REVISION INDEX
1 Scope .............................................................................................................................................................4
2 General ..........................................................................................................................................................4
2.1 Tank sketch ...............................................................................................................................................5
7 Nozzle 3N – 4“dia Boil-off return to tank, Nozzle 4N – 8” dia Boil-off vapor to compressor ..................20
7.1 Self-weight + nozzle load .......................................................................................................................21
This document describes the mechanical design of roof nozzles 1N, 3N, 4N, 8N, 10N due to
external pipe loading for a double wall, double bottom, single containment tank as per API 620
Appendix Q to store 30750m³ liquefied ethylene.
The stress analysis of roof nozzle with associated tank roof structure will be performed by
“ANSYS” FEM – Program, of which a description is enclosed at the end of this document.
2 General
The tank is of double wall type with stiffened dome roof and internal suspended deck and shall
meet the requirements of API 620 App. Q.
The inner tank containing the cold product consists of a flat inner bottom with a cylindrical,
vertical open top shell. This open top inner tank is located within an outer tank consisting of a
flat outer bottom with a cylindrical, vertical outer shell with a stiffened dome roof and
suspended deck.
The inner tank will be anchored by straps in order to be stable against seismic loads.
The outer tank primarily contains the insulation and the warm product vapours. The outer tank is
not designed to hold the liquid in case of an inner tank failure.
The outer tank will be anchored by straps in order to be stable against seismic loads and internal
gas pressure.
The inner tank will be tested by hydrostatic water height in combination with a pneumatic test of
the outer tank as per API 620 App. Q.
2.1 Tank sketch
3 Summary of Most Significant Tank Design Data
Tank Design Code API 620 with Appendix Q & L, Tenth Edition, February 2002,
Addendum 1, June 2004
Product Ethylene
Geometrical Volume 32000 m³
Design Liquid level 28600 mm
Freeboard 1280 mm
Density, design 0.567
Internal Design Pressure, outer tank 100 mbarg
Test Air Pressure 125 mbarg
Test Water Height 27500 mm
Internal Design Vacuum -5 mbarg
Design Temperature, inner tank -106 °C
Design Temperature, outer tank ambient +55 °C
Insulation Thickness Bottom 300 mm Cellular Glass,
Shell annular space 800 mm expanded perlite with 150 mm
resilient blanket at inner shell, Suspended Deck 400 mm
Fibreglass / Mineral Wool
Corrosion Allowance, Inner Tank Nil
Corrosion Allowance, Outer Tank Roof plates only,1.5 mm
Liver loads Outer Roof: 1.2 kN/m² + 0.5 kN/m² snow =
1.7 kN/m² including internal vacuum,
Suspended Deck: 1.2 kN/m²,
Roof Platform: 5 kN/m²,
Walkways, Stairs: 2.5 kN/m²,
Design Wind Velocity Wind Pressure to be determined in accordance with UBC 1997
using
basic wind speed = 125 km/h at 10 meters above Grade,
importance factor I = 1.15, Exposure Category C
Earthquake Design Seismic Design Basis as advised by GACHSARAN with API 620
Appendix L, Zone 4, Soil Type S3, Height of Sloshing Wave as
per API 620 L.8.1
Max allowable Boil-Off Rate 0.1 Wt % per day,
max ambient temperature = 48°C, product temperature = -106°C
Pressure and Vacuum Protection Design and Sizing criteria as per
API 2000, fifth edition, April 1998.
Water Spray System Water supply pressure = 9.0 barg min required at tank bottom,
Water application rate = 3.0 litre/min m².
Feeding of cooling water via two vertical risers at shell and roof.
4 Tank Materials
Piping: stainless steel ASTM A312 TP304 Plates: A240 TP304
Operating:
Allowable primary membrane stress: S = 115 N/mm²
Allowable local membrane + bending stress: S = 1.5 x 115 = 173 N/mm²
Primary + secondary stress at discontinuities: 3 x 115 = 345 N/mm²
Operating + wind or earthquake:
Allowable primary membrane stress: 115 N/mm² x 1.2 = 138 N/mm²
Allowable local membrane + bending stress: S = 1.5 x 138 = 207 N/mm²
Primary + secondary stress at discontinuities: 3 x 138 = 414 N/mm²
5 Loadings
5.1 Self-weight
Self-weight is calculated by the program itself, taking in account the density and volume of material.
5.3 Earthquake
Earthquake load for the inner pipes is simplified by ground acceleration 0,4 g multiplied by the
importance factor of 1.25
The mass of the inner pipe fluid if exists is included in the calculation.
N3
pipe 114x 6.0/3.0
sleeve 356x9.5
pad 650x10
plate between pipe and sleeve: t=15
N4
pipe 219x8.2
sleeve 457x9.5
pad 800x10
plate between pipe and sleeve: t=15
pipe 219x8.2
sleeve 457x9.5
pad 800x10
plate between pipe and sleeve: t=15
The ANSYS program was introduced by Dr. John Swanson and Swanson Analysis Systems
Incorporated (SASI), in 1970. Since that time, the program, SASI and ANSYS Support
Distributors (ASDs) have grown as part of a commitment to provide the latest finite element
analysis and design technology to engineers worldwide. Today, ANSYS capabilities are
available on computers that range from PCs to super mainframes.
The ANSYS Program is a computer program for finite element analysis and design. You use the
program to find out how a given design (e.g. a machine component) works under operating
conditions. You can also use the ANSYS program to calculate the proper design for given
operating conditions.
The ANSYS program is a general-purpose program, meaning that you can use it for almost any
type of finite element analysis in virtually any industry -- automobiles, aerospace, railways,
machinery, electronics, sporting goods, power generation, power transmissions, and
biomechanics, to mention just a few.
“General purpose” also refers to the fact that the program can be used in all disciplines of
engineering -- structural, mechanical, electrical, electromagnetics, electronic, thermal, fluid and
biomedical. The ANSYS program is also used as an educational tool in universities and other
academic institutions.
ANSYS software is available on many types of computers - PCs (personal computers),
workstations, minicomputers, superminis, mainframes, super mainframes, etc. Several operating
systems are supported, as are a multitude of graphic devices.
Structural Analysis
Structural analysis is probably the most common application of the finite element method. The
term structural implies not only civil engineering structures such as bridges and buildings, but
also mechanical components such as pistons, machine parts, tools, and the like.
Many types of structural analyses are available in the ANSYS program, and are explained
below. The primary unknowns (nodal degree of freedom) calculated in a structural analysis are
displacements. Other quantities, such as strain, stresses, and reaction forces, are then derived
from the nodal displacements.
BUCKLING ANALYSIS -- to calculate the buckling load and determine the buckling mode
shape. Both linear (eigenvalue) buckling and nonlinear buckling analyses are possible.
MODAL ANALYSIS -- to calculate the natural frequency and mode shapes of a structure.
Different mode extraction methods are available.
SPECTRUM ANALYSIS -- an extension of the modal analysis, used to calculate stresses and
strains due to a response spectrum or a PSD input (random vibrations).
In addition to the above analysis types, several special-purpose features are available, such as
fracture mechanics, composites and fatigue.
The majority of ANSYS element types are structural elements, ranging from simple spars and
beams to more complex layered shells and large strain elements.
Perhaps the simplest form of analysis, a static analysis calculates the effects of steady loading
conditions on a structure. Inertia and damping effects, such as those due to time-varying loads,
are ignored. You can, however, include steady inertia loads, such as gravity and rotational
velocity. In addition, if time-varying loads can be approximated as static equivalent loads (such
as the static equivalent wind and seismic loads commonly defined in many building codes), their
effects can also be evaluated using a static analysis. The relative simplicity, economy, and broad
applicability of this method make it the most commonly used type of structural analysis.
Static analysis is used to determine the displacements, stresses, strains, and forces in structures
or components due to loads that do not include significant inertia and damping effects. Steady
loading and response conditions are assumed, i.e., the loads and the structure’s response are
assumed to vary slowly with respect to time. The kinds of loading that can be applied in a static
analysis include externally applied forces and pressures, steady-state inertial forces (such as
gravity or rotational velocity), imposed (non-zero) displacements, temperatures (for thermal
strain), and fluencies (for nuclear swelling).
A Static analysis can either be linear or nonlinear. All types of nonlinearities are allowed – large
deformations, plasticity, creep, stress stiffening, contact (gap) elements, hyper elastic elements,
etc.
ANSYS, Inc.
South point
275 Technology Drive Canonsburg, PA 15317
Phone: (412) 746-3304
FAX: (412) 512-9494
www.ansys.com