WATER
TANK
SLURRY WATER TANK
SCALE - 1:50
1500X1000
MIST ELIMINATOR
1000X1000
BLOWER
500Ø
1550X1550
SCRUBBER
NEW CHIMNEY
700Ø
VENTURY
GENERAL NOTES:
POLLUTION CONTROL UNIT 1)Drawings shall be read in conjunction with architectural dwgs.
2) All dimensi0ns are in mm unless specified Otherwise.
FOR NEW CREMATORIUM 3) Dimensions 0f the drawings shall not Le scaled.
SCALE:-1:100 4) Written dimensions should be followed. In case 0f ant discrepancy the
FRONT ELEVATION same shall be referred to the architect.
5) Steel grade is Fe 415 D for all bars except 6mm bars, which shall be
SCALE 1:100
of mild steel.
6) Reinforcement Concrete shall be M25 f0r all R.C.C items.
7)N0rmal cover t0 all reinforcement shall be
(a) F0undation--60 mm (b) Column--40 mm (C) Beam--25mm (d) Slab--15
SCRUBBER
SCRUBBER
1550X1550
1550X1550
VENTURY
VENTURY
mm
500Ø
500Ø
SLURRY
SLURRY
WATER
WATER
TANK
TANK
1000X1000
1000X1000
BLOWER
BLOWER
8)Lap length requirement are as f0II0WS
700Ø
700Ø
(a) N0t more than 50% bars shall be lapped at a section(U.N.0)
MIST ELIMINATOR
MIST ELIMINATOR
NEW CHIMNEY
NEW CHIMNEY
(b) Laps are 48 times dia 0f bar
N0 lapping shall be done for cantilever beam.
1500X1000
1500X1000
(c) When bars of 2 different diameters are to be lapped, lap length shall
be based 0n diameter of smaller bar.
9)Spacer bars of 25mm dia or maximum dia of Longitudinal bar, whichever
is higher shall be provided between 2 layers of Longitudinal reinforcement in
beam.
OPERATOR 10) The concrete is assumed to be machine mixed.
2500 X 2000
ASH COLLECTION
ASH COLLECTION
11)All covers shall Le ensured by precast cover blocks make of C:M 1:3
STOOL
FURNACE ABOVE
STOOL LVL +2350 LVL +3600 LVL +3900 and dip cured
LVL +900 WAITING AREA
4350 X 2190
for 7 days with embedded binding wires for trying them.
OFFICE
UP 1725 X 2000 12)All top bars of slab shall be supported with Chairs 0f appropriate dia at 1000
mm c/c.
13)Isolated footing is adopted,SBC: 200kN/m2
CONTROL
14)Foundation is designed for G+2
PANEL LVL +3900
UP
2000
DN
SIGNATURE OF ENGINEER SIGNATURE OF CHAIRMAN
UP