Download as pdf or txt
Download as pdf or txt
You are on page 1of 100

Electric Drawing List

SERIAL No. 16SX311020:001


No. FPRO Plus
Title MAIN
Drawing Name Drawing No.
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA01B-13
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA01B-26
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA01B-32
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA01B-41
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA01B-55
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA01B-62
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA03B-73
SEQUENCE DIAGRAM (COMMUNICATION LINE) 9CA-QA01B-80
SEQUENCE DIAGRAM (COMMUNICATION LINE) 9CA-QA01B-91
SEQUENCE DIAGRAM (COMMUNICATION LINE) 9CA-QA01B-A1
SEQUENCE DIAGRAM (COMMUNICATION LINE) 9CA-QA01B-B1
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA03B-C0
SEQUENCE DIAGRAM (MAIN CIRCUIT) 9CA-QA01B-D3
SEQUENCE DIAGRAM (UNIT DUCT(DC280V LINE)) 9CA-QA01B-E1
SEQUENCE DIAGRAM (UNIT DUCT(COM, LINE)) 9CA-QA01B-F1
SEQUENCE DIAGRAM (UNIT DUCT(PCB POWER)) 9CA-QA01B-G2
SEQUENCE DIAGRAM (SPAN CONTROLLER INPUT) 9CA-QA01B-H1
SEQUENCE DIAGRAM (SPAN CONTROLLER INPUT) 9CA-QA01B-J2
SEQUENCE DIAGRAM (SPAN CONTROLLER INPUT) 9CA-QA01B-K0
SEQUENCE DIAGRAM (SPAN CONTROLLER OUTPUT) 9CA-QA01B-L0
SEQUENCE DIAGRAM (SPAN CONTROLLER OUTPUT) 9CA-QA01B-M1
SEQUENCE DIAGRAM (SPAN CONTROLLER OUTPUT) 9CA-QA01B-N1
CONSTRUCTION DIAGRAM (MAIN CONTROL BOX) 9CA-QA01C-1C

1/1
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
HL210M
HL211M
HL212M

M007

INV001 L002
AP001

PU003
VOS3

SA001
Z003 AP008
PU014 PU015 PU016 AP006 SB005M AP005 AP007

Z002
QF001
QF005
PU011 PU012 PU013 AP002

M009 M008 QF004 SB017M


AP003 SB018M
SA019M
SA01AM
PU017 SB01BM
AP020 KM001 KM002

T001

PU002

KM004 QF002 QF00A


KM003 QF003
KM005 QF008
QF010 KM006 QF007
QF009 QF006

<BACK VIEW2> <BACK VIEW> <SIDE VIEW> <FRONT VIEW2> <FRONT VIEW1>

9CA
Electric Drawing List
SERIAL No. 16SX311020:001
No. FPRO Plus
Title UNIT
Drawing Name Drawing No.
SEQUENCE DIAGRAM (UNIT FRAME MAIN) 9C1-QF10B-10
SEQUENCE DIAGRAM (UNIT FRAME MAIN) 9C1-QF10B-20
SEQUENCE DIAGRAM (UNIT FRAME SLAVE) 9C1-QF10B-30
SEQUENCE DIAGRAM (UNIT FRAME SLAVE) 9C1-QF10B-40
SEQUENCE DIAGRAM (UNIT FRAME SLAVE) 9C1-QF10B-50
SEQUENCE DIAGRAM (UNIT FRAME TRV DRIVER) 9C1-QF10B-60
SEQUENCE DIAGRAM (UNIT FRAME HOT SPLICER) 9C1-QF10B-70

1/1
9C1
9C1
9C1
9C1
9C1
Electric Drawing List
SERIAL No. 16SX311030:001
No. 9CD
Title AD
Drawing Name Drawing No.
SEQUENCE DIAGRAM (POWER) 9CD-Q001B-10
SEQUENCE DIAGRAM (INPUT) 9CD-Q001B-20
SEQUENCE DIAGRAM (INPUT) 9CD-Q001B-30
SEQUENCE DIAGRAM (INPUT) 9CD-Q001B-40
SEQUENCE DIAGRAM (OUTPUT) 9CD-Q001B-52
SEQUENCE DIAGRAM (OUTPUT) 9CD-Q001B-63
SEQUENCE DIAGRAM (SIGNAL) 9CD-Q001B-70
CONSTRUCTION DIAGRAM (AD FRAME) 9CD-Q001C-14
SETTING DIAGRAM (TEX_SPC) 9CD-Q001C-20
SETTING DIAGRAM (TEX_SPC_AD_EXT) 9CD-Q001C-30
SETTING DIAGRAM (AD_I/F) 9CD-Q001C-41
SETTING DIAGRAM (TRAVELING MOTOR DRV) 9CD-Q001C-50
WIRING DIAGRAM (AD CIRCUIT) 9CD-Q001A-13

1/1
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
Electric Drawing List
SERIAL No. 16SX311040:001
No. 9CF
Title CBF(Tray to Tray)
Drawing Name Drawing No.
SEQUENCE DIAGRAM (POWER CIRCUIT) 9CF-QL01B-15
SEQUENCE DIAGRAM (POWER CIRCUIT) 9CF-QL01B-26
SEQUENCE DIAGRAM (MOTOR CIRCUIT) 9CF-QL01B-34
SEQUENCE DIAGRAM (CONTROL CIRCUIT) 9CF-QL01B-50
SEQUENCE DIAGRAM (I/O CIRCUIT) 9CF-QL01B-72
SEQUENCE DIAGRAM (I/O CIRCUIT OPERATION PANEL) 9CF-QL01B-81
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE2) 9CF-QL01B-93
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE3) 9CF-QL01B-A1
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE6) 9CF-QL01B-D3
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE7) 9CF-QL01B-E2
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE8) 9CF-QL01B-F4
SEQUENCE DIAGRAM (CAN COMMUNICATION) 9CF-QL01B-G4
CONSTRUCTION DIAGRAM (CBF CONTROL BOX) 9CF-QL01C-13
CONSTRUCTION DIAGRAM (OPERATION PANEL) 9CF-QL01C-20
CONSTRUCTION DIAGRAM (CBF FRAME 1K1C R-H) 9CF-QL01C-41
CONSTRUCTION DIAGRAM (INTERFACE C/V) 9CF-QL01C-70
CONSTRUCTION DIAGRAM (COP-ROBO,STRIPPER) 9CF-QL01C-82
CONSTRUCTION DIAGRAM (TEX SPC) 9CF-QL01C-B1
CONSTRUCTION DIAGRAM (R-I/O SLAVE) 9CF-QL01C-C2
CONSTRUCTION DIAGRAM (SLAVE I/O 5/5) 9CF-QL01C-D1
CONSTRUCTION DIAGRAM (CBF I/F PCB) 9CF-QL01C-E1
CONSTRUCTION DIAGRAM (STEPPER DRIVER) 9CF-QL01C-F2
WIRING DIAGRAM (MAIN-CBF-INTERFACE C/V) 9CF-QL01D-12
WIRING DIAGRAM (CONTROL BOX) 9CF-QL01A-13
WIRING DIAGRAM (OPERATION PANEL) 9CF-QL01A-20
WIRING DIAGRAM (AC MOTOR) 9CF-QL01A-40
WIRING DIAGRAM (STEPPING MOTOR) 9CF-QL01A-54
WIRING DIAGRAM (SLAVE2) 9CF-QL01A-62
WIRING DIAGRAM (SLAVE3) 9CF-QL01A-71
WIRING DIAGRAM (SLAVE6) 9CF-QL01A-A3

1/2
Drawing Name Drawing No.
WIRING DIAGRAM (SLAVE7) 9CF-QL01A-B1
WIRING DIAGRAM (SLAVE8) 9CF-QL01A-C2
DISPLAY DIAGRAM (TROUBLE DISPLAY SHEET) 9CF-QL01E-10
DISPLAY DIAGRAM (SPINNER SIGNAL SHEET) 9CF-QL01E-20

2/2
9CF
9CF
9CF
9CF
YA200C

9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
1

9CF
Codes, Symbols and Explanations of Major Electric Components
Name Code Symbol (IEC) Function
This is a breaker which protects a
circuit from damage resulting from
an overcurrent. The switch is opened
Circuit breaker QF (turned off) automatically when
overcurrent passes through the circuit.
The circuit breaker is a type of no-fuse
switch.
In principle there is no difference
between a circuit breaker and a circuit
protector.
Circuit protectors are used for
Circuit
protector
QF protection of "minimal capacity" control
circuits, heaters, motors, solenoid
valves, transformers, electronic
circuits, etc. (which cannot be
protected by breakers).

3 element 2 element

This is a protective device which


Motor breaker QF conforms to motor characteristics.
Protective equipment, switching equipment

Mainly used for protecting the


Glass tube components of a circuit from damage
fuse
FU when overcurrent runs through the
circuit.

Coil (3 element) (2 element) Switching devices which are a


combination of electromagnetic
contactors which open and close
Electromagnetic electric circuits based on the operation
KM
switching of an electromagnet and thermal relays
devices FR which interrupt electrical circuits based
on electrical overloads, etc.
Refer to thermal relay for thermal relay
contactors.

Coil a-contacts b-contacts


This is a device which has several sets
of breaker type switches for opening
Electromagnetic
contactor
KM and closing moving contacts. This is
used for a switch (ON/OFF) of motor
circuit, etc.

Thermal Thermal a-contacts b-contacts


(3 element) (2 element) *1 *2
A device consisting of a heater and a
thermal switch. It becomes hot when
Thermal relay FR overcurrent flows through the heater
circuit, thereby opening the contact.

This switch closes the moving contact


in response to thermal conditions when
Thermal switch
(Thermoswitch)
ST the ambient temperature exceeds a
specified point. (It is generally installed
to a motor.)

1 Doc No. A034


Electric Drawing Version 160301
Name Code Symbol (IEC) Function
Star delta
Device which raises or lowers
AC voltage using electromagnetic
Insulating
transformer
T induction. This is a type where both the
primary wiring and secondary wiring
are insulated.

Device which raises or lowers


AC voltage using electromagnetic
induction. This is a type where part
of the primary wiring and secondary
Auto wiring are shared. For this reason,
transformer
T there is no insulation between the
primary wiring and secondary wiring.
Further, because the coils are shared,
the device can be made small form
and lightweight.

Coil installed on the inverter circuit.


Reactor L This has effects on power factor
improvement and harmonic control.

Constant A power supply which stays constant


Power supply devices

voltage power PU without being affected by voltage


supply output load fluctuations.

Single phase 3 phase Items which are created to transform


AC (alternating current) to DC (direct
current).
Rectifier VC Composed of diodes and other
rectifiers.

Device which outputs electrical


energy by creating potential difference
Battery GB between electrodes through chemical
reactions, etc.

*3

Electrical circuits, electronic circuits,


Noise filter Z devices etc. for removing noise.

*4
Used to protect against surges caused
by lightning, electrostatic discharges,
Surge killer R switching, etc., and other transitional
excessive voltage.

Surge A circuit or device for absorbing surge


absorber
Z voltage.

2 Doc No. A034


Electric Drawing Version 160301
Name Code Symbol (IEC) Function

Device which controls motor RPM


Inverter INV by changing motor power supply
frequency.
Power supply devices

Under voltage Device which automatically trips the


trip device
UVT breaker when the voltage drops.

Momentary
power failure Device which detects momentary
detection
PFD outages.
device

Coil a-contacts b-contacts Used for making or breaking one


or more connections in electric
circuits. While there are switches
used for opening and closing circuits
manually, relays serve to make and
Relay KA break contacts by means of electrical
signals (voltages and currents).
Electromagnetic relays are a typical
example of relays. These relays use an
electromagnet for contact activation.

Coil a-contacts b-contacts


Control devices

Relay which operates the contact point


Timer relay after the set time is exceeded when the
(ON delay)
KT coil turns ON. Also operates instantly
when it turns OFF.

Coil a-contacts b-contacts


Relay which operates the contact point
Timer relay after the set time is exceeded when the
(OFF delay)
KT coil turns OFF. Also operates instantly
when it turns ON.

Since the back of a PCB is printed


with an electrically conductive pattern,
Printed circuit multiple electronic components
board (PCB)
AP (elements such as diodes, transistors,
etc.) are mounted and connected
without conventional wiring.

3 Doc No. A034


Electric Drawing Version 160301
Name Code Symbol (IEC) Function

Momentary type Alternate type


a-contacts b-contacts a-contacts b-contacts
In case of emergency during operation,
press this switch by hand to stop
the machine immediately. When the
Emergency
stop switch
SB machine has been stopped by means
of the emergency switch, the machine
cannot be restarted until the switch
knob is turned or pulled forward.

Holding down this switch opens or


*5 *6 closes the moving contact. Push button
switches fall into two types: some will
return to the open position when the
Push button operator's hand is removed from the
switch
SB switch (momentary type); some will
remain at the closed position even
when the operator's hand is removed.
To release a switch of the latter type, it
is necessary to press it once again.

Turn the selector switch knob for


making connections to a specific circuit
or for selecting a pattern of closed
contacts. Selector switches fall into
Selector
switch
SA two types: some will remain at the
set position even when the operator's
hand is removed; some will return to
Operation switches

the home position automatically when


the operator's hand is removed.

Moving the lever upward or downward


*7 *8 (or to the right or left) by hand changes
the ON/ OFF setting of the power as
Toggle switch well as the circuit. Two types of toggle
switches are available: toggle switches
SA whose lever can be set at a specific
Rocker switch position; and toggle switches whose
lever will return to the home position
automatically after it has been moved
to the other position.

This is a small-size switch which is


Microswitch SQ activated when external mechanical
force moves the moving contact.

This is a large-size switch which is


activated when external mechanical
force moves the moving contact.
Limit switch SQ The limit switch is designed to open,
close, or change the circuit when the
controlled system reaches the limit of
its operating range.
Consists of a glass tube filled with an
inert gas and contacts sealed inside
the tube. The reed switch has no
mechanically moving parts, operating
Reed switch SQ when the presence of objects
(magnetic substances) is detected
as the objects approach the switch.
It is defined as a small-size proximity
switch.

4 Doc No. A034


Electric Drawing Version 160301
Name Code Symbol (IEC) Function
Sensor which has no mechanical
moving parts, and can operate by
detecting if the object comes close to
Proximity the sensor without actually contacting
sensor
SQ it. There is a type which detects if
metal comes nearby and a type which
uses changes in capacitance for
detection of even non-metals.

Sensor which operates when it detects


Photoelectric
SQ an interruption of or receives projected
Sensors

sensor light.

*9
Sensor which converts and outputs
Pressure P changes in pressure of gases or liquids
sensor
SP as electrical signals via a pressure
element.

Thermocouple B A sensor for measuring heat.

Indication Display which shows machine


lamp
HL operation status, etc.

The signal tower consists of several


Indication devices

lamps in tiers, conveying information


including the operating status of
the machine. It is placed in a easy-
Signal tower HL to-see place (at the end or top of
the machine). This enables the
operators and personnel in charge of
maintenance to take necessary actions
immediately.
This is an internal lamp which lights
and rotates when the power is turned
on. It is mainly used for informing the
Rotating light HL operators and personnel in charge of
maintenance of the occurrence of a
machine trouble, etc.

5 Doc No. A034


Electric Drawing Version 160301
Name Code Symbol (IEC) Function
3 phase Single phase
*10 *11 A coil-wound steel core is magnetized
(attracts metal substances nearby)
Induction when an electric current flows through
motor
M M M the coil. The induction motor produces
3 1 linear motion using this principle.
(Electromagnetic induction motor)

M A motor which operates on direct


DC motor M current.

Stepping M A synchronous motor which


motor
M synchronizes with pulse power.
Power devices

A coil which is created to attract


magnetic substances is referred to
Solenoid YA as a solenoid (electromagnet). The
solenoid produces linear motion.

While the solenoid produces linear


Rotary
solenoid
YA motion, the rotary solenoid produces
rotary motion.

A valve that is opened and closed by


means of a solenoid (electromagnet).
The valve is opened when the coil is
energized by flowing current through
Solenoid valve YV it. When it is de-energized by stopping
the flow of current, the valve is pressed
against the valve seat by the force
of gravity, fluid pressure, or spring,
thereby closing the flow path.

Terminal block XT Small block for wiring connection


Wiring devices

Socket plug Plug Socket Device for connecting electrical wires


to other electrical wires or electrical
X
Connector devices. Made up of a plug with
CN protruding pins and a socket which
receives the pins.

6 Doc No. A034


Electric Drawing Version 160301
Name Code Symbol (IEC) Function
Fixed resistor Variable resistor
Every object offers, more or less,
opposition to the flow of electric
Resistor R current. A device which uses this
property to limit current flow is called a
resistor.

Standard condenser Electrolytic condenser


(non polar) (polar)
A device having two parallel metal
Condenser C plates, storing electrical energy
between them.

Electrical wires wound in a spiral coil.


Coil L Works to maintain a constant current.

NPN PNP

Semiconductor device which has a


Transistor V current amplification function.
Electronic circuit parts

Standard diode Zener diode

A semiconductor device designed to


Diode V limit the flow of current to only one
direction; from (+) to (-).

Light device composed of a complex


Light emitting semiconductor which emits light. LED
diode
V is small in size, sturdy and has a long
operational life.

A small switch mounted on a printed


circuit board. Set the individual sliding
DIP switch SA parts of the DIP switch to ON or OFF,
when necessary.

A small switch mounted on a printed


DIP rotary circuit board. Binary or BCD codes
switch
SA can be set through connection with
stamped numbers.

Jumper JP Terminal for short circuits.

7 Doc No. A034


Electric Drawing Version 160301
Name Code Symbol (IEC) Function

Earth PE Connects wireways, devices, etc. to the Earth for safety.


Earth, shields, etc.

Ground GND Standard potential in an electical circuit.

A shield which reduces permeation of electromagnetic


Shield --- fields.

A method of twisting electrical wires to reduce noise


Twisted pair --- effects.

Dashed line --- Indicates device links.


Line types

Alternating
Indicates boundaries when drawing a portion of boards,
long and short --- equipment, etc.
dashes

Alternating
single long
and double
--- Indicates specification divisions and options.

short dashes

IEC symbols are composed of the following content.


● Contact indicator direction ● Function symbols
The clockwise rotation direction when operated. The following functions are given to connecting
a-contacts and b-contacts are as follows. parts.
Connection function

Interruption function
a-contacts b-contacts
(Normally open contact) (Normally closed contact)
Spring restoration function *12

Residual function *13

Delay function

● Operational symbols
The following functions are given to operation
parts.
Push operation

Pull operation

Twist operation

8 Doc No. A034


Electric Drawing Version 160301
[ New and old symbol comparison table ]
Name Code New Old New Old
a-contacts b-contacts

Thermal relay FR *1 *2

Noise filter Z *3

Surge killer R *4

a-contacts b-contacts

Push button switch SB *5 *6

a-contacts b-contacts
Toggle switch
SA *7 *8
Rocker switch

SP P *9
Pressure sensor

3 phase Single phase

Induction motor M M *10 M *11


3 1

Spring restoration *12


function

Residual function *13

9 Doc No. A034


Electric Drawing Version 160301
Ana Elektrik Bileşenlerinin Kodları, Simgeleri ve Açıklamaları
İsim Kod Sembol (IEC) Fonksiyon
Bu, bir devreyi aşırı akımdan dolayı
oluşan hasarlardan koruyan bir
şalterdir. Düğme, aşırı akım devre
Otomat şalteri QF üzerinden geçtiği zaman otomatik
olarak açılır (yani söner). Devre şalteri
bir tip sigortasız düğme gibidir.

Prensipte bir otomat şalteri ile bir devre


koruyucusu arasında hiçbir fark yoktur.
Devre koruyucuları, (kesiciler
Devre tarafından korunamayan) "minimum
koruyucusu
QF kapasiteli" kontrol devrelerini, ısıtıcıları,
motorları, manyetik valfleri, trafoları,
elektronik devreleri, vs. korumak için
kullanılır.

3 eleman 2 eleman

Motor devre Bu motorun özelliklerine uyumlu


kesici
QF koruyucu cihazdır.
Koruyucu ekipman, geçiş ekipmanı

Esas olarak, bir devrenin bileşenlerini


devre üzerinden aşırı akım geçtiği
Cam tüp zaman ortaya çıkan hasarlardan
sigorta
FU korumak, özellikte güç devresi veya
yarı iletken entegreleri korumak için
kullanılır.

Bobin (3 eleman) (2 eleman) Geçiş cihazları, elektrik devrelerini


bir elektronik mıknatısın ve elektrik
devrelerini elektrik taşmalara vs.
dayalı olarak kesen termik rölelerinin
Elektromanyetik KM çalışmasına dayalı olarak açıp kapatan
geçiş cihazları FR elektromanyetik kontaktörlerin bir
kombinasyonudur
Termik röle kondaktör için termik
röle’ye bakın.

Normalde Normalde
Bobin
açık kontak kapalı kontak Hareketli kontakları açmak için
veya kapatmak için birçok şalter tipi
Elektromanyetik
kontaktör
KM düğmeler setine sahip bir cihazdır.
Bu cihaz, motor devresinin, v.s. bir
düğmesi (ON/OFF) olarak kullanılır.

Normalde Normalde
Termik Termik
açık kontak kapalı kontak
(3 eleman) (2 eleman)
*1 *2 Bir ısıtıcı ile bir termal düğmeden
oluşan bir cihazdır. Aşırı akım ısıtıcı
Termik röle FR devresi üzerinden geçtiği zaman sıcak
hale gelir ve böylece kontakları açar.

Bu siviç, ortam sıcaklığı belirlenmiş


olan bir noktayı geçtiği zaman termo
Termo siviç ST şartlara bir tepki olarak hareketli
kontağı açar. (Bu siviç genellikle bir
motora monte edilir.)

1 Doc No. A034


Electric Drawing Version 160301
İsim Kod Sembol (IEC) Fonksiyon

Yıldız Üçgen
Elektromanyetik endüksiyonu
kullanarak AC voltajını artıran veya
Yalıtımlı
transformatör
T düşüren cihaz. Bu, hem giriş bobin
sargısı ile hem de çıkış bobin sargısı
yalıtılmış olan bir tiptir.

Elektromanyetik endüksiyonu
kullanarak AC voltajını artıran veya
düşüren cihaz. Bu, giriş bobin
sargısı ile çıkış bobin sargısı ortak
Otomatik
transformatör
T kullanan bir tiptir. Bu nedenle, giriş
bobin sargısı ile çıkış bobin sargısı
arasında yalıtım yoktur. Ayrıca bobinler
paylaşıldığından, cihaz, küçük formda
ve hafif olabilir.

İnvertör devresine takılı bobin. Bunun


Reaktör L güç faktörünü geliştirme ve harmonik
kontrol üzerinde etkileri vardır.

Giriş voltaj ve voltaj çıkışındaki yük


Sabit voltajlı
PU dalgalanmalarından etkilenmeden sabit
Güç girişi cihazları

güç girişi kalan bir güç girişi

Tek faz 3 faz


AC’yi (alternatif akımı) DC’ye (doğru
akıma) dönüştürmek için oluşturulan
Doğrultmaç VC öğeler.
Diyotlardan ve diğer doğrultmaçlardan
oluşur.

Kimyasal reaksiyonlar vs. yoluyla


elektrotlar arasında potansiyel farklar
Akü GB oluşturarak elektrik enerjisi oluşturan
cihaz.

*3
Gürültüyü ortadan kaldırmak için
Gürültü filtresi Z elektrik devreleri, elektronik devreler,
cihazlar vs.

*4
Yıldırım, elektrostatik deşarj, geçiş,
Aşırı artış vs.den kaynaklanan aşırı artışlara ve
silici
R geçişle ilgili diğer aşırı voltajlara karşı
korumak için kullanılır.

Ani voltajın emilmesi için devre veya


Şok emici Z cihaz.

2 Doc No. A034


Electric Drawing Version 160301
İsim Kod Sembol (IEC) Fonksiyon

Motorun güç girişi frekansını


İnvertör INV değiştirerek, motorun devirini kontrol
eden cihaz.
Güç girişi cihazları

Düşük voltajlı
Voltaj düştüğünde kesiciyi otomatik
tetikleme UVT olarak tetikleyen cihaz.
cihazı

Anlık elektrik
Anlık elektrik kesintilerini algılayan
kesintisini PFD cihaz.
algılama cihazı

Normalde açık Normalde Elektrik devrelerindeki bir veya daha


Bobin kontak kapalı kontak
fazla bağlantıyı tesis etmek veya
kesmek için kullanılır. Devreleri elle
açmak veya kapatmak için kullanılan
düğmelere karış elektriksel sinyaller
(gerilimler ve akımlar) vasıtası ile
Röle KA kontak tesis etmek ve kontakları
kesmek için kullanılır. Elektromanyetik
röleler, rölelere tipik bir örnek olarak
gösterilebilir. Bu röleler kontak
aktivasyonu için bir elektromıknatıs
kullanır.

Normalde açık Normalde


Kontrol cihazları

Bobin kontak kapalı kontak Röleye sinyal geldiğinde ayarlanan


Zamanlayıcı süre aşıldıktan sonra kontakları
rölesi KT kapattıran zamanlayıcı röledir. Ayrıca
(ON gecikmesi) röle sinyali kesildiğinde kontakları
anında açırır.

Normalde açık Normalde


Bobin kontak kapalı kontak
Röle sinyal kesildiğinde ayarlanan
Zamanlayıcı
süre aşıldıktan sonra kontakları açtıran
rölesi KT zamanlayıcı röledir. Ayrıca röle sinyali
(OFF gecikmesi) geldiğinde kontakları anında kapanır.

Elektriksel olarak iletken bir model ile


baskılı olduğu için, çoklu elektronik
Baskılı devre bileşenler (diyotlar, transistörler, v.s.
kartı (PCB)
AP gibi elemanlar) alışılagelmiş sıradan
kablo tesisatı kullanılmaksızın monte
edilir ve bağlanır.

3 Doc No. A034


Electric Drawing Version 160301
İsim Kod Sembol (IEC) Fonksiyon

Anlık tip Kalıcı tip


Normalde Normalde Normalde Normalde
açık kontak kapalı kontak açık kontak kapalı kontak
İşletim esnasında acil durumla
karşılaşılması halinde, makineyi
hemen durdurmak için elinizle bu
Acil durum düğmeye basınız. Acil durum düğmesi
düğmesi
SB vasıtasıyla makine durdurulduğu
zaman, düğme butonu döndürülünceye
veya geri çekilinceye kadar makine
yeniden başlatılamaz.
*5 *6 Bu düğmenin basılı tutulmasıyla,
hareket kontağı açılır veya kapanır.
Basmalı tip düğme iki farklı tipte
bulunmaktadır: bazıları, elini
düğmenin üzerinden çektiği zaman
Basmalı tip
düğme
SB açık pozisyona geri döner (anlık tip);
bazıları da elini düğmenin üzerinden
çekse bile kapalı pozisyonda
kalır(kalıcı tip) ve eski konumuna
getirmek için, buna bir kez daha
basmak gereklidir.

Belirli bir devreye bağlantıları


gerçekleştirmek veya kapalı
kontaklardan bir örnek model
seçmek için seçici dönmeli düğmesini
Seçici
düğmesi
SA döndürünüz. Seçici düğmeleri iki tipe
ayrılmaktadır: bazıları elini çektiği zaman
Çalışma düğmeleri

bile ayar pozisyonunda kalır; bazıları


da elini çektiği zaman otomatik olarak
başlangıç konumuna geri döner.

*7 *8 Elinizle kolu yukarıya veya aşağıya


(veya sağa ya da sola) doğru hareket
ettirdiğinizde, gücün veya devrenin
ON-OFF siviç ON/OFF ayarını değiştirirsiniz. İki tip
ON-OFF siviç mevcut bulunmaktadır:
SA kolu/manivelası belirli bir pozisyona
Kulbütör ayarlanabilen ON-OFF siviçleri; ve
düğmesi kolu/manivelası herhangi bir konuma
getirildikten sonra otomatik olarak
başlangıç pozisyonuna geri gelen
ON-OFF siviçleri.

Bu siviç, harici mekanik güç


hareketli kontağı harekete
Mikro-siviç SQ geçirdiği zaman aktif olan
ufak boyutlu bir siviçtir.

Bu siviç, harici mekanik güç hareketli


kontağı harekete geçirdiği zaman aktif
olan büyük boyutlu bir siviçtir. Limit
Limit siviç SQ siviç, kontrollü sistem işletim skalası
dahilinde limit değerine ulaştığı zaman
devreyi açacak, kapatacak veya
değiştirecek şekilde tasarlanmıştır.
Hareketsiz bir gaz ile doldurulmuş
bir cam boru ve borunun içerisine
mühürlenmiş kontaklardan oluşur.
REED siviç, nesneler (manyetik
maddeler) sivice yaklaşmaktayken bu
REED siviç SQ nesnelerin varlığı tespit edildiğinde
harekete geçen mekanik olarak
hareketli hiçbir aksama sahip değildir.
Bu siviç, küçük-boyutlu yakınlaştırma
sivici olarak tanımlanır.

4 Doc No. A034


Electric Drawing Version 160301
İsim Kod Sembol (IEC) Fonksiyon
Mekanik hareketli parçası olmayan
ve nesnenin sensöre dokunmadan
yaklaşıp yaklaşmadığını algılayarak
Yaklaşma çalışabilen sensör. Metal maddelerin
SQ yaklaşıp yaklaşmadığını algılayan bir
sensörü
tiple, metal olmayan maddeleri bile
algılama kapasitesindeki değişikleri
kullanan bir tip vardır.

Fotosel Yansıtılan ışığı veya kesintisini


SQ
Sensörler

sensörü algıladığında çalışan bir sensördür.

*9

Basınç elemanı yardımıyla gaz veya


Basınç P
SP sıvıların basıncındaki değişiklikleri
sensörü elektrik sinyallerine dönüştüren sensör.

Isı ölçer B Isı ölçümü için sensor.

Belirtme Makinenin çalışma durumunu, vs.


lambası
HL gösteren lamba.

Kule lambası, katlar arasında yer alan


ve makinenin işletim durumu da dahil
Belirtme cihazları

bilgiler aktaran birçok lambadan


oluşmaktadır. Görülmesi kolay bir
Sinyal kulesi HL yere (makinenin ucunda veya en
üstünde) yerleştirilmiştir. Böylece bu
da, operatörlerin ve bakım işi ile görevli
personelin gerekli işlemleri anında
yapabilmesini sağlar.
Bu lamba, güç açık olduğu zaman
hem yanan hem de dönen dahili bir
lambadır. Makinenin ucunda veya
Döner lamba HL en üstünde yerleştirir ve bir makine
arızası v.s. olduğu zaman operatörleri
ve makine bakımı ile görevli personeli
bilgilendirmek için kullanılır.

5 Doc No. A034


Electric Drawing Version 160301
İsim Kod Sembol (IEC) Fonksiyon
3 faz *10 Tek faz *11 Bir elektrik akımı bobin üzerinden
geçtiği zaman, bobin-sarımlı bir çelik
merkez manyetize edilir (yakınındaki
İndüksiyon
motoru
M M M metal maddeleri çeker). İndüksiyon
3 1 motoru da bu prensibi kullanarak döner
bir hareket oluşturur. (Elektromanyetik
indüksiyon motoru).

DC (Doğru M
akım) Motor
M Doğru akımda çalışan motor

Darbe gücü ile senkronize çalışan,


Step motor M M senkron motor.
Güç cihazları

Manyetik maddeleri çekmek için


oluşturulan bir bobine mıknatıs
Solenoid YA (elektromıknatıs) denir. Mıknatıs,
doğrusal hareket sağlıyor.

Solenoid lineer bir hareket üretirken,


Döner
solenoid
YA döner solenoid ise döner bir hareket
üretir.

Bir solenoid (elektromıknatıs) vasıtası


ile açılan ve kapatılan bir valftır. Valf,
üzerinden akım geçmesi/akması
suretiyle bobin enerji dolduğu zaman
Solenoid valfı YV açılır. Akım akışının durmasından
dolayı enerjisi boşaldığı zaman
yerçekimi gücü ve akış basıncı veya
bir yay vasıtası ile valf, valf yatağına
doğru bastırılır ve akış yolunu kapatır.
Kablo bağlantısı cihazları

Klemens XT Kablo bağlantısı için küçük blok.

Soket fişi Fiş Soket Elektrik tellerini diğer elektrik tellerine


veya elektrikli cihazlara bağlama
X
Konnektör parçası.
CN Dışarıya taşan pimleri olan bir fişle
pimlerin girdiği bir yuvadan oluşur.

6 Doc No. A034


Electric Drawing Version 160301
İsim Kod Sembol (IEC) Fonksiyon
Sabit rezistör Değişken rezistör Her nesne/madde, ister az isterse
çok olsun, elektrik akımının akışına
ters yönde direnç gösterir. Akım akış
Direnç R oranını sınırlamak için bu özelliği
kullanan bir bileşen direnç olarak
adlandırılır.
Standart Elektrolitik
kondansatör kondansatör
(kutup değil) (kutup)
Aralarında elektrik enerjisini depolayan
Kondensatör C birbirine paralel iki metal levhaya sahip
bir bileşendir.

Spiral bobine sarılı elektrik telleri.


Bobin L Sabit bir akımı korumak için çalışır.

NPN PNP

Akım genleştirme işlevine sahip bir yarı


Transistör V iletken parçadır.
Elektronik devre parçaları

Standart diyot Zener diyot


Akımın akışını sadece (+) kutuptan
(-) kutba bir doğrultuda sınırlandırmak
Diyot V üzere tasarlanmış bir yarı iletken
bileşendir. Bu bileşen ayrıca kristal
doğrultmaç olarak adlandırılır.

Işık yayan özel bir yarı iletkenden


Işık yayan oluşan bir ışık parçası. Küçük
diyot
V boyuttadır, sağlamdır ve uzun bir
çalışma ömrüne sahiptir.

Baskılı bir devre kartı üzerine monte


edilmiş ufak bir siviçtir.
DIP düğmesi SA Gerektiği zaman, DIP siviçin birbirinden
bağımsız kaymalı bölümlerini ON veya
OFF konumuna getiriniz.

Basılı bir devre kartı üzerine takılı


DIP döner küçük düğme.
düğme
SA İkili kodlar veya BCD kodları, basılı
numaralarla bağlantıyla ayarlanabilir.

Köprü JP Kısa devre ucu.

7 Doc No. A034


Electric Drawing Version 160301
İsim Kod Sembol (IEC) Fonksiyon

Tel yollarını, cihazları, vs. güvenlik amacıyla toprağa


Topraklama PE bağlar.
Topraklama, İzole, vs.

Temel GND Bir elektrik devresindeki voltaj temeli(0V).

İzole --- Elektromanyetik alanlara girişi azaltan bir kalkan.

Parazit etkilerini azaltmak için elektrik tellerini bükme


Bükümlü çift --- yöntemi.

Kesikli çizgi --- Cihazın bağlantılarını belirtir.


Satır tipleri

Değişmeli
Baskılı devre kartların, ekipmanın vs. bir kısmını çizerken
uzun ve kısa --- sınırları belirtir.
çizgiler

Değişmeli tek
uzun ve çift --- Özellik bölüm ve seçeneklerini belirtir.
kısa çizgiler

IEC simgeleri aşağıdaki içerikten oluşur.


● Kontak bağlantı gösterge yönü ● İşlev simgeleri
Çalışırken saat istikametinde döndürme yönü. Bağlantı parçalarına aşağıdaki işlevler verilir.
Normalde açık kontakt bağlantılarıyla normalde
kapalı kontak bağlantıları aşağıdaki şekildedir. Bağlantı işlevi

Kesinti işlevi
Normalde açık Normalde kapalı
kontak bağlantıları kontak bağlantılar
Yayı geri yükleme işlevi *12

Kalıcı işlevi *13

Gecikme işlevi

● Çalışma simgeleri
İşlem parçalarına aşağıdaki işlevler verilir.

Basma işlemi

Çekme işlemi

Çevrme işlemi

8 Doc No. A034


Electric Drawing Version 160301
[Yeni ve eski sembol karşılaştırma tablosu]
İsim Kod Eski Old Yeni Eski
Normalde açık Normalde kapalı
kontak kontak

Termik röle FR *1 *2

Gürültü filtresi Z *3

Aşırı artış silici R *4

Normalde açık Normalde kapalı


kontak kontak

Basmalı tip düğme SB *5 *6

Normalde açık Normalde kapalı


kontak kontak
ON-OFF siviç
SA *7 *8
Kulbütör düğmesi

P
Basınç sensörü SP *9

3 faz Tek faz

İndüksiyon motoru M 3
M *10 M *11
1

Yayı geri yükleme işlevi *12

Kalıcı işlevi *13

9 Doc No. A034


Electric Drawing Version 160301