Customer : AVTEC LIMITED

Part No. : TP8024Z


JKF Ref : 8464
Subject : Air leak in Yoke seal

J. K. Fenner India Limited <CONFIDENTIAL> 1


TRIMMING PROCESS –PHOTOS

Molded lip seal Trimmed lip seal Trimming process Photos

Excess Flash Removal Sealing Lip formed

Excess Flash Sealing Lip


Removal profile Formed Profile

Sealing Lip forming from mold Seal Lip formed from


& Excess Flash removed from machining,
tool Reason : In Previous Air Leak
Failure Addressed

2
J. K. Fenner India Limited <CONFIDENTIAL>
ACRYLIC – SHAFT LIP PHOTOS

Helix Contact Photo for Proto Cavity Sample Helix Contact Photo for Multicavity Sample

In Proto cavity sample Only Contact Line visible , but helix not visible In Multicavity Sample, observed lip contact & helix Contact

3
J. K. Fenner India Limited <CONFIDENTIAL>
ACRYLIC – SHAFT LIP PHOTOS

Helix Contact Photo for Multicavity Helix Contact Photo for Multicavity Sample
Sample(Trimmed lip) ( Flash Trim)

In Multicavity Sample, observed lip contact & helix Contact In Multicavity Sample, observed lip contact & helix Contact

3
J. K. Fenner India Limited <CONFIDENTIAL>
AIR LEAK TEST CONDITION

Background: In Previous Multicavity Samples are tested in the below mentioned Specification
Filling pressure : 400 to 480 mbar

Filling Time : 5 Secs


As per the request from AVTEC specification changed to 700 mbar
Due this change in pressure Spring Tension increased to 0.3 N

Test method:
The seal was assembled in the test rig with the housing and shaft dimensions
Air Inlet
Hose
maintained as given below :
Shaft outer diameter, mm : 45.98 h7
Housing bore diameter, mm : 70.50 H8
Shaft finish : 0.26 Ra

After seal assembly in the rig the shaft is rotated manually for 3 to 5 rotations in
CCW direction. After 30min the test chamber was pressurised at 0.50,1.00, 1.2
Bar for 30 sec. Any leakage of air through the seal was noticed using a soap
solution

Sample No: 1 & 2 (0.50, 1.00, 1.2) Bar No air leakage was noticed from the seal lip

J. K. Fenner India Limited <CONFIDENTIAL>


PROFILE - COMPARISION

Molded lip seal Trimmed lip seal Super Imposed profile

J. K. Fenner India Limited <CONFIDENTIAL> 5


Yoke Side Seal Summary of Samples

1. As per Avtec requirement w/o removal of excess flash 50nos of sample given.
2. By Increasing Spring Tension (0.3 N) in Multicavity samples and as per the requirement of Avtec tested leak at 0.7 bar in JKF
Test rig Found OK. Given 50 no’s of Sample.
3. As per Avtec requirement Proto cavity samples given of quantity 400 no’s, Feedback Awaited.
4. In multicavity tool 20nos samples provided by excess flash removed from tool. Feedback Awaited.
1.On 08.01.2024, 40 no’s of seals provided with increased lip contact & trimming of flash done, in that 10 no’s assembled
infornt of JKF & Avtec- No Leak Found
2. In Avtec End,Filling Pressure Reduced from 0.7 bar to 0.4 bar.
3. After that 520 no’s Yoke side seal dispatched to Avtec, Out of 520 No’s-452 Asembbled in their line and not observed any
leakage feedback received from Avtec

4. Continuous monitoring will be done in next lot.

J. K. Fenner India Limited <CONFIDENTIAL>


Sample Seal Helix & Main lip contact Photos

Helix Contact Photo for Multicavity Helix Contact Photo for Multicavity
Sample(Trimmed lip) Sample(Trimmed lip)

In Multicavity Sample, observed lip contact 360° and Helix contact In Multicavity Sample, observed lip contact 360° and Helix
found ok contact found ok

3
J. K. Fenner India Limited <CONFIDENTIAL>
PROFILE - COMPARISION

Trimmed lip seal Before Trimmed lip seal After

Inner Diameter Dimension Inner Diameter Dimension

Unit of Unit of
ID Spec S1 S2 S3 S4 S5 ID Spec S1 S2 S3 S4 S5
Measure Measure
Ø44.00 / Ø44.00 /
mm 44.74 44.77 44.78 44.76 44.75 mm 44.57 44.54 44.5 44.52 44.56
Ø45.00 Ø45.00

J. K. Fenner India Limited <CONFIDENTIAL> 5


AIR LEAK TEST CONDITION

In Avtec changed the air leak Specification as per below:

Filling pressure : 0.4 to 0.5 bar

Filling Time : 30 Secs


Stabilizing Time : 30 Secs
Leak Time : 5 Secs
Leak rate : 40pa/4 secs

Further Dispatching Feb’24 Quantities ,assemble in Avtec line and Pl


provide Feedback…