NOTES:-

1. DIMENSIONS ARE IN mm AND LEVEL IN METRE.


3'-0" 2. FIGURED DIMENSIONS SHALL BE FOLLOWED. DO NOT
T SCALE THE DRAWING.
3. STRUCTURAL DRAWINGS SHALL BE READ IN
CONJUNCTION WITH ARCHITECTRUAL DRAWINGS.

5'-0"
X X 4. ANY DISCREPANCY IN DRAWINS SHALL BE BROUGHT
IN TO THE NOTICE OF CONSULTANTBEFORE EXIECUTION.
5. IN CASE OF DOUBT ASK CONSULTANT BEFORE EXECUTION.
6. COLUMN FOOTINGS ARE CONCENTRIC WITH COLUMN
Y Y UNLESS OTHERWISE INDICATED IN DRAWINGS.
7. COLUMN BARS SHOULD BE STAGGERED.
8. LAP LENGTH AS PER SPECIFICATION.
9. CONCRETE GRADE SHALL BE:
a) FOR O/H & U/G WATER TANKS......................M 25
c) FOR FOOTINGS ............................................. M 25
PLAN b)FOR COLUMNS, BEAMS AND SLABS .............. M 25
10. CLEAR COVER TO MAIN REINFORCEMENT SHALL BE-

16"
SHOE FOOTING BEAMS: 30MM, SLABS: 20MM, COLUMN:40MM , FOOTING: 50MM
'-0" 11. FOR CANTILEVER BEAMS TOP REINFORCEMENT TO BE
5
ANCHORED BEHIND FOR DEVELOPMENT LENGTH
EQUAL TO (75XD) OR SPAN OF CANTILEVER WHICHEVER
IS GREATER.
3'-0"
12. DESHUTTERING PERIOD SHALL NOT BE LESS THAN
SPECIFIED BELOW
ISOMETRIC VIEW A)a)SLABS UP TO 3.5M SPAN = 7DAYS
b)SLABS WITH SPAN BETWEEN 3.5M TO 6.0M = 14DAYS.
c)SLABS WITH SPAN MORE THAN 6M = 21DAYS.
B)a)BEAMS UP TO 3.0M SPAN = 14DAYS.
b)BEAMS WITH SPAN MORE THAN 3.0M = 21DAYS.
C) VERTICAL FACES OF COLUMNS, BEAMS & R.C.C.WALLS =24 HR.
R.C. COLUMN 13. SUBSTRATUM SHOULD BE APPROVED FROM OUR
OFFICE BEFORE LAYING P.C.C.
GL 14. CENTERING & SHUTTERING SHALL BE CONTRACTORS
RESPONSIBILITY.
COLUMN STEEL 15. ALTERNATE BENT UP MUST BE PROVIDED FOR SLAB
BARS HAVING SPAN MORE THAN 5'.
TOP & BOTTOM JALI COLUMN LINKS 16. PROVIDE 2 - 10 TOR mm SIDE FACE REINFORCEMENT
10TOR @ 6" C/C ON FACE FOR BEAM HAVING DEPTH 750mm OR MORE.
@8TOR @6" C/C
REVISED
REV. DATE DESCRIPTION BY
COLUMN STEEL
(STRAIGHT) R0 21-03-2024 ---- VM
16"

GRADE OF CONCRETE - M25 DESIGN FOR G+1

GRADE OF STEEL - FE500 SBC - 350 KN/SQM

16"
TOP & BOTTOM JALI CLIENT - -----------
10TOR @ 6" C/C 3'-0"
3'-4" P.C.C. STRUCTURAL DESIGNER -
P.C.C. 6" THK. [150 THK.]
SECTION Y-Y ARCHITECT - ---------
3'-0"
PROJECT - RESIDENTIAL BUILDING
SECTION X-X
DRAWING TITLE - RCC DETAIL OF COLUMN AND FOOTING
ECCENTRIC DETAILS OF C1 & C3 CHECKED BY DEALT BY DRAWN BY
VM AS AS
DWG. NO. - 02/2024/------ - - R0

A3