TECHNICAL SPECIFICATIONS:
• Painted metallic framework with fore panel of insulating
material
• Quick connections via safety leads and terminals (Ø 4 mm)
• 1 automatic microprocessor controller of power factor, with
rated voltage of 380-415 V – 50-60 Hz
- ammeter input with forward current up to 5 A (sensitivity
MS
range 0, 125 … 6 A)
- setting power factor: 0.8 ind … 0.8 cap., reconnection time:
5 … 240 s
- sensitivity range: 5…600 s/step
- 5 relay outputs with contacts of 5 A – 250 Vac
- setting parameters manually from display-assisted keyboard
• 2 multi-function instruments; auxiliary power supply 115-
230V; LCD display, 128x80 pixel
- measurements of voltages, currents, active, reactive and
apparent powers, and power factor in single-phase and
three-phase systems
- accuracy rating for currents and voltages: ± 1%
- measuring range: 5 A – 850 V max.
• 1 four-pole rotary switch of operation – 16 A – 400 V
• 1 set of three fuse holders with gl-type fuses 10.3x38 of 6 A
• 1 pair of fuse holders with gl-type fuses 10.3x38 of 2 A
• 1 fuse holder with gl-type fuse 10.3x38 of 4 A
ELECTRICAL ENGINEERING
POWER SUPPLY:
Single-phase 230 V - 50-60 Hz - 50 VA
SUPPLIED ACCESSORIES: Three-phase 3 x 400 V - 50-60 Hz -3 kVA