Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 14

CANTILEVER BEAM ANALYSIS (LRFD)

CB-1
DATA:

Span= 1200 mm Wu=


SIZE;
b= 250 mm
D= 300 mm 450.00 mm
LOADINGS:
ϒc= 24 kN/m3
NSCP2015 Table 205-1
FOR UNIFORMLY DISTRIBUTED LOAD
DEAD LOADS:
Ceramic or quarry tile (20mm) on
25mm mortar bed = 5.489 kN/m
T-beam Dead Load= 14.4 kN/m
Beam Self= 18 kN/m
WDL= 37.889 kN/m

LIVE LOADS
Pedestrian bridges and walkways
(Uniform Load, live loads)= 23.952 kN/m

FACTORED UNIFORM LOAD


Wu= 83.79 kN/m

Reduction factor, b= 0.85

DESIGN CRITERIA:
f'c= 20.76 Mpa
fy= 276 Mpa 100.55 kN
Main Bar= 20 mm Ø
Stirrup Bar= 10 mm Ø
d= 230 mm

Take a 1m Strip
60.33 kN.m

hmin= 119.142857142857 mm
say 120 mm

Mu= 60.3288 kN.m


ρmax= 0.027916728707564
Rnmax= 6.01779648584104 Mpa
Mumax= 71.6268226727229 kN.m Singly Reinforced

Rn= 5.06858223062382 Mpa


ρ= 0.0484587605224406
ρmin= 0.00412709628619367 Use C50

SINGLY REINFORCED BEAM


Tension Bars:
20 mm Ø , Grade 60
As= 2786.37873 mm2

Nb= 8.86929822 used 9.00 pcs

Compression Bars:
20 mm Ø , Grade 60

Nb= 1.8 used 2.00 pcs

SOLVE FOR SHEAR FORCES


Vu= 100.55 kN

Test for Shear Strength


Vn= 134.064 kN
Vc= 44.5379723 kN

Therefore: stirrup required

Vs= 89.5260277 kN

Vsmax= 172.912128 kN

Therefore: Section Adequate

CHECK MAX. STIRRUP SPACING


Vs= 89.5260277 kN
0.33(√f'c)bd= 86.4560638 kN

Smax=d/4
= 57.5
say Smax= 50 mm

DESIGNED FOR 2 LEGGED STIRRUPS


Stirrup and Spacing:
10 mm Ø , Grade 60
at x= 0
Vsx= 67.1445208

s=(Av fyt d )/Vsx > Smax


s= 148.507105 ok

Use 2-12 mm dia. Bar for stiffener bar


83.79 kN/m NOTE: REVIEW THE LOADING

###

V-diag.

M-diag.
ECCENTRICALLY LOADED COLUMN

TRY:

350.00 mm

500.00 mm

b= 350 mm
D= 500 mm
d= 430 mm
d'= 70 mm
Reinf. Bar:
6 20 mm Ø , Grade 60
f'c= 20.76 Mpa
fy= 276 Mpa

Required:
Pbn , eb , Mbn

Strain Diagram:
Ꞓs= 200000
Ꞓy= 0.00138

c= 294.5205479 mm
a= 250.3424658 mm

Ꞓs'= 0.00216
Comp. steel yields (fs'=fy)

ANALYZE FORCES:
As= 942.48 mm2
As'= 942.48 mm2
T= 260.12 kN
Cc= 1,546.14 kN
Cs'= 243.49 kN Consider Concrete Holes

ΣF=0
Pbn +T = Cc +Cs'
Pbn= 1,529.51 kN

ΣMT=0
XPbn - Cs'(d-d') - Cc(d-a/2)=0
X= 365.45 mm
Z= 180 mm
eb= 185.45 mm

Mbn= Pbn eb
Mbn= 283.653995 kN.m

CHECK COLUMN ADEQUACY


FOR CONCENTRATED LOAD (AS ASSUMED ADDITIONAL LOAD)
FOR Ultimate Load on Column
1. Assumed as Corridors above ground floor (LL) 10.19 kN
DL 45.12 kN
Pu= 70.448 kN
Mu= 60.33 kN.m
e= Mu/Pu
e= 856.3593 mm
Tension Control (tension steel yields)
Comp. steel may or may not yield,"comp.steelyields

Assume fs' = fy (comp. steel yields)


Cs' = As' (fy-0.85fc')
Cs'= 243.493478 kN
Cc=0.85fc'ab
Cc= 6.1761 a Eq.1
T=Asfy
T= 260.12448 kN

ΣF=0
Pn +T = Cc +Cs'
Pn = 6.1761 a -16.63 kN Eq.2

ΣMT=0
XPn - Cs'(d-d') - Cc(d-a/2)=0
but,
x=z+e
x= 1,221.81 mm
a - 1,583.63
2
a+ 34,966.28 =0
a1= 1,561.23 mm
a2= 22.40 mm
used, a= 1,561.23 mm

a=β1c
c= 1,836.74 mm

Ꞓs'= 0.003*((c-d')/c)
Ꞓs'= 0.00288567 ok
Ꞓs= 0.003*((d-c)/c)
Ꞓs= -0.0022977 revised

From Eq'n. 2
P
ECCENTRICALLY LOADED FOOTING
H: 3.9 m
Unitweight of conc.: 24 kN/m3
SBC: 71.82 kPa Clasification number 3
Weight Calculation:
Assume footing size: b= 1.4 m
w= 1.4 m
t= 0.3 m
Column: 16.38 kN
Footing: 14.112 kN
30.492 kN

Required Footing Size:


Base= 0.424561

You might also like