Web force measurement with electronic amplifier CV 2201
1. General
Instructions
1.1 Key to symbols performing operations
important additional information and remarks
sections worthy of special note to guarantee safe operation
of the amplifier CV 2201.
1.2 Description Look after this description carefully and make sure it is available to
the personnel at all times.
This description is integral part of the delivery. It should be read care-
fully before performing any job whatsoever on the equipment, be it
for mounting, operating or maintenance.
All activities and jobs may be performed by specialized personnel
only or by personnel especially trained for that purpose.
1.3 Safety instructions Never insert your hand or tools between turning rollers.
2. Function Amplifier CV 2201 is an integral part of the E+L web force measur-
ing unit. It amplifies the signal voltage emitted by the PD 2... load cell
(maximum two cells), the magnitude of which changes in proportion
to the web force.
Input signals from 0 to ±20 mV are amplified to an output signal of
0 to ±10 V (0 to 20 mA or 4 to 20 mA).
Only use amplifier CV 2201
- when in a perfect technical condition
- according to its intended usage,
- in compliance with the description.
Page 2
Web force measurement with electronic amplifier CV 2201
Potentiometer R 40
Page 3
Web force measurement with electronic amplifier CV 2201
Reference voltage
Amplification
S 10
R 41
R 42
R 43
Amplification range S 11
Amplifier CV 2201, front view Connect a digital voltmeter with a measuring range of 15 V DC to
the terminals for the output voltage Udirect
Set the amplification range switch (S 11) to position "2". See figure
above.
R 41 Rough tare
compensation Then compensate the tare of the amplifier. This is to eliminate
R 42 Precision tare comp. external interferences which might influence the measuring
R 43 Amplification result, for example the roller weight.
There is still no web on the measuring roller. Using the potentio-
meters (R 41) for rough and (R 42) for fine adjustments, set the
output voltage as near as possible to 0.0 V or at least to less than
0.05 V.
5.1 Calibrating the amplifier The amplifier may be calibrated with or without a test weight.
CV 2201 We suggest using a test weight as the results are much more
precise.
Calibration without a test weight is impossible in conjunction
with safety barriers or load cells type PD 15.. and PD 25.. .
The resultant web force in the measuring direction should not exceed
by much the nominal measuring force of the load cell to make sure
that the individual load cells still operate within the linear range when
web force distribution is asymmetrical.
Page 4
Web force measurement with electronic amplifier CV 2201
5.1.1 Setting amplification with Ascertain the maximum web force. The later has been determined
a test weight at the project planning stage. If not, it must be ascertained empiri-
cally.
Place a strip of material over the measuring roller in the way the
web will lie afterwards (see fig. on left). Attach a test weight to the
Material strip of material representing the max. web force expected.
Measuring
roller Now measure the signal voltage of the load cell at the input of the
amplifier.
If the signal voltage of the load cell is greater than 15 mV, the
load cell is overloaded. Either change the angle of wrap or the
measuring direction.
Amplifier Set amplification using the "amplification" potentiometer (R 43).
CV 2201 Test See figure page 4. Turn to the right to increase the factor of ampli-
weight
fication
Calibrating the amplifier If the test weight is equivalent of the maximum web force, the sig-
nal voltage of the load cell must be amplified to an output voltage
Udirect of 10 V.
If a smaller test weight is used, the output voltage must accord-
ingly be lower.
Example:
If the maximum web force to be measured is 1000 N and if the
test weight acting on the measuring roller has 750 N, the output
voltage Udirect must be 7.5 V.
The corresponding equation is:
Page 5
Web force measurement with electronic amplifier CV 2201
Web force F
F1 = F x cos α
F2 = F x cos β
FR = F1 + F2 F
FR
α
Measuring direction
F2 F1 F2
FN
V= x 1000
FR β
Then calculate the output voltage Udirect using the following equa-
tion:
Udirect = output voltage (V)
FN FN = nominal measuring force (N), specified on
Udirect = x 10 V load cells, when measuring on two sides,
FR add both nominal measuring forces
FR = resultant web force (N)
5.2 Amplifier CV 2201 outputs The web force is available in three different signal forms:
- direct output Udirect (0 to ±10 V/10 mA, rise time 5 ms)
The direct output is used for the rapid acquisition of measured
values and for downstream control loops.
- filter output Ufilter (0 to ±10 V/10 mA)
The filter output may be used for display instruments.
Page 6
Web force measurement with electronic amplifier CV 2201
Current output
Filtered
output voltage Ufilter
Output current I
Operating voltage 24 V DC
Page 7