Certificate N°: 2310300554

Page N°: 1/ 3

INSPECTION REPORT
In pursuance to an order for inspection given to us by our:
PRINCIPAL : BITUMEN HORMOZ PARS
GOOD DESCRIPTION : BITUMEN GRADE PG 70-10
(AS PROVIDED BY PRINCIPAL)
AT : ARYA SALAR WAREHOUSE -SHAHID RAJAEE PORT
ON : COMPLEX- BANDAR ABBAS- IRAN
OCTOBER 12TH 2023 TILL OCTOBER 12TH 2023
REQUIRED INSPECTION : TO REPORT PACKING & MARKING, RANDOM SAMPLING OF
THE CARGO, SENDING SAMPLE TO NON SGS LAB, STUFFING
SUPERVISION
We hereby report the followings:

Marking:
Following markings were observed on the body&/or top of drums, randomly inspected:

Type 1) Painted marking:

ALS
Premium Bitumen
Grade PG 70-10

Type 2) Engraved marking on top of drums:

ASIA

Packing:
The commodity was poured in the black appearance steel drums. Each drum has a lid on the top side.
Amongst the dimension checking of drums following figures were obtained:

Height of drums : 98.0 ± 0.5 Cm


Dia. of drums : 50.0 ± 0.5 Cm
Dia. of cap lid : 15.5 ± 0.5 Cm

This document is issued by the Company subject to its General Conditions of Service

SGS Iran Limited (www.sgs.com/en/Terms-and-Conditions.aspx). Attention is drawn to the limitations of liability,


indemnification and jurisdictional issues established therein.
No.73, Ahmad Ghasir St. This document is to be treated as an original within the meaning of UCP 600. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the
Arjantine Square time of its intervention only and within the limits of client’s instructions, if any. The Company’s
Tehran, Iran sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. Any
t: +98 21 887 36554 unauthorized alteration, forgery or falsification of the content or appearance of this document is
f: +98 21 887 31808 unlawful and offenders may be prosecuted to the fullest extent of the law.
The authenticity of this document may be verified at
https://sgsonsite.sgs.com/en/v2/common/ecertificate/authenticateeCertificate.jsp.
Certificate N°: 2310300554
Page N°: 2/ 3

Sampling:
Sampling was performed during stuffing the cargo into containers at warehouse, (The number of selected
drums:7 according to ASTM D140M–09, Standard Practice for Sampling Bituminous Materials).
Due to presenting cargo already packed in drums at the time of inspection, we’ve been restricted to take
the increments from top level of drums only.

All drawn samples were mixed well, and 4x1 L. Composite samples were prepared; distributed as follows:
-1x1 L. composite sample was dispatched to non SGS lab seal No.834813
-3x1 L. composite samples were retained by SGS for 90 days with SGS seal Nos.834814, 834815, 834816
& 834817

Analysis:
One composite sample was sent to non-SGS laboratory for the following items to be tested. The following
specification and test method were reported by the lab:

REQUIRED RANGE
DECLARED BY
SPECIFICATION TEST METHOD RESULT PRINCIPAL
MIN. MAX.
FLASH POINT, °C ASTMD92 292 230 --
VISCOSITY @135°C .PA.S ASTMD4402 0.54 -- 3
G*/SIN σ (ORGINAL BINDER) @70°C,KPA ASTMD7175 1.13 1 --
G*/SIN σ (RTFOT) @70°C,KPA ASTMD7175 2.86 2.20 --
ROLLING THIN FILM OVEN TEST, % ASTMD2872 <1 -- ±1
DSR (PAV) @28°C, KPA ASTMD7175 4228 -- 5000
M.VALUE @0°C, (BBR) ASTMD6648 0.31 0.300 --
GREEP STIFFNESS, S, 0°C MPA,(BBR) ASTMD6648 100.2 -- 300
These findings are reported herein for convenience only and SGS has no liability for the subcontracted
results which remain with the lab.

Stuffing drums into containers:


-Each take of forklift discharged 8~12 drums which were directly stuffed into nominated containers. In each
container two tiers of drums were stuffed, in first tier 55 and second tier 55 drums were stuffed (Totally 110
drums in each container).

Stuffed containers:
The commodity was stuffed into 2 x 20 Ft. containers under our supervision as following:
No. Container No. QTY. of drums SGS seal Stuffing date
1 FSCU 323297-1 110 Drums C891919 12.10.2023
2 BSIU 329227-0 110 Drums C891920 12.10.2023
The sole function of any seals applied by SGS is to indicate that the material bearing such seals has been
inspected by SGS.
Seals applied by SGS are not intended to secure material, lock the container of such material, or otherwise
provide any security function. SGS does not provide security services and disclaims any liability in this
respect.

This document is issued by the Company subject to its General Conditions of Service

SGS Iran Limited (www.sgs.com/en/Terms-and-Conditions.aspx). Attention is drawn to the limitations of liability,


indemnification and jurisdictional issues established therein.
No.73, Ahmad Ghasir St. This document is to be treated as an original within the meaning of UCP 600. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the
Arjantine Square time of its intervention only and within the limits of client’s instructions, if any. The Company’s
Tehran, Iran sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. Any
t: +98 21 887 36554 unauthorized alteration, forgery or falsification of the content or appearance of this document is
f: +98 21 887 31808 unlawful and offenders may be prosecuted to the fullest extent of the law.
The authenticity of this document may be verified at
https://sgsonsite.sgs.com/en/v2/common/ecertificate/authenticateeCertificate.jsp.
Certificate N°: 2310300554
Page N°: 3/ 3

Quantity:
Total stuffed containers : 2 Containers
Total Number of drums : 220 Drums

Note:
-The floor of nominated empty containers was covered by a layer of P-E sheet.
-About 5 ~ 10 % of drums suffered from slight dents on bodies during stuffing operation. (This due to the
loading method performed by the manpower and machine/forklift, which the drums were in the sound
condition in an appearance before stuffing into containers).
SGS Tehran, October 23RD., 2023
23-08340L02,
(MT)

This document is issued by the Company subject to its General Conditions of Service

SGS Iran Limited (www.sgs.com/en/Terms-and-Conditions.aspx). Attention is drawn to the limitations of liability,


indemnification and jurisdictional issues established therein.
No.73, Ahmad Ghasir St. This document is to be treated as an original within the meaning of UCP 600. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the
Arjantine Square time of its intervention only and within the limits of client’s instructions, if any. The Company’s
Tehran, Iran sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. Any
t: +98 21 887 36554 unauthorized alteration, forgery or falsification of the content or appearance of this document is
f: +98 21 887 31808 unlawful and offenders may be prosecuted to the fullest extent of the law.
The authenticity of this document may be verified at
https://sgsonsite.sgs.com/en/v2/common/ecertificate/authenticateeCertificate.jsp.

You might also like