Design Of Isolated Footing 1 of 3

1 Footing Size Design

Load Pu 100 KN
Design Load P 73 KN

Moment in x dir Mux 50 KN-m


Moment in y dir Muy 50 KN-m

Column size cx 600 mm


cy 250 mm

SBC q 150 KN/sqm

Footing Size required A req 0.49 sqmm

L 2.00 meters
Footing Size Provided
B 2.00 meters
Area Provided A prvd 4.00 meters

Zx 1.33
Zx 1.33

Net upward pressure Nup 68 KNm2

Footing Size OK

2 Slab Design
lx 0.700
ly 0.875

Bending Moment in x dir Mx 25 KN-m


Bending Moment in y dir My 39 KN-m

Concrete fck 20 MPa


Steel fy 415 MPa

Minimum Depth Required dmin 119

Depth Provided D 500 mm


Clear Cover c 50 mm
Effective Cover d' 60 mm
Effective Depth d' 440 mm

Spacing c/c in mm
Area of Steel
12# 16# 20#
1320 sqmm 86 c/c 152 c/c 238 c/c
1320 sqmm 86 c/c 152 c/c 238 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion

Ast across x direction 20 mm dia @ 230 mm c/c 1366 sqmm


Ast across y direction 20 mm dia @ 230 mm c/c 1366 sqmm

1
Design Of Isolated Footing 2 of 3
3 One Way Shear along x direction

Vu1 53 KN
ζv 0.061 MPa

ζc 0.388 MPa
Vc1 342 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 89 KN
ζv 0.101 MPa

ζc 0.388 MPa
Vc1 342 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 336 KN
ζv 0.221 MPa

ks*ζc 1.025 MPa


Vc1 1560 KN

Two Way Shear Check OK

2
Design Of Isolated Footing 3 of 3
L= 2.00 meters

250

600
B= 2.00 meters

200 mm 500 mm

20 mm dia @ 230 mm c/c 20 mm dia @ 230 mm c/c