GLUCOSE MONITORING

FOR NEWBORNS ON IV FLUIDS


While on
IV FLUIDS Check
Blood
2 times
When Glucose
12 h 12 h STOPPING 20min every every every 12 h Level
a day FOR 12 HOURS
or 2-4 h 2-4 h 2-4 h or till
glucose is
CHECK ADJUSTING CHECK NORMAL
BLOOD IV fluids BLOOD 3 TIMES
GLUCOSE GLUCOSE IN A ROW
LEVEL LEVEL


Check blood glucose level prior to feeding

 RECORD
 all blood glucose levels & changes to IV fluids
BLOOD GLUCOSE LEVEL GOAL IN THE PATIENT CHART

IF Blood Glucose
First 48 hours of life Level is:

Check till GLUCOSE is NORMAL <45mg/dL


< ≥45mg/dL 3 TIMES IN A ROW  <2.5mmol/L
TREAT
After 48 hours of life for
Check till GLUCOSE is NORMAL HYPOGLYCAEMIA
<60mg/dL
> ≥60mg/dL 3 TIMES IN A ROW  <3.3 mmol/L

©MSF-OCB-September 2021-Neonatal Care: Clinical & Therapeutic Guidelines - Graphic Design: A.Filot