Professional Documents
Culture Documents
Revision - Piet 2
Revision - Piet 2
1. Insertion loss
2. Continuity, fiber or cable tracing, duplex connector polarity
3. Source or receiver power
4. Connector faults (scratches, polish, dirt)
5. Fault location, splice loss, length
6. Continuity, fiber tracing, fault location close to end of a cable
•In the following drawing of an insertion loss test using a light source
and power meter, identify the components:
Cable to test D
Connector mating adapter C
Launch cable B
Light source A
Power meter F
Receive cable E
•In the drawing below, match the letters to the insertion loss
power measurement at that point in the diagram.
Reference point for OFSTP-14, Method B
Loss of installed cable plant
•Match the terms below to the letters on the OTDR trace
shown.
Connector, showing loss and back reflection E
Distance scale B
End of the fiber F
Inital pulse and dead zone C
Loss scale A
Splice loss D
•Select the proper units of measure for each fiber specification.
A. dB
B. dBm
C. μm or microns
D. mm or inches
E. nm or nanometers
F. MHz or GHz
G. Feet or meters
Fiber size C
Wavelength E
Bandwidth F
Loss A
Absolute power B
Cable jacket outside diameter D
Cable length G