P-067 Fuses, Travel Switches, Universal Change-over Switches, Connection Terminals Travel Switch

2. Type designation

YB LX K 3/ /

Operation modes (see Table1)

Type of protective enclosure(K、S、H)


Type of protective enclosure:
K: no protective enclosure, open type;
S: Vertical protective enclosure
with a cable entry at the bottom;
H: Horizontal protective enclosure with
a cable entry on the bottom and each side

Design sequence No.

Fast

Travel switch

Improved code

Contact type

YBLX-K3 Travel Switch 4(NO) 3(NO)


4(NO) 3(NO)

1. General
(S) (H)
YBLX-K3 series of travel switch is applicable to electric
circuit with voltage not more than AC-15 Ue 380V,50Hz/
1(NC) 2(NC) 1(NC) 2(NC)
60Hz or DC-13 Ue 220V and current not more than AC-15
Ie 5A 0.8A or DC-13 Ie 0.15A for travel control, direction of
motion or speed change of movement mechanism,
automatic control of machine tool, action limit &
travel or procedure control of movement mechanism.
Standard: GB/T 14048.5, IEC60947-5-1,CCC China
Compulsory Product Certification.

Table 1

Symbol Operation modes

Z Plunger type

L Roller plunger type

B Roller jib type

T Adjustable roller jib type

D Flexible rocker type

J Adjustable metal rocker type

H1 “cross” type, two wheels are in the same direction (upper left, upper right)

H2 “cross” type, left wheel is the front and the right wheel is on the back (upper left, lower right)

H3 “cross” type, left wheel is the front and the right wheel is on the back (lower left, upper right)

W Universal type
Travel Switch Fuses, Travel Switches, Universal Change-over Switches, Connection Terminals P-068

3. Technical data
Table 2
Ingress protection IP52
Rated voltage AC-15 380V ; DC-13 220V
Rated control current AC-15 0.8A ; DC-13 0.15A
Operation frequency 20 t/min
Ambient temperature -5℃~+40℃
Relative humidity ≤90%
Altitude ≤2000m
Installation category Ⅱ
Pollution degree class3
Insulation voltage Ui 415V
Rated impulse withstand voltage Uimp 2.5KV
For operation, control, limit, signal and interlock in control circuit and auxiliary circuit.
Scope of application
Typical application: control AC, DC electromagnets

Standard GB/T 14048.5 IEC 60947-5-1

Table 3
S S
YBLX-K3/20 H /B YBLX-K3/20 H /H1
Type S
YBLX-K3/20 H /Z
S S S S
S
YBLX-K3/20 H /T YBLX-K3/20 /D YBLX-K3/20 H /H2 YBLX-K3/20 H /W
Operating H
YBLX-K3/20 H /L S S
characteristic YBLX-K3/20 H /J YBLX-K3/20 H /H3
Maximum operating force (max OF) 30N 20N 20N 30N 20N
Maximum operating range ( max PT) 7mm 45° 45° 80° 45°
Maximum operating force (max OF) 2.0mm 20° 20° -

4. Overall and mounting dimensions


YBLX-K3/20S/Z YBLX-K3/20S/B

70max
41.5

Φ18
2×5.5×7.5

32±0.5

54.5

2×Φ5.5
100max

150max
60±0.5

2×5.5×7.5
60±0.5

2×Φ5.5
30±0.5 M20×1.5 15.5
42max 42max
30±0.5 15.5 M20×1.5
42max
42max

K
P-069 Fuses, Travel Switches, Universal Change-over Switches, Connection Terminals Travel Switch

YBLX-K3/20H/D YBLX-K3/20S/T

40±0.5 60max 70max


50

Φ18
113
2×5.5×7.5

200max
190max

2×5.5×7.5

60±0.5
2×Φ5.5
30±0.5 15.5 M20×1.5
62max 15.5
M20X1.5 44max 42max
42max

YBLX-K3/20S/W YBLX-K3/20S/H1, H2, H3

70max

Φ18
54.5
138max
2XΦ5.5
250max

2×5.5×7.5

60±0.5
60±0.5

2×Φ5.5

30±0.5 15.5 M20×1.5


15.5 30±0.5 42max
42max 42max
42max

5. Ordering information
When ordering, the user shall specify the product name, type and quantity.
For example: YBLX-K3/20S/T Travel switch 100 pieces
User note:
YBLX-K3/20S/B, YBLX-K3/20H/B, YBLX-K3/20S/T. YBLX-L3/20H/T restricted by operating mechanism.
It can not apply to the arm action is greater than 90 degree condition.
Beware of the action angle is too large lead to turn arm rotation and other undesirable phenomena.