RIVER HOOGHLY

GENERAL NOTES:
1) Drawings shall be read in conjunction with architectural dwgs.
RIVER HOOGHLY 2) All dimensi0ns are in mm unless specified Otherwise.
3)Dimensions 0f the drawings shall not Le scaled.
4) Written dimensions should be followed. In case 0f ant discrepancy the
same shall be referred to the architect.
5) Steel grade is Fe 415 D for all bars except 6mm bars, which shall be of mild steel.
ROAD 3.35 M WIDE 6) Reinforcement Concrete shall be M25 f0r all R.C.C items.
7) N0rmal cover t0 all reinforcement shall be
LVL -250
(a) F0undation--60 mm (b) Column--40 mm (C) Beam--25mm (d) Slab--15 mm
RESIDENTIAL AREA 8) Lap length requirement are as f0II0WS
(a) N0t more than 50% bars shall be lapped at a section(U.N.0)
(b) Laps are 48 times dia 0f bar
N0 lapping shall be done for cantilever beam.
(c) When bars of 2 different diameters are to be lapped, lap length shall be based 0n
250 THK WALL diameter of smaller bar.
RESIDENTIAL AREA 9) Spacer bars of 25mm dia or maximum dia of Longitudinal bar, whichever is higher shall be
GATE provided between 2 layers of Longitudinal reinforcement in beam.
10) The concrete is assumed to be machine mixed.
11)All covers shall Le ensured by precast cover blocks make of C:M 1:3 and dip cured
LVL +0 for 7 days with embedded binding wires for trying them.
12)All top bars of slab shall be supported with Chairs 0f appropriate dia at 1000 mm c/c.
13)Isolated footing is adopted,SBC: 200kN/m2
14)Foundation is designed for G+2
WAY TO GHAT
EXISTING STRUCTURE

7900
RESIDENTIAL AREA
CLUB

5906
MANDIR
4400

SIGNATURE OF ENGINEER
1350
2100

GATE
1251

ROAD 9.3 M WIDE 1842

SIGNATURE OF CHAIRMAN
RESIDENTIAL AREA
TITLE:

SHEET SIZE -A3 DRAWING NO: CONS/KCD-04 SCALE: 1 : 100


N
DRAWN BY: M.S.G. DATE: 10-06-2023 REVISION: 0