Che541 Design of grit chamber ,Trickling Filter and oxidation pond
1) Design a grit chamber of rectangular cross-section. Following information
is provided: Design Flow (Q): 50 MLD; Settling velocity of the smallest particle to be removed completely is 0.0236 m/s; Specific Gravity of particles (Ss): 2.65; Horizontal mean flow velocity (V): 0.30 m/s; Theoretical depth (D): 1.4 m; Calculate the dimensions and slope (mm/m) of the grit chamber. While designing the actual grit chamber, add 25 percent to the depth for grit collection, and 0.25m freeboard. Also add 50 percent to the theoretically calculated length. Value of Manning’s ‘n’ is 0.020. Assuming that the volume of grit in the wastewater is 0.15 m3/ML, and 100 percent grit removal in the grit chamber, calculate the total mass and mass of dry grit produced per day. The collected grit has a porosity of 0.5.
2) A tricking filter with the following dimensions is available. Depth: 2 m,
Surface area: 150 m2. The media consists of stones of 7-10 cm diameter. This filter will be used to treat 0.6 MLD wastewater with BOD 5 = 300 mg/L. The trickling filter will be operated in the high-rate mode, i.e., OLR: 0.48 – 0.96 Kg/m3/d, HLR: 10 – 40 m3/m2/d, re-circulation ratio: 1-2. Based on this information, calculate the expected BOD5 removal efficiency.
3) Determine bulk volume of filter medium for treating 2mld of wastewater
flow with following data Inlet BOD5 =300 mg/l, Effluent BOD5 =30 mg/l, BOD removal efficiency = 75%, K=0.068 m/d, Sp. Surface area = 80 m 2/m3.
4) 1 MLD of wastewater with influent soluble BOD5 (S o) = 75 mg/L, TKN = 13
mg/L (as N) and 2 mg/L phosphorus (as P) is to be treated in an oxidation pond such that effluent soluble BOD 5 (S) is 5 mg/L. Calculate the oxidation pond surface area, assuming the depth of the pond to be 0.5 m. Calculate oxygen requirement for microbial respiration and oxygen supplied by algal growth, and check adequacy of the design by assuming that 50 percent of the oxygen produced by algal growth is available for microbial respiration. Neglect oxygen input into the pond by mass transfer from atmosphere. Calculate the effluent algal, effluent nitrogen and phosphorus concentration from the pond, and also calculate the total effluent BODU from the pond.