TESTS & RUN-IN

SM Rapidtech Ltd. Service Engineers carried out a test run upon overhaul completion, witnessed by the …....

THE A/E NO LOAD PROCEDURE

After each run, crankcase were open for inspection, conrod free side movement, and bearing temperatures confirmation.
o o
Runing time, min RPM Main bearings average temperature, C Crank pin bearings average temperature, C
1 900 41 42
Runing time, min RPM Main bearings average temperature, o C o
Crank pin bearings average temperature, C
2
Runing time, min RPM Main bearings average temperature, o C o
Crank pin bearings average temperature, C
5
Runing time, min RPM Main bearings average temperature, o C o
Crank pin bearings average temperature, C
15
Runing time, min RPM Main bearings average temperature, o C Crank pin bearings average temperature, o C
30
Runing time, min RPM Main bearings average temperature, o C Crank pin bearings average temperature, o C
60 900 60 62
During one hour of idle running all parameters confirmed within the operating range.

Photo Photo Photo

Picture 1 Picture 2 Picture 3

AMS SAFTY SHUT DOWN ALARMS CONFIRMATION

Following alarms were comfirmed:


· Over speed shout down: 1030 rpm
· Lube oil low pressure: 3.0 bar
· High temperature HT: 95˚C

Photo Photo Photo


Picture 1 Picture 2 Picture 3

1/1 Designed by Technical Department