch Automatic
Mechanical compatibility with electrical – b
distribution comb busbar
Switch-off warning function – –
Impulse relay function – –

Acti 9 | Catalogue 2014 I-25


Timers MIN, MINs, MINp, MINt (cont.)

MINp MINt
Silent electronic timer
P111643

P111644
The MINp timer allows closing and then opening of a contact in a determined time, The MINt timer is the same as MINp with an "impulse relay" additional
and it also provides warning that the lighting is about to be switched off by flickering function
of the lamplight (switch-off warning)
P106871
P106871

4 wires 4 wires

L 3 L 3

N 4 N 4
R or R or
3 wires 3 wires

b Time delay adjustable from 0.5 to 20 min


b Three operating modes triggered by switch on front face:
v timer mode with "switch-off warning" function built into the device. The lamp blinks 40 and 30 s before the end of the time delay
v timer mode mode without "switch-off warning" function
v permanent mode : constant lighting
b Timer mode operation: b Timer mode operation:
v pressing a push-button for longer than 2 s: lighting will last for 1h. Pressing again v pressing a push-button for longer than 2 s: lighting will last for 1h.
a push-button for less than 2 s relaunch the time delay of 1h and pressing again Pressing again a push-button for less than 2 s relaunch the time delay
a push-button for more than 2 s switches off the light of 1h and pressing again a push-button for more than 2 s switches off the light
v pressing a push-button for less than 2 s launch the pre-set time delay, pressing v pressing a push-button for less than 2 s launch the pre-set time delay,
again a push-button for less than 2 s relaunch the pre-set time delay pressing again a push-button for less than 2 s, switches off the light
(impulse relay mode)
CCT15233 CCT15234

230 V AC, 50/60 Hz 230 V AC, 50/60 Hz


< 6 VA < 6 VA
16 A 16 A
IP20B IP20B
-25°C to +50°C -25°C to +50°C
2 2
150 mA maxi 150 mA maxi

0.5 to 20 min. 0.5 to 20 min.


1h 1h
Class II Class II
b b

Automatic Automatic
b b

b b
– b

I-26 Acti 9 | Catalogue 2014


Timers MIN, MINs, MINp, MINt (cont.)

Load table
Products MIN MINs MINp, MINt
Type of lighting Maximum power
230 V incandescent and halogen lamps 2300 W 2300 W 3600 W
Non-corrected / serial-corrected / dual mounted 2300 VA 2300 VA 3600 VA (1)
fluorescent tubes with conventional ballast
Fluocompact lamps with conventional ballast 2000 VA 1500 VA 1500 VA (1)
Parallel-corrected fluorescent tubes 1300 VA (70 F) 400 VA (42 μF) 1200 VA (120 μF) (1)
with conventional ballast
Fluorescent tubes with electronic ballast 300 VA 300 VA 1000 VA
Fluocompact lamps with electronic ballast 9 x 7 W, 6 x 11 W, 5 x 15 W, 9 x 7 W, 7 x 11 W, 7 x 15 W, 34 x 7 W, 27 x 11 W,
5 x 20 W 7 x 20 W, 7 x 23 W 24 x 15 W, 22 x 23 W
(1)
The "switch-off warning" function is not available for these types of loads.

Connection
Type Tightening torque Copper cables
DB123947

Rigid Flexible or with ferrule


8 mm

DB122945

DB123553
5 mm

MIN, MINs, MINp, MINt 1.2 N.m y 6 mm2 y 6 mm2


PZ1

Weight (g)
Time switches
MIN 84
MINs 75
MINp 103
MINt 76

Dimensions (mm)
5 63
DB124571

18 38

83 83 45

MIN

6 60 I
DB124572

44
18 24

85 89 45 72

MINs, MINp, MINt

Acti 9 | Catalogue 2014 I-27


Dimmers STD and SCU range
STD400RC/RL-DIN & SAE
STD1000RL-DIN & SAE
SCU10-DIN & SAE

STD STD

P112245

P112246
b The STD dimmers modulate incandescent
halogen, lighting brightness and motors for unit
powers from 40 to 1000 W from one or more
switch-on points.
b They can be controlled either with the local
control push-button placed on front panel or with
auxiliary push-buttons.
b They have soft-On / soft-Off, light level memory
and minimum level setting features.
STD400RC/RL-DIN STD400RC/RL-SAE b They are available in 2 different types:
v DIN type (STD400RC/RL-DIN,
P112248

STD1000RL-DIN) supplied without digital inputs,


v SAE type (STD400RC/RL-SAE,
STD1000RL-SAE) supplied with 4 digital inputs.

STD1000RL-SAE

SCU
SCU
P112221-35

b The SCU dimmers modulate fluorescent lighting


brightness for unit powers from 40 to 1500 W from
one or more switch-on points.
b They can be controlled either with the local
control push-button placed on front panel or with
auxiliary push-buttons.
b They have soft-On / soft-Off, light level memory
and minimum level setting features.
b They are available in 2 different types:
SCU10-SAE v DIN type (SCU10-DIN) supplied without digital
inputs,
v SAE type (SCU10-SAE) supplied with 4 digital
inputs.

I-28 Acti 9 | Catalogue 2014


Dimmers STD and SCU range (cont.)
STD400RC/RL-DIN & SAE
STD1000RL-DIN & SAE
SCU10-DIN & SAE
Selection table
STD
STD400RC/RL-DIN STD400RC/RL-SAE STD1000RL-DIN STD1000RL-SAE
Type 400 W 1000 W
P112245

P112246

P112247

P112248
Wiring diagrams
L L L
P106846

N N N
(1) (1)

N L N L N L N L N L

STD400RC/RL-DIN STD400RC/RL-SAE STD400RC/RL-SAE STD400RC/RL-SAE STD400RC/RL-SAE


STD1000RL-DIN STD1000RL-SAE STD1000RL-SAE STD1000RL-SAE STD1000RL-SAE

12-30 V AC/DC 12-30 V AC/DC 12-30 V AC/DC 12-30 V AC/DC


0V 0V 0V 0V
1 2 3 4 0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0

(2)

12-30 V AC/DC 12-30 V AC/DC

Mounting
With SAE types, it is possible to control a maximum of 20 dimmers combining STD400RC/RL-SAE and STD1000RL-SAE,
with only one push-button via the 4 digital inputs
Catalogue numbers CCTDD20001 CCTDD20002 CCTDD20003 CCTDD20004

Technical specifications
Voltage rating (Ue) 230 V AC ± 10 %, 50 Hz
Consumption 0.8 VA
Power loss 3W
Current sink -
for 1-10 V output
Local push-button Short push for On/Off control, long push for dimming
Auxiliary push-button Short push for On/Off control, long push for dimming:
input b up to 25 parallel connected auxiliary push-buttons without indication lamps
b up to 5 parallel connected auxiliary push-buttons with indication lamps

I
b max wire length 50 m
The minimum light b
level setting
is adjustable
Indication blue LED Illuminates during the on-state. The LED is blinking in error mode
(built in the local
push-button)
Degree of protection IP20
Operating temperature 0°C to +40°C, 40°C to +70°C with - 6 W /°C de-rating
Storage temperature 0°C to +60°C
Width (module of 9 mm) 4 4 8 8
Protections, fuses b Electronic overload, overvoltage and over temperature protection
b Single shot thermal fuse
Standards According to EN 60669-2-1
Directives According to CE, EMC 89/336/EEC and LVD 73/73/23/EEC
(1) Use of maximum 25 push-buttons without indication lamp and 5 push-buttons with indication lamp, connected in parallel.
(2) Use of maximum 25 push-buttons without indication lamp, connected in parallel, only for STD400RC/RL-SAE and STD1000RL-SAE.

Acti 9 | Catalogue 2014 I-29


Dimmers STD and SCU range (cont.)
STD400RC/RL-DIN & SAE
STD1000RL-DIN & SAE
SCU10-DIN & SAE

SCU
SCU10-DIN SCU10-SAE
1 - 10 V
P112250

L L L P112221
P106847

N N N
(1) (1) (1) (1) (1)

N L N L N L N L N L

SCU10-DIN SCU10-SAE SCU10-SAE SCU10-SAE SCU10-SAE

1 - 10 V 12-30 V AC/DC 1 - 10 V 12-30 V AC/DC 1 - 10 V 12-30 V AC/DC 1 - 10 V 12-30 V AC/DC 1 - 10 V


0V 0V 0V 0V
+ - 1 2 3 4 0 + - 1 2 3 4 0 + - 1 2 3 4 0 + - 1 2 3 4 0 + -

+ - L N + - L N + - L N + - L N + - L N
1- 10 V 1- 10 V 1- 10 V 1- 10 V 1- 10 V
(3)

12-30 V AC/DC 12-30 V AC/DC

With SAE types, it is possible to control a maximum of 20 dimmers combining STD400RC/RL-SAE, STD1000RL-SAE and SCU10-SAE with only one push-button
via the 4 digital inputs
CCTDD20011 CCTDD20012

230 V AC ± 10 %, 50 Hz
0.8 VA
3W
0.2- 100 mA

Short push for On/Off control, long push for dimming


Short push for On/Off control, long push for dimming:
b up to 25 parallel connected auxiliary push-buttons without indication lamps
b up to 5 parallel connected auxiliary push-buttons with indication lamps
b max wire length 50 m
b

Illuminates during the on-state. The LED is blinking in error mode

IP20
0°C to +40°C, 40°C to +70°C with - 6 W /°C de-rating
0°C to +60°C
8 8
b Electronic overload, overvoltage and over temperature protection
b Single shot thermal fuse
According to EN 60669-2-1
According to CE, EMC 89/336/EEC and LVD 73/73/23/EEC
(3) Use of maximum 25 push-buttons without indication lamp, connected in parallel, only for SCU10-SAE

I-30 Acti 9 | Catalogue 2014


Dimmers STD and SCU range (cont.)
STD400RC/RL-DIN & SAE
STD1000RL-DIN & SAE
SCU10-DIN & SAE
Specific technical data
SAE types
Input voltage 12- 30 V AC/DC
The STD400RC/RL-SAE, Input 1 On/Off and dimming up/down or only On and
STD1000RL-SAE and dimming up (depends on function mode)
SCU10-SAE dimmers are Input 2 Off and dimming down or only Off (depends on
supplied function mode)
with 4 digital inputs Input 3 Adjustable lighting level memory 1 (50 % default)
Input 4 Adjustable lighting level memory 2 (100 % default)
Max wire length 50 m
Up to 25 push-buttons per input. No push-button with indication lamp
STD400RC/RL-DIN and STD400RC/RL-SAE dimmers are power regulators designed for all
dimmable load types. Dimmers have automatic load type detection and the load regulation
method is adjusted to fit the load

Operation modes for SAE types


b STD400RC/RL-SAE, STD1000RL-SAE and SCU10-SAE dimmers have 2
different operation modes (A and B) using auxiliary push-buttons connected on
digital inputs (1, 2, 3 and 4 terminals).
b Modes A and B can be changed by pushing the digital inputs 3 and 4
simultaneously for 10 s. After the mode is changed the load and the LED start to blink
as long as the inputs are pushed.
b In the mode A, the input 1 dims the lights on with a short push and up with a long
push and turns light off with a short push and dims the light down with a long push.
The direction is changed every time the input 1 is released. The input 2 dims the
lights always off.
b In the mode B, the input 1 dims lights only up with a long push and turns lights on
with a short push. The input 2 dims the lights only down with a long push and turns
lights off with a short push.
b Inputs 3 and 4 are for memory places for light levels. The light level is called with a
short push and set into the memory with a long push of 3 s.

Common technical data


Common operation mode for SAE & DIN types
b The dimmer is turned On/Off by shortly pushing the front panel push-button.
This push-button lights blue when the dimmer is On.
b The light level is controlled by keeping the front panel push-button pushed until
wanted level has been reached.
b The direction of dimming (up/down) is changed every time the front panel
push-button is released.
b The dimmer has memory function which stores the light level before
Off-command. When the dimmer is turned back On, the light level is the same as it
was before Off-command.
b Auxiliary push-buttons connected on terminal have the same functionality as
the push-button on the front panel of the dimmer.

Load table
STD400RC/RL-DIN, STD400RC/RL-SAE
230 V incandescent and halogen lamps 40 - 400 W
Low voltage halogen lamps with electronic transformer 40 - 400 W

I
Low voltage halogen lamps with conventional transformer 40 - 300 W
Motors (fans, ventilators...) 40 - 200 W
STD1000RL-DIN, STD1000RL-SAE
230 V incandescent and halogen lamps 60 - 1000 W
Low voltage halogen lamps with electronic transformer 60 - 1000 W
Low voltage halogen lamps with conventional transformer 60 - 1000 W
Motors (fans, ventilators...) 60 - 600 W
SCU10-DIN, SCU10-SAE
Mono fluorescent tubes with electronic ballast (dia.26 mm) 50 x 18 W, 40 x 36 W,
25 x 58 W
Duo fluorescent tubes with electronic ballast (dia.26 mm) 40 x 18 W, 20 x 36 W,
12 x 58 W
Fluocompact lamps with electronic ballast 50 max. up to 1500 W

Acti 9 | Catalogue 2014 I-31


Dimmers STD and SCU range (cont.)
STD400RC/RL-DIN & SAE
STD1000RL-DIN & SAE
SCU10-DIN & SAE

Connection
Type Tightening Copper cables
P106928

torque Rigid Flexible or with ferrule


8 mm

DB122945

DB123553
3 mm

STD and SCU (top connection) 0.5 N.m < 4mm2 < 4 mm2
STD and SCU (bottom connection) 0.5 N.m < 2.5 mm2 < 2.5 mm2

Weight (g)
Dimmers
STD400RC/RL-DIN 80
STD400RC/RL-SAE 90
STD1000RL-DIN 120
STD1000RL-SAE, SCU10 130

Dimensions (mm)
P106845

85 45 68

6
36 72 56

STD400RC/RL STD1000RL
SCU10

I-32 Acti 9 | Catalogue 2014


Thermostats TH4, TH7 and THP1, THP2

Thermostats TH4

P123732
For individual and multifamily housing, tertiary
premises, TH4 thermostat monitors and regulates
ambient temperature from +8°C to +26°C
according to 3 temperature set points:
b comfort: while the promises are occupied
b reduced: while the premises are unoccupied
b above freezing: for a prolonged period of
non-occupancy.

TH7
P123731

For industrial premises stretching from cold


storage to ovens, TH7 thermostat monitors and
regulates temperature from -40°C to +80°C
with a wide setting range.
It can also be used for frost protections at home.

Programmable
THP1 and THP2
P126317

thermostats Programmable thermostats control the operating


periods of all heating types by monitoring and
regulating ambient temperature between 5°C and
30°C, using a programme pre-set by the user and
memorised:
b THP1: 1 zone,
b THP2: 2 zones.
P126318

Acti 9 | Catalogue 2014 I-33


Thermostats TH4, TH7 and THP1, THP2
(cont.)

Selection table Thermostats


TH4 TH7
Type

P123732

P123731
Function
For individual and multifamily housing, tertiary premises, TH4 b For industrial premises stretching from cold
thermostat monitors and regulates ambient temperature from storage to ovens, TH7 thermostat monitors and
+8°C to +26°C according to 3 temperature set points: regulates temperature from -40°C to +80°C with
b comfort: while the promises are occupied a wide setting range
b reduced: while the premises are unoccupied b It can also be used for frost protections
b above freezing: for a prolonged period of non-occupancy at home

Wiring diagrams
P106772

P106773

Load Load

Mounting
Delivered with CCT15846 ambient temperature probe Delivered without probe
Catalogue numbers CCT15841 CCT15840

Technical specifications
Voltage rating (Ue) 230 V AC, ± 10 %, 50/60 Hz

Consumption < 4 VA
Output contact current Cos j = 1 16 A
(250 V AC) Cos j = 0.6 3A
Power reserve –
Time base –
Difference between tripping and activation ±0.2°C
Degree of protection IP20
Operating temperature -10°C to +55°C
Storage temperature -20°C to +60°C
Set Point accuracy 1°C
Humidity 15-95 % RH (no condensation)
Width (module of 9 mm) 5
Color White RAL 9003
Protections, fuses Internal over voltage protection against surges, internal over temperature protection
Compliance with Isolating requirements, EN 60730-2-9
Community Directives E.M.C. guidelines and
Safety guidelines
RoHS and EU-directive 2002/95/EC (RoHS)
environmental issues WEEE-directive 2002/96/EC (recycling)
REACH Regulation (EC) No 1907/2006

I-34 Acti 9 | Catalogue 2014


Programmable thermostats
THP1 THP2
P126317

P126318
b The THP1 and THP2 programmable thermostats control the operating periods of all heating types by monitoring and regulating ambient temperature between
5°C and 30°C, using a programme pre-set by the user and memorised
b The THP1 and THP2 monitors and regulates temperature in a room by comparing the value of the temperature measured by the ambient temperature probe
with the value of the setpoint displayed on its front face according to 3 operating modes:
v comfort: 5°C to 30°C while the premises are occupied
v reduced: 5°C to 26°C while the premises are unoccupied
v above freezing: the temperature in the premises is maintained at approximately 6°C
b The THP1 and THP2, can control the following loads:
v convectors
v a burner
v a "hot air" heating system
v heating valves: hydraulic, electromagnetic or electrothermal
P106851

P106852

Above Comfort Ambient Zone 1 Zone 2


freezing temperature Above Comfort Ambient
probe freezing temperature
probe

L 1 3 5 7 13 15
L 1 3 5 7 9 11 13 15
THP1

: THP2

: Zone 1

Zone 2
N 10 12 14 16
N 2 4 6 10 12 14 16

230 V Load control


230 V Zone 1 Zone 2
Load control

Delivered with 1 non-adjustable ambient temperature probe Delivered with -2 non-adjustable ambient temperature probes
15833 15834

230 V AC

1 VA

I
5A
1A
6 years
Quartz
±0.2°C
IP20.1
-5°C to +55°C
-25°C to +70 °C

30-50 % RH (no condensation)
10
White RAL 9003

NF C 47-121
EN 60730-1: 1991




Acti 9 | Catalogue 2014 I-35
Thermostats TH4, TH7 and THP1, THP2
(cont.)

Selection table TH4, TH7 temperature probes


Accessories Floor temperature probe Ambient temperature probe
(with 1.5 m cable) (with 1.5 m cable)
Type
P123733

P123734
Installation
P106853

P106854

Mounting
This probe must be placed: This probe must be fixed 1.50 m above the floor, away from drafts
b in a Ø 9 mm tube, embedded in the slab in the middle and sources of heat (sun's rays, radiators, machines, etc.)
of a turn
b one of the ends must run out of a distribution box sealed in
the nearest wall (to simplify probe installation or replacement)
Catalogue numbers CCT15845 CCT15846

Note: for all probes, do not run connecting cables alongside power cables.
TH4 and TH7 probes cables can be extended up to 70 m by using 6/10th telephone cable or up to 150 m by using shielded copper cable.
THP1 and THP2 probes cables can be extended up to 50 m by using 6/10th telephone cable or shielded copper cable.

Specific technical data


TH4
Settings Comfort From +8°C to +26°C
Reduced From 0°C to 10°C below the selected "comfort" temperature set point: control (manual or automatic)
by external dry contact
Above Maintains room temperature according to a factory adjusted temperature set point of +5°C: control
freezing (manual or automatic) by external dry contact
Three indicator lights Green Above freezing operation
visualise Yellow Reduced operation
Red Relay: ON
Delivered with ambient temperature NTC 10 kΩ (25°C) can be extended up to 150 m with shieded copper cable and up to 70 m with telephone cable
probe (CCT15846)
Note: however, the set point selected never can’t be less than +8°C. Eg. If the reduced set point is selected with a 12°C set point temperature and a 10°C reduction
temperature, the operative set point will not be +2°C (12-10) but rather +8°C (+5°C only if the "above freezing" input is closed/active).
TH7
Temperature set Range 6 fixed positions: -40°C, -20°C, 0°C, +20°C, +40°C and +60°C
point settings (1) Adjustements From 0°C to 20°C above the selected fixed position
Indicator light Red Relay: ON
Delivered without probe
(1) For example: if "range" is on -40°C, setting is possible between -40°C and -20°C.

I-36 Acti 9 | Catalogue 2014


THP1,THP2 temperature probes
Outside temperature probe Collar temperature probe Ambient temperature probes
(with 2 m cable) (with 1.5 m cable)
Non-adjustable probe ± 3 °C adjustable probe Spare battery

049540r
P123735

P123736

P126320

P126321
P106855

This probe must be fixed away from: This probe must be fixed on the hot water These probes must be fixed 1.50 m above the floor,
b the sun preferably facing north outgoing pipe (min. ø 21 mm, max. ø 90 mm) away from drafts and sources of heat
b all heat sources (chimney, etc.) approximately 1.50 m from the boiler. (sun's rays, radiators, machines, etc.)

CCT15847 CCT15848 15835 15836 16358

THP1, THP2
Display By liquid crystal display of hour, minutes, day of the week and of contact status
Indicator lights: 5 LEDs for 1 zone and 10 for 2 zones displaying:
b the automatic, comfort and reduced operating modes (yellow)
b the above freezing operating mode (green)
b the ON position of the output contact(s) (red)
Choosing the operating mode By local pushbutton: automatic, reduced, comfort, above freezing
By external remote contact overriding the local push-button

I
The comfort operating mode overrides the above freezing mode
Programming Minimum programming time between 2 switching operations: 1 minute
Memory:
b THP1: up to 42 switching operations
b THP2: up to 168 switching operations
Programming 24 h / 7 days with:
b possible anticipation of switching
b deletion of a switching operation in order to modify
or cancel a sequence
Changeover to "summer-winter" time in a single operation

Acti 9 | Catalogue 2014 I-37


Thermostats TH4, TH7 and THP1, THP2
(cont.)
Practical advice

TH4
P106774

4 5 6

4 2
1
3 7
8
9
3 Front face (see Fig. 1)
0 10
2 1 Above freezing mode indicator.
1
14 16 18 20
12 22
2 Reduced mode indicator.
5 10
8
24
26 3 Relay.
T/°C
4 Reduced threshold adjustment (reduction of temperature with respect to
the setpoint).
Fig. 1. 5 Temperature threshold adjustment.

TH7
P106775

10

2 5 15 3 Front face (see Fig. 2)


0 20
réglage/adjustment 1 Temperature range setting (6 ranges).
-40
2 Temperature fine adjustement.
1
-20
0

+60
+20
+40 3 Relay indicator.
plage/range

Fig. 2.
THP1
Front face (see Fig. 3)
1 Days indication: cursor on 1 = Monday, on 2 = Tuesday, etc.
P106885

2 Hours and minutes indication.


3 Stopping during holiday periods (holiday override mode).
4 Visualisation of switching status:
ON: comfort
OFF: reduced
5 Yellow indicator light: "Auto" position.
6 Yellow indicator light: "comfort" position.
7 Yellow indicator light: "reduced" position.
8 Green indicator light: "above freezing" position.
9 Red indicator light: output contact status.
19 Button for setting the "comfort" operating mode.
11 Pushbutton for selecting the operating mode for zone 1.
12 Button for setting the "reduced" operating mode.
13 Key for anticipation of switching and programming over 7 days.
14 Key for scrolling the switching and memorisation operations.
Fig. 3. 15 Function key for time and day updating and return to the time display.
16 Minutes setting key.
17 Days setting key.
18 Hours setting key.
P106886

19 Manual slot.

THP1 programming
A programmable clock, built into the THP1, is used for programming (see Fig. 4).
b The various operations for:
Fig. 4. v updating time and day,
v introduction of the programme, are the same as those used to programme the IHP
24 hours and 7 days.
b Programming possibilities:
v 24 hours and 7 days: a separate programme for each day of the week,
v up to 42 switching operations memorised,
v the same switching operation used over several days only counts as one
switching operation,
v power reserve: 6 years.
Example
b Programming:
v temperature thresholds: "comfort" 19°C and "reduced" 16°C,
v presence from 6 a.m. to 8 a.m. and from 6 p.m. to 11 p.m.:
"comfort" heating, temperature of 19°C,
v absence (from 8 a.m. to 6 p.m.) and nighttime (from 11 p.m. to 6 a.m.):
"reduced" heating, temperature of 16°C.

I-38 Acti 9 | Catalogue 2014


230 V Local control
DB121125

L
The operating mode pushbutton (11) is used to select the operating mode and to
N
light up the relevant indicator lights in turn:
2A Auto (indicator light 5)
Above Comfort
Operation takes place according to a pre-set programme (see § on "programming").
freezing Zone 1 b Temperature is regulated with respect to the following temperature thresholds:
v comfort (ON symbol visible) which is set using the button (10),
v reduced (OFF symbol visible) which is set using the button (12).
Comfort (indicator light 6)
The ON symbol is visible.
b Indicator light ON: temperature is regulated only with respect to the "comfort"
temperature threshold (setting button 10).
b Flashing indicator light (see § on "remote control").
Reduced (indicator light 7)
Temperature is regulated only with respect to the "reduced" temperature threshold
(setting button 12). The OFF symbol is visible.
Above freezing (indicator light 8)
b Indicator light ON: temperature is regulated only with respect to the 6.5°C
temperature threshold pre-set in the factory.
b Flashing indicator light (see § on "remote control").
Tempo
probe
Remote control
This operating mode corresponds to the closing of a contact external to the THP
Convectors control (e.g. switch or TRC).
Burner control Closing a comfort operation contact
(Red indicator light (6) flashing on the THP). Once closed, temperature is only
Hot air heating control regulated with respect to the "comfort" temperature threshold.
Load Hydraulic heating valve This external contact (terminals 5 and 7) takes priority over:
control b The local controls ("Auto", "comfort", "reduced", "above freezing").
Fig. 5. THP1 connection example. b The external "above freezing" contact.
Closing an above freezing operation contact
(Green indicator light (8) flashing on the THP). Once closed, temperature is only
regulated with respect to the "above freezing" temperature threshold.
This external contact (terminals 1 and 3) takes priority over local controls
("Auto", "comfort", "reduced", "above freezing").

THP2
DB121146

Front face (see Fig. 6)


1 Days indication: cursor on 1 = Monday, on 2 = Tuesday, etc.
2 Hours and minutes indication.
3 Stopping during holiday periods (holiday override).
4 Visualisation of switching status.
Comfort Reduced
Zone 1 C1 ON OFF
Zone 2 C2 ON OFF
5 Yellow indicator light: "Auto" position.
6 Yellow indicator light: "comfort" position.
7 Yellow indicator light: "reduced" position.
8 Green indicator light: "above freezing" position. I
9 Red indicator light: output contact status.
Fig. 6. 19 Button for setting the "comfort" operating mode.
11 Pushbutton for selecting the operating mode for the zone.
12 Button for setting the "reduced" operating mode.
13 Zone 2 selection key.
14 Zone 1 selection key.
15 Key for scrolling switching and memorisation operations.
16 Function key for updating time and day and return to the time display.
17 Minutes setting key.
18 Days setting key.
19 Hours setting key.
29 Manual slot.

Acti 9 | Catalogue 2014 I-39


Thermostats TH4, TH7 and THP1, THP2
(cont.)
Practical advice

L 230 V THP2 programming


DB121126

N b Programming is carried out by a 2 channel, IHP 24 hours and 7 days


programmable time switch, built into the THP2.
2A b Programming possibilities:
Above Zone 1 v 24 hours and 7 days: a separate programme for each day of the week,
freezing Comfort Zone 2 v 24 switching operations memorised, to be divided up over the 2 zones,
v the same switching operation, used over several days, only counts for the same
operation,
v power reserve: 6 years.

Load Zone 1 Zone 2 Load

Convectors Burner Hot air Hydraulic


control control heating heating valve
control control
Fig. 7. THP2 connection example.

Connection
Type Tightening torque Copper cables
DB123132

Rigid Flexible or with ferrule


8 mm
5 mm
DB122945

DB123553

THP1, THP2 1.2 N.m 4 mm2 4 mm2


PZ1 TH4, TH7 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2

Weight (g)
Thermostats
TH4, TH7 125
TH4 with probe 205
Programmable thermostats
THP1 489
THP2 570

I-40 Acti 9 | Catalogue 2014


Dimensions (mm)
60

P106777
45 5 44

45 85

TH4 and TH7 thermostats


DB121130 60
90 5 44

81 45 81

THP1 and THP2 programmable thermostats

80 25 70 27
P106778

094-0400-B

80 46 70 70

R 16
TH4, TH7, ambient temperature probe THP1, THP2, ambient temperature probes

094-0400

Acti 9 | Catalogue 2014 I-41


Monitoring Relays
Control
Remote control

Time delay relays are used in service


sector and industrial buildings for small

PB107133-35

PB107134-35

PB107135-35
automatic control systems: ventilation,
heating, animation, roller blind servo
controls, escalators, pumps, lighting,
signalling, monitoring, etc.

Time delay relays

iRTA iRTB iRTC


b Delays energizing of a b Applies a time delay to b Delays de-energizing of a
load energizing of a load upon load upon closing of an
closing of an auxiliary auxiliary contact (push
contact (push button) button)

Time delay
iRBN and iRTBT relays can interface
automatic control system inputs/
PB107144-35

PB107164-35
outputs with low-voltage devices.

Interface relays

iRBN iRTBT
Low level relay Extra low voltage relay
b Actuation of low-amperage electronic b Actuation of LV circuits
circuits upon receiving an LV electrical based on an extra low voltage
order order

Control
Control relays monitor electrical
parameters and indicate when they
PB107124-35

PB107125-35

are exceeded

Control relays

iRCP iRCI
Phase control Current control
b Monitors the order and asymmetry of b Monitors the current flowing in a
phases and the presence of voltage on circuit and indicates any crossing of
the 3 phases of a three-phase circuit the set threshold
(power supply of a motor, etc.)

Monitoring
I-42 Acti 9 | Catalogue 2014
Monitoring Relays (cont.)
Control
Remote control
PB107136-35

PB107137-35

PB107138-35
iRTH iRTL iRTMF
b Applies a time delay to b Applies a time delay to energizing b Allows one of the four types
energizing of a load and de-energizing of a load during of time delay to be selected:
different times, repeatedly (flasher) A, B, C or H

iRLI and iERL relays are used to relay


ON or OFF information to the auxiliary
PB107108-35

PB107109-35
circuits and actuate low-power loads

Changeover relays

iRLI iERL extension


Changeover
b Relays ON or OFF information to the auxiliary circuits
b Actuates low-power loads

Relaying and control


PB107126-35

PB107127-35

iRCU iRCC
Voltage control Compressor control
b Monitors the potential difference b Monitors the compressor power supply and
of a circuit and indicates any prevents its immediate restarting upon detection
crossing of the set threshold of a power cut or voltage dip

Acti 9 | Catalogue 2014 I-43


Monitoring Time delay relays
Control
Remote control iRTA, iRTB, iRTC, iRTH, iRTL
and iRTMF
Time delay relays
iRTA iRTB iRTC
Type

PB107133-35

PB107134-35

PB107135-35
Function
b Delays energizing of a load b Applies a time delay to energizing of b Delays de-energizing of a load upon
a load upon closing of an auxiliary closing of an auxiliary contact (push
contact (push button) button)
Wiring diagrams
DB123675

DB123676

DB123677
N N N
L L L

A1 15 A1 15 Y1 A1 15 Y1

18 16 A2 18 16 A2 18 16 A2

Use
DB123681

DB123682

DB123683

b The single time delay cycle starts at b The single time delay cycle starts at b The single time delay cycle starts
switching on of the iRTA relay power closing of an auxiliary contact (push only upon release of an auxiliary
supply button) contact (push button)
b The load is energized at the end of b The load is de-energized at the end b The load is de-energized at the end
time delay T of time delay T of time delay T
Catalogue numbers A9E16065 A9E16066 A9E16067

Technical specifications
Control and power supply V AC 24…240, ±10 % 24…240, ±10 % 24…240, ±10 %
voltage (Uc) V DC 24, ±10 % 24, ±10 % 24, ±10 %
Operating frequency Hz 50/60 50/60 50/60
Time delay range 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h
Precision ±10 % of full scale ±10 % of full scale ±10 % of full scale
Minimum duration of control impulse 100 ms 100 ms 100 ms
Insensitive to brownouts y 20 ms y 20 ms y 20 ms
Max. resetting time per voltage interruption 100 ms 100 ms 100 ms
Accuracy of repetition ±0.5 % at constant parameters ±0.5 % at constant parameters ±0.5 % at constant parameters
Changeover contact Mini Rating 10 mA/5 V DC Rating 10 mA/5 V DC Rating 10 mA/5 V DC
(cadmium free) Maxi Rating 8 A/250 V AC/DC Rating 8 A/250 V AC/DC Rating 8 A/250 V AC/DC
Endurance Mechanical > 5 x 106 switching operations > 5 x 106 switching operations > 5 x 106 switching operations
Electrical > 105 switching operations > 105 switching operations > 105 switching operations
(utilization category AC1) (utilization category AC1) (utilization category AC1)
Display of contact status by green indicator Flashing during time delay Flashing during time delay Flashing during time delay
lamp
Degree of protection Device only IP20 IP20 IP20
Connection by tunnel terminals Without 2 x 2.5 mm2 single-strand 2 x 2.5 mm2 single-strand 2 x 2.5 mm2 single-strand
ferrule
With ferrule 2 x 1.5 mm2 multi-strand 2 x 1.5 mm2 multi-strand 2 x 1.5 mm2 multi-strand
Width in 9-mm modules 2 2 2
Operating temperature °C -5 … +55 -5 … +55 -5 … +55
Storage temperature °C -40 … +70 -40 … +70 -40 … +70

I-44 Acti 9 | Catalogue 2014


Monitoring Time delay relays
Control
Remote control iRTA, iRTB, iRTC, iRTH, iRTL
and iRTMF (cont.)

iRTH iRTL iRTMF


PB107136-35

PB107137-35

PB107138-35
b Applies a time delay to energizing of a load b Applies a time delay to energizing and de- b Allows one of the four types of time delay to be
energizing of a load during different times, repeatedly selected: A, B, C or H
(flasher)

N N N N
DB123678

DB123679

DB123680
L L L L

A1 15 A1 15 A1 15 A1 15 Y1

18 16 A2 18 16 A2 18 16 A2 18 16 A2
DB123684

DB123685

b The single time delay cycle starts at switching on b The time delay cycle starts at energizing b Depending on the choice, the iRTMF generates
of the iRTH relay power supply b The load is energized during an adjustable time T1 time delay cycles for the iRTA, iRTB, iRTC or iRTH
b The load is de-energized at the end of time delay T and then de-energized during an adjustable time T2. relays
This cycle is reproduced until de-energizing of the
iRTL relay power supply
A9E16068 A9E16069 A9E16070

24…240, ±10 % 24…240, ±10 % 12…240, ±10 %


24, ±10 % 24, ±10 % 12…240, ±10 %
50/60 50/60 50/60
0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h
±10 % of full scale ±10 % of full scale ±10 % of full scale
100 ms 100 ms 100 ms
y 20 ms y 20 ms y 20 ms

I
100 ms 100 ms 100 ms
±0.5 % at constant parameters ±0.5 % at constant parameters ±0.5 % at constant parameters
Rating 10 mA/5 V DC Rating 10 mA/5 V DC Rating 10 mA/5 V DC
Rating 8 A/250 V AC/DC Rating 8 A/250 V AC/DC Rating 8 A/250 V AC/DC
> 5 x 106 switching operations > 5 x 106 switching operations > 5 x 106 switching operations
> 105 switching operations > 105 switching operations > 105 switching operations
(utilization category AC1) (utilization category AC1) (utilization category AC1)
Flashing during time delay Flashing during time delay Flashing during time delay

IP20 IP20 IP20


2 x 2.5 mm2 single-strand 2 x 2.5 mm2 single-strand 2 x 2.5 mm2 single-strand

2 x 1.5 mm2 multi-strand 2 x 1.5 mm2 multi-strand 2 x 1.5 mm2 multi-strand


2 2 2
-5 … +55 -5 … +55 -5 … +55
-40 … +70 -40 … +70 -40 … +70

Acti 9 | Catalogue 2014 I-45


Monitoring Interface relays iRBN, iRTBT
Control
Remote control

Interface relays
iRBN iRTBT
Type Low level Extra low voltage

PB107144-35

PB107164-35
Standard IEC 255 100 and IEC 529 IEC 255 100 and IEC 529
Function
b Actuation of low-amperage electronic circuits upon b Actuation of LV circuits based on an extra low voltage
receiving an LV electrical order order
Wiring diagrams
A1 11 A1 11
DB123686

DB123686

A2 12 14 A2 12 14

Use
b Inputs of programmable logic controllers, of measuring b ELV orders can be issued by a programmable logic
or supervision circuits, etc. controller (24 V DC static outputs), a central fire detection
unit, a regulation system, etc.
Catalogue numbers A9A15393 A9A15416

Technical specifications
Input control voltage (Uc) V AC 230, ±10 % 12...24, -15 to +10 %
V DC - 12...24, ±20 %
Output contact rating Mini 5 mA/5 V DC (DC12) 10 mA/10 V DC (DC12)
5 mA/5 V AC 10 mA/10 V AC
Maxi 1 A/24 V DC (DC12) 1 A/24 V DC (DC12)
5 A/250 V AC 5 A/250 V AC
Operating frequency Hz 50/60 0…60
Strengthened insulation between ELV/LV 4 kV 4 kV
circuits
Consumption At inrush 5 VA 0.22 W
At holding 2.5 VA 0.11 W
Endurance Electrical 100,000 switching operations 100,000 switching operations
Display of voltage presence on the control By green indicator lamp By green indicator lamp
circuit
Degree of protection Device only IP20 IP20
Connection by tunnel terminals 0.5 x 6 mm2 0.5 x 6 mm2
Width in 9-mm modules 2 2
Operating temperature °C -5 … +55 -5 … +55
Storage temperature °C -40 … +70 -40 … +70

I-46 Acti 9 | Catalogue 2014


Monitoring iRLI changeover and iERL
Control
Remote control extension relays

Changeover and extension relays


iRLI iERL
Type Changeover relay Extension for RLI

PB107108-35

PB107109-35
Standard IEC 255 and NF C 45-250 IEC 255 and NF C 45-250
Function
b Relaying of ON or OFF information to the auxiliary b Extension allowing additional contacts to be added to
circuits and actuation of low-power loads the iRLI changeover relays

Wiring diagrams
A1 1 5 1 5
DB123687

DB123688

A2 2 4 6 2 4 6

Use
b The iRLI relay contains 1 changeover contact (O-C) b The iERL extension (max. 3 iERLs for 1 iRLI) contains
and 1 normally open contact (N/O) 1 changeover contact (O-C) and 1 normally open contact
(N/O)
b Can be mounted without any tool and without
additional cabling using a yellow clip which performs
mechanical assembly and electrical connection between
the coils
Catalogue numbers A9E15535 A9E15536 A9E15537 A9E15538 A9E15539 A9E15540 A9E15541 A9E15542

Technical specifications
Control voltage (Uc) V AC 230…240 48 24 12 230…240 48 24 12
Voltage rating (Ue) V AC 230 230
Insulation voltage (Ui) V AC 250 250
Rating (In) A 10, cos φ = 1 10, cos φ = 1
Operating frequency Hz 50/60 50/60
Inrush and holding power 4 VA iRLI + iERL : 8 VA
Endurance Electrical 100,000 cycles AC21 (cos φ = 1) 100,000 cycles AC21 (cos φ = 1)
Commande directe en face Power By push button By push button
avant Coil By selector switch (disconnection) By selector switch (disconnection)
Position indicator Mechanical indicator Mechanical indicator
Marking Clip-on markers on the front panel Clip-on markers on the front panel
Degree of protection Device only IP20 IP20
Connection by tunnel terminals 0.5 x 6 mm2 0.5 x 6 mm2
Width in 9-mm modules 2 2
Operating temperature
Storage temperature
°C
°C
-5 … +55
-40 … +70
-5 … +55
-40 … +70 I

Acti 9 | Catalogue 2014 I-47


Monitoring iRCP phase control, iRCI current
Control control, iRCU voltage control and
Remote control
iRCC compressor control relays

Control relays
iRCI iRCU
Type Current control Voltage control

PB107125-35

PB107126-35
Function
b Monitors the current (Ir) flowing in an AC or DC circuit b Monitors the voltage variation (Ur) of an AC or DC
and indicates any crossing of the set threshold circuit and indicates any crossing of the set threshold

Wiring diagrams
N N N N
DB405266

DB405266
L L L L
0.15 A y Ir y 1.5 A 1 A y Ir y 10 A 10 V y Ur y 100 V 50 V y Ur y 500 V
AC/DC AC/DC

1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7

2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8

Catalogue numbers A9E21181 A9E21182

Common technical specifications


Supply voltage (Uc) V AC 230, -15 % à +10 %
Frequency Hz 50/60
Parameter setting b On the front panel, by direct scale, using a screwdriver
Precision of display ±10 % of full scale
Output by changeover contact 8 A under 250 V AC (cos φ = 1)
Indications by LED Green Voltage presence
Red Fault
Consumption VA 3
Dissipated power W 2
Degree of protection Device only IP20
Connection by tunnel terminals Rigid 1.5 x 6 mm2
cable
Width in 9-mm modules 4
Operating temperature °C -5 … +55
Storage temperature °C -40 … +80
Particular technical specifications
Threshold adjustable from 10 % to 100 % of Ir Threshold adjustable from 10 % to 100 % of Ur
Hysteresis adjustable from 5 % to 50 % of Ir Hysteresis adjustable from 5 % to 50 % of Ur
Monitoring of overcurrent and undercurrent (selection by selector switch)

Fail-safe contact
De-energized
Energized with fault
2 4 6 8

Energized without fault

2 4 6 8

Time delay on crossing threshold: 0.1 s to 10 s


Possibility of memorizing fault with resetting
Compatible with current transformers (CTs) of ratio X/5 b Automatic recognition of AC voltage or DC voltage.
b Automatic recognition of alternating or direct current. b 2 measuring ranges selected by cabling:
b 2 measuring ranges selected by cabling: v 10 V to 50 V
v 0.15 A to 1.5 A v 50 V to 500 V
v 1 A to 10 A

I-48 Acti 9 | Catalogue 2014


Monitoring iRCP phase control, iRCI current
Control
Remote control
control, iRCU voltage control and
iRCC compressor control relays
(cont.)

iRCP iRCC
Phase control Compressor control
PB107124-35

PB107127-35
b Monitors phases and the presence of voltage on the b Monitors the compressor's power supply and prevents its immediate restarting
3 phases of a three-phase circuit (power supply of a motor, etc.). It indicates any upon detection of a power cut or voltage dip
phase loss or inversion

L1 L1 N N
DB405265

DB405267

L2 L2 L L
L3 L3 t = 6 min. t = 3 min.
50 Hz 60 Hz
1 3 5 7 1 3 5 7 1 3 5 7 1 3 5 7

2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8

A9E21180 A9E21183

400, ±15 % 230, -15 % à +10 %


50/60
b On the front panel, by direct scale, using a screwdriver
±10 % of full scale
8 A under 250 V AC (cos φ = 1)
Voltage presence
Fault
3
3 (total on the 3 phases) 2
IP20
1.5 x 6 mm2

4
-5 … +55
-40 … +80

Setting of phase asymmetry threshold: 5 % to 2 5% of 400 V Threshold setting: ±5 % to ±15 % of 230 V


Hysteresis: fixed, 5 % of asymmetry threshold
Monitoring of direction of phase rotation

I
Monitoring of presence of the 3 phases
Fail-safe contact Fail-safe contact
De-energized De-energized
Energized with fault Energized with fault
2 4 6 8 2 4 6 8

Energized without fault Energized without fault

2 4 6 8 2 4 6 8

Time delay on tripping: 0.3 s Time delay on overshoot: 3 or 6 minutes (selection by cabling)

Acti 9 | Catalogue 2014 I-49


Notes
Bigger energy savings start with
the best energy efficiency education
Become an Energy Champion with
FREE courses from Energy University
Businesses everywhere are dealing with rising energy costs as well as
growing sustainability and regulatory concerns. Fortunately, there are Earn continuing education
practical, inexpensive solutions you can implement today to reduce energy credits at your convenience
use and increase savings. Energy University™ by Schneider Electric™ can
help.
Complete courses and you can earn
A free, online educational resource, Energy University offers more than continuing education credits or receive
200 timely courses on energy efficiency and data centre topics to help recognition from leading industry
you identify, implement, and monitor efficiency improvements within your associations, such as:
organization. Courses are self-paced and available on demand, so you can
create a learning schedule that meets your specific needs. > USGBC
Help your company achieve real energy savings with an efficiency > IEEE
education from Energy University.
> BOMI
> And many more!

Begin your efficiency education!


Register for FREE courses today.
Visit www.MyEnergyUniversity.com
or call +971 4 7099333

© 2014 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
• www.schneider-electric.com/ae • 998-1183625_GMA-UAE
Become an energy champion today!
Because saving energy is everyone’s business
> Free Energy Efficiency courses for you and your staff
> On-demand training takes less than an hour
> More than 50,000 courses completed to date
> Courses now available in multiple languages: Arabic, English, Enroll TODAY!
Classes are FREE, for a limited time only!
Chinese, Spanish, Italian, Russian, Brazilian Portuguese, German,
Visit www.MyEnergyUniversity.com
Dutch, French, Japanese, Korean and Turkish. and enter the key code 32323P
> More than 30,000 registered users from 120 plus countries

Stay connected all the time. Join us!


SE
“Like” and “Follow” Schneider Electric on TV
or visit www.schneider-electric.com/ae

© 2014 Schneider Electric. All rights reserved.

Make the most of your energy SM

Schneider Electric FZE


Due to evolution of standards and equipment, the
E Wing, Level 4, Dubai Silicon Oasis Headquarters,
characteristics indicated in texts and images of this
P.O. Box 341057, Dubai, United Arab Emirates
document do not constitute a commitment on our part
Phone: + 971 (4) 709 91 00
without confirmation.
Fax: + 971 (4) 709 91 01
Designed by: Dax Gaudiel, Marketing Communications,
www.schneider-electric.com/ae
Schneider Electric Gulf

Gulf0138EN September 2014

You might also like