Air Leak Analysis Report
Air Leak Analysis Report
Air Leak Analysis Report
2
J. K. Fenner India Limited <CONFIDENTIAL>
ACRYLIC – SHAFT LIP PHOTOS
Helix Contact Photo for Proto Cavity Sample Helix Contact Photo for Multicavity Sample
In Proto cavity sample Only Contact Line visible , but helix not visible In Multicavity Sample, observed lip contact & helix Contact
3
J. K. Fenner India Limited <CONFIDENTIAL>
ACRYLIC – SHAFT LIP PHOTOS
Helix Contact Photo for Multicavity Helix Contact Photo for Multicavity Sample
Sample(Trimmed lip) ( Flash Trim)
In Multicavity Sample, observed lip contact & helix Contact In Multicavity Sample, observed lip contact & helix Contact
3
J. K. Fenner India Limited <CONFIDENTIAL>
AIR LEAK TEST CONDITION
Background: In Previous Multicavity Samples are tested in the below mentioned Specification
Filling pressure : 400 to 480 mbar
Test method:
The seal was assembled in the test rig with the housing and shaft dimensions
Air Inlet
Hose
maintained as given below :
Shaft outer diameter, mm : 45.98 h7
Housing bore diameter, mm : 70.50 H8
Shaft finish : 0.26 Ra
After seal assembly in the rig the shaft is rotated manually for 3 to 5 rotations in
CCW direction. After 30min the test chamber was pressurised at 0.50,1.00, 1.2
Bar for 30 sec. Any leakage of air through the seal was noticed using a soap
solution
Sample No: 1 & 2 (0.50, 1.00, 1.2) Bar No air leakage was noticed from the seal lip
1. As per Avtec requirement w/o removal of excess flash 50nos of sample given.
2. By Increasing Spring Tension (0.3 N) in Multicavity samples and as per the requirement of Avtec tested leak at 0.7 bar in JKF
Test rig Found OK. Given 50 no’s of Sample.
3. As per Avtec requirement Proto cavity samples given of quantity 400 no’s, Feedback Awaited.
4. In multicavity tool 20nos samples provided by excess flash removed from tool. Feedback Awaited.
1.On 08.01.2024, 40 no’s of seals provided with increased lip contact & trimming of flash done, in that 10 no’s assembled
infornt of JKF & Avtec- No Leak Found
2. In Avtec End,Filling Pressure Reduced from 0.7 bar to 0.4 bar.
3. After that 520 no’s Yoke side seal dispatched to Avtec, Out of 520 No’s-452 Asembbled in their line and not observed any
leakage feedback received from Avtec
Helix Contact Photo for Multicavity Helix Contact Photo for Multicavity
Sample(Trimmed lip) Sample(Trimmed lip)
In Multicavity Sample, observed lip contact 360° and Helix contact In Multicavity Sample, observed lip contact 360° and Helix
found ok contact found ok
3
J. K. Fenner India Limited <CONFIDENTIAL>
PROFILE - COMPARISION
Unit of Unit of
ID Spec S1 S2 S3 S4 S5 ID Spec S1 S2 S3 S4 S5
Measure Measure
Ø44.00 / Ø44.00 /
mm 44.74 44.77 44.78 44.76 44.75 mm 44.57 44.54 44.5 44.52 44.56
Ø45.00 Ø45.00