Top Extra Bars Top Full Length Bars Top Extra Bars Top Full Length Bars

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SHEET - 05 OF 05 IMPORTANT CONSTRUCTION NOTES:

1) DO NOT SCALE THE DRAWING. ONLY WRITTEN DIMENSIONS ARE


TO BE FOLLOWED
( L1)/4 ( L1)/4 ( L2)/4 ( L2)/7
2) ALL DIMENSIONS ARE IN FEET AND INCHES UNLESS & OTHERWISE NOTED.
3) SAFE BEARING CAPACITY OF SOIL FOR DESIGN OF FOUNDATION HAS
BEEN ASSUMED TO BE 25T/SQ.m
TOP FULL LENGTH BARS TOP EXTRA BARS TOP FULL LENGTH BARS TOP EXTRA BARS 4) LAY OUT DRG. IS TO BE APPROVED BY THE ARCHITECT/ENGINEER
C INCHARGE BEFORE EXECUTION.
5) PROPOED DRG. IS FOR GROUND FLOOR+1 ONLY.
ONLY FOUNDATION IS DESIGN FOR G+1 STORIED.
6) WE ARE PROVIDING STRUCTURAL DRAWINGS ONLY TO OWNER/
CONTRACTOR'S/ARCHITECTS/ENGINEER-IN-CHARGE FOR THIS PROJECT.
D

SUPERVISION IS NOT OUR RESPONSIBILITY.


7) THE RESPONSIBILIYT OF ADHERING TO THE DRAWINGS ON SITE WILL BE
OF OWNER'S/ARCHITECT'S/CONTRACTOR'S/ENGINEER-IN-CHARGE AND
OFFICE WILL NOT BE RESPONSIBLE FOR ANY LAPSES IN THIS REGARD.
8) CHANGE IN DIMENSION OF ARCHITECTURAL DREAWING WILL CHANGE
BOTTOM FULL LENGTH BARS
CURTAIL BARS C BOTTOM FULL LENGTH BARS STRUCTURAL DRAWING IN THAT CONTEXT.

0.7(L1) 0.7(L2) COVER


9) UNLESS NOTED OTHERWISE CLEAR CONCRETE COVER TO MAIN
REINFORCEMENT SHALL BE AS FOLLOWS,
(L1) (L2) FOR MILD ENVORNMENTAL EXPOSURE CONDITION.
I) PILE CAP =50MM
ii) PILE = 40MM
LONGITUDINAL SECTION OF CONTINUOUS BEAM iii) COLUMN ABOVE PLINTH = 40MM
iv) SLAB = 25MM
v) BEAM = 30MM
(L2)/4 10) HOOK FOR 10 TIMES DIAMETER OF STIRRUPS.
1.5(L1) 11) L-BENT FOR COLUMN REINFORCEMENT TO BE 45MM
REINFORCING STEEL
FULL LENGTH BARS TOP EXTRA BARS
12) UNLESS NOTED OTHERWISE ALL REINFORCEMENT SHALL BE OF THERMO
MECHANICALLY TREATED BARS OF GRADE Fe 500 CONFIRMING
TO I.S: 1786 (LATEST)
13) ALL REINFORCING STEEL SHALL BE OF TASTED QUALITY.
CONCRETE
14) THIS STRUCTURE IS DESIGNED CONSIDERING “M20” GRADE OF CONCRETE.
D

GRADE OF CONCRETE FOR CASTING SHALL BE AS PER LATEST “IS-456” OR


AS PER EXECUTING AUTHORITY.
(FOR MILD ENVORNMENTAL EXPOSURE CONDITION AT SITE)
15) CONFIRMING TO I.S:456 (2000).
FULL LENGTH BARS CONSTRUCTION DETAILS
16) NOT MORE THAN 50% OF BARS SHALL BE LAP AT ANY SECTION.
LAP LENGTH SHALL BE PROVIDED IN STAGGERED MANNER.
17) ANY DISCREPANCY OR OMISSIONS SHALL BE BROUGHT TO
NOTICE BEFORE EXECUTION AND CONVEYED TO SITE.
(L1) (L2) SPECIAL NOTE:-
18) THIS DESIGN DRAWING IS FOR “MILD” ENVORNMENTAL EXPOSURE
CONDITION.
TYPICAL LONGITUDINAL SECTION OF CANTILEVER BEAM 19) EXECUTION OF WORK SHALL BE AS PER LATEST REVISION OF NATIONAL
BUILDING CODE AND IS 456.
20) LEVELING COURSE SHALL BE AS PER IS SPECIFICATION.
21) THIS DRAWING IS SUBJECTED TO PROPER MODIFICATION IF THERE
IS A REVISION IN THE FOLLOWING INDIAN STANDARD CODES OF
TYPICAL STAIRCASE SECTION 0
PRACTICES.
60 i) I.S. 456(2000), ii) I.S. 875-ALL PARTS (1987)
iii) I.S. 1893(2002), iv) I.S. 13920(1993)
v) I.S. 4326(1994).

DEVELOPMENT LENGTH AND LAP LENGTH TABLE


MB1
DIA OF BAR DEV. LENGTH (Ld)
MAIN STEEL 8 mm TOR 480 mm
10 Ø @ 125 c/c
600 10 mm TOR 600 mm
DISTRIBUTION STEEL
12 mm TOR 720 mm
8 Ø @ 150 c/c 16 mm TOR 960 mm
20 mm TOR 1200 mm
WAIST SLAB
125 THK.
CONTRACTOR AGENCY:- VISHWA
STRUCTURAL CONSULTANTS
PB
DESIGNED BY : Er. VINAYAK T. GUNDLA
B.E.(Civil) , M.Tech. (Structures)
MOBILE NO. : 9890571845
(L1)/4 (L1)/4 (L2)/4 EMAIL ID : vishwastructures04@gmail.com

NAME OF WORK :-
D

CONSTRUCTION OF RESIDENTIAL BUNGLOW AT SOLAPUR.

(L1)/5 (L1)/5 (L2)/5 TITLE:- COLUMN BEAM AND SLAB SECTIONS.


(L2)/7
(L1) (L2) OWNER NAME: MR. RAKESH MHETRE

FIRST SUBMISSION DATE:- 22 / 03 /2024


TYPICAL SECTION OF BENT UP SLAB
SCALE - AS SHOWN SHEET NO . 05 / 05

You might also like