Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

REPUBLIC OF THE PHILIPINES

DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS


REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN

C.Y. 2023 PROJECT


"AS-STAKED" PLAN FOR
Construction of Solar Water System, Brgy. Aranas, Balete, Aklan
BALETE, AKLAN
CONTRACT I.D.: 23GA0138

PREPARED: REVIEW AND SUBMITTED: RECOMMENDED: APPROVED:

PROJECT MANAGER JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
GREEN BUILDERS ENGINEER II CHIEF, PLANNING DESIGN AND SECTION OIC-ASSIST DISTRICT ENGINEER DISTRICT ENGINEER
OIC, CONSTRUCTION SECTION
DATE: DATE: DATE: DATE: DATE:
SUMMARY OF QUANTITIES

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan SUMMARY OF QUANTITIES REPUBLIC OF THE PHILIPINES JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS 1
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
GREEN BUILDERS PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
PROJECT ENGINEER ENGINEER II
OIC-CHIEF, CONSTRUCTION SECTION
CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
1 13
KALIBO, AKLAN TOTING REYES ST. KALIBO, AKLAN
DATE: DATE: DATE: DATE: DATE:
DATE: BALETE, AKLAN
GENERAL NOTES :
THIS STANDARD PLAN IS ONLY A GUIDE FOR RURAL
WATER SUPPLY FOR LEVEL II & III.

I. GENERAL 3. STRUCTURAL STEEL VI. SOLAR PANELS IX. ABBREVIATIONS


3.1. ALL STRUCTURAL MILL SECTIONS AND BUILT UP PLATE SECTIONS SHALL BE 1. BASIC WIND VELOCITY IN THE DESIGN, V = 250 kph
1. THESE NOTES SHALL APPLY UNLESS SPECIFICALLY OTHERWISE INDICATED IN BOTT. BOTTOM BARS
DESIGNED IN ACCORDANCE WITH AISC'S LATEST SPECIFICATION FOR THE
THE PLANS. IN CASE OF CONFLICT BETWEEN PLANS AND SPECIFICATION, 2. SOLAR PANEL ORIENTATION SHALL GENERALLY BE FACING TRUE SOUTH FOR C COLUMN
DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR
SPECIFICATION SHALL GOVERN. MAXIMUM OUTPUT OF POWER BUT OPTIMUM RADIATION EXPOSURE SHALL BE C.H.B. CONCRETE HOLLOW BLOCK
BUILDINGS.
2. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED IN THE CONSIDERED AT ALL TIMES BASED ON PROJECT LOCATION. CONC. CONCRETE
3.2. DESIGN LOADS SHALL MEET THE REQUIRED STRUCTURAL DESIGN
PLANS. 3. SOLAR PANEL MODULES SHALL BE OF MONO CRYSTALLINE OR cm CENTIMETER
CRITERIA.
3. ALL ELEVATION ARE IN METERS UNLESS OTHERWISE NOTED IN THE PLANS. POLY-CRYSTALLINE TYPE.
3.3. STEEL PLATES, SHAPES, BARS AND METAL FABRICATION: ASTM A-36. DWG DRAWING
4. ALL DIMENSIONS AND ELEVATION SHOWN IN THE PLANS SHALL BE VERIFIED 4. ALL ROOF PENETRATIONS SHALL BE SEALED WITH A HIGH PERFORMANCE ROOF
3.4. STRUCTURAL BOLTS AND NUTS: ASTM A-325, GALVANIZED. 7/8Ø AND BELOW. D DOOR
BEFORE COMMENCEMENT OF THE WORKS. SEALANT.
5. ALL DIMENSIONS, ELEVATIONS AND LOCATION OF OPENING RELATED TO THE 5. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY DS DOWNSPOUT
EQUIPMENT ARE TENTATIVE AND SUBJECT TO CHANGE AFTER THE EQUIPMENT PLUMBING, MECHANICAL, OR BUILDING ROOF VENTILATION. EA EACH
DIMENSIONS HAVE BEEN ESTABLISHED. 6. APPROPRIATE CAUTION AND WARNING ELECTRICAL SIGNS AND SIGNAGES E.F EACH FACE
IV. MECHANICAL NOTES SHALL BE POSTED AT CONSPICUOUS LOCATION AT THE SITE.
E.W EACH WAY
II. DESIGN CRITERIA AND SPECIFICATIONS EL, ELEV ELEVATION
1. ALL MECHANICAL WORKS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION
1. DPWH DESIGN GUIDELINES, CRITERIA, AND STANDARDS (DGCS) - VOLUME 3 2015 OF THE PHILIPPINE MECHANICAL ENGINEERING CODE.
VII. AQUIFER / PUMP WELL FLR FLOOR
F.T.G. FOOTING TIE BEAM
EDITION 2. THE TOTAL SCOPE OF WORKS SHALL INCLUDE ALL WORKS DESCRIBED IN PLANS
2. DPWH STANDARD SPECIFICATIONS FOR HIGHWAYS, BRIDGES, AND AIRPORTS - AND LISTED IN TECHNICAL SPECIFICATIONS FOR MECHANICAL WORKS. 1. WELL DRILLING WILL COMMENCE UPON SECURING OF DRILLING PERMIT FROM G.I. GALVANIZED IRON
VOLUME II, LATEST EDITION 3. THE WORK SHALL BE EXECUTED IN CLOSE COORDINATION WITH OTHER THE NWRB AND MUST BE CONTRACTED TO AN EXPERIENCED AND COMPETENT GRD, GRND GROUND
3. DPWH STANDARD SPECIFICATIONS FOR PUBLIC WORKS STRUCTURES TRADES. WELL DRILLING COMPANY DULY ACCREDITED BY THE NWRB. HOR. HORIZONTAL
(BUILDINGS, PORTS AND HARBORS, FLOOD CONTROL AND DRAINAGE 4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, TECHNICAL DATA / 2. THE CONDUCT OF GEO-RESISTIVITY TEST SHALL BE PERFORMED IN THE L LENGTH
STRUCTURES AND WATER SUPPLY SYSTEMS) - VOLUME III, 2019 EDITION SPECIFICATION (BROCHURES/CATALOGUE) SUBJECT FOR FURTHER TECHNICAL TARGET AREA TO IDENTIFY THE LOCATION AND DEPTH OF AQUIFER OF THE m METER
4. RURAL WATER SUPPLY VOLUME I DESIGN MANUAL. EVALUATION OF THE CONCERNED AUTHORITY PRIOR TO PROCUREMENT / PROPOSED WELL SITE.
mm MILLIMETER
5. PHILIPPINE SOCIETY OF MECHANICAL ENGINEERING CODE. INSTALLATION OF THE EQUIPMENT / UNIT. 3. THE DESIGNER SHALL CONDUCT A PUMPING ("SAFE YIELD") TEST AT LEAST
6. PHILIPPINE ELECTRICAL CODE. 5. PROVIDE SEISMIC RESTRAINTS FOR ALL RIGIDLY & RESILIENTLY SUPPORTED EQUAL TO THE SYSTEM PEAK DEMAND AND OPERATE IT FOR 24-48 HOURS. ND NOMINAL DIAMETER
7. NATIONAL STRUCTURAL CODE OF THE PHILIPPINES, VOLUME I (BUILDING, EQUIPMENT FOR APPLICABLE CODE & AS SPECIFIED DESIGN & PROVIDE 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR WELL HEAD PROTECTION TO N NORTH
TOWERS AND OTHER VERTICAL STRUCTURES) 7TH EDITION 2015, (NSCP). RESTRAINTS FOR PUMPS, FANS, TANKS, ALL PIPING WORKS, GENERATORS PROVIDE SEAL FROM LEAKAGE AND RUNOFF ENTERING THE WELL HEAD. NGL NATURAL GRADE LEVEL
ENGINE EXHAUST PIPES, ETC. RESTRAINTS SHALL BE DESIGNED TO PREVENT N.T.S. NOT TO SCALE
III. CIVIL AND STRUCTURAL DESIGN PERMANENT DISPLACEMENT IN ANY DIRECTION CAUSE BY LATERAL MOTION.
PV PHOTOVOLTAIC
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TESTING AND
COMMISSIONING OF ALL EQUIPMENT INSTALLED. R.C. REINFORCED CONCRETE
1. REINFORCED CONCRETE VIII.TRANSMISSION AND DISTRIBUTION SYSTEMS STD STANDARD
7. PROVIDE PIPE SLEEVES FOR ALL PIPING PASSING THROUGH BUILDING
SCHEDULE OF STRUCTURAL CONCRETE STRUCTURES. STL STEEL
8. PROVIDE GUIDES, HANGER AND SUPPLEMENTAL SUPPORT STEEL FOR ALL 1. TRANSMISSION AND DISTRIBUTION SYSTEMS VARY IN SIZE AND COMPLEXITY
t, THK THICKNESS
PIPING. BUT ALL HAVE THE SAME BASIC PURPOSE TO DELIVER WATER, HENCE, SOURCE
TO HOUSEHOLD DISTRIBUTION SHALL BE UNDERTAKEN BY THE IMPLEMENTING TDH TOTAL DYNAMIC HEAD
9. ALL STEEL PIPE SUPPORTS SHALL BE PHOSPHATED PRIOR TO APPLICATION OF
TWO COATS OF RED LEAD AND A COAT OF ENAMEL PAINT FOR FINISHING. OFFICE. TYP TYPICAL
10. THE QUANTITY OF EACH EQUIPMENT INDICATED IN THE SCHEDULE IS FOR 2. METHODS OF WATER TRANSMISSION AND DISTRIBUTION SHALL BE BASED ON T.B. TOP BAR
GUIDANCE ONLY. FOR QUANTITY TAKE OFF COUNT THE NUMBER OF UNITS IN THE GUIDELINES PROVIDED IN RURAL WATER SUPPLY, VOLUME I (DESIGN VERT VERTICAL
THE PLANS. MANUAL).
W/ WITH
11. ALL MECHANICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
W/O WITHOUT
SUPERVISION OF A DULY REGISTERED MECHANICAL ENGINEER.
W.P WATER PROOFING

1.1. LOCATION OF ALL CONSTRUCTION OR COLD JOINTS MUST BE APPROVED BY


V. ELECTRICAL NOTES
THE ENGINEER.
1.2. REINFORCING BARS, ANCHOR BOLTS, AND OTHER INSERTS SHALL BE 1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE AND IN STRICT
SECURED IN PLACE BEFORE POURING CONCRETE, BAR PLACEMENT AND COMPLIANCE WITH THE PROVISIONS OF THE LATEST EDITION OF THE
SUPPORTS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED ACI PHILIPPINE ELECTRICAL CODE (PEC) EXISTING APPLICABLE LAWS, ORDINANCES,
PRACTICE. REQUIREMENTS, RULES AND REGULATIONS OF THE LOCAL GOVERNMENT AND
LOCAL POWER COMPANY.
2. REINFORCING STEEL 2. WHEREVER REQUIRED AND NECESSARY, JUNCTION BOXES OR PULL BOXES
SHALL BE INSTALLED AT INCONSPICUOUS LOCATIONS ALTHOUGH SUCH BOXES
SCHEDULE OF REINFORCING BARS ARE NOT SHOWN ON THE PLANS NOR MENTIONED IN THE SPECIFICATIONS.
3. ALL NON-CURRENT CARRYING METAL PARTS/ ENCLOSURES OF ELECTRICAL
EQUIPMENT AND OVERCURRENT PROTECTIVE DEVICES SHALL BE PROPERLY
GROUNDED IN ACCORDANCE WITH ARTICLE 2.50 OF THE PHILIPPINE ELECTRICAL
CODE PART 1, 2000 EDITION
4. THE ELECTRICAL SYSTEM SHALL HAVE A GROUND RESISTANCE NOT
EXCEEDING 5 OHMS.
5. STANDARD TYPE OF ACCESSORIES, SPLICING DEVICES, TERMINATIONS AND
OTHER APPURTENANCES FOR THE ENTIRE ELECTRICAL INSTALLATION SHALL BE
USED.
6. ALL MATERIALS TO BE USED AND INSTALLED SHALL BE BRAND NEW AND OF THE
APPROVED TYPE FOR THE LOCATION AND PURPOSE.
7. SOLAR CONTRACTOR SHALL PROVIDE FINAL QUANTITY AND RATING OF SOLAR
PANEL (PHOTOVOLTAIC PANEL), SOLAR CHARGE CONTROLLERS, BATTERIES,
MINIMUM REINFORCING LAP SPLICE AND BEND AND INVERTERS BASED ON ACTUAL ROOF AND SITE ORIENTATION AND SPACES
A OR G HOOK 8. SOLAR CONTRACTOR SHALL PROVIDE FINAL DRAWINGS, SHOP SPECIFICATIONS
BAR LAP BEND Ø A OR G AND OTHER RELATED DOCUMENTS FOR SOLAR POWER SYSTEM
SIZE (cm) (mm) 180° 90° DETAILING
DIMENSIONS 9. DESIGN OF DISTRIBUTION SYSTEM IS NOT INCLUDED IN THIS STANDARD PLAN
D10 30 57 13 13 AS IT VARIES DEPENDING ON THE SITE LOCATION.
180°
D12 45 76 15 18 BEND 10. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
18 23 D
SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER.
D16 53 95
D20 61 114 20 25 DETAILING
DIMENSIONS A OR G
D25 76 152 25 36
31 41 90°
D28 91 229
BEND
D32 99 260 33 46 D
D36 114 285 36 51

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan GENERAL NOTES REPUBLIC OF THE PHILIPINES JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS 2
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
GREEN BUILDERS PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
PROJECT ENGINEER ENGINEER II
OIC-CHIEF, CONSTRUCTION SECTION
CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
2 13
KALIBO, AKLAN TOTING REYES ST. KALIBO, AKLAN
DATE: DATE: DATE: DATE: DATE:
DATE: BALETE, AKLAN
LIGHT GAGE STEEL PURLIN
1" x 12" FASCIA BD. 100x60x2.5mm
SPACED @ 700mm O.C.

LONG BEAM

CROSS BEAM
A36 TUBULAR
RAFTER
90x90x2.5mm

3 ROOF FRAMING PLAN


SCALE: 1:80m
2400 800
1200

2100
WOOD WINDOW WOOD FLUSH
900

JALOUSIE DOOR

W-1
D-1

10 DOOR & WINDOWS SCHEDULE


SCALE: 1:50m

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan ROOF FRAMING & DOORS & WINDOWS REPUBLIC OF THE PHILIPINES 3
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
DATE:
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION
DATE:
CHIEF, PLANNING AND DESIGN SECTION
DATE:
OIC-ASSISTANT DISTRICT ENGINEER
DATE: DATE:
DISTRICT ENGINEER 3 13
DATE: BALETE, AKLAN
6600

FLOW

PV MODULE
CONTROL PANEL
MODULE RAIL
7600

RIB TYPE COLOR STEEL


ROOF PURLIN
TABLE ROOF RAFTER

2 ON ROOF PV SOLAR PANEL CONNECTION


SCALE: 1:75m

1 ON ROOF PV SOLAR PANEL PLAN


SCALE: 1:75m
MID CLAMP
MODULE RAIL

PV MODULE
M8 ALLEN SCREW PV MODULE M8 ALLEN SCREW
L-FEET

HANGER BOLT

END CLAMP COLOR STEEL


M8 ALLEN SCREW
MODULE RAIL MODULE RAIL

ROOF PURLIN
Detail "2" Detail"3"
Detail "1"
END CLAMP
MODULE RAIL RAIL SPLICE
PV MODULE
M8 ALLEN SCREW

M8 ALLEN SCREW

MODULE RAIL

ALLEN SCREW
HANGER BOLT
L-FEET

Detail "Rail Splice"


Detail "4"
3 MOUNTING BRACKET DETAILS
SCALE: 1:100m

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan ROOFING MOUNTING DETAILS REPUBLIC OF THE PHILIPINES
4
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER 4 12
DATE: BALETE, AKLAN DATE: DATE: DATE: DATE: DATE:
150
4000
150 150

4000 Ø10 mm. HOR. BAR


@3 LAYER OF 0.15m.
CHB
800

W-1 WF - 1
Ø10 mm. VERT. BAR
@0.80M O.C.
C1 F1 C1 F1

NGL
CONTROL PANEL

4000
4000

WF - 1
WF - 1
2-Ø10mm BARS
100mm THK SOG

250 400
Ø10mm LONG BARS
W/ Ø10mm BAR
TABLE
@ 300mm O.C.
E.W.
WF-1

C1 F1 C1 F1
D-1
800

W-1 1-Ø10mm LATERAL 900

TIES 1@50mm, 4-Ø16mm MAIN BAR


10@75mm,
REST @150mm
FLOOR PLAN FOUNDATION PLAN

900

250
1 2
SCALE: 1:80m SCALE: 1:80m
250

NGL

600
9-Ø12mm E.W.
3740

300
C1 F1

W-1
D-1
SLOTTED CONCRETE
BLOCK (0.20 x 0.30)
FOOTING-COLUMN
DETAIL
100

4
SCALE: 1:50m
6 FRONT ELEVATION 7 RIGHT SIDE ELEVATION
SCALE: 1:80m SCALE: 1:80m

200
STD G.I. GUTTER
FASCIA BOARD 4-Ø16mm MAIN BAR
3740

300
1-Ø10mm STIRRUP
1@50mm,
4" Ø PVC 10@70mm,
DOWN SPOUT REST @120mm
W-1

BEAM DETAIL
100

5
SCALE: 1:50m
8 REAR ELEVATION 9 LEFT SIDE ELEVATION
NOTE: THE PROVIDED POWER HOUSE DIMENSIONS ARE JUST THE MINIMUM.
SCALE: 1:80m SCALE: 1:80m DIMENSIONS MAY VARY BASED ON THE ACTUAL LOT AREA.
SIZES OF FOOTING AND OTHER STRUCTURAL MEMBERS SHOULD BE SUPPORTED
BY STRUCTURAL ANALYSIS BASED ON GEOTECHNICAL INVESTIGATION REPORT.

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan PUMP HOUSE DETAILS
REPUBLIC OF THE PHILIPINES 5
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
DATE:
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION
DATE:
CHIEF, PLANNING AND DESIGN SECTION
DATE:
OIC-ASSISTANT DISTRICT ENGINEER
DATE: DATE:
DISTRICT ENGINEER 5 13
DATE: BALETE, AKLAN
LEGEND:
A - AUTOMATIC AC CIRCUIT BREAKER
20AF, 2P, 240 VOLTS, 15AT - LITHIUM-ION BATTERY OR APPROVED EQUAL SCHEDULES OF WIRES IN CONDUIT 5000
IN NEMA 1 ENCLOSURE

B - AUTOMATIC AC CIRCUIT BREAKER - MANUAL TRANSFER SWITCH X0 2- 3.5 mm² THHN IN 15mm Ø PVC.

800
225AF, 2P, 240 VOLTS, 125AT
IN NEMA 1 ENCLOSURE X1 1- 50 mm² PV CABLE

C - AUTOMATIC DC CIRCUIT BREAKER


- 5HP, 1Ø, 230V, 60Hz., AC, SUBMERSIBLE PUMP MOTOR
X2 1 - 60 mm² PV CABLE
A
225AF, 2P, 240 VOLTS, 150AT
1
IN NEMA 1 ENCLOSURE 1 - ONE (1) - 18W, 230V, T5 LED TUBE & BOX TYPE SET X3 2 - 30 mm² THHN + 1-8.0mm² THHN (G) IN 40mm Ø RSC. b TAPPED TO PURE

4000
D - AUTOMATIC DC CIRCUIT BREAKER X0 SINE WAVE
400AF, 2P, 240 VOLTS, 300AT - ONE (1) - 20W, 230V, LED FLOODLIGHT INVERTER
IN NEMA 1 ENCLOSURE 1
a
- DUPLEX CONVENIENCE OUTLET, GROUNDING TYPE
(20AMPS, 250VOLTS)
-550W SOLAR MONOCRYSTALLINE S³abc
PANELS OR APPROVED EQUAL S³abc - 3 SINGLE-POLE WALL SWITCHES ON ONE SWITCH PLATE

800
(10AMPS, 250VOLTS) c

- SOLAR CHARGE CONTROLLER


(MAXIMUM POWER POINT TRACKING) OR
APPROVED EQUAL
1 POWER HOUSE LIGHTING LAYOUT
HYBRID INVERTER OR
APPROVED EQUAL SCALE: 1:100m

PROVISION FOR NORMAL


SUPPLY, GENERATING SET OR
5 STRINGS OF 4, 550W SOLAR MONOCYRSTALLINE PANELS OTHER RENEWABLE ENERGY
SOURCE
1-300Ah LI-ION
BATTERIES OR
APPROVED
EQUIVALENT 15kW
225A

DC DC DC AC AC
X1 X1 X1 X1 X2 X2 X3 X3
C D D B B
MPPT

HYBRID INVERTER

PROVISION:
ENCLOSED MANUAL
PROPOSED: 5HP, 1Ø,
TRANSFER SWITCH:
230V, 60Hz., AC,
BREAKER TYPE,
SUBMERSIBLE PUMP
125AMPS, 2P, 230V,
MOTOR
10kAIC, NEMA 1

1 SINGLE LINE DIAGRAM


SCALE: NTS

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan SOLAR POWER SINGLE DIAGRAM REPUBLIC OF THE PHILIPINES
6
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER 6 13
DATE: BALETE, AKLAN DATE: DATE: DATE: DATE: DATE:
4" Ø DOUBLE
4" Ø AIR VENT PIPE P.E. FLANGE INLET
LIFTING LUGS

4" Ø DOUBLE FLANGE


OVERFLOW
4" Ø DOUBLE
FLANGE INLET

2850
2850
EXTERNAL LADDER

LEVEL INDICATOR
4" Ø DOUBLE 4"Ø DOUBLE
FLANGE OUTLET FLANGE OUTLET
4"Ø DOUBLE
FLANGE DRAIN

150
150
TANK STRAPPING

TANK FITTINGS DETAILS TANK PERSPECTIVE PLAN


SCALE: NTS SCALE: NTS

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan WATER TANK DETAILS REPUBLIC OF THE PHILIPINES 7
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
DATE:
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION
DATE:
CHIEF, PLANNING AND DESIGN SECTION
DATE:
OIC-ASSISTANT DISTRICT ENGINEER
DATE: DATE:
DISTRICT ENGINEER 7 13
DATE: BALETE, AKLAN
PROPOSED WATER TANK 15 cum. Capacity INLET 4" ØDOUBLE FLANGE

PROPOSED WATER TANK 15 cum. Capacity


Inlet 50mmΦ Inlet 50mmΦ
OVERFLOW FLANGE 4" Ø

G.I.SCH.40 50mmØ

2850
OUTLET 4" Ø DOUBLE FLANGE

400

7250
G.I. SCH. 40 32mmØ

DETACHABLE LADDER

4000
G.I. Sch. 40 50mmØ

Thrust Block
GATEVALVE 50mmØ GATEVALVE 50mmØ

400
N.G.L.
N.G.L.
To Distribution Line

FROM SOURCE

500

OUTLET AND INLET PLAN


SCALE NTS
LADDER DETAILS
SCALE NTS

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan OUTLET AND INLET PLAN
LADDER DETAILS
REPUBLIC OF THE PHILIPINES
8
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER 8 13
DATE: BALETE, AKLAN DATE: DATE: DATE: DATE: DATE:
3000
4250

625 3000 625

B-2 C' B-2

625
C' C'
C1-F1 C1-F1
GTB
B-1

B-2

B-2
1
B-

B-
1
3000

4250

3000
GTB GTB
C' B-1 Water Tank B-1 C'

B-
B-

1
B-2

B-2
B-1
C1-F1 C1-F1

625
C' C'
B-2 C' B-2

FRAMING PLAN
SCALE 1:20
FOUNDATION PLAN
SCALE 1:20

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan FRAMING AND FOUNDATION PLAN REPUBLIC OF THE PHILIPINES 9
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
DATE:
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION
DATE:
CHIEF, PLANNING AND DESIGN SECTION
DATE:
OIC-ASSISTANT DISTRICT ENGINEER
DATE: DATE:
DISTRICT ENGINEER 9 13
DATE: BALETE, AKLAN
27- 16MM Ø MATT BARS
SPACE EQUALLY ON Y-AXIS

8 - 20MM Ø VERT. BARS TIED


WITH 10MM Ø TIES 5@ 50MM,
5 @ 100MM, REST @ 150MM

575

575
50
C-1 C-1 50

50

50
300

300
GTB

34 - 16MM Ø MATT BARS


SPACE EQUALLY ON Y-AXIS
GTB

GTB
4250

4250
2700

1500
8 - 20MM Ø VERT. BARS TIED
WITH 10MM Ø TIES 5@ 50MM, 4 - 16MM Ø VERT. BARS TIED
5 @ 100MM, REST @ 150MM WITH 10MM Ø TIES 5@ 50MM,
REST @ 100MM
300
150

300

150
50 50
50

50
300

300
GTB
C-1 C-1
C-1 C-1
CF SECTION & PLAN
575

575
SCALE 1:20m

575 300 2700 300 575

4250

CF SECTION & PLAN


SCALE 1:20m

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan CF SECTION AND PLAN REPUBLIC OF THE PHILIPINES
10
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
DATE:
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION
DATE:
CHIEF, PLANNING AND DESIGN SECTION
DATE:
OIC-ASSISTANT DISTRICT ENGINEER
DATE: DATE:
DISTRICT ENGINEER 10 13
DATE: BALETE, AKLAN
FOOTING SCHEDULE
REINFORCEMENT
MATERIAL PROPERTIES: f'c = 20.70 MPa & fy = 275 MPa
FOOTING
MARK
FOOTING DIMENSION (m) MATTING
REMARKS
Width Length Thickness Depth X-AXIS Y-AXIS

F1 2.00 2.00 0.30 1.50 14 - 16mm ∅ 14 - 16mm ∅ ISOLATED

NOTE:
1.) DEPTH OF EXCAVATION MUST BE BASED ON THE ORIGINAL GROUND LEVEL AND NOT ON FILL.

FOOTING TIE BEAM


SCHEDULE OF BEAM REINFORCEMENT
BEAM SECTION MATERIAL PROPERTIES: f'c = 20.70 MPa & fy = 275 MPa
BEAM BAR STIRRUPS
WIDTH DEPTH SUPPORT MIDSPAN MIDDLE
MARK SIZE 10 mm DIA.
BAR
B (mm) D (mm) (mm) TOP BOTTOM TOP BOTTOM
5@50mm, 5@100mm, REST @150mm @
GTB 250 400 16 5 - 16mm 3 - 16mm 5 - 16mm 3 - 16mm MIDSPAN

SECOND FLOOR BEAM SCHEDULE


SCHEDULE OF BEAM REINFORCEMENT
BEAM SECTION MATERIAL PROPERTIES F'c = 20.70 MPa & Fy = 275 MPa
BEAM BAR STIRRUPS
WIDTH DEPTH SUPPORT MIDSPAN MIDDLE
MARK SIZE 10 mm DIA.
BAR
B (mm) D (mm) (mm) TOP BOTTOM TOP BOTTOM
5@50mm, 5@100mm, REST @150mm @
B-1 250 400 20 5 - 20mm 3 - 20mm 5 - 20mm 3 - 20mm 2-12mm
MIDSPAN
5@50mm, 5@100mm, REST @150mm @
B-2 200 400 16 2 - 16mm 2 - 16mm 2 - 16mm 2 - 16mm 2-12mm
MIDSPAN

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan FOOTING AND BEAM SCHEDULE REPUBLIC OF THE PHILIPINES
11
GREEN BUILDERS DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS
KALIBO, AKLAN PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
TOTING REYES ST. KALIBO, AKLAN
PROJECT ENGINEER OIC-CHIEF, CONSTRUCTION SECTION CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER 11 13
DATE: BALETE, AKLAN DATE: DATE: DATE: DATE: DATE:
SLEEVE TYPE COUPLING WITH
HARNESS SET
PIPE SUPPORT
FLOWMETER (SEE SPECS.)
13 mm AIR RELIEF ASSY.

CHECK VALVE
PRESSURE SWITCH GAUGE/
TRANSMITTER ASSY.
SEE SPECS.

BUTTERFLY VALVE WITH HANDWHEEL


SLEEVE TYPE COUPLING WITH TEE
HARNESS SET,SEE STD.DWG. MD-103
19mm O HOSE BIBB
4-PCS. 45° LR BEND
TEE SUPPORT
SEE LWUA STD.DETAIL

4-PCS. 45° LR BEND CONCRETE PUMP BASE


SEE PUMP MANUFACTURER'S
TRANSMISSION PIPE RECOMMENDATION

DISTRIBUTION PIPE

REDUCER
CONCRETE THRUST BLOCK

MECHANICAL LAYOUT PLAN


SCALE NTS

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan MECHANICAL PLAN LAYOUT REPUBLIC OF THE PHILIPINES JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS 12
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
GREEN BUILDERS PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
PROJECT ENGINEER ENGINEER II
OIC-CHIEF, CONSTRUCTION SECTION
CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
12 13
KALIBO, AKLAN TOTING REYES ST. KALIBO, AKLAN
DATE: DATE: DATE: DATE: DATE:
DATE: BALETE, AKLAN
GROUND PROFILE
SCALE NTS
RESISTIVITY RESULT
SCALE NTS

PREPARED: PROJECT NAME AND LOCATION SHEET CONTENT CHECKED: SUBMITTED: REVIEWED: RECOMMENDED: APPROVED: SHEET NO.

Construction of Solar Water System,


Brgy. Aranas, Balete, Aklan
GROUNDWATER RESISTIVITY RESULT
REPUBLIC OF THE PHILIPINES JOHN ROLAND E. ISTURIS JEROLD P. SENATIN ERNAN I. BAÑES LEVINA C. AMAR GENER J. ABERGAS 1
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
GREEN BUILDERS PROJECT MANAGER
REGION VI
AKLAN DISTRICT ENGINEERING OFFICE
PROJECT ENGINEER ENGINEER II
OIC-CHIEF, CONSTRUCTION SECTION
CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
13 13
KALIBO, AKLAN TOTING REYES ST. KALIBO, AKLAN
DATE: DATE: DATE: DATE: DATE:
DATE: BALETE, AKLAN

You might also like