Professional Documents
Culture Documents
1 .2 MW GM BOM With Costing Sheet
1 .2 MW GM BOM With Costing Sheet
Material Make
1 Solar Module Jinko
2 Inverter SunGrow
3 Structure Design
Structure Column
members are hot dip
galvanized to min of 80
4 HotDip & SS
microns remaining
Structure members are
Galvalume
6 Fastners SS
7 Transformer Essnar
8 AUX Transformer Everwin
Future Engineering
9 Solar LT Panel
Solutions
Future Engineering
10 AC- Combiner Box
Solutions
Future Engineering
11 Bus duct
Solutions
"Breaker type - VCB : 11kV, 630Amp, Eletrical oprated Draw
PT, Fixed /draw out type, 1
Cast Resin CTs :- 1 set, Fixed Type, 100/5-5A, Dual Co
STR:25KA/1Se
12 VCB Panel
directional M
Protection relay : 1 No. Microprocessor base numerical relay
no. Master Trip Relay, Electromechanical relays
Internal UPS system, Hoot
13 DCDB
14 DC CABLES Siechem
15 AC cable Polycab
Indelec
Indelec
Indelec
Indelec
Indelec
Indelec
17
EARTHING & EARTHING CABLE
Indelec
Indelec
Indelec
Indelec
18 Chamber Concreate
Cable Connector Stabuli
19 YConnector Stabuli
Panel Connector Stabuli
20 Insulation Tape Reputed
21 Caution tape Reputed
22 Route Marker Reputed
23 LUGS 3D/DOWELL/BRAC CO / Reputed
24 Foam PU Form
25 Lan cable cat 6
Reputed
26 Module Cleaning System
Reputed
Reputed
Reputed
28 Frencing
29 SLDC
30 Frecing GI Material
Installation
Bifacial Solar Module JK570N-72HL4 with Specification
Bypass Diodes PID Free & UV Resistant, Capacity-
570 WpType 2 SPD for both DC & AC , Model : SG
320 kW, IP66 and C5 Protection MC4 Connectors,
STAAD REPORT (Independently verified by320HX 3rd party), PILE CALCULATION & BOM FOR
14x2
1mm TABLE AND 2 ITERATIONS
Thick 550Mpa Galvalium/PreINCLUDED.
Galvanaisd, Bracing- Min 2mm Thick 250Mpa Hot-Dip
Galvanized and Purlin
SS304 Rafter
HEX Connector-
M12X35 MM BOLTMin with
4MM1 Thick
Nut, 1 250Mpa Hot-Dip
S/W , 2 P/W as Galvanized
perIS1363/IS2016 Standard
SS304 HEX M10X35MM BOLT with 1 Nut, 1 S/W , 2 P/W as per IS1363/IS2016 Standard
SS304 HEX M4X20MM SS304BOLT with 1 Nut, M8X25
ALLEN(SHCS) 1 S/W ,1MM
StarBOLT
Washer 2 P/W
with as per
1 Nut, IS1363/IS2016
1 S/W , Standa
1 P/W as per DIN912/ IS1363/IS2016 Standard
SS304 HEX M8X20MM BOLT with 1 Nut, 1 S/W , 2 P/W as per IS1363/IS2016 Standard
Electroplate GI 4.6 Grade M6 X 30 MM Bolt with Nut, 1 S/W,2 P/W
SS304 M8*25mm
2.5% steps, Two winding with Copper materials , confirming to IS 2026. Efficiency at 75 Deg. C. at
15 KVA, 800/415 V (LV as per theUPF @ 100%
inverter) Load50Hz,
, Dyn11, 99.0%.
ONAN, OCTC with +/- 5% @ 2.5%
steps, dry type
2mm thickness frame,1.6mm copper
Door, wounded
Gland transformer
plate shall be 2mmconfirming tomounting
thickness & IS 2026. plate shall be
2mm thickness
IP rating: IP 65."
Fine wire strands annealed tinned copper conductor, flexible class 5 as per IEC 60228:2004 or
latest, 1C x 6 SQ.MM, 1500V, XLPO,TYPE-1
CU CABLE (DC Cable), Max. permissible operating voltage DC 1800 V, Test voltage AC 6,5 kV,
insulation & outer sheath shall be Electron beam cross linked co-polymer, halogen free XLPO
(POLYOLEFIN)
1.9/3.3kV(E), 3C X 120 sq.mm, XLPE, Al, Ar.,Cable (Inverter to ACDB)
4Sq.mm*4C cable
ESE Type Lightning Arrestor with GI Mast (Overall Height- 6.5 Mtr), Area of coverage is 107 mtr
radius. Along with tension wire support on 3 sides with accessories
Lightining Arrestor
RCC CHAMBER
800 V, Test voltage AC 6,5 kV, Mtr 11,000 51 555,500 49,995 49,995
ymer, halogen free XLPO
0 212,400 Reyna
0 655,490 Vibrant
0 104,725
0 390,698
0 72,924
0 963
0 12,156
0 7,623
0 9,558
0 57,820
0 3,983
Asha Enterpises
0 1,947
0 5,753
15,349 100,621
3,600 23,600
3,582 23,481
14,328 93,928
2,702 17,714
205 1,345
Indelec
2,016 13,216
162 1,062
10,800 70,800
360 2,360
0 58,410 Vidhya Eneterprises
0 97,940
0 30,090 Nordic
0 11,564
0 8,880
Veer Power
0 354
0 3,540 Future Engineering
0 33,426 Veer Power
0 4,956 Veer Power
0 16,555
0 82,956
ALS PIPE
0 11,009