Professional Documents
Culture Documents
Electric Drawings
Electric Drawings
1/1
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
9CA
HL210M
HL211M
HL212M
M007
INV001 L002
AP001
PU003
VOS3
SA001
Z003 AP008
PU014 PU015 PU016 AP006 SB005M AP005 AP007
Z002
QF001
QF005
PU011 PU012 PU013 AP002
T001
PU002
<BACK VIEW2> <BACK VIEW> <SIDE VIEW> <FRONT VIEW2> <FRONT VIEW1>
9CA
Electric Drawing List
SERIAL No. 16SX311020:001
No. FPRO Plus
Title UNIT
Drawing Name Drawing No.
SEQUENCE DIAGRAM (UNIT FRAME MAIN) 9C1-QF10B-10
SEQUENCE DIAGRAM (UNIT FRAME MAIN) 9C1-QF10B-20
SEQUENCE DIAGRAM (UNIT FRAME SLAVE) 9C1-QF10B-30
SEQUENCE DIAGRAM (UNIT FRAME SLAVE) 9C1-QF10B-40
SEQUENCE DIAGRAM (UNIT FRAME SLAVE) 9C1-QF10B-50
SEQUENCE DIAGRAM (UNIT FRAME TRV DRIVER) 9C1-QF10B-60
SEQUENCE DIAGRAM (UNIT FRAME HOT SPLICER) 9C1-QF10B-70
1/1
9C1
9C1
9C1
9C1
9C1
Electric Drawing List
SERIAL No. 16SX311030:001
No. 9CD
Title AD
Drawing Name Drawing No.
SEQUENCE DIAGRAM (POWER) 9CD-Q001B-10
SEQUENCE DIAGRAM (INPUT) 9CD-Q001B-20
SEQUENCE DIAGRAM (INPUT) 9CD-Q001B-30
SEQUENCE DIAGRAM (INPUT) 9CD-Q001B-40
SEQUENCE DIAGRAM (OUTPUT) 9CD-Q001B-52
SEQUENCE DIAGRAM (OUTPUT) 9CD-Q001B-63
SEQUENCE DIAGRAM (SIGNAL) 9CD-Q001B-70
CONSTRUCTION DIAGRAM (AD FRAME) 9CD-Q001C-14
SETTING DIAGRAM (TEX_SPC) 9CD-Q001C-20
SETTING DIAGRAM (TEX_SPC_AD_EXT) 9CD-Q001C-30
SETTING DIAGRAM (AD_I/F) 9CD-Q001C-41
SETTING DIAGRAM (TRAVELING MOTOR DRV) 9CD-Q001C-50
WIRING DIAGRAM (AD CIRCUIT) 9CD-Q001A-13
1/1
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
9CD
Electric Drawing List
SERIAL No. 16SX311040:001
No. 9CF
Title CBF(Tray to Tray)
Drawing Name Drawing No.
SEQUENCE DIAGRAM (POWER CIRCUIT) 9CF-QL01B-15
SEQUENCE DIAGRAM (POWER CIRCUIT) 9CF-QL01B-26
SEQUENCE DIAGRAM (MOTOR CIRCUIT) 9CF-QL01B-34
SEQUENCE DIAGRAM (CONTROL CIRCUIT) 9CF-QL01B-50
SEQUENCE DIAGRAM (I/O CIRCUIT) 9CF-QL01B-72
SEQUENCE DIAGRAM (I/O CIRCUIT OPERATION PANEL) 9CF-QL01B-81
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE2) 9CF-QL01B-93
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE3) 9CF-QL01B-A1
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE6) 9CF-QL01B-D3
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE7) 9CF-QL01B-E2
SEQUENCE DIAGRAM (I/O CIRCUIT SLAVE8) 9CF-QL01B-F4
SEQUENCE DIAGRAM (CAN COMMUNICATION) 9CF-QL01B-G4
CONSTRUCTION DIAGRAM (CBF CONTROL BOX) 9CF-QL01C-13
CONSTRUCTION DIAGRAM (OPERATION PANEL) 9CF-QL01C-20
CONSTRUCTION DIAGRAM (CBF FRAME 1K1C R-H) 9CF-QL01C-41
CONSTRUCTION DIAGRAM (INTERFACE C/V) 9CF-QL01C-70
CONSTRUCTION DIAGRAM (COP-ROBO,STRIPPER) 9CF-QL01C-82
CONSTRUCTION DIAGRAM (TEX SPC) 9CF-QL01C-B1
CONSTRUCTION DIAGRAM (R-I/O SLAVE) 9CF-QL01C-C2
CONSTRUCTION DIAGRAM (SLAVE I/O 5/5) 9CF-QL01C-D1
CONSTRUCTION DIAGRAM (CBF I/F PCB) 9CF-QL01C-E1
CONSTRUCTION DIAGRAM (STEPPER DRIVER) 9CF-QL01C-F2
WIRING DIAGRAM (MAIN-CBF-INTERFACE C/V) 9CF-QL01D-12
WIRING DIAGRAM (CONTROL BOX) 9CF-QL01A-13
WIRING DIAGRAM (OPERATION PANEL) 9CF-QL01A-20
WIRING DIAGRAM (AC MOTOR) 9CF-QL01A-40
WIRING DIAGRAM (STEPPING MOTOR) 9CF-QL01A-54
WIRING DIAGRAM (SLAVE2) 9CF-QL01A-62
WIRING DIAGRAM (SLAVE3) 9CF-QL01A-71
WIRING DIAGRAM (SLAVE6) 9CF-QL01A-A3
1/2
Drawing Name Drawing No.
WIRING DIAGRAM (SLAVE7) 9CF-QL01A-B1
WIRING DIAGRAM (SLAVE8) 9CF-QL01A-C2
DISPLAY DIAGRAM (TROUBLE DISPLAY SHEET) 9CF-QL01E-10
DISPLAY DIAGRAM (SPINNER SIGNAL SHEET) 9CF-QL01E-20
2/2
9CF
9CF
9CF
9CF
YA200C
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
9CF
1
9CF
Codes, Symbols and Explanations of Major Electric Components
Name Code Symbol (IEC) Function
This is a breaker which protects a
circuit from damage resulting from
an overcurrent. The switch is opened
Circuit breaker QF (turned off) automatically when
overcurrent passes through the circuit.
The circuit breaker is a type of no-fuse
switch.
In principle there is no difference
between a circuit breaker and a circuit
protector.
Circuit protectors are used for
Circuit
protector
QF protection of "minimal capacity" control
circuits, heaters, motors, solenoid
valves, transformers, electronic
circuits, etc. (which cannot be
protected by breakers).
3 element 2 element
*3
*4
Used to protect against surges caused
by lightning, electrostatic discharges,
Surge killer R switching, etc., and other transitional
excessive voltage.
Momentary
power failure Device which detects momentary
detection
PFD outages.
device
sensor light.
*9
Sensor which converts and outputs
Pressure P changes in pressure of gases or liquids
sensor
SP as electrical signals via a pressure
element.
NPN PNP
Alternating
Indicates boundaries when drawing a portion of boards,
long and short --- equipment, etc.
dashes
Alternating
single long
and double
--- Indicates specification divisions and options.
short dashes
Interruption function
a-contacts b-contacts
(Normally open contact) (Normally closed contact)
Spring restoration function *12
Delay function
● Operational symbols
The following functions are given to operation
parts.
Push operation
Pull operation
Twist operation
Thermal relay FR *1 *2
Noise filter Z *3
Surge killer R *4
a-contacts b-contacts
a-contacts b-contacts
Toggle switch
SA *7 *8
Rocker switch
SP P *9
Pressure sensor
3 eleman 2 eleman
Normalde Normalde
Bobin
açık kontak kapalı kontak Hareketli kontakları açmak için
veya kapatmak için birçok şalter tipi
Elektromanyetik
kontaktör
KM düğmeler setine sahip bir cihazdır.
Bu cihaz, motor devresinin, v.s. bir
düğmesi (ON/OFF) olarak kullanılır.
Normalde Normalde
Termik Termik
açık kontak kapalı kontak
(3 eleman) (2 eleman)
*1 *2 Bir ısıtıcı ile bir termal düğmeden
oluşan bir cihazdır. Aşırı akım ısıtıcı
Termik röle FR devresi üzerinden geçtiği zaman sıcak
hale gelir ve böylece kontakları açar.
Yıldız Üçgen
Elektromanyetik endüksiyonu
kullanarak AC voltajını artıran veya
Yalıtımlı
transformatör
T düşüren cihaz. Bu, hem giriş bobin
sargısı ile hem de çıkış bobin sargısı
yalıtılmış olan bir tiptir.
Elektromanyetik endüksiyonu
kullanarak AC voltajını artıran veya
düşüren cihaz. Bu, giriş bobin
sargısı ile çıkış bobin sargısı ortak
Otomatik
transformatör
T kullanan bir tiptir. Bu nedenle, giriş
bobin sargısı ile çıkış bobin sargısı
arasında yalıtım yoktur. Ayrıca bobinler
paylaşıldığından, cihaz, küçük formda
ve hafif olabilir.
*3
Gürültüyü ortadan kaldırmak için
Gürültü filtresi Z elektrik devreleri, elektronik devreler,
cihazlar vs.
*4
Yıldırım, elektrostatik deşarj, geçiş,
Aşırı artış vs.den kaynaklanan aşırı artışlara ve
silici
R geçişle ilgili diğer aşırı voltajlara karşı
korumak için kullanılır.
Düşük voltajlı
Voltaj düştüğünde kesiciyi otomatik
tetikleme UVT olarak tetikleyen cihaz.
cihazı
Anlık elektrik
Anlık elektrik kesintilerini algılayan
kesintisini PFD cihaz.
algılama cihazı
*9
DC (Doğru M
akım) Motor
M Doğru akımda çalışan motor
NPN PNP
Değişmeli
Baskılı devre kartların, ekipmanın vs. bir kısmını çizerken
uzun ve kısa --- sınırları belirtir.
çizgiler
Değişmeli tek
uzun ve çift --- Özellik bölüm ve seçeneklerini belirtir.
kısa çizgiler
Kesinti işlevi
Normalde açık Normalde kapalı
kontak bağlantıları kontak bağlantılar
Yayı geri yükleme işlevi *12
Gecikme işlevi
● Çalışma simgeleri
İşlem parçalarına aşağıdaki işlevler verilir.
Basma işlemi
Çekme işlemi
Çevrme işlemi
Termik röle FR *1 *2
Gürültü filtresi Z *3
P
Basınç sensörü SP *9
İndüksiyon motoru M 3
M *10 M *11
1