The subsea tree shall be able to transmit any torque required to operate downhole
equipment.
BOP safety valve:
Shall be installed in the test string such that BOP rams can be closed on a slick
joint above the valve.
The safety valve assembly shall be equipped with a shearable sub located across
the rig BOP shear-ram. Required force to shear shall be documented.
The valve shall be of a pump through type.
The valve shall be able to cut coiled tubing with internal monoconductor cable
and/or 7/16" logging cable.
The valve shall be equipped with a chemical injection system with a double non
return valve located in tool assembly. The injection line shall be an integral part of
the control hose bundle.
Lubricator valve:
The lubricator valve shall be designed to be hydraulically pumped open and
closed, without failing to any position in case of lost control pressure. It shall be
possible to pump through the valve and also to pressure test against the valve from
both below and above.
Pressure lock between multiple valves run in combination shall not be possible.
Retainer valve:
The valve shall retain landing string fluid under pressure following a disconnect.
The valve shall be multi-shot.
The valve shall when included on the string not impair disconnect time.
The subsea test tree and retainer valve operating mechanism shall be such that both
automatically go to a safe closed position if the shearable sub is severed.
The subsea test tree and retainer valve systems shall include a system to allow
pressure testing of the landing string following reconnection.