Professional Documents
Culture Documents
Column Cross Sections From Footing To Plinth: Floor Beam
Column Cross Sections From Footing To Plinth: Floor Beam
3"
COVER
8Ø 4"c/c 8Ø 4"c/c 9) UNLESS NOTED OTHERWISE CLEAR CONCRETE COVER TO MAIN
15"
15"
REINFORCEMENT SHALL BE AS FOLLOWS,
FOR MILD ENVORNMENTAL EXPOSURE CONDITION.
FLOOR BEAM I) PILE CAP =50MM
ii) PILE = 40MM
9" 9" iii) COLUMN ABOVE PLINTH = 40MM
DOUBLE LINKS DOUBLE LINKS
A A iv) SLAB = 25MM
L0
2'
AT TOP & BOTTOM AT CENTRE v) BEAM = 30MM
10) HOOK FOR 10 TIMES DIAMETER OF STIRRUPS.
SECTION A-A SECTION B-B
11) L-BENT FOR COLUMN REINFORCEMENT TO BE 45MM
COLUMN CROSS SECTIONS FOR C3,C8,C13. REINFORCING STEEL
12) UNLESS NOTED OTHERWISE ALL REINFORCEMENT SHALL BE OF THERMO
8 -12Ø 8 -12Ø B B MECHANICALLY TREATED BARS OF GRADE Fe 500 CONFIRMING
3"
3"
TO I.S: 1786 (LATEST)
13) ALL REINFORCING STEEL SHALL BE OF TASTED QUALITY.
8Ø 4"c/c 8Ø 4"c/c CONCRETE
18"
L1
AS PER EXECUTING AUTHORITY.
(FOR MILD ENVORNMENTAL EXPOSURE CONDITION AT SITE)
9" DOUBLE LINKS 9" DOUBLE LINKS
(57Ø) 15) CONFIRMING TO I.S:456 (2000).
CONSTRUCTION DETAILS
AT TOP & BOTTOM AT CENTER
16) NOT MORE THAN 50% OF BARS SHALL BE LAP AT ANY SECTION.
SECTION A-A SECTION B-B
LAP LENGTH SHALL BE PROVIDED IN STAGGERED MANNER.
17) ANY DISCREPANCY OR OMISSIONS SHALL BE BROUGHT TO
NOTICE BEFORE EXECUTION AND CONVEYED TO SITE.
SPECIAL NOTE:-
COLUMN CROSS SECTIONS FROM PLINTH TO FIRST SLAB
A A 18) THIS DESIGN DRAWING IS FOR “MILD” ENVORNMENTAL EXPOSURE
L0
'
2
COLUMN CROSS SECTIONS C1,C2,C4,C5,C6,C7,C9. CONDITION.
8 -12Ø C10,C11,C12. 8 -12Ø 19) EXECUTION OF WORK SHALL BE AS PER LATEST REVISION OF NATIONAL
BUILDING CODE AND IS 456.
3"
3"
15"
PRACTICES.
i) I.S. 456(2000), ii) I.S. 875-ALL PARTS (1987)
G.L. PLINTH BEAM
iii) I.S. 1893(2002), iv) I.S. 13920(1993)
v) I.S. 4326(1994).
9" DOUBLE LINKS 9" DOUBLE LINKS
DEVELOPMENT LENGTH AND LAP LENGTH TABLE
AT TOP & BOTTOM AT CENTRE
SECTION A-A SECTION B-B DIA OF BAR DEV. LENGTH (Ld)
8 mm TOR 480 mm
UP TO HARD STRATA
3"
20 mm TOR 1200 mm
8Ø 4"c/c 8Ø 8"c/c
CONTRACTOR AGENCY:- VISHWA
18"
18"
STRUCTURAL CONSULTANTS