JPEP-0-1360-F-1151 Rev.0
This Document is of a confidential nature and is the property of JGC CORPORATION, PIPING
ENGINEERING DEPARTMENT and shall not be traced, photographed, photostated or reproduced in any
manner, nor used for any purpose whatsoever except by written permission of PIPING ENGINEERING
DEPARTMENT of JGC CORPORATION.
FILING CODE
DATE - -
JOB CODE - - - -
CLIENT
PROJECT
LOCATION
DIST'N DIV.
CLIENT
DEPT.
H.OFFIC
E PREP'D
FIELD
JGC CHK'D
APP'D
FIELD
JPEP-0-1360-F-1151 Rev.0
Page 2 of 9
PRACTICE
Plan for Practical Use of JPEP JPEP-0-1360-F-1151 Rev.0
1. SCOPE
This plan is the instruction for practical use of JPEP for the job execution in LCE.
1360 1110 Scope JPEP-0-1360-B-1111 0 Split of Work with Other Engineering Departments
1360 1150 Execution & Tool JPEP-0-1360-G-1151 0 Job Execution Flow of Piping Engineering
1360 2100 Design Basis & Procedure JPEP-0-1360-G-2101 0 Work Package of Piping Design Engineering
1360 2110 Prep. of Piping General Spec. JPEP-0-1360-S-2111 0 Piping Design (General)
Prep. of Eng'g Exec.
1360 2120 Procedure
1360 2200 Line Index JPEP-0-1360-G-2201 1 Preparation Procedure for Line Index
1360 4250 Piping Layout(Hose Station) JPEP-0-1360-G-4251 1 Design Guide for Hose Station Piping
Piping Layout around Static
1360 4300
Equipment
1360 4310 Tower Piping JPEP-0-1360-S-4311 0 Design Criteria for Piping Arrangement (Around Column)
1360 4320 Drum Piping JPEP-0-1360-S-4321 0 Design Criteria for Piping Arrangement (Around Vessel)
Heat Exchanger Piping(S&T) Design Criteria for Piping Arrangement (Around Heat
1360 4330 JPEP-0-1360-S-4331 0
Exchanger)
Design Guide for Piping Arrangement Around Heat
JPEP-0-1360-G-4331 0
Exchanger
Design Work Flow for Piping Arrangement Around Heat
JPEP-0-1360-G-4332 0
Exchanger
Air Fin Cooler Piping Design Guide for Piping Arrangement Around Air Cooled
1360 4340 JPEP-0-1360-G-4341 0
Heat Exchanger
Design Work Flow for Piping Arrangement Around Air
JPEP-0-1360-G-4342 0
Cooled Heat Exchanger
1360 4350 Furnace Piping JPEP-0-1360-G-4351 1 Design Guide for Piping Arrangement Around Heater
Inf. for Structure Design Calculation Procedure for Reaction Force and Stress of
1360 4710 JPEP-0-1360-G-4711 0
Pipe Rack/Sleeper Piping
1360 4720 Inf. for Civil Design
Inf. for Equipment Design Procedure for Preparing Information for "Forces and
1360 4730 JPEP-0-1360-G-4731 0
Moments Acting on Equipment Nozzles"
Information for Forces and Moments acting on Vessel
JPEP-0-1360-F-4731 0
Nozzles
1360 4800 Piping Drawing JPEP-0-1360-G-4801 0 Verification Procedure for Piping Drawing
JPEP-0-1360-D-5139 0 Standard Pipe Support (Slide Shoe and Slide Guide P25)
Standard Pipe Support (Heat Insulation Block for Cold
JPEP-0-1360-D-5140 0
Insulation Piping P91)
Prep. of Exec. Procedure for
1360 5170
Piping Mechanical Analysis
JPEP-0-1360-G-5171 0 Execution Procedure for Piping Strength Analysis
1360 7300 Preparation of BM/BQ Job Dat JPEP-0-1360-F-7301 0 Job Data Report (PIPING)
Page 8 of 9
PRACTICE
JPEP-0-1360-F-1151
Plan for Practical Use of JPEP
No.
Information of JPEP Modification Items
Sheet No. of
JPEP No. Rev. Title
Item modified
(No./ Title) Content of modification Reason of modifications
JPEP-0-1360-F-1151 Rev.0