Professional Documents
Culture Documents
Thermal-Magnetic Circuit Breakers 3600/3900: Description
Thermal-Magnetic Circuit Breakers 3600/3900: Description
Description
Typical applications
3600 3900
1
Process control systems, instrumentation, communications systems, standard type low-resistance type
rail vehicles.
Technical data
Ordering information
For further details please see: http://www.e-t-a.de/ti_e
Type No.
Voltage rating AC 240 V, 50/60 Hz; DC 65 V
3600 standard version with shunt tap terminal -3
(UL: AC 250 V; DC 65 V)
3900 low-resistance version
Terminal design Current rating range 3600: 0.05...16 A
P10 blade terminals 6.3-0.8 (QC .250) 3900: 0.05...10 A
Auxiliary contacts (3900: intermediate position as standard) Auxiliary circuit 1 A, AC 240 V / DC 65 V
Si with blade terminals 6.3-08,one each NO/NC, min. 10 V/10 mA
Current ratings
Typical life 5,000 operations at 1 x IN, inductive
0.05...16 A (type 3600)
5,000 operations at 2 x IN, resistive
0.05...10 A (type 3900)
Ambient temperature -30...+60 °C (-22...+140 °F)
3600 - P10 - Si - 10 A ordering example Insulation co-ordination rated impulse pollution
(IEC 60664 and 60664 A) withstand voltage degree
The exact part number required can be built up from the table of choices shown
2.5 kV 2
above. Ordering references for optional features should be omitted if not required.
reinforced insulation in operating area
Please be informed that we have minimum ordering quantities to be Dielectric strength
observed. (IEC 60664 and 60664A) test voltage
operating area AC 3,000 V
main/aux. circuit AC 1,500 V
aux. circuit 4-5/6-7 AC 840 V
Preferred types
Insulation resistance >100 MΩ (DC 500 V)
Interrupting capacity Icn 3600 3900
Preferred types Standard current ratings (A) 0.05...0.8 A 0.05...0.2 A self-limiting
0.5 1 2 4 8 10 16 1...2 A 0.3...2 A 200 A
2.5...16 A 2.5...10 A 400 A
3600-P10-Si- x x x x x x x
Interrupting capacity IN UN
3900-P10-Si- x x x x
(UL 1077) 0.05...16 A AC 250 V 1,000 A
type 3600: 0.05...16 A DC 80 V 1,000 A
Degree of protection operating area IP40
Standard current ratings and typical internal resistance values (IEC 60529/DIN 40050) terminal area IP00
Vibration 5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
Current Internal resistance Current Internal resistance to IEC 60068-2-6, test Fc
ratings (Ω) ratings (Ω) 10 frequency cycles/axis
(A) (A)
3600 3900 3600 3900 Shock 25 g (11 ms) to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist
0.05 447 211 3 0.19 0.054
to IEC 60068-2-11, test Ka
0.1 131 48 4 0.090 0.035
Humidity 240 hours at 95 % RH
0.2 40 12.4 5 0.061 0.025 to IEC 60068-2-78, test Cab
0.3 19.3 5.4 6 0.041 ≤ 0.02 Mass approx. 45 g
0.4 10.4 3.1 7 0.034 ≤ 0.02
0.5 7.1 2.0 8 ≤ 0.02 ≤ 0.02
0.6 4.3 1.32 10 ≤ 0.02 ≤ 0.02
0.8 2.5 0.76 12 ≤ 0.02
1 1.67 0.49 14 ≤ 0.02
1.5 0.61 0.21 15 ≤ 0.02
2 0.38 0.101 16 ≤ 0.02
2.5 0.24 0.078
1944 www.e-t-a.de 1
Thermal-Magnetic Circuit Breakers 3600/3900
-P10-Si ø11.5
with shunt terminal (standard)
.453 ø6.5 ø8.5 and auxiliary contacts (-Si) only 3600
OFF
ON
3 3 4 6
.197
.079
5
2
2.01
I>
51
.748
1
19
2 2
1 4 6 3 7 5 2
.394
10
Installation drawing
6.8
.268 blade terminals
6 x 6.8 = 40.8 DIN 46244-A6.3-0.8
6 x .268 = 1.61 (QC .250)
operating area
43 (reinforced insulation)
current rating in A
1.69
13 20
.512 .787
11.5
.453
2
50
.335
8.5
.787
1.97
20
1.50
38
Terminal design -P10
.079
2
1 4 6 3 7 5 2
1 3 2
12.5
mounting area
.492
10 10 10
1 1 1
2 www.e-t-a.de 1944
Thermal-Magnetic Circuit Breakers 3600/3900
Accessories
.394
10
6.3
depth .248
.335
10 mm
1
10
8.5
(.394 in.) .394
1 2(k) 1 2(k)
1.02
25.8
12 12
33.3
11 11
1.31
41.3
1.63
24 24
.055
1.4
.197
45.8
1.80
23 23
5
2(i) 2(i)
80 12.5
.256
6.5
3.15 .492
symmetrical rail
EN 50022-35x7.5 G-profile
polarization recess adapter X20040901 EN 50035-G32
Module 17plus
For technical data see section Power Distribution Systems
Sockets
slot for fitting labels from 17-P70-Si 17-P70-Si-20025
Phoenix, Weidmüller, Wieland (up to 16 A max. load) mounted with adapter
Retaining clip Y 300 581 11 to special order.
.394
10
2.8
51
depth .110
.335
10 mm 10
8.5
1 2(k) 1 2(k)
1.02
25.8
12 12
33.3
11 11
1.31
17 plus
57
41.3
1.63
24 24
.055
1.4
.197
42,5
45.8
1.80
23 23
47
2(i)
5 2(i)
80 12.5
.256
6.5
3.15 .492
14
12.2
2.2
test socket
2.1
Line
1.1
12.1
14
Approvals
2.52
1.97
2.26
2.52
1.97
2.26
57.4
57.4
64
64
50
50
1944 www.e-t-a.de 3
Thermal-Magnetic Circuit Breakers 3600/3900
Accessories
1 .079
2
female
connector
M4 Cu rail, tin-plated
.394
10
7 12.8
.276 .504 pressure-relief joint
154.8 (1.1 mm (.043 in.)
6.09 thick constriction)
Extraction tool
Y 301 398 02
56
2.21
1.81
46
1
.295
7.5
.039
.079
.075
1.9
0.5
.079
2
.020
12.5 8.5
.492 60.4 .335
7.3 2.38
.287 50
1.97
M4
8
16.5 20 All dimensions without tolerances are for reference only. In the interest of improved design,
.650 .787 performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
4 www.e-t-a.de 1944