Sheet (6)
What is the reason for dividing the ground tank Cover the contact time for Reducing construction Avoid dead zones in
5 All of the above
into baffled walls disinfection costs for the roof the tank
No. Question Text A B C D
The fire demand of a city is 8000 m3 of water. If
the average drinking water discharge of this city is
6 180 185 190 195
1.5 m3/s, what is the water consumption of
residents in this city, L/c/d
The fire demand of a city is 8440 m3 of water. If
the average drinking water discharge of this city is
7 180 185 175 170
1.5 m3/s, what is the water consumption of
residents in this city, L/c/d
The fire demand of a city is 12000 m3 of water. If
the average drinking water discharge of this city is
8 216 212 208 204
2.5 m3/s, what is the water consumption of
residents in this city, L/c/d
The fire demand of a city is 8200 m3 of water. If
the average drinking water discharge of this city is
9 180 185 190 175
1.5 m3/s, what is the water consumption of
residents in this city, L/c/d
The fire demand of a city is 8650 m3 of water. If
the average drinking water discharge of this city is
10 180 175 170 160
1.5 m3/s, what is the water consumption of
residents in this city, L/c/d
The fire demand of a city is 8650 m3 of water. If
the average drinking water discharge of this city is
11 180 185 190 195
1.62 m3/s, what is the water consumption of
residents in this city, L/c/d
In a water treatment plant, the volume of ground 2 tanks 20 m length & 3 tanks 20 m length &
4 tanks 15 m length & 15 m 1 tank 30 m length & 30 m
12 tanks = 2200 m3. What are the best dimensions 20 m width & 3.0 m 15 m width & 2.5 m
width & 2.5 m depth width & 2.5 m depth
for these ground tanks depth depth
No. Question Text A B C D
In a water treatment plant, the volume of ground 2 tanks 35 m length & 4 tanks 35 m length &
3 tanks 30 m length & 30 m 1 tank 50 m length & 50 m
13 tanks = 10000 m3. What are the best dimensions 35 m width & 4.5 m 30 m width & 2.5 m
width & 4 m depth width & 4 m depth
for these ground tanks depth depth
In a water treatment plant, the volume of ground 2 tanks 45 m length & 4 tanks 35 m length &
6 tanks 25 m length & 20 m 1 tank 50 m length & 50 m
14 tanks = 16000 m3. What are the best dimensions 45 m width & 4.0 m 35 m width & 3.5 m
width & 5.5 m depth width & 6.5 m depth
for these ground tanks depth depth
In a water treatment plant, the volume of ground 2 tanks 45 m length & 4 tanks 40 m length &
6 tank 28 m length & 28 m 8 tanks 25 m length & 25 m
15 tanks = 30000 m3. What are the best dimensions 45 m width & 6.5 m 40 m width & 4.8 m
width & 6.5 m depth width & 6.5 m depth
for these ground tanks depth depth
In a water treatment plant, the volume of ground 4 tank 35 m length & 4 tanks 32 m length &
2 tanks 40 m length & 40 m 1 tank 65 m length & 60 m
16 tanks = 26000 m3. What are the best dimensions 30 m width & 6.5 m 32 m width & 6.5 m
width & 6.5 m depth width & 6.5 m depth
for these ground tanks depth depth
Ground tanks have the following data:
The volume for disinfection = 100 m3
The volume for emergency = 1600 m3
The volume for fire fighting (Vf) = 800 m3
17 4200 3300 2500 2340
The volume for difference between max
consumption daily and monthly=1700 m3
What is the total volume (m3) of these ground
tanks
Ground tanks have the following data:
The volume for disinfection = 300 m3
The volume for emergency = 4800 m3
The volume for fire fighting (Vf) = 1500 m3
18 6500 6200 11600 9800
The volume for difference between max
consumption daily and monthly=5000 m3
What is the total volume (m3) of these ground
tanks
No. Question Text A B C D
Ground tanks have the following data:
The volume for disinfection = 200 m3
The volume for emergency = 3200 m3
The volume for fire fighting (Vf) = 1000 m3
19 4000 4200 7400 6200
The volume for difference between max
consumption daily and monthly=3000 m3
What is the total volume (m3) of these ground
tanks
Ground tanks have the following data:
The volume for disinfection = 250 m3
The volume for emergency = 4000 m3
The volume for fire fighting (Vf) = 1000 m3
20 5200 9450 5000 8200
The volume for difference between max
consumption daily and monthly=4200 m3
What is the total volume (m3) of these ground
tanks
Ground tanks have the following data:
The volume for disinfection = 500 m3
The volume for emergency = 8000 m3
The volume for fire fighting (Vf) = 3000 m3
21 14500 18000 11000 10400
The volume for difference between max
consumption daily and monthly=6500 m3
What is the total volume (m3) of these ground
tanks