* STAAD.Pro CONNECT Edition *
* Version 22.00.00.15 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= APR 27, 2024 *
* Time= 9: 3:11 *
* *
* Licensed to: only @ ::LAVTeam:: (R) *
****************************************************

1. STAAD SPACE
INPUT FILE: D:\Others\Gerbon\Bahay Toro QC\STAAD\Two Storey Residential House (Bahay Toro QC).STD
2. START JOB INFORMATION
3. JOB NAME TWO STOREY RESIDENTIAL HOUSE (BAHAY TORO QC)
4. JOB CLIENT SPS.MR ROLANDO B.LICHAUCO & MRS.MARIA TERESA LARA LICHAUCO
5. JOB REV 0
6. ENGINEER NAME JEE
7. CHECKER NAME JEE
8. APPROVED NAME JEE
9. ENGINEER DATE 4/26/2024
10. CHECKER DATE 4/26/2024
11. APPROVED DATE 4/26/2024
12. END JOB INFORMATION
13. INPUT WIDTH 79
14. UNIT METER KN
15. JOINT COORDINATES
16. 1 0 0 0
17. 20 0 3.00001 0
18. 21 3.00001 0 0
19. 22 3.00001 3.00001 0
20. 23 6.00001 0 0
21. 24 6.00001 3.00001 0
22. 25 0 0 2
23. 26 0 3.00001 2
24. 27 3.00001 0 2
25. 28 3.00001 3.00001 2
26. 31 0 0 4.60001
27. 32 0 3.00001 4.60001
28. 33 3.00001 0 4.60001
29. 34 3.00001 3.00001 4.60001
30. 35 6.00001 0 4.60001
31. 36 6.00001 3.00001 4.60001
32. 37 6.00001 0 3.20001
33. 38 6.00001 3.00001 3.20001
34. 39 3.00001 3.00001 3.20001
35. 40 4.50001 3.00001 4.60001
36. 41 4.50001 3.00001 3.20001
37. 42 0 6.00001 0
38. 43 3.00001 6.00001 0

D:\Others\Gerbon\Bahay Toro QC\STAAD\Two Storey Residential House (Bahay Toro QC).anl Page 1 of 7
Saturday, 27 April 2024 9:06 am

STAAD SPACE -- PAGE NO. 2

39. 44 6.00001 6.00001 0


40. 45 0 6.00001 2
41. 46 3.00001 6.00001 2
42. 47 0 6.00001 4.60001
43. 48 3.00001 6.00001 4.60001
44. 49 6.00001 6.00001 3.20001
45. 50 3.00001 6.00001 3.20001
46. MEMBER INCIDENCES
47. 2 1 20
48. 4 20 22
49. 5 21 22
50. 7 22 24
51. 8 23 24
52. 10 20 26
53. 12 22 28
54. 14 24 38
55. 15 25 26
56. 16 26 28
57. 17 27 28
58. 21 26 32
59. 23 28 39
60. 26 31 32
61. 27 32 34
62. 28 33 34
63. 29 34 40
64. 30 35 36
65. 31 38 36
66. 32 37 38
67. 33 39 34
68. 34 39 41
69. 35 40 36
70. 36 41 38
71. 37 41 40
72. 38 20 42
73. 39 22 43
74. 40 24 44
75. 41 26 45
76. 42 28 46
77. 43 32 47
78. 44 34 48
79. 45 38 49
80. 48 42 43
81. 49 43 44
82. 50 42 45
83. 51 43 46
84. 52 44 49
85. 53 45 46
86. 54 45 47
87. 55 46 50
88. 56 47 48
89. 57 50 48
90. 58 50 49
91. DEFINE MATERIAL START
92. ISOTROPIC CONCRETE
93. E 2.17184E+07
94. POISSON 0.17

D:\Others\Gerbon\Bahay Toro QC\STAAD\Two Storey Residential House (Bahay Toro QC).anl Page 2 of 7
Saturday, 27 April 2024 9:06 am

STAAD SPACE -- PAGE NO. 3

95. DENSITY 23.5615


96. ALPHA 5.5E-06
97. DAMP 0.05
98. TYPE CONCRETE
99. STRENGTH FCU 27578.9
100. END DEFINE MATERIAL
101. MEMBER PROPERTY AMERICAN
102. 2 5 8 15 17 26 28 30 32 38 TO 45 PRIS YD 0.4 ZD 0.2
103. MEMBER PROPERTY AMERICAN
104. 48 TO 58 PRIS YD 0.3 ZD 0.2
105. MEMBER PROPERTY AMERICAN
106. 4 7 10 12 14 16 21 23 27 29 31 33 TO 37 PRIS YD 0.35 ZD 0.25
107. CONSTANTS
108. MATERIAL CONCRETE MEMB 2 4 5 7 8 10 12 14 TO 17 21 23 26 TO 45 48 TO 58
109. SUPPORTS
110. 1 21 23 25 27 31 33 35 37 FIXED
111. DEFINE REFERENCE LOADS
112. LOAD R1 LOADTYPE MASS TITLE DL1
113. SELFWEIGHT Y -1 LIST 2 4 5 7 8 10 12 14 TO 17 21 23 26 TO 45 48 TO 58
114. LOAD R2 LOADTYPE MASS TITLE DL2
115. END DEFINE REFERENCE LOADS

*** NOTE: MASS MODEL FORMED WILL BE USED IN SEISMIC/RESPONSE/TIME HISTORY LOADING, IF ANY.
IF MASS MODEL IS SEPARATELY PROVIDED IN INDIVIDUAL LOADING, THE GENERATED MASS
WILL BE REPLACED BY THE MASS PROVIDED IN INDIVIDUAL LOADING.

116. CHECK SOFT STORY ASCE7

**WARNING: RIGID DIAPHRAGMS ARE NOT DEFINED.


THERE WILL BE NO SOFT STORY CHECKING.
117. DEFINE UBC LOAD
118. ZONE 0.04 I 1 RWX 8.5 RWZ 8.5 STYP 4 CT 0.0731 NA 1.2 NV 1.2
119. DEFINE WIND LOAD

*** NOTE: If any floor diaphragm is present in the model Wind Load definition
should be defined after Floor Diaphragm definition. Otherwise wind
load generation may be unsuccessful during analysis.

120. TYPE 1 WIND 1


121. <! STAAD PRO GENERATED DATA DO NOT MODIFY !!!
122. ASCE-7-2010:PARAMS 150.000 KMPH 0 1 1 0 0.000 FT 0.000 FT 0.000 FT 1 1 -
123. 40.000 FT 30.000 FT 25.000 FT 2.000 0.010 0 0 0 0 0 0.761 1.000 1.000 0.850 -
124. 0 0 0 0 0.866 0.800 -0.550
125. !> END GENERATED DATA BLOCK
126. INT 0.738935 0.738935 0.751569 0.763215 0.774041 0.784173 0.793709 0.802726 -
127. 0.811288 0.819446 0.827244 0.834716 0.841895 0.848805 0.855471 HEIG 0 -
128. 4.57201 5.15816 5.74432 6.33047 6.91663 7.50278 8.08894 8.67509 9.26125 -
129. 9.8474 10.4336 11.0197 11.6059 12.192
130. LOAD 1 LOADTYPE NONE TITLE EX
131. UBC LOAD X 1 DEC 1 ACC 0.05
132. LOAD 2 LOADTYPE NONE TITLE EZ
133. UBC LOAD Z 1 DEC 1 ACC 0.05

D:\Others\Gerbon\Bahay Toro QC\STAAD\Two Storey Residential House (Bahay Toro QC).anl Page 3 of 7
Saturday, 27 April 2024 9:06 am

STAAD SPACE -- PAGE NO. 4

134. LOAD 3 LOADTYPE DEAD TITLE DL1


135. REFERENCE LOAD
136. R1 1.0
137. LOAD 4 LOADTYPE DEAD TITLE DL2
138. REFERENCE LOAD
139. R2 1.0
140. LOAD 5 LOADTYPE LIVE TITLE LL1
141. FLOOR LOAD
142. YRANGE 0 4.5 FLOAD -1.9 GY
**NOTE** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.

143. LOAD 6 LOADTYPE LIVE TITLE LL2


144. FLOOR LOAD
145. YRANGE 4 7 FLOAD -0.1 GY
146. LOAD 7 LOADTYPE ROOF LIVE TITLE LLR
147. FLOOR LOAD
148. YRANGE 4 7 FLOAD -0.5 GY
149. LOAD 8 LOADTYPE WIND TITLE WX
150. WIND LOAD X 1 TYPE 1
151. WIND LOAD Z 1 TYPE 1
152. WIND LOAD -X 1 TYPE 1
153. WIND LOAD -Z 1 TYPE 1
154. LOAD COMB 101 1.4DL
155. 3 1.4 4 1.4
156. LOAD COMB 102 1.2DL + 1.6LL + 0.5LLR
157. 3 1.2 4 1.2 5 1.6 6 1.6 7 0.5
158. LOAD COMB 103 1.2DL + 1.6LLR + F1LL
159. 3 1.2 4 1.2 5 0.5 6 1.0 7 1.6

D:\Others\Gerbon\Bahay Toro QC\STAAD\Two Storey Residential House (Bahay Toro QC).anl Page 4 of 7
Saturday, 27 April 2024 9:06 am

STAAD SPACE -- PAGE NO. 5

160. LOAD COMB 104 1.42(DL1 + DL2) + 0.5LL1 + 0.5LLR + 1.0LL2 + 1.0EX + 0.3EZ
161. 3 1.42 4 1.42 5 0.5 7 0.5 6 1.0 1 1.0 2 0.3
162. LOAD COMB 105 1.42(DL1 + DL2) + 0.5LL1 + 0.5LLR + 1.0LL2 + 1.0EX - 0.3EZ
163. 3 1.42 4 1.42 5 0.5 7 0.5 6 1.0 1 1.0 2 -0.3
164. LOAD COMB 106 1.42(DL1 + DL2) + 0.5LL1 + 0.5LLR + 1.0LL2 - 1.0EX + 0.3EZ
165. 3 1.42 4 1.42 5 0.5 7 0.5 6 1.0 1 -1.0 2 0.3
166. LOAD COMB 107 1.42(DL1 + DL2) + 0.5LL1 + 0.5LLR + 1.0LL2 - 1.0EX - 0.3EZ
167. 3 1.42 4 1.42 5 0.5 7 0.5 6 1.0 1 -1.0 2 -0.3
168. LOAD COMB 108 1.42(DL1 + DL2) + 0.5LL1 + 0.5LLR + 1.0LL2 + 1.0EZ + 0.3EX
169. 3 1.42 4 1.42 5 0.5 7 0.5 6 1.0 1 0.3 2 1.0
170. LOAD COMB 109 1.42(DL1 + DL2) + 0.5LL1 + 0.5LLR + 1.0LL2 + 1.0EZ - 0.3EX
171. 3 1.42 4 1.42 5 0.5 7 0.5 6 1.0 1 -0.3 2 1.0
172. LOAD COMB 110 1.42(DL1 + DL2) + 0.5LL1 + 0.5LLR + 1.0LL2 - 1.0EZ + 0.3EX
173. 3 1.42 4 1.42 5 0.5 7 0.5 6 1.0 1 0.3 2 -1.0
174. LOAD COMB 111 1.42(DL1 + DL2) + 0.5LL1 + 0.5LLR + 1.0LL2 - 1.0EZ - 0.3EX
175. 3 1.42 4 1.42 5 0.5 7 0.5 6 1.0 1 -0.3 2 -1.0
176. LOAD COMB 112 1.12(DL1 + DL2) + 1.0EX + 0.3EZ
177. 3 1.12 4 1.12 1 1.0 2 0.3
178. LOAD COMB 113 1.12(DL1 + DL2) + 1.0EX - 0.3EZ
179. 3 1.12 4 1.12 1 1.0 2 -0.3
180. LOAD COMB 114 1.12(DL1 + DL2) - 1.0EX + 0.3EZ
181. 3 1.12 4 1.12 1 -1.0 2 0.3
182. LOAD COMB 115 1.12(DL1 + DL2) - 1.0EX - 0.3EZ
183. 1 4.0 1 1.0 -1 2.0 -0.3
184. LOAD COMB 116 1.12(DL1 + DL2) + 1.0EZ + 0.3EX
185. 3 1.12 4 1.12 1 0.3 2 1.0
186. LOAD COMB 1161 1.12(DL1 + DL2) + 1.0EZ - 0.3EX
187. 3 1.12 4 1.12 1 0.3 2 1.0
188. LOAD COMB 117 1.12(DL1 + DL2) - 1.0EZ + 0.3EX
189. 3 1.12 4 1.12 1 0.3 2 -1.0
190. LOAD COMB 118 1.12(DL1 + DL2) - 1.0EZ - 0.3EX
191. 3 1.12 4 1.12 1 -0.3 2 -1.0
192. LOAD COMB 119 0.68(DL1 + DL2) + 1.0EX + 0.3EZ
193. 3 0.68 4 0.68 1 1.0 2 0.3
194. LOAD COMB 120 0.68(DL1 + DL2) + 1.0EX - 0.3EZ
195. 3 0.68 4 0.68 1 1.0 2 -0.3
196. LOAD COMB 121 0.68(DL1 + DL2) - 1.0EX + 0.3EZ
197. 3 0.68 4 0.68 1 -1.0 2 0.3
198. LOAD COMB 122 0.68(DL1 + DL2) - 1.0EX - 0.3EZ
199. 3 0.68 4 0.68 1 -1.0 2 -0.3
200. LOAD COMB 123 0.68(DL1 + DL2) + 1.0EZ + 0.3EX
201. 3 0.68 4 0.68 2 1.0 1 0.3
202. LOAD COMB 124 0.68(DL1 + DL2) + 1.0EZ - 0.3EX
203. 3 0.68 4 0.68 2 1.0 1 -0.3
204. LOAD COMB 125 0.68(DL1 + DL2) - 1.0EZ + 0.3EX
205. 3 0.68 4 0.68 2 -1.0 1 0.3
206. LOAD COMB 126 0.68(DL1 + DL2) - 1.0EZ - 0.3EX
207. 3 0.68 4 0.68 2 -1.0 1 -0.3
208. PERFORM ANALYSIS

D:\Others\Gerbon\Bahay Toro QC\STAAD\Two Storey Residential House (Bahay Toro QC).anl Page 5 of 7
Saturday, 27 April 2024 9:06 am

STAAD SPACE -- PAGE NO. 6

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 30 NUMBER OF MEMBERS 44


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 9

Using 64-bit analysis engine.

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 20/ 9/ 42 DOF


TOTAL PRIMARY LOAD CASES = 8, TOTAL DEGREES OF FREEDOM = 126
TOTAL LOAD COMBINATION CASES = 27 SO FAR.
SIZE OF STIFFNESS MATRIX = 6 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.1/ 333335.9 MB

**WARNING- NO RIGID FLOOR DIAPHRAGM IS PRESENT IN THE MODEL.


DEC AND ACC FACTORS ARE IGNORED.
**WARNING- NO RIGID FLOOR DIAPHRAGM IS PRESENT IN THE MODEL.
DEC AND ACC FACTORS ARE IGNORED.

**WARNING: IF THIS UBC/IBC ANALYSIS HAS TENSION/COMPRESSION


OR REPEAT LOAD OR RE-ANALYSIS OR SELECT OPTIMIZE, THEN EACH
UBC/IBC CASE SHOULD BE FOLLOWED BY PERFORM ANALYSIS & CHANGE.

***********************************************************
* *
* X DIRECTION : Ta = 0.280 Tb = 0.137 Tuser = 0.000 *
* T = 0.137, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.0353 x 203.31 = 7.18 KN *
* *
***********************************************************

***********************************************************
* *
* Z DIRECTION : Ta = 0.280 Tb = 0.212 Tuser = 0.000 *
* T = 0.212, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.0353 x 203.31 = 7.18 KN *
* *
***********************************************************

209. FINISH

D:\Others\Gerbon\Bahay Toro QC\STAAD\Two Storey Residential House (Bahay Toro QC).anl Page 6 of 7
Saturday, 27 April 2024 9:06 am

STAAD SPACE -- PAGE NO. 7

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= APR 27,2024 TIME= 9: 3:13 ****

************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://www.bentley.com/en/support/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2017 Bentley Systems, Inc. *
* http://www.bentley.com *
************************************************************

D:\Others\Gerbon\Bahay Toro QC\STAAD\Two Storey Residential House (Bahay Toro QC).anl Page 7 of 7