SHEET - 02 OF 05 IMPORTANT CONSTRUCTION NOTES:

1) DO NOT SCALE THE DRAWING. ONLY WRITTEN DIMENSIONS ARE


TO BE FOLLOWED
2) ALL DIMENSIONS ARE IN FEET AND INCHES UNLESS & OTHERWISE NOTED.
3) SAFE BEARING CAPACITY OF SOIL FOR DESIGN OF FOUNDATION HAS
BEEN ASSUMED TO BE 25T/SQ.m
4) LAY OUT DRG. IS TO BE APPROVED BY THE ARCHITECT/ENGINEER
INCHARGE BEFORE EXECUTION.
5) PROPOED DRG. IS FOR GROUND FLOOR+1 ONLY.
ONLY FOUNDATION IS DESIGN FOR G+1 STORIED.
B 6) WE ARE PROVIDING STRUCTURAL DRAWINGS ONLY TO OWNER/
CONTRACTOR'S/ARCHITECTS/ENGINEER-IN-CHARGE FOR THIS PROJECT.
SUPERVISION IS NOT OUR RESPONSIBILITY.
7) THE RESPONSIBILIYT OF ADHERING TO THE DRAWINGS ON SITE WILL BE
COLUMN CROSS SECTIONS FROM FOOTING TO PLINTH OF OWNER'S/ARCHITECT'S/CONTRACTOR'S/ENGINEER-IN-CHARGE AND
OFFICE WILL NOT BE RESPONSIBLE FOR ANY LAPSES IN THIS REGARD.
COLUMN CROSS SECTIONS C1,C2,C4,C5,C6,C7,C9. 8) CHANGE IN DIMENSION OF ARCHITECTURAL DREAWING WILL CHANGE
8 -12Ø C10,C11,C12. 8 -12Ø STRUCTURAL DRAWING IN THAT CONTEXT.
3"

3"
COVER
8Ø 4"c/c 8Ø 4"c/c 9) UNLESS NOTED OTHERWISE CLEAR CONCRETE COVER TO MAIN
15"

15"
REINFORCEMENT SHALL BE AS FOLLOWS,
FOR MILD ENVORNMENTAL EXPOSURE CONDITION.
FLOOR BEAM I) PILE CAP =50MM
ii) PILE = 40MM
9" 9" iii) COLUMN ABOVE PLINTH = 40MM
DOUBLE LINKS DOUBLE LINKS
A A iv) SLAB = 25MM

L0
2'
AT TOP & BOTTOM AT CENTRE v) BEAM = 30MM
10) HOOK FOR 10 TIMES DIAMETER OF STIRRUPS.
SECTION A-A SECTION B-B
11) L-BENT FOR COLUMN REINFORCEMENT TO BE 45MM
COLUMN CROSS SECTIONS FOR C3,C8,C13. REINFORCING STEEL
12) UNLESS NOTED OTHERWISE ALL REINFORCEMENT SHALL BE OF THERMO
8 -12Ø 8 -12Ø B B MECHANICALLY TREATED BARS OF GRADE Fe 500 CONFIRMING
3"

3"
TO I.S: 1786 (LATEST)
13) ALL REINFORCING STEEL SHALL BE OF TASTED QUALITY.
8Ø 4"c/c 8Ø 4"c/c CONCRETE
18"

18" 14) THIS STRUCTURE IS DESIGNED CONSIDERING “M20” GRADE OF CONCRETE.


GRADE OF CONCRETE FOR CASTING SHALL BE AS PER LATEST “IS-456” OR

L1
AS PER EXECUTING AUTHORITY.
(FOR MILD ENVORNMENTAL EXPOSURE CONDITION AT SITE)
9" DOUBLE LINKS 9" DOUBLE LINKS
(57Ø) 15) CONFIRMING TO I.S:456 (2000).
CONSTRUCTION DETAILS
AT TOP & BOTTOM AT CENTER
16) NOT MORE THAN 50% OF BARS SHALL BE LAP AT ANY SECTION.
SECTION A-A SECTION B-B
LAP LENGTH SHALL BE PROVIDED IN STAGGERED MANNER.
17) ANY DISCREPANCY OR OMISSIONS SHALL BE BROUGHT TO
NOTICE BEFORE EXECUTION AND CONVEYED TO SITE.
SPECIAL NOTE:-
COLUMN CROSS SECTIONS FROM PLINTH TO FIRST SLAB
A A 18) THIS DESIGN DRAWING IS FOR “MILD” ENVORNMENTAL EXPOSURE

L0
'
2
COLUMN CROSS SECTIONS C1,C2,C4,C5,C6,C7,C9. CONDITION.
8 -12Ø C10,C11,C12. 8 -12Ø 19) EXECUTION OF WORK SHALL BE AS PER LATEST REVISION OF NATIONAL
BUILDING CODE AND IS 456.
3"

3"

20) LEVELING COURSE SHALL BE AS PER IS SPECIFICATION.


21) THIS DRAWING IS SUBJECTED TO PROPER MODIFICATION IF THERE
8Ø 4"c/c 8Ø 8"c/c IS A REVISION IN THE FOLLOWING INDIAN STANDARD CODES OF
15"

15"

PRACTICES.
i) I.S. 456(2000), ii) I.S. 875-ALL PARTS (1987)
G.L. PLINTH BEAM
iii) I.S. 1893(2002), iv) I.S. 13920(1993)
v) I.S. 4326(1994).
9" DOUBLE LINKS 9" DOUBLE LINKS
DEVELOPMENT LENGTH AND LAP LENGTH TABLE
AT TOP & BOTTOM AT CENTRE
SECTION A-A SECTION B-B DIA OF BAR DEV. LENGTH (Ld)
8 mm TOR 480 mm
UP TO HARD STRATA

COLUMN CROSS SECTIONS FOR C3,C8,C13.


10 mm TOR 600 mm
8 -12Ø 8 -12Ø 12 mm TOR 720 mm
16 mm TOR 960 mm
3"

3"

20 mm TOR 1200 mm
8Ø 4"c/c 8Ø 8"c/c
CONTRACTOR AGENCY:- VISHWA
18"

18"

STRUCTURAL CONSULTANTS

DESIGNED BY : Er. VINAYAK T. GUNDLA


9" DOUBLE LINKS 9" DOUBLE LINKS B.E.(Civil) , M.Tech. (Structures)
FOOTING MOBILE NO. : 9890571845
D

AT TOP & BOTTOM AT CENTER 300 EMAIL ID : vishwastructures04@gmail.com


SECTION A-A SECTION B-B
4" THK.P.C.C. BED
NAME OF WORK :-

TYPICAL LONGITUDUNAL SECTION OF COLUMN


CONSTRUCTION OF RESIDENTIAL BUNGLOW AT SOLAPUR.

TITLE:- R.C.C. DETAILS FOR COLUMN CROSS SECTION

OWNER NAME: MR. RAKESH MHETRE

FIRST SUBMISSION DATE:- 22 / 03 /2024


SCALE - AS SHOWN SHEET NO . 02 / 05